Finding | |
---|---|
Title | Flood Impacts Due to Degraded Flood Protection Measures |
Description | The inspectors are opening a URI associated with the potential for flood intrusion into the service water building, reactor building, and emergency diesel generator building due to degraded flood protection measures to determine if a performance deficiency exists. From August through October, 2012, the licensee performed walkdowns of flood protection measures in accordance with Nuclear Energy Institutes 12-07 Walkdown Guidance. The licensee and inspectors identified degraded or missing flood protection measures in the service water building, reactor building, and emergency diesel generator building. The inspectors are opening a URI to review the licensees evaluation of these flood protection deficiencies and determine if a performance deficiency exists. The licensee entered these issues into the CAP as NCR 600850. This issue is being tracked as: URI 05000325/2013002-02 and 05000324/2013002-02, Flood Impacts due to Degraded Flood Protection Measures. |
Site: | Brunswick ![]() |
---|---|
Report | IR 05000324/2013002 Section 4OA5 |
Date counted | Mar 31, 2013 (2013Q1) |
Type: | URI: |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | |
Inspectors (proximate) | M Catts M Schwieg G Hoppera Nielsenc Dykes J Worosilo L Lake M Catts M Schwieg R Musser W Pursley |
INPO aspect | |
' | |