05000306/FIN-2011005-04
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Complete Immediate Operability Determination on Molded Case Circuit Breakers |
| Description | A finding of very low safety significance and an associated NCV of 10 CFR Part 50, Appendix B, Criterion V, was identified by the inspectors due to the licensees failure to complete an immediate operability determination as required by Procedure FP-OP-OL-01, Operability/Functionality Determination. On October 27, 2011, the licensee identified that numerous molded case circuit breakers may not have received appropriate testing to demonstrate that the breakers would open to protect safety-related equipment. Although a corrective action document was written, an immediate operability determination was not performed because the information in the document was viewed as programmatic in nature. Corrective actions for this event included performing the immediate operability determination and ensuring that operations personnel understood that operability determinations were required for programmatic concerns which questioned equipment operability. The inspectors determined that this issue was more than minor because, if left uncorrected, the failure to complete operability determinations could result in leaving inoperable plant equipment in service (a more significant safety concern). The inspectors determined that this issue was of very low safety significance because it was not a design deficiency; it did not represent a loss of system safety function; it did not present a loss of safety function for one train for greater than the Technical Specification (TS) allowed outage time; and it did not screen as potentially risk significant due to a seismic, flooding or severe weather initiating event. This finding was determined to be cross-cutting in the Human Performance, Decision Making area because the licensee failed to use conservative assumptions when deciding whether an immediate operability determination was needed for the molded case circuit breakers (H.1(b)). |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000306/2011005 Section 1R15 |
| Date counted | Dec 31, 2011 (2011Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.15 |
| Inspectors (proximate) | R Baker S Bell D Mcneil D Oliver K Riemer K Stoedter M Phalen P Voss P Zurawski |
| CCA | H.14, Conservative Bias |
| INPO aspect | DM.2 |
| ' | |
Finding - Prairie Island - IR 05000306/2011005 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2011Q4
Self-Identified List (Prairie Island)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||