James A. FitzPatrick NPP P.O. Box 110 Lycoming, NY 13093 Mark R. Hawes Regulatory Assurance JAFP-23-0059 October 24, 2023 United States Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001 James A. FitzPatrick Nuclear Power Plant Renewed Facility Operating License No. DPR-59 NRC Docket No. 50-333

Subject:

Registration of Spent Fuel Cask Use

Dear Sir or Madam:

Constellation Energy Generation, LLC (CEG), operates the James A. FitzPatrick Nuclear Power Plant (JAF) Independent Spent Fuel Storage Installation (ISFSI) in accordance with the general license provisions of 10 CFR 72.210. The conditions of 10 CFR 72.212(b)(2) include the registration of a spent fuel cask within 30 days of using a cask for storage of spent nuclear fuel.

Accordingly, JAF provides the following registration information associated with four (4)

HI-STORM 100 spent fuel cask systems that were recently placed into storage in the JAF ISFSI.

Cask Certificate of Compliance: 72-1014 Amendment 8, Rev 1 Cask Model: Holtec HI-STORM 100S Version B Overpack Serial Number: 1685 MPC Model: 68M MPC Serial Number: 805 Number of Fuel Bundles: 68 Placed in Service: 09/28/2023 Cask Certificate of Compliance: 72-1014 Amendment 8, Rev 1 Cask Model: Holtec HI-STORM 100S Version B Overpack Serial Number: 1686 MPC Model: 68M MPC Serial Number: 806 Number of Fuel Bundles: 68 Placed in Service: 10/11/2023

JAFP-23-0059 Page 2 of 2 Cask Certificate of Compliance: 72-1014 Amendment 8, Rev 1 Cask Model: Holtec HI-STORM 1OOS Version B Overpack Serial Number: 1687 MPC Model: 68M MPC Serial Number: 807 Number of Fuel Bundles: 68 Placed in Service: 10/13/2023 Cask Certificate of Compliance: 72-1014 Amendment 8, Rev 1 Cask Model: Holtec HI-STORM 1OOS Version B Overpack Serial Number: 1688 MPC Model: 68M MPC Serial Number: 808 Number of Fuel Bundles: 68 Placed in Service: 10/19/2023 Total Cask Systems stored in the JAF ISFSI: Thirty-six (36) HI-STORM 100 Cask Systems.

This letter contains no new regulatory commitments. Should you have any questions or require further information, please contact me, at (315) 349-6659.

Very truly yours,

)0_/t~

Mark R. Hawes Regulatory Assurance MAH cc: Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 NRC, Regional Administrator NRC, Resident Inspector NRC, NRA Project Manager NYSPSC NYSERDA