05000282/FIN-2011012-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Correct a Condition Adverse to Quality |
Description | The inspectors identified a finding of very low safety significance and an associated NCV of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, for the licensee s failure to promptly correct a condition adverse to quality. Specifically, the licensee failed to submit a license amendment request (LAR) to correct the non-conservative Technical Specification (TS) surveillance requirements in Section 3.8.1 for the emergency diesel generators (EDGs) allowable steady state frequency. The issue was originally identified and entered into the licensee s corrective action program on September 8, 2006. During this inspection, the licensee entered the finding into their corrective action program to evaluate how to resolve the issue. The inspectors determined that the finding was more than minor because the finding was associated with the Mitigating Systems cornerstone s attribute of Equipment Performance and affected the cornerstone s objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). Specifically, the licensee could not be assured that the design requirements for the EDGs system loads would operate within the appropriate design specifications if the EDGs were allowed to operate within the non-conservative TS allowable steady state frequency of Y 58.8 Hertz (Hz) and U 61.2 Hz. As a result, the licensee established an administrative limit to limit operation of the EDGs to a frequency between 59.5 Hz and 60.5 Hz. The finding was of very low safety significance because it did not result in a loss of operability. The finding had a cross-cutting aspect in the area of human performance, decision-making because the licensee repeatedly delayed submitting the license amendment until a resolution was developed by an industry working group. |
Site: | Prairie Island |
---|---|
Report | IR 05000282/2011012 Section 4OA2 |
Date counted | Dec 31, 2011 (2011Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | J Gilliam R Daley D Szwarc G Hausman |
CCA | H.13, Consistent Process |
INPO aspect | DM.1 |
' | |
Finding - Prairie Island - IR 05000282/2011012 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2011Q4
Self-Identified List (Prairie Island)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||