Finding | |
---|---|
Title | Failure to Perform Evaluation of Nonconforming Material during Commercial Grade Dedication of Safety-Related Bearings |
Description | The team identified a Green non-cited violation (NCV) of 10 CFR 50 Appendix B, Criterion III, Design Control in that the licensee did not adequately evaluate a commercial grade dedication (CGD) of bearings prior to installing the bearings in a safety-related low pressure coolant injection (LPCI) motor generator (MG) set. Specifically, BFN did not perform an acceptance evaluation of non-conforming materials as required by Section 3.2.6 of NPG-SPP-04.2, Material Receipt and Inspection, Rev. 2. The licensee subsequently initiated prompt corrective actions that included an evaluation of acceptance of the installed bearings, a LPCI operability determination, an extent-ofcondition review, and entered the issue in their corrective action program (PER 729646). The Finding was more than minor because it was associated with the Design Control attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Additionally the Finding was similar to Example 5.c in Appendix E of IMC 0612. The Finding was of very low significance because the finding was a design qualification deficiency and the affected structure system component (SSC) (3EN LPCI MG set) maintained its operability. This Finding had a cross-cutting aspect in the area of Human Performance, Decision Making because the licensee did not use conservative assumptions when making the decision to accept non-conforming commercial grade bearings for safety-related use, such that nuclear safety was supported. |
Site: | Browns Ferry ![]() |
---|---|
Report | IR 05000259/2013011 Section 4OA4 |
Date counted | Jun 30, 2013 (2013Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 95003 |
Inspectors (proximate) | C Even C Moore E Guthrie J Eargle J Heinly R Skokowski |
Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control |
CCA | H.14, Conservative Bias |
INPO aspect | DM.2 |
' | |