Finding | |
|---|---|
| Title | Potential Maintenance Rule Scoping Issue for Residual Heat Removal Pump Pit Sump Pumps and Level Switches |
| Description | The inspectors identified a URI regarding the need to include the residual heat removal (RHR) pump pit sump pumps and level switches within the scope of the licensees maintenance rule program. Description: During a review of daily corrective action documents, the inspectors noted several documents which questioned the safety classification of the sump pumps and level switches located in the RHR pump pits. The sump pumps and level switches were used to remove water from the pits that may accumulate due to system leakage. Based upon the information in these corrective action documents, the inspectors selected the sump pumps and level switches (which were considered part of the waste liquid system) for additional review. The inspectors reviewed information contained within the licensees computer database and determined that the sump pumps and level switches were functionally checked every three years. The inspectors reviewed the maintenance history and determined that the functional checks were performed within the required periodicity. The inspectors reviewed the licensees Maintenance Rule Bases Document to determine whether the waste liquid systems risk-significant functions had been properly scoped into the maintenance rule. Title 10 CFR Part 50.65 required licensees to include equipment whose failure could prevent safety-related SSCs from fulfilling their safety function as part of their maintenance rule program. The inspectors noted that the RHR pump pit sump pumps and level switches were not included in the licensees maintenance rule program even though the failure of this equipment during an RHR pump pit internal flood may prevent the RHR system (a safety-related system) from fulfilling its safety function. As a result, the inspectors were concerned that the licensee may not be monitoring the performance of the sump pumps and level switches as required by the NRC. The inspectors discussed their concern with maintenance rule and system engineering personnel. At the conclusion of the inspection, the licensee was reviewing licensing and design basis information to determine whether the RHR pump pit sump pumps and level switches were credited as part of the internal flooding analysis. The inspectors planned to review the licensees results when they were available to aid in determining whether the licensee was in compliance with 10 CFR Part 50.65. As a result, this issue was determined to be unresolved pending the inspectors\\\' review of the licensees licensing and design basis information |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000306/2011005 Section 1R12 |
| Date counted | Dec 31, 2011 (2011Q4) |
| Type: | URI: |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.12 |
| Inspectors (proximate) | C Moore C Thomas D Passehl D Szwarc J Beavers J Jandovitz K Riemer K Stoedter M Phalen P Zurawski R Langstaff V Myers A Dunlop A Shaikhr Bakers Bell D Mcneil D Oliver K Riemer K Stoedter M Phalen P Voss P Zurawski |
| INPO aspect | |
| ' | |