U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT
.
REGION III
Report No. 50-358/79-24 Docket No. 50-358 License No. CPPR-88 Licensee: Cincinnati Gas and Electric Company 139 East 4th Street Cincinnati, OH 45201 Facility Name:
Wm. H. Zimmer Nuclear Power Station Inspection At:
Wm. H. Zimmer Site, Moscow, OH Inspection Conducted: July 23-25, and July 31 - August 1, 1979 R FU) %-
Inspector:
J. E. Menning dI-/$-79'
RFld S Approved By:
R. F. Warnick, Chief 7-/$-29 Reactor Projects Section 2 Inspection Summary Inspection on July 23-25, 1979, and Meeting on July 31 - August 1, 1979 (Report No. 50-358/79-24)
Areas Inspected: Routine, unannounced inspection of operating and emergency procedures.
In addition, this rept*t documents the meeting between licensee, General Electric, and NRC personnel on July 31 and August 1, 1979 to discuss proposed Zimmer Technical Specifications.
The inspection involved approxi-mately 20 inspector-manhours onsite by one NRC inspector.
The meeting involved 14 manhours onsite by one NRC inspector.
Results No items of noncompliance or deviations were identified.
1051 196 7 909 2 8001-f
.
DETAILS
.
1.
Persons Contacted
- J.
Schott, Station Superintendent P. King, Assistant Station Superintendent R. Link, Operating Supervisor R. Williams, Shift Supervisor
- Denotes those attending the exit in te rview.
2.
Review of Operating and Emergency Procedures The inspector reviewed selected operating and emergency procedures which had been approved by the licensee, a.
Review of the following procedures retulted in comments (noted below).
The inspector will follow the status of the resolution of these con-cerns during future inspections.
OP. E0P. 02 - Small Piping Breaks Inside Primary Containment (Rev. O, May 27, 1979)
This procedure did not require that personnel attempt to isolate the break.
OP. E0P. 05 - Anticipated Transient Wittput Scram (ATWS) (Rev.0, May 31, 1979)
The immediate actions of this procedute Should be resequenced to require that more time consuming methods of inserting control rods are attempted only after methods which can be rapidly accomplished have failed.
OP. E0P. 15 - Loss of Service Water (Rev. O, June 7, 1979)
A statement should be added at the beginning of the supplementary actions of the total loss of service water section of this procedure to insure that personnel are cautioned to be alert for equipment degradation while attempting time consuming efforts to restore service water.
OP. E0P. 16 - Control Rod Malfunction (Rev. O, May 24, 1979)
The section of this procedure covering uncoupled rods should be modified to ensure that control rod insertiens do not result in unacceptable core peaking.
In addition, the section dealing with drif ting control rods should be modified to specify the positions at which involved control rods should be left when drifting continues.
UP. E0P. 24 - Loss of Reactor Building CCW (Rev. O, June 11, 1979)
-2-1051 197
A statement should be added at the beginning of the supplementary actions of the total loss of RBCCW section of this procedure to insure that personnel are cautioned to be alert for equipment degradation while attempting time consuming efforts to restore RBCCW.
.
OP. E0P. 25 - Loss of Reactor Feed Flow (Rev. 0), June 20, 1979)
Step 3.5 of Section A (Loss of One Reactor Feed Pump) should be expanded to provide guidance on how reactor vessel level is to be returned to normal.
In addition, Steps 3.3 and 3.4 of Section B (Loss of Both Reactor Feed Pumps) should be more explicit as to which sections of the scram and turbine trip procedures apply.
OP. IPOP. 01 - Startup (Rev. O, June 20, 1979)
This procedure should be modified to specify the steps to be followed when establishing a hot standby condition.
In addition, Step 5.6.E should be revised to more clearly indicate the desired IRM range switch position.
b.
Review of the following procedures resulted in either no comments or comments of an editorial nature which were discussed with the licensee.
OP. IPOP. 02 - Normal Power Operations (Rev. O, June 20, 1979)
OP. E0P. 03 - Loss of Coolant Accident (Rev, o, May 15, 1979)
OP. E0P. 04 - Loss of Shutdown Cooling (Rev. O, April 28, 1979)
OP. E0P. 06 - Loss of Primary Containment Integrity (Rev. O, May 1, 1979)
OP. E0P. 07 - Loss of Secondary Containment Integrity (Rev. O, April 28, 1979)
OP. E0P. 08 - Inadvertent Reactivity Addition (Rev. O, Fby 26, 1979)
OP. E0P. 09 - Turbine Generator Trip ( 30% Power) (Rev. O, May 24, 1979)
OP. E0P. 10 - Turbine Generator Trip ( 30% Power) (Rev. o, May 24, 1979)
OP. E0P. 11 - Loss of Recirculation Flow (Rev. O, June 11, 1979)
OP. E0P. 12 - Decreasing Condenser Vacuum (Rev. O, June 20, 1979)
OP. E0P. 13 - Shutdown for Outside Control Room (Rev. O, May 24, 1979)
OP. E0P. 14 - Intrusion of Demineralizer Resin in RPV (Rev.0),
June 11, 1979)
-
-
1051 198
.
OP. E0P. 17 - Fuel Element Failure (Rev. ), May 29, 1979)
'
OP. E0P. 18 - Piping Break Outside Primary Containment (Rev. O, May 25, 1979)
OP. E0P. 19 - Loss of Off Gas (Rev. O, May 25, 1979)
OP. EOP. 20 - Loss of Instrument Air (Rev. O, May 25, 1979 OP. E0P. 21 - Loss of All Auxiliary Power (Rev. O, May 25, 1979)
OP. E0P. 22 - Loss of Reactor Pressure Control (Rev. O, May 24, 1979)
OP. E0P. 23 - Loss of Turbine Building Closed Cooling Water (Rev. O, June 9, 1979)
OP. E0P. 26 - Loss of RPS Channel (Rev. O, June 11, 1979)
OP. E0P. 27 - Emergency Shutdown with SC System (Rev. O, June 7, '.979)
OP. E0P. 28 - Loss of DC Power (Rev. O, June 20, 1979)
No items of noncomplinace or deviations were identified.
3.
Meeting at Zimmer Site on July 31 - August 1, 1979 On July 31 - August 1, 1979, Messrs. J. Menning from Region III and R. Bottimore from NRR met with Mr. P. Hoffmeier and other members of the Zimmer technical staff to discuss proposed Zimmer Technical Specifications. Two representatives of the General Electric Company also participated in these discussions.
4.
Exit Interview The inspector met with Mr. J. Schott at the conclusion of the inspection on July 25, 1979.
The inspector summarized the scope and findings of the inspectica.