IR 05000416/1986005

From kanterella
Jump to navigation Jump to search
Partially Withheld Physical Security Insp Rept 50-416/86-05 on 860310-13 (Ref 10CFR2.790 & 73.21).No Violations Noted. Major Areas Inspected:Security Plan,Mgt Effectiveness, Security Program & Organization & Records & Repts
ML20205N419
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 04/17/1986
From: Masnyk O, Mcguire D, Thompson D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20205N409 List:
References
50-416-86-05, 50-416-86-5, NUDOCS 8605020129
Download: ML20205N419 (1)


Text

--

-.

,

-

/' pn tr4 UNITED STATES

'o NUCLEAR REGULATORY COMMISSION

,8 REGION 11

,

g j

101 MARIETTA STREET, N.W.

. *

ATL ANTA, GEORGI A 30323

%,,,,/

APR 251986 Report No. 50-416/86-05 Licensee: Mississippi Power and Light Company P. O. Box 23054 Jackson, MS 39205 Docket No. 50-416 License No. NPF-29 Facility Name:

Grand Gulf Unit 1 Inspection Date:

March 10-13, 1986 Inspector:

,I!

n)'

F D. H. Thompson,/ Physical Security Inspector Ddte '5igned DY ll $

n 0. M.'Ma k, Physical Security Inspector

'Date Signed Approved-by:

.

/J/[6

~

D. R. McGuire, Chief, Physical Security Section Uqte~6igned Neclear Materials Safety and Safeguards Branch Division of Radiation Safety and Safeguards

.

SUMMARY Scope:

This unannounced physical security inspection involved 42 inspector-hours (2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> on backshift) inspecting:

Security Plan; Management

'

Effectiveness - Security Program; Security Organization; Records and Reports; Physical Barriers - Protected Area; Physical Barriers - Vital Areas; L-Compensatory Measures; Assessment Aids; Access Control - Personnel; Access Control - Packages; Access Control - Vehicles; Detection Aids - Protected Areas; Detection Aids - Vital Areas; Alarm Stations; and Communications.

Results:

No violations of regulatory requirements were identified in the

.15 areas inspected.

ENCLOSURE CONTAINS\\

SAFEGUARDS INFOP.MATION UPON SEPARATION TNIS PACE IG DICONIHOLLED.

g gy

6 G

-

s