Matls & Safeguards Insp Rept 50-264/76-01 on 760303-04.No Noncompliance Noted.Major Areas Inspected:Physical Inventory & Verification,Review of SNM Records,Depletion Calculations, Matl Transaction Forms & Matl Status ReptsML20137D322 |
Person / Time |
---|
Site: |
Dow Chemical Company |
---|
Issue date: |
03/24/1976 |
---|
From: |
Finley A, Hind J, Holody D NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
---|
To: |
|
---|
Shared Package |
---|
ML20137D185 |
List: |
---|
References |
---|
FOIA-85-256, FOIA-85-258, FOIA-85-259, FOIA-85-261 50-264-76-02, 50-264-76-2, NUDOCS 8508220452 |
Download: ML20137D322 (9) |
|
|
---|
Category:INSPECTION REPORT
MONTHYEARIR 05000264/20242012024-05-22022 May 2024 Dow Chemical Company - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000264/2024201 IR 05000264/20232012023-08-0101 August 2023 Dow Chemical Company - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000264/2023201 - Cover Letter and Enclosure IR 05000264/20222012022-04-15015 April 2022 Dow Chemical Company - U.S. Nuclear Regulatory Commission Routine Inspection Report 05000264/2022201 IR 05000264/20212022021-08-10010 August 2021 Dow Chemical Company U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000264/2021202 IR 05000264/20212012021-05-27027 May 2021 Dow Chemical Company - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000264/2021201 IR 05000264/20192012019-10-30030 October 2019 Dow Chemical Company Nuclear Regulatory Commission Routine Inspection Report No. 05000264/2019201 IR 05000264/20192022019-10-30030 October 2019 Cover Letter - Dow Chemical Company - U.S. Nuclear Regulatory Commission Security Inspection Report No. 05000264/2019202 IR 05000264/20182012018-10-19019 October 2018 Dow Chemical Company - U.S. Nuclear Regulatory Commission Routine Safety Inspection Report No. 05000264/2018201 IR 05000264/20172012017-11-0808 November 2017 Dow Chemical Co., NRC Routine Inspection Report 05000264/2017201 IR 05000264/20162022016-09-16016 September 2016 Dow Chemical Company, NRC Security Related Inspection Report 05000264/2016202 IR 05000264/20162012016-09-14014 September 2016 Dow Chemical Company - NRC Routine Inspection Report 05000264/2016201, July 19-21, 2016 IR 05000264/20142012014-09-15015 September 2014 IR 05000264/2014201 on August 26-28, 2014 at Dow Chemical Company -NRC Routine Inspection Report No. 50-264/2014-201 IR 05000264/20132012013-09-27027 September 2013 IR 05000264-13-201 on August 26-29, 2013 at Dow Chemical Company - NRC Routine Inspection Report IR 05000264/20112012011-07-19019 July 2011 IR 05000264-11-201; on 06/27-30/2011; the Dow Chemical Company; Triga Research Reactor, NRC Inspection Report IR 05000264/20102012010-07-19019 July 2010 IR 05000264-10-201, on 06/23-6/24/10, Dow Chemical Company, NRC Inspection Report IR 05000264/20102022010-07-19019 July 2010 IR 5000264-10-202, on 06/22/2010 - 06/23/2010, for Dow Chemical Company, Security Inspection IR 05000264/20092022010-01-0707 January 2010 IR 05000264-09-202 on 12/09/09 - 12/11/09 for Dow Chemical Company IR 05000002/19640092009-07-0909 July 2009 IR 05000264-09 on 06/22/09 - 06/26/09 for Dow Chemical Co IR 05000264/20072012007-12-28028 December 2007 IR 05000264-07-201, on December 3-6, 2007, Dow Chemical Company, NRC Routine Inspection Report IR 05000264/20062012006-10-17017 October 2006 IR 05000264-06-201, on 09/26-28/2006, Dow Chemical Company IR 05000264/20042012004-08-0606 August 2004 IR 05000264-04-201, on 06/22-24/2004, Dow Nuclear Research Reactor IR 05000264/19992011999-08-10010 August 1999 Insp Rept 50-264/99-201 on 990712-15.No Violations Noted. Major Areas Inspected:Operations Program,Organizational Structure & Functions Program,Design Control Program,Review & Audit Program & Radiation Protection Program IR 05000254/19980021998-02-0505 February 1998 Insp Repts 50-254/98-02 & 50-265/98-02 on 980112-16. Violations Noted.Major Areas Inspected:Review of ALARA Planning,Radiation Work Permits & Observations of Radworker Performance IR 05000264/19972011997-12-18018 December 1997 Insp Rept 50-264/97-201 on 971202-03.No Violations or Deviations Noted.Major Areas Inspected:Aspects of Surveillance,Experiments,Radiation Controls,Design Change & Emergency Preparedness (69001) IR 05000264/19970011997-04-23023 April 1997 Insp Rept 50-264/97-01 on 970407-11.No Violations Noted. Major Areas Inspected:Organization,Periodic & Special Repts, Operations & Maint,Operations & Maint Procedures, Requalification Training,Surveillance & Experiments IR 05000264/19900011990-08-0101 August 1990 Insp Rept 50-264/90-01 on 900709-11.No Violations or Deviations Noted.Major Areas Inspected:Organization,Logs, Review & Audit Functions,Requalification Training, Procedures,Surveillance & Emergency Planning IR 05000264/19890021989-09-0707 September 1989 Insp Rept 50-264/89-02 on 890829-30.No Violations Noted. Major Areas Inspected:Snm Control & Accountability Including Possession & Use of SNM & Accounting of Snm,Review of Facility Organization & Operation & Shipping & Receiving IR 05000264/19890011989-09-0505 September 1989 Physical Security Insp Rept 50-264/89-01 on 890829-30.No Violations Noted.Major Areas Inspected:Review of Approved Security Plan,Including Plans,Procedures,Revs,Repts of Safeguards Events & Physical Protection of SNM IR 05000264/19860011986-12-0404 December 1986 Insp Rept 50-264/86-01 on 861118-21.No Violations or Deviations Noted.Major Areas Inspected:Records,Logs & Organization,Review & Audit Functions,Requalification Training,Procedures,Surveillance Activities & LERs IR 05000264/19850021985-06-12012 June 1985 Matl Control & Accountability Insp Rept 50-264/85-02 on 850603-04.No Noncompliance Noted.Major Areas Inspected: Possession & Use of SNM & Control & Accounting of Snm. Details Withheld (Ref 10CFR2.790) IR 05000264/19850011985-06-12012 June 1985 Insp Rept 50-264/85-01 on 850603-04.No Noncompliance Noted. Major Areas inspected:781005 Security Plan.Details Withheld (Ref 10CFR2.790) IR 05000264/19830021983-07-29029 July 1983 IE Insp Rept 50-264/83-02 on 830629-30.No Noncompliance Noted.Major Areas Inspected:Radiation Protection & Radwaste Mgt Programs,Including Qualifications,Audits,Training, Radiation Protection Procedures & Instruments & Equipment IR 05000264/19830011983-04-29029 April 1983 Sanitized Version of Matl Control & Accounting Insp Rept 50-264/83-01 on 830405-06.No Noncompliance Noted.Major Areas Inspected:Facility Organization & Operation,Measurement & Statistical Control & Storage & Internal Controls IR 05000264/19810021982-01-11011 January 1982 IE Insp Repts 50-264/81-02 & 70-1487/81-01 on 811207-10. No Noncompliance Noted.Major Areas Inspected:Followup on IE Circulars,Lers & Open Insp Items & Review of Records,Logs & Organization IR 05000264/19810011981-01-23023 January 1981 IE Insp Rept 50-264/81-01 on 810112-14.No Noncompliance Noted.Major Areas Inspected:Records,Logs & Organization, Review & Audit Functions,Requalification Training, Surveillance & Maint & Experiments IR 05000264/19800021980-09-22022 September 1980 IE Insp Rept 50-264/80-02 on 800910-12.No Noncompliance Noted.Major Areas Inspected:Qualifications,Audits,Training, Radiation Protection Procedures,Instruments & Equipment Exposure Control IR 05000264/19800011980-09-15015 September 1980 IE Insp Rept 50-264/80-01 on 800828-29.No Noncompliance Noted.Major Areas Inspected:Emergency Planning,Facilities, Equipment,Drills & Training IR 05000264/19790031979-12-0303 December 1979 IE Insp Rept 50-264/79-03 on 791022-24.Noncompliance Noted: Failure to Perform Monthly Checklist in June IR 05000264/19790021979-11-28028 November 1979 Ack Receipt of Informing NRC of Steps Taken to Correct Violation Noted in IE Insp Rept 50-264/79-02 ML19210E5721979-10-22022 October 1979 IE Insp Rept 50-264/79-02 on 791002-03.Noncompliance Noted: Failure of Reactor Operations Committee to Meet Quarterly IR 05000264/19790011979-05-0303 May 1979 IE Insp Rept 50-264/79-01 on 790411-12.No Noncompliance Noted.Major Areas Inspected:Security Plan.Details Withheld (Ref 10CFR2.790) IR 05000264/19780041978-12-27027 December 1978 IE Insp Rept 50-264/78-04 on 781116-17.No Noncompliance Noted.Major Areas Inspected:Special Nuclear Matl Control & Accountability Including Facility Organization & Operation Measurement & Controls,Inventory & Shipping IR 05000264/19780011978-07-11011 July 1978 Insp Rept 50-264/78-01 on 780110-12.Noncompliance Noted Re Security Organization & Access Controls.Portions Deleted (Ref 10CFR2.790).Written Statement in Reply to Notice of Violation Encl IR 05000264/19780021978-06-0606 June 1978 Insp Rept 50-264/78-02 on 780503-04.No Noncompliance or Deviations Identified.Areas Inspected:Radwaste Mgt & Radiation Protection Program,Including Qualifications, Audits,Training,Equipment & Instruments IR 05000264/19770031977-08-24024 August 1977 Insp Rept 50-264/77-03 on 770809-11.No Noncompliance or Deviations Identified.Areas Inspected:Emergency Planning, Including Review of Emergency Plan & Implementing Procedures & Interviews W/Licensee Personnel IR 05000264/19770021977-08-17017 August 1977 Insp Rept 50-264/77-02 on 770719-22,26 & 27.No Noncompliance Noted.Major Areas Inspected:Reactor Startup & Routine Operation IR 05000264/19770011977-05-11011 May 1977 Insp Rept 50-264/77-01 on 770425-26.No Noncompliance or Deviations Identified.Area Inspected:Facilities & Equipment, Organization,Training,Radiation Protection Procedures & Health Physics Instrumentation IR 05000264/19760031976-04-20020 April 1976 Insp Rept 50-264/76-03 on 760407.No Noncompliance Identified.Area Inspected:Radiation Protection & Radwaste Programs,Including Records,Procedures,Equipment Inventory & Interviews W/Personnel IR 05000264/19760021976-03-29029 March 1976 Forwards Insp Rept 50-264/76-02 on 760303 & 04.No Noncompliance Noted IR 05000264/19760011976-03-24024 March 1976 Matls & Safeguards Insp Rept 50-264/76-01 on 760303-04.No Noncompliance Noted.Major Areas Inspected:Physical Inventory & Verification,Review of SNM Records,Depletion Calculations, Matl Transaction Forms & Matl Status Repts 2024-05-22
[Table view] Category:MANUFACTURER/VENDOR/ENGINEER
MONTHYEARIR 05000264/19890021989-09-0707 September 1989 Insp Rept 50-264/89-02 on 890829-30.No Violations Noted. Major Areas Inspected:Snm Control & Accountability Including Possession & Use of SNM & Accounting of Snm,Review of Facility Organization & Operation & Shipping & Receiving IR 05000264/19890011989-09-0505 September 1989 Physical Security Insp Rept 50-264/89-01 on 890829-30.No Violations Noted.Major Areas Inspected:Review of Approved Security Plan,Including Plans,Procedures,Revs,Repts of Safeguards Events & Physical Protection of SNM IR 05000264/19860011986-12-0404 December 1986 Insp Rept 50-264/86-01 on 861118-21.No Violations or Deviations Noted.Major Areas Inspected:Records,Logs & Organization,Review & Audit Functions,Requalification Training,Procedures,Surveillance Activities & LERs IR 05000264/19850021985-06-12012 June 1985 Matl Control & Accountability Insp Rept 50-264/85-02 on 850603-04.No Noncompliance Noted.Major Areas Inspected: Possession & Use of SNM & Control & Accounting of Snm. Details Withheld (Ref 10CFR2.790) IR 05000264/19850011985-06-12012 June 1985 Insp Rept 50-264/85-01 on 850603-04.No Noncompliance Noted. Major Areas inspected:781005 Security Plan.Details Withheld (Ref 10CFR2.790) IR 05000264/19830021983-07-29029 July 1983 IE Insp Rept 50-264/83-02 on 830629-30.No Noncompliance Noted.Major Areas Inspected:Radiation Protection & Radwaste Mgt Programs,Including Qualifications,Audits,Training, Radiation Protection Procedures & Instruments & Equipment IR 05000264/19830011983-04-29029 April 1983 Sanitized Version of Matl Control & Accounting Insp Rept 50-264/83-01 on 830405-06.No Noncompliance Noted.Major Areas Inspected:Facility Organization & Operation,Measurement & Statistical Control & Storage & Internal Controls IR 05000264/19810021982-01-11011 January 1982 IE Insp Repts 50-264/81-02 & 70-1487/81-01 on 811207-10. No Noncompliance Noted.Major Areas Inspected:Followup on IE Circulars,Lers & Open Insp Items & Review of Records,Logs & Organization IR 05000264/19810011981-01-23023 January 1981 IE Insp Rept 50-264/81-01 on 810112-14.No Noncompliance Noted.Major Areas Inspected:Records,Logs & Organization, Review & Audit Functions,Requalification Training, Surveillance & Maint & Experiments IR 05000264/19800021980-09-22022 September 1980 IE Insp Rept 50-264/80-02 on 800910-12.No Noncompliance Noted.Major Areas Inspected:Qualifications,Audits,Training, Radiation Protection Procedures,Instruments & Equipment Exposure Control IR 05000264/19800011980-09-15015 September 1980 IE Insp Rept 50-264/80-01 on 800828-29.No Noncompliance Noted.Major Areas Inspected:Emergency Planning,Facilities, Equipment,Drills & Training IR 05000264/19790031979-12-0303 December 1979 IE Insp Rept 50-264/79-03 on 791022-24.Noncompliance Noted: Failure to Perform Monthly Checklist in June ML19210E5721979-10-22022 October 1979 IE Insp Rept 50-264/79-02 on 791002-03.Noncompliance Noted: Failure of Reactor Operations Committee to Meet Quarterly IR 05000264/19790011979-05-0303 May 1979 IE Insp Rept 50-264/79-01 on 790411-12.No Noncompliance Noted.Major Areas Inspected:Security Plan.Details Withheld (Ref 10CFR2.790) IR 05000264/19780041978-12-27027 December 1978 IE Insp Rept 50-264/78-04 on 781116-17.No Noncompliance Noted.Major Areas Inspected:Special Nuclear Matl Control & Accountability Including Facility Organization & Operation Measurement & Controls,Inventory & Shipping IR 05000264/19780011978-07-11011 July 1978 Insp Rept 50-264/78-01 on 780110-12.Noncompliance Noted Re Security Organization & Access Controls.Portions Deleted (Ref 10CFR2.790).Written Statement in Reply to Notice of Violation Encl IR 05000264/19780021978-06-0606 June 1978 Insp Rept 50-264/78-02 on 780503-04.No Noncompliance or Deviations Identified.Areas Inspected:Radwaste Mgt & Radiation Protection Program,Including Qualifications, Audits,Training,Equipment & Instruments IR 05000264/19770031977-08-24024 August 1977 Insp Rept 50-264/77-03 on 770809-11.No Noncompliance or Deviations Identified.Areas Inspected:Emergency Planning, Including Review of Emergency Plan & Implementing Procedures & Interviews W/Licensee Personnel IR 05000264/19770021977-08-17017 August 1977 Insp Rept 50-264/77-02 on 770719-22,26 & 27.No Noncompliance Noted.Major Areas Inspected:Reactor Startup & Routine Operation IR 05000264/19770011977-05-11011 May 1977 Insp Rept 50-264/77-01 on 770425-26.No Noncompliance or Deviations Identified.Area Inspected:Facilities & Equipment, Organization,Training,Radiation Protection Procedures & Health Physics Instrumentation IR 05000264/19760031976-04-20020 April 1976 Insp Rept 50-264/76-03 on 760407.No Noncompliance Identified.Area Inspected:Radiation Protection & Radwaste Programs,Including Records,Procedures,Equipment Inventory & Interviews W/Personnel IR 05000264/19760011976-03-24024 March 1976 Matls & Safeguards Insp Rept 50-264/76-01 on 760303-04.No Noncompliance Noted.Major Areas Inspected:Physical Inventory & Verification,Review of SNM Records,Depletion Calculations, Matl Transaction Forms & Matl Status Repts IR 05000264/19750011975-10-15015 October 1975 Insp Rept 50-264/75-01 on 750922-24.No Noncompliance Noted. Major Areas Inspected:Reactor Operations,Maint, Implementation of Modified Operator Requalification Program & Corrective Action on Noncompliance Item 73-01 IR 05000264/19740011974-04-0202 April 1974 RO Insp Rept 50-264/74-01 on 740306 & 07.No Violations Noted.Areas Inspected:Personnel Monitoring,Surveys & Survey Instruments,Rabbit Sys,Radwaste,Area Radiation Monitor,Water Monitor & Continuous Air Monitor IR 05000264/19730011973-10-24024 October 1973 Insp Rept 50-264/73-01 on 730920 & 21.Violations Noted: Reactor Operated W/Greater than 1.5% Delta K/K Excess Reactivity on 730125 Change to Operating Procedure Inserted in Operating Log,W/O Formal Approval ML20137G6141971-06-22022 June 1971 Insp Rept 50-264/71-01 on 710602.No Deficiencies or Unresolved Items Found.Major Areas Inspected:Reporting Requirements Per 10CFR50.59 & Div of Compliance Procedures for Documentation,Records,Reactivity Control & Core Physics ML20136H1721971-06-0202 June 1971 Expanded Field Notes for Co Rept 50-264/71-01 on 710602. Areas Discussed:Administration & Organization Operations, Facility Procedures,Primary Sys,Reactor Controls & Core Physics,Functional Tests,Safety Circuitry & Core Internals ML20136H0411969-04-15015 April 1969 Co Insp Rept 50-264/69-01 on 690402.No Safety,Noncompliance or Unusual Occurrences Noted.Areas Inspected:Reactor Operation ML20137G9081968-10-17017 October 1968 Insp Rept 50-264/68-01 on 680926.No Noncompliance Noted. Major Areas Inspected:Visual Insp of Fuel Elements & Control ML20137G9261967-11-0707 November 1967 Insp Rept 50-264/67-03 on 671025-26.No Noncompliance Noted. Major Areas Inspected:Reviews of Reactor post-critical Performance Data & Appropriate Log Books,Observation of Startup & Discussions W/Personnel ML20137G4781967-07-14014 July 1967 Insp Rept 50-264/67-02 on 670630.No Safety Items or Noncompliance Noted.Major Areas Inspected:Completion of Unresolved Items Listed in App B to Insp Rept 50-264/67-01. Initial Criticality Observed During 670705-06 Visit ML20137G4171967-06-26026 June 1967 Insp Rept 50-264/67-01 on 670620 & 21.Deviations Noted: Manually Operated Louvres Installed as Backup to Automatic Louvres in Ventilation Intake & Exhaust Ducts & Reactor Room Area Monitor Placed on East Wall Rather than CRD Platform 1989-09-07
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000264/20242012024-05-22022 May 2024 Dow Chemical Company - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000264/2024201 IR 05000264/20232012023-08-0101 August 2023 Dow Chemical Company - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000264/2023201 - Cover Letter and Enclosure IR 05000264/20222012022-04-15015 April 2022 Dow Chemical Company - U.S. Nuclear Regulatory Commission Routine Inspection Report 05000264/2022201 IR 05000264/20212022021-08-10010 August 2021 Dow Chemical Company U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000264/2021202 IR 05000264/20212012021-05-27027 May 2021 Dow Chemical Company - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000264/2021201 IR 05000264/20192012019-10-30030 October 2019 Dow Chemical Company Nuclear Regulatory Commission Routine Inspection Report No. 05000264/2019201 IR 05000264/20192022019-10-30030 October 2019 Cover Letter - Dow Chemical Company - U.S. Nuclear Regulatory Commission Security Inspection Report No. 05000264/2019202 IR 05000264/20182012018-10-19019 October 2018 Dow Chemical Company - U.S. Nuclear Regulatory Commission Routine Safety Inspection Report No. 05000264/2018201 IR 05000264/20172012017-11-0808 November 2017 Dow Chemical Co., NRC Routine Inspection Report 05000264/2017201 IR 05000264/20162022016-09-16016 September 2016 Dow Chemical Company, NRC Security Related Inspection Report 05000264/2016202 IR 05000264/20162012016-09-14014 September 2016 Dow Chemical Company - NRC Routine Inspection Report 05000264/2016201, July 19-21, 2016 IR 05000264/20142012014-09-15015 September 2014 IR 05000264/2014201 on August 26-28, 2014 at Dow Chemical Company -NRC Routine Inspection Report No. 50-264/2014-201 IR 05000264/20132012013-09-27027 September 2013 IR 05000264-13-201 on August 26-29, 2013 at Dow Chemical Company - NRC Routine Inspection Report IR 05000264/20112012011-07-19019 July 2011 IR 05000264-11-201; on 06/27-30/2011; the Dow Chemical Company; Triga Research Reactor, NRC Inspection Report IR 05000264/20102012010-07-19019 July 2010 IR 05000264-10-201, on 06/23-6/24/10, Dow Chemical Company, NRC Inspection Report IR 05000264/20102022010-07-19019 July 2010 IR 5000264-10-202, on 06/22/2010 - 06/23/2010, for Dow Chemical Company, Security Inspection IR 05000264/20092022010-01-0707 January 2010 IR 05000264-09-202 on 12/09/09 - 12/11/09 for Dow Chemical Company IR 05000002/19640092009-07-0909 July 2009 IR 05000264-09 on 06/22/09 - 06/26/09 for Dow Chemical Co IR 05000264/20072012007-12-28028 December 2007 IR 05000264-07-201, on December 3-6, 2007, Dow Chemical Company, NRC Routine Inspection Report IR 05000264/20062012006-10-17017 October 2006 IR 05000264-06-201, on 09/26-28/2006, Dow Chemical Company IR 05000264/20042012004-08-0606 August 2004 IR 05000264-04-201, on 06/22-24/2004, Dow Nuclear Research Reactor IR 05000264/19992011999-08-10010 August 1999 Insp Rept 50-264/99-201 on 990712-15.No Violations Noted. Major Areas Inspected:Operations Program,Organizational Structure & Functions Program,Design Control Program,Review & Audit Program & Radiation Protection Program IR 05000254/19980021998-02-0505 February 1998 Insp Repts 50-254/98-02 & 50-265/98-02 on 980112-16. Violations Noted.Major Areas Inspected:Review of ALARA Planning,Radiation Work Permits & Observations of Radworker Performance IR 05000264/19972011997-12-18018 December 1997 Insp Rept 50-264/97-201 on 971202-03.No Violations or Deviations Noted.Major Areas Inspected:Aspects of Surveillance,Experiments,Radiation Controls,Design Change & Emergency Preparedness (69001) IR 05000264/19970011997-04-23023 April 1997 Insp Rept 50-264/97-01 on 970407-11.No Violations Noted. Major Areas Inspected:Organization,Periodic & Special Repts, Operations & Maint,Operations & Maint Procedures, Requalification Training,Surveillance & Experiments IR 05000264/19900011990-08-0101 August 1990 Insp Rept 50-264/90-01 on 900709-11.No Violations or Deviations Noted.Major Areas Inspected:Organization,Logs, Review & Audit Functions,Requalification Training, Procedures,Surveillance & Emergency Planning IR 05000264/19890021989-09-0707 September 1989 Insp Rept 50-264/89-02 on 890829-30.No Violations Noted. Major Areas Inspected:Snm Control & Accountability Including Possession & Use of SNM & Accounting of Snm,Review of Facility Organization & Operation & Shipping & Receiving IR 05000264/19890011989-09-0505 September 1989 Physical Security Insp Rept 50-264/89-01 on 890829-30.No Violations Noted.Major Areas Inspected:Review of Approved Security Plan,Including Plans,Procedures,Revs,Repts of Safeguards Events & Physical Protection of SNM IR 05000264/19860011986-12-0404 December 1986 Insp Rept 50-264/86-01 on 861118-21.No Violations or Deviations Noted.Major Areas Inspected:Records,Logs & Organization,Review & Audit Functions,Requalification Training,Procedures,Surveillance Activities & LERs IR 05000264/19850021985-06-12012 June 1985 Matl Control & Accountability Insp Rept 50-264/85-02 on 850603-04.No Noncompliance Noted.Major Areas Inspected: Possession & Use of SNM & Control & Accounting of Snm. Details Withheld (Ref 10CFR2.790) IR 05000264/19850011985-06-12012 June 1985 Insp Rept 50-264/85-01 on 850603-04.No Noncompliance Noted. Major Areas inspected:781005 Security Plan.Details Withheld (Ref 10CFR2.790) IR 05000264/19830021983-07-29029 July 1983 IE Insp Rept 50-264/83-02 on 830629-30.No Noncompliance Noted.Major Areas Inspected:Radiation Protection & Radwaste Mgt Programs,Including Qualifications,Audits,Training, Radiation Protection Procedures & Instruments & Equipment IR 05000264/19830011983-04-29029 April 1983 Sanitized Version of Matl Control & Accounting Insp Rept 50-264/83-01 on 830405-06.No Noncompliance Noted.Major Areas Inspected:Facility Organization & Operation,Measurement & Statistical Control & Storage & Internal Controls IR 05000264/19810021982-01-11011 January 1982 IE Insp Repts 50-264/81-02 & 70-1487/81-01 on 811207-10. No Noncompliance Noted.Major Areas Inspected:Followup on IE Circulars,Lers & Open Insp Items & Review of Records,Logs & Organization IR 05000264/19810011981-01-23023 January 1981 IE Insp Rept 50-264/81-01 on 810112-14.No Noncompliance Noted.Major Areas Inspected:Records,Logs & Organization, Review & Audit Functions,Requalification Training, Surveillance & Maint & Experiments IR 05000264/19800021980-09-22022 September 1980 IE Insp Rept 50-264/80-02 on 800910-12.No Noncompliance Noted.Major Areas Inspected:Qualifications,Audits,Training, Radiation Protection Procedures,Instruments & Equipment Exposure Control IR 05000264/19800011980-09-15015 September 1980 IE Insp Rept 50-264/80-01 on 800828-29.No Noncompliance Noted.Major Areas Inspected:Emergency Planning,Facilities, Equipment,Drills & Training IR 05000264/19790031979-12-0303 December 1979 IE Insp Rept 50-264/79-03 on 791022-24.Noncompliance Noted: Failure to Perform Monthly Checklist in June IR 05000264/19790021979-11-28028 November 1979 Ack Receipt of Informing NRC of Steps Taken to Correct Violation Noted in IE Insp Rept 50-264/79-02 ML19210E5721979-10-22022 October 1979 IE Insp Rept 50-264/79-02 on 791002-03.Noncompliance Noted: Failure of Reactor Operations Committee to Meet Quarterly IR 05000264/19790011979-05-0303 May 1979 IE Insp Rept 50-264/79-01 on 790411-12.No Noncompliance Noted.Major Areas Inspected:Security Plan.Details Withheld (Ref 10CFR2.790) IR 05000264/19780041978-12-27027 December 1978 IE Insp Rept 50-264/78-04 on 781116-17.No Noncompliance Noted.Major Areas Inspected:Special Nuclear Matl Control & Accountability Including Facility Organization & Operation Measurement & Controls,Inventory & Shipping IR 05000264/19780011978-07-11011 July 1978 Insp Rept 50-264/78-01 on 780110-12.Noncompliance Noted Re Security Organization & Access Controls.Portions Deleted (Ref 10CFR2.790).Written Statement in Reply to Notice of Violation Encl IR 05000264/19780021978-06-0606 June 1978 Insp Rept 50-264/78-02 on 780503-04.No Noncompliance or Deviations Identified.Areas Inspected:Radwaste Mgt & Radiation Protection Program,Including Qualifications, Audits,Training,Equipment & Instruments IR 05000264/19770031977-08-24024 August 1977 Insp Rept 50-264/77-03 on 770809-11.No Noncompliance or Deviations Identified.Areas Inspected:Emergency Planning, Including Review of Emergency Plan & Implementing Procedures & Interviews W/Licensee Personnel IR 05000264/19770021977-08-17017 August 1977 Insp Rept 50-264/77-02 on 770719-22,26 & 27.No Noncompliance Noted.Major Areas Inspected:Reactor Startup & Routine Operation IR 05000264/19770011977-05-11011 May 1977 Insp Rept 50-264/77-01 on 770425-26.No Noncompliance or Deviations Identified.Area Inspected:Facilities & Equipment, Organization,Training,Radiation Protection Procedures & Health Physics Instrumentation IR 05000264/19760031976-04-20020 April 1976 Insp Rept 50-264/76-03 on 760407.No Noncompliance Identified.Area Inspected:Radiation Protection & Radwaste Programs,Including Records,Procedures,Equipment Inventory & Interviews W/Personnel IR 05000264/19760021976-03-29029 March 1976 Forwards Insp Rept 50-264/76-02 on 760303 & 04.No Noncompliance Noted IR 05000264/19760011976-03-24024 March 1976 Matls & Safeguards Insp Rept 50-264/76-01 on 760303-04.No Noncompliance Noted.Major Areas Inspected:Physical Inventory & Verification,Review of SNM Records,Depletion Calculations, Matl Transaction Forms & Matl Status Repts 2024-05-22
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000264/19992011999-08-10010 August 1999 Insp Rept 50-264/99-201 on 990712-15.No Violations Noted. Major Areas Inspected:Operations Program,Organizational Structure & Functions Program,Design Control Program,Review & Audit Program & Radiation Protection Program IR 05000254/19980021998-02-0505 February 1998 Insp Repts 50-254/98-02 & 50-265/98-02 on 980112-16. Violations Noted.Major Areas Inspected:Review of ALARA Planning,Radiation Work Permits & Observations of Radworker Performance IR 05000264/19972011997-12-18018 December 1997 Insp Rept 50-264/97-201 on 971202-03.No Violations or Deviations Noted.Major Areas Inspected:Aspects of Surveillance,Experiments,Radiation Controls,Design Change & Emergency Preparedness (69001) IR 05000264/19970011997-04-23023 April 1997 Insp Rept 50-264/97-01 on 970407-11.No Violations Noted. Major Areas Inspected:Organization,Periodic & Special Repts, Operations & Maint,Operations & Maint Procedures, Requalification Training,Surveillance & Experiments IR 05000264/19900011990-08-0101 August 1990 Insp Rept 50-264/90-01 on 900709-11.No Violations or Deviations Noted.Major Areas Inspected:Organization,Logs, Review & Audit Functions,Requalification Training, Procedures,Surveillance & Emergency Planning IR 05000264/19890021989-09-0707 September 1989 Insp Rept 50-264/89-02 on 890829-30.No Violations Noted. Major Areas Inspected:Snm Control & Accountability Including Possession & Use of SNM & Accounting of Snm,Review of Facility Organization & Operation & Shipping & Receiving IR 05000264/19890011989-09-0505 September 1989 Physical Security Insp Rept 50-264/89-01 on 890829-30.No Violations Noted.Major Areas Inspected:Review of Approved Security Plan,Including Plans,Procedures,Revs,Repts of Safeguards Events & Physical Protection of SNM IR 05000264/19860011986-12-0404 December 1986 Insp Rept 50-264/86-01 on 861118-21.No Violations or Deviations Noted.Major Areas Inspected:Records,Logs & Organization,Review & Audit Functions,Requalification Training,Procedures,Surveillance Activities & LERs IR 05000264/19850011985-06-12012 June 1985 Insp Rept 50-264/85-01 on 850603-04.No Noncompliance Noted. Major Areas inspected:781005 Security Plan.Details Withheld (Ref 10CFR2.790) IR 05000264/19850021985-06-12012 June 1985 Matl Control & Accountability Insp Rept 50-264/85-02 on 850603-04.No Noncompliance Noted.Major Areas Inspected: Possession & Use of SNM & Control & Accounting of Snm. Details Withheld (Ref 10CFR2.790) IR 05000264/19830021983-07-29029 July 1983 IE Insp Rept 50-264/83-02 on 830629-30.No Noncompliance Noted.Major Areas Inspected:Radiation Protection & Radwaste Mgt Programs,Including Qualifications,Audits,Training, Radiation Protection Procedures & Instruments & Equipment IR 05000264/19830011983-04-29029 April 1983 Sanitized Version of Matl Control & Accounting Insp Rept 50-264/83-01 on 830405-06.No Noncompliance Noted.Major Areas Inspected:Facility Organization & Operation,Measurement & Statistical Control & Storage & Internal Controls IR 05000264/19810021982-01-11011 January 1982 IE Insp Repts 50-264/81-02 & 70-1487/81-01 on 811207-10. No Noncompliance Noted.Major Areas Inspected:Followup on IE Circulars,Lers & Open Insp Items & Review of Records,Logs & Organization IR 05000264/19810011981-01-23023 January 1981 IE Insp Rept 50-264/81-01 on 810112-14.No Noncompliance Noted.Major Areas Inspected:Records,Logs & Organization, Review & Audit Functions,Requalification Training, Surveillance & Maint & Experiments IR 05000264/19800021980-09-22022 September 1980 IE Insp Rept 50-264/80-02 on 800910-12.No Noncompliance Noted.Major Areas Inspected:Qualifications,Audits,Training, Radiation Protection Procedures,Instruments & Equipment Exposure Control IR 05000264/19800011980-09-15015 September 1980 IE Insp Rept 50-264/80-01 on 800828-29.No Noncompliance Noted.Major Areas Inspected:Emergency Planning,Facilities, Equipment,Drills & Training IR 05000264/19790031979-12-0303 December 1979 IE Insp Rept 50-264/79-03 on 791022-24.Noncompliance Noted: Failure to Perform Monthly Checklist in June ML19210E5721979-10-22022 October 1979 IE Insp Rept 50-264/79-02 on 791002-03.Noncompliance Noted: Failure of Reactor Operations Committee to Meet Quarterly IR 05000264/19790011979-05-0303 May 1979 IE Insp Rept 50-264/79-01 on 790411-12.No Noncompliance Noted.Major Areas Inspected:Security Plan.Details Withheld (Ref 10CFR2.790) IR 05000264/19780041978-12-27027 December 1978 IE Insp Rept 50-264/78-04 on 781116-17.No Noncompliance Noted.Major Areas Inspected:Special Nuclear Matl Control & Accountability Including Facility Organization & Operation Measurement & Controls,Inventory & Shipping IR 05000264/19780011978-07-11011 July 1978 Insp Rept 50-264/78-01 on 780110-12.Noncompliance Noted Re Security Organization & Access Controls.Portions Deleted (Ref 10CFR2.790).Written Statement in Reply to Notice of Violation Encl IR 05000264/19780021978-06-0606 June 1978 Insp Rept 50-264/78-02 on 780503-04.No Noncompliance or Deviations Identified.Areas Inspected:Radwaste Mgt & Radiation Protection Program,Including Qualifications, Audits,Training,Equipment & Instruments IR 05000264/19770031977-08-24024 August 1977 Insp Rept 50-264/77-03 on 770809-11.No Noncompliance or Deviations Identified.Areas Inspected:Emergency Planning, Including Review of Emergency Plan & Implementing Procedures & Interviews W/Licensee Personnel IR 05000264/19770021977-08-17017 August 1977 Insp Rept 50-264/77-02 on 770719-22,26 & 27.No Noncompliance Noted.Major Areas Inspected:Reactor Startup & Routine Operation IR 05000264/19770011977-05-11011 May 1977 Insp Rept 50-264/77-01 on 770425-26.No Noncompliance or Deviations Identified.Area Inspected:Facilities & Equipment, Organization,Training,Radiation Protection Procedures & Health Physics Instrumentation IR 05000264/19760031976-04-20020 April 1976 Insp Rept 50-264/76-03 on 760407.No Noncompliance Identified.Area Inspected:Radiation Protection & Radwaste Programs,Including Records,Procedures,Equipment Inventory & Interviews W/Personnel IR 05000264/19760011976-03-24024 March 1976 Matls & Safeguards Insp Rept 50-264/76-01 on 760303-04.No Noncompliance Noted.Major Areas Inspected:Physical Inventory & Verification,Review of SNM Records,Depletion Calculations, Matl Transaction Forms & Matl Status Repts IR 05000264/19750011975-10-15015 October 1975 Insp Rept 50-264/75-01 on 750922-24.No Noncompliance Noted. Major Areas Inspected:Reactor Operations,Maint, Implementation of Modified Operator Requalification Program & Corrective Action on Noncompliance Item 73-01 IR 05000264/19740011974-04-0202 April 1974 RO Insp Rept 50-264/74-01 on 740306 & 07.No Violations Noted.Areas Inspected:Personnel Monitoring,Surveys & Survey Instruments,Rabbit Sys,Radwaste,Area Radiation Monitor,Water Monitor & Continuous Air Monitor IR 05000264/19730011973-10-24024 October 1973 Insp Rept 50-264/73-01 on 730920 & 21.Violations Noted: Reactor Operated W/Greater than 1.5% Delta K/K Excess Reactivity on 730125 Change to Operating Procedure Inserted in Operating Log,W/O Formal Approval ML20137G6141971-06-22022 June 1971 Insp Rept 50-264/71-01 on 710602.No Deficiencies or Unresolved Items Found.Major Areas Inspected:Reporting Requirements Per 10CFR50.59 & Div of Compliance Procedures for Documentation,Records,Reactivity Control & Core Physics ML20136H1721971-06-0202 June 1971 Expanded Field Notes for Co Rept 50-264/71-01 on 710602. Areas Discussed:Administration & Organization Operations, Facility Procedures,Primary Sys,Reactor Controls & Core Physics,Functional Tests,Safety Circuitry & Core Internals ML20136H0411969-04-15015 April 1969 Co Insp Rept 50-264/69-01 on 690402.No Safety,Noncompliance or Unusual Occurrences Noted.Areas Inspected:Reactor Operation ML20137G9081968-10-17017 October 1968 Insp Rept 50-264/68-01 on 680926.No Noncompliance Noted. Major Areas Inspected:Visual Insp of Fuel Elements & Control ML20137G9261967-11-0707 November 1967 Insp Rept 50-264/67-03 on 671025-26.No Noncompliance Noted. Major Areas Inspected:Reviews of Reactor post-critical Performance Data & Appropriate Log Books,Observation of Startup & Discussions W/Personnel ML20137G4781967-07-14014 July 1967 Insp Rept 50-264/67-02 on 670630.No Safety Items or Noncompliance Noted.Major Areas Inspected:Completion of Unresolved Items Listed in App B to Insp Rept 50-264/67-01. Initial Criticality Observed During 670705-06 Visit ML20137G4171967-06-26026 June 1967 Insp Rept 50-264/67-01 on 670620 & 21.Deviations Noted: Manually Operated Louvres Installed as Backup to Automatic Louvres in Ventilation Intake & Exhaust Ducts & Reactor Room Area Monitor Placed on East Wall Rather than CRD Platform 1999-08-10
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000264/19992011999-08-10010 August 1999 Insp Rept 50-264/99-201 on 990712-15.No Violations Noted. Major Areas Inspected:Operations Program,Organizational Structure & Functions Program,Design Control Program,Review & Audit Program & Radiation Protection Program IR 05000254/19980021998-02-0505 February 1998 Insp Repts 50-254/98-02 & 50-265/98-02 on 980112-16. Violations Noted.Major Areas Inspected:Review of ALARA Planning,Radiation Work Permits & Observations of Radworker Performance IR 05000264/19972011997-12-18018 December 1997 Insp Rept 50-264/97-201 on 971202-03.No Violations or Deviations Noted.Major Areas Inspected:Aspects of Surveillance,Experiments,Radiation Controls,Design Change & Emergency Preparedness (69001) IR 05000264/19970011997-04-23023 April 1997 Insp Rept 50-264/97-01 on 970407-11.No Violations Noted. Major Areas Inspected:Organization,Periodic & Special Repts, Operations & Maint,Operations & Maint Procedures, Requalification Training,Surveillance & Experiments IR 05000264/19900011990-08-0101 August 1990 Insp Rept 50-264/90-01 on 900709-11.No Violations or Deviations Noted.Major Areas Inspected:Organization,Logs, Review & Audit Functions,Requalification Training, Procedures,Surveillance & Emergency Planning IR 05000264/19890021989-09-0707 September 1989 Insp Rept 50-264/89-02 on 890829-30.No Violations Noted. Major Areas Inspected:Snm Control & Accountability Including Possession & Use of SNM & Accounting of Snm,Review of Facility Organization & Operation & Shipping & Receiving IR 05000264/19890011989-09-0505 September 1989 Physical Security Insp Rept 50-264/89-01 on 890829-30.No Violations Noted.Major Areas Inspected:Review of Approved Security Plan,Including Plans,Procedures,Revs,Repts of Safeguards Events & Physical Protection of SNM ML20237E1521987-12-22022 December 1987 Exam Rept 50-264/OLS-87-01 on 871201-02.Exam Results: Candidate Passed IR 05000264/19860011986-12-0404 December 1986 Insp Rept 50-264/86-01 on 861118-21.No Violations or Deviations Noted.Major Areas Inspected:Records,Logs & Organization,Review & Audit Functions,Requalification Training,Procedures,Surveillance Activities & LERs IR 05000264/19850021985-06-12012 June 1985 Matl Control & Accountability Insp Rept 50-264/85-02 on 850603-04.No Noncompliance Noted.Major Areas Inspected: Possession & Use of SNM & Control & Accounting of Snm. Details Withheld (Ref 10CFR2.790) IR 05000264/19850011985-06-12012 June 1985 Insp Rept 50-264/85-01 on 850603-04.No Noncompliance Noted. Major Areas inspected:781005 Security Plan.Details Withheld (Ref 10CFR2.790) IR 05000264/19830021983-07-29029 July 1983 IE Insp Rept 50-264/83-02 on 830629-30.No Noncompliance Noted.Major Areas Inspected:Radiation Protection & Radwaste Mgt Programs,Including Qualifications,Audits,Training, Radiation Protection Procedures & Instruments & Equipment IR 05000264/19830011983-04-29029 April 1983 Sanitized Version of Matl Control & Accounting Insp Rept 50-264/83-01 on 830405-06.No Noncompliance Noted.Major Areas Inspected:Facility Organization & Operation,Measurement & Statistical Control & Storage & Internal Controls IR 05000264/19810021982-01-11011 January 1982 IE Insp Repts 50-264/81-02 & 70-1487/81-01 on 811207-10. No Noncompliance Noted.Major Areas Inspected:Followup on IE Circulars,Lers & Open Insp Items & Review of Records,Logs & Organization IR 05000264/19810011981-01-23023 January 1981 IE Insp Rept 50-264/81-01 on 810112-14.No Noncompliance Noted.Major Areas Inspected:Records,Logs & Organization, Review & Audit Functions,Requalification Training, Surveillance & Maint & Experiments IR 05000264/19800021980-09-22022 September 1980 IE Insp Rept 50-264/80-02 on 800910-12.No Noncompliance Noted.Major Areas Inspected:Qualifications,Audits,Training, Radiation Protection Procedures,Instruments & Equipment Exposure Control IR 05000264/19800011980-09-15015 September 1980 IE Insp Rept 50-264/80-01 on 800828-29.No Noncompliance Noted.Major Areas Inspected:Emergency Planning,Facilities, Equipment,Drills & Training IR 05000264/19790031979-12-0303 December 1979 IE Insp Rept 50-264/79-03 on 791022-24.Noncompliance Noted: Failure to Perform Monthly Checklist in June ML19290C5631979-12-0303 December 1979 Notice of Violation from Insp on 791022-24 ML19210E5721979-10-22022 October 1979 IE Insp Rept 50-264/79-02 on 791002-03.Noncompliance Noted: Failure of Reactor Operations Committee to Meet Quarterly IR 05000264/19790011979-05-0303 May 1979 IE Insp Rept 50-264/79-01 on 790411-12.No Noncompliance Noted.Major Areas Inspected:Security Plan.Details Withheld (Ref 10CFR2.790) ML20249A9411979-01-16016 January 1979 PNS-78-004:inspectors from Region III Entered Research Reactor Bldg Through Unlocked Rear Door W/O Challenge on 780110-12.Ltr Was Sent to Licensee to Assure Institution of Positive Access Controls to Reactor Bldg IR 05000264/19780041978-12-27027 December 1978 IE Insp Rept 50-264/78-04 on 781116-17.No Noncompliance Noted.Major Areas Inspected:Special Nuclear Matl Control & Accountability Including Facility Organization & Operation Measurement & Controls,Inventory & Shipping IA-85-259, Notice of Violation from Insp on 780110-12.Portions Deleted (Ref 10CFR2.790)1978-07-12012 July 1978 Notice of Violation from Insp on 780110-12.Portions Deleted (Ref 10CFR2.790) ML20205E5731978-07-12012 July 1978 Notice of Violation from Insp on 780110-12.Portions Deleted (Ref 10CFR2.790) IR 05000264/19780011978-07-11011 July 1978 Insp Rept 50-264/78-01 on 780110-12.Noncompliance Noted Re Security Organization & Access Controls.Portions Deleted (Ref 10CFR2.790).Written Statement in Reply to Notice of Violation Encl IR 05000264/19780021978-06-0606 June 1978 Insp Rept 50-264/78-02 on 780503-04.No Noncompliance or Deviations Identified.Areas Inspected:Radwaste Mgt & Radiation Protection Program,Including Qualifications, Audits,Training,Equipment & Instruments ML20205E3561978-01-16016 January 1978 PNS-III-78-004:on 780110,during Physical Security Insp,Lack of Positive Access Controls to Reactor Bldg Discovered. Portions Deleted (Ref 10CFR2.790).Related Draft Documents Encl IR 05000264/19770031977-08-24024 August 1977 Insp Rept 50-264/77-03 on 770809-11.No Noncompliance or Deviations Identified.Areas Inspected:Emergency Planning, Including Review of Emergency Plan & Implementing Procedures & Interviews W/Licensee Personnel IR 05000264/19770021977-08-17017 August 1977 Insp Rept 50-264/77-02 on 770719-22,26 & 27.No Noncompliance Noted.Major Areas Inspected:Reactor Startup & Routine Operation IR 05000264/19770011977-05-11011 May 1977 Insp Rept 50-264/77-01 on 770425-26.No Noncompliance or Deviations Identified.Area Inspected:Facilities & Equipment, Organization,Training,Radiation Protection Procedures & Health Physics Instrumentation IR 05000264/19760031976-04-20020 April 1976 Insp Rept 50-264/76-03 on 760407.No Noncompliance Identified.Area Inspected:Radiation Protection & Radwaste Programs,Including Records,Procedures,Equipment Inventory & Interviews W/Personnel IR 05000264/19760011976-03-24024 March 1976 Matls & Safeguards Insp Rept 50-264/76-01 on 760303-04.No Noncompliance Noted.Major Areas Inspected:Physical Inventory & Verification,Review of SNM Records,Depletion Calculations, Matl Transaction Forms & Matl Status Repts ML20205E3111976-02-10010 February 1976 Notice of Violation from Physical Protection Insp on 760115-16.Portions Deleted IR 05000264/19750011975-10-15015 October 1975 Insp Rept 50-264/75-01 on 750922-24.No Noncompliance Noted. Major Areas Inspected:Reactor Operations,Maint, Implementation of Modified Operator Requalification Program & Corrective Action on Noncompliance Item 73-01 IR 05000264/19740011974-04-0202 April 1974 RO Insp Rept 50-264/74-01 on 740306 & 07.No Violations Noted.Areas Inspected:Personnel Monitoring,Surveys & Survey Instruments,Rabbit Sys,Radwaste,Area Radiation Monitor,Water Monitor & Continuous Air Monitor IR 05000264/19730011973-10-24024 October 1973 Insp Rept 50-264/73-01 on 730920 & 21.Violations Noted: Reactor Operated W/Greater than 1.5% Delta K/K Excess Reactivity on 730125 Change to Operating Procedure Inserted in Operating Log,W/O Formal Approval ML20137G6141971-06-22022 June 1971 Insp Rept 50-264/71-01 on 710602.No Deficiencies or Unresolved Items Found.Major Areas Inspected:Reporting Requirements Per 10CFR50.59 & Div of Compliance Procedures for Documentation,Records,Reactivity Control & Core Physics ML20136H1721971-06-0202 June 1971 Expanded Field Notes for Co Rept 50-264/71-01 on 710602. Areas Discussed:Administration & Organization Operations, Facility Procedures,Primary Sys,Reactor Controls & Core Physics,Functional Tests,Safety Circuitry & Core Internals ML20136H0411969-04-15015 April 1969 Co Insp Rept 50-264/69-01 on 690402.No Safety,Noncompliance or Unusual Occurrences Noted.Areas Inspected:Reactor Operation ML20137G9081968-10-17017 October 1968 Insp Rept 50-264/68-01 on 680926.No Noncompliance Noted. Major Areas Inspected:Visual Insp of Fuel Elements & Control ML20137G9261967-11-0707 November 1967 Insp Rept 50-264/67-03 on 671025-26.No Noncompliance Noted. Major Areas Inspected:Reviews of Reactor post-critical Performance Data & Appropriate Log Books,Observation of Startup & Discussions W/Personnel ML20137G4781967-07-14014 July 1967 Insp Rept 50-264/67-02 on 670630.No Safety Items or Noncompliance Noted.Major Areas Inspected:Completion of Unresolved Items Listed in App B to Insp Rept 50-264/67-01. Initial Criticality Observed During 670705-06 Visit ML20137G4171967-06-26026 June 1967 Insp Rept 50-264/67-01 on 670620 & 21.Deviations Noted: Manually Operated Louvres Installed as Backup to Automatic Louvres in Ventilation Intake & Exhaust Ducts & Reactor Room Area Monitor Placed on East Wall Rather than CRD Platform 1999-08-10
[Table view] |
Text
.
,
UNITED STATES Nt' CLEAR REGULATORY COMMIS510N OTTICE OT INSPECTION AND ENTORCEMENT
REGION III
IE Inspection Report No. 050-264/76-02 Licensee:
Dow Chemical Company Building 47 Midland, Michigan 48640 TRIGA Reactor License No. E-105 Midland, Michigan Category:
F Type of Licensee:
Research and Development Reactor Type of Inspection:
Materials, Safeguards - Unannounced Dates of Inspection: March 3 and 4, 1
'b 2*
b Principal Inspector *
A. G. Finley (Date)
gg
Accompanying Inspector *
D.
d
.
~(Date)
g Other Accompanying Personnel:
None
7h Reviewed By:
.A Hind, C Safeguards Branch (Date)
,
Attachment:
Findings (Part 2.790(d) Information)
S-F3-76-241 Copy j
of
Copies
.
Pages
!
THIS DOCUMENT IS NOT TO BE REPRODUCED WITHOUT SPECITIC APPROVAL OF IE:III i
i
.
0508220452 850724 PDR FOIA MOHNB5-256 PDR
,
,
w r
-
,
?
Part 2 7D3(d) Infor:stio=
-
.
SUMMARY OF FINDINGS
.
Inspection Summary Inspection conducted March 3 and 4, (76-02):
The inspection
-
consisted of a physical inventory and verification, review of special nuclear material records, depletion calculations, material transaction forms, and material status reports.
No items of noncompliance with NRC requirements were identified within the-scope of this inspection.
Enforcement Items None.
Licensee Action on Previously identified Enforcenent Items Not applicabic.
~
Other Significant Items A.
Systems and Components None.
.
B.
Facility items (Plans and Procedures)
'
On December 11, 1974, a timely request to renew License SSM-1451, due to expire January 31, 1975, was initiated by the Radiation Safety Officer to Directorate of Licensing.
A second inquiry was'made by teletex on February 26, 1976 to Directorate of Licensing requesting the renewal notification.
As of the inspection date, renewal notification for License SNM-1451 had not been received by the Dow Chemical Company.
C.
Managerial items L. C. Silverstein, Radiation Protection Officer, recently left the facility and C. W. Engdahl is presently Radiation Protection Officer at the Dow Chenical Company.
Effective January 1,1976 Mr. R. D. Deline replaced H. R. Hoyle as
Chairman of the Radiation Safety Committee.
D.
Noncompliance Identified and Corrected by Licensee
'
None.
2-
-
.
.
.
,
Part 2.790(d) Infor:ation
.
i.y./
'
I
.
.
Port 2.7'0(') Infer-St!C E.
Deviations None.
F.
Status of Previously Reported Unresolved Itees Not applicabic.
Manar<nent Interview
-
A management interview was conducted by Messrs. Finicy and Holody of the inspection tear with Mr. R. D. Deline, Chairear., Kadiation Safety Committee and R. A. Olson, Health Physicist.
The licensee was inforncd that no iters of noncompliance with NRC requirements were identified within the scope of this inspection.
It was also noted that as a result of NRC inspector depletion calculations for thc past 6.5 years, a small amount of depletion had occurred which would require reporting on the Material Status Report.
Since the recent Material Status Report for the period ending December 31, 1975, had to be revised because of a typographical error, it was suggested and agrewd, that the revised Material Status Report should also reflect on line 73 the few grams of depletion involved.
The licensee was also inf erred because they were not authorized to possess at any one time SNM in a quantity exceeding one effective kilogram they were exempt from the procedure requirements of 10 CFR 70.5) (c).
The inspectors, however, did indicate that even with thc lir.ited activity to date, it would appear to be good administrative practice to initiate procedures for the control, accountability and reporting of special nuclear material.
The chairman of the Reactor Saf ety Committee agreed to this and the inspectors Icft a list of pertinent 10 CFR 70 requirements as they pertain to a facility authorized to possess less than an effective kilogram of SNM.
The management interview terminated with the understanding that accountability and SNM control procedures would be established.
.
-3-
.
.
.
.
,
Tart 2,733(3) Infor-Stloa
-
& T*
i
.
.
.
Part 0.790(d) Infer:stice
REPORT DETAILS Licensee Personnel Supplying Information Dr. O. U. Anders, Reactor Supervisor G. W. Engdahl, Radiation Protection Officer R. A. Olson, Health Physicist
.
-Scone of Inspection The inspection was made to determine the If censee's compliance with the safeguards compliance of Title 10, Code of Federal Regulations, Part 70, as they pertain to a research and development reactor licensed ptrsuant to Part 50.
Facility Organization The licensee is not authorized to possess an effective kilogram of SNM and is exenpt from the 10 CFR 70.51(c) procedure requirement.
Annual serial, numbered physical _ inventorie,s are conduct,ed.
All and the fuel on hand
.is in the andlis u
only movement of SNM involves within movement documented in the reactor log book.
ICA or internal transfer movements are not applicable.
An up-to-date core diagram is maintained reflecting serial numbered fuel elements in each core position.
Physical annual inventories are maintained.
The Laboratory Director ackncwledges the receipt and shipment of all SNM.
The Reactor Supervisor is responsible for computation of uranium depletion, the Reactor Operations Committee for custody of SNM and investigation and reporting of accidental criticality.
loss or theft of SNM. The Radiation Protection Officer in
-
, conjunction with Health Physics is responsible f or the preparation of Forms NRC-741 and 742.
.
Facility Operation The primary use of the reactor is irradiating chemical samples for purposes of elemental analysis.
Percent element in sample is determined for chemical purposes for Dow in-house use.
The reactor is under the direct control of the Reactor Supervisor who is a licensed senior operator (LS0), with a staf f of one or more LSO's.
Samples to be irradiated and all experiments are
-
defined in a written request for reactor operation to be approved by the Reactor Supervisor.
For the first time a specific or type of experiment is conducted, approval by the Reactor Operations Committee is required.
-4-
.
'
.
.
.
Ta'rt 0.790(d) Inforestion
'
,
.
/
'
.
,
--
.'
P;rt 2.790(d) Inf or.stion
.
Reactor Operations Committee:
1.
Composed uf at least four menbers 'of the laboratory staff including Reactor Supervisor and qualified Health Physicist.
2.
Laboratory Director is Chairman.
3.
Shall establish written procedures regarding quorums, use of subcommittees, review of experiments and operations.
The commit tee will review:
_
a.
Experiments involving fissionable material.
b.
Experiments involving a change of core configuration, change in equipment or apparatus associated with the reactor core or its irradiation facilities, or a new piece of apparatus being mounted in the reactor well.
4.
Any other experiment, of a type not previously approved by the committee.
5.
The committee will approve proposed changes in operating procedures and be responsible for determining whether a proposed change, test or experiment would constitute an unreviewed safety question or a change in the specifications, as required by 10 CTR part 50 (50.59).
6.
The committee meets at least quarterly to review previous quarter operations and approve operations for the coming quarter.
In addition, the committee is available for determining safety or operational matters that are referred by the Reactor Supervisor or required by specifications.
7.
The Reactor Operations Committe; will report its operations
'
to the Radiation Hazards Committee, a subcommittee of the Executive Safety Coun'cil of the Dow Chemical Company.
The licensee has confined his possession and use of SNM to the location and purposes authorized by license as required by 10 CFR 70.41.
Measurements and Statistical Controls The licensee is operating the reactor at a maximum average of 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> a week at full power (100 kilowatts). At such a rate, the
inspector determined that there was some U-235 depletion, since
.
.$-
.
.
'
.
-
.
Part.2,790(d) Inforestion
.
,
~
.
w0
.
r
.
'
.
Port 3,790ld).Inforest the reactor has been in operation since July 6, 1967, a period of approximately 8.5 years.
The licensee agreed to a determination of
'
the depiction over the last 8.5 years and has agreed to make the adjustments on a revised Material Status Report for the period ending December 31, 1975.
- Shipping and Receiving Shipping and receiving has been a very Ifmited function to date and is accomplished by Radialf on protection in conjunction with Health physics.
The only receipts involvcJ the initial receipt of fuel in 1967 plus the receipt of two fiSFlon CounterF in 1967 and another in 1973.
The only external shipnents involved the return of 14 fuel assemblies not required in 1967 and one of the fission counters.
Forms AEC-388 and NRC-741 involved in the limited receipt and
-
shipment activity were' reviewed.
The forms were prepared and distributed as required by AEC-388 instructions and 10 CTR 70.54.
Storage and_ Internal Control The licensee has no ICA's or any necessity to initiate internal
transfer documents.
The;e is no spare fuel on hand and all fuel
,g
.is in the
~ '-
All within j
i core movements are documented by serial number and location in the reactor log book which is utilized to update the core schematic reflecting fuel element serial number and core locations.
Inventory and Inventory Verification The core at the Dow Research Reactor is circular in dimension,
with 91 positions availabl.e for fuel elements.
The core is divided into 6 regions which consist of the center and the 5 cylindrical strips surrounding the center.
The center has room f or 1 fuel element and the cylindrical strips have room for 6(X)
elements, where X=1 for the strip closest to the center and X-5 for the strip furthest from the center.
Thus, the six regions have respectively 1, 16, 12, 18, 24, and 30 positions available.
'
At present, there are fuel elements and
- dumny elements (these do not contain SNM) in the 91 core positions.
All 91 of these elements are 1.47 inches in diameter and 28.44 inches in
length.
The fuel elements are by weight eight percent uranium, 91 percent zirconium and I percent hydrogen, with an initial
.
-6-
.
.
Part 2.730(d) Inforestitt
-
,
-
.
.n
Part 2.790(d) Infor:2 tion
-
uranium-235 enrichment of 19.88 percent.
These fuel elenents are clad either with aluminum or stainless steel which is 0.30 inches thick, and they account for approximately 2.8 kilograms of uranium-235.
The dummy elements essentially are made of graphite.
The inspector verfiled the core by observing that all of the 91 posttions were filled and also by a random serial number verification of
.of the fuel elements.
This was achieved by having two Reactor Operators, under the supervision of the Reactor Supervisor, manually withdraw the fuel element from the core to a position about 5 or 6 feet below the surface of the water.
With the aid ol a, spotlight, the inspect 6r determined the serial number.
In all cases, the serial number and position matched the serial numbtr indicated for that element on the large status board in the reactor roon. The inventory also conristed of two fission counters which the inspector verified as being in the core.
This was the extent of the licensee's possession under License R-108.
The licensee also possesses two 30 millicurie Pu-238 sources and one 120 millicurie Pu-236 source under License No. SNM-1451 f or testing purposes.
The 120 millicurie Pu-238 source was physically verified and the two 30 millicurie sources verified by purchase order records.
Records and Reports The records review covered the period f rom the initial receipt of fuel in June 1967 through March 4, 1976.
There has been very limited activity and Material Status Reports since December 31, 1967 have been essentially unchanged.
A revision to the Material Status Report for the period ending December 31, 1975 was requested because of a typographical error and to report the first minor depletion since the 8.5 years of reactor operation as determined by the NRC inspectors.
The Dow Chemical Company has only a temporary storage rack utilized for within core movements and with all fuel in the reactor core and no extra fuel, ICA's and internal transfer documents are not established or dnitiated.
All within core movements are documented in the reactor log book which was checked and agreed to the current core schematic by serial number and location.
In June 1973 all material held under License No. R-108 was transferred from Icase to private on Form NRC YFX-YrX No. 1.
All transfers of SNM were restricted to authorized receivers as required by 10 CFR 70.42.
Forms NRC-741 and NRC-742 are prepared and distributed as required by 10 CFR 70.54 and 10 CFR 70.53, respectively.
'
-7-
.
Part 2.7J0(d) Inforestion
-
.
^ vfl
.
-
.,
Part 2.79D(d) Infor:aticn'*
The two 30 millicurie plutonium 238 sources and the one 120 millicurie plutonium 238 source authorized under License No. SNM-1451 are identified
,
by Dow Chemical Company purchase order numbers 910970-1, 911278-2 and 873018-1.
The 11censee's authorized limits and holdings as of March 5,1976 by docket and license are as follows:
Authorized Possession Docket Li c ens e Linit 3/5/76
,
=
50-264 R-108 3.4 kgs. U-235 70-1487 SNM-1451 270 millicuries Pu-238 gg[-
Exhibit A reficcts the activity for License R-108, Docket No. 50-264, f or the period of inspection and supports the possession values as of March 4, 1976.
-
There was no apparent loss or theft of special nuclear material that required reporting as required by 10 CTR 70.52.
The licensee's records system provides sufficient information to comply with all record requirements of 10 CTR 70.
Attachment:
Exhibit A
.
,
.
.
-8-Part 2.7s0(:) Information
.
-
.
,
O
--
_.]
l
'
.
.
.
.
Fort 2.790(d) Icfor:stio Dow Chemical Cormany - YFX Material Balance Statement - Privately Owned Enriched Uranium For Period 6/1/67 - 3/4/76 R-108 i
No. of Fuel Enriched Uranium Elements U
U-235
-
M Beginning Inventory 6/1/67 Receipts Total to Account For
.
.
.
Shipments
,
,
Depletion Ending Inventory 3/4/76 Total Accounted For km--
- - -
- - - - - - - - - -
. _ _ _ _ _ _
~ ' ~ -
1/
Includes material transferred from lease to private as a receipt.
2/
Includes material transferred from lease to private as a shipment.
Exhibit A
.
.
.
'
.
.
.
Part 2.790ld) Inforration
'
-
'
-
.
,