Category:Graphics incl Charts and Tables
MONTHYEARML23095A3722023-04-0505 April 2023 2023 Updated Final Safety Analysis Report, Technical Specification Bases and Technical Requirements Manual Changes Transmittal ML17150A2562017-06-0505 June 2017 Entergy Fleet - 2017 Onsite Insurance Submittal Review for Entergy Operations, Inc., and Entergy Nuclear Operations, Inc. (CAC No. TM3058) JAFP-16-0110, Correction to 2014 Annual Radioactive Effluent Release Report2016-06-29029 June 2016 Correction to 2014 Annual Radioactive Effluent Release Report JAFP-16-0060, James a Fitzpatrick - Extension to Commitments Made in Response to March 12, 2012, Information Request Pursuant to 10 CFR 50.54(f) Regarding Recommendation 9.3, Emergency Communication and Staffing Assessments2016-04-14014 April 2016 James a Fitzpatrick - Extension to Commitments Made in Response to March 12, 2012, Information Request Pursuant to 10 CFR 50.54(f) Regarding Recommendation 9.3, Emergency Communication and Staffing Assessments ML16056A1392016-03-11011 March 2016 Correction to the U.S. Nuclear Regulatory Commission Analysis of Licensees' Decommissioning Funding Status Reports ML15238B5372015-09-0404 September 2015 Interim Staff Response to Reevaluated Flood Hazards Submitted in Response to 10 CFR 50.54(f) Information Request - Flood-Causing Mechanism Reevaluation ML15229A0232015-08-13013 August 2015 Tables 1 and 2 JAFP-15-0017, J.A. Fitzpatrick - Response to Regulatory Issue Summary 2014-132015-02-0202 February 2015 J.A. Fitzpatrick - Response to Regulatory Issue Summary 2014-13 JAFP-14-0145, Supplemental Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Flooding Aspects of Recommendations 2.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident2014-12-19019 December 2014 Supplemental Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Flooding Aspects of Recommendations 2.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident JAFP-10-0088, Submittal of Corrections to the 2004, 2005, 2006, 2007, and 2008 Annual Radioactive Effluent Release Reports2010-07-15015 July 2010 Submittal of Corrections to the 2004, 2005, 2006, 2007, and 2008 Annual Radioactive Effluent Release Reports ENOC-08-00040, Commitment Update Relating to Application for Order Approving Indirect Transfer of Control of Licenses2008-07-28028 July 2008 Commitment Update Relating to Application for Order Approving Indirect Transfer of Control of Licenses ML0732400092007-11-19019 November 2007 JAFNPP SEIS Web Reference - NOAA 2004b - Thunderstorms and Wind Events ENOC-07-00036, Entergy Operations, Inc. - Supplemental Information in Support of Application for Order Approving Indirect Transfer of Control of Licenses2007-10-31031 October 2007 Entergy Operations, Inc. - Supplemental Information in Support of Application for Order Approving Indirect Transfer of Control of Licenses ML0728203072007-10-11011 October 2007 Electronic Distribtion Initiative Letter, Licensee List, Electronic Distribution Input Information, Division Plant Mailing Lists ML0733004352007-08-17017 August 2007 Comments from JAFNPP Regarding Safety Evaluation Report with Open Items ML0705804642007-05-25025 May 2007 Audit Summary for the JAFNPP LRA Safety Site Audits ML0701603912007-01-16016 January 2007 JAFNPP - SEIS Web Reference - Great Lakes: Lake Ontario ML0710004712006-03-0909 March 2006 Great Lakes Atlas Fact Sheet #1 ML0701602092005-12-31031 December 2005 JAFNPP - SEIS Web Reference - Schaner 2005, Pelagic Planktivores, NYSDEC Lake Ontario Annual Report 2005 ML0701603982005-12-31031 December 2005 JAFNPP - SEIS Web Reference - Mnr Fish Stocking Summary 2005 ML0535703362005-12-0505 December 2005 Geographical, Environmental and Siting Information Minority and Low Income Data, Pilgrim and FitzPatrick Sites from 2000 Census ML0529001372005-10-17017 October 2005 Transformer Data - for Information Only Press Release-I-05-039, NRC Begins Special Inspection at James A. Fitzpatrick Nuclear Plant2005-07-0707 July 2005 Press Release-I-05-039: NRC Begins Special Inspection at James A. Fitzpatrick Nuclear Plant ML0701602162004-12-31031 December 2004 JAFNPP - SEIS Web Reference - O'Gorman Et Al 2005 JAFP-04-0190, In-Vessel Visual Inspection Summary Report 2004 Refuel Outage (Reload 16/Cycle 17)2004-12-15015 December 2004 In-Vessel Visual Inspection Summary Report 2004 Refuel Outage (Reload 16/Cycle 17) JAFP-05-0179, Enclosure 13, Calculation JAF-CALC-ELEC-02610 125VDC B Station Battery Sizing & Voltage Drop Revision 2, Appendix 4, Page 2 of 2, SBO2003-05-16016 May 2003 Enclosure 13, Calculation JAF-CALC-ELEC-02610 125VDC B Station Battery Sizing & Voltage Drop Revision 2, Appendix 4, Page 2 of 2, SBO ML0701602221999-10-31031 October 1999 JAFNPP - SEIS Web Reference - Boyd and Biberhofer 1999 2023-04-05
[Table view] Category:Letter type:JAFP
MONTHYEARJAFP-24-0051, Reply to Preliminary White Finding and Apparent Violation in NRC Inspection Report 05000333/2024011; EA-24-0882024-10-0303 October 2024 Reply to Preliminary White Finding and Apparent Violation in NRC Inspection Report 05000333/2024011; EA-24-088 JAFP-24-0046, Request for Enforcement Discretion for Technical Specification (TS) 3.3.2.1 Control Rod Block Instrumentation2024-09-25025 September 2024 Request for Enforcement Discretion for Technical Specification (TS) 3.3.2.1 Control Rod Block Instrumentation JAFP-24-0047, License Amendment Request – Temporary Addition to TS 3.3.2.1 Condition C, Control Rod Block Instrumentation to Support Upgrade to Rod Worth Minimizer Software2024-09-25025 September 2024 License Amendment Request – Temporary Addition to TS 3.3.2.1 Condition C, Control Rod Block Instrumentation to Support Upgrade to Rod Worth Minimizer Software JAFP-24-0045, Supplemental Information for License Amendment Request to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4, and Administrative Changes to the Technical Specifications2024-09-20020 September 2024 Supplemental Information for License Amendment Request to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4, and Administrative Changes to the Technical Specifications JAFP-24-0044, Core Operating Limits Report Cycle 272024-09-16016 September 2024 Core Operating Limits Report Cycle 27 JAFP-24-0043, Revision to Commitment Relating to Resolution of Anchor Darling Double Disc Gate Valve Part 21 Issues2024-09-12012 September 2024 Revision to Commitment Relating to Resolution of Anchor Darling Double Disc Gate Valve Part 21 Issues JAFP-24-0034, 10 CFR 50.46 Annual Report2024-07-31031 July 2024 10 CFR 50.46 Annual Report JAFP-24-0036, Supplement to License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis2024-07-29029 July 2024 Supplement to License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis JAFP-24-0033, Response to Request for Information Pertaining to a Licensed Operator Positive Fitness-For-Duty Test2024-07-23023 July 2024 Response to Request for Information Pertaining to a Licensed Operator Positive Fitness-For-Duty Test JAFP-24-0027, EDG Lube Oil Check Valve Bonnet Cap Leak Due to Failed Gasket2024-06-24024 June 2024 EDG Lube Oil Check Valve Bonnet Cap Leak Due to Failed Gasket JAFP-24-0026, Supplement to License Amendment Request to Modify Technical Specification Surveillance Requirement (SR) 3.4.3.1 Safety Relief Valves (Srvs) Setpoint Lower Tolerance2024-06-12012 June 2024 Supplement to License Amendment Request to Modify Technical Specification Surveillance Requirement (SR) 3.4.3.1 Safety Relief Valves (Srvs) Setpoint Lower Tolerance JAFP-24-0023, 2023 Annual Radiological Environmental Operating Report2024-05-0909 May 2024 2023 Annual Radiological Environmental Operating Report JAFP-24-0020, 2023 Annual Radioactive Effluent Release Report2024-04-25025 April 2024 2023 Annual Radioactive Effluent Release Report JAFP-24-0019, 2023 REIRS Transmittal of NRC Form 52024-04-18018 April 2024 2023 REIRS Transmittal of NRC Form 5 JAFP-24-0014, Response to Request for Additional Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis2024-03-25025 March 2024 Response to Request for Additional Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis JAFP-24-0010, Response to Request for Additional Information for License Amendment Request to Modify Technical Specification Surveillance Requirement (SR) 3.4.3.1 Safety Relief Valves (S/Rvs) Setpoint Lower Tolerance2024-02-29029 February 2024 Response to Request for Additional Information for License Amendment Request to Modify Technical Specification Surveillance Requirement (SR) 3.4.3.1 Safety Relief Valves (S/Rvs) Setpoint Lower Tolerance JAFP-24-0009, Response to Request for Additional Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis2024-02-28028 February 2024 Response to Request for Additional Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis JAFP-23-0065, License Amendment Request to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4, and Administrative Changes to the Technical Specifications2023-12-14014 December 2023 License Amendment Request to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4, and Administrative Changes to the Technical Specifications JAFP-23-0069, Supplemental Response to Part 73 Exemption Request – Withdrawal of Request for Exemption from 10 CFR 73, Subpart B, Preemption Authority Requirements2023-12-0707 December 2023 Supplemental Response to Part 73 Exemption Request – Withdrawal of Request for Exemption from 10 CFR 73, Subpart B, Preemption Authority Requirements JAFP-23-0066, for James A. Ftizpatrick Nuclear Power Plant, Misaligned Spacer Prevented Tie Breaker Closing Coil Armature Operation on a Magne-Blast for EDG a Subsystem2023-12-0101 December 2023 for James A. Ftizpatrick Nuclear Power Plant, Misaligned Spacer Prevented Tie Breaker Closing Coil Armature Operation on a Magne-Blast for EDG a Subsystem JAFP-23-0057, and Independent Spent Fuel Storage Installation - Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-11-22022 November 2023 and Independent Spent Fuel Storage Installation - Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation JAFP-23-0064, Emergency Plan Document Revision2023-11-15015 November 2023 Emergency Plan Document Revision JAFP-23-0063, Registration of Spent Fuel Cask Use2023-11-13013 November 2023 Registration of Spent Fuel Cask Use JAFP-23-0059, Registration of Spent Fuel Cask Use2023-10-24024 October 2023 Registration of Spent Fuel Cask Use JAFP-23-0050, Physical Security Plan, Revision 242023-08-31031 August 2023 Physical Security Plan, Revision 24 JAFP-23-0048, Supplemental Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis2023-08-31031 August 2023 Supplemental Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis JAFP-23-0047, Correction to the 2022 Annual Radioactive Effluent Release Report2023-08-30030 August 2023 Correction to the 2022 Annual Radioactive Effluent Release Report JAFP-23-0040, License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis2023-08-0303 August 2023 License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis JAFP-23-0043, 10 CFR 50.46 Annual Report2023-07-31031 July 2023 10 CFR 50.46 Annual Report JAFP-23-0038, License Amendment Request to Modify Technical Specification Surveillance Requirement (SR) 3.4.3.1 Safety Relief Valves (S/Rvs) Setpoint Lower Tolerance2023-07-28028 July 2023 License Amendment Request to Modify Technical Specification Surveillance Requirement (SR) 3.4.3.1 Safety Relief Valves (S/Rvs) Setpoint Lower Tolerance JAFP-23-0033, License Amendment Request - Technical Specifications (TS) Section 3.3.1.2, Source Range Monitors (SRM) Instrumentation2023-06-28028 June 2023 License Amendment Request - Technical Specifications (TS) Section 3.3.1.2, Source Range Monitors (SRM) Instrumentation JAFP-23-0025, 2022 Annual Radiological Environmental Operating Report2023-05-10010 May 2023 2022 Annual Radiological Environmental Operating Report JAFP-23-0023, 2022 Annual Radioactive Effluent Release Report2023-04-27027 April 2023 2022 Annual Radioactive Effluent Release Report JAFP-23-0010, 2022 REIRS Transmittal of NRC Form 52023-03-20020 March 2023 2022 REIRS Transmittal of NRC Form 5 JAFP-23-0008, Supplement to Inservice Inspection Summary Report Cycle 252023-02-22022 February 2023 Supplement to Inservice Inspection Summary Report Cycle 25 JAFP-22-0053, Inservice Inspection Summary Report Cycle 252022-12-20020 December 2022 Inservice Inspection Summary Report Cycle 25 JAFP-22-0046, Core Operating Limits Report Cycle 262022-10-17017 October 2022 Core Operating Limits Report Cycle 26 JAFP-22-0040, 10 CFR 50.46 Annual Report2022-07-29029 July 2022 10 CFR 50.46 Annual Report JAFP-22-0033, Core Operating Limits Report Mid-Cycle 252022-06-23023 June 2022 Core Operating Limits Report Mid-Cycle 25 JAFP-22-0032, Response to Request for Additional Information for James A. FitzPatrick Nuclear Power Plant to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b..2022-06-16016 June 2022 Response to Request for Additional Information for James A. FitzPatrick Nuclear Power Plant to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b.. JAFP-22-0030, Oswego County and New York State Participation in the Emergency Plan2022-05-13013 May 2022 Oswego County and New York State Participation in the Emergency Plan JAFP-22-0029, 2021 Annual Radiological Environmental Operating Report2022-05-11011 May 2022 2021 Annual Radiological Environmental Operating Report JAFP-22-0028, 2021 Annual Radioactive Effluent Release Report2022-04-27027 April 2022 2021 Annual Radioactive Effluent Release Report JAFP-22-0026, 2021 REIRS Transmittal of NRC Form 52022-04-0707 April 2022 2021 REIRS Transmittal of NRC Form 5 JAFP-22-2020, Supplemental Information No. 1 for James A. FitzPatrick Nuclear Power Plant to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b. and 10CFR 50.69, Risk-Info2022-03-0404 March 2022 Supplemental Information No. 1 for James A. FitzPatrick Nuclear Power Plant to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b. and 10CFR 50.69, Risk-Informed JAFP-22-0017, Amendments to Indemnity Agreements2022-02-15015 February 2022 Amendments to Indemnity Agreements JAFP-22-0007, Summary of Changes to Exelon Generation Company, LLC, Quality Assurance Topical Report, NO-AA-10, and Decommissioning Quality Assurance Program, NO-DC-102022-01-31031 January 2022 Summary of Changes to Exelon Generation Company, LLC, Quality Assurance Topical Report, NO-AA-10, and Decommissioning Quality Assurance Program, NO-DC-10 JAFP-22-0010, Supplemental Information in Response to Order Consenting to License Transfers and Approval of Draft Conforming License Amendments2022-01-24024 January 2022 Supplemental Information in Response to Order Consenting to License Transfers and Approval of Draft Conforming License Amendments JAFP-22-0008, Response to Request for Supplemental Information by the Office of Nuclear Reactor Regulation to Support Review of a License Amendment Request to Eliminate Selected Response Time Testing for Reactor Protection System and Primary2022-01-14014 January 2022 Response to Request for Supplemental Information by the Office of Nuclear Reactor Regulation to Support Review of a License Amendment Request to Eliminate Selected Response Time Testing for Reactor Protection System and Primary JAFP-21-0093, Propose Change to Eliminate Selected Response Time Testing for Reactor Protection System and Primary Containment Isolation Instrumentation2021-10-18018 October 2021 Propose Change to Eliminate Selected Response Time Testing for Reactor Protection System and Primary Containment Isolation Instrumentation 2024-09-25
[Table view] |
Text
Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.
James A. FitzPatrick NPP P.O. Box 110 Lycoming, NY 13093 Tel 315-342-3840 Brian R. Sullivan Site Vice President - JAF JAFP-14-0145 December 19, 2014 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Subject:
Supplemental Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Flooding Aspects of Recommendations 2.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 License No. DPR-059
Reference:
- 1. NRC letter, Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3, and 9.3, of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, ML12053A340, dated March 12, 2012
- 2. Entergy letter, Flooding Walkdown Report - Entergys Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Flooding Aspects of Recommendation 2.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, JAFP-12-0135, dated November 27, 2012
- 3. Entergy Letter, Update to Response to NRC 10 CFR 50.54(f) Request for Information Regarding Near-Term Task Force Recommendation 2.3, Flooding - Review of Available Physical Margin (APM) Assessments, dated January 30, 2014, JAFP-14-0010
- 4. NEI letter, Generic Template for Closure of Flooding Design Basis Walkdown Restricted Access Items, APC 13-13, dated May 13, 2013
- 5. Entergy letter, Extension to Commitment in Flooding Walkdown Report for Restricted Access Equipment, JAFP-14-0121, dated October 30, 2014
Dear Sir or Madam:
On March 12, 2012, the Nuclear Regulatory Commission (NRC) issued Reference 1 to all power reactor licensees and holders of construction permits in active or deferred status. Enclosure 4 of Reference 1 requested that each licensee perform flood protection walkdowns and report the results. James A. FitzPatrick Nuclear Power Plant (JAF) submitted a Flooding Walkdown Report by Reference 2.
JAFP-14-0145 Page 2 of 2 Reference 2 identified items where restricted access prevented walkdown of certain flood protection features. Walkdowns of the restricted access items have been completed with the exception of the two perimeter drain pumps which have been reclassified as inaccessible features per the guidance provided in NEI 12-07 (Rev. 0-A) "Guidelines for Performing Verification Walkdowns of Plant Flood Protection Features" section 3.6.
The results are provided in the attachment to this letter. This submittal closes all the open items identified in Reference 2.
The attachment to this letter provides a list of the restricted access items inspected as well as those items reclassified as inaccessible, their respective disposition, and any action planned or taken. As a result of the inspections:
- There are no additional deficiencies found in the supplemental walkdown.
- No temporary measures were required as a result of the completed inspections.
- The restricted access item inspected was within the plant maintenance and monitoring programs.
- Available physical margin (APMs) were evaluated and documented in the walkdown record forms for each applicable item inspected in accordance with NEI 12-07.
- Two of the restricted access items were reclassified as inaccessible.
This letter contains no new regulatory commitments. If you have any questions regarding this report, please contact Chris M. Adner, Regulatory Assurance Manager, at 315-349-6766.
I declare under penalty of perjury that the foregoing is true and correct. Executed on 19th day of December, 2014.
Sincerely, Brian R. Sullivan Site Vice President BRS/CMA/mh
Attachment:
Flooding Walkdown Report Open Items cc: NRC Regional Administrator NRC Resident Inspector Mr. Douglas Pickett, Senior Project Manager Ms. Bridget Frymire, NYSPSC Mr. John B. Rhodes, President and CEO, NYSERDA
JAFP-14-0145 Attachment Flooding Walkdown Report Open Items (1 Page)
Attachment JAFP-14-0145 Flooding Walkdown Report Open Items Description of Feature Deficiencies Deficiency Actions Taken or Planned Inaccessible Description Identified (yes/no)
(yes/no)
Description Electrical Manhole #2 No None. EC 51443 documents changes in EN-DC-170, No (MH-2) Att. 9.3 Flooding Walkdown Record form for Electrical Manhole #2. The purpose of the revision is to make administrative changes to be consistent with Reference 3.
Rx Bldg. Perimeter Drain No None. Pumps monitoring is performed under SP-01.11; Yes, This walkdown item has been Sump Pump A (75P-4A) the 12-dia. perimeter drains were inspected in reclassified as inaccessible versus a 2010. Video was reviewed for drain pipe previous classification of restricted degradation and determined to be acceptable access. The pump is located in 3 x 4 (JAF-RPT-12-00016, Section 7.1.3). sump pit which is only accessible by a 30 dia. x 36 vert. conc. shaft which extends EC 51443 documents that the pump has been downward from the bottom of a surface reclassified as inaccessible versus a restricted manhole; the pump is removed from the access feature. It also provides basis for sump pit and brought to the surface for reasonable assurance that pump 75P-4A will maintenance activities.
perform its external flood protection / mitigation function.
Rx Bldg. Perimeter Drain No None. Pumps monitoring is performed under SP-01.11; Yes, This walkdown item has been Sump Pump B (75P-4B) the 12-dia. perimeter drains were videoed in reclassified as inaccessible versus a 2010. Video was reviewed for drain pipe previous classification of restricted degradation and determined to be acceptable access. The pump is located in 3 x 4 (JAF-RPT-12-00016, Section 7.1.3). sump pit which is only accessible by a 30 dia. x 36 vert. conc. shaft which extends EC 51443 documents that the pump has been downward from the bottom of a surface reclassified as inaccessible versus a restricted manhole; the pump is removed from the access feature. It also provides basis for sump pit and brought to the surface for reasonable assurance that pump 75P-4B will maintenance activities.
perform its external flood protection / mitigation function.
Page 1 of 1
Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.
James A. FitzPatrick NPP P.O. Box 110 Lycoming, NY 13093 Tel 315-342-3840 Brian R. Sullivan Site Vice President - JAF JAFP-14-0145 December 19, 2014 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Subject:
Supplemental Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Flooding Aspects of Recommendations 2.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 License No. DPR-059
Reference:
- 1. NRC letter, Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Recommendations 2.1, 2.3, and 9.3, of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, ML12053A340, dated March 12, 2012
- 2. Entergy letter, Flooding Walkdown Report - Entergys Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Flooding Aspects of Recommendation 2.3 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident, JAFP-12-0135, dated November 27, 2012
- 3. Entergy Letter, Update to Response to NRC 10 CFR 50.54(f) Request for Information Regarding Near-Term Task Force Recommendation 2.3, Flooding - Review of Available Physical Margin (APM) Assessments, dated January 30, 2014, JAFP-14-0010
- 4. NEI letter, Generic Template for Closure of Flooding Design Basis Walkdown Restricted Access Items, APC 13-13, dated May 13, 2013
- 5. Entergy letter, Extension to Commitment in Flooding Walkdown Report for Restricted Access Equipment, JAFP-14-0121, dated October 30, 2014
Dear Sir or Madam:
On March 12, 2012, the Nuclear Regulatory Commission (NRC) issued Reference 1 to all power reactor licensees and holders of construction permits in active or deferred status. Enclosure 4 of Reference 1 requested that each licensee perform flood protection walkdowns and report the results. James A. FitzPatrick Nuclear Power Plant (JAF) submitted a Flooding Walkdown Report by Reference 2.
JAFP-14-0145 Page 2 of 2 Reference 2 identified items where restricted access prevented walkdown of certain flood protection features. Walkdowns of the restricted access items have been completed with the exception of the two perimeter drain pumps which have been reclassified as inaccessible features per the guidance provided in NEI 12-07 (Rev. 0-A) "Guidelines for Performing Verification Walkdowns of Plant Flood Protection Features" section 3.6.
The results are provided in the attachment to this letter. This submittal closes all the open items identified in Reference 2.
The attachment to this letter provides a list of the restricted access items inspected as well as those items reclassified as inaccessible, their respective disposition, and any action planned or taken. As a result of the inspections:
- There are no additional deficiencies found in the supplemental walkdown.
- No temporary measures were required as a result of the completed inspections.
- The restricted access item inspected was within the plant maintenance and monitoring programs.
- Available physical margin (APMs) were evaluated and documented in the walkdown record forms for each applicable item inspected in accordance with NEI 12-07.
- Two of the restricted access items were reclassified as inaccessible.
This letter contains no new regulatory commitments. If you have any questions regarding this report, please contact Chris M. Adner, Regulatory Assurance Manager, at 315-349-6766.
I declare under penalty of perjury that the foregoing is true and correct. Executed on 19th day of December, 2014.
Sincerely, Brian R. Sullivan Site Vice President BRS/CMA/mh
Attachment:
Flooding Walkdown Report Open Items cc: NRC Regional Administrator NRC Resident Inspector Mr. Douglas Pickett, Senior Project Manager Ms. Bridget Frymire, NYSPSC Mr. John B. Rhodes, President and CEO, NYSERDA
JAFP-14-0145 Attachment Flooding Walkdown Report Open Items (1 Page)
Attachment JAFP-14-0145 Flooding Walkdown Report Open Items Description of Feature Deficiencies Deficiency Actions Taken or Planned Inaccessible Description Identified (yes/no)
(yes/no)
Description Electrical Manhole #2 No None. EC 51443 documents changes in EN-DC-170, No (MH-2) Att. 9.3 Flooding Walkdown Record form for Electrical Manhole #2. The purpose of the revision is to make administrative changes to be consistent with Reference 3.
Rx Bldg. Perimeter Drain No None. Pumps monitoring is performed under SP-01.11; Yes, This walkdown item has been Sump Pump A (75P-4A) the 12-dia. perimeter drains were inspected in reclassified as inaccessible versus a 2010. Video was reviewed for drain pipe previous classification of restricted degradation and determined to be acceptable access. The pump is located in 3 x 4 (JAF-RPT-12-00016, Section 7.1.3). sump pit which is only accessible by a 30 dia. x 36 vert. conc. shaft which extends EC 51443 documents that the pump has been downward from the bottom of a surface reclassified as inaccessible versus a restricted manhole; the pump is removed from the access feature. It also provides basis for sump pit and brought to the surface for reasonable assurance that pump 75P-4A will maintenance activities.
perform its external flood protection / mitigation function.
Rx Bldg. Perimeter Drain No None. Pumps monitoring is performed under SP-01.11; Yes, This walkdown item has been Sump Pump B (75P-4B) the 12-dia. perimeter drains were videoed in reclassified as inaccessible versus a 2010. Video was reviewed for drain pipe previous classification of restricted degradation and determined to be acceptable access. The pump is located in 3 x 4 (JAF-RPT-12-00016, Section 7.1.3). sump pit which is only accessible by a 30 dia. x 36 vert. conc. shaft which extends EC 51443 documents that the pump has been downward from the bottom of a surface reclassified as inaccessible versus a restricted manhole; the pump is removed from the access feature. It also provides basis for sump pit and brought to the surface for reasonable assurance that pump 75P-4B will maintenance activities.
perform its external flood protection / mitigation function.
Page 1 of 1