Finding | |
---|---|
Title | Failure to Follow Procedure during Implementation of Plant Modifications to the Residual Heat Removal and Core Spray Systems |
Description | The team identified a non-cited violation (NCV) of 10 CFR 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings for the licensees failure to maintain effective configuration control as required by Procedure NPG-SPP-09.3, Rev. 13, Plant Modifications and Engineering Change Control. Specifically, the licensee partially implemented permanent plant modifications to the Residual Heat Removal (RHR) and Core Spray (CS) systems under Design Change Notices (DCN) 69466 and 69467 and left these DCNs in partially implemented status beyond two refueling outages without approval of the Vice President of Engineering. This created the potential for a loss of configuration control of the CS and RHR systems. The licensee entered this issue of concern in their corrective action program as SR 739929 and PER 740729 that included actions to evaluate completion or cancellation of the remaining portions of the DCNs. The team determined the Finding was more than minor because it was associated with the Design Control attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e. core damage). The finding was of very low significance because it was not a design or qualification deficiency, and it did not result in an actual loss of one or more trains of the RHR or CS systems and/or their function. The finding had a cross-cutting aspect in the area of Human Performance, Work Control because the licensee did not appropriately coordinate work activities by incorporating actions to address the impact of partially implemented DCNs on the plant. |
Site: | Browns Ferry ![]() |
---|---|
Report | IR 05000259/2013011 Section 4OA4 |
Date counted | Jun 30, 2013 (2013Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 95003 |
Inspectors (proximate) | C Even C Moore E Guthrie J Eargle J Heinly R Skokowski |
Violation of: | 10 CFR 50 Appendix B Criterion V |
CCA | H.5, Work Management |
INPO aspect | WP.1 |
' | |