Degradation of Boraflex Neutron Absorber CouponsML031070107 |
Person / Time |
---|
Site: |
Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Issue date: |
09/10/1993 |
---|
From: |
Grimes B Office of Nuclear Reactor Regulation |
---|
To: |
|
---|
References |
---|
-nr IN-93-070, NUDOCS 9309070206 |
Download: ML031070107 (9) |
|
Similar Documents at Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Category:NRC Information Notice
MONTHYEARInformation Notice 2020-02, Flex Diesel Generator Operational Challenges2020-09-15015 September 2020 Flex Diesel Generator Operational Challenges ML20225A0322020-09-0303 September 2020 NRC Choice Letter to NAC International with Attached Safety Inspection Report, IR 0721015/2020201, February 24-27, 2020 and July 22, 2020, Inspection of NAC International in Norcross, Georgia Information Notice 2012-09, PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs.2019-11-30030 November 2019 PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs. Information Notice 2011-20, NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011)2019-07-24024 July 2019 NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011) ML19196A2452019-07-15015 July 2019 Public Notice - Sequoyah Nuclear Plant, Unit 2 - Exigent Amendment to Facility Operating License Information Notice 2019-01, Inadequate Evaluation of Temporary Alterations2019-03-12012 March 2019 Inadequate Evaluation of Temporary Alterations ML16028A3082016-04-27027 April 2016 NRC Information Notice; IN 2016-05: Operating Experience Regarding Complications From a Loss of Instrumentation Air Information Notice 2015-05, Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps Information Notice 2015-05, Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps Information Notice 2013-20, OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-20, Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-11, OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2013-11, Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Contain2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Con2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notic2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2012-13, Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool Information Notice 2012-13, Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool Information Notice 2012-11, Age Related Capacitor Degradation2012-07-23023 July 2012 Age Related Capacitor Degradation ML12031A0132012-02-0606 February 2012 U.S. Nuclear Regulatory Commission Investigation Report No. 2-2010-058, Cpn International, Inc Information Notice 2011-19, Licensee Event Reports Containing Information Pertaining to Defects to Basic Components2011-09-26026 September 2011 Licensee Event Reports Containing Information Pertaining to Defects to Basic Components Information Notice 2011-15, Steel Containment Degradation and Associated License Renewal Aging Management Issues2011-08-0101 August 2011 Steel Containment Degradation and Associated License Renewal Aging Management Issues Information Notice 2011-17, Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping2011-07-26026 July 2011 Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping Information Notice 2011-13, Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-13, Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13)2011-06-29029 June 2011 Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13) Information Notice 2011-13, OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-04, IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-262010-12-21021 December 2010 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 ML13066A1872009-12-16016 December 2009 Draft NRC Information Notice 2009-xx - Underestimate of Dam Failure Frequency Used in Probabilistic Risk Assessments ML1007804482009-11-23023 November 2009 Email from Peter Bamford, NRR to Pamela Cowan, Exelon on TMI Contamination Control Event Information Notice 2009-11, NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-112009-07-0707 July 2009 NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-11 Information Notice 2009-10, Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10)2009-07-0707 July 2009 Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10) Information Notice 2009-09, Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify2009-06-19019 June 2009 Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify Information Notice 2008-12, Reactor Trip Due to Off-Site Power Fluctuation2008-07-0707 July 2008 Reactor Trip Due to Off-Site Power Fluctuation Information Notice 2008-11, Service Water System Degradation at Brunswicksteam Electric Plant Unit 12008-06-18018 June 2008 Service Water System Degradation at Brunswicksteam Electric Plant Unit 1 Information Notice 2008-04, Counterfeit Parts Supplied to Nuclear Power Plants2008-04-0707 April 2008 Counterfeit Parts Supplied to Nuclear Power Plants Information Notice 1991-09, Counterfeiting of Crane Valves2007-09-25025 September 2007 Counterfeiting of Crane Valves Information Notice 2007-28, Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls2007-09-19019 September 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls Information Notice 2007-29, Temporary Scaffolding Affects Operability of Safety-Related Equipment2007-09-17017 September 2007 Temporary Scaffolding Affects Operability of Safety-Related Equipment Information Notice 2007-14, Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station2007-03-30030 March 2007 Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station Information Notice 2007-06, Potential Common Cause Vulnerabilities in Essential Service Water Systems2007-02-0909 February 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Information Notice 2007-05, Vertical Deep Draft Pump Shaft and Coupling Failures2007-02-0909 February 2007 Vertical Deep Draft Pump Shaft and Coupling Failures Information Notice 2006-31, Inadequate Fault Interrupting Rating of Breakers2006-12-26026 December 2006 Inadequate Fault Interrupting Rating of Breakers Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear Information Notice 2006-13, E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination2006-07-13013 July 2006 E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination 2020-09-03 The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>.
[Table view]The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>. |
I
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF NUCLEAR REACTOR REGULATION
WASHINGTON D.C. 20555 September 10, 1993 NRC INFORMATION NOTICE 93-70: DEGRADATION OF BORAFLEX NEUTRON ABSORBER
COUPONS
Addressees
permits for nuclear power
All holders of operating licenses or construction
reactors.
PurDose
is issuing this information
The U.S. Nuclear Regulatory Commission (NRC) significant problem pertaining to
notice to alert recipients to a potentially coupons. It is expected that
degradation of Boraflex neutron absorber applicability to their facilities
recipients will review the information foravoid similar problems. However, and consider actions, as appropriate, to notice are not NRC requirements;
suggestions contained in this information response is required.
therefore, no specific action or written
Background
installed in the spent fuelpool
Palisades has high-density fuel storage racksabsorbing material that was
that use Boraflex, a proprietary neutron Incorporated (BISCO). The storage
manufactured by Brand Industrial Services,Boraflex is attached to the walls of
racks are supplied by Westinghouse. The steel wrapper, which is spot
each canister and is held in place by a stainless
welded to the walls.
Boraflex coupons to indicate the
The licensee has a surveillance program using density storage racks in the
status of the Boraflex contained in the high of several of these coupons, spent fuel pool. Recently observed degradation gamma radiation in conjunction with
which may be due to exposure to high level about the integrity of the
interaction with pool water, raised questionsSignificant loss of Boraflex in the
Boraflex contained in the storage racks. of the subcriticality margin in
high-density fuel racks could result in loss '
the spent fuel pool.
was required to test and inspect
Through a commitment to the NRC, Palisades The tests include opening the
the Boraflex coupons after 5 years of use. determination, and a
coupons for visual observation, neutron attenuation
Boraflex hardness test.
DescriDtion of Circumstances
1993, 5 of the existing 10 Boraflex
During a period from August 17 through 19, 4 being full-length coupons
coupons were removed from the spent fuel pool,
9309070206 tE
Phi funt 3- O7G O1~
IN 93-70
September 10, 1993 and 1 a short-set coupon (see Figure 1). During
removal of the full-length
coupons a powdery substance and a grey debris cloud
were observed emanating
from the coupons. Further investigation of the full-length
that one coupon had lost an estimated 90 percent coupons revealed
of its Boraflex, two others
50 percent, and one 38 percent. Investigation of
that it had retained 100 percent of its Boraflex. the short-set coupon showed
that the Boraflex in the 4 full-length coupons and The licensee has determined
from different lots of material. the short-set coupon came
A principal difference between the short-set and
the full-length coupons is
their geometrical design. The short-set coupon consists
encapsulating the Boraflex with pool water accessing of eight compartments
coupons. However, in the full-length coupon Boraflex only the edges of the
over the entire length of coupon and bolted between is sandwiched axially
stainless steel metal strips. The licensee postulated two 0.51-mm [0.020-inch]
of the full-length coupon was exposed to the pool that a much larger area
In addition, the full-length coupon has a 12.7-mm water environment and flow.
metal strip on the top portion of the coupon, which [0.5-inch] hole through the
water flow around the Boraflex. The licensee has contributes to the pool
removal or testing of the remaining five coupons no immediate plans for
does intend to conduct neutron "blackness" testing in the spent fuel pool, but
in the spring of 1994.
The licensee also had initiated measurements of
the
spent fuel pool water. No increase in silica above silica content of the
been observed except in instances when the pool boronnormal 1-4 ppm levels have
increased. Because silica filler material is a concentration was
constituent
presence of silica in the water may be an indication of Boraflex, the
Boraflex in the fuel pool. of degradation of the
Discussion
Potential degradation mechanisms for Boraflex include
changes the material characteristics of the base (1) gamma flux, which
environment, namely the accessibility of water to polymer, and (2) chemical
has not drawn firm conclusions as to (1) the root the Boraflex. The licensee
degradation of Boraflex in the coupons, or (2) cause of the observed
the
of Boraflex in the coupons to that in the storage correlation of the behavior
racks.
Degradation of the Boraflex in fuel storage racks
subcriticality margin in the spent fuel pool. The could reduce the
5 percent subcriticality margin on the basis of design basis assumes a
boron concentration in the pool water, and minimumlowest pool temperature, no
assemblies. In its preliminary analysis, the licensee spacing between fuel
pool water and a complete loss of Boraflex from assumed no boron in the
reduced the subcriticality margin from greater the fuel storage racks. This
than 5 percent to about
2 percent. However, the licensee used the burnup
fuel in the criticality calculation. This is higher for the currently stored
value, implying less reactive fuel in the fuel pool than the design burnup
calcul ation. than assumed in the design
The licensee took several compensatory measures, operating staff aware not to dilute the spent fuelincluding (1) making the
pool, (2) increasing the
IN 93-70
September 10, 1993 spent fuel pool chemistry sampling frequency to daily, and (3) keeping the
boron concentration in the spent fuel pool above 1800 ppm, which exceeds the
technical specification requirement for boron concentration. With these
precautions a subcriticality margin greater than 5 percent would be
maintained.
Degradation of Boraflex has been previously addressed by NRC in Information
Notice 87-43, "Gaps in Neutron-Absorbing Material in High-Density Spent Fuel
Storage Racks," September 8, 1987. The Electric Power Research Institute, which has been studying this phenomenon for several years, has recently
published an interim report, "Boraflex Test Results and Evaluation,"
TR-101986, February 1993.
This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the technical contacts listed below or the appropriate Office of
Nuclear Reactor Regulation (NRR) project manager.
(~/'
Bran Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Regulatory Regulation
Technical contacts: Kombiz Salehi, RIII
(708) 790-5782 K. I Parczewski, NRR
(301) 504-2705 Larry Kopp, NRR
(301) 504-2879 Vern Hodge, NRR
(301) 504-1861 Attachments:
1. Figure 1, Palisades Boraflex Coupon Types
2. List of Recently Issued NRC Information Notices
IN 93-70
.- tSeptember 10, 1993 spent fuel pool chemistry sampling frequency to daily, and (3) keeping the
boron concentration in the spent fuel pool above 1800 ppm, which exceeds the
technical specification requirement for boron concentration. With these
precautions a subcriticality margin greater than 5 percent would be
maintained.
Degradation of Boraflex has been previously addressed by NRC in Information
Notice 87-43, "Gaps in Neutron-Absorbing Material in High-Density Spent Fuel
Storage Racks," September 8, 1987. The Electric Power Research Institute, which has been studying this phenomenon for several years, has recently
published an interim report, "Boraflex Test Results and Evaluation,"
TR-101986, February 1993.
This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the technical contacts listed below or the appropriate Office of
Nuclear Reactor Regulation (NRR) project manager.
Original signed Uy
Maian K.Grime$
Brian K. Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Regulatory Regulation
Technical contacts: Kombiz Salehi, RIII
(708) 790-5782 K. I Parczewski, NRR
(301) 504-2705 Larry Kopp, NRR
(301) 504-2879 Vern Hodge, NRR
(301) 504-1861 Attachments:
1. Figure 1, Palisades Boraflex Coupon Types
2. List of Recently Issued NRC Information Notices
OFFICE OGCB:DORS:NRR DRS:RIII DD:DRS:RIII SRXB:DSSA:NRR C:SRXB:DSSA:NRR
NAME *CVHodge *KSalehi *WLForney *LIKopp *RCJones
DATE 09/02/93 09/02/93 09/02/93 09/03/93 09/03/93 Tech Ed D:DSSA EMCB:DE:NRR EMCB:DE:NRR C:EMCB:DE:NRR C:OEAB:DORS
- DGable *ACThadani *JStrosnider *KlParczewski *RAHermann *AEChaffee
09/01/93 09/04/93 01J0M22 09/03/93 09/03/93 09/03/93
11 _ _ _ _ ,_
C:OGCB:DORS:NRR
09/03/93 09/7 /93 DOCUMENI NAME: 93-/U.IN
K>
IN 93-xx I
September xx, 1993 This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
one of the technical contacts listed below or the appropriate Office of !
Nuclear Reactor Regulation (NRR) project manager. I
Brian K. Grimes, Director
Division of Operating Reactor Supi 0ort
Office of Nuclear Regulatory Regul at on
Technical Contact:
Kombiz Salehi, RIII
(708) 790-5782 K. I Parczewski, NRR
(301) 504-2705 Larry Kopp, NRR
(301) 504-2879 Vern Hodge, NRR
(301) 504-1861 Attachments: 1. Figure 1, Palisades Boraflex Coupon Types
2. List of Recently Issued NRC Information Notices
- SEE PREVIOUS CONCURRENCE. .. ..... - . . ' - .
at 1 law.
- L/
OFFICE OGCB:DORS:NRR DRS: RI I¢ .RP DD DR4:RIIIr SRXB:DSSA:NRR C:SRXB:DSSA:NRRL
NAME CVHodge KSalehi WLForney LIKop RC ones, DATE O /l2/93 CO/72/93 £ /O2I93 7/3 /93 /3 /93
/9 D:DSS
ACThada i
/ .._.93
/9 r EMCB:DE:NRR
Strosnider
/3/93
_MCB:DE:NRS C:7 XParczewski
'1 /,3/93 §
UNRR
/3/93 D
RAHermann j
IOEAB:DORS
0aefffee
___________
C:OGCB:DORS:NR4 D:DORS:NRR
GHMarcus OI M BKGrimes
q/13 /93 / /93 DOCUMENT NAME: PALN0902.CVH
4Adr of ads? >
.4 A 42XsK 4-ct-M etO 4
vJ
IN 93-xx
September xx, 1993 The licensee took several compensatory measures, including (1) making the
operating staff aware to not dilute the spent fuel pool, (2) increasing the
spent fuel pool chemistry sampling frequency to daily, and (3) keeping the
boron concentration in the spent fuel pool above 1800 ppm, which exceeds the
technical specification requirement for boron concentration.
Degradation of Boraflex has been previously addressed by NRC in Information
Notice 87-43, "Gaps in Neutron-Absorbing Material in High-Density Spent Fuel
Storage Racks," September 8, 1987. The Electric Power Research Institute, who
has been studying this phenomenon for several years, has recently published an
interim report, "Boraflex Test Results and Evaluation," TR-101986, February
1993.
This information notice requires no specific action or written response. If
you have any questions about the information in this notice, please contact
the technical contact listed below or the appropriate Office of Nuclear
Reactor Regulation (NRR) project manager.
Brian K. Grimes, Director
Division of Operating Reactor Support
Office of Nuclear Regulatory Regulation
Technical Contact:
Kombiz Salehi, RIII
(708)790-5782 K. I Parczewski, NRR Larry Kopp, NRR Vern Hodge, NRR
(301) 504-2705 (301) 504-2879 (301) 504-1861 Attachments: 1. Figure 1, Palisades Boraflex Coupon Types
2. List of Recently Issued NRC Information Notices
.3c
LL.
DDVITNIC
UVIRUURAJW
VUL J
rnmriIDDrrr
OFFICE lOGCB:DORS:NRR DRS:RIII D:DRS:RIII SRXB:DSSA:NRR C:SRXB:DSSA:NRR
NAME CVHodge Ug KSalehi TOMartin LIKopp RCJones
DATE Oq/ol0/93 / /93 / /93 /93 /93 Tech Ed D:DSSA EMCB:DE:NRR EMCB:DE:ND C:EMCB:DE:NRR C:OEAB:DORS
q j ACTHADANI JStrosnider KIParczews'ki RAHermann AEChaffee
____ /93 /_/93 /_/93 9 /l/93 /L/93 / /93 C:OGCB:DORS:NRR D:DORS:NRR
GHMarcus [BKGrimes
/ /93 J / /93 DOCUMENT NAME: PALNOFIG.CVH
K-I
Attachment 1 IN 93-70
September 10, 1993 Figure 1_ Q
Palisades Boraflex a. .
Coupon Types Ii
a
I I
Bodfes mate w i
boned bloom two 3i
3_..
I:
I
3
39rIa I - -I
le i 2! Shoet M Pafkn* I
I
i
I4
. . 4
.I I
I
E Li
Axtachment 2 IN 93-70
September 10, 1993 Page 1 of I
LIST OF RECENTLY ISSUED
NRC INFORMATION NOTICES
Information Date of
Notice No. Subject Issuance Issued to
93-69 Radiography Events at 09/02/93 All holders of OLs or CPs
Operating Power Reactors for nuclear power reactors
and all radiography
licensees.
93-68 Failure of Pump Shaft 09/01/93 All holders of OLs or CPs
Coupling Caused by for nuclear power reactors.
Temper Embrittlement
during Manufacture
92-16, Loss of Flow from the 08/23/93 All holders of OLs or CPs
Supp. 2 Residual Heat Removal for nuclear power reactors.
Pump during Refueling
Cavity Draindown
93-67 Bursting of High 08/16/93 All holders of OLs or CPs
Pressure Coolant for nuclear power reactors.
Injection Steam Line
Rupture Discs Injures
Plant Personnel
93-66 Switchover to Hot-Leg 08/16/93 All holders of OLs or CPs
Injection Following for pressurized water
A Loss-of-Coolant reactors.
Accident in Pres- surized Water Reactors
93-65 Reactor Trips Caused 08/13/93 Al 1 holders of OLs or CPs
by Breaker Testing for nuclear power reactors.
with Fault Protection
Bypassed
93-64 Periodic Testing and 08/12/93 All holders of OLs or CPs
Preventive Maintenance for nuclear power reactors.
of Molded Case Circuit
Breakers
93-63 Improper Use of Soluble 08/11/93 All holders of OLs or CPs
Weld Purge Dam Material for nuclear power reactors.
CP = Construction Permit
|
---|
|
list | - Information Notice 1993-01, Accuracy of Motor-Operated Valve Diagnostic Equipment Manufactured by Liberty Technologies (4 January 1993)
- Information Notice 1993-02, Malfunction of a Pressurizer Code Safety Valve (4 January 1993, Topic: Loop seal)
- Information Notice 1993-04, Investigation and Reporting of Misadministrations by the Radiation Safety Officer (7 January 1993)
- Information Notice 1993-05, Locking of Radiography Exposure Devices (14 January 1993, Topic: Uranium Hexafluoride)
- Information Notice 1993-06, Potential Bypass Leakage Paths Around Filters Installed in Ventilation Systems (22 January 1993)
- Information Notice 1993-07, Classification of Transportation Emergencies (1 February 1993)
- Information Notice 1993-08, Failure of Residual Heat Removal Pump Bearings Due to High Thrust Loading (1 February 1993, Topic: Probabilistic Risk Assessment)
- Information Notice 1993-09, Failure of Undervoltage Trip Attachment on Westinghouse Model DB-50 Reactor Trip Breaker (2 February 1993)
- Information Notice 1993-10, Dose Calibrator Quality Control (2 February 1993)
- Information Notice 1993-11, Single Failure Vulnerability of Engineered Safety Features Actuation Systems (4 February 1993)
- Information Notice 1993-12, Off-Gassing in Auxiliary Feedwater System Raw Water Sources (11 February 1993)
- Information Notice 1993-13, Undetected Modification of Flow Characteristics in High Pressure Safety Injection System (16 February 1993)
- Information Notice 1993-14, Clarification of 10 CFR 40.22, Small Quantities of Source Material (18 February 1993)
- Information Notice 1993-15, Failure to Verify the Continuity of Shunt Trip Attachment Contacts in Manual Safety Injection and Reactor Trip Switches (18 February 1993)
- Information Notice 1993-16, Failures of Not-Locking Devices in Check Valves (19 February 1993, Topic: Anchor Darling, Flow Induced Vibration)
- Information Notice 1993-17, Safety Systems Response to Loss of Coolant and Loss of Offsite Power (25 March 1994, Topic: Fire Barrier, Backfit)
- Information Notice 1993-18, Portable Moisture-Density Gauge User Responsibilities During Field Operations (10 March 1993, Topic: Moisture Density Gauge, Moisture-Density Gauge, Stolen)
- Information Notice 1993-19, Slab Hopper Bulging (17 March 1993, Topic: Hydrostatic)
- Information Notice 1993-20, Thermal Fatigue Cracking of Feedwater Piping to Steam Generators (24 March 1993)
- Information Notice 1993-21, Summary of NRC Staff Observations Compiled During Engineering Audits or Inspections of Licensee Erosion/Corrosion Programs (25 March 1993, Topic: Weld Overlay)
- Information Notice 1993-22, Tripping of Klockner-Moeller Molded-Case Circuit Breakers Due to Support Lever Failure (26 March 1993)
- Information Notice 1993-23, Weschler Instruments Model 252 Switchboard Meters (31 March 1993)
- Information Notice 1993-24, Distribution of Revision 7 of NUREG-1021, Operation Licensing Examiner Standards (31 March 1993, Topic: Job Performance Measure)
- Information Notice 1993-25, Electrical Penetration Assembly Degradation (1 April 1993)
- Information Notice 1993-26, Grease Soldification Causes Molded-Case Circuit Breaker Failure to Close (31 January 1994)
- Information Notice 1993-27, Level Instrumentation Inaccuracies Observed During Normal Plant Depressurization (8 April 1993, Topic: Reactor Vessel Water Level)
- Information Notice 1993-28, Failure to Consider Loss of DC Bus in the Emergency Core Cooling System Evaluation May Lead to Nonconservative Analysis (9 April 1993, Topic: Fuel cladding)
- Information Notice 1993-29, Problems with the Use of Unshielded Test Leads in Reactor Protection System Circuitry (12 April 1993)
- Information Notice 1993-30, NRC Requirements for Evaluation of Wipe Test Results; Calibration of Count Rate Survey Instruments (12 April 1993)
- Information Notice 1993-31, Training of Nurses Responsible for the Care of Patients with Brachytherapy Implants (13 April 1993, Topic: Brachytherapy)
- Information Notice 1993-32, Nonconservative Inputs for Boron Dilution Events Analysis (21 April 1993, Topic: Shutdown Margin)
- Information Notice 1993-33, Potential Deficiency of Certain Class Ie Instrumental and Control Cables (28 April 1993)
- Information Notice 1993-33, Potential Deficiency of Certain Class IE Instrumental and Control Cables (28 April 1993, Topic: Brachytherapy)
- Information Notice 1993-34, Potential for Loss of Emergency Cooling Function Due to a Combination of Operational and Post-LOCA Debris in Containment (6 May 1993, Topic: Brachytherapy)
- Information Notice 1993-35, Insights from Common-Cause Failure Events (12 May 1993, Topic: Brachytherapy)
- Information Notice 1993-36, Notifications, Reports, and Records of Misadministrations (7 May 1993, Topic: Brachytherapy)
- Information Notice 1993-37, Eyebolts with Indeterminate Properties Installed in Limitorque Valve Operator Housing Covers (19 May 1993, Topic: Brachytherapy)
- Information Notice 1993-38, Inadequate Testing of Engineered Safety Features Actuation Systems (24 May 1993)
- Information Notice 1993-39, Radiation Beams From Power Reactor Biological Shields (25 May 1993)
- Information Notice 1993-39, Radiation Beams from Power Reactor Biological Shields (25 May 1993)
- Information Notice 1993-40, Fire Endurance Test Results for Thermal Ceramics FP-60 Fire Barrier Material (26 May 1993, Topic: Safe Shutdown, Fire Barrier, Fire Protection Program)
- Information Notice 1993-41, One Hour Fire Endurance Test Results for Thermal Ceramics Kaowool, 3M Company FS-195 and 3M Company Interam E-50 Fire Barrier Systems (28 May 1993, Topic: Safe Shutdown, Fire Barrier)
- Information Notice 1993-42, Failure of Anti-Rotation Keys in Motor-Operated Valves Manufactured by Yelan (9 June 1993)
- Information Notice 1993-43, Use of Inappropriate Lubrication Oils in Satety-Related Applications (10 June 1993)
- Information Notice 1993-44, Operational Challenges During a Dual-Unit Transient (15 June 1993)
- Information Notice 1993-45, Degradation of Shutdown Cooling System Performance (16 June 1993)
- Information Notice 1993-46, Potential Problem with Westinghouse Rod Control System and Inadvertent Withdrawal of Single Rod Control Cluster Assembly (10 June 1993)
- Information Notice 1993-47, Unrecognized Loss of Control Room Annunciators (18 June 1993)
- Information Notice 1993-48, Failure of Turbine-Driven Main Feedwater Pump to Trip Because of Contaminated Oil (6 July 1993)
- Information Notice 1993-49, Improper Integration of Software Into Operating Practices (8 July 1993)
... further results |
---|