Finding | |
|---|---|
| Title | Residual Heat Removal A Heat Exchanger Bypass Valve 2-E11-F048A Stud Failure |
| Description | The inspectors are opening an URI to review the licensees evaluation of the operability of A RHR heat exchanger bypass valve 2-E11-F048A and determine if the performance deficiency associated with this issue is more than minor. On March 29, 2012, during Unit 2 refueling outage B221R1, maintenance personnel were going to repack A RHR heat exchanger bypass valve 2-E11-F048A. A member of maintenance hit one of the four valve yoke to bonnet hold down 134 studs with his foot and the stud sheared off at the nut. A second yoke hold down stud sheared off at the nut when maintenance personnel tried to remove the nut. The licensees corrective actions included replacing the four studs. The licensee determined the failure mechanism of the two studs was low stress, high cycle fatigue caused by vibration of the valve during throttling operations. The inspectors determined that the performance deficiency associated with this issue was the failure of the licensee to evaluate the effects of vibration on valve 2-E11-F048A when the valve was used for throttling, which resulted in the two studs sheering. The inspectors are opening an URI to review the licensees evaluation of the operability of valve F048A and determine if the performance deficiency is more than minor. The licensee entered this issue in the CAP as NCR 598294. This issue is being tracked as a URI: URI 05000324/2013003-09, Residual Heat Removal A Heat Exchanger Bypass Valve 2-E11-F048A Stud Failure. |
| Site: | Brunswick |
|---|---|
| Report | IR 05000324/2013003 Section 1R19 |
| Date counted | Jun 30, 2013 (2013Q2) |
| Type: | URI: |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.19 |
| Inspectors (proximate) | E Stamm G Ottenberg G Skinner J Eargle M Catts M Riley M Yeminy N Coovert R Neasem Cattsm Schwieg R Taylor G Hopper J Dodson |
| INPO aspect | |
| ' | |
Finding - Brunswick - IR 05000324/2013003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Brunswick) @ 2013Q2
Self-Identified List (Brunswick)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||