Finding | |
|---|---|
| Title | Potential Safety System Functional Failure Due to Steam Exclusion Damper Issues |
| Description | At the Prairie Island Nuclear Generating Plant, certain ventilation systems were designed with steam exclusion dampers. These dampers automatically closed during high energy line break (HELB) events to ensure that safety-related equipment remained protected from the impacts of high temperature steam. On August 24, 2011, steam exclusion control damper (CD) 34197 failed to fully close during surveillance testing. The licensee entered the appropriate Technical Requirements Manual (TRM) Action Statement, which directed that the redundant damper be closed within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The inspectors verified that the redundant damper was closed within the required time. The inspectors observed the licensees repair and PM testing of CD-34197 to ensure that the damper was properly returned to service. On September 21, 2011, the licensee tested CD-34187 and CD-34188 which were used to protect equipment located on the 695 foot elevation of the auxiliary building from a HELB. During this testing CD-34187 closed, but gaps were identified between several damper blades. The licensee documented this condition in CAP 1304753. The inspectors verified that the licensee entered the appropriate TRM Action Statement and that the redundant damper (CD-34188) was closed within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. While performing maintenance activities on CD-34187 on September 22, 2011, the licensee identified that the blades of damper CD-34188 also contained gaps. As a result, the licensee could not credit the closure of CD-34188 to meet the TRM Action Statement. The licensee immediately installed a blind flange to ensure that safety-related equipment remained protected from a HELB event. The licensee documented this condition in CAP 1305151. Since both dampers contained gaps, the inspectors were concerned that the condition of the dampers could have constituted a safety system functional failure or could have resulted in an unintended safety system functional failure of equipment located in the auxiliary building. The licensee was continuing to review the inspectors concerns at the conclusion of the inspection period. As a result, this item will remain unresolved pending a review of documentation evaluating whether the safety-related equipment remained protected from HELBs even though both dampers contained gaps |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000306/2011005 Section 3S03 |
| Date counted | Dec 31, 2011 (2011Q4) |
| Type: | URI: |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71130.03 |
| Inspectors (proximate) | C Moore C Thomas D Passehl D Szwarc J Beavers J Jandovitz K Riemer K Stoedter M Phalen P Zurawski R Langstaff V Myers A Dunlop A Shaikhr Bakers Bell D Mcneil D Oliver K Riemer K Stoedter M Phalen P Voss P Zurawski |
| INPO aspect | |
| ' | |
Finding - Prairie Island - IR 05000306/2011005 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2011Q4
Self-Identified List (Prairie Island)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||