$8"'Co UNITED STATES q

y fo NUCLEAR REGULATORY COMMISSION g

y'

g REGION 11

%

j 101 MARIE TT A Sf.. N.W.. SUIT E 3100 g

g ATLANTA. G EORGI A 30303

    • ~

,,,,,

Report Nos. 50-338/81-12 and 50-339/81-09 Licensee: Virginia Electric and Power Company P. O. Box 26666 Richmond, VA 23261 Facility Name: North Anna Units 1 and 2 Docket Nos. 50-338 and 50-339 License Nos. NPF-4 and NPF-7 Inspection at No th Ann site near Mineral, Virginia t

(b-o'

[.

7/ /

Inspector:

_

ymiock '

'

M. B.'

/

Dr te signed a

WI[

Approved by:

b AL

H. C. Dance,'Section Chief, Resident and Dite Signed Reactor Project Inspection Division SUMMARY Inspection on April 27 - May 1,1981 Areas Inspected This routine announced inspection involved 36 inspector-hours on site in the areas of general employee training and facility design changes.

Results

'

Of the two areas inspected, no violations or deviations were identified.

,

0109010586 810730 PDR ADOCK 05000338

PDR

. _..

-.

__..

.._ _- _

..

..

.

. _ -

.. _ -. _ - - -

..

. c>

s

>

DETAILS j

1.

Persons Contacted

.

Licensee Employees

  • B. R. Sylvia, Manager, Nuclear Operations

!

  • E. W. Harrell, Assistant Station Manager

'

  • J. R. Harper, Superintendent Maintenance

"J. W. Martin, Manager, Q/A Manager

  • F. B. Curling, Supervisor Nuclear Training

!

  • A. L. Hogg, Supervisor, Nuclear Training
  • C. R. Swope, Senior QC Inspector

"R. L. Rentz, Resident QC Engineer

  • M. D. Tower, Staff Engineer

R. A. Bergquist, Instrument Supervisor

  • K. A. Huffman, Clerk i

Other licensee employees included technicians, operators, and office personnel.

NRC Resident Inspector

  • E. H. Webster
  • Attended exit interview l

2.

Exit Interview i

The inspection scope and findings were summarized on May 1,1981, with those persons indicated in paragraph 1 above.

The inspector summarized the

purpose and scope of the inspection and ' findings as detailed in the following paragraphs.

l 3.

Licensee Action on Previous Inspection Findings l

Not inspected.

'

4.

Unresolved Items Unresolved items were not identified during this insi ction, 5.

General Employee Training j

I The inspector attended the licensee's general employee training program, which lasted for a day and a half. The program presented was reviewed to determine if it met the established requirements. The areas reviewed were:

administrative controls and procedures, radiological health, security

)

.

l

!

.

.

_

_

._ _. _-. _

.

_

_ _-- _.- _ _.. _ _ ___ - _. _.. _ _ _ - _ _. _ _ _ _. _. _. ~.

.os

.

!

!

,

i i

procedures, emergency plan procedures and proper dressing technique for

.,

i anti-contamination clothes. The presentation was well delivered and no

{

additional concerns were addressed.

i t

6.

Unit 1 Design Change DC 79-565A a

i This design change installed two sub-cooling monitor systems per unit

!

located on the vertical board section 1-1.

These meters are feed from two I

microprocessors located at the left end of the horizonal unit control board.

j Inputs from wide range hot and cold leg temperature loops, wide range j

reactor coolant systems pressure, narrnw range pressurizer pressure and

selected incore thermocouples feed the microprocessors.

These parameters i

are utilized by the microprocessors to calculate the margin to saturation

-

'

l based on existing coolant system pressures and temperature.

Then this

!

information is displayed on the sub-cooling meters.

Additional review of this system are discussed in the resident's Inspection Report 50-338/81-05

!

and 50-339/81-03, Item Number seven.

.

.

'

7.

Inspection Program

l During this inspection the inspector reviewed plant status and outstanding

'

issues with the resident inspector in preparation for assuming inspection

,

responsib)lity.

k

,

i j

.

i

.

i

.

-

!

!

i i

i

!

'

,

f I

.

l

-

I

. -. - -, -. -, -.. - - -...

-. -

. -. -

...

- -.... - - - -. - - - - -. -.