IR 05000482/1978013

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in IE Insp Rept 50-482/78-13. Requests Addl Info Re Failure to Complete User Tests within Time Limits
ML19270G149
Person / Time
Site: Wolf Creek 
Issue date: 04/26/1979
From: Seidle W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Koester G
KANSAS GAS & ELECTRIC CO.
Shared Package
ML19270G150 List:
References
NUDOCS 7906050056
Download: ML19270G149 (1)


Text

7 4B 6 e* * 8 %g UNITE D STATES o

NUCLE AR REGULATORY COMMISSION 35%.\\

n

REGION IV

I

$

611 RYAN PLAZA DRIVE,SulTE 1000

  1. -

!

ARLINGTON, TEXAS 76011 o

,/

%

..s 9 *****

April 26, 1979 In Reply Refer To:

RIV

,

Docket tio. STfl 50-482/Rpt. 78-13 Kansas Gas and Electric Company ATTit:

Mr. Glenn L. Koester Vice President-0perations Post Office Box 208 Wichita, Kansas 67201 Gentlemen:

Thank you for your letter of March 22, 1979, in response to our letter dated February 16, 1979, and the attached flotice of Violation.

As a result of our review, we find that additional information is needed.

Specifically, in your response to finding flo. 4, " Failure to Complete User Tests Within Time Limits," you indicated that your constructor (DIC)

and AE (Bechtel) regard the time limits of ASTM C-150 (paragraph 10-1977 edition) as a minimum, and you indicate that no violation (of procedures)

has occurred. Since it is our position that the time limitations for testing are clearly stated in ASTM C-150, please provide the basis for your interpretation.

.

Sincerely,

_

s

-

.

_-

,

W.C.Seidh, Chief Reactor Construction and Engineering Support Branch

.

7906050o56-