ML17083A245

From kanterella
Revision as of 22:00, 18 May 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Us Dept. of Defense, Armed Forces Radiobiology Research Institute, Submittal of 2016 Annual Operating Report
ML17083A245
Person / Time
Site: Armed Forces Radiobiology Research Institute
Issue date: 03/17/2017
From: Miller S I
US Dept of Defense, Armed Forces Radiobiology Research Institute
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML17083A245 (14)


Text

ARMED FORCES RADIOBIOLOGY RESEARCH INSTITUTE 8901 WISCONSIN AV!:NU!: B!:TH!:SCA, MARYL.AND 20869*6603 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Sir: March 17, 2017 Enclosed is the 2016 Annual Operating Report required by the technical specifications for the Armed Forces Radiobiology Research Institute reactor (license R-84, docket 50-170). Should you need any further information, please coL"t me q30l) 295-9245. ,.'/ / . A . ,/,,.,,. .. ...-**

Enclosure:

as cc: U.S. Nuclear Regulatory Commission ATTN: Al Adams, NRR/DPRIPRLB Mail Stop 12-D20 Washington, DC 20555-0001 STEPHEN I. MILLER Reactor Facility Director Armed Forces Radiobiology Research Institute AFRRI TRIGA Reactor Facility 1 January 2016 -31 December 2016 To satisfy the requirements of U.S. Nuclear Regulatory Commission License No. R-84 (Docket No. 50-170), Technical Specification 6.6.a. Prepared by Harry H. Spence Reactor Staff Submitted by Stephen I. Miller Reactor Facility Director Armed Forces Radiobiology Research Institute 8901 Wisconsin A venue Bethesda, MD 20889-5603 Submission of 2016 Annual Report of perjury that this report is true and correct. Date Reactor Facility Director 2016 ANNUAL REPORT TABLE OF CONTENTS Introduction General Information Section I Changes in the Facility Design, Performance Characteristics, Administrative Procedures, Operational Procedures, Results of Surveillance Tests and InspectionsSection II Energy Generated by the Reactor Core and the Number of Pulses $2.00 or Larger Section III Unscheduled ShutdownsSection IV Safety-Related Corrective Maintenance Section V Facility and Procedure Changes as Described in the Final Safety Analysis Report (FSAR), New Experiments or Tests Performed During the Year Section VI Summary of Radioactive Effluent Released Section VII Environmental Radiological SurveysSection VIII Exposures Greater Than 25% of 10 CFR 20 Limits 2016 ANNUAL REPORT INTRODUCTION The Armed Forces Radio biology Research Institute (AFRRI) reactor facility was available for irradiation services for the entire year until December 7 when it was shutdown to prepare for the installation of a new instrumentation and control system by contractors from General Atomics, scheduled to begin in January 2017. The reactor license renewal application, submitted in June 2004, was approved by the NRC with the issuance of a new 20-year operating license on November 30, 2016. Numerous revisions to both the Technical Specifications and the Safety Analysis Report were submitted as part of the relicensing process and were approved by the NRC. There were no major reactor modifications or projects during the year except preparation for installation of the new reactor console after December 7. There were no unscheduled shutdowns during 2016. The 20 l 6 annual reactor audit required by the reactor technical specifications was conducted by Mr. Bob Woodruff in January 2017. Mr. Woodruff is a health physicist in the Military Medical Operations Division. During the audit he verbally indicated that he had not found any major discrepancies in reactor operations and those conclusions are reflected in his written report. A comprehensive NRC inspection of reactor facility operations and security was conducted by Mr. Johnny Eads during January 2016. While he had several recommendations for improving reactor operations, no safety concerns or noncompliance with NRC requirements were identified. There were two RRFSS membership changes during the year. There were two reactor staff arrivals and three staff departures during the year. The remainder of this report is written in the format designated in the Technical Specifications for the AFRRI TRIGA Reactor Facility. Items not specifically required are presented in the General Information section. The following sections correspond to the required items listed in Section 6.6.b. of the Technical Specifications.

GENERAL INFORMATION All personnel held the listed positions throughout the year unless otherwise specified. Key AFRRI personnel (as of 31December2016) are as follows: 1. AFRRI Director -L. Andrew Huff, Col, USAF Radiation Sciences Department (RSD) Head -Stephen I. Miller (SRO) Radiation Safety Officer-Daniel Shaw (as of 06 September) 2 Reactor Facility Director and Facility Radiation Manager -Stephen I. Miller (SRO) 3. Reactor operations personnel: Reactor Operations Supervisor-Walter D. Tomlinson (SRO) (as of 23 March) SRO Training Coordinator-Walter D. Tomlinson (SRO) (as of23 March) Maintenance Specialist -Walter D. Tomlinson (SRO) Records Administration Specialist -Harry H. Spence (as of 02 February) 4. Other Senior Reactor Operators: Jason Jacot, SFC, USA (through 23 March) 5. Operator candidates: Sacha T. Moore, SFC, USA (as of26 July) David D. Manzanares, SFC, USA (through 05 August) Robert E. McMahon, MAJ, USA (through 21 November) 6 .. Newly licensed operators: None 7. Additions to staff during 2016: Sacha T. Moore, SFC, USA (as of26 July) Harry H. Spence (as of 02 February) NOTE: Mr. Spence formerly held a SRO license at the AFRRI reactor and retired in June 2013. He returned as an unlicensed part-time staff member in February 2016. 8. Departures during 2016: Jason Jacot (SRO), SFC, USA (as of23 March) David D. Manzanares, SFC, USA (as of05 August) Robert E. McMahon, MAJ, USA (as of21 November)

9. There were two change to the Reactor and Radiation Facilities Safety Subcommittee (RRFSS) during 2016. Dr. David Lesser replaced LTC Clayton Carr, USA on 06 September and Mr. Daniel Shaw replaced CDR Marie Parry, USN also on 06 September. In accordance with the requirements set forth in Section 6.2.1.1. of the Technical Specifications for the AFRRI TRI GA Reactor Facility, the RRFSS consisted of the following members as of 31 December 2016. Regular members are: Radiation Safety Officer: -Daniel Shaw Reactor Facility Director and Facility Radiation Manager -Stephen I. Miller. Reactor Operations Specialist -Vincent Adams Health Physics Specialist -Joe Pawlovich Chairman and Director's Representative -Dr. David Lesser Special nonvoting member -David Lake, Montgomery County Government (Department of Environmental Protection) Recorder -Harry H. Spence Two meetings were held in 2016: 14 July 17November I L __ _ SECTION I Changes in the Facility Design, Performance Characteristics, Administrative Procedures, Operational Procedures, Results of Surveillance Tests and Inspections A summary of changes to the facility design, performance characteristics, administrative procedures, and operational procedures as well as the results of surveillance testing are provided in this section. A. DESIGN CHANGES There were two design changes to the reactor facility during 2016 that were reviewed and approved under provisions of 10 CFR 50.59: 23 February .,-Addition of incandescent lamps to visually check the status of the transient rod up and down limit switches. 19 May -Removal and replacement of the automatic secondary water treatment system. This irivolved the upgrading of a former cooling tower water treatment system that was installed in September 2004 after 10 CFR 50.59 approval. Revisions were also made to Chapter 7, Instrumentation and Control Systems, of the FSAR to complete the relicensing package and to prepare for the installation of the new reactor console in 2017 (see Section V). B. PERFORMANCECHARACTERISTICS There were no changes to the performance characteristics of the core during 2016. All fuel elements and control rods remained in place for operations throughout the year until December 7 as noted in the Introduction. C. ADMINISTRATIVE PROCEDURES There were no changes to the Administrative Procedures during 2016. D. OPERATIONAL PROCEDURES
  • There were no changes to the Operational Procedures during 2016. E. RESULTS OF SURVEILLANCE TESTS AND INSPECTIONS All maintenance and surveillance tasks during 2016 were accomplished as normally scheduled during the year. There were no reactor malfunctions during 2016.

The 2016 annual reactor audit required by the reactor technical specifications was conducted by Mr. Bob Woodruff in January 2017. Mr. Woodruff is a health physicist in the Military Medical Operations Division. During the audit he verbally indicated that he had not found any major discrepancies in reactor operations and those conclusions are reflected in his written report. A comprehensive NRC inspection of reactor facility operations and security was conducted by Mr. Johnny Eads during January 2016. While he had several recommendations for improving reactor operations, no safety concerns or noncompliance with NRC requirements were identified.

SECTION II Energy Generated by the Reactor Core and the Number of Pulses $2.00 or Larger Month Kilowatt Hours JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC TOTAL 937.5 1199.7 312.1 308.8 111.8 339.6 389.4 0.0 0.0 0.0 43.0 88.2 3730.0 Total energy generated in 2016: 3,730.1 kWh Total energy on fuel elements: 1,156,793.7 kWh Total energy on FFCRs*: 423,996.0 kWh Total pulses this year;::: $2.00: 0 Total pulses on fuel elements;::: $2.00: 4,219 Total pulses on FFCRs*;::: $2.00: 107 Total pulses this year: 18 Total pulses on fuel elements: 12,189 Total pulses on FFCRs*: 2,424 *Fuel-followed control rods SECTION III Unscheduled Shutdowns There were no unscheduled shutdowns during 2016. SECTION IV Safety-Related Corrective Maintenance There were no reactor malfunctions during 2016.

SECTIONV Facility and Procedure Changes as Described in the Final Safety Analysis Report (FSAR), New Experiments or Tests Performed During the Year A. FACILITY CHANGES AS DESCRIBED IN THE FSAR Chapter 7, Instrumentation and Control Systems and Chapter 13, Accident Analysis of the FSAR were extensively revised during the reactor relicensing process and were approved by the NRC when the licensed was renewed on November 30. B. PROCEDURE CHANGES AS DESCRIBED IN THE FSAR There were no changes to procedures as described in the FSAR. C. NEW EXPERIMENTS OR TESTS No new experiments or tests were performed during the reporting period that were not encompassed by the FSAR. There were two safety evaluations for changes n.ot submitted to the NRC, pursuant to the provisions of 10 CFR 50.59 (see Section l.D. above).

SECTION VI Summary of Radioactive Effluent Released A. Liquid Waste: The reactor produced no liquid waste during 2016. B. Gaseous Waste: There were no particulate discharges in 2016. C. Solid Waste: SECTION VII The total activity of Argon-41 discharged in 2016 was 1.07 curies. The estimated effluent concentration from the release of Argon-41 represents under 1 % of the constraint limit for unrestricted areas (10 CPR 20.l lOl(d) and Table 2, Appendix B, 10 CPR 20). Quarterly: Jan -Mar 2016 Apr -Jun 2016 Jul -Sep 2016 Oct -Dec 2016 0.70 Ci 0.01 Ci 0.36 Ci 0.00 Ci All solid radioactive waste material was transferred to the APRRI byproduct license; none was disposed of under the R-84 reactor license. Environmental Radiological Surveys All environmental sampling of soil and vegetation yielded radionuclide levels within the background range. The radionuclides that were detected were those expected from natural background and from long-term fallout from nuclear weapons testing. The calculated annual dose, due to Argon-41 release to the environment for 2016, was 0.06 mRem at the location of maximum public exposure. The maximum exposure is calculated at a location 91 meters from the release point as described in the PSAR. Exposure to the general population at the boundary of the Naval Support Activity Bethesda is significantly less due to the diffusion of Argon-41 in the atmosphere. The constraint limit for exposure to the public

  • established under 10 CPR 20.l lOl(d) is 10 millirem per year. The exposure dose was calculated using COMPLY code, level 2, which is the most conservative level of COMPLY. Emissions due to reactor operations were 0.06 millirem, or less than 1 % of the 10 millirem constraint limit, for the entire year. The reactor in-plant surveys, specified in Health Physics Procedure (HPP) 3-2, all resulted in readings that were less than the action levels specified in HPP 0-2.

L_ __ . SECTION VIII Exposures Greater than 25% of 10 CFR 20 Limits There were no doses to reactor staff personnel or reactor visitors greater than 25% of 10 CFR 20 occupational and public radiation dose limits.