May 10, 2019
SUBJECT:
DIABLO CANYON POWER PLANT, UNITS 1 AND 2 - NRC INTEGRATED INSPECTION REPORT 05000275/2019001 AND 05000323/2019001
Dear Mr. Welsch:
On March 31, 2019, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your Diablo Canyon Power Plant, Units 1 and 2. On April 4, 2019, the NRC inspectors discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.
NRC inspectors documented three findings of very low safety significance (Green) in this report.
Two of these findings involved violations of NRC requirements. The NRC is treating these violations as non-cited violations (NCVs) consistent with Section 2.3.2.a of the Enforcement Policy.
If you contest the violations or significance or severity of the violations documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region IV; the Director, Office of Enforcement; and the NRC resident inspector at the Diablo Canyon Power Plant.
If you disagree with a cross-cutting aspect assignment or a finding not associated with a regulatory requirement in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region IV; and the NRC resident inspector at the Diablo Canyon Power Plant. This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with 10 CFR 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely,
/RA/
Mark S. Haire, Chief Project Branch A Division of Reactor Projects
Docket Nos. 50-275 and 50-323 License Nos. DPR-80 and DPR-82
Enclosure:
Inspection Report 05000275/2019001 and 05000323/2019001 w/attachments:
1. RFI Inservice Inspection 2. RFI O
Inspection Report
Docket Numbers:
05000275 and 05000323
License Numbers:
Report Numbers:
05000275/2019001 and 05000323/2019001
Enterprise Identifier: I-2019-001-0001
Licensee:
Pacific Gas & Electric Company
Facility:
Diablo Canyon Power Plant, Units 1 and 2
Location:
Avila Beach, California
Inspection Dates:
January 1, 2019 to March 31, 2019
Inspectors:
R. Alexander, Senior Project Engineer
B. Baca, Health Physicist
L. Carson, Senior Health Physicist
J. Drake, Senior Reactor Inspector
S. Hedger, Emergency Preparedness Inspector
G. Kolcum, Senior Resident Inspector, Columbia
C. Newport, Senior Resident Inspector
J. Reynoso, Resident Inspector
Approved By:
Mark S. Haire, Chief
Project Branch A
Division of Reactor Projects
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a Quarterly inspection at Diablo Canyon Power Plant, Units 1 and 2, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information. Findings and violations being considered in the NRCs assessment are summarized in the table below.
List of Findings and Violations
Failure to Promptly Correct an Adverse Condition Related to Reactor Coolant Pump Seal Damage Cornerstone Significance Cross-cutting Aspect Report Section Initiating Events Green NCV 05000275/2019001-01 Closed None 71152 The inspectors reviewed a Green, self-revealed non-cited violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, for the licensees failure to promptly identify and correct a condition adverse to quality. Specifically, prior to February 4, 2019, corrective actions generated as a result of a root cause evaluation did not adequately correct a condition adversely impacting reactor coolant pump seals.
Inadequate Corrective Actions Leads to Increased Time at Yellow Risk and Lowered Inventory Cornerstone Significance Cross-cutting Aspect Report Section Initiating Events Green FIN 05000275/2019001-02 Closed
[P.3] - Resolution 71152 The inspectors reviewed a Green, self-revealed finding in that PG&E personnel failed to promptly correct a condition in accordance with OM7.ID1, Problem Identification and Resolution. Specifically, personnel did not promptly correct a condition associated with the Unit 1, polar crane variable frequency drive motor used during the removal and replacement of the reactor vessel head from the reactor vessel during refueling outages that was first identified in 2015. This led to a recent event in which the reactor vessel head was suspended above the reactor vessel during a period of yellow outage safety risk with the reactor vessel water level in lowered inventory condition for approximately 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> longer than necessary.
Human Performance Event Leads to Sodium Hydroxide Leak and Loss of Level Indication for Containment Spray System Spray Additive Tank Cornerstone Significance Cross-cutting Aspect Report Section Mitigating Systems Green NCV 05000323/2019001-03 Closed
[H.12] - Avoid Complacency 71153 The inspectors reviewed a Green, self-revealed non-cited violation of Technical Specification 5.4.1.a, Procedures, because personnel failed to follow the requirements of MP I-12-L931, Spray Additive Tank Level Channel 931 Calibration, Revision 2. Specifically, on March 4, 2019, during calibration of a Unit 2, containment spray additive tank level transmitter, PG&E technicians inadvertently removed a venting plug from the wrong level transmitter resulting in a pressurized leak of sodium hydroxide solution from the spray additive tank and the inability to determine the level of the spray additive.
PLANT STATUS
Units 1 and 2 began the inspection period at full power.
On February 10, 2019, Unit 1 was shut down for a planned refueling outage. On March 16, 2019, Unit 1 returned to operation and began a controlled power ascension, and returned to full power on March 22, 2019.
Units 1 and 2 operated at or near full power for the remainder of the inspection period.
INSPECTION SCOPE
Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors performed plant status activities described in IMC 2515, Appendix D, Plant Status, and conducted routine reviews using IP 71152, Problem Identification and Resolution. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
REACTOR SAFETY
71111.01 - Adverse Weather Protection
Impending Severe Weather Sample (IP Section 03.03) (1 Sample)
The inspectors evaluated readiness for impending adverse weather conditions for high ocean swell and heavy debris loading from ocean storms on January 10-11, 2019.
71111.04 - Equipment Alignment
Partial Walkdown (IP Section 02.01) (5 Samples)
The inspectors evaluated system configurations during partial walkdowns of the following systems/trains:
- (1) Unit 2, residual heat removal train A on January 14, 2019
- (2) Unit 2, emergency diesel generator 2-2 on January 29, 2019
- (3) Unit 2, emergency diesel generator 2-3 on January 29, 2019
- (4) Unit 1, shutdown cooling train B on February 11, 2019
- (5) Unit 1, reactor vessel refueling level indication system on March 8, 2019
71111.05Q - Fire Protection
Quarterly Inspection (IP Section 03.01) (5 Samples)
The inspectors evaluated fire protection program implementation in the following selected areas:
- (1) Unit 2, auxiliary building 100 foot elevation on January 4, 2019
- (2) Units 1 and 2, intake structure on January 16, 2019
- (3) Unit 1, containment 140 foot elevation on February 26, 2019
- (4) Unit 1, containment 91 foot elevation on March 5, 2019
- (5) Unit 1, containment 117 foot elevation on March 5, 2019
71111.07A - Heat Sink Performance
Annual Review (IP Section 02.01) (1 Sample)
The inspectors evaluated readiness and performance of the Unit 1, component cooling water heat exchangers 1-1 and 1-2 on March 13, 2019.
71111.08P - Inservice Inspection Activities (PWR) PWR Inservice Inspection Activities (IP Section 03.01)
The inspectors verified that the reactor coolant system boundary, steam generator tubes, reactor vessel internals, risk-significant piping system boundaries, and containment boundary are appropriately monitored for degradation and that repairs and replacements were appropriately fabricated, examined and accepted by reviewing the following activities from February 18 to February 26, 2019:
03.01.a - Nondestructive Examination and Welding Activities
- (1) Dye Penetrant Examination a) charging and volume control system, CVCS-1-8435, line 1452 b) main feedwater system, main feed pump 1-1 impeller
- (2) Visual Examination a) safety injection system, accumulator fill lines b) auxiliary feedwater system, K-561-8 line c) auxiliary feedwater system, K-6012-8 line d) auxiliary feedwater system, K-638-8 line e) pressurizer system, PZR-8010A studs and nuts
- (3) Ultrasonic Examination a) pressurizer system, girth weld 5
- (4) The inspectors directly observed or reviewed records of the following welding activities:
a) Gas Tungsten Arc Weld - Manual
- chemical volume and control system valve replacement, CVCS-1-8435, line 1452 b) Gas Tungsten Arc Weld - Machine
- Reactor Coolant System. Weld Overlay. Reactor coolant system loop 2A lower cold leg, nozzle to safe-end circumferential weld, WIB-228 03.01.b - Pressurized-Water Reactor Vessel Upper Head Penetration Inspection Activities Vessel upper head penetration inspection was not required to be performed in this outage.
03.01.c - Pressurized-Water Reactor Boric Acid Corrosion Control Activities Inspectors reviewed the following boric acid notifications and corrective actions:
===50956677 50956730 50988345 50927788 50315950 51008168
03.01.d - Steam Generator Tube Inspection Activities The steam generator tube inspections were not required to be performed in this outage.
03.01.e - Identification and Resolution of Problems The inspectors reviewed 19 notifications that dealt with inservice inspection issues and found that items were entered into the corrective action program at the appropriate level and addressed appropriately.
71111.11Q - Licensed Operator Requalification Program and Licensed Operator Performance
Licensed Operator Performance in the Actual Plant/Main Control Room (IP Section 03.01)
=
The inspectors observed and evaluated licensed operator performance in the control room during the following activities:
- (1) Unit 1, plant shutdown for 1R21 refueling outage on February 9-10, 2019
- (2) Unit 2, initiation and alignment of shutdown cooling on February 10, 2019
Licensed Operator Requalification Training/Examinations (IP Section 03.02) (1 Sample)
The inspectors observed and evaluated a crew of licensed operators in the plants simulator during reactor startup training on March 13, 2019.
71111.12 - Maintenance Effectiveness
Routine Maintenance Effectiveness Inspection (IP Section 02.01) (2 Samples)
The inspectors evaluated the effectiveness of routine maintenance activities associated with the following equipment and/or safety significant functions:
- (1) Unit 1, hot work on control room level recorder resulting in blown fuse on January 16, 2019
- (2) Units 1 and 2, safety-related switchgear room ventilation and cooling changes to equipment on March 26, 2019
71111.13 - Maintenance Risk Assessments and Emergent Work Control
Risk Assessment and Management Sample (IP Section 03.01) (3 Samples)
The inspectors evaluated the risk assessments for the following planned and emergent work activities:
- (1) Unit 2, emergency diesel generator 2-1 maintenance outage on January 29-30, 2019
- (2) Unit 1, yellow outage risk during drain down for reactor head removal on February 17, 2019
- (3) Unit 1, yellow outage risk during drain down for reactor head installation on March 8, 2019
71111.15 - Operability Determinations and Functionality Assessments
Sample Selection (IP Section 02.01) (6 Samples)
The inspectors evaluated the following operability determinations and functionality assessments:
- (1) Unit 1, auxiliary saltwater pump 1-1 vital bus 4 kV circuit breaker loose support bolt on January 9, 2019
- (2) Unit 1, elevated reactor coolant system calculated leakage on February 1, 2019
- (3) Unit 1, valve RHR-1-8726B reach rod failure on February 12, 2019
- (4) Unit 1, valve SI-8982A seat leakage on February 15, 2019
- (5) Unit 1, valve RHR-1-8724A bonnet stud material specification on March 5, 2019
- (6) Unit 1, fuel assembly thimble screw missing on March 12, 2019
71111.18 - Plant Modifications
Temporary Modifications and/or Permanent Modifications (IP Section 03.01 and/or 03.02) (1 Sample)
The inspectors evaluated the following temporary or permanent modifications:
- (1) Unit 1, emergency diesel generator 1-2 governor controls upgrade on February 5, 2019
71111.19 - Post Maintenance Testing
Post Maintenance Test Sample (IP Section 03.01) (4 Samples)
The inspectors evaluated the following post maintenance tests:
- (1) Unit 1, vital battery charger 1-2, performance testing and load testing on January 16, 2019
- (2) Unit 1, valve RHR-1-8702, thermal overload device replacement on March 7, 2019
- (3) Unit 1, turbine driven auxiliary feedwater pump 1-1, testing following turbine maintenance on March 16, 2019
- (4) Unit 2, centrifugal charging pump 2-3, testing following maintenance on March 26, 2019
71111.20 - Refueling and Other Outage Activities
Refueling/Other Outage Sample (IP Section 03.01) (1 Sample)
The inspectors evaluated refueling outage 1R21 activities from February 9, 2019 to March 18, 2019.
71111.22 - Surveillance Testing
The inspectors evaluated the following surveillance tests:
Containment Isolation Valve (ISO) (IP Section 03.01) (2 Samples)
- (1) Unit 1, containment integrated leak rate testing, per procedure STP M-7, on February 13, 2019
- (2) Unit 1, containment isolation valve testing of penetration 52B associated with the nitrogen system, per procedure STP V-652B, on February 26, 2019
In Service Testing (IST) (IP Section 03.01) (1 Sample)
Unit 1, comprehensive testing of turbine-driven auxiliary feedwater pump 1-1, per STP P-AFW-PS11, on March 19, 2019
Reactor Coolant System (RCS) Leak Detection (IP Section 03.01) (1 Sample)
Unit 1, reactor coolant leakage and water inventory balance evaluation, per STP I-1A, on January 10, 2019
Surveillance Testing (IP Section 03.01) (3 Samples)
- (1) Unit 1, 12 kV bus reactor coolant pump under-frequency and under-voltage calibration and time response test, per procedure STP I-9, on January 15, 2019
- (2) Unit 1, integrated test of engineered safeguards and diesel generators, per procedure STP M-15, on February 14, 2019
- (3) Unit 1, emergency core cooling system check valve leak test, per procedure STP V-5A1, on March 11, 2019
71114.04 - Emergency Action Level and Emergency Plan Changes
Inspection Review (IP Section 02.01-02.03) (1 Sample)
The licensee submitted a copy of the "Emergency Action Level Technical Basis Manual,"
Appendix D, Revision 5 of the site emergency plan, to the NRC on October 4, 2018. The inspectors conducted an in-office review of the changes from January 25 to February 5, 2019. This evaluation does not constitute NRC approval.
RADIATION SAFETY
71124.01 - Radiological Hazard Assessment and Exposure Controls
Radiological Hazard Assessment (IP Section 02.01) (1 Sample)
The inspectors evaluated radiological hazards assessments and controls. The inspectors reviewed the following documents:
Radiological surveys:
===66011, Weld Overlay
- 65894, Containment
- 66031, Containment
- 66023, Containment
- 65787, Containment
- 65937, Containment Risk significant radiological work activities (Radiation Work Permit (RWP)):
- RWP 19-1004: Weld Overlay
- RWP 19-1006: Pressurizer Boric Acid Removal RCS 1-8054B, 9365B, 8033A
- RWP 19-1023: 1R21 Fuel Movement Dose Rate Verification Air sample survey records:
64476 12/10/18 Particulate Air Sample Filter Storage in Vault 3 61738 05/02/19 17-F-001 Filter Liner Solidification Preps 65063 01/29/19 Weekly D-230 Noble Gas 65176 02/05/19 Weekly D-230 Noble Gas Instructions to Workers (IP Section 02.02)===
The inspectors evaluated instructions to workers including radiation work permits (RWPs)used to access high radiation areas:
Radiation work permits:
- RWP 19-1020: 64128865-0100 Remove In-core Thermocouples
- RWP 19-1070: 601109330-0000 RHR Weld Overlay Mobilization
- RWP 19-1004: 64146800-0100 Survey Letdown Line
- RWP 19-1006: 64135120-0020 Unit-1 Core Plate Vacuum Electronic alarming dosimeter alarms:
- DN 50975426: 04/10/18
- DN 50968587: 03/05/18
- DA 50968669: 03/05/18
- DN 50968145: 03/08/18
- DA 51017812: 02/19/19 Labeling of containers:
- No, 1060, Cl-36
- No. 1748, Cs-137
- No. 1750, Sr-90
- No. 1777, Cs-137
Contamination and Radioactive Material Control (IP Section 02.03) (1 Sample)
The inspectors evaluated licensee processes for monitoring and controlling contamination and radioactive material. The inspectors verified the following sealed sources are accounted for and are intact:
- No. 656, Cs-137
- No. 710, Cs-137
- No. 825, Cs-137
Radiological Hazards Control and Work Coverage (IP Section 02.04) (1 Sample)
The inspectors evaluated in-plant radiological conditions during facility walkdowns and observation of radiological work activities.
Radiological work permits for areas with airborne radioactivity:
- RWP 19-1020: 64128865-0100 Remove In-core Thermocouples
- RWP 19-1070: 601109330-0000 RHR Weld Overlay Mobilization
- RWP 19-1004: 64146800-0100 Survey Letdown Line
- RWP 19-1006: 64135120-0020 Unit-1 Core Plate Vacuum High Radiation Area and Very High Radiation Area Controls (IP Section 02.05) (1 Sample)
The inspectors evaluated risk-significant high radiation area and very high radiation area controls.
Radiation Worker Performance and Radiation Protection Technician Proficiency (IP Section 02.06) (1 Sample)
The inspectors evaluated radiation worker performance and radiation protection technician proficiency.
71124.03 - In-Plant Airborne Radioactivity Control and Mitigation
Engineering Controls (IP Section 02.01) (1 Sample)
The inspectors evaluated airborne controls and radioactive monitoring. The inspectors reviewed the following systems:
Installed ventilation systems
- Units 1 and 2, auxiliary building ventilation
- Units 1 and 2, control room ventilation
- Unit 2, fuel handling building ventilation Temporary ventilation system setups
- reactor head stand
- containment 91 foot inside bioshield 1-4
- pressurizer FCV-459 valve work
- reactor coolant pump 1-2 work Portable or installed monitoring systems
- containment AMS-4 (multiple) and portable grab samplers
- SPING #6 and associated back up AMS-4
- pressurizer FCV-459 valve work
Use of Respiratory Protection Devices (IP Section 02.02) (1 Sample)
The inspectors evaluated respiratory protection. The inspectors reviewed the following evaluations and tests:
Evaluations for the use of respiratory protection
- ALARA Plan 19-1026, "Unit 1 - 1R21 Lower Reactor Cavity Entries," Revision 0
- ALARA Plan 19-1061, "Unit1 - 1R21 Containment Valves and Breaches," Revision 0
- RWP 19-1020, "1R21 Reactor Disassembly and Reassembly," Revision 0, Respirator Use Evaluation
- RWP 19-1026, "1R21 Lower cavity and Transfer Canal Work, Lower Cavity Decontamination," Revision 0, Respirator Use Evaluation Respiratory protection use during work activities
- RWP 19-1020, "1R21 Reactor Disassembly and Reassembly," Revision 0
- RWP 19-1061, "1R21 Containment Valves and Breaches," Revision 0 Medical fitness for use of respiratory protection devices
- three contract radiation protection technicians providing work coverage
- three in-house radiation protection technicians providing work coverage
- three on-shift crew A, Unit 1 reactor operators
- two radiation protection supervisors Observation of donning, doffing and functional test
- three on-shift crew A Unit 1 reactor operators and two radiation protection technicians Respiratory protection device evaluation
- MaxAir: 082A, 174A, 183A, 186A
- Ultra Elite: UEL2004A, UEM0214A, UEM0244A, UES1057A
- Ultra Twin: UTL0382A, UTM0304A, UTM0452A, UTS0362A
Self-Contained Breathing Apparatus for Emergency Use (IP Section 02.03) (1 Sample)
The inspectors evaluated SCBA program implementation.
Status and surveillance records for SCBAs:
Second Stage Serial No.
First Stage Serial No.
EP-APA202352 EAB183440 EP-OAB274213 EAB183439 EP-OAB282747 EAB213170 EP-OAB301743 EAB246744
SCBA fit for on-shift operators
- Three on-shift crew A, Unit 1 reactor operators SCBA maintenance check:
Second Stage Serial No.
First Stage Serial No.
EP-APA202352 EAB183440 EP-OAB274213 EAB183439 EP-OAB282747 EAB213170 EP-OAB301743 EAB246744
OTHER ACTIVITIES - BASELINE
===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:
IE01: Unplanned Scrams per 7000 Critical Hours Sample (IP Section 02.01)===
- (1) Unit 1, date range: 01/01/2018-12/31/2018
- (2) Unit 2, date range: 01/01/2018-12/31/2018 IE03: Unplanned Power Changes per 7000 Critical Hours Sample (IP Section 02.02) (2 Samples)
- (1) Unit 1, date range: 01/01/2018-12/31/2018
- (2) Unit 2, date range: 01/01/2018-12/31/2018 IE04: Unplanned Scrams with Complications (USwC) Sample (IP Section 02.03) (2 Samples)
- (1) Unit 1, date range: 01/01/2018-12/31/2018
- (2) Unit 2, date range: 01/01/2018-12/31/2018
OR01: Occupational Exposure Control Effectiveness Sample (IP Section 02.15) (1 Sample)
- (1) date range: 01/01/2018 - 12/31/2018 PR01: Radiological Effluent Technical Specifications/Offsite Dose Calculation Manual Radiological Effluent Occurrences (RETS/ODCM) Radiological Effluent Occurrences
Sample. (IP Section 02.16) (1 Sample)
- (1) date range: 01/01/2018 - 12/31/2018
71152 - Problem Identification and Resolution
Annual Follow-up of Selected Issues (IP Section 02.03) (2 Samples)
The inspectors reviewed the licensees implementation of its corrective action program related to the following issues:
- (1) evaluation and corrective actions associated with trends in reactor coolant pump seal leakage on March 5, 2019
- (2) evaluation and corrective actions related to a Unit 1, polar crane main hoist overspeed trip during the reactor vessel head lift on March 9, 2019
71153 - Follow-up of Events and Notices of Enforcement Discretion Event Follow-up (IP Section 03.01)
The inspectors evaluated a sodium hydroxide leak from the Unit 2 containment spray system spray additive tank and the licensees response on March 4,
OTHER ACTIVITIES
- TEMPORARY INSTRUCTION, INFREQUENT, AND ABNORMAL Evaluation of Diablo Canyon Safety Condition in Light of Financial Conditions Because Pacific Gas & Electric Corporation, and its subsidiary, Pacific Gas & Electric Company (the licensee) was under bankruptcy protection/reorganization during the inspection period, NRC Region IV conducted special reviews of processes at Diablo Canyon. Using the flexibilities in the baseline inspection program, the inspectors evaluated several aspects of the licensees operations to determine whether the financial condition of the licensee impacted plant safety. The factors reviewed during this period included:
- (1) impact on staffing,
- (2) corrective maintenance backlog,
- (3) changes to the planned maintenance schedule,
- (4) corrective action program implementation, and
- (5) any reduction in outage scope, including risk-significant modifications. Considering the licensees financial difficulties, the inspectors verified that licensee personnel continued to identify problems at an appropriate threshold and enter these problems into the corrective action program for resolution. The inspectors also verified that the licensee continued to develop and implement corrective actions commensurate with the significance of the problems identified.
The special review of processes at Diablo Canyon included continuous reviews by the resident inspectors, as well as the specialist-led baseline inspections completed during the inspection period - emergency preparedness, inservice inspection, and radiation protection - which are documented in this report. During this period, the inspectors did not identify any indications that the licensees financial circumstances were adversely affecting plant performance and safety.
INSPECTION RESULTS
Failure to Promptly Correct an Adverse Condition Related to Reactor Coolant Pump Seal Damage Cornerstone Significance Cross-cutting Aspect Report Section Initiating Events
Green NCV 05000275/2019001-01 Closed
None 71152 The inspectors reviewed a Green, self-revealed non-cited violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, for the licensees failure to promptly identify and correct a condition adverse to quality. Specifically, prior to February 4, 2019, corrective actions generated as a result of a root cause evaluation did not adequately correct a condition adversely impacting reactor coolant pump (RCP) seals.
Description:
System interconnections between RCP seal drains, the pressurizer relief tank (PRT), and the radioactive drain collection tank (RCDT) comprise a closed system. RCP seal drains are hard piped to the RCDT and are designed to be free flowing. Evolutions such as draining the PRT into the RCDT can result in pressure imbalances which, if not properly controlled, can result in the backfilling of the RCP seal drains. This pressure imbalance can result in RCP seal instability and damage. Damage to the RCP seals can manifest itself through increased calculated RCS leakage.
In February 2013, prior to refueling outage 2R17, the 2-2 RCP seals were damaged and required replacement. As a result of this damage, PG&E performed a root cause evaluation and identified a root cause of backfilling of the RCP seals leading to seal damage. The root cause generated corrective actions that focused on correcting procedures that could lead to the backfill condition, as well as additional operator training on the RCDT/PRT system interconnections and draining procedures to prevent such damage from recurring.
On January 8, 2019, prior to the Unit 1 refueling outage 1R21, the inspectors noted increasing trends in reactor coolant system leakage and discussed with PG&E their actions to address this trend. PG&E initially believed that the observed changes to RCS leakage were due to leak rate calculational inaccuracies caused by the increasing frequency of dilutions required at end of core life. Additional review by PG&E prompted by a continued upward trend in identified RCS leakage rate determined the source of the RCS leakage to be from the 1-2 RCP #2 seal. Inspection of the 1-2 RCP seal package during the outage identified seal damage and resulted in the decision being made to replace the seal assembly.
PG&E subsequently determined that the draining of the PRT to the RCDT while carrying out the actions of alarm response procedure AR PK-05-25, Pressurizer Relief Tank (PRT)
Pressure/Level/Temperature, resulted in the backfilling of the system and damage to the seals. PG&E determined that revisions to this procedure should have been included as a corrective action from the 2013 root cause evaluation but were missed and not included.
Corrective Action(s): After the cause of the RCP seal leakage was identified, PG&E revised Annunciator Response Procedure AR PK-05-25, Pressurizer Relief Tank (PRT)
Pressure/Level/Temperature, to ensure proper control when draining the PRT to the RCDT during power operations and conducted additional operator training.
Corrective Action Reference(s): Notification 51014929
Performance Assessment:
Performance Deficiency: The inspectors determined that PG&Es failure to promptly identify and correct a degraded condition associated with the reactor coolant pumps seals during draining of the PRT to the RCDT was a performance deficiency within PG&Es ability to foresee and correct.
Screening: The performance deficiency was more than minor because it impacted the equipment performance attribute of the Initiating Events Cornerstone and its objective to limit the likelihood of events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Specifically, the licensees failure to ensure that appropriate corrective actions were taken in response to RCP seal damage caused by improper system operation in 2013 resulted in RCP seal damage to recur in 2019.
Significance: The inspectors assessed the significance of the finding using Appendix A, Significance Determination of Reactor Inspection Findings for At - Power Situations. The issue was evaluated in accordance with IMC 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, and determined to be of very low safety significance (Green) since it did not result in exceeding the RCS leak rate for a small break LOCA and did not affect systems used to mitigate a LOCA.
Cross-cutting Aspect: The inspectors did not identify a cross-cutting aspect associated with this finding because it did not reflect current performance.
Enforcement:
Violation: Title 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, requires, in part, that measures shall be established to assure that conditions adverse to quality are promptly identified and corrected. Contrary to the above, prior to February 4, 2019, the licensee failed to assure that a condition adverse to quality was promptly identified and corrected. Specifically, in conducting a root cause evaluation in 2013 on RCP seal vulnerability to damage when draining the PRT to the RCDT, the licensee failed to adequately identify and correct all pertinent operating procedures.
Enforcement Action: This violation is being treated as a non-cited violation, consistent with Section 2.3.2.a of the Enforcement Policy.
Inadequate Corrective Actions Leads to Increased Time at Yellow Risk and Lowered Inventory Cornerstone Significance Cross-cutting Aspect Report Section Initiating Events
Green FIN 05000275/2019001-02 Closed
[P.3] -
Resolution 71152 The inspectors reviewed a Green, self-revealed finding in that PG&E personnel failed to promptly correct a condition in accordance with OM7.ID1, Problem Identification and Resolution. Specifically, personnel did not promptly correct a condition associated with the Unit 1 polar crane variable frequency drive (VFD) motor used during the removal and replacement of the reactor vessel head from the reactor vessel during refueling outages that was first identified in 2015. This led to a recent event in which the reactor vessel head was suspended above the reactor vessel during a period of yellow outage safety risk with reactor vessel water level in lowered inventory condition for approximately 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> longer than necessary.
Description:
On March 8, 2019, the Diablo Canyon Power Plant, Unit 1, polar crane main hoist tripped during reactor head installation preventing the reactor vessel head from being raised or lowered. At the time of the trip, the reactor vessel head was suspended approximately 30 feet above the reactor vessel, reactor core, and upper internals. The station was in a yellow risk condition due, in part, to reactor vessel water level being in a lowered inventory condition. The reactor vessel head was in the credited heavy lift load path at all times, and all load drop safety devices on the polar crane functioned as designed.
After the polar crane main hoist trip, refueling outage day shift personnel commenced fact finding and troubleshooting activities. As a conservative measure, the containment equipment hatch was closed, and contingency preparations were made to flood up the refueling cavity. Approximately 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> later, shortly after turnover with day shift, outage nightshift subject matter experts recognized the fault was due to a VFD overspeed trip and promptly reset the condition, allowing the head to be lowered to its intended position.
Additional investigation by PG&E, including a review of the corrective action program database, revealed that the polar crane hoist mechanism for both units had suffered from similar VFD overspeed trip conditions on multiple occasions and that a work request had been generated in 2015 to replace a coupling device found in the VFD with a different type not susceptible to unnecessary overspeed trips. This work request was deleted from the scope of outage 1R19 and moved to 1R20. It was then deleted from the scope of 1R20 and moved to outage 1R21. During outage 1R21, the work was again deleted and deferred to a later outage. Additionally, no formal communication, operating experience, or procedure precautions or notes were generated as a result of the identified condition. These failures to promptly correct a condition associated with the polar crane VFD led to the reactor vessel head being unnecessarily suspended approximately 30 feet above the reactor vessel, core, and upper internals and the station remaining in a yellow risk condition with reactor vessel water level in a lowered inventory state for approximately 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> longer than required.
Corrective Action(s): After the event, PG&E performed an evaluation of the event, initiated changes to the applicable procedures, and scheduled work to upgrade the VFD such that similar events will not occur.
Corrective Action Reference: Notification 51017606
Performance Assessment:
Performance Deficiency: The inspectors determined that PG&Es failure to promptly correct a condition associated with the polar crane VFD motor used during the removal and replacement of the reactor vessel head from the reactor vessel during refueling outages was a performance deficiency within PG&Es ability to foresee and correct.
Screening: The performance deficiency was more than minor because it impacted the configuration control attribute of the Initiating Events cornerstone and its objective to limit the likelihood of events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Specifically, the failure to promptly correct a condition associated with the polar crane VFD led to an event in which the reactor vessel head was suspended above the reactor vessel during a period of yellow outage safety risk with reactor vessel water level in lowered inventory condition for approximately 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> longer than necessary.
Significance: The inspectors assessed the significance of the finding using Appendix G, Shutdown Safety SDP. Because the plant was shutdown with at least one fuel bundle in the reactor and temperature and pressure within normal decay heat removal conditions, the finding was evaluated in accordance with Attachment 1 of IMC 0609, Appendix G, Shutdown Operations Significance Determination Process, dated May 9, 2014. The finding was determined to be of very low safety significance (Green) since all questions in Attachment 1, Exhibit 2 were answered NO.
Cross-cutting Aspect: This finding is related to the cross-cutting area of Problem Identification and Resolution - Resolution because PG&E did not take effective corrective actions to address issues in a timely manner commensurate with its safety significance
[P.3]. Specifically, PG&Es failure to promptly correct a condition associated with the polar crane VFD led to the reactor vessel head being unnecessarily suspended approximately 30 feet above the reactor vessel, core, and upper internals and the station remaining in a yellow risk condition with reactor vessel water level in a lowered inventory state for approximately 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> longer than required.
Enforcement:
Inspectors did not identify a violation of regulatory requirements associated with this finding.
Human Performance Event Leads to Sodium Hydroxide Leak and Loss of Level Indication for Containment Spray System Spray Additive Tank Cornerstone Significance Cross-cutting Aspect Report Section Mitigating Systems
Green NCV 05000323/2019001-03 Closed
[H.12] - Avoid Complacency 71153 The inspectors reviewed a Green, self-revealed non-cited violation of Technical Specification 5.4.1.a Procedures, because personnel failed to follow the requirements of MP I-12-L931, Spray Additive Tank Level Channel 931 Calibration, Revision 2. Specifically, on March 4, 2019, during performance of a calibration of a Unit 2 containment spray additive tank level transmitter, PG&E technicians inadvertently removed a venting plug from the wrong level transmitter resulting in a pressurized leak of sodium hydroxide solution from the spray additive tank, and the inability to determine the level of the spray additive tank.
Description:
The containment spray system is a safety-related system designed to actuate in the event of certain accident scenarios to minimize peak pressure in containment and to reduce iodine fission product inventory in the containment atmosphere. The spray additive system is a subsystem of the containment spray system that provides a solution of sodium hydroxide to the containment spray pump discharge via a storage tank and an eductor. Two redundant level indicators, LI-931 and LI-932, are provided to ensure that the storage tank maintains the technical specification (TS) required level of sodium hydroxide solution, and so that actions can be taken during emergency operation prior to draining the spray additive tank to the point that the containment spray pumps become susceptible to air entrainment and binding.
On March 4, 2019, procedure MP I-12-L931, Spray Additive Tank Level Channel 931 Calibration, was being performed on LT-931, one of the two, Unit 2, containment spray system spray additive tank level indicators to ensure its proper functionality. This procedure is used to satisfy a TS surveillance requirement. During performance of this procedure, maintenance technicians inadvertently removed the venting plug from the in-service level indicator, LT-932, instead of the procedurally directed level indicator LT-931. This resulted in a pressurized stream of caustic sodium hydroxide solution coming from the vent plug for approximately 45 minutes and evacuation of the area until emergency response personnel were able to halt the leak. During this time, approximately 300 gallons of sodium hydroxide solution was released from the tank and the Unit 2 containment spray system was declared inoperable until operations personnel could verify that the spray additive tank levels were within TS required limits. The system remained inoperable for approximately 22 hours2.546296e-4 days <br />0.00611 hours <br />3.637566e-5 weeks <br />8.371e-6 months <br />. Later evaluation determined that the tank level never decreased below the TS required limit. Additionally, had they been called upon during an emergency event, emergency operating procedures for the containment spray system require that the spray additive tank be secured prior to reaching 16 percent level to ensure that the containment spray pumps do not become susceptible to damage from air entrainment and binding. During the approximately 22-hour period prior to restoration of level indication, operations personnel would not have been able to carry out this requirement due to a lack of valid spray additive tank level indication.
Corrective Action(s): After the leak was stopped and the caustic sodium hydroxide solution was removed from the area, PG&E personnel restored the level transmitter to service and verified that spray additive tank levels were within TS required limits. Additionally, PG&E initiated a cause evaluation and implemented corrective actions including a department level clock reset, station wide communication, and emphasis on the importance of the use of human performance tools prior to any work on station equipment.
Corrective Action Reference(s): Notification 51020536
Performance Assessment:
Performance Deficiency: The inspectors determined that PG&Es failure to follow procedure MP I-12-L931, Spray Additive Tank Level Channel 931 Calibration, Revision 2, was a performance deficiency within PG&Es ability to foresee and correct.
Screening: The performance deficiency was more than minor because it impacted the equipment performance attribute of the Mitigating Systems cornerstone and its objective to ensure the availability, reliability, and capability of systems that response to initiating events to prevent undesirable consequences. Specifically, the human performance event associated with the containment spray system spray additive tank level transmitter calibration resulted in a pressurized leak of sodium hydroxide solution from the spray additive tank, evacuation of the area, and the inability to detect spray additive tank level (as required by emergency procedures) for approximately 22 hours2.546296e-4 days <br />0.00611 hours <br />3.637566e-5 weeks <br />8.371e-6 months <br />.
Significance: The inspectors assessed the significance of the finding using Appendix A, Significance Determination of Reactor Inspection Findings for At - Power Situations. The issue was evaluated in accordance with IMC 0609, Appendix A, The Significance Determination Process for Findings At-Power, and determined to be of very low safety significance (Green) since the sodium hydroxide leak and inoperability of the Unit 2 containment spray system did not result in a loss of system function.
Cross-cutting Aspect: This finding is related to the cross-cutting area of Human Performance
- Avoid Complacency because PG&E did not recognize and plan for the possibility of mistakes, latent issues, and inherent risk, even while expecting successful outcomes. This included the implementation of appropriate error reduction tools [H.12]. Specifically, PG&E technicians failed to perform appropriate activity and work site reviews prior to performing work, use appropriate error reduction tools, or consider potential undesired consequences when conducting a level transmitter calibration procedure on the Unit 2 containment spray system.
Enforcement:
Violation: Technical Specification 5.4.1.a, Procedures, requires, in part, that maintenance that can affect the performance of safety-related equipment should be properly pre-planned and performed in accordance with written procedures, documented instructions, or drawings appropriate to the circumstances. Contrary to the above, on March 4, 2019, PG&E personnel failed to follow the requirements of procedure MP I-12-L931, Spray Additive Tank Level Channel 931 Calibration, Revision 2. Specifically, on March 4, 2019, during performance of a calibration of a Unit 2 containment spray additive tank level transmitter, PG&E technicians inadvertently removed a venting plug from the wrong level transmitter resulting in a pressurized leak of sodium hydroxide solution from the spray additive tank, evacuation of the area, and the inability to detect spray additive tank level.
Enforcement Action: This violation is being treated as a non-cited violation, consistent with Section 2.3.2.a of the Enforcement Policy.
EXIT MEETINGS AND DEBRIEFS
The inspectors verified no proprietary information was retained or documented in this report.
- On February 5, 2019, the inspectors presented the emergency preparedness inspection results to Mr. M. Ginn, Manager, Emergency Preparedness, and other members of the licensee staff.
- On February 26, 2019, the inspectors presented the inservice inspection results to Ms. P. Gerfen, Station Director, and other members of the licensee staff.
- On February 28, 2019, the inspectors presented the baseline radiation protection inspection results to Ms. P. Gerfen and other members of the licensee staff.
- On April 4, 2019, the inspectors presented the quarterly resident inspection results to Mr. J. Welsch, Vice President of Nuclear Generation and Chief Nuclear Officer, and other members of the licensee staff.
DOCUMENTS REVIEWED
71111.01: Adverse Weather Protection
Procedure
Number
Title
Revision
OP O-28
Operations Response to Storms or Biofouling
71111.04: Equipment Alignment
Notifications
51012721
51016118
Procedures
Number
Title
Revision
MP M-51.5
Testing and Maintenance of Safety/Relief Valves
OP A-2:X
RVRLIS Alignment for Refueling Outage
OP B-2:1
Residual Heat Removal Alignment Verification
OP B-2:V
RHR - Place in Service
OP B-2:VI
RHR - Draining the Refueling Cavity
OP B-2:VII
Residual Heat Removal System-Fill and Vent
OP J-6B:II-A
Diesel Generator 2-3 - Alignment Checklist
OP J-6B:III-A
Diesel Generator 2-2 - Alignment Checklist
Drawing
Number
Description
Revision
106710-2
RHR - System OVID
71111.05: Fire Protection
Notifications
50948204
50996387
51003929
Work Orders
60109333
64136730
Procedure
Number
Title
Revision
PEP 18-03
Containment Fire Water Jumper Installation and Removal
Drawings
Number
Description
Revision
PA1/2
Pre-Fire Plans Intake Structure
PA26/27
Pre-Fire Plans Containment Building 91 and 117, Unit 1
Containment Building Elevation 140, Unit 1
RA-7
Radiological Control Area & H Block Elev. 100, Unit 2
Other
Number
Description
Date
Hot Work Permit 1769
03/09/2019
71111.07: Heat Sink Performance
Notifications
51021896
51018644
51022042
Work Orders
220069
220070
Procedures
Number
Title
Revision
OP F-2
CCW System
8A
OP F-2: I
CCW Make Available
Drawings
Number
Description
Revision
106714
CCW System
663212
CCW Mechanical Heat Exchanger Tube Plugging Map,
Sheet 1
Other
Number
Description
Date
27985
Component Cooling Water Heat Exchangers CCW 1-1 and
1-2 Eddy Current Report
2/2019
71111.08: Inservice Inspection Activities (PWR)
Notifications
50315950
50914808
50915722
50915871
50920366
50920367
50920368
50920369
50921421
50925730
50927788
50928799
50956677
50956730
50998093
50988345
51004997
51008168
51017806
Work Orders
64025645
60105066
68052869
60100625
60100791
60094591
64132540
60101082
Procedures
Number
Title
Revision
AD4.ID2
Plant Leakage Evaluation
AD7.ID11
Fluid Leak Management Program
ER1.ID2
Boric Acid Corrosion Control Program
ISI P-SI-18
SIS Test System Piping Pressurization for ISI Inspection
Reactor Vessel Top and Bottom Head Visual Inspections
ISI_P-AFW-13U1 ISI Pressure Test of AFW Suction Supply Piping Aligned to
the Raw Water Storage Reservoir Using a Hydro Pump
Visual Examination During Section XI System Pressure Test 4
NDE_PDI-UT-2
Ultrasonic Examination of Austenitic Piping
NDE_PT-1
Visible Dye Liquid Penetrant Examination Procedure
NDE_UT-4
Ultrasonic Examination of Pressure Vessel Welds Other
than Reactor Vessels
NDE_UT-I
Ultrasonic Detection and Sizing of Vessel Nozzle Inside
Radius
NDE_VT_1-1
Visual Examination of Component Surfaces
Procedures
Number
Title
Revision
NDE_VT_2-1
Visual Examination During Section XI System Pressure Test 4
NDE_VT_3-1
Visual Examination of Component and Piping Supports
OM8.ID4
Control of Flammable and Combustible Materials
PD MA3
Special Processes
STP M-86
Leak Reduction of Systems Outside Containment Likely to
Contain Radioactive Materials following an Accident
STP M-87
Operational Leakage of ECCS Recirc Paths Outside
Containment
STP R 8C
Containment Walkdown for Evidence of Boric Acid Leakage 10
Drawing
Number
Description
Revision
663056
Auxiliary Feedwater Terry Turbine Pump
71111.11: Licensed Operator Requalification Program and Licensed Operator
Performance
Notification
51016118
Procedures
Number
Title
Revision
EOP E-0
Reactor Trip or Safety Injection
45B
JSIM-507
Evaluator Skills
OP B-2:V
RHR-Place in Service
OP L-4
Normal Operations at Power
OP L-5
Plant Cooldown from Minimum Load to Cold Shutdown
105
OP L-5
Plant Cooldown From Minimum Load to Cold Shutdown
105A
OP L-7
Plant Stabilization Following Reactor Trip
25A
TQ2.DC3
Licensed Operator Continuing Training Program
71111.12: Maintenance Effectiveness
Notifications
51012969
51021080
50605355
288884
50636744
51017754
Other
Number
Description
Revision /
Date
DCN 24558
Damper Modifications 4 kV Rooms
11/28/2018
PC-23E1-01
Maintenance Rule Impacted Function
71111.13: Maintenance Risk Assessments and Emergent Work Control
Procedures
Number
Title
Revision
AD7.DC6
On-Line Maintenance Risk Management
OP A-2:X
RVRLIS Alignment for Refueling Outages
OP O-36
Protected Equipment Postings
Other
Number
Description
Revision
1R21 Outage Safety Plan
71111.15: Operability Determinations and Functionality Assessments
Notifications
51011651
51011752
51011572
51010580
51016998
51016118
51016269
51022188
51022414
51020413
51020574
51020501
Work Orders
60116677
60117408
Procedures
Number
Title
Revision
OM7.ID12
Procedures
Number
Title
Revision
STP I-1B
Routine Daily Checks Required by Licenses
29
STP R-10C
Reactor Coolant System Water Inventory Balance
Drawing
Number
Description
Revision
106710
Residual Heat Removal, Sheet 2
Other
Number
Description
Date
Unit 1 Containment Pressure Trend Data
01/2019
Unit 1 Containment Temperature Trend Data
01/2019
Unit 1 Radiation Monitor RM-11 (Containment Air
Particulate) Trend Data
01/2019
Unit 1 Radiation Monitor RM-12 (Containment Radiological
Gas) Trend Data
01/2019
Unit 1 RCS Leak Rate Calculation Packages per STP I-1B
01/20/2019 -
01/30/2019
Unit 1 RCS Leak Rate Calculation Packages per STP R-
10C
01/20/2019 -
01/30/2019
Unit 1 Reactor Coolant Pump 1-1, 1-2, 1-3, and 1-4 Seal
No. 1 Leakoff Trend Data
01/2019
Unit 1 Reactor Coolant Pump 1-1, 1-2, 1-3, and 1-4 Seal
Water Inlet Trend Data
01/2019
51011572
Emerging Issue - Elevated Unit 1 RCS Calculated Leak
Rates
01/15/2019,
01/29/2019,
01/31/2019
71111.18: Plant Modifications
Notifications
50986428
51015255
51015257
51015176
51015256
51011572
Procedures
Number
Title
Revision
CF3.ID9
Design Change Notice
MP M-21.8
Diesel Engine Governor Actuator Maintenance
TS3.ID2
Licensing Basis Impact Evaluations
44A
Other
Number
Description
Revision
DCP 25262
EDG Governor Controls Upgrade
71111.19: Post-Maintenance Testing
Notifications
51023045
51022989
51018293
51017982
51018598
51019542
51023045
51022989
Work Orders
64159084
64158929
60116970
60116968
64123070
60117148
60102262
64157306
Procedures
Number
Title
Revision
MP E-50.1
Thermal Overload Relay and Cubicle Maintenance
MP E-57.10C
kV Motor Preventative Maintenance Testing
MP E-67.3C
Maintenance of Solidstate Controls 400A Vital Station
Battery Chargers
STP M-12B
Battery Charger Performance Test
STP M-83A
Penetration Overcurrent Protection
29A
STP P-ASW-11
Routine Surveillance Test of Turbine-Driven Auxiliary
Feedwater pump 1-1
STP P-CCP-23
Routine Surveillance Test of Centrifugal Charging Pump 2-3 8
71111.20: Refueling and Other Outage Activities
Notifications
51018584
51018358
51019722
51016530
51019158
51017079
51014929
51016562
51019171
51011572
51016362
51016543
51015960
51017642
51023590
51018335
51016804
51016680
51016126
Procedures
Number
Title
Revision
AD8.DC51
Outage Safety Management Control of Off-Site Power
Supplies to Vital Buses
AD8.DC54
Containment Closure
AD8.DC55
Outage Safety Scheduling
EOP E-0
Reactor Trip of Safety Injection
45B
ER1.ID2
Boric Acid Corrosion Control Program
ISI X-2
Visual Inspection of Reactor Upper Internals
MP I-2.28
Activation and Deactivation of the Rx Vsl Refueling Lvl
Indication System (RVRLIS)
28A
MP M-45.1
Containment Equipment Hatch Door Opening and Closing
MP M-7.6A
Reactor Vessel Upper Internals Removal
OM14.ID1
Fatigue Management Rule Program
OM14.ID1
Fatigue Management Rule Program
OP A-2:II
Reactor Vessel - Draining the RCS to the Vessel Flange -
With Fuel in Vessel
OP A-2:IX
Reactor Vessel - Vacuum Refill of the RCS
OP A-2:X
RVRLIS Alignments for Refueling Outages
OP B-1A:VIII
Makeup Control System Operation
OP B-2:V
RHR - Place in Service
OP B-2:VI
RHR-Draining the Refueling Cavity
OP B-8DS2
Core Loading
Procedures
Number
Title
Revision
OP L-0
Mode Transition Checklists
OP L-2
Hot Standby to Startup Mode
OP L-4
Normal Operation at Power
OP L-5
Plant Cooldown From Minimum Load to Cold Shutdown
105A
OP L-7
Plant Stabilization Following Reactor Trip
25A
OP2.ID1
Clearances
STP M-45A
Containment Inspection Prior to Establishing Containment
Integrity
34A
STP R-30
Reload Cycle Initial Criticality
19A
STP R-6
Low Power Reload Physics Tests
STP R-8C
Containment Walk down for Evidence of Boric Acid Leakage 10
Other
Number
Description
Revision /
Date
57725
Containment Equipment Drawing 91&100 foot
1R21 Outage Safety Plan
Calculation
PRA19-02
Mode Transition With CFCUs 1-4 and 1-4 Unavailable
DCPP Form 69-
21350
Fatigue Management Rule Waiver Attachment 3
2/12/2019
EmpCenter Time
Entry
Hours Entry Data Sheets
2/18/2019
Security Door
History
Door Reader Transactions
2/10/2019
71111.22: Surveillance Testing
Notifications
51016229
51016422
51016489
51016141
51910387
51011572
50910387
51010580
51012111
51012113
51012096
51022989
51023045
51023787
Work Orders
222140
64033435
64194016
64136202
201622
64136401
Procedures
Number
Title
Revision
ER1.ID2
Boric Acid Corrosion Control Program
STP I-1B
Routine Daily Checks Required By Licenses
29
STP I-9
kV Bus RCP U/F and U/V Channels Calibration and Time
Response Test
STP M-15
Integrated Test of Engineered Safeguards and Diesel
Generators
STP M-7
Integrated Leak Rate Test (ILRT) Type A
STP M-7E
Containment Penetration Valve Lineup for the Integrated
Leakage Rate Test (ILRT)
STP M-7W
Containment Structural Integrity Inspection
STP P-AFW-
PS11
Preservice Testing of Turbine-Driven Auxiliary Feedwater
Pump 1-1
STP R-10
Reactor Coolant System Leakage Evaluation
STP R-10C
Reactor Coolant System Water Balance Inventory
STP V-5A1
Emergency Core Cooling System Check Valve Leak Test,
Post-Refueling/Post-Maintenance Valves 8819 A-D and
8956 A-D
STP V-600
General Containment Isolation Valve Leak Test
STP V-654B
Penetration 52B Containment Isolation Valve Leak Testing
Drawing
Number
Description
Revision
106709
Safety Injection, Sheet 2
Other
Number
Description
Revision
ANSI/ANS-56.8-
2002Property "ANSI code" (as page type) with input value "ANSI/ANS-56.8-</br></br>2002" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process.
Containment System Leakage Testing Requirements
71114.04: Emergency Action Level and Emergency Plan Changes
Miscellaneous Documents
Number
Title
Date
PG&E Letter
Diablo Canyon Units 1 and 2; Docket No. 50-275, OL-DPR-
80; Docket No. 50-323, OL-DPR-82; License Amendment
Request 16-04; Request to Adopt Emergency Action Level
Schemes Pursuant to NEI 99-01, Revision 6, Development
of Emergency Action Levels for Non-Passive Reactors
10/25/2016
PG&E Letter
Docket No. 50-275, OL-DPR-80; Docket No. 50-323, OL-
DPR-82; Diablo Canyon Units 1 and 2; Response to NRC
Request for Additional Information Regarding License
Amendment Request 16-04, Request to Adopt Emergency
Action Level Schemes Pursuant to NEI 99-01, Revision 6,
Development of Emergency Action Levels for Non-Passive
Reactors
06/21/2017
PG&E Letter
Diablo Canyon Units 1 and 2; Docket No. 50-275, OL-DPR-
80; Docket No. 50-323, OL-DPR-82; Supplement to
License Amendment Request 16-04; Request to Adopt
Emergency Action Level Schemes Pursuant to NEI 99-01,
Revision 6, Development of Emergency Action Levels for
Non-Passive Reactors
08/17/2017
PG&E Letter
PG&E Letter
DIL-18-013
Docket No. 50-275, OL-DPR-80; Docket No. 50-323, OL-
DPR-82; Diablo Canyon Units 1 and 2; Docket No 72026,
Materials License No. SNM-2511; Diablo Canyon
Independent Spent Fuel Storage Installation; Emergency
Plan Implementing Procedure Update
10/04/2018
71124.01: Radiological Hazard Assessment and Exposure Controls
Notifications
51012602
51012603
51012604
51017804
50975426
50968020
50968587
50969660
50989145
51019595
Procedures
Number
Title
Revision
RCP NISP-RP.05 Access Controls for High Radiation Areas
RCP NISP-RP.02 Radiation & Contamination Surveys
RCP D-335
Radiation Exposure Reporting
RCP D-620
Radioactive Source Control Program
Procedures
Number
Title
Revision
RCP NISP-RP.04 Radiological Posting & Labelling
RP1-1D17
Control & Storage of Non-SNM
RP1-1D16
Radiation Work Expectations
RP1-1D9
Radiation Work Permits
RP1-1D14
Radioactive Material Controls
RP1-1D15
Radiological Risk Assessment
Audits and Assessments
Number
Description
Date
173180001
2018 Radiation Protection Programs Audit
2/25/2018
QV 180850014
Quality Verification 2R20 Integrated Outage Assessment
04/17/2018
Notification
51012084
NRC Pre-Inspection on Radiological Hazard Assessment
and Exposure Controls 71124.01
01/14/2019
Radiation Work Permits
Number
Description
Revision
RWP 19-1004
WO 64146800-0100 Survey Letdown Line
RWP 19-1006
WO 64135120-0020 Unit-1 Core Plate Vacuum
RWP 19-1020
WO 64128865-0100 Remove In-core Thermocouples
RWP 19-1050:
WO 641358461-0100 Inspect RCS Flange for RCS
Leakage
RWP 19-1070
WO 601109330-0000 RHR Weld Overlay Mobilization
Radiological Surveys
Number
Description
Date
65894
Containment
2/24/2019
65937
Containment
2/25/2019
66011
2/26/2019
66023
Containment
2/26/2019
66031
Containment
2/26/2019
66787
Containment
2/22/2019
Number
Description
Date
61738
Air Sample: 17-F-001 Filter Liner Solidification Preps
05/02/2018
64476
Air Sample: Particulate Air Sample Filter storage in Vault 3
2/10/2018
65063
Air Sample: D-230 Noble Gas
01/29/2019
65536
Air Sample: D-230 Noble Gas
2/05/2019
Miscellaneous Documents
Number
Description
Date
Ready for Issue High, Locked High, and Very High
Radiation Area Key Inventory
2/26/2019
GPAA102
DCPP General Employee Training
06/30/2016
NSTS Annual Inventory Reconciliation Form
01/08/2019
RPS17J
DCPP Radiological Self-Monitoring
03/18/2014
Semi-annual Sealed Source Inventory/Leak Test
2/05/2019
Semi-Annual Sealed Source Inventory/Leak Test
08/18/2018
71124.03: In-Plant Airborne Radioactivity Control and Mitigation
Notifications
50930710
50931849
50934622
50944439
50946792
50947936
50950636
50954291
50960981
50961668
50965343
50966263
50975820
50976449
50978069
50999314
51012085
51013771
Procedures
Number
Title
Revision
OM6.ID10
Respiratory Protection Program
PEP M-92
Post LOCA Sampling Center Ventilation Systems DOP and
HALIDE Penetration Tests
RCP D-410
Issuing Respiratory Protective Equipment
RCP D-645
HEPA Integrity Testing
RCP D-700
Processing Respiratory Protection Equipment at DCPP
RCP D-707A
MSA FireHawk (NIOSH) Self-Contained Breathing
1A
Procedures
Number
Title
Revision
Apparatus Inspection
RCP D-709
Posi-Chek3 Tester Operation
RCP D-712
MAXAIR Powered Air Purifying Respirator
RCP D-732
Respirator Fit Testing
RCP D-772
UNICUSIII Cylinder Recharging Station Operation
RCP NISP-RP.03 Radiological Air Sampling
RCP NISP-RP.08 Use and Control HEPA Filtration and Vacuum Equipment
STP M-53
Control Room Ventilation System DOP and Halide
Penetration Tests
21A
STP M-6A
Routine Surveillance Testing of Control Room Ventilation
System
TQ1.DC20
Respirator Training
Audits and Self-Assessments
Number
Description
Date
DS-16-008
NUPIC Commercial Grade Survey - F&J Specialty Products 08/02/2016
229
NUPIC Audit -GEL Laboratories, LLC
11/03/2016
24351
NUPIC Audit - Mirion Technologies (Canberra), Inc.
11/06/2017
24371
NUPIC Audit - Reuter-Stokes LLC
2/21/2017
ASMP SAQH
51012085
Quick Hit Self-Assessment (QHSA) - NRC Inspection
01/29/2019
Respirator Testing, Inspection, and Inventory Records
Number
Description
Date
Weekly Respirator Locker Inventory
01/14/2019
EP-APA202352
Complete SCBA Test
01/09/2019
EP-APA202352
Monthly and Annual Inspection and Maintenance Checklist
2017-2018
EP-OAB274213
Complete SCBA Test
2/01/2018
EP-OAB274213
Complete SCBA Test
2/02/2017
EP-OAB274213
Monthly and Annual Inspection and Maintenance Checklist
2017-2018
Respirator Testing, Inspection, and Inventory Records
Number
Description
Date
EP-OAB282747
Monthly and Annual Inspection and Maintenance Checklist
2017-2018
EP-OAB301743
Complete SCBA Test
2/22/2017
EP-OAB301743
Monthly and Annual Inspection and Maintenance Checklist
2017-2018
Engineered System Filter Test Records
Number
Description
Date
60076341-5000
STP G-11, Procedure for Obtaining Charcoal Filer Media
for laboratory Testing (Methyl Iodine): Fuel Handling
Building Ventilation System, Revision 20 [old charcoal]
01/14/2019
60076341-5010
STP G-11, Procedure for Obtaining Charcoal Filer Media
for laboratory Testing (Methyl Iodine): Fuel Handling
Building Ventilation System, Revision 20 [new charcoal]
01/14/2019
60078958-5000
STP G-11, Procedure for Obtaining Charcoal Filer Media
for laboratory Testing (Methyl Iodine): Control Room
Ventilation System, Revision 20
04/25/2017
64114011-0100
STP M-53, Unit 2 Control Room Ventilation System DOP
and Halide Penetration Tests, Revision 13
04/19/2017
64114015-0200
STP G-9, Unit 2 General HEPA Filter Bank Penetration
Test: Control Room Ventilation System, Revision 9; and
STP G-10, Unit 1 General Charcoal Filter Bank Penetration
Test: Control Room Ventilation System, Revision 8
04/25/2017
64156652-0100
STP G-9, Unit 1 General HEPA Filter Bank Penetration
Test: Fuel Handling Building Ventilation System, Revision 9
[old charcoal]
01/14/2019
64156652-0200
STP G-9, Unit 1 General HEPA Filter Bank Penetration
Test: Fuel Handling Building Ventilation System, Revision 9
[new charcoal]
01/14/2019
64156654-0100
STP G-10, Unit 1 General Charcoal Filter Bank Penetration
Test: Fuel Handling Building Ventilation System, Revision 8
[old charcoal]
01/14/2019
64156654-0200
STP G-10, Unit 1 General Charcoal Filter Bank Penetration
Test: Fuel Handling Building Ventilation System, Revision 8
[new charcoal]
01/14/2019
64156655-0100
STP M-41, Unit 1 Fuel Handling Building Ventilation
System DOP and Halide Penetration Tests, Revision 20
[old charcoal]
01/14/2019
Engineered System Filter Test Records
Number
Description
Date
64156655-0300
STP M-41, Unit 1 Fuel Handling Building Ventilation
System DOP and Halide Penetration Tests, Revision 20
[new charcoal]
01/14/2019
64171179-0010
STP M-3A, Unit 1 DOP and Halide Penetration Test:
Auxiliary Building Ventilation System, Revision 23
2/06/2019
64171179-0040
STP G-9, Unit 1 General HEPA Filter Bank Penetration
Test: Auxiliary Building Ventilation System, Revision 9; STP
G-10, Unit 1 General Charcoal Filter Bank Penetration Test:
Auxiliary Building Ventilation System, Revision 8; and STP
G-11, Procedure for Obtaining Charcoal Filer Media for
laboratory Testing (Methyl Iodine): Auxiliary Building
Ventilation System, Revision 20
2/21/2019
Compressed Air System Testing Records
Number
Description
Date
Annual UNICUS Internal High-Pressure Storage Cylinders
Maintenance and Testing (DCPP Form 69-21535): ACPP1
2018 - 2019
Annual UNICUS Internal High-Pressure Storage Cylinders
Maintenance and Testing (DCPP Form 69-21535): ACPP2
2018 - 2019
Quarterly ACPP1 BAC 0-1 Trace Analytics CGA G-71.
Grade L (SCBA) Air Quality Check
03/13/2017 -
2/18/2019
Quarterly ACPP2 BAC 0-2 Trace Analytics CGA G-71.
Grade L (SCBA) Air Quality Check
03/13/2017 -
11/27/2018
Miscellaneous Documents
Number
Description
Revision /
Date
ALARA Plan 19-1026, "Unit 1, 1R21 Lower Reactor Cavity
Entries"
01/29/2019
ALARA Plan 19-1061, "Unit1, 1R21 Containment Valves
and Breaches
2/01/19
ALARA Plan 19-1071, Unit 1, 1R21 RHR Weld Overlay
01/16/2019
Respiratory Use Training, Fit Testing, and Medical
Evaluation for Selected Staff
01/01/2017 -
2/25/2019
RWP 19-1020, Unit 1, 1R21 Reactor Disassembly and
Reassembly Respirator Use Evaluation
01/31/2019
Miscellaneous Documents
Number
Description
Revision /
Date
RWP 19-1026, Unit 1, 1R21 Lower Cavity and Transfer
Canal Work, Lower Cavity Decontamination Respirator
Use Evaluation
01/31/2019
RWP 19-1061, "Unit 1, 1R21 Containment Valves and
Breaches
71151: Performance Indicator Verification
Procedures
Number
Title
Revision
AWP L-001
NRC Performance Indicators Initiating Events, SSFFs, and
Regulatory Assessment Performance Indicator Guideline
XI1.ID2
Regulatory Reporting Requirements
XI1.ID5
Collection and Submittal of NRC Performance Indicators
71152: Problem Identification and Resolution
Notifications
51014929
50538422
51014888
51023735
51013122
51011572
51012537
51018347
51018600
51022176
268718
50403406
50544835
50663799
51017693
50351332
50535340
50662412
50815303
51017606
Procedures
Number
Title
Revision
AR PK05-25
Annunciator Response PRT PRESS/LVL TEMP
OM4.ID14
Notification Review Team (NRT)
OM7.ID1
Problem Identification and Resolution
OP1.DC40
Operations Equipment Deficiency and Adverse Condition
Monitoring
PAPERWORK REDUCTION ACT STATEMENT
This letter does not contain new or amended information collection requirements subject to the
Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection
requirements were approved by the Office of Management and Budget, Control
Number 31500011. The NRC may not conduct or sponsor, and a person is not required to
respond to, a request for information or an information collection requirement unless the
requesting document displays a currently valid Office of Management and Budget control
number.
This letter and its enclosure will be made available for public inspection and copying at
http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in
accordance with 10 CFR 2.390, Public Inspections, Exemptions, and Requests for
Withholding.
Information Request
December 12, 2018
Notification of Inspection and Request for Information
Diablo Canyon Unit 1
NRC Inspection Report 05000275/2019001
INSERVICE INSPECTION DOCUMENT REQUEST
Inspection Dates: February 11 - 22, 2019
Inspector: Jim Drake
A. Information Requested for the In-Office Preparation Week
The following information should be sent to the Region IV office in hard copy or electronic
format or via a secure document management service, in care of Jim Drake, by January 22,
2019, to facilitate the selection of specific items that will be reviewed during the onsite
inspection week. The inspector will select specific items from the information requested
below and then request from your staff additional documents needed during the onsite
inspection week (Section B of this enclosure). We ask that the specific items selected from
the lists be available and ready for review on the first day of inspection. Please provide
requested documentation electronically if possible. If requested documents are large and
only hard copy formats are available, please inform the inspector(s), and provide subject
documentation during the first day of the onsite inspection.
If you have any questions regarding this information request, please call the inspector as
soon as possible.
On February 11, 2019, a reactor inspector from the Region IV office will perform the
baseline inservice inspection at Diablo Canyon Unit 1, using NRC Inspection
Procedure 71111.08, "Inservice Inspection Activities. Experience has shown that this
inspection is a resource intensive inspection both for the NRC inspector and your staff. The
date of this inspection may change dependent on the outage schedule you provide. In order
to minimize the impact to your onsite resources and to ensure a productive inspection, we
have enclosed a request for documents needed for this inspection. The information
identified on this request (Section A) is to be provided prior to the inspection to ensure that
the inspector(s) are adequately prepared. The section identified as Documents Upon
Request is intended to provide guidance to the type of information an inspector(s) will be
requesting to complete the inspection. It is important that all of these documents are up to
date and complete in order to minimize the number of additional documents requested
during the preparation and/or the onsite portions of the inspection (i.e., condition reports with
attachments).
We have discussed the schedule for these inspection activities with your staff and
understand that our regulatory contact for this inspection will be David Madsen of your
licensing organization. The tentative inspection schedule is as follows:
Preparation week: January 28 to February 1, 2019
Onsite weeks: February 11 - 22, 2019
Our inspection dates are subject to change based on your updated schedule of outage
activities. If there are any questions about this inspection or the material requested, please
contact Jim Drake at (817) 200-1558. (email to: James.Drake@nrc.gov)
A.1
ISI/Welding Programs and Schedule Information
1. A detailed schedule (including preliminary dates) of:
1.1. Nondestructive examinations planned for ASME Code Class Components
performed as part of your ASME Section XI, risk informed (if applicable), and
augmented inservice inspection programs during the upcoming outage.
1.2. Examinations planned for Alloy 82/182/600 components that are not included in
the Section XI scope (If applicable)
1.3. Examinations planned as part of your boric acid corrosion control program
(Mode 3 walkdowns, bolted connection walkdowns, etc.)
1.4. Welding activities that are scheduled to be completed during the upcoming
outage (ASME Class 1, 2, or 3 structures, systems, or components)
2. A copy of ASME Section XI Code Relief Requests and associated NRC safety
evaluations applicable to the examinations identified above.
2.1. A list of ASME Code Cases currently being used to include the system and/or
component the Code Case is being applied to.
3. A list of nondestructive examination reports which have identified recordable or
rejectable indications on any ASME Code Class components since the beginning of
the last refueling outage. This should include the previousSection XI pressure test(s)
conducted during start up and any evaluations associated with the results of the
pressure tests.
4. A list including a brief description (e.g., system, code class, weld category,
nondestructive examination performed) associated with the repair/replacement
activities of any ASME Code Class component since the beginning of the last outage
and/or planned this refueling outage.
5. If reactor vessel weld examinations required by the ASME Code are scheduled to
occur during the upcoming outage, provide a detailed description of the welds to be
examined and the extent of the planned examination. Please also provide reference
numbers for applicable procedures that will be used to conduct these examinations.
6. Copy of any 10 CFR Part 21 reports applicable to structures, systems, or
components within the scope of Section XI of the ASME Code that have been
identified since the beginning of the last refueling outage.
7. A list of any temporary non-code repairs in service (e.g., pinhole leaks).
8. Please provide copies of the most recent self-assessments for the inservice
inspection, welding, and Alloy 600 programs.
9. A copy of (or ready access to) most current revision of the inservice inspection
program manual and plan for the current interval.
10. Copy of NDE procedures for NDE that will be used during the outage.
11. Copy of overarching site procedure for welding.
A.2
1. Provide a detailed scope of the planned bare metal visual examinations (e.g., volume
coverage, limitations, etc.) of the vessel upper head penetrations and/or any
nonvisual nondestructive examination of the reactor vessel head including the
examination procedures to be used.
1.1. Provide the records recording the extent of inspection for each penetration
nozzle including documents which resolved interference or masking issues
that confirm that the extent of examination meets 10 CFR 50.55a(g)(6)(ii)(D).
1.2. Provide records that demonstrate that a volumetric or surface leakage path
examination assessment was performed.
2. Copy of current calculations for EDY, and RIY as defined in Code Case N-729-1 that
establish the volumetric and visual inspection frequency for the reactor vessel head
and J-groove welds.
A.3
Boric Acid Corrosion Control Program
1. Copy of the procedures that govern the scope, equipment and implementation of the
inspections required to identify boric acid leakage and the procedures for boric acid
leakage/corrosion evaluation.
2. Please provide a list of leaks (including code class of the components) that have
been identified since the last refueling outage and associated corrective action
documentation. If during the last cycle, the unit was shutdown, please provide
documentation of containment walkdown inspections performed as part of the boric
acid corrosion control program.
A.4
Additional Information Related to all Inservice Inspection Activities
1. A list with a brief description of inservice inspection, and boric acid corrosion control
program related issues (e.g., PVAR) entered into your corrective action program
since the beginning of the last refueling outage. For example, a list based upon data
base searches using key words related to piping such as: inservice inspection,
ASME Code,Section XI, NDE, cracks, wear, thinning, leakage, rust, corrosion, boric
acid, or errors in piping examinations.
2. Provide training (e.g. Scaffolding, Fall Protection, FME, Confined Space) if they are
required for the activities described in A.1 through A.3.
3. Please provide names and phone numbers for the following program leads:
Inservice inspection (examination, planning)
Containment exams
Reactor pressure vessel head exams
Snubbers and supports
Repair and replacement program
Licensing
Site welding engineer
Boric acid corrosion control program
DOCUMENTS UPON REQUEST
Inservice Inspection / Welding Programs and Schedule Information
1. Updated schedules for inservice inspection/nondestructive examination activities,
including planned welding activities, and schedule showing contingency repair plans, if
available.
2. For ASME Code Class welds selected by the inspector please provide copies of the
following documentation (as applicable) for each subject weld:
Weld data sheet (traveler).
Weld configuration and system location.
Applicable welding procedures used to fabricate the welds.
Copies of procedure qualification records (PQRs).
Welders performance qualification records (WPQ).
Nonconformance reports for the selected welds (If applicable).
Radiographs of the selected welds and access to equipment to allow
viewing radiographs (if radiographic testing was performed).
Preservice and inservice examination records for the selected welds.
- Readily accessible copies of nondestructive examination personnel
qualifications records for reviewing.
3. For ultrasonic examination procedures qualified in accordance with ASME Code,
Section XI, Appendix VIII, provide documentation supporting the procedure
qualification (e.g. the EPRI performance demonstration qualification summary sheets).
Also, include qualification documentation of the specific equipment to be used (e.g.,
ultrasonic unit, cables, and transducers including serial numbers) and nondestructive
examination personnel qualification records.
1. Nondestructive personnel qualification records for the examiners who will perform
examinations of the reactor pressure vessel head replacement. (If applicable)
2. Drawings showing the following:
Reactor pressure vessel head and control rod drive mechanism nozzle
configurations
Reactor pressure vessel head insulation configuration
Note: The drawings listed above should include fabrication drawings for the nozzle
attachment welds as applicable.
Boric Acid Corrosion Control Program
1. Boric acid walk down inspection results, an updated list of boric acid leaks identified
so far this outage, associated corrective action documentation, and overall status of
planned boric acid inspections.
2. List of boric acid evaluation and corrective action documents associated with the
leakage.
Codes and Standards
1. Ready access to (i.e., copies provided to the inspector(s) for use during the
inspection at the onsite inspection location, or room number and location where
available):
Applicable Editions of the ASME Code (Sections V, IX, and XI) for the
inservice inspection program and the repair/replacement program.
2. Copy of the performance demonstration initiative (PDI) generic procedures with the
latest applicable revisions that support site qualified ultrasonic examinations of piping
welds and components (e.g., PDI-UT-1, PDI-UT-2, PDI-UT-3, PDI-UT-10, etc.).
3. Boric Acid Corrosion Guidebook Revision 1 - EPRI Technical Report 1000975.
The following items are requested for the
Occupational Radiation Safety Inspection
Diablo Canyon
Inspection Dates February 25 - March 1, 2019
Integrated Report 2019001
Inspection areas are listed in the attachments below.
Please provide the requested information on or before February 15, 2019
Please submit this information using the same lettering system as below. For example, all
contacts and phone numbers for Inspection Procedure 71124.01 should be in a file/folder titled
1-A, applicable organization charts in file/folder 1-B, etc.
If information is placed on your normal data management system, please ensure the inspection
exit date entered is at least 45 days later than the onsite inspection dates, so the inspectors will
have access to the information while writing the report.
In addition to the corrective action document lists provided for each inspection procedure listed
below, please provide updated lists of corrective action documents at the entrance meeting.
The dates for these lists should range from the end dates of the original lists to the day of the
entrance meeting.
If more than one inspection procedure is to be conducted and the information requests appear
to be redundant, there is no need to provide duplicate copies. Enter a note explaining in which
file the information can be found.
If you have any questions or comments, please contact Louis Carson at (817)200-1221,
Louis.Carson@nrc.gov or John ODonnell at (817)200-1441, John.ODonnell@nrc.gov
PAPERWORK REDUCTION ACT STATEMENT
This letter does not contain new or amended information collection requirements subject
to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information
collection requirements were approved by the Office of Management and Budget,
control number 3150-0011.
1.
Radiological Hazard Assessment and Exposure Controls (71124.01) and
Performance Indicator Verification (71151)
Date of Last Inspection: March 1, 2018
A.
List of contacts and telephone numbers for the Radiation Protection Organization Staff
and Technicians, as well as the Licensing/Regulatory Affairs staff. Please include area
code and prefix. If work cell numbers are appropriate, then please include them as well.
B.
Applicable organization charts including position or job titles. Please include as
appropriate for your site, Site Management, RP, Chemistry, Maintenance (I&C),
Engineering, and Emergency Protection. (Recent pictures are appreciated.)
C.
Copies of audits, self-assessments, LARs, and LERs written since the last inspection
date, related to this inspection area
D.
Procedure indexes for the radiation protection procedures and other related disciplines.
E.
Please provide procedures related to the following areas noted below. Additional
procedures may be requested by number after the inspector reviews the procedure
indexes.
1. Radiation Protection Program
2. Radiation Protection Conduct of Operations, if not included in #1.
3. Personnel Dosimetry
4. Posting of Radiological Areas
5. High Radiation Area Controls
6. RCA Access Controls and Radiation Worker Instructions
7. Conduct of Radiological Surveys
8. Radioactive Source Inventory and Control
9. Fuel Pool Inventory Access and Control
F.
Please provide a list of NRC Regulatory Guides and NUREGs that you are currently
committed to relative to this program. Please include the revision and/or date for the
commitment and where this may be located in your current licensing basis documents.
G.
Please provide a summary list of corrective action documents (including corporate and
sub-tiered systems) since the last inspection date.
1. Initiated by the radiation protection organization
2. Assigned to the radiation protection organization
NOTE: These lists should include a description of the condition that provides sufficient
detail that the inspectors can ascertain the regulatory impact, the significance
level assigned to the condition, the status of the action (e.g., open, working,
closed, etc.) and the search criteria used. Please provide in document formats
which are sortable and searchable so that inspectors can quickly and
efficiently determine appropriate sampling and perform word searches, as
needed. (Excel spreadsheets are the preferred format.) If codes are used,
please provide a legend for each column where a code is used.
H.
List of radiologically significant work activities scheduled to be conducted during the
inspection period. (If the inspection is scheduled during an outage, please also include a list of
work activities greater than 1 rem, scheduled during the outage with the dose estimate for the
work activity.) Please include the radiological risk assigned to each activity.
SUNSI Review
By: RDA
Non-Sensitive
Sensitive
Publicly Available
Non-Publicly Available
Keyword:
OFFICE
SRI:DRP/A
RI:DRP/A
C:DRS/EB1
AC:DRS/EB2
C:DRS/OB
C:DNMS/RIB
NAME
CNewport
JReynoso
VGaddy
JDrake
GWerner
GWarnick
SIGNATURE
/RA/
/RA/
/RA/
/RA/
/RA/
/RA/
DATE
05/02/19
05/02/19
05/06/19
05/02/19
05/05/19
05/07/19
OFFICE
C:DRS/IPAT
AC:DRS/RCB
SPE:DRP/A
BC:DRP/A
NAME
RKellar
NMakris
RAlexander
MHaire
SIGNATURE
/RA/
/RA/
/RA/
DATE
05/06/19
05/07/19
05/02/19