Finding | |
---|---|
Title | Failure To Translate The Design Into Procedure 3-SR-3.3.8.2.1(B) |
Description | The team identified a Green non-cited violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the licensees failure to translate seismic uncertainties into acceptance criteria and measuring and test equipment accuracy requirements into the Reactor Protection System circuit protector calibration surveillance procedure. This was determined to be a performance deficiency. Prompt corrective actions included determination that the equipment remained operable and entry of this issue into their corrective action program as problem evaluation report 723605 and 730495. The performance deficiency was determined to be more than minor because if left uncorrected, the performance deficiency had the potential to lead to a more significant safety concern because it could have affected the operability of the relays. The team used Inspection Manual Chapter 0609, Attachment 4, Initial Characterization of Findings, issued June 19, 2012, for mitigating systems, and Inspection Manual Chapter 0609, Appendix. A, The Significance Determination Process for Findings at Power, issued June 19, 2012, and determined the Finding to be of very low safety significance (Green) because the Finding did not result in the loss of functionality or operability of a structure, system, or component. The team did not identify a cross-cutting aspect because this performance deficiency has existed since 2006 and is not indicative of current licensee performance. |
Site: | Browns Ferry ![]() |
---|---|
Report | IR 05000259/2013011 Section 4OA4 |
Date counted | Jun 30, 2013 (2013Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 95003 |
Inspectors (proximate) | C Even C Moore E Guthrie J Eargle J Heinly R Skokowski |
Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control |
INPO aspect | |
' | |
Finding - Browns Ferry - IR 05000259/2013011 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Browns Ferry) @ 2013Q2
Self-Identified List (Browns Ferry)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||