SUBJECT:
DOW CHEMICAL COMPANY - U.S. NUCLEAR REGULATORY COMMISSION ROUTINE INSPECTION REPORT NO. 05000264/2024201
Dear Dr. Yusuf:
From April 9-11, 2024, the U.S. Nuclear Regulatory Commission (NRC) staff conducted a routine inspection at the Dow TRIGA Research Reactor facility. The enclosed report documents the inspection results, which were discussed on April 11, 2024, with you, other members of management, members of the Reactor Operations Committee, and members of the reactor staff.
The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.
The inspector reviewed selected procedures and records, observed various activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified. No response to this letter is required.
In accordance with Title 10 of the Code of Federal Regulations Section 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
May 22, 2024 If you have any questions concerning this inspection, please contact Craig Bassett at (240) 535-1842, or by email at Craig.Bassett@nrc.gov.
Sincerely, Travis L. Tate, Chief Non-Power Production and Utilization Facility Oversight Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Docket No. 50-264 License No. R-108 Enclosure:
As stated cc: w/enclosure to GovDelivery Subscribers Signed by Tate, Travis on 05/22/24
NRC-002 OFFICE NRR/DANU/UNPO/PM NRR/DANU/UNPO/LA NRR/DANU/UNPO/BC NAME CBassett NParker TTate DATE 05/01/2024 05/01/2024 05/22/2024
Enclosure U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION Docket No.:
50-264 License No.:
R-108 Report No.:
05000264/2024201 Licensee:
Dow Chemical Company Facility:
Dow TRIGA Research Reactor Location:
Midland, Michigan Dates:
April 9-11, 2024 Inspector:
Craig Bassett Approved by:
Travis L. Tate, Chief Non-Power Production and Utilization Facility Oversight Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation
- 2 -
EXECUTIVE SUMMARY Dow Chemical Company Dow TRIGA Research Reactor Inspection Report No. 05000264/2024201 The primary focus of this routine, announced inspection of the Dow Chemical Company (Dow, the licensee) Class II research reactor facility was the onsite review of selected aspects of the safety programs including: (1) organization and staffing; (2) operations logs and records; (3) procedures; (4) requalification training; (5) surveillance and limiting conditions for operation (LCOs); (6) committees, audits and reviews; (7) maintenance logs and records; and (8) fuel handling logs and records. The U.S. Nuclear Regulatory Commission (NRC) staff determined that the licensees programs were acceptably directed toward the protection of public health and safety and in compliance with NRC requirements.
Organization and Staffing
The organization and staffing were in compliance with the requirements specified in the facility technical specifications (TSs).
Operations Logs and Records
Reactor operations logs and record keeping conformed to TS requirements.
Procedures
Written procedures were reviewed, approved, and implemented in accordance with TS requirements.
Requalification Training
Current operator requalification was conducted as required by the Dow requalification program and Title 10 of the Code of Federal Regulations (10 CFR) 55.59 Requalification.
Surveillance and Limiting Conditions for Operation
Surveillances were conducted and LCOs were maintained in accordance with TS requirements.
Committees, Audits and Reviews
The Reactor Operations Committee (ROC) provided the review and oversight required by the TSs.
Maintenance Logs and Records
Maintenance activities were conducted in accordance with licensee procedures.
Fuel Handling Logs and Records
Fuel handling and inspection activities were completed and documented as required by the TS and licensee procedures.
- 3 -
REPORT DETAILS Summary of Facility Status The licensee continued to operate the 300-kilowatt Mark I Training, Research, Isotopes, General Atomics (TRIGA) research reactor in support of research and development, reactor operator training, and periodic equipment surveillances. During the inspection, the reactor was operated in support of a reactor checkout.
1.
Organization and Staffing a.
Inspection Scope (Inspection Procedure (IP) 69001 - Section 02.01)
The inspector reviewed the following to verify compliance with the organization and staffing requirements specified in TS section 6.1:
organizational structure and staffing
staff qualifications and management responsibilities
reactor operations logbooks numbers (Nos.) 131 and 132
TSs for the Dow TRIGA Research Reactor (DTRR) dated June 18, 2014
DTRR annual reports for calendar years 2022 and 2023
various Dow Nuclear Research Reactor Procedures (DNRRP) including Nos. 3.2.1, 3.2.2, 3.2.7, and 3.2.8 b.
Observations and Findings Through document review and discussions with licensee staff, the inspector noted that the management structure at the facility remained the same as reported in the last NRC inspection report. The inspector confirmed that the reactor staff consisted of three individuals: the Facility Director/Reactor Supervisor (FD/RS), a senior research specialist, and a newly hired reactor operator trainee. The inspector found that the FD/RS and the research specialist maintained senior reactor operator (SRO) licenses at the facility. The inspector reviewed various records and verified that staffing was as required by TS section 6.1 and the licensees procedures.
c.
Conclusion The inspector determined that the licensees organization and staffing were in compliance with the requirements specified in the TSs.
2.
Operations Logs and Records a.
Inspection Scope (IP 69001 - Section 02.02)
The inspector reviewed the following to ensure that records were maintained as required by TS sections 3 and 4, and licensee procedural requirements:
scram logbook entries for the past 2 years
reactor operations logbooks Nos. 131 and 132
- 4 -
DTRR annual reports for the past 2 years
various DNRRP Procedures including Nos. 3.4, 3.5, 4.1, and 4.6 b.
Observations and Findings The inspector observed as an SRO completed a reactor pre-startup checkout, followed by a reactor startup to 5 watts. The inspector also observed that the reactor was then shutdown, and the key was removed and secured. Through a review of operations, the inspector confirmed that reactor operating characteristics and entries required by procedure were recorded in the reactor operations logbook. The inspector also confirmed that shift staffing met the minimum requirements for reactor operations.
The inspector reviewed the scram logbook and noted that, during the past 2 years, there were several scrams that occurred during the reactor startup sequence. Through discussions with the licensee the inspector found that most of the scrams resulted from an old computer processor which the licensee plans to replace as part of a future reactor console upgrade project.
c.
Conclusion The inspector determined that the licensees operational record keeping program conformed to TS requirements.
3.
Procedures a.
Inspection Scope (IP 69001 - Section 02.03)
The inspector reviewed the following to ensure that the requirements of TS section 6.4 were met:
procedural control, revision, and implementation
selected administrative and operations procedures
ROC semi-annual meeting minutes for the past 2 years
various DNRRP Procedures including Nos. 3.3, 4.1, 4.2, and 4.6 b.
Observations and Findings The inspector found that procedures were developed for the safe operation of the reactor as required by TS section 6.4. The inspector verified that procedure and experiment changes were reviewed and approved by the ROC as required by the TSs.
The inspector confirmed that training of personnel on procedures was completed as required by the licensees operator requalification program. The inspector also verified that licensee reactor operator personnel conducted operational activities in accordance with applicable procedures.
c.
Conclusion The inspector determined that procedural review, revision, approval, and implementation satisfied TS requirements.
- 5 -
4.
Requalification Training a.
Inspection Scope (IP 69001 - Section 02.04)
The inspector reviewed the following to verify compliance with the requirements in 10 CFR Part 55, Operators' Licenses, and the facility requalification program:
reactor operation logbooks Nos. 131 and 132
DTRR annual reports for the past 2 years
operator requalification program records for 2021 to the present
DTRR Requalification Program, approved by the NRC on September 6, 2011 b.
Observations and Findings The inspector noted that the licensees requalification program was as described in the plan submitted to the NRC and was in accordance with 10 CFR Part 55. The inspector found that the two facility SROs were completing the required written and operating examinations. The inspector verified that the licensed operators reviewed the emergency plan, security plan, and TSs on an annual basis. The inspector confirmed that the number of hours spent by each operator performing licensed duties were recorded in the operations logbook and that the SROs quarterly operating hours met the regulatory requirements. The inspector also verified that all operators licenses were current, and each received a physical examination biennially as required by the regulations.
c.
Conclusion The inspector determined that facility operator requalification was conducted as required by the DTRR requalification program and 10 CFR 55.59.
5.
Surveillance and Limiting Conditions for Operation a.
Inspection Scope (IP 69001 - Section 02.05)
The inspector reviewed the following to ensure that the surveillance requirements and LCOs specified in TS sections 3 and 4 were met:
reactor operation logbooks Nos. 131 and 132
surveillance data documented on various forms including the daily startup/shutdown checklists and forms 4.1.3a, 4.1.4, 4.1.5, 4.2.5b, and 4.3.4a, b, and c b.
Observations and Findings The inspector noted that daily, monthly, semi-annual, and annual surveillances of systems, as well as equipment checks, tests, and calibrations were completed as required by the TSs. The inspector confirmed that LCO verifications were completed on schedule and in accordance with licensee procedures. All the recorded results reviewed by the inspector were within the TS and procedurally prescribed parameter limits.
- 6 -
c.
Conclusion The inspector determined that the licensee's program for completing surveillance inspections and LCO confirmations satisfied TS requirements and procedural controls.
6.
Committees, Audits and Reviews a.
Inspection Scope (IP 69001 - Section 02.09)
The inspector reviewed the following to ensure that the audits and reviews stipulated in TS section 6.2 were completed by the ROC.
- RS semi-annual reports to the ROC
DTRR annual reports for the past 2 years
ROC semi-annual meeting minutes for the past 2 years
DNRRP Procedures Nos. 3.2 and 3.4 b.
Observations and Findings The inspector verified that the ROC met semi-annually and that a quorum was present as required by TS section 6.2.2. The inspector noted that the ROC minutes and the RS reports provided a record of ROC review functions and of their safety oversight of the reactor facility. The inspector confirmed that audits of the items required by TS 6.2.3 were completed, typically during annual peer review audits. The inspector confirmed that the safety reviews and audits, and the associated findings, were detailed and the licensee responded to the findings, if needed, and ensured that corrective actions were implemented.
c.
Conclusion The inspector determined that the review and oversight functions required by the TSs were completed by the ROC.
7.
Maintenance Logs and Records a.
Inspection Scope (IP 69001 - Section 02.11)
To ensure that maintenance activities were consistent with regulatory requirements, the inspector reviewed:
scram logbook entries for the past 2 years
reactor operations logbooks Nos. 131 and 132
DTRR annual reports for the past 2 years
DNRRP Procedures Nos. 3.4 and 4.5.3
completed maintenance forms 4.5.3.b for 2022 to the present b.
Observations and Findings The inspector confirmed that routine and preventive maintenance was controlled and documented on DTRR reactor maintenance forms. The inspector verified that, after all
- 7 -
maintenance was completed, item or system operational checks were performed to ensure the affected equipment and systems functioned properly before they were returned to service. The inspector also verified that implementation of changes to equipment, systems, tests, or experiments were reviewed by the ROC prior to completion by the reactor staff.
c.
Conclusion The inspector determined that maintenance activities were conducted in accordance with licensee procedures.
8.
Fuel Handling Logs and Records a.
Inspection Scope (IP 69001 - Section 02.12)
To verify that TS and procedural requirements were met, the inspector reviewed selected aspects of:
reactor operation logbooks Nos. 131 and 132
selected DNRRP Procedures including Nos. 4.3.2, 4.3.3, and 4.3.4 a b.
Observations and Findings The inspector verified that the licensee retained records of the various fuel movements and that the movements were conducted and recorded in compliance with licensee procedure. The inspector verified that a minimum of three operators were present when fuel was moved as required by procedure. The inspector confirmed that all fuel movements were documented in the reactor operations logbook, as well as on the fuel element position indicator map in the reactor room. The inspector verified that fuel element inspections included all the fuel elements every 5 years, and the reactivity worth of each control rod was measured on an annual frequency.
c.
Conclusion The inspector determined that fuel handling and control rod inspection activities were completed and documented as required by TS and licensee procedures.
9.
Exit Interview The inspector presented the inspection results to licensee management and staff at the conclusion of the inspection on April 11, 2024. The inspector described the areas inspected and discussed the inspection observations. The licensee acknowledged the findings presented and did not identify as proprietary any of the material provided to or reviewed by the inspector during the inspection.
Attachment PARTIAL LIST OF PERSONS CONTACTED Licensee S. Brockington Senior Delivery Leader, Dow Emergency Services and Security, Midland - Michigan Operation N. Goodman Senior Research Specialist and SRO R. Hobson 1602 Building Manager G. Martin Technology Leader, ETC L. Miller Manager, Dow Medical, Midland C. Steele Reactor Operator trainee T. Stockman DTRR Level 1 Manager, and Chair, ROC K. Wegener-Gave Site and Reactor Facility Radiation Safety Officer and ROC member Facility Director and Reactor Supervisor INSPECTION PROCEDURES USED IP 69001 Class II Research and Test Reactors ITEMS OPENED, CLOSED, AND DISCUSSED Opened: