05000348/FIN-2014005-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Ensure Rolling Fire Doors on Units 1 and 2 Complied with Fire Code |
| Description | An NRC-identified non-cited violation (NCV) of Farley Nuclear Plant, Unit 1, Operating License Condition 2.C.(4), and Unit 2, Operating License Condition 2.C.(6), Fire Protection was identified. The installed rolling steel fire doors design did not include fire detectors (fusible links or other type of labeled fire detection devices) to automatically close the doors in the event of a fire in Fire Area 71 (South Hallway). The licensee included this deficiency in their corrective action program (CAP) as CR867970 and implemented an hourly fire watch in the affected Fire Areas. The licensees failure to ensure that rolling steel fire doors included fire detectors to automatically close the doors under fire conditions, in the event of a fire in Fire Area 71 (South Hallway), was a performance deficiency (PD). The PD was more than minor because it was associated with the Protection Against External Events (Fire) attribute of the Mitigating Systems cornerstone and it adversely affected the cornerstone objective in that a fire in the common hallway could propagate into the individual EDG compartments. This finding is of very low safety significance. There is no cross-cutting aspect for this deficiency because the problem was not indicative of current licensee performance. |
| Site: | Farley |
|---|---|
| Report | IR 05000348/2014005 Section 4OA2 |
| Date counted | Dec 31, 2014 (2014Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | W Pursley A Vargas B Caballero C Dykes D Mas J Montgomery K Miller M Coursey M Franke P Niebaum R Kellner W Loo |
| Violation of: | License Condition - Fire Protection License Condition |
| INPO aspect | |
| ' | |
Finding - Farley - IR 05000348/2014005 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Farley) @ 2014Q4
Self-Identified List (Farley)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||