Insp Repts 50-237/86-19 & 50-249/86-23 on 860630-0703.No Violations or Deviations Noted.Major Areas Inspected: Resolution of IE Bulletin 79-02, Pipe Support Baseplate Design Using Concrete Expansion Anchors
ML17199F849
Person / Time
Site: Dresden  
Issue date: 07/17/1986
From: Danielson D, Norton J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML17199F848 List:
References
50-237-86-19, 50-249-86-23, IEB-79-02, IEB-79-2, NUDOCS 8607230105
Download: ML17199F849 (4)


Text

  • /:'

. '

U.S. NUCLEAR REGULATORY COMMISSION REGION II I Reports No. 50-237/86019(DRS); 50-249/86023(DRS)

Docket Nos. 50-237; 50-249 Licensee:

Commonwealth Edison Company P.O. Box 767 Chicago, IL 60690 Facility Name:

Dresden Station, Units 2 and 3 Inspection At:

Dresden Site, Morris, IL Licenses No. DPR-19; DPR-25 Inspection Conducted:

June 30 through July 3, 1986 Inspector~. F. Norton Approved By:

D. H. Danielson, Chief Materials and Processes Section Inspection Summary Inspection on(_~~~l~_l_Q_!~I~~~~_il.!:l]y 3, 1986 (B~or!~-~~~_50-~llL860l21QB~ /86023 DRS, 7\\reas Inspected:

Routine unannounced inspection of the resolution of IE Bulletin 79-02 "Pipe Support Baseplate Design Using Concrete Expansion Anchors.

Results:

No violations or deviations were identifie i---- -

PDR ADOCK 05000237 G

PD.

  • ~£._-

DETAILS Persons Contacted Commonwealth Edison Compa~~_JCE~2l

  • D. Scott, Station Manager
  • M. Strait, Station Nuclear Engineering Division
  • D. Adam, Regulatory Assurance
  • R. Jeisy, Station Quality Assurance
  • R. Flessner, Services Superintendent U. S. Regulator1_i:om~issj~~

L. McGregor, Senior Resident Inspector

  • E. Hare, Resident Inspector
  • Denotes those present at the exit intervie.

Licensee Action on IE Bulletins (Closed) IE Bulletin No. 79-02 (237/79-02-BB; lB; 249/79-02-BB; lB):

IE Bulletin No. 79-02 "Pipe Support Baseplate Design/Construction Using Concrete Expansion Anchor Bolts." Background IE Bulletin 79-02 addresses the design and construction of pipe support baseplates with concrete expansion anchor The bulletin was issued March 3, 1979, and supplemental revisions were issued July 21, August 20, and November 8, 197 The primary purpose of the bulletin was to assure that licensees had appropriately considered baseplate flexibility and its potential effects on anchor load Testing Program (1)

Commonwealth Edison Company (CECo) committed to perform static, dynamic and relaxation testing of expansion anchors to verify that the static and dynamic characteristics and capacities of the anchors conform to IE Bulletin 79-0 (CECo letter Cordell Reed to J. G. Keppler dated July 5, 1979.) A summary report entitled, "Static, Dynamic and Relaxation Testing of Expansion Anchors in Responses to NRG IE Bulletin 79-02, 11 was issued July 20, 198 (2)

The purpose of the test program was to supplement previous responses which had referred to these tests. The specific items addressed by the tests were ultimate static capacities of various types of expansion anchors; load-displacement relation-ships for these anchors; behavior of expansion anchors subjected to simulated seismic events and other cyclic loads; baseplate flexibility and its effect on anchor loads; and the phenomenon of relaxation (loss of anchor preload) with tim.*

(3)

These tests were divided into four phases (A through D), and provided a clear understanding of anchor behavior under a wide range of static and dynamic loadings and the effect of various parameters on that behavio (a)

Phase A involved static tension tests of single anchors and provided an understanding of individual anchor behavior. This series of tests proved that the level of preloading of the anchor at the time of testing does not affect the ultimate capacity of the ancho (b)

In Phase B type tests, wedge, sleeve, and shell type anchored plate assemblies were cyclically loaded to simulate seismic or pipe transient type loadings. These tests were performed in reinforced concrete and concrete blocks walls, and confirmed that anchors embedded in concrete block and mortar can withstand cyclic load levels of at least 25% of the anchor ultimate static capacit Tests in reinforced concrete demonstrated that anchors could withstand cyclic loads up to 50% of the anchor ultimate static capacity. Also, it was determined that preload was not a determining factor as far as capacity of the anchor was concerne (c)

Phase C tests were static tests on anchored baseplate assemblies for purposes of determining the effects of prying action on flexible plate The results of these tests revealed that prying action is in the order of 15%

to 20% of the applied load. This increase was lower than originally anticipated due to lower stiffness modulus of expansion anchors installed in concret (d)

Phase D tests were run to determine the amount of relaxa-tion of load that occurs in an anchor after it has been preloade After the cyclic tests were completed, which demonstrated that preload is not required to withstand cyclic loading, it was subsequently determined that the relaxation phenomenon is not of significant concer (4) A major finding resulting form the testing is that loss of preloading in an anchor does not affect the static ultimate load capacity of the anchor, nor is preload required for an anchor to withstand cyclic loading (5)

The licensee field tested anchor installations at Dresden Station as follows:

Load Test 1208 tested 9 failures Thread Engagement 1120 tested 6 failures Shell Projection 1128 tested 3 failures Angularity 1805 tested 77 failures This data represents a 95% confidence level. This is consistent with CECo's commitments to the NRC regarding the 1195-5 11 criteria

~

jl,"- ':' : **

presented in D. L. Peoples letter to J. G. Keppler, dated February 19, 198 Conclusion All expansion anchors which did not meet inspection criteria were modified or replace Modifications were accomplished in accordance with licensee engineering and QA/QC requirement The NRC inspector reviewed quality records on several of the anchor installation No QA/QC deficiencies were discerne The NRC inspector, based on this review concluded that the actions set forth in IE Bulletin 79-02 have been complied with for Dresden Station, Units 2 and.

Exit Meeting The inspector met with licensee representatives (denoted under Persons Contacted) at the conclusion of the inspection on July 3, 198 The inspector summarized the purpose and findings of the inspectio The licensee acknowledged the findings as reported herei The inspector also discussed the likely informational content of the inspectors report with regard to documents or processes reviewed by the inspector during the inspectio The licensee did not identify any such documents/

processes as proprietar