05000400/LER-2016-001, Regarding Inadequate Protection from Tornado Missiles Identified Due to Nonconforming Design Conditions

From kanterella
(Redirected from 05000400/LER-2016-001)
Jump to navigation Jump to search
Regarding Inadequate Protection from Tornado Missiles Identified Due to Nonconforming Design Conditions
ML16245A804
Person / Time
Site: Harris 
(NPF-063)
Issue date: 09/01/2016
From: Waldrep B
Duke Energy Progress
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
HNP-16-065 LER 16-001-00
Download: ML16245A804 (6)


LER-2016-001, Regarding Inadequate Protection from Tornado Missiles Identified Due to Nonconforming Design Conditions
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(x)
4002016001R00 - NRC Website

text

(~ DUKE ENERGY.

SEP 01 2016 Serial: HNP-16-065 A TIN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Shearon Harris Nuclear Power Plant, Unit 1 Docket No. 50-400/Renewed License No. NPF-63 Subject: Licensee Event Report 2016-001-00 Ladies and Gentlemen:

Benjamin C. Waldrep Vice President Harris Nuclear Plant 5413 Shearon Harris Road New Hill NC 27562-9300 919.362.2502 10 CFR 50.73 Duke Energy Progress, Inc., submits the enclosed Licensee Event Report 2016-001-00 in accordance with 10 CFR 50. 73 for Shearon Harris Nuclear Power Plant, Unit 1. This report details nonconformances associated with protection against potential tornado missile impact.

This document contains no regulatory commitments. Please refer any questions regarding this submittal to John Caves at (919) 362-2406.

Sincerely, Enclosure: Licensee Event Report 2016-001-00 cc:

Mr. M. J. Riches, NRC Sr. Resident Inspector, HNP Ms. M. Barillas, NRC Project Manager, HNP Regional Administrator, Region II

Benjamin C. Waldrep Vice President Harris Nuclear Plant 5413 Shearon Harris Road New Hill NC 27562-9300 919.362.2502 10 CFR 50.73 Serial: HNP-16-065 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Shearon Harris Nuclear Power Plant, Unit 1 Docket No. 50-400/Renewed License No. NPF-63 Subject: Licensee Event Report 2016-001-00 Ladies and Gentlemen:

Duke Energy Progress, Inc., submits the enclosed Licensee Event Report 2016-001-00 in accordance with 10 CFR 50.73 for Shearon Harris Nuclear Power Plant, Unit 1. This report details nonconformances associated with protection against potential tornado missile impact.

This document contains no regulatory commitments. Please refer any questions regarding this submittal to John Caves at (919) 362-2406.

Sincerely, Benjamin C. Waldrep Enclosure: Licensee Event Report 2016-001-00 cc:

Mr. M. J. Riches, NRC Sr. Resident Inspector, HNP Ms. M. Barillas, NRC Project Manager, HNP Regional Administrator, Region II

LICENSEE EVENT REPORT (LER)

NRC FORM 366 (06-2016)

U.S. NUCLEAR REGULATORY COMMISSION Estimated burden per response to comply with this mandatory collection request: 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br />.

Reported lessons learned are incorporated into the licensing process and fed back to industry.

Send comments regarding burden estimate to the FOIA, Privacy and Information Collections Branch (T-5 F53), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by e-mail to Infocollects.Resource@nrc.gov, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0104), Office of Management and Budget, Washington, DC 20503. If a means used to impose an information collection does not display a currently valid OMB control number, the NRC may not conduct or sponsor, and a person is not required to respond to, the information collection.

APPROVED BY OMB: NO. 3150-0104 EXPIRES: 10/31/2018 (See Page 2 for required number of digits/characters for each block) 1 OF

3. PAGE 05000
4. TITLE
5. EVENT DATE
6. LER NUMBER
7. REPORT DATE
8. OTHER FACILITIES INVOLVED MONTH DAY YEAR SEQUENTIAL NUMBER REV NO.

FACILITY NAME 05000 DOCKET NUMBER FACILITY NAME 05000 DOCKET NUMBER

9. OPERATING MODE
10. POWER LEVEL
11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR §: (Check all that apply)
12. LICENSEE CONTACT FOR THIS LER LICENSEE CONTACT TELEPHONE NUMBER (Include Area Code) CAUSE SYSTEM COMPONENT MANU-FACTURER REPORTABLE TO EPIX

CAUSE

SYSTEM COMPONENT MANU-FACTURER REPORTABLE TO EPIX

14. SUPPLEMENTAL REPORT EXPECTED YES (If yes, complete 15. EXPECTED SUBMISSION DATE)

NO

15. EXPECTED SUBMISSION DATE YEAR DAY MONTH ABSTRACT (Limit to 1400 spaces, i.e., approximately 15 single-spaced typewritten lines)

NRC FORM 366 (06-2016)

YEAR YEAR DAY MONTH 20.2201(b) 20.2203(a)(3)(i) 50.73(a)(2)(vii) 20.2203(a)(2)(ii) 20.2203(a)(2)(i) 20.2203(a)(1) 20.2201(d) 20.2203(a)(2)(iii) 20.2203(a)(2)(iv) 20.2203(a)(2)(v) 20.2203(a)(2)(vi) 20.2203(a)(3)(ii) 20.2203(a)(4) 50.36(c)(1)(i)(A) 50.36(c)(1)(ii)(A) 50.36(c)(2) 50.46(a)(3)(ii) 50.73(a)(2)(i)(A) 50.73(a)(2)(i)(B) 50.73(a)(2)(ii)(A) 50.73(a)(2)(ii)(B) 50.73(a)(2)(iii) 50.73(a)(2)(iv)(A) 50.73(a)(2)(v)(A) 50.73(a)(2)(v)(B) 50.73(a)(2)(v)(C) 50.73(a)(2)(v)(D) 50.73(a)(2)(viii)(A) 50.73(a)(2)(viii)(B) 50.73(a)(2)(ix)(A) 50.73(a)(2)(x) 73.71(a)(4) 73.71(a)(5)

OTHER Specify in Abstract below or in Page of 05000-

3. LER NUMBER YEAR SEQUENTIAL NUMBER REV NO.

E. Corrective Actions

Corrective Actions Completed:

o Verified that procedures are in place and training is current for actions to be taken if a tornado watch or warning is issued for the area, and for performing actions in response to a tornado.

o Established a heightened level of station awareness and preparedness relative to identified tornado missile vulnerabilities.

  • Implemented comprehensive compensatory measures that demonstrated a discernable change from pre-discovery conditions as described in EGM 15-002.
  • Revised the plant Severe Weather Response procedure to include actions specific to the identified tornado missile vulnerabilities that include pre-tornado walkdowns to reduce the possibility of a tornado-generated missile and post-tornado walkdowns to expedite the identification and restoration of the vulnerable equipment if affected by a tornado-generated missile. Suggested actions to restore functionality of the affected equipment have been included in the procedure.

Corrective Actions Planned:

  • Establish compliance by either engineering and installing a plant modification or by employing a methodology for addressing tornado missile noncompliances acceptable to the NRC.

F. Previous Occurrences

There have been no previous Licensee Event Reports at Harris on this issue.

G. Component Failure: None.

4 4

Shearon Harris Nuclear Power Plant - Unit 1 400 2016 001 00