Finding | |
|---|---|
| Title | Failure to Manage Emergent Risk Condition during A1 and A2 RHRSW Inoperability |
| Description | The team identified a self-revealing, Green non-cited violation (NCV) of 10 CFR 50.65 (a)(4), Requirements for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants, due to BFNs failure to adequately manage the impact of an emergent risk condition related to the A1 residual heat removal service water (RHRSW) quarterly surveillance test. BFN recognized the online maintenance risk condition however, failed to implement appropriate risk management actions (RMAs) in accordance with Procedure BFN-ODM-4.18, Protected Equipment. The A and B emergency diesel generators were required to be protected. BFN entered this issue into their corrective action program (CAP) as SR 730356. Specifically, on May 6, 2013, with the A2 RHRSW pump inoperable for planned maintenance, the A1 RHRSW pump was declared inoperable during the A1 RHRSW pump quarterly test due to a tagging error that resulted in Assistant Unit Operators closing and danger tagging the A1 pump manual discharge valve instead of the required A2 pump discharge valve. Upon starting the A1 RHRSW pump, control room alarms provided the operators indication of a system problem, and in the course of responding to the alarm, the operators noted the danger tag. The tags were removed and the pump was declared inoperable to fill and vent the system prior to returning it to an operable status. This issue was entered in to the corrective action program as PER 722859 and 731570. The team determined that BFNs failure to adequately manage the impact of an emergent risk condition related to the A1 residual heat removal service water (RHRSW) quarterly surveillance test was a performance deficiency that was reasonably within BFNs ability to foresee and correct. The performance deficiency was determined to be more than minor and a Finding because, if the deficiency was left uncorrected, it had the potential to lead to a more significant safety concern. Specifically, the failure to take adequate RMAs could have led to unplanned inoperability of redundant TS or risk significant mitigating systems being relied upon to respond to initiating events to prevent undesirable consequences. The performance deficiency was also determined to be more than minor since it is similar to more than minor Example 7.e of Inspection Manual Chapter (IMC) 0612, Appendix E Examples of Minor Issues. The Finding was evaluated in accordance with Appendix K, Maintenance Risk Assessment and Risk Management Significance Determination Process, of IMC 0609, Significance Determination Process, and was determined to be of very low safety significance (Green). This Finding has a cross-cutting aspect in the area of Human Performance, Work Control, because BFN failed to implement immediate RMAs and communicate to the station personnel the change in plant risk condition and protected equipment requirements that may affect work activities. |
| Site: | Browns Ferry |
|---|---|
| Report | IR 05000259/2013011 Section 4OA4 |
| Date counted | Jun 30, 2013 (2013Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 95003 |
| Inspectors (proximate) | C Even C Moore E Guthrie J Eargle J Heinly R Skokowski |
| Violation of: | 10 CFR 50.65(a)(4) Technical Specification - Procedures 10 CFR 50.65 Technical Specification |
| CCA | H.5, Work Management |
| INPO aspect | WP.1 |
| ' | |