05000361/LER-1982-006, Forwards LER 82-006/99X-0.Detailed Event Analysis Submitted

From kanterella
Jump to navigation Jump to search
Forwards LER 82-006/99X-0.Detailed Event Analysis Submitted
ML20054E085
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 04/16/1982
From: Ray H
SOUTHERN CALIFORNIA EDISON CO.
To: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
Shared Package
ML20054E086 List:
References
NUDOCS 8204260117
Download: ML20054E085 (2)


LER-1982-006, Forwards LER 82-006/99X-0.Detailed Event Analysis Submitted
Event date:
Report date:
3611982006R00 - NRC Website

text

O o.

6,_

NET 9

@ e.,

Southern California Edison Company o

n.

S AN ONC F RE NUC L E AR GE NER A TING S T A TION

/

P.O. E9 0 4 128 L

SAN C LEVE N T E. C A bt F OR NI A 92672 H8*

,, a t... o,

57AftOMMANAGER

' ( P l / 0,/

April 16,1982 9

XG s -

W a.

.c b

b [o' <(.!, ~

U.S. Nuclear Regulatory Commission

,f]/

Office of Inspection and Enforcement Region V p p.

A/

1450 Maria Lane, Suite 210 yp' Walnut Creek, CA 94596-5368 cv Docket No. 50-361 Licensee Event Report 82-006 San Onofre-Unit 2 Attention: Mr. R. H. Engelken, Regional Administrator

Dear Mr. Engelken:

In our letter to you dated March 30, 1982, forwarding Licensee Event Reports (LER)82-002 and 82-003, we indicated that a separate LER, addressing the inconsistency in Refueling Water Storage Tank (RWST) boron concentrations, would be submitted within 30 days of the event for information.

Attached is LER 82-006, reporting for information only, the stratifi-cation which bad occurred in the SONGS Unit 2 RWST. Due to this stratification, RWST boron concentration samples were not representative of tank contents and consequently contributed to the unplanned positive reactivity addition reported in LER 82-003.

It must be noted that the borated water source and flow path required by Technical Specification LC0's 3.1.2.1 and 3.1.2.7 was being satisfied by the Boric Acid Makeup Tanks and Boric Acid Pumps and not the RWST which was isolated, except during recovery from the loss of shutdown cooling event, during this period.

The following is a summary of the operations and events resulting in discovery of the stratification problem.

On February 24, 1982, Operations personnel began filling Refueling Water Storage Tanks T005 and T006. The tanks were first filled to the 15%

level with unborated water, and then, subsequently, filled to 25% with batches of water borated to 3000 ppm.

On March 6,1982, the two RWST's were separated by closing their cross-connect pipe, and borated water, at 2000 ppm, was batched into T006 causing its level to rise to about 85%.

- 8204260ljy f Mg

8 o

. As a result of the Loss of Shutdown Cooling Event on March 14, 1982 (see LER's82-002 and 003), several thousand gallons of water were pumped from T006 into the RCS and T005. Boron samples from the bottom of T006 prior to the event indicated about 2000 ppm. Since the RCS dilution was greater than expected for this boron concentration, T006 samples were taken at various elevations within the tank. These sample results showed concentrations of 612 ppm at the top,1490 ppm in the middle, and 1501 ppm at the bottom.

The stratification found in T006 is attributed to the inability to mix the tank in its isolated condition. All additions to and removals from T006 are made from the bottom of the tank.

For this reason, the original unborated water in T006 was never adequately mixed with the subsequent borated water additions. T005, on the other hand, has water returned at the top of the tank and did not experience this stratification.

On March 19,1982,'both T005 and T006 were recirculated. As a part of this recirculation, a temporary line was installed, which drew from the bottom of T006 and returned to the top. This effectively removed the stratification in T006.

Operating instructions have been revised to provide for recirculation of RWST-T006 using a temporary system taking suction from the bottom of T-006 and discharging to the top.

Permanent modification to ensure adequate mixing in T006 is presently scheduled for completion before December 31, 1982.

Should you require further information, please contact me.