Failure to Implement Requirements for Biennial Medical Examinations and Notification to the NRC of Changes in Licensed Operator Medical ConditionsML031060622 |
Person / Time |
---|
Site: |
Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant ![Entergy icon.png](/w/images/7/79/Entergy_icon.png) |
---|
Issue date: |
02/24/1994 |
---|
From: |
Grimes B Office of Nuclear Reactor Regulation |
---|
To: |
|
---|
References |
---|
IN-94-014, NUDOCS 9402170298 |
Download: ML031060622 (11) |
|
Similar Documents at Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Category:NRC Information Notice
MONTHYEARInformation Notice 2020-02, Flex Diesel Generator Operational Challenges2020-09-15015 September 2020 Flex Diesel Generator Operational Challenges ML20225A0322020-09-0303 September 2020 NRC Choice Letter to NAC International with Attached Safety Inspection Report, IR 0721015/2020201, February 24-27, 2020 and July 22, 2020, Inspection of NAC International in Norcross, Georgia Information Notice 2012-09, PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs.2019-11-30030 November 2019 PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs. Information Notice 2011-20, NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011)2019-07-24024 July 2019 NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011) ML19196A2452019-07-15015 July 2019 Public Notice - Sequoyah Nuclear Plant, Unit 2 - Exigent Amendment to Facility Operating License Information Notice 2019-01, Inadequate Evaluation of Temporary Alterations2019-03-12012 March 2019 Inadequate Evaluation of Temporary Alterations ML16028A3082016-04-27027 April 2016 NRC Information Notice; IN 2016-05: Operating Experience Regarding Complications From a Loss of Instrumentation Air Information Notice 2015-05, Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps Information Notice 2015-05, Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps Information Notice 2013-20, OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-20, Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-11, OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2013-11, Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Contain2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Con2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notic2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2012-13, Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool Information Notice 2012-13, Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool Information Notice 2012-11, Age Related Capacitor Degradation2012-07-23023 July 2012 Age Related Capacitor Degradation ML12031A0132012-02-0606 February 2012 U.S. Nuclear Regulatory Commission Investigation Report No. 2-2010-058, Cpn International, Inc Information Notice 2011-19, Licensee Event Reports Containing Information Pertaining to Defects to Basic Components2011-09-26026 September 2011 Licensee Event Reports Containing Information Pertaining to Defects to Basic Components Information Notice 2011-15, Steel Containment Degradation and Associated License Renewal Aging Management Issues2011-08-0101 August 2011 Steel Containment Degradation and Associated License Renewal Aging Management Issues Information Notice 2011-17, Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping2011-07-26026 July 2011 Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping Information Notice 2011-13, Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-13, Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13)2011-06-29029 June 2011 Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13) Information Notice 2011-13, OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-04, IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-262010-12-21021 December 2010 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 ML13066A1872009-12-16016 December 2009 Draft NRC Information Notice 2009-xx - Underestimate of Dam Failure Frequency Used in Probabilistic Risk Assessments ML1007804482009-11-23023 November 2009 Email from Peter Bamford, NRR to Pamela Cowan, Exelon on TMI Contamination Control Event Information Notice 2009-11, NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-112009-07-0707 July 2009 NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-11 Information Notice 2009-10, Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10)2009-07-0707 July 2009 Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10) Information Notice 2009-09, Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify2009-06-19019 June 2009 Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify Information Notice 2008-12, Reactor Trip Due to Off-Site Power Fluctuation2008-07-0707 July 2008 Reactor Trip Due to Off-Site Power Fluctuation Information Notice 2008-11, Service Water System Degradation at Brunswicksteam Electric Plant Unit 12008-06-18018 June 2008 Service Water System Degradation at Brunswicksteam Electric Plant Unit 1 Information Notice 2008-04, Counterfeit Parts Supplied to Nuclear Power Plants2008-04-0707 April 2008 Counterfeit Parts Supplied to Nuclear Power Plants Information Notice 1991-09, Counterfeiting of Crane Valves2007-09-25025 September 2007 Counterfeiting of Crane Valves Information Notice 2007-28, Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls2007-09-19019 September 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls Information Notice 2007-29, Temporary Scaffolding Affects Operability of Safety-Related Equipment2007-09-17017 September 2007 Temporary Scaffolding Affects Operability of Safety-Related Equipment Information Notice 2007-14, Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station2007-03-30030 March 2007 Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station Information Notice 2007-06, Potential Common Cause Vulnerabilities in Essential Service Water Systems2007-02-0909 February 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Information Notice 2007-05, Vertical Deep Draft Pump Shaft and Coupling Failures2007-02-0909 February 2007 Vertical Deep Draft Pump Shaft and Coupling Failures Information Notice 2006-31, Inadequate Fault Interrupting Rating of Breakers2006-12-26026 December 2006 Inadequate Fault Interrupting Rating of Breakers Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear Information Notice 2006-13, E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination2006-07-13013 July 2006 E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination 2020-09-03 The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>.
[Table view]The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>. |
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF NUCLEAR REACTOR REGULATION
WASHINGTON, D.C. 20555 February 24, 1994 NRC INFORMATION NOTICE 94-14: FAILURE TO IMPLEMENT REQUIREMENTS FOR BIENNIAL
MEDICAL EXAMINATIONS AND NOTIFICATION TO THE
NRC OF CHANGES IN LICENSED OPERATOR MEDICAL
CONDITIONS
Addressees
All holders of operating licenses or construction permits for nuclear power
and non-power reactors and all licensed reactor operators and senior reactor
operators.
PurDose
The U.S. Nuclear Regulatory Commission (NRC) is issuing this information
notice to remind addressees of the requirements for licensed reactor operators
and senior reactor operators (licensees) to be examined by a physician every
2 years and for facility licensees to notify the NRC of changes in a licensed
operator's physical or mental condition, as determined by a physician, that
cause the operator to fail to meet the medical requirements of Title 10 of the
Code of Federal Regulations Part 55, "Operators' Licenses" (10 CFR Part 55).
It is expected that recipients will review the information for applicability
and consider actions, as appropriate, to avoid similar problems. However, suggestions contained in this information notice are not NRC requirements;
therefore, no specific action or written response is required.
Background
10 CFR 55.21, "Medical examination," requires NRC-licensed operators to be
examined by a physician every 2 years. The purpose of this examination is to
determine if the individual meets the requirements of 10 CFR 55.33(a)(1).
Further, 10 CFR 55.23 specifies that an authorized representative of the
facility licensee shall complete and sign NRC Form 396, "Certification of
Medical Examination by Facility Licensee," to certify the medical fitness of
the individual. By signing NRC Form 396, the facility licensee certifies that
(1) the guidance in American Nuclear Society Standard, ANSI/ANS 3.4-1983,
"Medical Certification and Monitoring of Personnel Requiring Operator Licenses
for Nuclear Power Plants," was followed in determining the medical fitness of
an operator for power reactors, or (2) the guidance in ANSI/ANS 15.4-1988,
"Selection and Training of Personnel for Research Reactors," was followed in
determining the medical fitness of an operator for non-power reactors. If the
guidance in these documents was not used, a facility licensee may certify that
an alternative method, acceptable to the NRC, was used.
As indicated in 10 CFR 50.54(i), the facility licensee is responsible for
ensuring that (1) facility controls are manipulated only by operators licensed
9402170298 p _Tg Vo+fc1eI 91-f' f?( f0 W
IDbV~~ -Ie-//c OAi
--iN 94-14 February 24, 1994 under 10 CFR Part 55 and (2) only operators so licensed are permitted to
direct manipulation of the facility controls. This responsibility includes
ensuring that any conditions or limitations to an operator's license are
followed. Controls in this sense are defined in 10 CFR 55.4 as apparatus and
mechanisms the manipulation of which directly affects the reactivity or power
level of the reactor.
Description of Circumstances
During recent inspections of the implementation of the above requirements, the NRC determined that some facility licensees did not ensure that the
restrictions or limitations to an operator's license were followed. Further, the NRC found examples where facility licensees failed to notify the NRC of
changes in a licensed operator's medical condition. An inspection of licensed
operator medical records at the Brunswick Steam Electric Plant found that a
physician had determined that (1) the eyesight of four licensed operators did
not meet the medical standards described in ANSI/ANS-3.4-1983 and (2) a
licensed operator's medical condition required that the operator not perform
licensee duties alone. These changes in the licensed operators' conditions
should have been reported to the NRC as required by 10 CFR 55.25. In 1993, NRC inspectors found 74 instances at Region III facilities where licensed
operators had not had a medical examination within the 2-year period
prescribed by 10 CFR 55.21. In one instance, the time since the last medical
examination exceeded 4 years.
Discussion
The responsibility for ensuring that only personnel licensed in accordance
with 10 CFR Part 55 are permitted to manipulate or direct the manipulation of
the controls of a licensed facility rests with the facility licensee. The NRC
considers proper certification to medical standards, as required by
10 CFR 55.23, to be the basis for finding that a licensed operator's medical
condition and general health will not adversely affect performance of assigned
operator duties or cause operational errors that endanger public health and
safety. 10 CFR Part 55 Subpart C, "Medical Requirements," states that
licensed operators shall have a medical examination by a physician every
2 years. If, during the term of the license, the operator develops a
permanent physical or mental condition that causes the operator to fail to
meet the requirements of 10 CFR 55.21, the facility licensee shall, in
accordance with 10 CFR 55.25, notify the Commission within 30 days of learning
of the diagnosis.
Deficiencies were found during NRC inspections in facility medical examination
programs for applicants for licenses and for licensed operators. The results
of these inspections indicate that some facility programs may not be receiving
sufficient management oversight to ensure that the medical qualifications of
licensed operators and applicants for licenses are maintained at the required
level. This information notice reminds facility licensees that, prior to
submitting NRC Form 396, the facility licensee needs to ensure that medical
examinations performed by physicians for certifying the fitness of operators
Att'avthment
IN 94-14 February 24, 1994 LIST OF RECENTLY ISSUED
NRC INFORMATION NOTICES
Information Date of
Notice No. Subject Issuance Issued to
92-36, Intersystem LOCA 02/22/94 All holders of OLs or CPs
Supp. I Outside Containment for nuclear power reactors.
94-I3 Unanticipated and Un- 02/22/94 All holders of OLs or CPs
intended Movement of for nuclear power reactors.
Fuel Assemblies and
Other Components due to
Improper Operation of
Refueling Equipment
94-12 Insights Gained from 02/09/94 All holders of OLs or CPs
Resolving Generic for nuclear power reactors.
Issue 57: Effects of
Fire Protection System
Actuation on Safety- Related Equipment
94-11 Turbine Overspeed and 02/08/94 All holders of OLs or CPs
Reactor Cooldown during for nuclear power reactors.
Shutdown Evolution
94-10 Failure of Motor-Operated 02/04/94 All holders of OLs or CPs
Valve Electric Power for nuclear power reactors.
Train due to Sheared or
Dislodged Motor Pinion
Gear Key
94-09 Release of Patients with 02/03/94 All U.S. Nuclear Regulatory
Residual Radioactivity Commission medical
from Medical Treatment and licensees.
Control of Areas due to
Presence of Patients Con- taining Radioactivity
Following Implementation
of Revised 10 CFR Part 20
94-08 Potential for Surveil- 01/01/94 All holders of OLs or CPs
lance Testing to Fail for nuclear power reactors.
to Detect an Inoperable
Main Steam Isolation Valve
OL = Operating License
CP - Construction Permit
K-' \%U-4N 94-14 February 24, 1994 are complete and accurate and that any restriction or limitation to an
operator's license resulting from the examination is complied with.
10 CFR 55.25 requires that the NRC be notified when a licensed operator's
medical condition no longer meets the original licensing standard and that an
appropriate certification form be submitted if the facility licensee is
requesting a conditional license to accommodate the change in the operator's
physical or mental condition. NRC Information Notice 91-08, "Medical
Examination for Licensed Operators," February 5, 1991, provides additional
information on this subject.
This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the contacts listed below or the appropriate Office of Nuclear Reactor
Regulation (NRR) project manager.
Odginal signed by
Brian ILGrmes
Brian K. Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Reactor Regulation
Technical contacts: R. J. Conte, RI J. L. Pellet, RIV
(610) 337-5210 (817) 860-8159 T. A. Peebles, R11 P. J. Morrill, RV
(404) 331-5541 (510) 975-0293 M. A. Ring, RIII D. J. Lange, NRR
(708) 829-9703 (301) 504-3171 Attachment:
List of Recently Issued NRC Information Notices
SEE PREVIOUS CONCURRENCE*
Region I Region II Region III Region IV Region V
RConte* TPeebles* MRing* JPellet* PMorrill*
01/27/94 01/28/94 01/27/94 01/25/94 02/02/94 HOLB:DRCH:NRR C/HOLB:DRCH:NRR C/ONDD:NRR D/DRCH:NRR
DLange* RGallo* SWeiss* BBoger*
01/26/94 01/24/94 01/27/94 01/26!/ 9 TechEd OGCB:DORS:NRR AC/OGCB:DORS:NRR
RSanders* JBirmingham* AJKugler*
01/13/94 02/03/94 02/07/94 9-O$7IC/94 OFFICIAL DOCUMENT NAME: 94-14. IN
K...AIN 94-14 February 24, 1994 are complete and accurate and that any restriction or limitation to an
operator's license resulting from the examination is complied with.
10 CFR 55.25 requires that the NRC be notified when a licensed operator's
medical condition no longer meets the original licensing standard and that an
appropriate certification form be submitted if the facility licensee is
requesting a conditional license to accommodate the change in the operator's
physical or mental condition. NRC Information Notice 91-08, "Medical
Examination for Licensed Operators," February 5, 1991, provides additional
information on this subject.
This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the contacts listed below or the appropriate Office of Nuclear Reactor
Regulation (NRR) project manager.
Brian K. Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Reactor Regulation
Technical contacts: R. J. Conte, RI J. L. Pellet, RIV
(610) 337-5210 (817) 860-8159 T. A. Peebles, R11 P. J. Morrill, RV
(404) 331-5541 (510) 975-0293 M. A. Ring, RIII D. J. Lange, NRR
(708) 829-9703 (301) 504-3171 Attachment:
List of Recently Issued NRC Information Notices
K.- /
IN 94-XX
February X, 1994 It is important that the NRC be notified when a licensed operator's medical
condition no longer meets the original licensing standard and that the
facility licensee is requesting a conditional license to accommodate the
change in the operator's physical or mental condition. NRC Information Notice
91-08, 'Medical Examination for Licensed Operators," February 5, 1991, provides additional information on this subject.
This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the technical contacts listed below or the appropriate Office of
Nuclear Reactor Regulation (NRR) project manager.
Brian K. Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Reactor Regulation
Technical contacts: R. J. Conte, RI J. L. Pellet, RIV
(215) 337-5210 (817) 860-8159 T. A. Peebles, RII P. J. Morrill, RV
(404) 331-5541 (510) 975-0293 M. A. Ring, RIII D. J. Lange, NRR
(708) 829-9703 (301) 504-3171 Attachment:
List of Recently Issued NRC Information Notices
SEE PREVIOUS CONCURRENCE*
Region I Region II Region III Region IV Region V
RConte TPeebles MRing JPellet* PMorrill
01/ /94 01/ /94 01/ /94 01/24/94 01/ /94 HOLB:DRCH:NRR C/HOLB:DRCH:NRR D/DRCH:NRR C/ONDD:NRR
DLange* RGallo* BBoger* SWei ss
01/26/94 01/24/94 01/26/94 01/ /94 TechEd OGCB:DORS:NRR C/OGCB:DORS:NRR D/DORS:NRR
RSanders JBirmingham GHMarcus BKGrimes
01/13/94 01/ /94 01/ /94 01/ /94 OFFICIAL DOCUMENT NAME: MDCLEXAM.JLB
IN 94-XX
January, XX, 1994 This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the technical contacts listed below or the appropriate Office of
Nuclear Reactor Regulation (NRR) project manager.
Brian K. Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Reactor Regulation
Technical contacts: R. J. Conte, RI J. L. Pellet, RIV
(215) 337-5210 (817) 860-8159 T. A. Peebles, RII P. J. Morrill, RV
(404) 331-5541 (510) 975-0293 M. A. Ring, RIII D. J. Lange, NRR
(708) 829-9703 (301) 504-3171 Attachment:
List of Recently Issued NRC Information Notices
SEE PREVIOUS CONCURRENCE*
Region I Region II Region III Region LYAc-Region V
RConte TPeebles MRing JPelletC"'f6PMorrill
01/ /94 01/ /94 01/ /94 01/xqJ/94 01/ /94 HOLB:DRCIJ:VR C/HOLB:D RCH:NRR C/ONDD:NRR
DLangej0 ,j .. .RGallo* O/ /94 SWeiss
01 A /94L d1 01/24/94 01/ /94 TechEd P OGCB:DORS:NRR C/OGCB:DORS:NRR D/DORS:NRR
RSandefst* JBirmingham GHMarcus BKGrimes
01/13/94 01/ /94 01/ /94 01/ /94 OFFICIAL DOCUMENT NAME: MDCLEXAM.JLB
j.-1 IN 94-XX
January, XX, 1994 This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the technical contacts listed below or the appropriate Office of
Nuclear Reactor Regulation (NRR) project manager.
Brian K. Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Reactor Regulation
Technical contacts: L. H. Bettenhausen, RI J. L. Pellet, RIV
215-337-5291 817-860-8159 L. L. Lawyer, RII P. J. Morrill, RV
404-331-4700 510-975-0293 M. A. Ring, RII D. J. Lange, NRR
708-790-5602 301-504-3171 Attachment:
List of Recently Issued NRC Information Notices
SEE PREVIOUS CONCURRENCE*
Region I Region II Region III Region IV Region V
LBettenhausen LLawyer MRing JPellet PMorrill
O/ /94 01/ /94 01/ /94 01/ /94 01/ /94
- NRR C/HOLB: RES5ERR D/DRCH:NRR C/ONDD:NRR OGC
M0 RGallo MP BBoger SWeiss SLewis
01 / 01/y294 01/ /94 01/ /94 01/ /94 TechEd 8 8 OGCB:DORS:NRR C/OGCB:DORS:NRR D/DORS:NRR
RSandergl JBirmingham GHMarcus BKGrimes
01/13/94 01/ /94 01/ /94 01/ /94 OFFICIAL DOCUMENT NAME: MDCLEXAM.JLB
IN 94-XX
January, XX, 1994 This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the technical contacts listed below or the appropriate Office of
Nuclear Reactor Regulation (NRR) project manager.
Brian K. Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Reactor Regulation
Technical contacts: R. J. Conte, RI J. L. Pellet, RIV
(215) 337-5210 (817) 860-8159 T. A. Peebles, RII P. J. Morrill, RV
(404) 331-5541 (510) 975-0293 M. A. Ring, RIII D. J. Lange, NRR
(708) 829-9703 (301) 504-3171 Attachment:
List of Recently Issued NRC Information Noti
SEE PREVIOV ON(
Region IWjL# Region I Region V a
RConte TPeebl es .PMorrilI n
01/247/9 01/1949 JX/ /94 -e-- A
9 /21t
C/HOLB:DRCH:NRR D/DRCH:NRR
RGallo* BBoger
01/24/94 01/ /94 o01z 7/94 TechEd OGCB::DORS:NRI, C/OGCB:DORS:NRR D/DORS:NRR
RSanders JBJrmni ng ham//%X GHMarcus BKGrimes
01/13/94 Xf11/1 /94 01/ /94 01/ /94
2.
OFFICIAL DOCUMENT NAME: MDCLEXAM.JLB
IN 94-XX
February X, 1994 operators are complete and accurate and that any restriction or limitation to
an operator's license resulting from the examination is complied with.
It is important that the NRC be notified when a licensed operator's medical
condition no longer meets the original licensing standard and that the
facility licensee is requesting a conditional license to accommodate the
change in the operator's physical or mental condition. NRC Information Notice
91-08, 'Medical Examination for Licensed Operators," February 5, 1991, provides additional information on this subject.
This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the persons listed below or the appropriate Office of Nuclear Reactor
Regulation (NRR) project manager.
Brian K. Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Reactor Regulation
Technical contacts: R. J. Conte, RI J. L. Pellet, RIV
(610) 337-5210 (817) 860-8159 T. A. Peebles, RII P. J. Morrill, RV
(404) 331-5541 (510) 975-0293 M. A. Ring, RIII D. J. Lange, NRR
(708) 829-9703 (301) 504-3171 Attachment:
List of Recently Issued NRC Information Notices
SEE PREVIOUS CONCURRENCE*
Region I Region II Region III Region IV Region V
RConte* TPeebles* MRing* JPellet* PMorrill*
01/27/94 01/28/94 01/27/94 01/25/94 02/02/94 HOLB:DRCH:NRR C/HOLB:DRCH:NRR C/ONDD:NRR D/DRCH:NRR
DLange* RGallo* SWeiss* BBoger*
01/26/94 01/24/94 01/27/94 01/26/94 TechEd OGCB:DORS:NRR AC/OGCB:DORS:NRR D/DORS:NRR
RSanders* JBirmingham* AJKugler J k- BKGrimes
01/13/94 02/03/94 02/7/94 02/ /94 OFFICIAL DOCUMENT NAME: MDCLEXAM.JLB
IN 94-14 February 24, 1994 are complete and accurate and that any restriction or limitation to an
operator's license resulting from the examination is complied with.
10 CFR 55.25 requires that the NRC be notified when a licensed operator's
medical condition no longer meets the original licensing standard and that an
appropriate certification form be submitted if the facility licensee is
requesting a conditional license to accommodate the change in the operator's
physical or mental condition. NRC Information Notice 91-08, 'Medical
Examination for Licensed Operators," February 5, 1991, provides additional
information on this subject.
This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the contacts listed below or the appropriate Office of Nuclear Reactor
Regulation (NRR) project manager.
Odginal -tgned by
Brian K. Grims
Brian K. Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Reactor Regulation
Technical contacts: R. J. Conte, RI J. L. Pellet, RIV
(610) 337-5210 (817) 860-8159 T. A. Peebles, RII P. J. Morrill, RV
(404) 331-5541 (510) 975-0293 M. A. Ring, RIII D. J. Lange, NRR
(708) 829-9703 (301) 504-3171 Attachment:
List of Recently Issued NRC Information Notices
SEE PREVIOUS CONCURRENCE*
Region I Region II Region III Region IV Region V
RConte* TPeebles* MRing* JPellet* PMorrill*
01/27/94 01/28/94 01/27/94 01/25/94 02/02/94 HOLB:DRCH:NRR C/HOLB:DRCH:NRR C/ONDD:NRR D/DRCH:NRR
DLange* RGallo* SWeiss* BBoger*
01/26/94 01/24/94 01/27/94 01/26 9 TechEd OGCB:DORS:NRR AC/OGCB:DORS:NRR
RSanders* JBirmingham* AJKugler*
01/13/94 02/03/94 02/07/94 21t/94 OFFICIAL DOCUMENT NAME: 94-14.IN
|
---|
|
list | - Information Notice 1994-01, Turbine Blade Failures Caused by Torsional Excitation from Electrical System Disturbance (7 January 1994)
- Information Notice 1994-02, Inoperability of General Electric Magne-Blast Breaker Because of Misalignment of Close-Latch Spring (7 January 1994)
- Information Notice 1994-03, Deficiencies Identified During Service Water System Operational Performance Inspections (11 January 1994, Topic: Biofouling)
- Information Notice 1994-04, Digital Integrated Circuit Sockets with Intermittent Contact (14 January 1994)
- Information Notice 1994-05, Potential Failure of Steam Generator Tubes with Kinetically Welded Sleeves (19 January 1994)
- Information Notice 1994-06, Potential Failure of Long-Term Emergency Nitrogen Supply for the Automatic Depressurization System Valves (28 January 1994)
- Information Notice 1994-07, Solubility Criteria for Liquid Effluent Releases to Sanitary Sewerage Under the Revised 10 CFR Part 20 (28 January 1994)
- Information Notice 1994-08, Potential for Surveillance Testing to Fail to Detect an Inoperable Main Steam Isolation Valve (1 February 1994)
- Information Notice 1994-09, Release of Patients with Residual Radioactivity from Medical Treatment & Control of Areas Due to Presence of Patients Containing Radioactivity Following Implementation of Revised 10 CFR Part 20 (3 February 1994, Topic: Brachytherapy)
- Information Notice 1994-10, Failure of Motor-Operated Valve Electric Power Train Due to Sheared or Dislodged Motor Pinion Gear Key (4 February 1994)
- Information Notice 1994-11, Turbine Overspeed and Reactor Cooldown During Shutdown Evolution (8 February 1994)
- Information Notice 1994-12, Insights Gained from Resolving Generic Issue 57: Effects of Fire Protection System Actuation on Safety-Related Equipment (9 February 1994)
- Information Notice 1994-13, Unanticipated and Unintended Movement of Fuel Assemblies and Other Components Due to Improper Operation of Refueling Equipment (28 June 1994)
- Information Notice 1994-14, Failure to Implement Requirements for Biennial Medical Examinations and Notification to the NRC of Changes in Licensed Operator Medical Conditions (24 February 1994)
- Information Notice 1994-15, Radiation Exposures During an Event Involving a Fixed Nuclear Gauge (2 March 1994)
- Information Notice 1994-16, Recent Incidents Resulting in Offsite Contamination (3 March 1994)
- Information Notice 1994-17, Strontium-90 Eye Applicators: Submission of Quality Management Plan (QMP), Calibration, and Use (11 March 1994, Topic: Brachytherapy)
- Information Notice 1994-17, Strontium-90 Eye Applicators: Submission of Quality Management Plan (Qmp), Calibration, and Use (11 March 1994, Topic: Brachytherapy)
- Information Notice 1994-18, Accuracy of Motor-Operated Valve Diagnostic Equipment (Responses to Supplement 5 to Generic Letter 89-10) (16 March 1994)
- Information Notice 1994-19, Emergency Diesel Gemerator Vulnerability to Failure from Cold Fuel Oil (16 March 1994)
- Information Notice 1994-20, Common-Cause Failures Due to Inadequate Design Control and Dedication (17 March 1994)
- Information Notice 1994-21, Regulatory Requirements When No Operations Are Being Performed (18 March 1994)
- Information Notice 1994-22, Fire Endurance & Ampacity Derating Test Results for 3-Hour Fire-Rated Thermo-Lag 330-1 Fire Barriers (16 March 1994, Topic: Fire Barrier)
- Information Notice 1994-23, Guidance to Hazardous, Radioactive and Mixed Waste Generators on the Elements of a Waste Minimization Program (25 March 1994, Topic: Fire Barrier)
- Information Notice 1994-24, Inadequate Maintenance of Uninterruptible Power Supplies & Inverters (24 March 1994, Topic: Safe Shutdown, Fire Barrier)
- Information Notice 1994-25, Failure of Containment Spray Header Valve to Open Due to Excessive Pressure from Inertial Effects of Water (15 March 1994, Topic: Fire Barrier)
- Information Notice 1994-26, Personnel Hazards and Other Problems from Smoldering Fire-Retardant Material in the Drywell of a Boiling-Water Reactor (28 March 1994, Topic: Fire Barrier)
- Information Notice 1994-27, Facility Operating Concerns Resulting from Local Area Flooding (31 March 1994, Topic: Fire Barrier)
- Information Notice 1994-28, Potential Problems with Fire-Barrier Penetration Seals (5 April 1994, Topic: Fire Barrier)
- Information Notice 1994-29, Charging Pump Trip During a Loss-of-Coolant Event Caused by Low Suction Pressure (11 April 1994, Topic: Boric Acid)
- Information Notice 1994-30, Leaking Shutdown Cooling Isolation Valves at Cooper Nuclear Station (19 August 1994, Topic: Fire Barrier)
- Information Notice 1994-31, Potential Failure of Wilco, Lexan-Type HN-4-L Fire Hose Nozzles (14 April 1994, Topic: Hydrostatic)
- Information Notice 1994-32, Revised Seismic Estimates (29 April 1994, Topic: Earthquake)
- Information Notice 1994-33, Capacitor Failures in Westinghouse Eagle 21 Plant Protection Systems (9 May 1994)
- Information Notice 1994-34, Thermo-LAG 330-660 Flexi-Blanket Ampacity Derating Concerns (13 May 1994, Topic: Fire Barrier)
- Information Notice 1994-35, Niosh Respirator User Notices, Inadvertent Separation of the Mask-Mounted Regulator(Mmr) from the Facepiece on the Mine Safety Appliances (16 May 1994)
- Information Notice 1994-35, Niosh Respirator User Notices, Inadvertent Separation of the Mask-Mounted Regulator(MMR) from the Facepiece on the Mine Safety Appliances (16 May 1994)
- Information Notice 1994-36, Undetected Accumulation of Gas in Reactor Coolant System (24 May 1994, Topic: Reactor Vessel Water Level)
- Information Notice 1994-37, Misadministration Caused by a Bent Interstitial Needle During Brachytherapy Procedure (27 May 1994, Topic: Brachytherapy)
- Information Notice 1994-38, Results of Special NRC Inspection at Dresden Nuclear Power Station, Unit 1 Following Rupture of Service Water Inside Containment (27 May 1994)
- Information Notice 1994-39, Identified Problems in Gamma Stereotactic Radiosurgery (31 May 1994)
- Information Notice 1994-40, Failure of a Rod Control Cluster Assembly to Fully Insert Following a Reactor Trip at Braidwood, Unit 2 (26 May 1994)
- Information Notice 1994-41, Problems with General Electric Type Cr124 Overload Relay Ambient Compensation (7 June 1994)
- Information Notice 1994-41, Problems with General Electric Type CR124 Overload Relay Ambient Compensation (7 June 1994)
- Information Notice 1994-42, Cracking in the Lower Region of the Core Shroud in Boiling-Water Reactors (7 June 1994)
- Information Notice 1994-43, Determination of Primary-to-Secondary Steam Generator Leak Rate (10 June 1994, Topic: Grab sample)
- Information Notice 1994-44, Main Steam Isolation Valve Failure to Close on Demand Because of Inadequate Maintenance and Testing (16 June 1994)
- Information Notice 1994-44, Main Steam Isolation Valve Failure to Close on Demand because of Inadequate Maintenance and Testing (16 June 1994)
- Information Notice 1994-45, Potential Common-Mode Failure Mechanism for Large Vertical Pumps (17 June 1994, Topic: Biofouling)
- Information Notice 1994-46, Nonconservative Reactor Coolant System Leakage Calculation (20 June 1994)
... further results |
---|