Finding | |
|---|---|
| Title | Failure to Identify and Correct Nuclear Service Water Pump Shaft Degradation |
| Description | An NRC identified Green non-cited violation (NCV) of 10 CFR 50, Appendix B, Criterion XVI, Corrective Action, was identified for the failure of the licensee to identify and correct a condition adverse to quality (CAQ) on the 1B nuclear service water pump (NSWP). Specifically, between June 26, 2012, and January 12, 2013, the licensee failed to identify or correct the pump shaft degradation on the 1B Nuclear Service Water Pump (NSWP) pump. This resulted in the shaft bearing delaminating and bearing material becoming dislodged and trapped in the pump strainer which caused the 1B NSWP to become inoperable. The licensee replaced the pump shaft and returned the pump to operable. The licensee entered this issue into the corrective action program (CAP) as nuclear condition report (NCR) 582584. The inspectors determined that the failure of the licensee to identify and correct the 1B NSWP shaft degradation before the pump failed was a performance deficiency. The finding was more than minor because it was associated with the equipment performance attribute of the Mitigating Systems Cornerstone and affects the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the shaft degradation resulted in the 1B NSWP being inoperable. Using IMC 0609, Appendix A, issued June 19, 2012, the SDP for Findings At-Power, the inspectors determined the finding was of very low safety significance (Green) because the finding did not affect the design or qualification of a mitigating structure, system and component (SSC), the finding did not represent a loss of system and/or function, the finding did not represent an actual loss of a function of a single train for greater than the technical specifications (TS) allowed outage time, the finding did not represent an actual loss of a function of one or more non-TS trains of equipment, and did not screen as potentially risk-significant due to a seismic, flooding, or severe weather initiating event. The finding has a cross-cutting aspect in the area of problem identification and resolution associated with the CAP attribute because the licensee failed to implement a CAP with a low threshold for identifying issues, specifically the licensee did not enter this issue into the CAP in June 2012. |
| Site: | Brunswick |
|---|---|
| Report | IR 05000324/2013004 Section 1R15 |
| Date counted | Sep 30, 2013 (2013Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.15 |
| Inspectors (proximate) | M Speck N Staples S Sanchez A Nielsen G Hopper J Austin J Zeiler M Catts M Schwieg |
| Violation of: | 10 CFR 50 Appendix B Criterion XVI Technical Specification |
| CCA | P.1, Identification |
| INPO aspect | PI.1 |
| ' | |