MONTHYEARInformation Notice 1990-15, Reciprocity Notification of Agreement State Radiation Control Directors Before Beginning Work in Agreement States1990-03-17017 March 1990 Reciprocity Notification of Agreement State Radiation Control Directors Before Beginning Work in Agreement States Information Notice 1990-18, Potential Problems With Crosby Safety Relief Valves Used on Diesel Generator Air Start Receiver Tanks1990-03-0909 March 1990 Potential Problems With Crosby Safety Relief Valves Used on Diesel Generator Air Start Receiver Tanks Information Notice 1990-18, Potential Problems with Crosby Safety Relief Valves Used on Diesel Generator Air Start Receiver Tanks1990-03-0909 March 1990 Potential Problems with Crosby Safety Relief Valves Used on Diesel Generator Air Start Receiver Tanks Information Notice 1990-17, Weight and Center of Gravity Discrepancies for Copes-Vulcan Valves1990-03-0808 March 1990 Weight and Center of Gravity Discrepancies for Copes-Vulcan Valves Information Notice 1990-16, Compliance with New Decommissioning Rule1990-03-0707 March 1990 Compliance with New Decommissioning Rule Information Notice 1990-14, Accidental Disposal of Radioactive Materials1990-03-0606 March 1990 Accidental Disposal of Radioactive Materials Information Notice 1990-13, Importance of Review and Analysis of Safeguards Event Logs1990-03-0505 March 1990 Importance of Review and Analysis of Safeguards Event Logs Information Notice 1990-11, Maintenance Deficiency Associated with Solenoid-Operated Valves1990-02-28028 February 1990 Maintenance Deficiency Associated with Solenoid-Operated Valves Information Notice 1990-12, Monitoring or Interruption of Plant Communications1990-02-28028 February 1990 Monitoring or Interruption of Plant Communications Information Notice 1990-09, Extended Interim Storage of Low-Level Radioactive Waste by Fuel Cycle and Materials Licensees1990-02-0505 February 1990 Extended Interim Storage of Low-Level Radioactive Waste by Fuel Cycle and Materials Licensees Information Notice 1990-08, KR-85 Hazards From Decayed Fuel1990-02-0101 February 1990 KR-85 Hazards From Decayed Fuel Information Notice 1990-08, KR-85 Hazards from Decayed Fuel1990-02-0101 February 1990 KR-85 Hazards from Decayed Fuel Information Notice 1990-07, New Information Regarding Insulation Material Performance and Debris Blockage of PWR Containment Sumps1990-01-30030 January 1990 New Information Regarding Insulation Material Performance and Debris Blockage of PWR Containment Sumps Information Notice 1990-06, Potential for Loss of Shutdown Cooling While at Low Reactor Coolant Levels1990-01-29029 January 1990 Potential for Loss of Shutdown Cooling While at Low Reactor Coolant Levels Information Notice 1990-05, Inter-System Discharge of Reactor Coolant1990-01-29029 January 1990 Inter-System Discharge of Reactor Coolant Information Notice 1990-03, Malfunction of Borg-Warner Bolted Bonnet Check Valves Caused by Failure of the Swing Arm1990-01-23023 January 1990 Malfunction of Borg-Warner Bolted Bonnet Check Valves Caused by Failure of the Swing Arm Information Notice 1990-02, Potential Degradation of Secondary Containment1990-01-22022 January 1990 Potential Degradation of Secondary Containment Information Notice 1990-01, Importance of Proper Response to Self-Identified Violations by Licensees1990-01-12012 January 1990 Importance of Proper Response to Self-Identified Violations by Licensees Information Notice 1989-89, Event Notification Worksheets1989-12-26026 December 1989 Event Notification Worksheets Information Notice 1989-88, Recent NRC-Sponsored Testing of Motor-Operated Valves1989-12-26026 December 1989 Recent NRC-Sponsored Testing of Motor-Operated Valves Information Notice 1989-87, Disabling of Emergency Diesel Generators by Their Neutral Ground-Fault Protection Circuitry1989-12-19019 December 1989 Disabling of Emergency Diesel Generators by Their Neutral Ground-Fault Protection Circuitry Information Notice 1989-85, Epa'S Interim Final Rule on Medical Waste Tracking and Management1989-12-15015 December 1989 Epa'S Interim Final Rule on Medical Waste Tracking and Management Information Notice 1989-86, Type Hk Circuit Breakers Missing Close Latch Anti-Shock Springs1989-12-15015 December 1989 Type Hk Circuit Breakers Missing Close Latch Anti-Shock Springs Information Notice 1989-83, Sustained Degraded Voltage on the Offsite Electrical Grid and Loss of Other Generating Stations as a Result of a Plant Trip1989-12-11011 December 1989 Sustained Degraded Voltage on the Offsite Electrical Grid and Loss of Other Generating Stations as a Result of a Plant Trip Information Notice 1989-83, Sustained Degraded Voltage on the Offsite Electrical Grid and Loss of Other Generating Stations As a Result of a Plant Trip1989-12-11011 December 1989 Sustained Degraded Voltage on the Offsite Electrical Grid and Loss of Other Generating Stations As a Result of a Plant Trip Information Notice 1989-82, Recent Safety-Related Incidents at Large Irradiators1989-12-0707 December 1989 Recent Safety-Related Incidents at Large Irradiators Information Notice 1989-59, Suppliers of Potentially Misrepresented Fasteners1989-12-0606 December 1989 Suppliers of Potentially Misrepresented Fasteners Information Notice 1989-81, Inadequate Control of Temporary Modifications to Safety-Related Systems1989-12-0606 December 1989 Inadequate Control of Temporary Modifications to Safety-Related Systems Information Notice 1989-80, Potential for Water Hammer, Thermal Strafication, and Steam Binding in High-Pressure Coolant Injection Piping1989-12-0101 December 1989 Potential for Water Hammer, Thermal Strafication, and Steam Binding in High-Pressure Coolant Injection Piping Information Notice 1989-79, Degraded Coatings and Corrosion of Steel Containment Vessels1989-12-0101 December 1989 Degraded Coatings and Corrosion of Steel Containment Vessels Information Notice 1989-56, Questionable Certification of Material Supplied to the Defense Dept. by Nuclear Suppliers1989-11-22022 November 1989 Questionable Certification of Material Supplied to the Defense Dept. by Nuclear Suppliers Information Notice 1989-56, Questionable Certification of Material Supplied to the Defense Dept. By Nuclear Suppliers1989-11-22022 November 1989 Questionable Certification of Material Supplied to the Defense Dept. By Nuclear Suppliers Information Notice 1989-78, Failure of Packing Nuts on One-Inch Uranium Hexafluoride Cylinder Valves1989-11-22022 November 1989 Failure of Packing Nuts on One-Inch Uranium Hexafluoride Cylinder Valves Information Notice 1989-76, Biofouling Agent: Zebra Mussel1989-11-21021 November 1989 Biofouling Agent: Zebra Mussel Information Notice 1989-77, Debris in Containment Emergency Sumps and Incorrect Screen Configurations1989-11-21021 November 1989 Debris in Containment Emergency Sumps and Incorrect Screen Configurations Information Notice 1989-75, Falsification of Welder Qualifications for Contractor Employees1989-11-20020 November 1989 Falsification of Welder Qualifications for Contractor Employees Information Notice 1989-74, Clarification of Transportation Requirements Applicable to Return of Spent Radiopharmacy Dosages from Users to Suppliers1989-11-0707 November 1989 Clarification of Transportation Requirements Applicable to Return of Spent Radiopharmacy Dosages from Users to Suppliers Information Notice 1989-73, Potential Overpressurization of Low Pressure Systems1989-11-0101 November 1989 Potential Overpressurization of Low Pressure Systems Information Notice 1989-72, Failure of Licensed Senior Operators to Classify Emergency Events Properly1989-10-24024 October 1989 Failure of Licensed Senior Operators to Classify Emergency Events Properly Information Notice 1989-71, Diversion of the Residual Heat Removal Pump Seal Cooling Water Flow During Recirculation Operation Following a Loss-Of-Coolant Accident1989-10-19019 October 1989 Diversion of the Residual Heat Removal Pump Seal Cooling Water Flow During Recirculation Operation Following a Loss-Of-Coolant Accident Information Notice 1989-70, Possible Indications of Misrepresented Vendor Products1989-10-11011 October 1989 Possible Indications of Misrepresented Vendor Products Information Notice 1989-68, Evaluation of Instrument Setpoints During Modifications1989-09-25025 September 1989 Evaluation of Instrument Setpoints During Modifications Information Notice 1989-67, Loss of Residual Heat Removal Caused by Accumulator Nitrogen Injection1989-09-13013 September 1989 Loss of Residual Heat Removal Caused by Accumulator Nitrogen Injection Information Notice 1989-66, Qualification Life of Solenoid Valves1989-09-11011 September 1989 Qualification Life of Solenoid Valves Information Notice 1989-65, Potential for Stress Corrosion Cracking in Steam Generator Tube Plugs Supplied by Babcock and Wilcox1989-09-0808 September 1989 Potential for Stress Corrosion Cracking in Steam Generator Tube Plugs Supplied by Babcock and Wilcox Information Notice 1989-64, Electrical Bus Bar Failures1989-09-0707 September 1989 Electrical Bus Bar Failures Information Notice 1989-63, Possible Submergence of Electrical Circuits Located Above the Flood Level Because of Water Intrusion and Lack of Drainage1989-09-0505 September 1989 Possible Submergence of Electrical Circuits Located Above the Flood Level Because of Water Intrusion and Lack of Drainage Information Notice 1989-62, Malfunction of Borg-Warner Pressure Seal Bonnet Check Valves Caused by Vertical Misalignment of Disk1989-08-31031 August 1989 Malfunction of Borg-Warner Pressure Seal Bonnet Check Valves Caused by Vertical Misalignment of Disk Information Notice 1989-61, Failure of Borg-Warner Gate Valves to Close Against Differential Pressure1989-08-30030 August 1989 Failure of Borg-Warner Gate Valves to Close Against Differential Pressure Information Notice 1989-58, Disablement of Turbine-Driven Auxiliary Feedwater Pump Due to Closure of One of the Parallel Steam Supply Valves1989-08-0303 August 1989 Disablement of Turbine-Driven Auxiliary Feedwater Pump Due to Closure of One of the Parallel Steam Supply Valves 1990-03-09
[Table view] |
SSINS: 6870
Accession No:
7908220108 UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555 September 7, 1979 -
IE Information Notice No. 79-20 Rev. 1 NRC ENFORCEMENT POLICY - NRC LICENSED INDIVIDUALS
Background:
In the past, NRC licensed individuals have been cited by the NRC for failure
to comply with the conditions of their licenses. These items of noncompliance
can generally be characterized as serious or repeated failures to follow
reactor operating procedures. Two recent events involving the radiation
overexposure of NRC licensed individuals through their violation of utility
procedures, facility Technical Specifications and the Code of Federal Regulations
have raised questions about the exercise of their responsibilities.
The purpose of this Information Notice is two-fold:
(1) To remind the NRC licensed individuals of their responsibilities, not only
in the proper operation of the facility controls, but in compliance with
the facility administrative procedures, and
(2) To summarize the enforcement sanctions available to the NRC for use
against licensed individuals.
Description of Circumstances
1. Responsibilities
Facility licensees are charged with the responsibility to design, construct and operate their plants in accordance with NRC requirements
to assure that public health and safety are protected. The role of
NRC licensed individuals is no less important in the overall Regulatory
scheme. The NRC recognizes that timely actions by NRC licensed indivi- duals are an important part of safety. Reliance on these actions is a
part of the defense-in-depth concept. Specifically, the NRC requires
that:
(1) Only licensed operators are permitted to manipulate the controls
that directly affect reactivity (10 CFR 50.54 (i))
(2) Licensed operators are required to be present at the controls at
all times during the operation of the facility (10 CFR 50.54 (k))
-IE Information Notice No. 79-20 Rev. 1 September 7, 1979 (3) Operation of mechanisms and apparatus other than controls which may
indirectly affect the power level or reactivity of a reactor shall
only be accomplished with the knowledge and consent of an operator
licensed in accordance with Part 55 (10 CFR 50.54 (j))
(4) Licensed senior operators are required to be present at the facility
during specified conditions, and available or on call at other times
during operation (10 CFR 50.54 (m))
(5) The NRC licensed individual shall observe all applicable rules, regulations and orders of the Commission, whether or not stated in
the license (10 CFR 55.31(d))
The above requires the NRC licensed individual to comply with the requirements
pertaining to the operation of the facility and manipulation of its controls
and to comply-with radiation safety procedures implementing 10 CFR 20.
NRC policy for the responsibility for safe operation of NRC licensed facilities
continues to be as follows:
(1) The facility licensee is responsible for assuring that the facility is
operated within the requirements of the license, Technical Specifica- tions, rules, regulations, and Orders of the NRC and for the actions of
their employees.
(2) NRC licensed individuals are responsible for taking timely and
proper actions so as not to create or cause a hazard to "safe opera- tion of the facility" (i.e. actions or activities, including failure
to take action, related to the facility which could have an adverse
affect on the health and safety of the public, plant workers or the
individuals).
2. Enforcement Sanctions
On December 31, 1974, the then AEC sent a letter to all facility licensees
containing the criteria for determining enforcement action and the categories
of noncompliance with AEC regulatory requirements. Those criteria and
categories are applicable to NRC licensed individuals as well as facility
licensees.
Paragraph 55.40(b) of Title 10 of the Code of Federal Regulations
prescribes that NRC issued operator licenses may be revoked, suspended or
modified for failure to observe any terms or conditions of any rule, regulation or Order of the Commission, or any conduct determined to be a
hazard to safe operation of the facility. These would generally involve
serious items of noncompliance where: (1) the individuals' action clearly
demonstrate inattention to duties or disregard for requirements including
technical specificatons and operating procedures; (2) the NRC licensed
individual fails to take a required action or takes an independent action
-that results insigniticant actual or potential safety consequences; or
(3) there is repetitive noncompliance with regulatory requirements.
IE tnformation Notice No. 79-20 Rev. 1 September 7, 1979 Examples of situations which could result in violations include:
(1) Noting a serious violation of procedural requirements and not taking
corrective action.
(2) Unauthorized bypassing of required reactor safety systems
(3) Defeating alarms which have serious safety significance
(4) Unauthorized abandoning of reactor controls
(35) Knowingly taking actions that violate TS Limiting Conditions for
Operation
The examples listed above involve the failure of an NRC licensed individual to
follow procedures and adhere to controls. These are violations of NRC require- ments. In the past the NRC has issued Notices of Violation, as provided for in
10 CFR 2.201, and suspended, modified or revoked the license, as provided for
in 10 CFR 55.40 (b), of NRC licensed individuals. The issuance of civil
monetary penalties, as provided for in 10 CFR 2.205 and 10 CFR 55.50, or
criminal charges, as provided for in 10 CFR 55.50, have not been previously
used against NRC licensed individuals but may be used if the circumstances
warrant such action.
The Commission will continue to monitor the performance of NRC licensed
individuals and will continue to take the appropriate enforcement action
against NRC licensed individuals.
No written response to this Information Notice is required. If you have
questions regarding this matter, please contact the Director of the appro- priate NRC Regional Office.
|
---|
|
list | - Information Notice 1979-01, Bergen-Paterson Hydraulic Shock & Sway Arrestors (Hssa) (2 February 1979)
- Information Notice 1979-01, Bergen-Paterson Hydraulic Shock & Sway Arrestors (HSSA) (2 February 1979)
- Information Notice 1979-03, Limitorque Valve Geared Limit Switch Lubricant (9 February 1979)
- Information Notice 1979-04, Degradation of Engineered Safety Features (16 February 1979)
- Information Notice 1979-05, Use of Improper Materials in Safety-Related Components (21 March 1979)
- Information Notice 1979-06, Stress Analysis of Safety-Related Piping (23 March 1979, Topic: Earthquake)
- Information Notice 1979-07, Rupture of Radwaste Tanks (26 March 1979)
- Information Notice 1979-08, Interconnection of Contaminated Systems with Service Air Systems Used as Source of Breathing Air (28 March 1979)
- Information Notice 1979-08, Interconnection of Contaminated Systems With Service Air Systems Used As Source of Breathing Air (28 March 1979)
- Information Notice 1979-09, Spill of Radioactively Contaminated Resin (30 March 1979, Topic: Hydrostatic)
- Information Notice 1979-19, Pipe Cracks in Stagnant Borated Water Systems at PWR Plants (17 July 1979, Topic: Boric Acid, Hydrostatic, Liquid penetrant)
- Information Notice 1979-20, NRC Enforcement Policy - NRC Licensed Individuals (7 September 1979)
- Information Notice 1979-21, Transportation & Commercial Burial of Radioactive Material (7 September 1979)
- Information Notice 1979-22, Qualification of Control Systems (14 September 1979)
- Information Notice 1979-24, Overpressurization of Containment of a PWR Plant After a Main Steam Line Break (1 October 1979)
- Information Notice 1979-25, Reactor Trips at Turkey Point Units 3 & 4 (1 October 1979)
- Information Notice 1979-26, Breach of Containment Integrity (5 November 1979)
- Information Notice 1979-28, Overloading of Structural Elements Due to Pipe Support Loads (16 November 1979)
- Information Notice 1979-29, Loss of Nonsafety-Related Reactor Coolant System Instrumentation During Operation (16 November 1979)
- Information Notice 1979-30, Reporting of Defects & Noncompliances, 10 CFR Part 21 (6 December 1979)
- Information Notice 1979-31, Use of Incorrect Amplified Response Spectra (13 December 1979)
- Information Notice 1979-32, Separation of Electrical Cables for HPCI and ADS (21 December 1979, Topic: Fire Watch)
- Information Notice 1979-33, Improper Closure of Primary Containment Equipment Access Matches (21 December 1979)
- Information Notice 1979-34, Inadequate Design of Safety-Related Heat Exchangers (27 December 1979)
- Information Notice 1979-35, Control of Maintenance & Essential Equipment (31 December 1979)
- Information Notice 1979-36, Computer Code Defect in Stress Analysis of Piping Elbow (31 December 1979)
- Information Notice 1979-37, Cracking in Low Pressure Turbine Discs (28 December 1979, Topic: Turbine Missile)
|
---|