Cyber Security Inspection Report 05000400/2025403 (Public)
ML25162A006
Person / Time
Site: Harris 
(NPF-063)
Issue date: 06/12/2025
From: Daniel Bacon
NRC/RGN-II/DORS/EB1
To: Faulk L
Duke Energy Progress
References
IR 2025403
Download: ML25162A006 (1)


Text

SUBJECT:

SHEARON HARRIS NUCLEAR POWER PLANT - CYBER SECURITY INSPECTION REPORT 05000400/2025403

Dear Linwood Faulk:

On May 8, 2025, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Shearon Harris Nuclear Power Plant and discussed the results of this inspection with Thomas Haaf, Site Vice President and other members of your staff. The results of this inspection are documented in the enclosed report.

Four findings of very low security significance (Green) are documented in this report. Four of these findings involved violations of NRC requirements. We are treating these violations as non-cited violations (NCVs) consistent with Section 2.3.2 of the Enforcement Policy.

If you contest the violations or the significance or severity of the violations documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region II; the Director, Office of Enforcement; the Director, Office of Nuclear Security and Incident Response; and the NRC Resident Inspector at Shearon Harris Nuclear Power Plant.

The following cross cutting aspects were assigned to findings using Inspection Manual Chapter 0310 Aspects Within Cross Cutting Areas: one [H.12] - Avoid Complacency, one [H.13] -

Consistent Process, and two [H.3] - Change Management.

If you disagree with a cross-cutting aspect assignment in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region II; the Director, Office of Nuclear Security and Incident Response; and the NRC Resident Inspector at Shearon Harris Nuclear Power Plant.

This letter will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in June 12, 2025 accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

The enclosed report contains Security-Related Information, so the enclosed report will not be made publicly available in accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390(d)(1). If you choose to provide a response that contains Security-Related Information, please mark your entire response Security-Related Information-Withhold from public disclosure under 10 CFR 2.390 in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390(b)(1). The NRC is waiving the affidavit requirements for your response in accordance with 10 CFR 2.390(b)(1)(ii).

Sincerely, Daniel M. Bacon, Chief Engineering Branch 2 Division of Operating Reactor Safety Docket No. 05000400 License No. NPF-63 Enclosure:

As stated cc w/o encl: Distribution via LISTSERV Signed by Bacon, Daniel on 06/12/25

ML25162A008 (Cover letter w/ enclosure(s))

ADAMS ACCESSION NUMBER: ML25262A006 (Cover letter)

Entire Report:

X SUNSI Review X Non-Sensitive Sensitive X Publicly Available Non-Publicly Available Cover Letter Only:

X SUNSI Review Non-Sensitive X Sensitive Publicly Available X Non-Publicly Available OFFICE RII/DORS RII/DORS RII/DORS NAME L. JONES W. STUCKART D. BACON DATE 06/11/25 06/11/25 06/12/25