ovember 20, 2013

SUBJECT:

NRC INSPECTION REPORT NOS. 05000295/2013012(DNMS);

05000304/2013012(DNMS); 07201037/2012001(DNMS) ZION NUCLEAR POWER STATION

Dear Mr. Daly:

On November 5, 2013, the U.S. Nuclear Regulatory Commission (NRC) completed its inspection of the independent spent fuel storage installation (ISFSI) construction activities at the permanently shut-down Zion Nuclear Power Station in Zion, Illinois. At the conclusion of the inspection on November 5, 2013, during an exit meeting, the NRC inspectors discussed the preliminary inspection findings with members of your staff. The enclosed report presents the results of this inspection.

The inspection examined the independent spent fuel storage installation pad, and vertical concrete cask design and construction, as it relates to the safe storage of dry fuel and compliance with the Commissions rules, regulations, and the conditions of your license.

Specific areas examined during the inspection are identified in the enclosed report. Within these areas, the inspection consisted of selected examinations of procedures and representative records, and interviews with personnel.

The inspection was conducted per NRC Inspection Manual 2690, Inspection Program for Dry Storage of Spent Reactor Fuel at Independent Spent Fuel Storage Installations and Guidance for Title 10 of the Code of Federal Regulations (CFR) Part 71 Transportation Packages, and used Inspection Procedures (IP) 60853 and IP 60856.

Based on the results of these inspections, the inspectors did not identify any violations of NRC requirements.

P. In accordance with Title 10 of the Code of Federal Regulations (CFR) 2.390 of the NRC's

"Rules of Practice," a copy of this letter and the enclosed report will be made available electronically for public inspection in the NRC Public Document Room or from the NRC's Agencywide Document Access and Management System (ADAMS), accessible from the NRCs website at http://www.nrc.gov/reading-rm/adams.html.

We will gladly discuss any questions you may have regarding this inspection.

Sincerely,

/RA/

Robert J. Orlikowski, Chief Materials Control, ISFSI, and Decommissioning Branch Division of Nuclear Materials Safety Docket Nos. 050-00295; 050-00304; 072-01037 License Nos. DPR-39; DPR-48 Enclosure:

Inspection Report Nos. 05000295/2013012; 05000304/2013012; 07201037/2012001 cc w/encl: Patrick Thurman, ZionSolutions, LLC Gary Bouchard, ZionSolutions, LLC Alan Parker, EnergySolutions John Christian, EnergySolutions Russ Workman, EnergySolutions cc w/o encl: Zion Distribution Service List