IR 05000346/1977013

From kanterella
Jump to navigation Jump to search
IE Insp Rept 50-346/77-13 on 770418-20 & 24-25.No Noncompliance Noted.Major Areas Inspected:New Fuel Insp & Fuel Loading Activities
ML19329B603
Person / Time
Site: Davis Besse 
Issue date: 05/12/1977
From: Creswell J, Little W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19329B428 List:
References
50-346-77-13, NUDOCS 8002050726
Download: ML19329B603 (3)


Text

m

.

.,

.

.

Ae U

U.S. NUCIZAR REGULATORY Com11SSION OFFICE OF INSPECTION AND ENFORCEMENT REGION TII Report No. 50-346/77-13 n-n D

Docket No. 50-346 License No. NFP-3 g g License: Toledo Edison Company O

'D ~9 i

300 Madison Avenue v

-

j[

g Edison Plaza g

,,

Toledo, OH 43562

Facility Name: Davis-Besse Unit 1 Inspection at: Oak Harbor, OH Inspection conducted: April 18-20, 24 and 25, 1977 LW

.5 fig 77 Inspector:

J. S. Creswell f

(date signed)

>]

Approved by: W. S. Little, inf Nucicar Support Section

,(date signed)

,

,, _ _

Inspection Summary Inspection on April 18-20, 24, and 23, 1977 (Report No. 50-346/77-1:0 Areas Inspected,:

Rautina, announced inspection of new fuel inspecLion and fuel loading activities. The inspection invnived 27 1/2 inspector hours onsite by one NRC inspector.

Results: Of the two areas inspected, no items of noncompliance or deviations were identified. One item inspected related to valve line-up was identified as an unresolved item.

V 80090507 %

-

-

_.

.

_

_ _..

________ ___ _ -

m

...

.

.

\\

)

J DETAILS r3 CT' D 1.

Persons Contacted es es P{}

~

7{

A

_

r3 i Principal Licensee Employees D

~(

L

-]

  • J. Evans, Station Superintendant

'#

.,

  • T. Murray, Operations Engineer
  • D. Briden, Chemistry and Health Physics
  • W. Greca, Assistant to Station Superintendent J. Lingenfelter, Nuclear and Performance Engineer The inspector also interviewed 20 other licensee employees during d

the course of the inspection. They included operating personnel, chemistry and health physics personnel and general office personnel.

  • Denotes those present at the exit interview 2.

Licensee Action on Previous Inspection Findings None inspected.

(V'~'}3.

New Fuel Inspection f

The inspector reviewed records of the licensee's inspection of J

i new fuel on receipt at the facility.

No major defects were

!

found during the fuel inspection but small pieces of springs

!

were found and removed from fuel assemblies NJ0028 and NJ0013.

I No items of noncompliance were identified during the inspection of this area.

(

4.

Initial Fuel Loading The inspector reviewed records and proceduren associated with the initial fuel loading operation.

Tn addition, chemistry and opera-ting personnel were interviewed and observed during the fuel loading operation. Licensee compliance with Technical Specifica-tion requirements were also inspected.

During a visit to the control room the inspector discussed Technical Specification requirements asscciated with operable boration paths with the operator. The inspector, while examining the flow paths, asked the operator about the isolation of the reactor coolant ayatem

.j from possible dilution paths. Of particular concern was the iso-lation; of the clean radwante recycle lines from the charging line. An operator was dispatched from the control room to check the valve lineups. He reported that all the necessary valves were closed.

OV-2-

.-

-3.-

I 3)!3)

.\\

D

.

(.q.

I Ct)

D f M]]Jul La

/

F (

@

id d

\\ -

fication List B which was anThis revie The inspector reviewed Valve Veri Further-03.02.1.

positioning.for the subject cnclosure to procedure SP 11 valves were not located for properwas no note of supervisory drein d

This matter is considered unresolve.id solutio

,

more, there

'

volves.

Review of calculations for Boric Ac1977 had several correct a calculation performed April 21,Further discussion form was designed for high nade to the calculational method.ccusee personnel revea were necessary for hat correctionsThe inspector found the calcu-temperature operation and t operations at low temperatures.

lation to be correct.

i Unresolved Item hich more information is items, 5.

whether they are acceptableAn unresolved item Unresolved items are matecrs about w required in order to ascertainitems of noncompliance, or dev i ns.

closed during the inspection is it Interview tativen (denoted in on April 25, The inspector met with licensee represenf the inspectionnd the scope of Paragraph 1) at the conclusion oThe inspector summarized the pur With regard to the perform-stated that the present valve dings.

1977.

the inspection and the finance of valve lineups the licensee With regard to Boric Acid solutionider checkin lineup would be checked. calculations the licensee will cons for the proper method.

m v-3-