IR 05000400/1996004

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-400/96-04
ML18012A294
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 06/27/1996
From: Shymlock M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Robinson W
CAROLINA POWER & LIGHT CO.
References
NUDOCS 9607110121
Download: ML18012A294 (8)


Text

ca.'j:auU~ Y REGULATORv INFORMATION DISTRIBUTION SiSTEM (RIDS)

ACCESSION NBR:9607110121 DOC.DATE: 96/06/27 NOTARIZ"D: NO FACIL:50-400 Shearon Harris Nuclear Power Plant, Un't 1, Carolina

~

~

UTH.NAME AUTHOR AFFILIATION YMLOCK,M.B.

Region 2 (Post 820201)

RECIP.NAME RECIPI"NT AFFILIATiON ROBINSON,W.R.

Carolina Power

! Light Co.

SUBJECT:

Ack receipt of 960618 ltr informing NRC of steps taken to correct violations noted in insp rept 50-400/96-04.

DISTRIBUTION CODE:

IE01D COPIES RECEIUED:LTR ENCL SIZE:

TITLE: General (50 Dkt)-Insp Rept/Notic of Vio ation R sponse NOTES:Application for permit renewal filed.

DOCKET g

05000400 C

T 05000400 E

RECIPIENT ID CODE/NAME PD2-1 PD INTERNAL: ACRS AEOD/TTC L

CE EP NRR/DRCH HHFB NRR/DRPM/PERB OE DIR RGN2 FILE

COPIES LTTR ENCL

1

2

1

1

1

1

1

1 RECIPIENT ID CODE/NAME LEiN AEOD/SPD/RAB DEDRO NRR/DISP/PIPB NRR/DRPM/PECB NUDOCS-ABSTRACT OGC/HDS2 COPIES LTTR ENCL

1

1

1

1

1

1 Q

R Y

E RNAL LITCO BRYCEIJ H

NRC PDR

1

1 NOAC

1 D

U N

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!

CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN 5D-5(EXT. 415-2083)

TO ELIMINATE YOUR NAME FROM

SUBJECT:

REPORT NO. 50-400/96-04

Dear Mr. Robinson:

Thank you for your response of June 18, 1996, to our letter issued on May 20, 1996, concerning activities conducted at your Harris facility.

We have evaluated your response and found that it meets the requirements of

CFR 2.201.

We will examine the implementation of your corrective actions during future inspections.

We appreciate your cooperation in this matter.

Sincerely, (Original signed by G. Belisle)

Docket No. 50-400 License No. NPF-63 Milton B. Shymlock, Chief Reactor Projects Branch

Division of Reactor Projects CC:

J.

Cowan, Manager Operations

& Environmental Support MS OHS7 Carolina Power

& Light Company P. 0.

Box 1551 Raleigh, NC 27602 J.

W. Donahue Plant Manager - Harris Plant Carolina Power

& Light Company S. Harris Nuclear Power Plant P. 0.

Box 165, MC:

Zone

New Hill, NC 27562-0165 (cc cont'd See page 2)

1 1 n (3 9 ~>

P607iiOi21 960627 AoaCK 0S000400

PDR

/

CP&L (cc cont'd)

T. D. Walt, Manager Regulatory Affairs Carolina Power

& Light Company Shearon Harris Nuclear Power Plant P. 0.

Box 165, Mail Zone

New Hill, NC 27562-0165 W. D. Johnson, Vice President and Senior Counsel Carolina Power

& Light Co.

P. 0.

Box 1551 Raleigh, NC 27602 Dayne H. Brown, Director Div. of Radiation Protection N. C. Dept. of Environmental Commerce

& Natural Resources P. 0.

Box 27687 Raleigh, NC 27611-7687 Karen E.

Long Assistant Attorney General State of North Carolina P. 0.

Box 629 Raleigh, NC 27602 Public Service Commission State of South Carolina P. 0.

Box 11649 Columbia, SC 29211 Chairman of the North Carolina Utilities Commission P. 0. Box'9510 Raleigh, NC 27626-0510 Robert P.

Gruber Executive Director Public Staff NCUC P. 0.

Box 29520 Raleigh, NC 27626 Uva Holland, Chairman Board of County Commissioners of Chatham County P. 0.

Box 87 Pittsboro, NC 27312

~Illtabb:

(5 pg 3)

CP&L Distribution:

N. Shymlock, RII M. N. Hiller, RII G. A. Hallstrom, RII N. Le, NRR J.

Lenahan, RII W. Rankin, RII D. Thompson, RII R. Aiello, RII PUBLIC NRC Resident Inspector U. S. Nuclear Regulatory Comm.

5421 Shearon Harris Road New Hill, NC 27562-9998

See revious concurrence SIGNATURE NAME GWISEMAN DROBERTS DATE 06 /

/ 98 06/

/96 08/

/96 06 /

/96 YES NO YES

.NO COPY)

YES NO YES NO OFFICIAL RECORD COPY DOCUMENT NAME:

0:iHARRISiESCEHFiRSP9604 HAR 06/

/96 06/

/96 YES NO YES NO

CPKL Distribution:

N. Le, NRR M. Miller, RII J.

Lenahan, RII M. Rankin, RII D. Thompson, RII R. Aiello, RII PUBLIC NRC Resident Inspector U. S. Nuclear Regulatory Comm.

5421 Shearon Harris Road New Hill, NC 27562-9998 SIGNATURE GWISEMAN D

ERTS NAME 06 / c-6/ 96 oe /Xb/

06 /

/96 06/

/96 DATE YES NO ES No YES No YES

COPY'/

OFFICIAL ORO COPY OOCUH AHE:

G:KHARRIS4ESCEHFKRSP9604.HAR oe/

/96 oe/

/96 YES No YES NO

PLANT NANE: HARRIS INSPECTION RPT NO: 50-400 96-04 RESPONSE RECEIVED: RI:6/18/96 RGII:6 25 96 VIOLATION NO: 96-04-02 Mas the Root Cause for the YES Violation Addressed'f no, explain.

Were the Steps Taken Adequate to Steps, have not been fully Correct the Problem and Prevent implemented yet.

However, those Future Violationt steps described in the licensee's response, should correct the problems.

Inspectors will verify prior to closing the violation.

Results Achieved:

For example I:

Hodifications made to the demineralizer skid to eliminate the venting and admission of resin to the floor drain.

Operations procedures were revised accordingly.

For example 2:

Voltmeter switch was replaced and tested with the correct voltage readings.

Additional Corrective Steps That Mill Be Taken:

Example 1:

A "Training Brief" will be distributed to plant management stressing the importance of proper adverse condition and corrective action implementation.

Example 2:

Procedures will be changed to require personnel to verify by signature that N&TE is free from deficiencies that may affect test performance.

A memo to this affect will be issued to plant personnel.

Training will be provided to plant engineering personnel on the specific switch incident, emphasizing the need to include compensatory actions in surveillance procedure when warranted.

Date. of Full Compliance Indicated:

RECOMMENDED ACTIONS:

Response Letter

~Yes, June 3, 1996.

PREPARED BY:

APPROVED BY:

baseman BSymo a e Da e