ML22237A210

From kanterella
Revision as of 06:31, 2 September 2023 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Revised Final Status Survey Release Record, Irsf/Fire Training Area, Survey Unit 10202D, Revision 1
ML22237A210
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 08/17/2022
From: Yetter R
ZionSolutions
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML22237A206 List:
References
ZS-2022-040
Download: ML22237A210 (212)


Text

ZION STATION RESTORATION PROJECT FINAL STATUS SURVEY RELEASE RECORD IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D REVISION 1

Digitally signed by Robert F Yetter III DN: C=US, O=EnergySolutions, CN=Robert F Yetter III, E=rfyetteriii@energysolutions.com Robert F Yetter IIIReason: I am the author of this document Location: your signing location here Date: 2022-08-17 18:00:32 Foxit PhantomPDF Version: 9.7.0 Digitally signed by Robert F_ Yetter Robert F_ DN: C=US, OU=EnergySolutions, CN=Robert F_

Yetter, E=rfyetter@energysolutions.com Reason: I am the author of this document Yetter Location: your signing location here Date: 2022-08-18 08:54:18 Foxit PhantomPDF Version: 9.7.0

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D TABLE OF CONTENTS

1. EXECUTIVE

SUMMARY

........................................................................................................................................................5

2. SURVEY UNIT DESCRIPTION ...............................................................................................................................................5
3. CLASSIFICATION BASIS .......................................................................................................................................................6
4. DATA QUALITY OBJECTIVES ..............................................................................................................................................7
5. SURVEY DESIGN ..................................................................................................................................................................11
6. SURVEY IMPLEMENTATION .............................................................................................................................................17
7. SURVEY RESULTS ................................................................................................................................................................18
8. QUALITY CONTROL ............................................................................................................................................................24
9. INVESTIGATIONS AND RESULTS .....................................................................................................................................24
10. REMEDIATION AND RESULTS ......................................................................................................................................24
11. CHANGES FROM THE SURVEY PLAN .........................................................................................................................24
12. DATA QUALITY ASSESSMENT .....................................................................................................................................24
13. ANOMALIES ......................................................................................................................................................................25
14. CONCLUSION ....................................................................................................................................................................25
15. REFERENCES ....................................................................................................................................................................25
16. ATTACHMENTS ................................................................................................................................................................26 LIST OF TABLES TABLE 1 - DOSE SIGNIFICANT RADIONUCLIDES AND MIXTURE ...........................................................................................................8 TABLE 2 - BASE CASE DCGLS FOR SURFACE SOILS (BCDCGLSS)......................................................................................................9 TABLE 3 - BASE CASE DCGLS FOR SUBSURFACE SOILS (BCDCGLSB) ...............................................................................................9 TABLE 4 - OPERATIONAL DCGLS FOR SURFACE SOILS (OPDCGLSS) ...............................................................................................10 TABLE 5 - OPERATIONAL DCGLS FOR SUBSURFACE SOILS (OPDCGLSB).........................................................................................10 TABLE 6 - SURROGATE RATIOS .........................................................................................................................................................11 TABLE 7 - INVESTIGATION LEVELS....................................................................................................................................................13 TABLE 8 - SYSTEMATIC SAMPLE MEASUREMENT LOCATIONS ..........................................................................................................14 TABLE 9 - SYNOPSIS OF SURVEY DESIGN ..........................................................................................................................................16 TABLE 10 - INSTRUMENTS AND DETECTORS......................................................................................................................................18 TABLE 11 - SYNOPSIS OF SCAN RESULTS ..........................................................................................................................................18 TABLE 12 -

SUMMARY

OF GAMMA SPECTROSCOPY RESULTS FOR SURFACE SOIL SAMPLES COMPRISING THE STATISTICAL SAMPLE POPULATION .............................................................................................................................................................................21 TABLE 13 -

SUMMARY

OF GAMMA SPECTROSCOPY RESULTS FOR SUBSURFACE SOIL SAMPLES .......................................................21 TABLE 14 -

SUMMARY

OF GAMMA SPECTROSCOPY RESULTS FOR QC SURFACE SOIL SAMPLE.........................................................22 TABLE 15 - SUM OF FRACTIONS FOR SURFACE SOIL SAMPLES, WHEN COMPARED TO THE OPDCGLS (SYSTEMATIC).......................22 TABLE 16 - SUM OF FRACTIONS FOR SUBSURFACE SOIL SAMPLES, WHEN COMPARED TO THE OPDCGLS ........................................23 TABLE 17 - SUM OF FRACTIONS FOR SURFACE SOIL SAMPLES, WHEN COMPARED TO THE OPDCGLS (QC) .....................................23 TABLE 18 - BASIC STATISTICAL PROPERTIES OF SYSTEMATIC SAMPLE POPULATION .......................................................................23 LIST OF FIGURES FIGURE 1 - CLASS 3 OPEN LAND SURVEY UNITS FROM FIGURE 2-6 OF THE LTP ................................................................................6

[2]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D LIST OF ACRONYMS AND ABBREVIATIONS ALARA As Low As Reasonably Achievable AMCG Average Member of the Critical Group BcDCGL Base Case Soil DCGLs BcSOF Base Case Sum of Fractions C/LT Characterization/License Termination cpm Counts per minute DQO Data Quality Objective DCGL Derived Concentration Guideline Level EMC Elevated Measurement Comparison FSS Final Status Survey GPS Global Positioning System HTD Hard-to-Detect HSA Historical Site Assessment IC Insignificant Contributor LBGR Lower Bound of the Gray Region LTP License Termination Plan MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual MDC Minimum Detectable Concentration MDCR Minimum Detectable Count Rate NAD North American Datum NaI Sodium Iodide OpDCGL Operational Derived Concentration Guideline Level OpSOF Operational Sum of Fractions QAPP Quality Assurance Project Plan QC Quality Control RE Radiological Engineer ROC Radionuclides of Concern SOF Sum of Fractions

[3]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D TEDE Total Effective Dose Equivalent TSD Technical Support Document UBGR Upper Bound of the Gray Region VSP Visual Sample Plan ZNPS Zion Nuclear Power Station ZSRP Zion Station Restoration Project

[4]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D

1. EXECUTIVE

SUMMARY

This Final Status Survey (FSS) Release Record for Survey Unit 10202D, IRSF/Fire Training Area, has been generated for the Zion Station Restoration Project (ZSRP) in accordance with ZionSolutions procedure ZS-LT-300-001-005, Final Status Survey Data Reporting, (Reference 1) and satisfies the requirements of Section 5.11 of the Zion Station Restoration Project License Termination Plan, (LTP) (Reference 2).

An FSS package (L1-10202D-F Plan #2) was developed in accordance with ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package Development, (Reference 3), the ZSRP LTP, and guidance from NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual, (MARSSIM) (Reference 4). Plan #2 addresses the reperformance of FSS in survey unit 10202D due to the excavation and fill activities that occurred in March 2022 in a portion of the survey unit after initial FSS was completed.

This open land survey unit has a MARSSIM classification of 1. A survey plan was designed based upon use of the Sign Test as the nonparametric statistical test for compliance. Both the Type I () and Type II () decision error rates were set at 0.05. Eighteen systematic surface soil samples were acquired from the survey unit. In addition, surface scanning was performed on 100% of the total surface area in the survey unit. No areas of elevated activity were detected during the scans. The analytical results for all soil samples taken in Survey Unit 10202D indicate that the Sum of Fractions (SOF) for each sample, when compared to the Operational Derived Concentration Guideline Levels (OpDCGL), was less than 1.0, with a maximum Operational SOF (OpSOF) of 0.0687. The mean OpSOF for the systematic samples was 0.0208. The mean Base Case SOF (BcSOF), when the analytical results were compared to the Base Case DCGLs (BcDCGL), was 0.005, which results in a dose assigned to the survey unit of 0.133 mrem/yr.

Therefore, the null hypothesis is rejected and survey unit 10202D is acceptable for unrestricted release.

2. SURVEY UNIT DESCRIPTION Survey Unit 10202D, IRSF/Fire Training Area, is a Class 1 open land survey unit and is 1,680 m2 in size. It is bounded on the west by survey unit 10203E, the south by survey units 10201C, 10201D, 10201E and 12101, the east by survey units 10201C and 10201D, and the north by survey unit 10202C.

The topography of the survey unit is mainly flat with some small dips and depressions. The soil is mostly loam. A fence runs along the eastern border of the survey unit.

The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Illinois State Plane System North American Datum (NAD) 1983 East. The reference coordinates associated with the sample locations in this survey unit are presented in Table 8.

[5]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D

3. CLASSIFICATION BASIS Survey Unit 10202D was classified in accordance with ZionSolutions procedure ZS-LT-300-001-002, Survey Unit Classification, (Reference 5).

The area encompassing this survey unit was described in the Zion Station Historical Site Assessment (HSA) (Reference 6) as the IRSF/Fire Training Area and was located within survey unit 10202 as identified in Figure 3 of the HSA. Subsequently, this area was described as the IRSF/Fire Training Area (survey unit 10202) in Table 2-4 of the ZSRP LTP as represented in Figure 2-6 of the LTP and replicated as Figure 1 below.

Figure 1 - Class 3 Open Land Survey Units from Figure 2-6 of the LTP On June 12, 2017, due to changing radiological and operational conditions brought about by site decommissioning activities inside or adjacent to this area, Survey Unit 10202 was reclassified as Class 1, and divided into four (4) survey units: 10202A, 10202B, 10202C and 10202D.

The initial Final Status Survey of 10202D was completed in April 2019 as a Class 1 survey unit.

This classification remains applicable to this survey design.

A Radiological Engineer (RE)/Characterization/License Termination (C/LT) Supervisor performed a visual inspection and walk-down of the survey unit on 05/31/2022 prior to performing this FSS. The purpose of the walk-down was to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

A final classification assessment was performed in accordance with procedure ZS-LT-300-001-002, Survey Unit Classification as part of the survey design for FSS. The assessment confirmed that Survey Unit 10202D was correctly classified as Class 1.

[6]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D

4. DATA QUALITY OBJECTIVES Final Status Survey planning and design hinges on coherence with the Data Quality Objective (DQO) process to ensure, through compliance with explicitly defined inputs and boundaries, that the primary objective of the survey is satisfied. The DQO process is described in the ZSRP LTP in accordance with MARSSIM. The appropriate design for a given survey is developed using the DQO process as outlined in Appendix D of MARSSIM.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit would satisfy the primary objective of the FSS sample plan.

The primary objective of the FSS sample plan is to demonstrate that the level of residual radioactivity in survey unit 10202D does not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

ZionSolutions Technical Support Document (TSD)11-001, Technical Support Document for Potential Radionuclides of Concern During the Decommissioning of the Zion Station, (Reference 7), written in 2012, established the basis for an initial suite of potential ROC for the decommissioning of the Zion Nuclear Power Station (ZNPS).

ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms, (Reference 8), completed in February 2017, was written to refine the initial selection of ROC for decommissioning at ZSRP. The list of ROC was evaluated using Containment Building(s) and Auxiliary Building concrete core analysis data to evaluate the dose significance of each radionuclide in the end state model. Section 4.4 of the TSD evaluated the results of the characterization data of surveys taken of soils. The following conclusion was reached: The results of surface and subsurface soil characterization in the impacted area surrounding Zion indicate that there is minimal residual radioactivity in soil. Essentially all of the soil results were reported as non-detectable. Other than Cs-137 at very low levels, and Co-60 at a concentration of 0.24 pCi/g in one sample, the results for all radionuclides were less than MDC. Therefore, the direct determination of radionuclide mixture fractions for initial suite radionuclides in soil is not technically feasible due to the MDC biasing issues discussed above. Based on a generalized assumption that the contaminated water that caused concrete contamination would be similar to the source of soil contamination, the ROC and radionuclide mixture derived for the Auxiliary Building concrete was considered to be reasonably representative of soils for FSS planning and implementation.

[7]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D The ROC for surface soils are listed in Table 1 below (From Table 5-2 of the LTP):

Table 1 - Dose Significant Radionuclides and Mixture Auxiliary Building Radionuclide  % of Total Activity (normalized)(1)(2)

Co-60 0.92%

Ni-63 23.71%

Sr-90 0.05%

Cs-134 0.01%

Cs-137 75.32%

(1) Based on maximum percent of total activity from Table 20 of TSD 14-019, normalized to one for the dose significant radionuclides (2) Does not include dose significant radionuclides for activated concrete (H-3, Eu-152, Eu-154).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soils.

Surface soil is defined as soil residing in the first 0.15 m (6 inches) layer of soil. A subsurface soil category, which is defined as a layer of soil beginning at the surface but extending to a depth of 1 m is also assessed to allow for flexibility in compliance demonstration if contamination deeper than 0.15 m is encountered. Site-specific DCGLs for soil were calculated for both the 0.15 m and 1 m thicknesses. Based on characterization data and historical information, there are no expectations of encountering a source term geometry that is comprised of a clean surface layer of soil over a contaminated subsurface soil layer. ZionSolutions TSD 14-011, Soil Area Factors, (Reference 9) and LTP Chapter 6, section 6.8 provides the exposure scenarios and modeling parameters that were used to calculate the site- specific DCGLs for soils (referred to as Base Case Soil DCGLs [BcDCGL] in this Release Record).

At ZNPS, compliance is demonstrated through the summation of dose from four distinct source terms for the end-state (basements, soils, buried pipe and groundwater). Basements are comprised of the summation of four structural source terms (surfaces, embedded pipe, penetrations and fill).

When applied to soil, the DCGLs are expressed in units of activity per unit of mass (pCi/g). The unity rule is applied when there is more than one ROC. The measurement results for each singular ROC present in the mixture are compared against their respective DCGL to derive a dose fraction.

The surface and subsurface soil BcDCGLs for the unrestricted release of open land survey units

[8]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D are listed in Tables 5-5 and 5-6 of the LTP and are provided in Table 2 and Table 3, respectively.

The Insignificant Contributor (IC) dose percentage of 10% was used to adjust the DCGLs in soils to account for the dose from the eliminated IC radionuclides.

Table 2 - Base Case DCGLs for Surface Soils (BcDCGLSS)

Surface Soil DCGL Radionuclide (pCi/g)

Co-60 4.26 Cs-134 6.77 Cs-137 14.18 Ni-63 3,572.10 Sr-90 12.09 Table 3 - Base Case DCGLs for Subsurface Soils (BcDCGLSB)

Subsurface Soil Radionuclide DCGL (pCi/g)

Co-60 3.44 Cs-134 4.44 Cs-137 7.75 Ni-63 763.02 Sr-90 1.66 Each radionuclide-specific BcDCGL is equivalent to the level of residual radioactivity (above background levels) that could, when considered independently, result in a Total Effective Dose Equivalent (TEDE) of 25 mrem per year to an Average Member of the Critical Group (AMCG).

To ensure that the summation of dose from each source term is 25 mrem/yr or less after all FSS is completed, the BcDCGLs are reduced based on an expected, or a priori, fraction of the 25 mrem/year dose limit from each source term. The reduced DCGLs, or OpDCGLs, can be related to the BcDCGLs as an expected fraction of dose based on an a priori assessment of what the expected dose should be based on the results of site characterization, process knowledge and the extent of planned remediation. The OpDCGL is then used as the DCGL for the FSS design of the survey unit (calculation of surrogate DCGLs, investigation levels, etc.). Details of the OpDCGLs derived for each dose component and the basis for the applied a priori dose fractions are provided in ZionSolutions TSD 17-004, Operational Derived Concentration Guideline Levels for Final Status Survey, (Reference 10).

The OpDCGLs for the FSS of surface and subsurface soils are listed in Tables 5-7 and 5-8 of the LTP and are presented in Table 4 and Table 5, respectively.

[9]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Table 4 - Operational DCGLs for Surface Soils (OpDCGLSS)

Surface Soil DCGL Radionuclide (pCi/g)

Co-60 1.091 Cs-134 1.733 Cs-137 3.630 Ni-63 914.458 Sr-90 3.095 Table 5 - Operational DCGLs for Subsurface Soils (OpDCGLSB)

Subsurface Soil Radionuclide DCGL (pCi/g)

Co-60 0.881 Cs-134 1.137 Cs-137 1.984 Ni-63 195.333 Sr-90 0.425 In accordance with NUREG-1757, Appendix G, if the HSA indicates that there is no likelihood of substantial subsurface residual radioactivity, subsurface surveys are not necessary. The HSA as well as the results of the extensive characterization of subsurface soils in the impacted area surrounding the Zion facility have shown that there is minimal residual radioactivity in subsurface soil. Consequently, Zion proposes to perform minimal subsurface sampling during FSS.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest at the required scan MDC, which for Class 1 Open Land survey units, is the a priori elevated measurement comparison DCGL (DCGLEMC). Survey instrument response checks were required prior to issuance and after the instrument had been used. Control and accountability of survey instruments was required to ensure the quality and prevent the loss of data.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. The actual recorded value was used as the recorded FSS result for measurement and/or sample values that are less than MDC. Negative values were recorded as zero. For radionuclides less than MDC, the value representing the highest abundance was selected. Results were not reported as less than MDC. Sample report summaries included unique sample identification, analytical method, radionuclide, result, uncertainty, laboratory data qualifiers, units, and the observed MDC.

[10]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D In accordance with the LTP, for laboratory analysis, MDCs less than 10% of the OpDCGL were preferable while MDCs up to 50% of the OpDCGL were acceptable. The maximum acceptable MDC for measurements obtained using field instruments was the a priori DCGLEMC, which was calculated using the methodology described in the LTP, section 5.6.4.3.

5. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in procedure ZS-LT-300-001-001.

The DQO process determined that Co-60, Ni-63, Sr-90, Cs-134 and Cs-137 would be the ROC in survey unit 10202D. During FSS, concentrations for Hard-to-Detect (HTD) ROC Ni-63 and Sr-90 are inferred using a surrogate approach. Cs-137 is the principle surrogate radionuclide for Sr-90 and Co-60 is the principle surrogate radionuclide for Ni-63. The mean, maximum and 95%

Upper Confidence Level (UCL) of the surrogate ratios for concrete core samples taken in the Auxiliary Building basement were calculated in ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms, and are presented in Table 6. The maximum ratios will be used in the surrogate calculations during FSS unless area specific ratios are determined by continuing characterization.

Table 6 - Surrogate Ratios Auxiliary Building Ratios Mean Max 95%UCL Ni-63/Co-60 44.143 180.450 154.632 Sr-90/Cs-137 0.001 0.002 0.002 For the FSS of survey unit 10202D, the surrogate OpDCGLs for Co-60 and Cs-137 were computed based on the maximum ratios from Table 6. The equation for calculating a surrogate DCGL is as follows:

Equation 1 1

=

1 2 3

[( ) + ( ) + ( ) + ( )]

2 3 Where: DCGLSur = Surrogate radionuclide DCGL DCGL2,3n = DCGL for radionuclides to be represented by the surrogate Rn = Ratio of concentration (or nuclide mixture fraction) of radionuclide n to surrogate radionuclide Using the OpDCGLs for surface soils presented in Table 4 and the maximum ratios from Table

[11]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D 6, the following surrogate calculations for surface soils were performed:

Equation 2 1

(137) = = 3.622 /

1 0.002

[(3.630 )+( )]

(137) 3.095 (90)

The surrogate Op DCGL for surface soils that was used for Cs-137 in this survey unit for direct comparison of surface soil sample results to demonstrate compliance is 3.622 pCi/g.

Equation 3 1

(60) = = 0.898 /

1 180.45

[( )+( )]

1.091(60) 914.458(63)

The surrogate OpDCGL for surface soils that was used for Co-60 in this survey unit for direct comparison of surface soil sample results to demonstrate compliance is 0.898 pCi/g.

Using the BcDCGLs presented in Table 2 and the maximum ratios from Table 6, the following surrogate calculations were performed:

Equation 4 1

(137) = = 14.15 /

1 0.002

[(14.18 )+( )]

(137) 12.09 (90)

The surrogate BcDCGL for surface soils that was used for Cs-137 in this survey unit for calculating the DCGLEMC is 14.15 pCi/g.

Equation 5 1

(60) = = 3.51 /

1 180.45

[(4.26 )+( )]

(60) 3572.10(63)

The surrogate BcDCGL for surface soils that was used for Co-60 in this survey unit for calculating the DCGLEMC is 3.51 pCi/g.

For this Class 1 open land survey unit, the Investigation Levels for area scanning and soil sample measurement results are those levels specified in LTP Chapter 5, Table 5-25 and are reproduced below in Table 7.

[12]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Table 7 - Investigation Levels Direct Investigation Classification Scan Investigation Levels Levels

>Operational DCGL or >MDCscan if Class 1 > Operational DCGL MDCscan is greater than Operational DCGL The MDCscan for the 2350-1/44-10 was calculated using the methodology of TSD-11-004, Ludlum Model 44-10 Detector Sensitivity (Reference 11) with the following parameters:

  • background count rate of 5,500 counts per minute (cpm)
  • scan speed of 0.25 m/sec
  • distance from detector to surface of 2
  • isotopic mix of 95% Cs-137 and 5% Co-60 The calculated MDCscan value was 2.78 pCi/g, which was greater than the calculated Surrogate DCGLs, therefore the scan investigation level was set at the MDCscan of the 2350-1/44-10. The collimator was not used during the scan surveys.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. This approach was conservative since it included background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with procedure ZS-LT-300-001-001 Final Status Survey Package Development. The relative shift (/) for the survey unit data set is defined as shift (), which is the Upper Bound of the Gray Region (UBGR), or the DCGL (SOF of 1) minus the Lower Bound of the Gray Region (LBGR) (SOF of 0.5), divided by sigma (), which is the standard deviation of the data set used for survey design. The optimal value for / should range between 1 and 3. The largest value the / can have is 3. If the /

exceeds 3, then the value of 3 will be used for /. For this survey design, a conservative estimate of the sample variability of 0.30 was used as the coefficient of variation to calculate /.

The calculated relative shift was 1.67. Both the Type I error, or value and the Type II error, or value was set at 0.05. The sample size from Table 5.5 of MARSSIM that equates to the Type I and Type II error of 0.05 for use with the Sign Test is an N value of 17.

VSP was used to generate the sample map, in accordance with ZS-LT-300-001-001. The map used was provided by the Survey Mapping/CAD Specialist, with coordinates based on the NAD standard topographical grid coordinate system. The number of samples generated by VSP for a systematic triangular grid was 18. The Prospective Power Curve generated by VSP showed adequate power for the survey design.

In accordance with Section 5.6.4.3 of the LTP, the a priori DCGLEMC values were calculated for

[13]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D the gamma emitting ROC to ensure that the MDCSCAN of the selected instrument was sufficient to detect small areas of elevated activity in the survey unit. The calculations were:

1680

  • To calculate the area bounded by the systematic samples: = = = 93.3 2 18
  • From the LTP, Table 5-16, the Area Factors for the next larger area, 100 m2 area were used:

o Cs-137 - 1.62 o Cs-134 - 1.44 o Co 1.29

  • The DCGLEMC is the Surrogate Base Case DCGL times the Area Factor:

o The DCGLEMC for Cs-137 = 1.62 14.15 = 22.92 /

o The DCGLEMC for Cs-134 - 1.44 6.77 = 9.75 /

o The DCGLEMC for Co 1.29 3.51 = 4.53 /

The calculated MDCSCAN, 2.78 pCi/g, is less than the DCGLEMC values calculated above, therefore, the spacing of the statistical systematic sampling and measurement locations was adequate to detect small areas of elevated radioactivity. No adjustment to the sample number was required.

The implementation of quality control measures as referenced by LTP Chapter 5, Section 5.9 and ZionSolutions ZS-LT-01, Quality Assurance Project Plan (for Characterization and FSS)

(QAPP) (Reference 12) includes the collection of a soil sample for split sample analysis on 5%

of the soil samples taken in a survey unit with the locations selected at random. One (1) surface soil sample, L1-10202D-FQGS-213-SS, was selected randomly for split sample analysis for the FSS of this survey unit.

In accordance with section 5.7.1.6.2 of the LTP, a subsurface soil sample was taken at 10% of the systematic surface soil sample locations in the survey unit with the location(s) selected at random. Locations L1-10202D-FSGS-211-SB and L1-10202D-FSGS-216-SB were selected for this survey unit.

The locations of the seventeen (17) systematic samples are listed in Table 8. Also included are the locations of the two (2) subsurface samples. A map of the systematic sample locations is included in Attachment 1.

Table 8 - Systematic Sample Measurement Locations NORTHING EASTING MEASUREMENT ID (meters) (meters)

L1-10202D-FSGS-201-SS 641904.69 343759.78 L1-10202D-FSGS-202-SS 641904.69 343770.46 L1-10202D-FSGS-203-SS 641913.94 343722.39 L1-10202D-FSGS-204-SS 641913.94 343733.07

[14]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D NORTHING EASTING MEASUREMENT ID (meters) (meters)

L1-10202D-FSGS-205-SS 641913.94 343743.75 L1-10202D-FSGS-206-SS 641913.94 343754.44 L1-10202D-FSGS-207-SS 641913.94 343765.12 L1-10202D-FSGS-208-SS 641913.94 343775.80 L1-10202D-FSGS-209-SS 641923.19 343717.05 L1-10202D-FSGS-210-SS 641923.19 343727.73 L1-10202D-FSGS-211-SS 641923.19 343738.41 L1-10202D-FSGS-212-SS 641923.19 343749.10 L1-10202D-FSGS-213-SS 641923.19 343759.78 L1-10202D-FSGS-214-SS 641923.19 343770.46 L1-10202D-FSGS-215-SS 641932.44 343711.71 L1-10202D-FSGS-216-SS 641932.44 343722.39 L1-10202D-FSGS-217-SS 641932.44 343733.07 L1-10202D-FSGS-218-SS 641932.44 343743.75 L1-10202D-FSGS-211-SB 641923.19 343738.41 L1-10202D-FSGS-216-SB 641932.44 343722.39 ZSRP LTP Chapter 5, section 5.1 states that soil samples will be collected during FSS to confirm the HTD to surrogate radionuclide ratios (Table 6). Ten percent (10%) of the FSS samples collected from open land survey units will be analyzed for HTD ROC. Only HTD radionuclides included as ROC (Ni-63 and Sr-90 for soils) will be analyzed in the FSS confirmatory samples. For soil samples with positive results for both a HTD ROC and the corresponding surrogate radionuclide (Cs-137 or Co-60), the HTD surrogate ratio will be derived and compared against the maximum ratio (see Table 6). The maximum ratios (Table

6) will be used unless specific survey information supports the use of a surrogate ratio that is specific to the area. In these cases, the survey unit-specific radiological data and the derived surrogate ratios will be submitted to the NRC for approval. If approved, then the survey unit-specific ratios used and the survey data serving as the basis for the surrogate ratios will be documented in the release record for the survey unit.

In addition, LTP Chapter 5, section 5.1 states that if levels of residual gamma radioactivity in an individual soil sample exceed an OpSOF of 0.1, then the sample(s) will be analyzed for HTD ROC. This threshold was not encountered during the FSS of survey unit 10202D.

The selection of two (2) soil samples met the requirement that 10% of the samples collected for the FSS of survey unit 10202D be analyzed for HTD ROC. Sample numbers L1-10202D-FSGS-215-SS and L1-10202D-FSGS-216-SS were selected based on exhibiting the highest concentration of Cs-137 that was positively detected. Each sample was sent off-site (GEL Laboratories) for analysis of the HTD ROC as specified in LTP Chapter 5, section 5.1. Table 9 provides a synopsis of the survey design for survey unit 10202D.

[15]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Table 9 - Synopsis of Survey Design FEATURE DESIGN CRITERIA BASIS Survey Unit Area 1,680 m2 GPS measurements of area

  • = 0.30
  • UBGR = SOF of 1
  • LBGR = SOF of 0.5 Number of Surface 18 (Systematic)
  • Type I error = 0.05 Soil Samples
  • Type II error = 0.05
  • / = 1.67 (MARSSIM Table 5.5)

(LTP Chapter 5, section Grid Spacing 10.4 m 5.6.4.5.2)

  • Co 1.091 pCi/g
  • Cs-134 - 1.733 pCi/g Operational DCGLs for Surface DCGLs
  • Ni 914.458 pCi/g (LTP Chapter 5, Table 5-7)
  • Sr 3.095 pCi/g A minimum of two (2) soil samples HTD ROC Analysis (LTP Chapter 5, section 5.1) selected for HTD ROC analysis Measurement Operational DCGL (LTP Chapter 5, Table 5-25)

Investigation Level Scan Survey Area 100% (LTP Chapter 5, Table 5-24)

Coverage Quality Control One (1) surface soil sample selected (LTP Chapter 5, section 5.9)

(QC) randomly for split sample analysis Number of Two (2) systematic surface soil sample (LTP Chapter 5, section Subsurface Soil locations selected, at locations 11 and 5.7.1.6.2)

Samples 16

[16]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D

6. SURVEY IMPLEMENTATION Survey instructions for this FSS were incorporated into and performed in accordance with FSS Sample Plan L1-10202D-F #2, which was developed in accordance with ZionSolutions procedure ZS-LT-300-001-001. The FSS unit was inspected and controlled in accordance with ZionSolutions procedure ZS-LT-300-001-003, Isolation and Control for Final Status Survey, (Reference 13).

For survey unit 10202D, compliance with the unrestricted release criteria was demonstrated through a combination of surface scanning with a Ludlum Model 44-10 gamma detector and the sampling of surface soil for isotopic analysis. In accordance with the LTP Chapter 5, two (2) subsurface samples were obtained. Also, if during the performance of FSS, the analysis of a surface soil sample, or the results of a surface gamma scan indicated the potential presence of residual radioactivity at a concentration of 75% of the subsurface OpDCGL, then a biased subsurface soil sample(s) would have been taken to the appropriate depth within the area of concern as part of the investigation. This threshold was not encountered during the FSS of survey unit 10202D.

FSS field activities were conducted under FSS Sample Plan L1-10202D-F #2. A Field Log (ZS-LT-300-001-001 Attachment 14) was used to document field activities and other information pertaining to the performance of the FSS.

FSS field activities were projected to take four (4) working days to complete. Daily briefings were conducted to discuss the expectations for job performance and to review safety aspects of the job. The survey required field activities were performed during normal working hours starting on June 3, 2022, and concluding on July 14, 2022.

The eighteen (18) systematic surface soil sample locations were marked with flags based on GPS coordinates provided by VSP.

Gamma scans were performed on 100% of the surface area of the survey unit using a Ludlum 2350-1 paired with a Model 44-10 (2 x 2) NaI detector operated in the rate-meter mode and using audio response. The probe was positioned within 2 inches to the ground and was moved at a scan speed of approximately 0.25 meters per second. No areas of elevated activity were detected on the scans. Daily, prior to and following use, each detector was subjected to an Operational Response Check in accordance with procedure ZS-RP-108-004-011, Operation of the Ludlum Model 2350-1 Data Logger, (Reference 14). The Daily Operational Response Check compared the background response and the response to check source ranges established for normal background and detector source response to ensure that the detector was working properly.

The instruments and detectors used for this survey are presented in Table 10. The instruments and detectors were verified to be properly calibrated prior to use.

[17]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Table 10 - Instruments and Detectors Instrument/Detector Type Serial # Calibration Due Date Ludlum 2350-1/Ludlum 44-10 216173 / 25062 11/02/2022 Ludlum 2350-1/Ludlum 44-10 117578 / 157372 11/04/2022 Ludlum 2350-1/Ludlum 44-10 216174 / 226936 11/02/2022 Ludlum 2350-1/Ludlum 44-10 126218 / 226943 11/04/2022 Ludlum 2350-1/Ludlum 44-10 266657 / 308037 06/15/20221 Note 1: Instrument not used past calibration due date.

In accordance with the survey design, eighteen (18) surface soil samples were collected at the designated systematic sample points. In addition, two (2) subsurface samples were collected at the randomly selected sample locations.

Two (2) samples (L1-10202D-FSGS-215-SS and L1-10202D-FSGS-216-SS) were selected for HTD radionuclide analysis.

7. SURVEY RESULTS One hundred percent (100%) of the surface of the survey unit was scanned for elevated radiation levels. Seventy-one (71) 1-meter wide scan rows, as shown on the map in Attachment 1, were marked in the field and scanned with the 2350-1/44-10 using latching mode. Readings were recorded at approximately 10-meter intervals during the scans. No elevated measurement locations were identified by surface scan. Table 11 provides an overview of the scan results.

Complete scan results are provided in Attachment 2.

Table 11 - Synopsis of Scan Results Highest Logged Scan Action Level1 # of Scan Reading Investigation Samples Area Alarms (cpm) (cpm) 1 4624 4724 0 0 2 4302 4724 0 0 3 4377 4724 0 0 4 4189 4724 0 0 5 4377 4724 0 0 6 4214 4724 0 0 7 4132 4724 0 0 8 4247 4724 0 0 9 4228 4724 0 0 10 4144 4724 0 0 11 4916 5314 0 0

[18]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Highest Logged Scan Action Level1 # of Scan Reading Investigation Samples Area Alarms (cpm) (cpm) 12 4835 5314 0 0 13 5183 5314 0 0 14 5248 5314 0 0 15 4782 5314 0 0 16 4915 5314 0 0 17 5198 5314 0 0 18 5014 5314 0 0 19 5199 5314 0 0 20 4892 5218 0 0 21 4842 5218 0 0 22 4734 5218 0 0 23 5128 5218 0 0 24 5094 5218 0 0 25 5076 5218 0 0 26 4876 5218 0 0 27 4973 5218 0 0 28 4577 4623 0 0 29 4244 4350 0 0 30 4205 4350 0 0 31 4351 4623 0 0 32 4468 4623 0 0 33 4557 4623 0 0 34 4581 4623 0 0 35 4243 4623 0 0 36 4410 4623 0 0 37 4345 4623 0 0 38 4394 4623 0 0 39 5035 5217 0 0 40 4510 5217 0 0 41 5013 5048 0 0 42 5017 5048 0 0 43 5186 5203 0 0 44 5040 5048 0 0 45 4926 5048 0 0 46 4955 5048 0 0 47 4966 5048 0 0 48 5154 5203 0 0 49 5115 5203 0 0 50 5100 5203 0 0 51 5174 5203 0 0 52 5113 5203 0 0 53 5198 5203 0 0

[19]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Highest Logged Scan Action Level1 # of Scan Reading Investigation Samples Area Alarms (cpm) (cpm) 54 5503 5690 0 0 55 5603 5690 0 0 56 5468 5690 0 0 57 5518 5690 0 0 58 5415 5690 0 0 59 5543 5690 0 0 60 5352 5527 0 0 61 5441 5527 0 0 62 5445 5679 0 0 63 5625 5679 0 0 64 5634 5679 0 0 65 5586 5672 0 0 66 5537 5544 0 0 67 5438 5544 0 0 68 5435 5544 0 0 69 5322 5544 0 0 70 5425 5505 0 0 71 5468 5505 0 0 Note 1: The action level is based on the measurement Minimum Detectable Count Rate (MDCR) plus background in accordance with the FSS plan The eighteen (18) soil samples taken for non-parametric statistical testing and two (2) subsurface soil samples were analyzed off-site by GEL Laboratories. Summaries of the sample analysis results are provided in Tables 12 and 13, respectively. The basic statistics for the systematic sample population are summarized in Table 18. The gamma spectroscopy results revealed three (3) samples with activity levels above MDC for Cs-137 and no samples with activity levels above the MDC for Co-60 or Cs-134. The concentrations for Ni-63 and Sr-90 are inferred based on the maximum ratios as specified in Table 6. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 expected to be found in off-site soil in the vicinity of the ZNPS as presented in ZionSolutions TSD 13-004, Examination of Cs-137 Global Fallout in Soils At Zion Station, (Reference 15). The complete gamma spectroscopy reports are presented in Attachment 7.

[20]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Table 12 - Summary of Gamma Spectroscopy Results for Surface Soil Samples Comprising the Statistical Sample Population Co-60(1) Cs-134(1) Cs-137(1) Ni-63(2) Sr-90(2)

MEASUREMENT ID (pCi/g) (pCi/g) (pCi/g) (pCi/g) (pCi/g)

L1-10202D-FSGS-201-SS 6.53E-03 1.51E-02 1.98E-02 1.18E+00 3.96E-05 L1-10202D-FSGS-202-SS 0.00E+00 1.80E-03 2.64E-03 0.00E+00 5.28E-06 L1-10202D-FSGS-203-SS 2.58E-03 4.91E-03 0.00E+00 4.66E-01 0.00E+00 L1-10202D-FSGS-204-SS 0.00E+00 2.23E-02 2.60E-02 0.00E+00 5.20E-05 L1-10202D-FSGS-205-SS 2.34E-02 1.78E-02 9.44E-03 4.22E+00 1.89E-05 L1-10202D-FSGS-206-SS 1.92E-02 1.63E-02 0.00E+00 3.46E+00 0.00E+00 L1-10202D-FSGS-207-SS 0.00E+00 9.91E-03 4.33E-03 0.00E+00 8.66E-06 L1-10202D-FSGS-208-SS 3.02E-03 3.28E-02 0.00E+00 5.45E-01 0.00E+00 L1-10202D-FSGS-209-SS 0.00E+00 1.43E-02 0.00E+00 0.00E+00 0.00E+00 L1-10202D-FSGS-210-SS 2.22E-02 1.76E-02 3.02E-02 4.01E+00 6.04E-05 L1-10202D-FSGS-211-SS 8.81E-03 3.72E-02 3.36E-02 1.59E+00 6.72E-05 L1-10202D-FSGS-212-SS 0.00E+00 3.41E-02 2.54E-03 0.00E+00 5.08E-06 L1-10202D-FSGS-213-SS 0.00E+00 1.23E-02 4.98E-03 0.00E+00 9.96E-06 L1-10202D-FSGS-214-SS 0.00E+00 6.16E-03 1.33E-03 0.00E+00 2.66E-06 L1-10202D-FSGS-215-SS 0.00E+00 9.88E-03 4.00E-02 0.00E+00 8.00E-05 L1-10202D-FSGS-216-SS 2.18E-02 4.22E-02 7.28E-02 3.93E+00 1.46E-04 L1-10202D-FSGS-217-SS 0.00E+00 6.23E-03 3.67E-02 0.00E+00 7.34E-05 L1-10202D-FSGS-218-SS 0.00E+00 4.95E-03 0.00E+00 0.00E+00 0.00E+00 Note: (1) Bold font indicates ROC positively detected at concentration greater than MDC.

(1) Ni-63 and Sr-90 are inferred concentrations using the maximum HTD ratio.

Table 13 - Summary of Gamma Spectroscopy Results for Subsurface Soil Samples Co-60(1) Cs-134(1) Cs-137(1) Ni-63(2) Sr-90(2)

MEASUREMENT ID (pCi/g) (pCi/g) (pCi/g) (pCi/g) (pCi/g)

L1-10202D-FSGS-211-SB 0.00E+00 8.42E-04 2.45E-02 0.00E+00 4.90E-05 L1-10202D-FSGS-216-SB 0.00E+00 0.00E+00 4.81E-02 0.00E+00 9.62E-05 Note: (1) Bold font indicates ROC positively detected at concentration greater than MDC.

(2) Ni-63 and Sr-90 are inferred concentrations using the maximum HTD ratio.

The off-site laboratory processed the two (2) samples selected for HTD ROC analysis as specified in the survey design. Samples L1-10202D-FSGS-215-SS and L1-10202D-FSGS-216-SS were selected. Only HTD radionuclides included as ROC (Ni-63 and Sr-90 for soils) were included in the analysis. All analyses met the required MDC. No HTD ROCs were positively detected at concentrations greater than MDC. Consequently, comparison of existing ratios verses the maximum ratios from Table 6 was not required.

The implementation of survey specific QC measures included the collection of one (1) sample (L1-10202D-FQGS-201-SS) for split sample analysis. The off-site laboratory analyzed the

[21]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D designated QC sample, and gamma spectroscopy results (summarized in Table 14) indicate that the concentrations in the sample were less than MDC for Cs-137, Cs-134 and Co-60. The concentrations for Ni-63 and Sr-90 are inferred based on the maximum ratios as specified in Table 6.

Table 14 - Summary of Gamma Spectroscopy Results for QC Surface Soil Sample Co-60(1) Cs-134(1) Cs-137(1) Ni-63(2) Sr-90(2)

MEASUREMENT ID (pCi/g) (pCi/g) (pCi/g) (pCi/g) (pCi/g)

L1-10202D-FQGS-201-SS 1.31E-02 0.00E+00 3.78E-03 2.36E+00 7.56E-06 Note: (1) Bold font indicates ROC positively detected at concentration greater than MDC.

(2) Ni-63 and Sr-90 are inferred concentrations using the maximum HTD ratio.

The SOF or unity rule is the mathematical test used to evaluate compliance with radiological criteria for license termination when more than one radionuclide has been determined to be potentially present. The equation for the unity rule is:

Equation 6 C1 C2 Cn

+ +............ 1 DCGL1 DCGL2 DCGLn Where: Cn = concentration of radionuclide n DCGLn = DCGL of radionuclide n.

The results of the unity rule calculation for the ROC in the systematic sample population when compared against the OpDCGLs for surface soils for survey unit 10202D are provided in Table

15. The results of the unity rule calculation for the ROC for the subsurface samples are provided in Table 16 and the results for the QC sample are presented in Table 17.

Table 15 - Sum of Fractions for Surface Soil Samples, when compared to the OpDCGLs (Systematic)

Fraction of the OpDCGLs for Surface Soils MEASUREMENT ID OpSOF Co-60 Cs-134 Cs-137 Ni-63 Sr-90 L1-10202D-FSGS-201-SS 5.99E-03 8.71E-03 5.45E-03 1.29E-03 1.28E-05 0.021 L1-10202D-FSGS-202-SS 0.00E+00 1.04E-03 7.27E-04 0.00E+00 1.71E-06 0.002 L1-10202D-FSGS-203-SS 2.36E-03 2.83E-03 0.00E+00 5.09E-04 0.00E+00 0.006 L1-10202D-FSGS-204-SS 0.00E+00 1.29E-02 7.16E-03 0.00E+00 1.68E-05 0.020 L1-10202D-FSGS-205-SS 2.14E-02 1.03E-02 2.60E-03 4.62E-03 6.10E-06 0.039 L1-10202D-FSGS-206-SS 1.76E-02 9.41E-03 0.00E+00 3.79E-03 0.00E+00 0.031 L1-10202D-FSGS-207-SS 0.00E+00 5.72E-03 1.19E-03 0.00E+00 2.80E-06 0.007 L1-10202D-FSGS-208-SS 2.77E-03 1.89E-02 0.00E+00 5.96E-04 0.00E+00 0.022 L1-10202D-FSGS-209-SS 0.00E+00 8.25E-03 0.00E+00 0.00E+00 0.00E+00 0.008 L1-10202D-FSGS-210-SS 2.03E-02 1.02E-02 8.32E-03 4.38E-03 1.95E-05 0.043 L1-10202D-FSGS-211-SS 8.08E-03 2.15E-02 9.26E-03 1.74E-03 2.17E-05 0.041

[22]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Fraction of the OpDCGLs for Surface Soils MEASUREMENT ID OpSOF Co-60 Cs-134 Cs-137 Ni-63 Sr-90 L1-10202D-FSGS-212-SS 0.00E+00 1.97E-02 7.00E-04 0.00E+00 1.64E-06 0.020 L1-10202D-FSGS-213-SS 0.00E+00 7.10E-03 1.37E-03 0.00E+00 3.22E-06 0.008 L1-10202D-FSGS-214-SS 0.00E+00 3.55E-03 3.66E-04 0.00E+00 8.59E-07 0.004 L1-10202D-FSGS-215-SS 0.00E+00 5.70E-03 1.10E-02 0.00E+00 2.58E-05 0.017 L1-10202D-FSGS-216-SS 2.00E-02 2.44E-02 2.01E-02 4.30E-03 4.70E-05 0.069 L1-10202D-FSGS-217-SS 0.00E+00 3.59E-03 1.01E-02 0.00E+00 2.37E-05 0.014 L1-10202D-FSGS-218-SS 0.00E+00 2.86E-03 0.00E+00 0.00E+00 0.00E+00 0.003 Systematic Measurements Number of Systematic Measurements = 18

  1. of Systematic Measurements with OpSOF > 1 = 0
  1. of Systematic Measurements with OpSOF > 0.1 (HTD Assessment) = 0 Max Individual Systematic Measurement OpSOF = 0.069 Mean Systematic Measurement OpSOF = 0.021 Table 16 - Sum of Fractions for Subsurface Soil Samples, when compared to the OpDCGLs Fraction of the OpDCGLs for Subsurface Soils MEASUREMENT ID OpSOF Co-60 Cs-134 Cs-137 Ni-63 Sr-90 L1-10202D-FSGS-211-SB 0.00E+00 7.41E-04 1.23E-02 0.00E+00 1.15E-04 0.013 L1-10202D-FSGS-216-SB 0.00E+00 0.00E+00 2.42E-02 0.00E+00 2.26E-04 0.024 Table 17 - Sum of Fractions for Surface Soil Samples, when compared to the OpDCGLs (QC)

Fraction of the OpDCGLs for Surface Soils MEASUREMENT ID OpSOF Co-60 Cs-134 Cs-137 Ni-63 Sr-90 L1-10202D-FQGS-201-SS 1.20E-02 0.00E+00 1.04E-03 2.59E-03 2.44E-06 0.016 Table 18 - Basic Statistical Properties of Systematic Sample Population Mean Median Max Min Std. Dev. BcDCGL Avg. SOF Avg. Dose ROC (pCi/g) (pCi/g) (pCi/g) (pCi/g) (pCi/g) (pCi/g) per ROC Per ROC Co-60 5.97E-03 0.00E+00 2.34E-02 0.00E+00 0.009 4.26 1.40E-03 3.51E-02 Cs-134 1.70E-02 1.47E-02 4.22E-02 1.80E-03 0.012 6.77 2.51E-03 6.27E-02 Cs-137 1.58E-02 4.66E-03 7.28E-02 0.00E+00 0.020 14.18 1.11E-03 2.79E-02 Ni-63 1.08E+00 0.00E+00 4.22E+00 0.00E+00 1.625 3572.1 3.02E-04 7.55E-03 Sr-90 3.16E-05 9.31E-06 1.46E-04 0.00E+00 0.000 12.09 2.61E-06 6.53E-05 The mean BcSOF for survey unit 10202D is 0.005 which equates to a dose of 0.133 mrem/yr TEDE.

The mean of all identified isotopes are less than the Consultation Triggers for Residential and Commercial/Industrial Soil Contamination depicted in Table H.1 of NUREG 1757, Vol. 1,

[23]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D (MOU Table 1). The full table is included in Attachment 3 of this Release Record.

8. QUALITY CONTROL The off-site laboratory processed one (1) split sample, L1-10202D-FQGS-201-SS, using gamma spectroscopy analysis. The data was evaluated using acceptance criteria specified in ZionSolutions procedure ZS-LT-01. Both the standard sample and QC sample did not have a positive result for Cs-137, therefore K-40 was used in the QC comparison. There was acceptable agreement when using K-40. Refer to Attachment 5 for data and quality control analysis results.
9. INVESTIGATIONS AND RESULTS No investigations were performed in survey unit 10202D.
10. REMEDIATION AND RESULTS No remediation was performed in this survey unit.
11. CHANGES FROM THE SURVEY PLAN There were no addendums to the FSS plan.
12. DATA QUALITY ASSESSMENT The DQO sample design and data were reviewed in accordance with ZionSolutions procedure ZS-LT-300-001-004, Final Status Survey Data Assessment, (Reference 16) for completeness and consistency. Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs. The sampling design had adequate power as indicated by the Retrospective Power Curve.

The analytical results of all samples were less than a SOF of one when compared to the OpDCGLs.

Although MARSSIM states that the Sign Test need not be performed in the instance that no measurements surpass the DCGL, the test was conducted to demonstrate coherence to the statistical principles of the DQO process. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results clearly demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected. The Sign Test is included in Attachment 4.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). All data was considered valid including negative values, zeros, values reported below the MDC, and values with uncertainties greater than two standard deviations. The mean and median values for each ROC were well below the respective OpDCGLs. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the unrestricted release

[24]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D criteria with adequate power as required by the DQOs.

The data for Co-60 and Cs-137 is represented graphically through a frequency plot and a quantile plot. All graphical representations are provided in Attachment 6.

13. ANOMALIES No anomalies were observed during the performance or analyses of the survey.
14. CONCLUSION Survey unit 10202D has met the DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. The EMC for soils was not needed for this survey unit and remediation was not required.

All identified ROC were used for statistical testing to determine the adequacy of the survey unit for FSS. Evaluation of the data shows that none of the ROC concentration values exceed the OpDCGL or any investigational levels; therefore, in accordance with the LTP Section 5.10, the survey unit meets the release criterion.

The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve showed that adequate power was achieved.

The mean BCSOF, when the analytical results were compared to the BCDCGLs, was 0.005, which results in a dose contribution from soil in survey unit 10202D of 0.133 mrem/yr TEDE, based on the average concentration of the ROC in samples used for non-parametric statistical sampling.

The conclusion of this Release Record is that survey unit 10202D is acceptable for unrestricted release.

15. REFERENCES
1. ZionSolutions procedure ZS-LT-300-001-005, Final Status Survey Data Reporting
2. Zion Station Restoration Project License Termination Plan
3. ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package Development
4. NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual
5. ZionSolutions procedure ZS-LT-300-001-002, Survey Unit Classification
6. Zion Station Historical Site Assessment
7. ZionSolutions TSD 11-001, Technical Support Document for Potential Radionuclides of Concern During the Decommissioning of the Zion Station
8. ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms

[25]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D

9. ZionSolutions TSD 14-011, Soil Area Factors
10. ZionSolutions TSD 17-004, Operational Derived Concentration Guideline Levels for Final Status Survey
11. ZionSolutions TSD 11-004, Ludlum Model 44-10 Detector Sensitivity
12. ZionSolutions procedure ZS-LT-01, Quality Assurance Project Plan (for Characterization and FSS)
13. ZionSolutions procedure ZS-LT-300-001-003, Isolation and Control for Final Status Survey
14. ZionSolutions procedure ZS-RP-108-004-011, Operation of the Ludlum Model 2350-1 Data Logger
15. ZionSolutions TSD 13-004, Examination of Cs-137 Global Fallout in Soils At Zion Station
16. ZionSolutions procedure ZS-LT-300-001-004, Final Status Survey Data Assessment
16. ATTACHMENTS
1. Attachment 1 - Figure and Map
2. Attachment 2 - Scan Data
3. Attachment 3 - Consultation Triggers for Residential and Commercial/Industrial Soil Contamination
4. Attachment 4 - Sign Test
5. Attachment 5 - QC Sample Assessment
6. Attachment 6 - Graphical Presentations
7. Attachment 7 - GEL Laboratories Analytical Reports

[26]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D ATTACHMENT 1 FIGURE AND MAP

[27]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Survey Unit 10202D Final Status Survey Boundaries and Systematic Sample Points

[28]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Survey Unit 10202D Final Status Survey Scan Rows

[29]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D ATTACHMENT 2 SCAN DATA

[30]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Scan Avg Action Detector Detector M2350-1 Survey Logged Scan Location Date/Time Background Level Type ID ID Unit Result Alarms (cpm) (cpm) (cpm) 44-10 226936 216174 10202D 1 6/3/2022 9:10 4624 4044 4724 No 44-10 226936 216174 10202D 1 6/3/2022 9:17 4228 4044 4724 No 44-10 226936 216174 10202D 1 6/3/2022 9:23 4298 4044 4724 No 44-10 226936 216174 10202D 2 6/3/2022 9:31 4199 4044 4724 No 44-10 226936 216174 10202D 2 6/3/2022 9:39 4302 4044 4724 No 44-10 226936 216174 10202D 2 6/3/2022 9:47 4265 4044 4724 No 44-10 226936 216174 10202D 3 6/3/2022 9:53 4377 4044 4724 No 44-10 226936 216174 10202D 3 6/3/2022 9:58 4147 4044 4724 No 44-10 226936 216174 10202D 3 6/3/2022 10:02 4126 4044 4724 No 44-10 226936 216174 10202D 4 6/3/2022 10:08 4189 4044 4724 No 44-10 226936 216174 10202D 4 6/3/2022 10:12 4119 4044 4724 No 44-10 226936 216174 10202D 4 6/3/2022 10:17 4072 4044 4724 No 44-10 226936 216174 10202D 5 6/3/2022 10:22 3957 4044 4724 No 44-10 226936 216174 10202D 5 6/3/2022 10:27 4377 4044 4724 No 44-10 226936 216174 10202D 5 6/3/2022 10:33 4037 4044 4724 No 44-10 226936 216174 10202D 6 6/3/2022 12:52 3923 4044 4724 No 44-10 226936 216174 10202D 6 6/3/2022 12:57 4214 4044 4724 No 44-10 226936 216174 10202D 6 6/3/2022 13:02 4064 4044 4724 No 44-10 226936 216174 10202D 7 6/3/2022 13:08 4132 4044 4724 No 44-10 226936 216174 10202D 7 6/3/2022 13:12 4069 4044 4724 No 44-10 226936 216174 10202D 7 6/3/2022 13:17 4061 4044 4724 No 44-10 226936 216174 10202D 8 6/3/2022 13:22 4247 4044 4724 No 44-10 226936 216174 10202D 8 6/3/2022 13:27 4200 4044 4724 No 44-10 226936 216174 10202D 8 6/3/2022 13:32 4159 4044 4724 No 44-10 226936 216174 10202D 9 6/3/2022 13:39 4011 4044 4724 No 44-10 226936 216174 10202D 9 6/3/2022 13:44 4132 4044 4724 No 44-10 226936 216174 10202D 9 6/3/2022 13:49 4228 4044 4724 No 44-10 226936 216174 10202D 10 6/3/2022 13:55 4121 4044 4724 No 44-10 226936 216174 10202D 10 6/3/2022 13:59 4144 4044 4724 No 44-10 226936 216174 10202D 10 6/3/2022 14:04 4132 4044 4724 No 44-10 25062 216173 10202D 11 6/7/2022 10:28 4916 4590 5314 No 44-10 308037 266657 10202D 11 6/7/2022 9:37 4382 3936 4606 No 44-10 308037 266657 10202D 11 6/11/2022 8:48 4487 3986 4661 No 44-10 308037 266657 10202D 11 6/11/2022 8:52 4486 3986 4661 No 44-10 25062 216173 10202D 12 6/7/2022 10:34 4835 4590 5314 No

[31]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Scan Avg Action Detector Detector M2350-1 Survey Logged Scan Location Date/Time Background Level Type ID ID Unit Result Alarms (cpm) (cpm) (cpm) 44-10 308037 266657 10202D 12 6/7/2022 9:47 4513 3936 4606 No 44-10 308037 266657 10202D 12 6/11/2022 8:58 4489 3986 4661 No 44-10 308037 266657 10202D 12 6/11/2022 9:02 4217 3986 4661 No 44-10 25062 216173 10202D 13 6/7/2022 10:40 5183 4590 5314 No 44-10 308037 266657 10202D 13 6/7/2022 9:55 3995 3936 4606 No 44-10 308037 266657 10202D 13 6/11/2022 9:07 4567 3986 4661 No 44-10 308037 266657 10202D 13 6/11/2022 9:11 4607 3986 4661 No 44-10 25062 216173 10202D 14 6/7/2022 10:46 5248 4590 5314 No 44-10 308037 266657 10202D 14 6/7/2022 10:02 4492 3936 4606 No 44-10 308037 266657 10202D 14 6/11/2022 9:16 4607 3986 4661 No 44-10 308037 266657 10202D 14 6/11/2022 9:20 4543 3986 4661 No 44-10 25062 216173 10202D 15 6/7/2022 13:56 4782 4590 5314 No 44-10 308037 266657 10202D 15 6/7/2022 10:12 4073 3936 4606 No 44-10 308037 266657 10202D 15 6/11/2022 9:25 4618 3986 4661 No 44-10 308037 266657 10202D 15 6/11/2022 9:29 4264 3986 4661 No 44-10 25062 216173 10202D 16 6/7/2022 14:06 4915 4590 5314 No 44-10 308037 266657 10202D 16 6/7/2022 10:18 4588 3936 4606 No 44-10 308037 266657 10202D 16 6/11/2022 9:34 4577 3986 4661 No 44-10 308037 266657 10202D 16 6/11/2022 9:38 4538 3986 4661 No 44-10 25062 216173 10202D 17 6/7/2022 14:12 5198 4590 5314 No 44-10 308037 266657 10202D 17 6/7/2022 10:27 4428 3936 4606 No 44-10 308037 266657 10202D 17 6/11/2022 9:42 4472 3986 4661 No 44-10 308037 266657 10202D 17 6/11/2022 9:46 4186 3986 4661 No 44-10 25062 216173 10202D 18 6/7/2022 14:19 5014 4590 5314 No 44-10 308037 266657 10202D 18 6/7/2022 10:33 4562 3936 4606 No 44-10 308037 266657 10202D 18 6/11/2022 9:52 4633 3986 4661 No 44-10 308037 266657 10202D 18 6/11/2022 9:57 4384 3986 4661 No 44-10 25062 216173 10202D 19 6/7/2022 14:28 5199 4590 5314 No 44-10 308037 266657 10202D 19 6/7/2022 10:38 4463 3936 4606 No 44-10 308037 266657 10202D 19 6/11/2022 10:02 4580 3986 4661 No 44-10 308037 266657 10202D 19 6/11/2022 10:07 4603 3986 4661 No 44-10 308037 266657 10202D 20 6/7/2022 10:42 4580 3936 4606 No 44-10 25062 216173 10202D 20 6/9/2022 8:55 4892 4417 5218 No 44-10 308037 266657 10202D 20 6/11/2022 10:22 4237 3986 4661 No 44-10 308037 266657 10202D 20 6/11/2022 10:26 4570 3986 4661 No 44-10 308037 266657 10202D 21 6/7/2022 13:54 4396 3936 4606 No

[32]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Scan Avg Action Detector Detector M2350-1 Survey Logged Scan Location Date/Time Background Level Type ID ID Unit Result Alarms (cpm) (cpm) (cpm) 44-10 25062 216173 10202D 21 6/9/2022 9:01 4842 4417 5218 No 44-10 308037 266657 10202D 21 6/11/2022 10:31 4283 3986 4661 No 44-10 308037 266657 10202D 21 6/11/2022 10:34 4640 3986 4661 No 44-10 308037 266657 10202D 22 6/7/2022 14:04 4476 3936 4606 No 44-10 25062 216173 10202D 22 6/9/2022 9:05 4734 4417 5218 No 44-10 308037 266657 10202D 22 6/11/2022 12:55 4506 3986 4661 No 44-10 308037 266657 10202D 22 6/11/2022 12:29 4580 3986 4661 No 44-10 308037 266657 10202D 23 6/7/2022 14:15 4331 3936 4606 No 44-10 25062 216173 10202D 23 6/9/2022 9:10 5128 4417 5218 No 44-10 308037 266657 10202D 23 6/11/2022 13:05 4546 3986 4661 No 44-10 308037 266657 10202D 23 6/11/2022 13:16 4493 3986 4661 No 44-10 308037 266657 10202D 24 6/7/2022 14:21 4275 3936 4606 No 44-10 25062 216173 10202D 24 6/9/2022 9:15 5094 4417 5218 No 44-10 308037 266657 10202D 24 6/11/2022 13:21 4435 3986 4661 No 44-10 308037 266657 10202D 24 6/11/2022 13:26 4517 3986 4661 No 44-10 308037 266657 10202D 25 6/7/2022 14:27 4422 3936 4606 No 44-10 25062 216173 10202D 25 6/9/2022 9:21 5076 4417 5218 No 44-10 308037 266657 10202D 25 6/11/2022 13:43 4640 3986 4661 No 44-10 308037 266657 10202D 25 6/11/2022 13:47 4572 3986 4661 No 44-10 308037 266657 10202D 26 6/7/2022 14:33 4531 3936 4606 No 44-10 25062 216173 10202D 26 6/9/2022 9:26 4876 4417 5218 No 44-10 308037 266657 10202D 26 6/11/2022 13:52 4602 3986 4661 No 44-10 308037 266657 10202D 26 6/11/2022 13:57 4502 3986 4661 No 44-10 25062 216173 10202D 27 6/9/2022 9:32 4973 4417 5218 No 44-10 308037 266657 10202D 27 6/11/2022 14:03 4524 3986 4661 No 44-10 308037 266657 10202D 27 6/11/2022 14:08 4582 3986 4661 No 44-10 226936 216174 10202D 27 7/14/2022 9:37 4333 3700 4350 No 44-10 226936 216174 10202D 28 6/9/2022 8:43 4577 3951 4623 No 44-10 226936 216174 10202D 28 6/9/2022 8:48 3950 3951 4623 No 44-10 226936 216174 10202D 28 6/10/2022 8:45 4262 3663 4310 No 44-10 226936 216174 10202D 29 6/10/2022 8:49 4150 3663 4310 No 44-10 226936 216174 10202D 29 7/14/2022 9:39 4121 3700 4350 No 44-10 226936 216174 10202D 29 7/14/2022 9:43 4222 3700 4350 No 44-10 226936 216174 10202D 29 7/14/2022 9:47 4244 3700 4350 No 44-10 226936 216174 10202D 30 6/10/2022 8:54 4185 3663 4310 No 44-10 226936 216174 10202D 30 7/14/2022 9:52 4074 3700 4350 No

[33]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Scan Avg Action Detector Detector M2350-1 Survey Logged Scan Location Date/Time Background Level Type ID ID Unit Result Alarms (cpm) (cpm) (cpm) 44-10 226936 216174 10202D 30 7/14/2022 9:56 4205 3700 4350 No 44-10 226936 216174 10202D 30 7/14/2022 9:58 3888 3700 4350 No 44-10 226936 216174 10202D 31 6/9/2022 8:53 4083 3951 4623 No 44-10 226936 216174 10202D 31 6/9/2022 8:57 4351 3951 4623 No 44-10 226936 216174 10202D 31 6/10/2022 8:59 4171 3663 4310 No 44-10 226936 216174 10202D 32 6/9/2022 9:02 4468 3951 4623 No 44-10 226936 216174 10202D 32 6/9/2022 9:07 4268 3951 4623 No 44-10 226936 216174 10202D 32 6/10/2022 9:03 3861 3663 4310 No 44-10 226936 216174 10202D 33 6/9/2022 9:12 4154 3951 4623 No 44-10 226936 216174 10202D 33 6/9/2022 9:16 4557 3951 4623 No 44-10 226936 216174 10202D 33 6/10/2022 9:08 4006 3663 4310 No 44-10 226936 216174 10202D 34 6/9/2022 9:21 4581 3951 4623 No 44-10 226936 216174 10202D 34 6/9/2022 9:25 4232 3951 4623 No 44-10 226936 216174 10202D 34 6/10/2022 9:13 4012 3663 4310 No 44-10 226936 216174 10202D 35 6/9/2022 9:29 4127 3951 4623 No 44-10 226936 216174 10202D 35 6/9/2022 9:32 4221 3951 4623 No 44-10 226936 216174 10202D 35 6/10/2022 9:17 4243 3663 4310 No 44-10 226936 216174 10202D 36 6/9/2022 9:36 4322 3951 4623 No 44-10 226936 216174 10202D 36 6/9/2022 9:40 4410 3951 4623 No 44-10 226936 216174 10202D 36 6/10/2022 9:21 4067 3663 4310 No 44-10 226936 216174 10202D 37 6/9/2022 9:44 4345 3951 4623 No 44-10 226936 216174 10202D 37 6/9/2022 9:48 4175 3951 4623 No 44-10 226936 216174 10202D 37 6/10/2022 9:25 3926 3663 4310 No 44-10 226936 216174 10202D 38 6/9/2022 9:53 4394 3951 4623 No 44-10 226936 216174 10202D 38 6/9/2022 9:57 4367 3951 4623 No 44-10 226936 216174 10202D 38 6/10/2022 9:29 4113 3663 4310 No 44-10 226936 216174 10202D 39 6/9/2022 10:02 4170 3951 4623 No 44-10 226936 216174 10202D 39 6/9/2022 10:06 4229 3951 4623 No 44-10 226936 216174 10202D 39 6/10/2022 14:41 5035 4500 5217 No 44-10 226936 216174 10202D 40 6/9/2022 10:10 4510 3951 4623 No 44-10 226936 216174 10202D 40 6/9/2022 10:15 4084 3951 4623 No 44-10 226936 216174 10202D 40 6/10/2022 15:05 4355 4500 5217 No 44-10 157372 117578 10202D 41 6/7/2022 10:11 4798 4344 5048 No 44-10 157372 117578 10202D 41 6/7/2022 10:14 4886 4344 5048 No 44-10 157372 117578 10202D 41 6/7/2022 10:20 5013 4344 5048 No 44-10 157372 117578 10202D 42 6/7/2022 10:28 4890 4344 5048 No

[34]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Scan Avg Action Detector Detector M2350-1 Survey Logged Scan Location Date/Time Background Level Type ID ID Unit Result Alarms (cpm) (cpm) (cpm) 44-10 157372 117578 10202D 42 6/7/2022 10:32 5017 4344 5048 No 44-10 157372 117578 10202D 42 6/7/2022 10:34 4859 4344 5048 No 44-10 157372 117578 10202D 43 6/7/2022 10:49 4830 4344 5048 No 44-10 157372 117578 10202D 43 6/7/2022 10:52 4930 4344 5048 No 44-10 157372 117578 10202D 43 6/9/2022 8:44 5186 4487 5203 No 44-10 157372 117578 10202D 44 6/7/2022 13:28 5012 4344 5048 No 44-10 157372 117578 10202D 44 6/7/2022 13:34 5040 4344 5048 No 44-10 157372 117578 10202D 44 6/7/2022 13:43 4945 4344 5048 No 44-10 157372 117578 10202D 45 6/7/2022 13:51 4781 4344 5048 No 44-10 157372 117578 10202D 45 6/7/2022 13:57 4890 4344 5048 No 44-10 157372 117578 10202D 45 6/7/2022 13:59 4926 4344 5048 No 44-10 157372 117578 10202D 46 6/7/2022 14:03 4890 4344 5048 No 44-10 157372 117578 10202D 46 6/7/2022 14:09 4870 4344 5048 No 44-10 157372 117578 10202D 46 6/7/2022 14:17 4955 4344 5048 No 44-10 157372 117578 10202D 47 6/7/2022 14:29 4966 4344 5048 No 44-10 157372 117578 10202D 47 6/7/2022 14:33 4778 4344 5048 No 44-10 157372 117578 10202D 47 6/7/2022 14:36 4871 4344 5048 No 44-10 157372 117578 10202D 48 6/9/2022 8:50 5001 4487 5203 No 44-10 157372 117578 10202D 48 6/9/2022 8:55 4958 4487 5203 No 44-10 157372 117578 10202D 48 6/9/2022 9:00 5154 4487 5203 No 44-10 157372 117578 10202D 49 6/9/2022 9:06 5115 4487 5203 No 44-10 157372 117578 10202D 49 6/9/2022 9:11 4948 4487 5203 No 44-10 157372 117578 10202D 49 6/9/2022 9:15 4933 4487 5203 No 44-10 157372 117578 10202D 50 6/9/2022 9:18 4978 4487 5203 No 44-10 157372 117578 10202D 50 6/9/2022 9:24 5100 4487 5203 No 44-10 157372 117578 10202D 50 6/9/2022 9:31 5070 4487 5203 No 44-10 157372 117578 10202D 51 6/9/2022 9:39 5017 4487 5203 No 44-10 157372 117578 10202D 51 6/9/2022 9:45 5084 4487 5203 No 44-10 157372 117578 10202D 51 6/9/2022 9:48 5174 4487 5203 No 44-10 157372 117578 10202D 52 6/9/2022 9:53 4969 4487 5203 No 44-10 157372 117578 10202D 52 6/9/2022 10:00 5092 4487 5203 No 44-10 157372 117578 10202D 52 6/9/2022 10:10 5113 4487 5203 No 44-10 157372 117578 10202D 53 6/9/2022 10:16 5174 4487 5203 No 44-10 157372 117578 10202D 53 6/9/2022 10:21 5198 4487 5203 No 44-10 157372 117578 10202D 53 6/9/2022 10:24 4931 4487 5203 No 44-10 157372 117578 10202D 54 6/9/2022 10:29 5081 4487 5203 No

[35]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Scan Avg Action Detector Detector M2350-1 Survey Logged Scan Location Date/Time Background Level Type ID ID Unit Result Alarms (cpm) (cpm) (cpm) 44-10 157372 117578 10202D 54 6/9/2022 10:34 5144 4487 5203 No 44-10 157372 117578 10202D 54 6/9/2022 13:02 5190 4487 5203 No 44-10 157372 117578 10202D 54 6/9/2022 13:38 5503 4939 5690 No 44-10 157372 117578 10202D 55 6/9/2022 13:44 5603 4939 5690 No 44-10 157372 117578 10202D 55 6/9/2022 13:50 5180 4939 5690 No 44-10 157372 117578 10202D 55 6/9/2022 13:52 5022 4939 5690 No 44-10 157372 117578 10202D 56 6/9/2022 13:56 5129 4939 5690 No 44-10 157372 117578 10202D 56 6/9/2022 14:01 4804 4939 5690 No 44-10 157372 117578 10202D 56 6/9/2022 14:06 5468 4939 5690 No 44-10 157372 117578 10202D 57 6/9/2022 14:17 5457 4939 5690 No 44-10 157372 117578 10202D 57 6/9/2022 14:22 5022 4939 5690 No 44-10 157372 117578 10202D 57 6/9/2022 14:25 5518 4939 5690 No 44-10 157372 117578 10202D 58 6/9/2022 14:29 5188 4939 5690 No 44-10 157372 117578 10202D 58 6/9/2022 14:35 5000 4939 5690 No 44-10 157372 117578 10202D 58 6/9/2022 14:40 5415 4939 5690 No 44-10 157372 117578 10202D 59 6/9/2022 14:46 5543 4939 5690 No 44-10 157372 117578 10202D 59 6/9/2022 14:52 5286 4939 5690 No 44-10 157372 117578 10202D 59 6/9/2022 14:55 4945 4939 5690 No 44-10 157372 117578 10202D 59 6/10/2022 9:00 5435 4787 5527 No 44-10 157372 117578 10202D 59 6/10/2022 9:05 5036 4787 5527 No 44-10 157372 117578 10202D 59 6/10/2022 9:07 5181 4787 5527 No 44-10 157372 117578 10202D 60 6/10/2022 9:10 5330 4787 5527 No 44-10 157372 117578 10202D 60 6/10/2022 9:15 5066 4787 5527 No 44-10 157372 117578 10202D 60 6/10/2022 9:21 5352 4787 5527 No 44-10 157372 117578 10202D 61 6/10/2022 9:27 5441 4787 5527 No 44-10 157372 117578 10202D 61 6/10/2022 9:32 5149 4787 5527 No 44-10 157372 117578 10202D 61 6/10/2022 9:34 5114 4787 5527 No 44-10 157372 117578 10202D 62 6/10/2022 9:36 5149 4787 5527 No 44-10 157372 117578 10202D 62 6/10/2022 9:41 5298 4787 5527 No 44-10 157372 117578 10202D 62 6/10/2022 9:48 5431 4787 5527 No 44-10 157372 117578 10202D 62 6/10/2022 10:20 5445 4929 5679 No 44-10 157372 117578 10202D 63 6/10/2022 10:25 5625 4929 5679 No 44-10 157372 117578 10202D 63 6/10/2022 10:30 5378 4929 5679 No 44-10 157372 117578 10202D 63 6/10/2022 10:32 5184 4929 5679 No 44-10 157372 117578 10202D 64 6/10/2022 10:34 5496 4929 5679 No 44-10 157372 117578 10202D 64 6/10/2022 10:38 5081 4929 5679 No

[36]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Scan Avg Action Detector Detector M2350-1 Survey Logged Scan Location Date/Time Background Level Type ID ID Unit Result Alarms (cpm) (cpm) (cpm) 44-10 157372 117578 10202D 64 6/10/2022 10:43 5634 4929 5679 No 44-10 226936 216174 10202D 65 7/14/2022 10:28 4184 3858 4522 No 44-10 226936 216174 10202D 65 7/14/2022 10:29 3912 3858 4522 No 44-10 226936 216174 10202D 65 7/14/2022 10:43 5586 4922 5672 No 44-10 25062 216173 10202D 66 6/10/2022 9:26 5537 4803 5544 No 44-10 25062 216173 10202D 66 6/10/2022 9:31 5155 4803 5544 No 44-10 25062 216173 10202D 66 6/10/2022 9:32 5084 4803 5544 No 44-10 25062 216173 10202D 67 6/10/2022 9:37 5438 4803 5544 No 44-10 25062 216173 10202D 67 6/10/2022 9:42 5331 4803 5544 No 44-10 25062 216173 10202D 67 6/10/2022 9:49 5427 4803 5544 No 44-10 25062 216173 10202D 68 6/10/2022 9:56 5435 4803 5544 No 44-10 25062 216173 10202D 68 6/10/2022 9:59 5235 4803 5544 No 44-10 25062 216173 10202D 68 6/10/2022 10:01 5026 4803 5544 No 44-10 25062 216173 10202D 69 6/10/2022 10:04 5040 4803 5544 No 44-10 25062 216173 10202D 69 6/10/2022 10:08 5322 4803 5544 No 44-10 25062 216173 10202D 69 6/10/2022 10:12 5088 4803 5544 No 44-10 226943 126218 10202D 70 6/13/2022 10:15 5425 4767 5505 No 44-10 226943 126218 10202D 70 6/13/2022 10:19 4977 4767 5505 No 44-10 226943 126218 10202D 70 6/13/2022 10:21 4787 4767 5505 No 44-10 226943 126218 10202D 71 6/13/2022 10:23 5059 4767 5505 No 44-10 226943 126218 10202D 71 6/13/2022 10:27 5468 4767 5505 No 44-10 226943 126218 10202D 71 6/13/2022 10:31 5415 4767 5505 No 44-10 226943 126218 10202D 10 Q 7/14/2022 10:37 4802 4137 4824 No 44-10 226943 126218 10202D 31 Q 7/14/2022 10:34 4579 4137 4824 No 44-10 226943 126218 10202D 32 Q 7/14/2022 10:40 4773 4137 4824 No 44-10 226943 126218 10202D 33 Q 7/14/2022 10:45 4782 4137 4824 No 44-10 226943 126218 10202D 52 Q 7/14/2022 11:05 4991 4343 5048 No 44-10 226943 126218 10202D 53 Q 7/14/2022 11:09 4958 4343 5048 No 44-10 226943 126218 10202D 54 Q 7/14/2022 11:13 4920 4343 5048 No 44-10 226943 126218 10202D 6Q 7/14/2022 10:16 4532 4137 4824 No 44-10 226943 126218 10202D 7Q 7/14/2022 10:19 4538 4137 4824 No 44-10 226943 126218 10202D 8Q 7/14/2022 10:22 4410 4137 4824 No 44-10 226943 126218 10202D 9Q 7/14/2022 10:25 4721 4137 4824 No

[37]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D ATTACHMENT 3 CONSULTATION TRIGGERS FOR RESIDENTIAL AND COMMERCIAL/INDUSTRIAL SOIL CONTAMINATION

[38]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D

[39]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D ATTACHMENT 4 SIGN TEST

[40]

Digitally signed by Robert F Yetter III Robert F Yetter III DN: C=US, O=EnergySolutions, CN=Robert F Yetter III, E=rfyetteriii@energysolutions.com Reason: I am the author of this document Location: your signing location here Date: 2022-08-17 18:00:16 Foxit PhantomPDF Version: 9.7.0

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D ATTACHMENT 5 QC SAMPLE ASSESSMENT

[42]

Digitally signed by Robert F Yetter III Robert F DN: C=US, O=EnergySolutions, CN=Robert F Yetter III, E=rfyetteriii@energysolutions.com Reason: I am the author of this document Yetter III Location: your signing location here Date: 2022-08-17 17:59:56 Foxit PhantomPDF Version: 9.7.0

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D ATTACHMENT 6 GRAPHICAL PRESENTATIONS

[44]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Posting Plot

[45]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D QUANTILE PLOT FOR Co-60 Survey Unit: 10202D Survey Unit Name: IRSF/Fire Training Area Mean: 5.97E-03 pCi/g Quantile Plot For Co-60 2.50E-02 2.00E-02 Concentration (pCi/g) 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0% 20% 40% 60% 80% 100%

Percentage

[46]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D QUANTILE PLOT FOR Cs-137 Survey Unit: 10202D Survey Unit Name: IRSF/Fire Training Area Mean: 1.58E-02 pCi/g Quantile Plot For Cs-137 8.00E-02 7.00E-02 Concentration (pCi/g) 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0% 20% 40% 60% 80% 100%

Percentage

[47]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D HISTOGRAM FOR Co-60 Survey Unit: 10202D Survey Unit Name: IRSF/Fire Training Area Mean: 5.97E-03 pCi/g Median: 0.00E+00 pCi/g ST DEV: 0.009 Skew: 1.239 Observation Observation Upper Value Frequency  %

3.90E-03 12 67%

7.80E-03 1 6%

1.17E-02 1 6%

1.56E-02 0 0%

1.95E-02 1 6%

2.34E-02 3 17%

TOTAL 18 100%

Frequency Plot For Co-60 12 12 10 Frequency 8

6 4 3 2 1 1 1 0

0 3.90E-03 7.80E-03 1.17E-02 1.56E-02 1.95E-02 2.34E-02 Upper End Value (pCi/g)

[48]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D HISTOGRAM FOR Cs-137 Survey Unit: 10202D Survey Unit Name: IRSF/Fire Training Area Mean: 1.58E-02 pCi/g Median: 4.66E-03 pCi/g ST DEV: 0.020 Skew: 1.485 Observation Observation Upper Value Frequency  %

1.21E-02 11 61%

2.43E-02 1 6%

3.64E-02 3 17%

4.85E-02 2 11%

6.07E-02 0 0%

7.28E-02 1 6%

TOTAL 18 100%

Frequency Plot For Cs-137 11 10 8

Frequency 6

4 3 2

2 1 1 0

0 1.21E-02 2.43E-02 3.64E-02 4.85E-02 6.07E-02 7.28E-02 Upper End Value (pCi/g)

[49]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D Prospective and Retrospective Power Curves for Survey Unit 10202D

[50]

FSS RELEASE RECORD - REV. 1 IRSF/FIRE TRAINING AREA SURVEY UNIT 10202D ATTACHMENT 7 GEL LABORATORIES ANALYTICAL REPORTS

[51]

August 10, 2022 Mr. Gerry Wood Zion Solutions 100 Shiloh Blvd.

Zion, Illinois 60099 Re: Zion Solutions Work Order: 587450

Dear Mr. Wood:

GEL Laboratories, LLC (GEL) appreciates the opportunity to provide the enclosed analytical results for the sample(s) we received on April 07, 2022, July 06, 2022, July 11, 2022, June 09, 2022 and June 30, 2022. This original data report has been prepared and reviewed in accordance with GELs standard operating procedures.

Test results for NELAP or ISO 17025 accredited tests are verified to meet the requirements of those standards, with any exceptions noted. The results reported relate only to the items tested and to the sample as received by the laboratory. These results may not be reproduced except as full reports without approval by the laboratory.

Copies of GELs accreditations and certifications can be found on our website at www.gel.com.

Our policy is to provide high quality, personalized analytical services to enable you to meet your analytical needs on time every time. We trust that you will find everything in order and to your satisfaction. If you have any questions, please do not hesitate to call me at (843) 556-8171, ext. 1605.

Sincerely, PM_SIGN_HERE Zachary Worsham Project Manager Purchase Order: 702793 Enclosures Page 1 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Report for ENRG080 Zion Solutions (702793)

Client SDG: 587450 GEL Work Order: 587450 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a Tracer compound
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.

UI Gamma SpectroscopyUncertain identification Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

The designation ND, if present, appears in the result column when the analyte concentration is not detected above the limit as defined in the U qualifier above.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Zachary Worsham.

Reviewed by USER_SIGN_HERE Page 2 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10201C-FSGS-211-SS Project: ENRG08001 Sample ID: 587450001 Client ID: ENRG080 Matrix: Soil Collect Date: 06-JUN-22 Receive Date: 09-JUN-22 Collector: Client Moisture: 7.85%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.238 +/-0.192 0.384 +/-0.221 pCi/g RXF2 07/29/22 0525 2295332 1 Bismuth-211 U 0.285 +/-0.933 0.344 +/-0.937 pCi/g Bismuth-212 U 0.268 +/-0.635 1.09 +/-0.647 pCi/g Bismuth-214 UI 0.000 +/-0.165 0.244 +/-0.229 pCi/g Cesium-134 U 0.00983 +/-0.0363 0.0740 +/-0.0366 0.173 pCi/g Cesium-137 0.0931 +/-0.0758 0.0722 +/-0.0762 0.363 pCi/g Cobalt-60 U 0.0144 +/-0.0395 0.0883 +/-0.0400 0.109 pCi/g Europium-152 U 0.0370 +/-0.0874 0.178 +/-0.0890 0.869 pCi/g Europium-154 U 0.0266 +/-0.103 0.222 +/-0.104 0.799 pCi/g Lead-212 0.375 +/-0.0992 0.0971 +/-0.103 pCi/g Lead-214 0.361 +/-0.195 0.220 +/-0.198 pCi/g Potassium-40 8.11 +/-1.28 0.779 +/-1.48 pCi/g Thallium-208 0.118 +/-0.0588 0.0694 +/-0.0598 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.00507 +/-0.0115 0.0202 +/-0.0115 0.0425 pCi/g KP1 08/03/22 1826 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 3.98 +/-6.71 11.4 +/-6.75 19.5 pCi/g TXJ1 08/04/22 1638 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 06/10/22 1300 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 71.7 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 80.2 (25%-125%)

Page 3 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10201C-FSGS-211-SS Project: ENRG08001 Sample ID: 587450001 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 4 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10201C-FSGS-212-SS Project: ENRG08001 Sample ID: 587450002 Client ID: ENRG080 Matrix: Soil Collect Date: 06-JUN-22 Receive Date: 09-JUN-22 Collector: Client Moisture: 7.53%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.442 +/-0.286 0.454 +/-0.351 pCi/g RXF2 07/29/22 0727 2295332 1 Bismuth-211 UI 0.000 +/-0.378 0.568 +/-0.621 pCi/g Bismuth-212 U 0.403 +/-0.663 1.18 +/-0.688 pCi/g Bismuth-214 0.428 +/-0.183 0.0981 +/-0.187 pCi/g Cesium-134 U 0.0106 +/-0.0421 0.0833 +/-0.0424 0.173 pCi/g Cesium-137 UI 0.000 +/-0.0866 0.0672 +/-0.0870 0.363 pCi/g Cobalt-60 U -0.0325 +/-0.0284 0.0447 +/-0.0321 0.109 pCi/g Europium-152 U 0.00425 +/-0.0790 0.158 +/-0.0791 0.869 pCi/g Europium-154 U 0.0161 +/-0.116 0.239 +/-0.116 0.799 pCi/g Lead-212 0.337 +/-0.119 0.100 +/-0.122 pCi/g Lead-214 0.389 +/-0.137 0.0976 +/-0.141 pCi/g Potassium-40 8.12 +/-1.27 0.577 +/-1.47 pCi/g Thallium-208 0.188 +/-0.0881 0.0522 +/-0.0897 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U 0.0236 +/-0.0178 0.0296 +/-0.0183 0.0425 pCi/g KP1 08/03/22 1826 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 5.22 +/-6.47 10.9 +/-6.54 19.5 pCi/g TXJ1 08/04/22 1709 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 06/10/22 1300 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 67.1 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 81 (25%-125%)

Page 5 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10201C-FSGS-212-SS Project: ENRG08001 Sample ID: 587450002 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 6 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10201D-FSGS-205-SS Project: ENRG08001 Sample ID: 587450003 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 9.07%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.168 +/-0.123 0.126 +/-0.124 pCi/g MJH1 07/28/22 1624 2295333 1 Bismuth-211 UI 0.000 +/-0.249 0.225 +/-0.254 pCi/g Bismuth-212 U -0.175 +/-0.320 0.568 +/-0.330 pCi/g Bismuth-214 0.210 +/-0.0894 0.0778 +/-0.0914 pCi/g Cesium-134 U 0.0421 +/-0.0461 0.0653 +/-0.0500 0.173 pCi/g Cesium-137 U 0.0118 +/-0.0392 0.0399 +/-0.0392 0.363 pCi/g Cobalt-60 U -0.00480 +/-0.0239 0.0472 +/-0.0240 0.109 pCi/g Europium-152 U 0.000947 +/-0.0485 0.0998 +/-0.0485 0.869 pCi/g Europium-154 U 0.00908 +/-0.0586 0.130 +/-0.0588 0.799 pCi/g Lead-212 0.287 +/-0.0691 0.0550 +/-0.0731 pCi/g Lead-214 0.215 +/-0.0902 0.144 +/-0.134 pCi/g Potassium-40 4.54 +/-0.854 0.635 +/-0.947 pCi/g Thallium-208 U 0.0192 +/-0.0412 0.0370 +/-0.0412 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.0233 +/-0.0114 0.0212 +/-0.0114 0.0425 pCi/g KP1 08/03/22 1826 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 0.555 +/-6.01 10.3 +/-6.01 19.5 pCi/g TXJ1 08/04/22 1740 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 06/30/22 1512 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 74 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 88.6 (25%-125%)

Page 7 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10201D-FSGS-205-SS Project: ENRG08001 Sample ID: 587450003 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 8 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10201D-FSGS-213-SS Project: ENRG08001 Sample ID: 587450004 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 5.74%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.345 +/-0.187 0.244 +/-0.190 pCi/g MJH1 07/28/22 1624 2295333 1 Bismuth-211 U 0.131 +/-0.620 0.247 +/-0.631 pCi/g Bismuth-212 U 0.131 +/-0.353 0.763 +/-0.358 pCi/g Bismuth-214 0.334 +/-0.127 0.102 +/-0.131 pCi/g Cesium-134 U 0.0108 +/-0.0332 0.0685 +/-0.0336 0.173 pCi/g Cesium-137 U 0.0376 +/-0.0628 0.0495 +/-0.0629 0.363 pCi/g Cobalt-60 U -0.00623 +/-0.0249 0.0514 +/-0.0251 0.109 pCi/g Europium-152 U 0.0418 +/-0.0677 0.136 +/-0.0704 0.869 pCi/g Europium-154 U -0.0207 +/-0.0929 0.186 +/-0.0934 0.799 pCi/g Lead-212 0.348 +/-0.0854 0.0653 +/-0.0898 pCi/g Lead-214 0.449 +/-0.134 0.213 +/-0.138 pCi/g Potassium-40 8.33 +/-1.16 0.307 +/-1.37 pCi/g Thallium-208 0.0764 +/-0.0484 0.0305 +/-0.0489 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.0214 +/-0.0221 0.0390 +/-0.0221 0.0425 pCi/g KP1 08/03/22 1826 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U -1.41 +/-8.19 14.2 +/-8.19 19.5 pCi/g TXJ1 08/04/22 1810 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 06/30/22 1512 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 48.6 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 59.8 (25%-125%)

Page 9 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10201D-FSGS-213-SS Project: ENRG08001 Sample ID: 587450004 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 10 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202C-FSGS-204-SS Project: ENRG08001 Sample ID: 587450005 Client ID: ENRG080 Matrix: Soil Collect Date: 15-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 4.13%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.350 +/-0.195 0.370 +/-0.253 pCi/g MJH1 07/28/22 1625 2295333 1 Bismuth-211 UI 0.000 +/-0.331 0.438 +/-0.478 pCi/g Bismuth-212 UI 0.000 +/-0.879 0.776 +/-0.884 pCi/g Bismuth-214 0.355 +/-0.121 0.0987 +/-0.125 pCi/g Cesium-134 U 0.00454 +/-0.0298 0.0600 +/-0.0298 0.173 pCi/g Cesium-137 U 0.0355 +/-0.0380 0.0504 +/-0.0381 0.363 pCi/g Cobalt-60 U -0.0135 +/-0.0297 0.0559 +/-0.0303 0.109 pCi/g Europium-152 U 0.0407 +/-0.0693 0.147 +/-0.0718 0.869 pCi/g Europium-154 U -0.0136 +/-0.0859 0.173 +/-0.0861 0.799 pCi/g Lead-212 0.345 +/-0.0798 0.0618 +/-0.0849 pCi/g Lead-214 0.273 +/-0.120 0.0948 +/-0.122 pCi/g Potassium-40 10.2 +/-1.27 0.362 +/-1.58 pCi/g Thallium-208 0.0954 +/-0.0573 0.0425 +/-0.0579 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.0594 +/-0.0169 0.0322 +/-0.0169 0.0425 pCi/g KP1 08/03/22 1826 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 2.92 +/-7.01 11.9 +/-7.03 19.5 pCi/g TXJ1 08/04/22 1841 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 06/30/22 1505 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 57.8 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 74.8 (25%-125%)

Page 11 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202C-FSGS-204-SS Project: ENRG08001 Sample ID: 587450005 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 12 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202C-FSGS-211-SS Project: ENRG08001 Sample ID: 587450006 Client ID: ENRG080 Matrix: Soil Collect Date: 15-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 3.92%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.200 +/-0.235 0.219 +/-0.236 pCi/g MJH1 07/28/22 1627 2295333 1 Bismuth-211 UI 0.000 +/-0.316 0.494 +/-0.600 pCi/g Bismuth-212 U 0.125 +/-0.407 0.841 +/-0.411 pCi/g Bismuth-214 0.291 +/-0.133 0.112 +/-0.135 pCi/g Cesium-134 U 0.0223 +/-0.0227 0.0574 +/-0.0249 0.173 pCi/g Cesium-137 U 0.0450 +/-0.0346 0.0788 +/-0.0403 0.363 pCi/g Cobalt-60 U 0.00544 +/-0.0278 0.0637 +/-0.0279 0.109 pCi/g Europium-152 U -0.0292 +/-0.0767 0.134 +/-0.0779 0.869 pCi/g Europium-154 U -0.00114 +/-0.0993 0.206 +/-0.0993 0.799 pCi/g Lead-212 0.313 +/-0.104 0.0949 +/-0.108 pCi/g Lead-214 0.403 +/-0.115 0.0727 +/-0.120 pCi/g Potassium-40 9.89 +/-1.36 0.355 +/-1.67 pCi/g Thallium-208 U 0.0285 +/-0.0631 0.0575 +/-0.0631 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.0249 +/-0.0167 0.0297 +/-0.0167 0.0425 pCi/g KP1 08/03/22 1826 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U -0.0700 +/-6.67 11.5 +/-6.67 19.5 pCi/g TXJ1 08/04/22 1912 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 06/30/22 1505 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 74 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 82.4 (25%-125%)

Page 13 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202C-FSGS-211-SS Project: ENRG08001 Sample ID: 587450006 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 14 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-216-SS Project: ENRG08001 Sample ID: 587450007 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 7.73%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.465 +/-0.149 0.0977 +/-0.155 pCi/g MJH1 07/28/22 1638 2295333 1 Bismuth-211 UI 0.000 +/-0.384 0.553 +/-0.628 pCi/g Bismuth-212 U 0.0658 +/-0.400 0.807 +/-0.401 pCi/g Bismuth-214 0.373 +/-0.127 0.0855 +/-0.131 pCi/g Cesium-134 U 0.00491 +/-0.0269 0.0550 +/-0.0270 0.173 pCi/g Cesium-137 0.0742 +/-0.0484 0.0527 +/-0.0488 0.363 pCi/g Cobalt-60 U -0.0157 +/-0.0260 0.0488 +/-0.0270 0.109 pCi/g Europium-152 U 0.0358 +/-0.0598 0.130 +/-0.0620 0.869 pCi/g Europium-154 U 0.0581 +/-0.0879 0.201 +/-0.0918 0.799 pCi/g Lead-212 0.305 +/-0.0912 0.0840 +/-0.0946 pCi/g Lead-214 0.393 +/-0.139 0.0869 +/-0.143 pCi/g Potassium-40 8.74 +/-1.15 0.568 +/-1.42 pCi/g Thallium-208 0.134 +/-0.0618 0.0424 +/-0.0629 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.0217 +/-0.0191 0.0344 +/-0.0191 0.0425 pCi/g KP1 08/03/22 1826 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 3.55 +/-6.60 11.2 +/-6.63 19.5 pCi/g TXJ1 08/04/22 1943 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 06/30/22 1501 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 46.2 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 81 (25%-125%)

Page 15 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-216-SS Project: ENRG08001 Sample ID: 587450007 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 16 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-215-SS Project: ENRG08001 Sample ID: 587450008 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 6.29%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.435 +/-0.224 0.193 +/-0.227 pCi/g MJH1 07/28/22 1659 2295333 1 Bismuth-211 UI 0.000 +/-0.414 0.576 +/-0.647 pCi/g Bismuth-212 UI 0.000 +/-0.516 0.639 +/-0.527 pCi/g Bismuth-214 0.391 +/-0.115 0.0795 +/-0.120 pCi/g Cesium-134 U 0.0119 +/-0.0310 0.0658 +/-0.0315 0.173 pCi/g Cesium-137 U 0.0166 +/-0.0289 0.0623 +/-0.0299 0.363 pCi/g Cobalt-60 U 0.0186 +/-0.0223 0.0613 +/-0.0239 0.109 pCi/g Europium-152 U 0.00573 +/-0.0620 0.121 +/-0.0621 0.869 pCi/g Europium-154 U -0.0260 +/-0.0771 0.151 +/-0.0780 0.799 pCi/g Lead-212 0.258 +/-0.0848 0.0633 +/-0.0874 pCi/g Lead-214 0.394 +/-0.150 0.0986 +/-0.154 pCi/g Potassium-40 9.41 +/-1.32 0.662 +/-1.60 pCi/g Thallium-208 0.110 +/-0.0519 0.0454 +/-0.0527 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U 0.0154 +/-0.0198 0.0334 +/-0.0200 0.0425 pCi/g KP1 08/03/22 1826 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 2.64 +/-5.85 9.94 +/-5.87 19.5 pCi/g TXJ1 08/04/22 2014 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 06/30/22 1501 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 67.1 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 83.3 (25%-125%)

Page 17 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-215-SS Project: ENRG08001 Sample ID: 587450008 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 18 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12201D-FSGS-309-SS Project: ENRG08001 Sample ID: 587450009 Client ID: ENRG080 Matrix: Soil Collect Date: 27-JUN-22 Receive Date: 06-JUL-22 Collector: Client Moisture: 1.55%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.358 +/-0.142 0.128 +/-0.147 pCi/g MJH1 07/28/22 1659 2295333 1 Bismuth-211 UI 0.000 +/-0.570 0.247 +/-0.577 pCi/g Bismuth-212 UI 0.000 +/-0.383 0.457 +/-0.390 pCi/g Bismuth-214 0.225 +/-0.109 0.0895 +/-0.110 pCi/g Cesium-134 U 0.0168 +/-0.0255 0.0556 +/-0.0266 0.173 pCi/g Cesium-137 0.0718 +/-0.0272 0.0348 +/-0.0279 0.363 pCi/g Cobalt-60 U -0.00766 +/-0.0301 0.0582 +/-0.0303 0.109 pCi/g Europium-152 U -0.0563 +/-0.0514 0.0907 +/-0.0575 0.869 pCi/g Europium-154 U 0.0972 +/-0.0960 0.207 +/-0.106 0.799 pCi/g Lead-212 0.215 +/-0.0912 0.0659 +/-0.0928 pCi/g Lead-214 0.384 +/-0.122 0.185 +/-0.126 pCi/g Potassium-40 10.2 +/-1.21 0.395 +/-1.53 pCi/g Thallium-208 0.0838 +/-0.0589 0.0440 +/-0.0594 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.0227 +/-0.0175 0.0310 +/-0.0175 0.0425 pCi/g KP1 08/03/22 1826 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 0.210 +/-8.00 13.8 +/-8.00 19.5 pCi/g TXJ1 08/04/22 2044 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 07/06/22 1153 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 71.7 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 64.7 (25%-125%)

Page 19 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12201D-FSGS-309-SS Project: ENRG08001 Sample ID: 587450009 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 20 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12201D-FSGS-315-SS Project: ENRG08001 Sample ID: 587450010 Client ID: ENRG080 Matrix: Soil Collect Date: 27-JUN-22 Receive Date: 06-JUL-22 Collector: Client Moisture: 2.43%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.335 +/-0.202 0.378 +/-0.254 pCi/g MJH1 07/28/22 1703 2295333 1 Bismuth-211 UI 0.000 +/-0.342 0.512 +/-0.542 pCi/g Bismuth-212 U 0.152 +/-0.417 0.849 +/-0.422 pCi/g Bismuth-214 0.201 +/-0.117 0.0966 +/-0.119 pCi/g Cesium-134 U 0.00482 +/-0.0330 0.0685 +/-0.0331 0.173 pCi/g Cesium-137 0.104 +/-0.0458 0.0521 +/-0.0467 0.363 pCi/g Cobalt-60 U 0.0100 +/-0.0354 0.0754 +/-0.0357 0.109 pCi/g Europium-152 U 0.00131 +/-0.0686 0.127 +/-0.0686 0.869 pCi/g Europium-154 U -0.00217 +/-0.0967 0.175 +/-0.0967 0.799 pCi/g Lead-212 0.340 +/-0.0746 0.0705 +/-0.0797 pCi/g Lead-214 0.333 +/-0.124 0.0905 +/-0.127 pCi/g Potassium-40 8.68 +/-1.20 0.487 +/-1.47 pCi/g Thallium-208 0.0984 +/-0.0445 0.0393 +/-0.0453 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U 0.0213 +/-0.0208 0.0349 +/-0.0212 0.0425 pCi/g KP1 08/03/22 1826 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U -0.168 +/-8.02 13.8 +/-8.02 19.5 pCi/g TXJ1 08/04/22 2115 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 07/06/22 1153 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 50.9 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 64.7 (25%-125%)

Page 21 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12201D-FSGS-315-SS Project: ENRG08001 Sample ID: 587450010 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 22 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12201E-FSGS-207-SS Project: ENRG08001 Sample ID: 587450011 Client ID: ENRG080 Matrix: Soil Collect Date: 29-JUN-22 Receive Date: 11-JUL-22 Collector: Client Moisture: 2.27%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.173 +/-0.151 0.346 +/-0.171 pCi/g MJH1 07/28/22 1704 2295333 1 Bismuth-211 U 0.188 +/-0.566 0.227 +/-0.572 pCi/g Bismuth-212 U 0.206 +/-0.382 0.836 +/-0.393 pCi/g Bismuth-214 UI 0.000 +/-0.111 0.182 +/-0.163 pCi/g Cesium-134 U 0.0129 +/-0.0346 0.0726 +/-0.0351 0.173 pCi/g Cesium-137 U 0.0133 +/-0.0251 0.0565 +/-0.0259 0.363 pCi/g Cobalt-60 U -0.00902 +/-0.0240 0.0471 +/-0.0243 0.109 pCi/g Europium-152 U -0.0197 +/-0.0647 0.113 +/-0.0654 0.869 pCi/g Europium-154 U 0.0231 +/-0.110 0.232 +/-0.110 0.799 pCi/g Lead-212 0.203 +/-0.0946 0.0630 +/-0.0962 pCi/g Lead-214 0.310 +/-0.108 0.163 +/-0.111 pCi/g Potassium-40 9.59 +/-1.33 0.462 +/-1.56 pCi/g Thallium-208 0.0682 +/-0.0571 0.0516 +/-0.0575 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.00601 +/-0.0230 0.0403 +/-0.0230 0.0425 pCi/g KP1 08/05/22 1833 2295040 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 0.628 +/-5.90 10.1 +/-5.90 19.5 pCi/g TXJ1 08/04/22 2146 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 07/12/22 0928 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295040 48.6 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 89 (25%-125%)

Page 23 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12201E-FSGS-207-SS Project: ENRG08001 Sample ID: 587450011 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 24 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12201E-FSGS-208-SS Project: ENRG08001 Sample ID: 587450012 Client ID: ENRG080 Matrix: Soil Collect Date: 29-JUN-22 Receive Date: 11-JUL-22 Collector: Client Moisture: 2.2%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.223 +/-0.134 0.297 +/-0.169 pCi/g MJH1 07/28/22 1737 2295333 1 Bismuth-211 U 0.362 +/-0.172 0.406 +/-0.240 pCi/g Bismuth-212 U 0.0155 +/-0.299 0.615 +/-0.299 pCi/g Bismuth-214 0.158 +/-0.102 0.0890 +/-0.102 pCi/g Cesium-134 U 0.0103 +/-0.0289 0.0612 +/-0.0293 0.173 pCi/g Cesium-137 U 0.00964 +/-0.0234 0.0510 +/-0.0238 0.363 pCi/g Cobalt-60 U 0.0211 +/-0.0265 0.0664 +/-0.0282 0.109 pCi/g Europium-152 U -0.00180 +/-0.0599 0.118 +/-0.0599 0.869 pCi/g Europium-154 U -0.00940 +/-0.0643 0.137 +/-0.0644 0.799 pCi/g Lead-212 UI 0.000 +/-0.0788 0.138 +/-0.148 pCi/g Lead-214 0.184 +/-0.147 0.0838 +/-0.148 pCi/g Potassium-40 10.9 +/-1.32 0.500 +/-1.70 pCi/g Thallium-208 U 0.0274 +/-0.0541 0.0442 +/-0.0542 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.0248 +/-0.0201 0.0408 +/-0.0201 0.0425 pCi/g KP1 08/09/22 1813 2295041 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U -0.198 +/-6.40 11.0 +/-6.40 19.5 pCi/g TXJ1 08/04/22 2217 2295673 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 07/12/22 0928 2295002 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295041 50.9 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295673 82.4 (25%-125%)

Page 25 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12201E-FSGS-208-SS Project: ENRG08001 Sample ID: 587450012 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 26 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12205A-FSGS-311-SS Project: ENRG08001 Sample ID: 587450013 Client ID: ENRG080 Matrix: Soil Collect Date: 23-JUN-22 Receive Date: 06-JUL-22 Collector: Client Moisture: 4.32%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.363 +/-0.148 0.131 +/-0.152 pCi/g MJH1 07/28/22 1740 2295333 1 Bismuth-211 UI 0.000 +/-0.872 0.201 +/-0.873 pCi/g Bismuth-212 U 0.263 +/-0.642 0.692 +/-0.643 pCi/g Bismuth-214 UI 0.000 +/-0.147 0.0902 +/-0.148 pCi/g Cesium-134 U 0.0410 +/-0.0301 0.0588 +/-0.0355 0.173 pCi/g Cesium-137 U 0.00897 +/-0.0482 0.0509 +/-0.0482 0.363 pCi/g Cobalt-60 U -0.00453 +/-0.0208 0.0417 +/-0.0209 0.109 pCi/g Europium-152 U 0.0349 +/-0.0539 0.110 +/-0.0562 0.869 pCi/g Europium-154 U 0.0184 +/-0.0707 0.153 +/-0.0712 0.799 pCi/g Lead-212 0.191 +/-0.102 0.0643 +/-0.103 pCi/g Lead-214 0.272 +/-0.107 0.148 +/-0.109 pCi/g Potassium-40 10.6 +/-1.20 0.470 +/-1.54 pCi/g Thallium-208 U 0.0294 +/-0.0305 0.0660 +/-0.0333 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U 0.0182 +/-0.0243 0.0416 +/-0.0246 0.0425 pCi/g KP1 08/09/22 1813 2295041 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U -0.117 +/-6.23 10.8 +/-6.23 19.5 pCi/g TXJ1 08/04/22 1825 2295678 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 07/06/22 1150 2295010 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295041 43.9 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295678 75.7 (25%-125%)

Page 27 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12205A-FSGS-311-SS Project: ENRG08001 Sample ID: 587450013 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 28 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12205A-FSGS-312-SS Project: ENRG08001 Sample ID: 587450014 Client ID: ENRG080 Matrix: Soil Collect Date: 23-JUN-22 Receive Date: 06-JUL-22 Collector: Client Moisture: .282%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.190 +/-0.149 0.272 +/-0.173 pCi/g MJH1 07/28/22 1740 2295333 1 Bismuth-211 U 0.101 +/-0.462 0.143 +/-0.468 pCi/g Bismuth-212 U 0.524 +/-0.504 0.536 +/-0.507 pCi/g Bismuth-214 0.221 +/-0.0888 0.0747 +/-0.0910 pCi/g Cesium-134 U 0.0248 +/-0.0259 0.0602 +/-0.0283 0.173 pCi/g Cesium-137 U -0.0139 +/-0.0228 0.0420 +/-0.0237 0.363 pCi/g Cobalt-60 U -0.0157 +/-0.0222 0.0399 +/-0.0233 0.109 pCi/g Europium-152 U 0.0124 +/-0.0536 0.0994 +/-0.0539 0.869 pCi/g Europium-154 U 0.0404 +/-0.0776 0.179 +/-0.0798 0.799 pCi/g Lead-212 0.198 +/-0.0796 0.0591 +/-0.0812 pCi/g Lead-214 0.307 +/-0.0880 0.145 +/-0.0914 pCi/g Potassium-40 11.2 +/-1.25 0.267 +/-1.59 pCi/g Thallium-208 U 0.0334 +/-0.0431 0.0397 +/-0.0432 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.00904 +/-0.0164 0.0323 +/-0.0164 0.0425 pCi/g KP1 08/09/22 1813 2295041 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 2.23 +/-6.64 11.4 +/-6.65 19.5 pCi/g TXJ1 08/04/22 1857 2295678 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 07/06/22 1150 2295010 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295041 97.1 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295678 68.6 (25%-125%)

Page 29 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12205A-FSGS-312-SS Project: ENRG08001 Sample ID: 587450014 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 30 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FSGS-048-SS Project: ENRG08001 Sample ID: 587450015 Client ID: ENRG080 Matrix: Soil Collect Date: 21-MAR-22 Receive Date: 07-APR-22 Collector: Client Moisture: 7.17%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.333 +/-0.152 0.149 +/-0.155 pCi/g RXF2 07/29/22 0913 2295332 1 Bismuth-211 UI 0.000 +/-0.233 0.308 +/-0.410 pCi/g Bismuth-212 U 0.307 +/-0.299 0.607 +/-0.330 pCi/g Bismuth-214 0.267 +/-0.0955 0.0582 +/-0.0982 pCi/g Cesium-134 U 0.0204 +/-0.0235 0.0512 +/-0.0253 0.173 pCi/g Cesium-137 0.112 +/-0.0422 0.0388 +/-0.0432 0.363 pCi/g Cobalt-60 U 0.0518 +/-0.0323 0.0721 +/-0.0402 0.109 pCi/g Europium-152 U 0.0242 +/-0.0453 0.0942 +/-0.0467 0.869 pCi/g Europium-154 U -0.0384 +/-0.0701 0.121 +/-0.0722 0.799 pCi/g Lead-212 0.302 +/-0.0556 0.0447 +/-0.0614 pCi/g Lead-214 0.267 +/-0.0844 0.0650 +/-0.0873 pCi/g Potassium-40 9.18 +/-0.968 0.440 +/-1.31 pCi/g Thallium-208 0.0685 +/-0.0526 0.0332 +/-0.0529 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U 0.0133 +/-0.0187 0.0320 +/-0.0189 0.0425 pCi/g KP1 08/09/22 1813 2295041 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 1.69 +/-6.65 11.4 +/-6.66 19.5 pCi/g TXJ1 08/04/22 1928 2295678 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 04/08/22 0925 2295010 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295041 69.4 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295678 74 (25%-125%)

Page 31 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FSGS-048-SS Project: ENRG08001 Sample ID: 587450015 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 32 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FSGS-061-SS Project: ENRG08001 Sample ID: 587450016 Client ID: ENRG080 Matrix: Soil Collect Date: 22-MAR-22 Receive Date: 07-APR-22 Collector: Client Moisture: 9.65%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.318 +/-0.231 0.187 +/-0.233 pCi/g RXF2 07/29/22 0914 2295332 1 Bismuth-211 UI 0.000 +/-0.375 0.495 +/-0.672 pCi/g Bismuth-212 U 0.721 +/-0.746 0.758 +/-0.749 pCi/g Bismuth-214 0.429 +/-0.141 0.0995 +/-0.146 pCi/g Cesium-134 U 0.0109 +/-0.0381 0.0738 +/-0.0385 0.173 pCi/g Cesium-137 0.417 +/-0.0860 0.0514 +/-0.0926 0.363 pCi/g Cobalt-60 U -0.0226 +/-0.0307 0.0542 +/-0.0324 0.109 pCi/g Europium-152 U 0.0419 +/-0.0680 0.131 +/-0.0706 0.869 pCi/g Europium-154 U 0.0141 +/-0.0941 0.189 +/-0.0943 0.799 pCi/g Lead-212 0.417 +/-0.0883 0.0699 +/-0.0939 pCi/g Lead-214 0.441 +/-0.136 0.100 +/-0.141 pCi/g Potassium-40 11.5 +/-1.25 0.615 +/-1.63 pCi/g Thallium-208 0.141 +/-0.0645 0.0477 +/-0.0658 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U 0.0166 +/-0.0195 0.0330 +/-0.0198 0.0425 pCi/g KP1 08/09/22 1813 2295041 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U -0.818 +/-6.80 11.8 +/-6.80 19.5 pCi/g TXJ1 08/04/22 2000 2295678 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 04/08/22 0925 2295010 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295041 74 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295678 71.7 (25%-125%)

Page 33 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FSGS-061-SS Project: ENRG08001 Sample ID: 587450016 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 34 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FIGS-029-SS Project: ENRG08001 Sample ID: 587450017 Client ID: ENRG080 Matrix: Soil Collect Date: 22-MAR-22 Receive Date: 07-APR-22 Collector: Client Moisture: 11.5%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.489 +/-0.147 0.114 +/-0.155 pCi/g RXF2 07/29/22 1016 2295332 1 Bismuth-211 UI 0.000 +/-0.335 0.366 +/-0.729 pCi/g Bismuth-212 UI 0.000 +/-0.369 0.378 +/-0.381 pCi/g Bismuth-214 0.505 +/-0.0906 0.0623 +/-0.102 pCi/g Cesium-134 UI 0.000 +/-0.0345 0.0428 +/-0.0452 0.173 pCi/g Cesium-137 2.59 +/-0.0984 0.0307 +/-0.261 0.363 pCi/g Cobalt-60 U 0.0122 +/-0.0203 0.0369 +/-0.0211 0.109 pCi/g Europium-152 U -0.0560 +/-0.0527 0.0895 +/-0.0586 0.869 pCi/g Europium-154 U 0.0374 +/-0.0704 0.118 +/-0.0725 0.799 pCi/g Lead-212 0.502 +/-0.0830 0.0583 +/-0.0922 pCi/g Lead-214 0.513 +/-0.122 0.0713 +/-0.129 pCi/g Potassium-40 13.9 +/-0.819 0.261 +/-1.49 pCi/g Thallium-208 0.143 +/-0.0352 0.0312 +/-0.0376 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U 0.00312 +/-0.0177 0.0320 +/-0.0177 0.0425 pCi/g KP1 08/09/22 1813 2295041 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 0.236 +/-6.47 11.2 +/-6.47 19.5 pCi/g TXJ1 08/04/22 2032 2295678 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 04/08/22 0925 2295010 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295041 90.2 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295678 74 (25%-125%)

Page 35 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FIGS-029-SS Project: ENRG08001 Sample ID: 587450017 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 36 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FIGS-031-SS Project: ENRG08001 Sample ID: 587450018 Client ID: ENRG080 Matrix: Soil Collect Date: 22-MAR-22 Receive Date: 07-APR-22 Collector: Client Moisture: 6.7%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 UI 0.000 +/-0.158 0.308 +/-0.215 pCi/g RXF2 07/29/22 1208 2295332 1 Bismuth-211 UI 0.000 +/-0.401 0.483 +/-0.567 pCi/g Bismuth-212 U 0.410 +/-0.395 0.876 +/-0.438 pCi/g Bismuth-214 0.228 +/-0.118 0.0907 +/-0.119 pCi/g Cesium-134 U 0.0257 +/-0.0304 0.0675 +/-0.0326 0.173 pCi/g Cesium-137 2.85 +/-0.170 0.0484 +/-0.293 0.363 pCi/g Cobalt-60 U 0.00786 +/-0.0284 0.0633 +/-0.0286 0.109 pCi/g Europium-152 U 0.0133 +/-0.0756 0.152 +/-0.0759 0.869 pCi/g Europium-154 U 0.0489 +/-0.0937 0.182 +/-0.0964 0.799 pCi/g Lead-212 0.331 +/-0.0878 0.0687 +/-0.0919 pCi/g Lead-214 0.317 +/-0.146 0.110 +/-0.148 pCi/g Potassium-40 9.64 +/-1.19 0.479 +/-1.51 pCi/g Thallium-208 0.0986 +/-0.0616 0.0442 +/-0.0621 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U 0.0178 +/-0.0244 0.0417 +/-0.0246 0.0425 pCi/g KP1 08/09/22 1813 2295041 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 6.06 +/-6.36 10.7 +/-6.45 19.5 pCi/g TXJ1 08/04/22 2104 2295678 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 04/08/22 0931 2295010 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295041 43.9 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295678 80.2 (25%-125%)

Page 37 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FIGS-031-SS Project: ENRG08001 Sample ID: 587450018 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 38 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-QIGS-031-SS Project: ENRG08001 Sample ID: 587450019 Client ID: ENRG080 Matrix: Soil Collect Date: 22-MAR-22 Receive Date: 07-APR-22 Collector: Client Moisture: 6.69%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.143 +/-0.157 0.277 +/-0.170 pCi/g RXF2 07/29/22 1250 2295332 1 Bismuth-211 UI 0.000 +/-0.646 0.285 +/-0.654 pCi/g Bismuth-212 U 0.301 +/-0.309 0.611 +/-0.310 pCi/g Bismuth-214 0.222 +/-0.172 0.0909 +/-0.173 pCi/g Cesium-134 U 0.00722 +/-0.0261 0.0555 +/-0.0263 0.173 pCi/g Cesium-137 3.12 +/-0.180 0.0440 +/-0.334 0.363 pCi/g Cobalt-60 U 0.0126 +/-0.0251 0.0592 +/-0.0257 0.109 pCi/g Europium-152 U -0.0503 +/-0.0771 0.131 +/-0.0805 0.869 pCi/g Europium-154 U -0.0253 +/-0.0775 0.154 +/-0.0784 0.799 pCi/g Lead-212 0.265 +/-0.114 0.0838 +/-0.116 pCi/g Lead-214 0.453 +/-0.136 0.182 +/-0.141 pCi/g Potassium-40 10.1 +/-1.27 0.556 +/-1.55 pCi/g Thallium-208 0.106 +/-0.0656 0.0477 +/-0.0663 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U 0.0289 +/-0.0203 0.0322 +/-0.0210 0.0425 pCi/g KP1 08/09/22 1813 2295041 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 1.67 +/-6.69 11.5 +/-6.70 19.5 pCi/g TXJ1 08/04/22 2135 2295678 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 04/08/22 0931 2295010 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295041 116 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295678 66.4 (25%-125%)

Page 39 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-QIGS-031-SS Project: ENRG08001 Sample ID: 587450019 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 40 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FIGS-032-SS Project: ENRG08001 Sample ID: 587450020 Client ID: ENRG080 Matrix: Soil Collect Date: 22-MAR-22 Receive Date: 07-APR-22 Collector: Client Moisture: 8.27%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 UI 0.000 +/-0.152 0.163 +/-0.156 pCi/g RXF2 07/29/22 1250 2295332 1 Bismuth-211 UI 0.000 +/-0.303 0.426 +/-0.412 pCi/g Bismuth-212 0.968 +/-0.342 0.545 +/-0.355 pCi/g Bismuth-214 0.237 +/-0.107 0.0953 +/-0.110 pCi/g Cesium-134 U -0.00236 +/-0.0262 0.0510 +/-0.0263 0.173 pCi/g Cesium-137 1.33 +/-0.107 0.0511 +/-0.164 0.363 pCi/g Cobalt-60 U 0.00536 +/-0.0254 0.0528 +/-0.0255 0.109 pCi/g Europium-152 U -0.0191 +/-0.0687 0.124 +/-0.0693 0.869 pCi/g Europium-154 U -0.0595 +/-0.0755 0.123 +/-0.0803 0.799 pCi/g Lead-212 0.284 +/-0.0995 0.0798 +/-0.102 pCi/g Lead-214 0.221 +/-0.110 0.0963 +/-0.111 pCi/g Potassium-40 11.7 +/-1.07 0.462 +/-1.50 pCi/g Thallium-208 0.0930 +/-0.0609 0.0530 +/-0.0615 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U -0.00182 +/-0.0180 0.0334 +/-0.0180 0.0425 pCi/g KP1 08/09/22 1814 2295041 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 0.792 +/-6.54 11.3 +/-6.55 19.5 pCi/g TXJ1 08/04/22 2207 2295678 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 04/08/22 0931 2295010 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295041 76.3 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295678 76.2 (25%-125%)

Page 41 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FIGS-032-SS Project: ENRG08001 Sample ID: 587450020 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 42 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FIGS-033-SS Project: ENRG08001 Sample ID: 587450021 Client ID: ENRG080 Matrix: Soil Collect Date: 22-MAR-22 Receive Date: 07-APR-22 Collector: Client Moisture: 6.74%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.266 +/-0.180 0.293 +/-0.217 pCi/g RXF2 07/29/22 1251 2295332 1 Bismuth-211 UI 0.000 +/-0.604 0.273 +/-0.609 pCi/g Bismuth-212 U 0.541 +/-0.582 0.636 +/-0.584 pCi/g Bismuth-214 UI 0.000 +/-0.0974 0.177 +/-0.161 pCi/g Cesium-134 U 0.0126 +/-0.0301 0.0631 +/-0.0306 0.173 pCi/g Cesium-137 0.653 +/-0.0907 0.0446 +/-0.107 0.363 pCi/g Cobalt-60 U -0.00557 +/-0.0226 0.0460 +/-0.0228 0.109 pCi/g Europium-152 U 0.00884 +/-0.0597 0.125 +/-0.0598 0.869 pCi/g Europium-154 U 0.0329 +/-0.0914 0.195 +/-0.0926 0.799 pCi/g Lead-212 0.288 +/-0.0995 0.0620 +/-0.102 pCi/g Lead-214 0.362 +/-0.135 0.183 +/-0.138 pCi/g Potassium-40 9.44 +/-1.23 0.470 +/-1.51 pCi/g Thallium-208 0.0688 +/-0.0486 0.0461 +/-0.0490 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, Solid "Dry Weight Corrected" Strontium-90 U 0.00511 +/-0.0185 0.0331 +/-0.0185 0.0425 pCi/g KP1 08/09/22 1814 2295041 2 Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid "Dry Weight Corrected" Nickel-63 U 0.490 +/-5.36 9.27 +/-5.36 19.5 pCi/g TXJ1 08/04/22 2239 2295678 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 CM2 04/08/22 0931 2295010 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R 2 EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 3 DOE RESL Ni-1, Modified Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Strontium Carrier GFPC, Sr90, Solid "Dry Weight Corrected" 2295041 85.5 (25%-125%)

Nickel Carrier Liquid Scint Ni63, Solid "Dry Weight Corrected" 2295678 78.4 (25%-125%)

Page 43 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: August 10, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-12112A-FIGS-033-SS Project: ENRG08001 Sample ID: 587450021 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 44 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: August 10, 2022 Client : Zion Solutions Page 1 of 8 100 Shiloh Blvd.

Zion, Illinois

Contact:

Mr. Gerry Wood Workorder: 587450 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2295332 QC1205149656 587450001 DUP Actinium-228 U 0.238 0.393 pCi/g 2.34 (0% - 100%) RXF2 07/29/22 12:52 Uncert: +/-0.192 +/-0.175 TPU: +/-0.221 +/-0.179 Bismuth-211 U 0.285 U 0.198 pCi/g 0 N/A Uncert: +/-0.933 +/-0.669 TPU: +/-0.937 +/-0.673 Bismuth-212 U 0.268 U 0.305 pCi/g 0 N/A Uncert: +/-0.635 +/-0.366 TPU: +/-0.647 +/-0.392 Bismuth-214 UI 0.000 UI 0.000 pCi/g 0 N/A Uncert: +/-0.165 +/-0.111 TPU: +/-0.229 +/-0.200 Cesium-134 U 0.00983 U 0.0115 pCi/g 0 N/A Uncert: +/-0.0363 +/-0.0274 TPU: +/-0.0366 +/-0.0279 Cesium-137 0.0931 0.124 pCi/g 28.5 (0% - 100%)

Uncert: +/-0.0758 +/-0.0515 TPU: +/-0.0762 +/-0.0525 Cobalt-60 U 0.0144 U 0.0111 pCi/g 0 N/A Uncert: +/-0.0395 +/-0.0266 TPU: +/-0.0400 +/-0.0271 Europium-152 U 0.0370 U 0.0312 pCi/g 0 N/A Uncert: +/-0.0874 +/-0.0555 TPU: +/-0.0890 +/-0.0574 Europium-154 U 0.0266 U 0.0558 pCi/g 0 N/A Uncert: +/-0.103 +/-0.0684 TPU: +/-0.104 +/-0.0730 Lead-212 0.375 0.309 pCi/g 19.2 (0% - 100%)

Uncert: +/-0.0992 +/-0.0791 TPU: +/-0.103 +/-0.0832 Lead-214 0.361 0.293 pCi/g 21.1 (0% - 100%)

Uncert: +/-0.195 +/-0.0955 TPU: +/-0.198 +/-0.0986 Potassium-40 8.11 8.52 pCi/g 4.92 (0%-20%)

Uncert: +/-1.28 +/-1.12 TPU: +/-1.48 +/-1.38 Thallium-208 0.118 0.0550 pCi/g 72.9 (0% - 100%)

Uncert: +/-0.0588 +/-0.0425 TPU: +/-0.0598 +/-0.0428 QC1205149657 LCS Americium-241 485 525 pCi/g 108 (75%-125%) RXF2 07/29/22 12:52 Page 45 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 587450 Page 2 of 8 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2295332 Uncert: +/-5.50 TPU: +/-40.4 Actinium-228 U -0.586 pCi/g Uncert: +/-2.82 TPU: +/-2.83 Bismuth-211 U -1.39 pCi/g Uncert: +/-2.77 TPU: +/-2.84 Bismuth-212 U -5.01 pCi/g Uncert: +/-7.08 TPU: +/-7.45 Bismuth-214 U 0.845 pCi/g Uncert: +/-1.51 TPU: +/-1.56 Cesium-134 U -0.569 pCi/g Uncert: +/-0.568 TPU: +/-0.625 Cesium-137 157 164 pCi/g 105 (75%-125%)

Uncert: +/-3.65 TPU: +/-16.3 Cobalt-60 74.7 73.2 pCi/g 98 (75%-125%)

Uncert: +/-3.00 TPU: +/-6.47 Europium-152 U 0.497 pCi/g Uncert: +/-1.30 TPU: +/-1.32 Europium-154 U -0.385 pCi/g Uncert: +/-0.889 TPU: +/-0.907 Lead-212 U -0.530 pCi/g Uncert: +/-0.706 TPU: +/-0.746 Lead-214 U 1.05 pCi/g Uncert: +/-0.997 TPU: +/-1.11 Potassium-40 U -0.744 pCi/g Uncert: +/-2.57 TPU: +/-2.59 Thallium-208 U -0.568 pCi/g Uncert: +/-0.572 TPU: +/-0.629 QC1205149655 MB Actinium-228 U -0.0212 pCi/g RXF2 07/29/2212:51 Uncert: +/-0.0665 TPU: +/-0.0672 Bismuth-211 U -0.0972 pCi/g Page 46 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 587450 Page 3 of 8 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2295332 Uncert: +/-0.105 TPU: +/-0.114 Bismuth-212 U -0.00458 pCi/g Uncert: +/-0.172 TPU: +/-0.172 Bismuth-214 U 0.0382 pCi/g Uncert: +/-0.0773 TPU: +/-0.0793 Cesium-134 U 0.00687 pCi/g Uncert: +/-0.0204 TPU: +/-0.0206 Cesium-137 U -0.0142 pCi/g Uncert: +/-0.0151 TPU: +/-0.0165 Cobalt-60 U 0.00749 pCi/g Uncert: +/-0.0124 TPU: +/-0.0128 Europium-152 U -0.0104 pCi/g Uncert: +/-0.0363 TPU: +/-0.0366 Europium-154 U 0.0105 pCi/g Uncert: +/-0.0183 TPU: +/-0.0190 Lead-212 U -0.0137 pCi/g Uncert: +/-0.0345 TPU: +/-0.0351 Lead-214 U -0.0465 pCi/g Uncert: +/-0.0394 TPU: +/-0.0448 Potassium-40 U 0.0106 pCi/g Uncert: +/-0.299 TPU: +/-0.299 Thallium-208 U -0.0178 pCi/g Uncert: +/-0.0187 TPU: +/-0.0204 Batch 2295333 QC1205149659 587450003 DUP Actinium-228 0.168 0.178 pCi/g 5.68 (0% - 100%) MJH1 07/28/2221:05 Uncert: +/-0.123 +/-0.148 TPU: +/-0.124 +/-0.149 Bismuth-211 UI 0.000 U 0.120 pCi/g 0 N/A Uncert: +/-0.249 +/-0.0250 TPU: +/-0.254 +/-0.0268 Bismuth-212 U -0.175 U -0.199 pCi/g 0 N/A Uncert: +/-0.320 +/-0.291 TPU: +/-0.330 +/-0.305 Page 47 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 587450 Page 4 of 8 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2295333 Bismuth-214 0.210 U 0.0875 pCi/g 36.9 (0% - 100%)

Uncert: +/-0.0894 +/-0.130 TPU: +/-0.0914 +/-0.136 Cesium-134 U 0.0421 U 0.00150 pCi/g 0 N/A Uncert: +/-0.0461 +/-0.0185 TPU: +/-0.0500 +/-0.0185 Cesium-137 U 0.0118 0.0260 pCi/g 42.3 (0% - 100%)

Uncert: +/-0.0392 +/-0.0227 TPU: +/-0.0392 +/-0.0229 Cobalt-60 U -0.00480 U 0.00821 pCi/g 0 N/A Uncert: +/-0.0239 +/-0.0177 TPU: +/-0.0240 +/-0.0181 Europium-152 U 0.000947 U 0.0171 pCi/g 0 N/A Uncert: +/-0.0485 +/-0.0541 TPU: +/-0.0485 +/-0.0547 Europium-154 U 0.00908 U 0.0152 pCi/g 0 N/A Uncert: +/-0.0586 +/-0.0577 TPU: +/-0.0588 +/-0.0581 Lead-212 0.287 0.134 pCi/g 72.7 * (0%-20%)

Uncert: +/-0.0691 +/-0.0690 TPU: +/-0.0731 +/-0.0699 Lead-214 0.215 0.289 pCi/g 29.5 * (0%-20%)

Uncert: +/-0.0902 +/-0.0755 TPU: +/-0.134 +/-0.0790 Potassium-40 4.54 5.30 pCi/g 15.5 (0%-20%)

Uncert: +/-0.854 +/-0.925 TPU: +/-0.947 +/-1.04 Thallium-208 U 0.0192 0.0438 pCi/g 16.8 (0% - 100%)

Uncert: +/-0.0412 +/-0.0357 TPU: +/-0.0412 +/-0.0359 QC1205149660 LCS Americium-241 485 521 pCi/g 108 (75%-125%) MJH1 07/28/2221:02 Uncert: +/-10.7 TPU: +/-60.1 Actinium-228 U -2.05 pCi/g Uncert: +/-2.10 TPU: +/-2.31 Bismuth-211 U 0.128 pCi/g Uncert: +/-2.76 TPU: +/-2.77 Bismuth-212 U 7.86 pCi/g Uncert: +/-5.67 TPU: +/-6.73 Bismuth-214 U 0.345 pCi/g Uncert: +/-0.872 TPU: +/-0.886 Page 48 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 587450 Page 5 of 8 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2295333 Cesium-134 U 0.0206 pCi/g Uncert: +/-0.520 TPU: +/-0.520 Cesium-137 157 154 pCi/g 98.3 (75%-125%)

Uncert: +/-3.09 TPU: +/-13.6 Cobalt-60 75.1 74.5 pCi/g 99.3 (75%-125%)

Uncert: +/-2.68 TPU: +/-7.81 Europium-152 U 0.119 pCi/g Uncert: +/-1.47 TPU: +/-1.47 Europium-154 U 0.290 pCi/g Uncert: +/-0.871 TPU: +/-0.881 Lead-212 U 0.499 pCi/g Uncert: +/-0.683 TPU: +/-0.721 Lead-214 U -0.465 pCi/g Uncert: +/-1.02 TPU: +/-1.04 Potassium-40 U -0.968 pCi/g Uncert: +/-1.63 TPU: +/-1.69 Thallium-208 U 0.131 pCi/g Uncert: +/-0.431 TPU: +/-0.435 QC1205149658 MB Actinium-228 U 0.0117 pCi/g MJH1 07/28/2217:42 Uncert: +/-0.0872 TPU: +/-0.0874 Bismuth-211 U 0.0210 pCi/g Uncert: +/-0.232 TPU: +/-0.232 Bismuth-212 U 0.0618 pCi/g Uncert: +/-0.242 TPU: +/-0.244 Bismuth-214 U -0.00876 pCi/g Uncert: +/-0.0405 TPU: +/-0.0407 Cesium-134 U -0.0193 pCi/g Uncert: +/-0.0178 TPU: +/-0.0199 Cesium-137 U 0.0114 pCi/g Uncert: +/-0.0183 TPU: +/-0.0191 Page 49 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 587450 Page 6 of 8 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2295333 Cobalt-60 U 0.00413 pCi/g Uncert: +/-0.0148 TPU: +/-0.0150 Europium-152 U 0.0258 pCi/g Uncert: +/-0.0483 TPU: +/-0.0498 Europium-154 U 0.0189 pCi/g Uncert: +/-0.0261 TPU: +/-0.0275 Lead-212 U 0.0163 pCi/g Uncert: +/-0.0319 TPU: +/-0.0328 Lead-214 U -0.0253 pCi/g Uncert: +/-0.0456 TPU: +/-0.0470 Potassium-40 U 0.0234 pCi/g Uncert: +/-0.279 TPU: +/-0.279 Thallium-208 U -0.00342 pCi/g Uncert: +/-0.0216 TPU: +/-0.0216 Rad Gas Flow Batch 2295040 QC1205149167 587450001 DUP Strontium-90 U -0.00507 0.0774 pCi/g 228* (0% - 100%) KP1 08/09/22 19:01 Uncert: +/-0.0115 +/-0.0263 TPU: +/-0.0115 +/-0.0298 QC1205149168 LCS Strontium-90 1.67 1.81 pCi/g 108 (75%-125%) KP1 08/03/22 18:25 Uncert: +/-0.113 TPU: +/-0.342 QC1205149166 MB Strontium-90 U -0.00293 pCi/g KP1 08/03/22 18:25 Uncert: +/-0.0115 TPU: +/-0.0115 Batch 2295041 QC1205149170 587450012 DUP Strontium-90 U -0.0248 U -0.00579 pCi/g 0 N/A KP1 08/09/22 18:13 Uncert: +/-0.0201 +/-0.0222 TPU: +/-0.0201 +/-0.0222 QC1205149171 LCS Strontium-90 1.67 1.66 pCi/g 99.5 (75%-125%) KP1 08/09/22 18:13 Uncert: +/-0.0902 TPU: +/-0.310 QC1205149169 MB Page 50 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 587450 Page 7 of 8 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gas Flow Batch 2295041 Strontium-90 U 0.00486 pCi/g KP1 08/09/22 18:13 Uncert: +/-0.0182 TPU: +/-0.0182 Rad Liquid Scintillation Batch 2295673 QC1205150420 587450003 DUP Nickel-63 U 0.555 U 4.38 pCi/g 0 N/A TXJ1 08/04/22 23:19 Uncert: +/-6.01 +/-6.85 TPU: +/-6.01 +/-6.90 QC1205150421 LCS Nickel-63 427 447 pCi/g 105 (75%-125%) TXJ1 08/04/22 23:49 Uncert: +/-14.2 TPU: +/-84.1 QC1205150419 MB Nickel-63 U -0.145 pCi/g TXJ1 08/04/22 22:48 Uncert: +/-6.37 TPU: +/-6.37 Batch 2295678 QC1205150427 587450013 DUP Nickel-63 U -0.117 U -2.66 pCi/g 0 N/A TXJ1 08/04/22 23:42 Uncert: +/-6.23 +/-5.41 TPU: +/-6.23 +/-5.41 QC1205150428 LCS Nickel-63 402 368 pCi/g 91.7 (75%-125%) TXJ1 08/05/22 00:14 Uncert: +/-12.5 TPU: +/-69.3 QC1205150426 MB Nickel-63 U 1.39 pCi/g TXJ1 08/04/22 23:10 Uncert: +/-5.20 TPU: +/-5.21 Notes:

TPU and Counting Uncertainty are calculated at the 95% confidence level (1.96-sigma).

The Qualifiers in this report are defined as follows:

    • Analyte is a Tracer compound

< Result is less than value reported

> Result is greater than value reported BD Results are either below the MDC or tracer recovery is low FA Failed analysis.

H Analytical holding time was exceeded J See case narrative for an explanation J Value is estimated K Analyte present. Reported value may be biased high. Actual value is expected to be lower.

L Analyte present. Reported value may be biased low. Actual value is expected to be higher.

Page 51 of 100 SDG: 587450

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 587450 Page 8 of 8 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time M M if above MDC and less than LLD M REMP Result > MDC/CL and < RDL N/A RPD or %Recovery limits do not apply.

N1 See case narrative ND Analyte concentration is not detected above the detection limit NJ Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Q One or more quality control criteria have not been met. Refer to the applicable narrative or DER.

R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.

UI Gamma Spectroscopy--Uncertain identification UJ Gamma Spectroscopy--Uncertain identification UL Not considered detected. The associated number is the reported concentration, which may be inaccurate due to a low bias.

X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y Other specific qualifiers were required to properly define the results. Consult case narrative.

^ RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more or %RPD not applicable.

    • Indicates analyte is a surrogate/tracer compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

Page 52 of 100 SDG: 587450

Page 53 of 100 SDG: 587450 Page 54 of 100 SDG: 587450 Page 55 of 100 SDG: 587450 Page 56 of 100 SDG: 587450 Page 57 of 100 SDG: 587450 Page 58 of 100 SDG: 587450 Page 59 of 100 SDG: 587450 Page 60 of 100 SDG: 587450 Page 61 of 100 SDG: 587450 Page 62 of 100 SDG: 587450 Page 63 of 100 SDG: 587450 Page 64 of 100 SDG: 587450 Page 65 of 100 SDG: 587450 Page 66 of 100 SDG: 587450 Page 67 of 100 SDG: 587450 Page 68 of 100 SDG: 587450 Page 69 of 100 SDG: 587450 Page 70 of 100 SDG: 587450 Page 71 of 100 SDG: 587450 Page 72 of 100 SDG: 587450 Page 73 of 100 SDG: 587450 Page 74 of 100 SDG: 587450 Page 75 of 100 SDG: 587450 Page 76 of 100 SDG: 587450 Page 77 of 100 SDG: 587450 Page 78 of 100 SDG: 587450 Page 79 of 100 SDG: 587450 Page 80 of 100 SDG: 587450 Page 81 of 100 SDG: 587450 Page 82 of 100 SDG: 587450 Page 83 of 100 SDG: 587450 Page 84 of 100 SDG: 587450 Page 85 of 100 SDG: 587450 Page 86 of 100 SDG: 587450 Page 87 of 100 SDG: 587450 Page 88 of 100 SDG: 587450 Zachary Worsham From: Gerald Wood-ext <glwood-ext@energysolutions.com>

Sent: Tuesday, July 26, 2022 5:02 PM To: Zachary Worsham Cc: Team Worsham

Subject:

samples needing additional analysis

[EXTERNAL EMAIL] DO NOT CLICK links or attachments unless you recognize the sender and know the content is safe.

Hello Zac, Please analyze the following samples on a 10 day TAT, if any of the requested analysis cannot be executed on a 10 day TAT please let me know.

The Sr90 and Ni63 MDAs are listed as well as the other nuclides we more typically request.

The following samples in GEL custody will need 5 ROC Soil analysis:

L110201CFSGS211SS L110201CFSGS212SS L110201DFSGS205SS L110201DFSGS213SS L110202CFSGS204SS L110202CFSGS211SS L110202DFSGS216SS L110202DFSGS215SS L112201DFSGS309SS L112201DFSGS315SS L112201EFSGS207SS L112201EFSGS208SS L112205AFSGS311SS L112205AFSGS312SS L112112AFSGS048SS L112112AFSGS061SS L112112AFIGS029SS L112112AFIGS031SS L112112AQIGS031SS L112112AFIGS032SS L112112AFIGS033SS 5 ROC (soil)

Nuclide MDA (pCi/gm)

K-40 --

Bi-211/212/214 --

Pb212/214 --

Ac-228 --

1 Page 89 of 100 SDG: 587450

Ti-208 --

Co-60 1.091E-01 Cs-134 1.733E-01 Cs-137 3.630E-01 Eu-152 8.700E-01 Eu-154 8.000E-01 Ni-63 1.953E+01 Sr-90 4.250E-02 B/R, Gerry W.

Gerald L. Wood ZSRP Site Closure Team Zion Nuclear Power Station glwoodext@energysolutions.com 518.683.8849 2

Page 90 of 100 SDG: 587450

List of current GEL Certifications as of 10 August 2022 State Certification Alabama 42200 Alaska 17018 Alaska Drinking Water SC00012 Arkansas 880651 CLIA 42D0904046 California 2940 Colorado SC00012 Connecticut PH0169 DoD ELAP/ ISO17025 A2LA 2567.01 Florida NELAP E87156 Foreign Soils Permit P3301500283, P3301500253 Georgia SC00012 Georgia SDWA 967 Hawaii SC00012 Idaho SC00012 Illinois NELAP 200029 Indiana CSC01 Kansas NELAP E10332 Kentucky SDWA 90129 Kentucky Wastewater 90129 Louisiana Drinking Water LA024 Louisiana NELAP 03046 (AI33904)

Maine 2019020 Maryland 270 Massachusetts MSC012 Massachusetts PFAS Approv Letter Michigan 9976 Mississippi SC00012 Nebraska NEOS2613 Nevada SC0001220225 New Hampshire NELAP 2054 New Jersey NELAP SC002 New Mexico SC00012 New York NELAP 11501 North Carolina 233 North Carolina SDWA 45709 North Dakota R158 Oklahoma 2019165 Pennsylvania NELAP 6800485 Puerto Rico SC00012 S. Carolina Radiochem 10120002 Sanitation Districts of L 9255651 South Carolina Chemistry 10120001 Tennessee TN 02934 Texas NELAP T1047042352220 Utah NELAP SC00012202136 Vermont VT87156 Virginia NELAP 460202 Washington C780 Page 91 of 100 SDG: 587450

Radiochemistry Technical Case Narrative Zion Solutions SDG #: 587450 Product: Dry Weight Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2295002 The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 587450001 L1-10201C-FSGS-211-SS 587450002 L1-10201C-FSGS-212-SS 587450003 L1-10201D-FSGS-205-SS 587450004 L1-10201D-FSGS-213-SS 587450005 L1-10202C-FSGS-204-SS 587450006 L1-10202C-FSGS-211-SS 587450007 L1-10202D-FSGS-216-SS 587450008 L1-10202D-FSGS-215-SS 587450009 L1-12201D-FSGS-309-SS 587450010 L1-12201D-FSGS-315-SS 587450011 L1-12201E-FSGS-207-SS 587450012 L1-12201E-FSGS-208-SS The samples in this SDG were analyzed on an "as received" basis.

Data Summary:

All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable, with the following exceptions.

Miscellaneous Information Additional Comments Data transferred from batches 2276388,2284255, 2284251, 2286088 and 2288317.

Product: Dry Weight Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2295010 The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 587450013 L1-12205A-FSGS-311-SS 587450014 L1-12205A-FSGS-312-SS Page 92 of 100 SDG: 587450

587450015 L1-12112A-FSGS-048-SS 587450016 L1-12112A-FSGS-061-SS 587450017 L1-12112A-FIGS-029-SS 587450018 L1-12112A-FIGS-031-SS 587450019 L1-12112A-QIGS-031-SS 587450020 L1-12112A-FIGS-032-SS 587450021 L1-12112A-FIGS-033-SS The samples in this SDG were analyzed on an "as received" basis.

Data Summary:

All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable, with the following exceptions.

Miscellaneous Information Additional Comments Data transferred from 2286097,2251286 and 2251288.

Product: Gammaspec, Gamma, Solid (Requested List)

Analytical Method: DOE HASL 300, 4.5.2.3/Ga-01-R Analytical Procedure: GL-RAD-A-013 REV# 27 Analytical Batch: 2295332 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batches: 2295002 and 2295010 The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 587450001 L1-10201C-FSGS-211-SS 587450002 L1-10201C-FSGS-212-SS 587450015 L1-12112A-FSGS-048-SS 587450016 L1-12112A-FSGS-061-SS 587450017 L1-12112A-FIGS-029-SS 587450018 L1-12112A-FIGS-031-SS 587450019 L1-12112A-QIGS-031-SS 587450020 L1-12112A-FIGS-032-SS 587450021 L1-12112A-FIGS-033-SS 1205149655 Method Blank (MB) 1205149656 587450001(L1-10201C-FSGS-211-SS) Sample Duplicate (DUP) 1205149657 Laboratory Control Sample (LCS)

The samples in this SDG were analyzed on a "dry weight" basis.

Data Summary:

There are no exceptions, anomalies or deviations from the specified methods. All sample data provided in this Page 93 of 100 SDG: 587450

report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable.

Qualifier Information Qualifier Reason Analyte Sample Client Sample Results are considered a false UI positive due Bismuth-211 587450019 L1-12112A-QIGS-031-SS to high counting uncertainty.

Bismuth-211 587450021 L1-12112A-FIGS-033-SS Results are considered a false UI Actinium-228 587450020 L1-12112A-FIGS-032-SS positive due to high peak-width.

Bismuth-212 587450017 L1-12112A-FIGS-029-SS Cesium-137 587450002 L1-10201C-FSGS-212-SS Results are considered a false UI Actinium-228 587450018 L1-12112A-FIGS-031-SS positive due to low abundance.

Bismuth-211 587450002 L1-10201C-FSGS-212-SS Bismuth-211 587450015 L1-12112A-FSGS-048-SS Bismuth-211 587450016 L1-12112A-FSGS-061-SS Bismuth-211 587450017 L1-12112A-FIGS-029-SS Bismuth-211 587450018 L1-12112A-FIGS-031-SS Bismuth-211 587450020 L1-12112A-FIGS-032-SS Bismuth-214 587450001 L1-10201C-FSGS-211-SS Bismuth-214 587450021 L1-12112A-FIGS-033-SS Bismuth-214 1205149656 L1-10201C-FSGS-211-SS(587450001DUP)

Cesium-134 587450017 L1-12112A-FIGS-029-SS Page 94 of 100 SDG: 587450

Product: Gammaspec, Gamma, Solid (Requested List)

Analytical Method: DOE HASL 300, 4.5.2.3/Ga-01-R Analytical Procedure: GL-RAD-A-013 REV# 27 Analytical Batch: 2295333 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batches: 2295002 and 2295010 The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 587450003 L1-10201D-FSGS-205-SS 587450004 L1-10201D-FSGS-213-SS 587450005 L1-10202C-FSGS-204-SS 587450006 L1-10202C-FSGS-211-SS 587450007 L1-10202D-FSGS-216-SS 587450008 L1-10202D-FSGS-215-SS 587450009 L1-12201D-FSGS-309-SS 587450010 L1-12201D-FSGS-315-SS 587450011 L1-12201E-FSGS-207-SS 587450012 L1-12201E-FSGS-208-SS 587450013 L1-12205A-FSGS-311-SS 587450014 L1-12205A-FSGS-312-SS 1205149658 Method Blank (MB) 1205149659 587450003(L1-10201D-FSGS-205-SS) Sample Duplicate (DUP) 1205149660 Laboratory Control Sample (LCS)

The samples in this SDG were analyzed on a "dry weight" basis.

Data Summary:

All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable, with the following exceptions.

Quality Control (QC) Information Duplication Criteria between QC Sample and Duplicate Sample The Sample and the Duplicate, (See Below), did not meet the relative percent difference requirement; however, they do meet the relative error ratio requirement with the value listed below.

Sample Analyte Value 1205149659 (L1-10201D-FSGS-205-SSDUP) Lead-212 RPD 72.7* (0.00%-20.00%) RER 2.96 (0-3)

Lead-214 RPD 29.5* (0.00%-20.00%) RER 0.939 (0-3)

Qualifier Information Page 95 of 100 SDG: 587450

Qualifier Reason Analyte Sample Client Sample Results are considered a false UI positive due to high counting Bismuth-211 587450009 L1-12201D-FSGS-309-SS uncertainty.

Bismuth-211 587450013 L1-12205A-FSGS-311-SS Bismuth-212 587450005 L1-10202C-FSGS-204-SS Bismuth-214 587450013 L1-12205A-FSGS-311-SS Results are considered a false UI Bismuth-212 587450008 L1-10202D-FSGS-215-SS positive due to high peak-width.

Bismuth-212 587450009 L1-12201D-FSGS-309-SS Results are considered a false UI Bismuth-211 587450003 L1-10201D-FSGS-205-SS positive due to interference.

Results are considered a false UI Bismuth-211 587450005 L1-10202C-FSGS-204-SS positive due to low abundance.

Bismuth-211 587450006 L1-10202C-FSGS-211-SS Bismuth-211 587450007 L1-10202D-FSGS-216-SS Bismuth-211 587450008 L1-10202D-FSGS-215-SS Bismuth-211 587450010 L1-12201D-FSGS-315-SS Bismuth-214 587450011 L1-12201E-FSGS-207-SS Lead-212 587450012 L1-12201E-FSGS-208-SS Product: GFPC, Sr90, Solid Analytical Method: EPA 905.0 Modified/DOE RP501 Rev. 1 Modified Analytical Procedure: GL-RAD-A-004 REV# 22 Analytical Batch: 2295040 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2295002 The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 587450001 L1-10201C-FSGS-211-SS 587450002 L1-10201C-FSGS-212-SS 587450003 L1-10201D-FSGS-205-SS 587450004 L1-10201D-FSGS-213-SS 587450005 L1-10202C-FSGS-204-SS 587450006 L1-10202C-FSGS-211-SS 587450007 L1-10202D-FSGS-216-SS 587450008 L1-10202D-FSGS-215-SS 587450009 L1-12201D-FSGS-309-SS Page 96 of 100 SDG: 587450

587450010 L1-12201D-FSGS-315-SS 587450011 L1-12201E-FSGS-207-SS 1205149166 Method Blank (MB) 1205149167 587450001(L1-10201C-FSGS-211-SS) Sample Duplicate (DUP) 1205149168 Laboratory Control Sample (LCS)

The samples in this SDG were analyzed on a "dry weight" basis.

Data Summary:

All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable, with the following exceptions.

Preparation Information Homogenous Matrix Samples were non-homogenous matrix. Samples are sandy with various sized particles.

Quality Control (QC) Information Duplication Criteria between QC Sample and Duplicate Sample The Sample and Duplicate, (See Below), did not meet the duplication criteria due to the non-homogenous matrix of the samples.

Sample Analyte Value 1205149167 (L1-10201C-FSGS-211-SSDUP) Strontium-90 RPD 228* (0.0%-100.0%)

Technical Information Negative > 3 sigma TPU Sample results were more negative than the three sigma TPU. The background control charts were examined and the detectors were determined to be fully functional.

Sample Analyte Value 587450003 (L1-10201D-FSGS-205-SS) Strontium-90 Negative Result > 3 sigma value 587450005 (L1-10202C-FSGS-204-SS) Strontium-90 Negative Result > 3 sigma value Recounts Sample 587450011 (L1-12201E-FSGS-207-SS) was recounted due to results more negative than the three sigma TPU. The second count is reported. Sample 1205149167 (L1-10201C-FSGS-211-SSDUP) was recounted due to a suspected false positive. The recount is reported.

Product: GFPC, Sr90, Solid Analytical Method: EPA 905.0 Modified/DOE RP501 Rev. 1 Modified Analytical Procedure: GL-RAD-A-004 REV# 22 Analytical Batch: 2295041 Page 97 of 100 SDG: 587450

Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batches: 2295002 and 2295010 The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 587450012 L1-12201E-FSGS-208-SS 587450013 L1-12205A-FSGS-311-SS 587450014 L1-12205A-FSGS-312-SS 587450015 L1-12112A-FSGS-048-SS 587450016 L1-12112A-FSGS-061-SS 587450017 L1-12112A-FIGS-029-SS 587450018 L1-12112A-FIGS-031-SS 587450019 L1-12112A-QIGS-031-SS 587450020 L1-12112A-FIGS-032-SS 587450021 L1-12112A-FIGS-033-SS 1205149169 Method Blank (MB) 1205149170 587450012(L1-12201E-FSGS-208-SS) Sample Duplicate (DUP) 1205149171 Laboratory Control Sample (LCS)

The samples in this SDG were analyzed on a "dry weight" basis.

Data Summary:

All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable, with the following exceptions.

Preparation Information Procedure Variations Per Group Leader instructions, some variations were necessary to analyze difficult matrix. (Variations follow) 1205149170 (L1-12201E-FSGS-208-SSDUP), 587450012 (L1-12201E-FSGS-208-SS), 587450013 (L1-12205A-FSGS-311-SS) and 587450018 (L1-12112A-FIGS-031-SS). Additional clean up steps required.

Samples were out of calibration range after initial column work. 1205149170 (L1-12201E-FSGS-208-SSDUP),

587450012 (L1-12201E-FSGS-208-SS), 587450013 (L1-12205A-FSGS-311-SS) and 587450018 (L1-12112A-FIGS-031-SS).

Homogenous Matrix Samples were non-homogenous matrix. sandy Product: Liquid Scint Ni63, Solid Analytical Method: DOE RESL Ni-1, Modified Analytical Procedure: GL-RAD-A-022 REV# 19 Analytical Batch: 2295673 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2295002 Page 98 of 100 SDG: 587450

The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 587450001 L1-10201C-FSGS-211-SS 587450002 L1-10201C-FSGS-212-SS 587450003 L1-10201D-FSGS-205-SS 587450004 L1-10201D-FSGS-213-SS 587450005 L1-10202C-FSGS-204-SS 587450006 L1-10202C-FSGS-211-SS 587450007 L1-10202D-FSGS-216-SS 587450008 L1-10202D-FSGS-215-SS 587450009 L1-12201D-FSGS-309-SS 587450010 L1-12201D-FSGS-315-SS 587450011 L1-12201E-FSGS-207-SS 587450012 L1-12201E-FSGS-208-SS 1205150419 Method Blank (MB) 1205150420 587450003(L1-10201D-FSGS-205-SS) Sample Duplicate (DUP) 1205150421 Laboratory Control Sample (LCS)

The samples in this SDG were analyzed on a "dry weight" basis.

Data Summary:

There are no exceptions, anomalies or deviations from the specified methods. All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable.

Product: Liquid Scint Ni63, Solid Analytical Method: DOE RESL Ni-1, Modified Analytical Procedure: GL-RAD-A-022 REV# 19 Analytical Batch: 2295678 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2295010 The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 587450013 L1-12205A-FSGS-311-SS 587450014 L1-12205A-FSGS-312-SS 587450015 L1-12112A-FSGS-048-SS 587450016 L1-12112A-FSGS-061-SS 587450017 L1-12112A-FIGS-029-SS 587450018 L1-12112A-FIGS-031-SS 587450019 L1-12112A-QIGS-031-SS 587450020 L1-12112A-FIGS-032-SS 587450021 L1-12112A-FIGS-033-SS 1205150426 Method Blank (MB) 1205150427 587450013(L1-12205A-FSGS-311-SS) Sample Duplicate (DUP) 1205150428 Laboratory Control Sample (LCS)

Page 99 of 100 SDG: 587450

The samples in this SDG were analyzed on a "dry weight" basis.

Data Summary:

There are no exceptions, anomalies or deviations from the specified methods. All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Page 100 of 100 SDG: 587450

July 06, 2022 Mr. Gerry Wood Zion Solutions 100 Shiloh Blvd.

Zion, Illinois 60099 Re: Zion Solutions Work Order: 584595

Dear Mr. Wood:

GEL Laboratories, LLC (GEL) appreciates the opportunity to provide the enclosed analytical results for the sample(s) we received on June 30, 2022. This original data report has been prepared and reviewed in accordance with GELs standard operating procedures.

Test results for NELAP or ISO 17025 accredited tests are verified to meet the requirements of those standards, with any exceptions noted. The results reported relate only to the items tested and to the sample as received by the laboratory. These results may not be reproduced except as full reports without approval by the laboratory.

Copies of GELs accreditations and certifications can be found on our website at www.gel.com.

Our policy is to provide high quality, personalized analytical services to enable you to meet your analytical needs on time every time. We trust that you will find everything in order and to your satisfaction. If you have any questions, please do not hesitate to call me at (843) 556-8171, ext. 1605.

Sincerely, Marcellas PM_SIGN_HERE Knight for Zachary Worsham Project Manager Purchase Order: 702793 Enclosures Page 1 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Report for ENRG080 Zion Solutions (702793)

Client SDG: 584595 GEL Work Order: 584595 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a Tracer compound
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.

UI Gamma SpectroscopyUncertain identification Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

The designation ND, if present, appears in the result column when the analyte concentration is not detected above the limit as defined in the U qualifier above.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Zachary Worsham.

Reviewed by USER_SIGN_HERE Page 2 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-201-SS Project: ENRG08001 Sample ID: 584595001 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 3.78%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.384 +/-0.187 0.122 +/-0.190 pCi/g RXF2 07/01/22 1209 2284568 1 Bismuth-211 U 0.00928 +/-0.397 0.170 +/-0.409 pCi/g Bismuth-212 U 0.386 +/-0.408 0.514 +/-0.409 pCi/g Bismuth-214 0.217 +/-0.0810 0.0686 +/-0.0834 pCi/g Cesium-134 U 0.0151 +/-0.0204 0.0430 +/-0.0216 0.173 pCi/g Cesium-137 U 0.0198 +/-0.0223 0.0338 +/-0.0224 0.363 pCi/g Cobalt-60 U 0.00653 +/-0.0205 0.0417 +/-0.0207 0.109 pCi/g Europium-152 U 0.00350 +/-0.0474 0.0888 +/-0.0474 0.869 pCi/g Europium-154 U 0.00422 +/-0.0705 0.134 +/-0.0705 0.799 pCi/g Lead-212 0.233 +/-0.0599 0.0575 +/-0.0628 pCi/g Lead-214 0.314 +/-0.0790 0.130 +/-0.0830 pCi/g Potassium-40 9.73 +/-0.945 0.464 +/-1.28 pCi/g Thallium-208 0.0537 +/-0.0358 0.0412 +/-0.0362 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 3 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-201-SS Project: ENRG08001 Sample ID: 584595001 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 4 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FQGS-201-SS Project: ENRG08001 Sample ID: 584595002 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 3.61%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.570 +/-0.174 0.173 +/-0.183 pCi/g RXF2 07/04/22 1140 2284568 1 Bismuth-211 U 0.160 +/-0.678 0.273 +/-0.687 pCi/g Bismuth-212 U 0.601 +/-0.402 0.966 +/-0.488 pCi/g Bismuth-214 0.253 +/-0.0987 0.0984 +/-0.101 pCi/g Cesium-134 U -0.00272 +/-0.0262 0.0548 +/-0.0262 0.173 pCi/g Cesium-137 U 0.00378 +/-0.0287 0.0575 +/-0.0287 0.363 pCi/g Cobalt-60 U 0.0131 +/-0.0274 0.0653 +/-0.0280 0.109 pCi/g Europium-152 U -0.0258 +/-0.0703 0.135 +/-0.0713 0.869 pCi/g Europium-154 U -0.00410 +/-0.0784 0.164 +/-0.0784 0.799 pCi/g Lead-212 0.373 +/-0.0845 0.0685 +/-0.0899 pCi/g Lead-214 0.393 +/-0.136 0.199 +/-0.140 pCi/g Potassium-40 10.3 +/-1.34 0.576 +/-1.68 pCi/g Thallium-208 0.119 +/-0.0603 0.0487 +/-0.0613 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 5 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FQGS-201-SS Project: ENRG08001 Sample ID: 584595002 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 6 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-202-SS Project: ENRG08001 Sample ID: 584595003 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 3.99%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 UI 0.000 +/-0.141 0.156 +/-0.169 pCi/g RXF2 07/01/22 1210 2284568 1 Bismuth-211 UI 0.000 +/-0.165 0.230 +/-0.267 pCi/g Bismuth-212 U 0.356 +/-0.226 0.438 +/-0.279 pCi/g Bismuth-214 UI 0.000 +/-0.0718 0.0874 +/-0.0938 pCi/g Cesium-134 U 0.00180 +/-0.0180 0.0306 +/-0.0180 0.173 pCi/g Cesium-137 U 0.00264 +/-0.0154 0.0290 +/-0.0155 0.363 pCi/g Cobalt-60 U -0.00185 +/-0.0171 0.0302 +/-0.0171 0.109 pCi/g Europium-152 U -0.00513 +/-0.0355 0.0650 +/-0.0355 0.869 pCi/g Europium-154 U 0.00107 +/-0.0539 0.0990 +/-0.0539 0.799 pCi/g Lead-212 0.207 +/-0.0462 0.0367 +/-0.0491 pCi/g Lead-214 0.166 +/-0.0599 0.0557 +/-0.0614 pCi/g Potassium-40 12.1 +/-0.770 0.237 +/-1.33 pCi/g Thallium-208 U 0.0232 +/-0.0235 0.0267 +/-0.0236 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 7 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-202-SS Project: ENRG08001 Sample ID: 584595003 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 8 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-203-SS Project: ENRG08001 Sample ID: 584595004 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 4.61%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.335 +/-0.161 0.116 +/-0.164 pCi/g RXF2 07/01/22 1210 2284568 1 Bismuth-211 U 0.0650 +/-0.448 0.169 +/-0.456 pCi/g Bismuth-212 U 0.287 +/-0.343 0.427 +/-0.345 pCi/g Bismuth-214 0.225 +/-0.101 0.0633 +/-0.103 pCi/g Cesium-134 U 0.00491 +/-0.0182 0.0369 +/-0.0183 0.173 pCi/g Cesium-137 UI 0.000 +/-0.0442 0.0275 +/-0.0445 0.363 pCi/g Cobalt-60 U 0.00258 +/-0.0179 0.0360 +/-0.0180 0.109 pCi/g Europium-152 U -0.00390 +/-0.0446 0.0800 +/-0.0447 0.869 pCi/g Europium-154 U -0.0179 +/-0.0675 0.123 +/-0.0680 0.799 pCi/g Lead-212 0.289 +/-0.0541 0.0477 +/-0.0590 pCi/g Lead-214 0.294 +/-0.0773 0.115 +/-0.0811 pCi/g Potassium-40 10.6 +/-0.925 0.346 +/-1.32 pCi/g Thallium-208 0.0654 +/-0.0320 0.0296 +/-0.0326 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 9 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-203-SS Project: ENRG08001 Sample ID: 584595004 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 10 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-204-SS Project: ENRG08001 Sample ID: 584595005 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 4.02%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 UI 0.000 +/-0.118 0.251 +/-0.199 pCi/g RXF2 07/01/22 1211 2284568 1 Bismuth-211 UI 0.000 +/-0.187 0.286 +/-0.327 pCi/g Bismuth-212 UI 0.000 +/-0.393 0.430 +/-0.396 pCi/g Bismuth-214 UI 0.000 +/-0.0777 0.119 +/-0.122 pCi/g Cesium-134 U 0.0223 +/-0.0217 0.0478 +/-0.0240 0.173 pCi/g Cesium-137 U 0.0260 +/-0.0197 0.0430 +/-0.0230 0.363 pCi/g Cobalt-60 U -0.0173 +/-0.0220 0.0358 +/-0.0234 0.109 pCi/g Europium-152 U 0.0356 +/-0.0416 0.0896 +/-0.0447 0.869 pCi/g Europium-154 U 0.0124 +/-0.0600 0.121 +/-0.0603 0.799 pCi/g Lead-212 0.170 +/-0.0630 0.0521 +/-0.0647 pCi/g Lead-214 0.212 +/-0.0679 0.0615 +/-0.0702 pCi/g Potassium-40 10.4 +/-1.02 0.350 +/-1.42 pCi/g Thallium-208 0.0650 +/-0.0262 0.0355 +/-0.0268 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 11 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-204-SS Project: ENRG08001 Sample ID: 584595005 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 12 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-205-SS Project: ENRG08001 Sample ID: 584595006 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 5.03%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 UI 0.000 +/-0.151 0.191 +/-0.176 pCi/g RXF2 07/01/22 1211 2284568 1 Bismuth-211 UI 0.000 +/-0.118 0.245 +/-0.171 pCi/g Bismuth-212 U 0.168 +/-0.232 0.466 +/-0.245 pCi/g Bismuth-214 0.173 +/-0.0675 0.0581 +/-0.0691 pCi/g Cesium-134 U 0.0178 +/-0.0297 0.0401 +/-0.0308 0.173 pCi/g Cesium-137 U 0.00944 +/-0.0186 0.0342 +/-0.0191 0.363 pCi/g Cobalt-60 U 0.0234 +/-0.0235 0.0378 +/-0.0258 0.109 pCi/g Europium-152 U -0.0162 +/-0.0381 0.0709 +/-0.0389 0.869 pCi/g Europium-154 U 0.0559 +/-0.0849 0.126 +/-0.0887 0.799 pCi/g Lead-212 0.289 +/-0.0542 0.0394 +/-0.0589 pCi/g Lead-214 0.195 +/-0.0806 0.0615 +/-0.0821 pCi/g Potassium-40 10.5 +/-0.877 0.257 +/-1.33 pCi/g Thallium-208 0.0517 +/-0.0407 0.0299 +/-0.0409 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 13 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-205-SS Project: ENRG08001 Sample ID: 584595006 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 14 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-206-SS Project: ENRG08001 Sample ID: 584595007 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 5.89%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.324 +/-0.141 0.111 +/-0.144 pCi/g RXF2 07/01/22 1212 2284568 1 Bismuth-211 UI 0.000 +/-0.427 0.134 +/-0.433 pCi/g Bismuth-212 U 0.192 +/-0.206 0.438 +/-0.224 pCi/g Bismuth-214 UI 0.000 +/-0.0473 0.0978 +/-0.0669 pCi/g Cesium-134 U 0.0163 +/-0.0166 0.0358 +/-0.0182 0.173 pCi/g Cesium-137 U -0.00165 +/-0.0157 0.0296 +/-0.0157 0.363 pCi/g Cobalt-60 U 0.0192 +/-0.0192 0.0428 +/-0.0211 0.109 pCi/g Europium-152 U 0.00196 +/-0.0370 0.0705 +/-0.0370 0.869 pCi/g Europium-154 U 0.00284 +/-0.0495 0.0996 +/-0.0495 0.799 pCi/g Lead-212 0.246 +/-0.0470 0.0366 +/-0.0512 pCi/g Lead-214 0.297 +/-0.0749 0.103 +/-0.0790 pCi/g Potassium-40 9.72 +/-0.836 0.247 +/-1.24 pCi/g Thallium-208 0.0927 +/-0.0327 0.0245 +/-0.0337 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 15 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-206-SS Project: ENRG08001 Sample ID: 584595007 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 16 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-207-SS Project: ENRG08001 Sample ID: 584595008 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 3.83%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.144 +/-0.188 0.278 +/-0.199 pCi/g RXF2 07/01/22 1218 2284568 1 Bismuth-211 U 0.234 +/-0.173 0.361 +/-0.204 pCi/g Bismuth-212 U 0.322 +/-0.376 0.788 +/-0.404 pCi/g Bismuth-214 0.132 +/-0.0932 0.0887 +/-0.0940 pCi/g Cesium-134 U 0.00991 +/-0.0280 0.0563 +/-0.0284 0.173 pCi/g Cesium-137 U 0.00433 +/-0.0220 0.0444 +/-0.0221 0.363 pCi/g Cobalt-60 U -0.0174 +/-0.0309 0.0507 +/-0.0319 0.109 pCi/g Europium-152 U -0.0400 +/-0.0544 0.0955 +/-0.0574 0.869 pCi/g Europium-154 U -0.0307 +/-0.0706 0.132 +/-0.0720 0.799 pCi/g Lead-212 0.252 +/-0.0758 0.0591 +/-0.0782 pCi/g Lead-214 0.161 +/-0.132 0.0861 +/-0.132 pCi/g Potassium-40 9.34 +/-1.15 0.485 +/-1.43 pCi/g Thallium-208 0.0486 +/-0.0470 0.0353 +/-0.0472 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 17 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-207-SS Project: ENRG08001 Sample ID: 584595008 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 18 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-208-SS Project: ENRG08001 Sample ID: 584595009 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 3.63%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.246 +/-0.133 0.132 +/-0.135 pCi/g RXF2 07/01/22 1218 2284568 1 Bismuth-211 UI 0.000 +/-0.209 0.257 +/-0.284 pCi/g Bismuth-212 U 0.144 +/-0.239 0.482 +/-0.248 pCi/g Bismuth-214 0.182 +/-0.0658 0.0568 +/-0.0676 pCi/g Cesium-134 U 0.0328 +/-0.0206 0.0412 +/-0.0255 0.173 pCi/g Cesium-137 U -0.00632 +/-0.0162 0.0290 +/-0.0165 0.363 pCi/g Cobalt-60 U 0.00302 +/-0.0183 0.0369 +/-0.0184 0.109 pCi/g Europium-152 U -0.000334 +/-0.0402 0.0798 +/-0.0402 0.869 pCi/g Europium-154 U -0.00608 +/-0.0614 0.116 +/-0.0615 0.799 pCi/g Lead-212 0.168 +/-0.0647 0.0488 +/-0.0663 pCi/g Lead-214 0.152 +/-0.0758 0.0556 +/-0.0768 pCi/g Potassium-40 10.8 +/-0.893 0.187 +/-1.43 pCi/g Thallium-208 0.0411 +/-0.0270 0.0286 +/-0.0273 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 19 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-208-SS Project: ENRG08001 Sample ID: 584595009 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 20 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-209-SS Project: ENRG08001 Sample ID: 584595010 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 7.38%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.141 +/-0.165 0.244 +/-0.165 pCi/g RXF2 07/01/22 1219 2284568 1 Bismuth-211 UI 0.000 +/-0.345 0.427 +/-0.466 pCi/g Bismuth-212 U 0.404 +/-0.298 0.462 +/-0.300 pCi/g Bismuth-214 UI 0.000 +/-0.110 0.163 +/-0.152 pCi/g Cesium-134 U 0.0143 +/-0.0295 0.0575 +/-0.0302 0.173 pCi/g Cesium-137 UI 0.000 +/-0.0450 0.0421 +/-0.0460 0.363 pCi/g Cobalt-60 U -0.0104 +/-0.0242 0.0462 +/-0.0246 0.109 pCi/g Europium-152 U 0.0529 +/-0.0602 0.123 +/-0.0649 0.869 pCi/g Europium-154 U -0.0374 +/-0.0980 0.158 +/-0.0995 0.799 pCi/g Lead-212 0.261 +/-0.102 0.0624 +/-0.104 pCi/g Lead-214 0.247 +/-0.125 0.0953 +/-0.127 pCi/g Potassium-40 9.63 +/-1.20 0.562 +/-1.49 pCi/g Thallium-208 0.0752 +/-0.0460 0.0455 +/-0.0465 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 21 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-209-SS Project: ENRG08001 Sample ID: 584595010 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 22 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-210-SS Project: ENRG08001 Sample ID: 584595011 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 6.52%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.307 +/-0.218 0.315 +/-0.260 pCi/g RXF2 07/01/22 1219 2284568 1 Bismuth-211 UI 0.000 +/-0.305 0.379 +/-0.499 pCi/g Bismuth-212 U 0.526 +/-0.379 0.832 +/-0.450 pCi/g Bismuth-214 UI 0.000 +/-0.0983 0.171 +/-0.150 pCi/g Cesium-134 U 0.0176 +/-0.0301 0.0637 +/-0.0312 0.173 pCi/g Cesium-137 U 0.0302 +/-0.0296 0.0496 +/-0.0297 0.363 pCi/g Cobalt-60 U 0.0222 +/-0.0319 0.0691 +/-0.0335 0.109 pCi/g Europium-152 U 0.0383 +/-0.0532 0.105 +/-0.0561 0.869 pCi/g Europium-154 U 0.0450 +/-0.0856 0.179 +/-0.0880 0.799 pCi/g Lead-212 0.354 +/-0.0659 0.0524 +/-0.0724 pCi/g Lead-214 0.313 +/-0.111 0.0684 +/-0.113 pCi/g Potassium-40 8.05 +/-1.08 0.492 +/-1.28 pCi/g Thallium-208 0.125 +/-0.0472 0.0417 +/-0.0488 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 23 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-210-SS Project: ENRG08001 Sample ID: 584595011 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 24 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-211-SS Project: ENRG08001 Sample ID: 584595012 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 5.47%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.219 +/-0.185 0.138 +/-0.186 pCi/g RXF2 07/01/22 1220 2284568 1 Bismuth-211 UI 0.000 +/-0.276 0.323 +/-0.429 pCi/g Bismuth-212 U 0.448 +/-0.286 0.638 +/-0.353 pCi/g Bismuth-214 0.247 +/-0.0772 0.0626 +/-0.0800 pCi/g Cesium-134 U 0.0372 +/-0.0207 0.0491 +/-0.0269 0.173 pCi/g Cesium-137 U 0.0336 +/-0.0289 0.0406 +/-0.0290 0.363 pCi/g Cobalt-60 U 0.00881 +/-0.0211 0.0457 +/-0.0215 0.109 pCi/g Europium-152 U -0.00838 +/-0.0463 0.0899 +/-0.0465 0.869 pCi/g Europium-154 U 0.0302 +/-0.0587 0.129 +/-0.0603 0.799 pCi/g Lead-212 0.318 +/-0.0689 0.0541 +/-0.0745 pCi/g Lead-214 0.260 +/-0.100 0.0678 +/-0.103 pCi/g Potassium-40 7.12 +/-0.819 0.258 +/-1.08 pCi/g Thallium-208 0.100 +/-0.0450 0.0315 +/-0.0458 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 25 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-211-SS Project: ENRG08001 Sample ID: 584595012 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 26 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-211-SB Project: ENRG08001 Sample ID: 584595013 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 5.54%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.274 +/-0.190 0.135 +/-0.191 pCi/g RXF2 07/01/22 1220 2284568 1 Bismuth-211 UI 0.000 +/-0.255 0.327 +/-0.403 pCi/g Bismuth-212 U 0.185 +/-0.289 0.592 +/-0.302 pCi/g Bismuth-214 0.243 +/-0.116 0.0762 +/-0.118 pCi/g Cesium-134 U 0.000842 +/-0.0258 0.0482 +/-0.0258 0.173 pCi/g Cesium-137 U 0.0245 +/-0.0362 0.0383 +/-0.0363 0.363 pCi/g Cobalt-60 U -0.0175 +/-0.0193 0.0307 +/-0.0209 0.109 pCi/g Europium-152 U 0.00781 +/-0.0411 0.0836 +/-0.0413 0.869 pCi/g Europium-154 U -0.0287 +/-0.0671 0.104 +/-0.0683 0.799 pCi/g Lead-212 0.283 +/-0.0562 0.0471 +/-0.0610 pCi/g Lead-214 0.247 +/-0.0924 0.0691 +/-0.0947 pCi/g Potassium-40 8.32 +/-0.909 0.362 +/-1.15 pCi/g Thallium-208 0.0922 +/-0.0465 0.0373 +/-0.0474 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 27 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-211-SB Project: ENRG08001 Sample ID: 584595013 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 28 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-212-SS Project: ENRG08001 Sample ID: 584595014 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 3.99%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 UI 0.000 +/-0.142 0.200 +/-0.172 pCi/g RXF2 07/01/22 1221 2284568 1 Bismuth-211 U 0.00847 +/-0.475 0.151 +/-0.482 pCi/g Bismuth-212 U 0.232 +/-0.282 0.583 +/-0.302 pCi/g Bismuth-214 UI 0.000 +/-0.0859 0.112 +/-0.117 pCi/g Cesium-134 U 0.0341 +/-0.0898 0.0430 +/-0.0911 0.173 pCi/g Cesium-137 U 0.00254 +/-0.0188 0.0368 +/-0.0189 0.363 pCi/g Cobalt-60 U -0.00499 +/-0.0191 0.0360 +/-0.0192 0.109 pCi/g Europium-152 U -0.0119 +/-0.0417 0.0783 +/-0.0421 0.869 pCi/g Europium-154 U 0.0901 +/-0.0704 0.158 +/-0.0817 0.799 pCi/g Lead-212 0.127 +/-0.0612 0.0529 +/-0.0621 pCi/g Lead-214 0.257 +/-0.0821 0.107 +/-0.0848 pCi/g Potassium-40 10.9 +/-0.944 0.267 +/-1.45 pCi/g Thallium-208 0.0694 +/-0.0441 0.0265 +/-0.0445 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 29 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-212-SS Project: ENRG08001 Sample ID: 584595014 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 30 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-213-SS Project: ENRG08001 Sample ID: 584595015 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 2.96%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.224 +/-0.142 0.114 +/-0.144 pCi/g RXF2 07/01/22 1221 2284568 1 Bismuth-211 U 0.0630 +/-0.365 0.162 +/-0.369 pCi/g Bismuth-212 U 0.141 +/-0.291 0.437 +/-0.291 pCi/g Bismuth-214 0.180 +/-0.0578 0.0564 +/-0.0597 pCi/g Cesium-134 U 0.0123 +/-0.0184 0.0383 +/-0.0192 0.173 pCi/g Cesium-137 U 0.00498 +/-0.0158 0.0319 +/-0.0159 0.363 pCi/g Cobalt-60 U -0.0110 +/-0.0207 0.0371 +/-0.0213 0.109 pCi/g Europium-152 U 0.00248 +/-0.0415 0.0762 +/-0.0416 0.869 pCi/g Europium-154 U 0.000967 +/-0.0578 0.114 +/-0.0578 0.799 pCi/g Lead-212 0.255 +/-0.0536 0.0463 +/-0.0582 pCi/g Lead-214 0.194 +/-0.0643 0.106 +/-0.0662 pCi/g Potassium-40 10.9 +/-0.943 0.288 +/-1.42 pCi/g Thallium-208 0.0978 +/-0.0290 0.0247 +/-0.0302 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 31 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-213-SS Project: ENRG08001 Sample ID: 584595015 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 32 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-214-SS Project: ENRG08001 Sample ID: 584595016 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 2.46%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.316 +/-0.0982 0.0855 +/-0.104 pCi/g RXF2 07/01/22 1222 2284568 1 Bismuth-211 0.334 +/-0.324 0.127 +/-0.327 pCi/g Bismuth-212 U 0.159 +/-0.190 0.406 +/-0.203 pCi/g Bismuth-214 0.173 +/-0.0645 0.0440 +/-0.0670 pCi/g Cesium-134 U 0.00616 +/-0.0139 0.0291 +/-0.0142 0.173 pCi/g Cesium-137 U 0.00133 +/-0.0135 0.0270 +/-0.0135 0.363 pCi/g Cobalt-60 U -0.00490 +/-0.0169 0.0303 +/-0.0170 0.109 pCi/g Europium-152 U -0.0260 +/-0.0365 0.0628 +/-0.0384 0.869 pCi/g Europium-154 U 0.00134 +/-0.0515 0.0974 +/-0.0516 0.799 pCi/g Lead-212 0.241 +/-0.0476 0.0367 +/-0.0559 pCi/g Lead-214 0.214 +/-0.0632 0.0923 +/-0.0661 pCi/g Potassium-40 10.9 +/-0.813 0.140 +/-1.25 pCi/g Thallium-208 0.0682 +/-0.0289 0.0248 +/-0.0297 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 33 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-214-SS Project: ENRG08001 Sample ID: 584595016 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 34 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-215-SS Project: ENRG08001 Sample ID: 584595017 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 6.29%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.312 +/-0.146 0.117 +/-0.149 pCi/g RXF2 07/01/22 1222 2284568 1 Bismuth-211 UI 0.000 +/-0.449 0.125 +/-0.459 pCi/g Bismuth-212 U 0.0614 +/-0.276 0.542 +/-0.278 pCi/g Bismuth-214 0.211 +/-0.0830 0.0579 +/-0.0856 pCi/g Cesium-134 U 0.00988 +/-0.0152 0.0328 +/-0.0159 0.173 pCi/g Cesium-137 0.0400 +/-0.0345 0.0325 +/-0.0347 0.363 pCi/g Cobalt-60 U -0.00798 +/-0.0171 0.0323 +/-0.0175 0.109 pCi/g Europium-152 U 0.0140 +/-0.0392 0.0740 +/-0.0398 0.869 pCi/g Europium-154 U -0.0455 +/-0.0599 0.0916 +/-0.0635 0.799 pCi/g Lead-212 0.294 +/-0.0515 0.0391 +/-0.0609 pCi/g Lead-214 0.379 +/-0.0861 0.128 +/-0.0921 pCi/g Potassium-40 8.64 +/-0.829 0.338 +/-1.14 pCi/g Thallium-208 0.109 +/-0.0395 0.0292 +/-0.0410 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 35 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-215-SS Project: ENRG08001 Sample ID: 584595017 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 36 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-216-SS Project: ENRG08001 Sample ID: 584595018 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 7.73%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.273 +/-0.232 0.190 +/-0.234 pCi/g RXF2 07/01/22 1222 2284568 1 Bismuth-211 UI 0.000 +/-0.284 0.377 +/-0.527 pCi/g Bismuth-212 U 0.407 +/-0.320 0.703 +/-0.371 pCi/g Bismuth-214 0.184 +/-0.0908 0.0906 +/-0.0921 pCi/g Cesium-134 U 0.0422 +/-0.0420 0.0547 +/-0.0463 0.173 pCi/g Cesium-137 0.0728 +/-0.0400 0.0418 +/-0.0404 0.363 pCi/g Cobalt-60 U 0.0218 +/-0.0255 0.0584 +/-0.0274 0.109 pCi/g Europium-152 U 0.0356 +/-0.0586 0.121 +/-0.0609 0.869 pCi/g Europium-154 U 0.0193 +/-0.0693 0.143 +/-0.0698 0.799 pCi/g Lead-212 0.333 +/-0.0687 0.0598 +/-0.0757 pCi/g Lead-214 0.351 +/-0.103 0.0797 +/-0.108 pCi/g Potassium-40 8.60 +/-1.05 0.431 +/-1.36 pCi/g Thallium-208 0.110 +/-0.0396 0.0363 +/-0.0407 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 37 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-216-SS Project: ENRG08001 Sample ID: 584595018 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 38 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-216-SB Project: ENRG08001 Sample ID: 584595019 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 7.52%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.207 +/-0.191 0.253 +/-0.213 pCi/g RXF2 07/01/22 1226 2284568 1 Bismuth-211 UI 0.000 +/-0.321 0.366 +/-0.418 pCi/g Bismuth-212 UI 0.000 +/-0.351 0.385 +/-0.360 pCi/g Bismuth-214 0.294 +/-0.0994 0.0726 +/-0.102 pCi/g Cesium-134 U -0.00242 +/-0.0211 0.0406 +/-0.0211 0.173 pCi/g Cesium-137 0.0481 +/-0.0421 0.0355 +/-0.0423 0.363 pCi/g Cobalt-60 U -0.0145 +/-0.0196 0.0346 +/-0.0207 0.109 pCi/g Europium-152 U 0.00818 +/-0.0548 0.105 +/-0.0550 0.869 pCi/g Europium-154 U 0.0376 +/-0.0734 0.156 +/-0.0754 0.799 pCi/g Lead-212 0.209 +/-0.0937 0.0621 +/-0.0956 pCi/g Lead-214 0.212 +/-0.117 0.0709 +/-0.118 pCi/g Potassium-40 6.17 +/-0.940 0.400 +/-1.11 pCi/g Thallium-208 0.0700 +/-0.0420 0.0362 +/-0.0424 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 39 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-216-SB Project: ENRG08001 Sample ID: 584595019 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 40 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-217-SS Project: ENRG08001 Sample ID: 584595020 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 4.84%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 U 0.122 +/-0.162 0.221 +/-0.172 pCi/g RXF2 07/01/22 1227 2284568 1 Bismuth-211 UI 0.000 +/-0.479 0.172 +/-0.485 pCi/g Bismuth-212 U 0.365 +/-0.389 0.429 +/-0.390 pCi/g Bismuth-214 0.192 +/-0.0781 0.0703 +/-0.0800 pCi/g Cesium-134 U 0.00623 +/-0.0218 0.0423 +/-0.0220 0.173 pCi/g Cesium-137 U 0.0367 +/-0.0241 0.0476 +/-0.0294 0.363 pCi/g Cobalt-60 U -0.00889 +/-0.0191 0.0353 +/-0.0196 0.109 pCi/g Europium-152 U -0.0160 +/-0.0445 0.0848 +/-0.0451 0.869 pCi/g Europium-154 U -0.00332 +/-0.0593 0.116 +/-0.0594 0.799 pCi/g Lead-212 0.217 +/-0.0531 0.0479 +/-0.0561 pCi/g Lead-214 0.292 +/-0.0845 0.121 +/-0.0880 pCi/g Potassium-40 9.13 +/-0.890 0.276 +/-1.23 pCi/g Thallium-208 UI 0.000 +/-0.0468 0.0295 +/-0.0469 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1501 2284252 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 41 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-217-SS Project: ENRG08001 Sample ID: 584595020 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 42 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-218-SS Project: ENRG08001 Sample ID: 584595021 Client ID: ENRG080 Matrix: Soil Collect Date: 14-JUN-22 Receive Date: 30-JUN-22 Collector: Client Moisture: 3.23%

Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Rad Gamma Spec Analysis Gammaspec, Gamma, Solid (Requested List) "Dry Weight Corrected" Actinium-228 0.162 +/-0.126 0.157 +/-0.127 pCi/g RXF2 07/01/22 1740 2284624 1 Bismuth-211 U 0.0137 +/-0.608 0.177 +/-0.612 pCi/g Bismuth-212 U 0.226 +/-0.264 0.580 +/-0.283 pCi/g Bismuth-214 0.172 +/-0.0943 0.0781 +/-0.0955 pCi/g Cesium-134 U 0.00495 +/-0.0240 0.0494 +/-0.0241 0.173 pCi/g Cesium-137 U -0.00487 +/-0.0213 0.0395 +/-0.0214 0.363 pCi/g Cobalt-60 U -0.0269 +/-0.0250 0.0379 +/-0.0279 0.109 pCi/g Europium-152 U 0.0115 +/-0.0529 0.0988 +/-0.0531 0.869 pCi/g Europium-154 U 0.0465 +/-0.0860 0.167 +/-0.0886 0.799 pCi/g Lead-212 0.311 +/-0.0633 0.0502 +/-0.0683 pCi/g Lead-214 0.230 +/-0.100 0.123 +/-0.102 pCi/g Potassium-40 10.9 +/-1.10 0.389 +/-1.53 pCi/g Thallium-208 0.0706 +/-0.0460 0.0345 +/-0.0464 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 SF1 06/30/22 1504 2284254 The following Analytical Methods were performed Method Description 1 DOE HASL 300, 4.5.2.3/Ga-01-R Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Page 43 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Zion Solutions Address : 100 Shiloh Blvd.

Zion, Illinois 60099 Report Date: July 6, 2022

Contact:

Mr. Gerry Wood Project: Zion Solutions Client Sample ID: L1-10202D-FSGS-218-SS Project: ENRG08001 Sample ID: 584595021 Client ID: ENRG080 Parameter Qualifier Result Uncertainty MDC TPU RL Units PF DF Analyst Date Time Batch Mtd.

Surrogate/Tracer Recovery Test Batch ID Recovery% Acceptable Limits Notes:

The MDC is a sample specific MDC.

TPU is calculated at the 95% confidence level (1.96-sigma).

Column headers are defined as follows:

DF: Dilution Factor Mtd.: Method DL: Detection Limit PF: Prep Factor Lc/LC: Critical Level RL: Reporting Limit MDA: Minimum Detectable Activity TPU: Total Propagated Uncertainty MDC: Minimum Detectable Concentration Page 44 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: July 6, 2022 Client : Zion Solutions Page 1 of 7 100 Shiloh Blvd.

Zion, Illinois

Contact:

Mr. Gerry Wood Workorder: 584595 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2284568 QC1205129732 584595001 DUP Actinium-228 0.384 0.273 pCi/g 33.7 (0% - 100%) RXF2 07/01/22 14:28 Uncert: +/-0.187 +/-0.142 TPU: +/-0.190 +/-0.144 Bismuth-211 U 0.00928 U 0.0686 pCi/g 0 N/A Uncert: +/-0.397 +/-0.579 TPU: +/-0.409 +/-0.586 Bismuth-212 U 0.386 U -0.0812 pCi/g 0 N/A Uncert: +/-0.408 +/-0.301 TPU: +/-0.409 +/-0.303 Bismuth-214 0.217 0.264 pCi/g 19.5 (0% - 100%)

Uncert: +/-0.0810 +/-0.0965 TPU: +/-0.0834 +/-0.0990 Cesium-134 U 0.0151 U 0.0542 pCi/g 0 N/A Uncert: +/-0.0204 +/-0.0346 TPU: +/-0.0216 +/-0.0426 Cesium-137 U 0.0198 U 0.0173 pCi/g 0 N/A Uncert: +/-0.0223 +/-0.0187 TPU: +/-0.0224 +/-0.0203 Cobalt-60 U 0.00653 U -0.0153 pCi/g 0 N/A Uncert: +/-0.0205 +/-0.0224 TPU: +/-0.0207 +/-0.0234 Europium-152 U 0.00350 U 0.0317 pCi/g 0 N/A Uncert: +/-0.0474 +/-0.0580 TPU: +/-0.0474 +/-0.0599 Europium-154 U 0.00422 U 0.0209 pCi/g 0 N/A Uncert: +/-0.0705 +/-0.0760 TPU: +/-0.0705 +/-0.0766 Lead-212 0.233 0.328 pCi/g 34 * (0%-20%)

Uncert: +/-0.0599 +/-0.0654 TPU: +/-0.0628 +/-0.0724 Lead-214 0.314 0.288 pCi/g 8.78 (0% - 100%)

Uncert: +/-0.0790 +/-0.110 TPU: +/-0.0830 +/-0.113 Potassium-40 9.73 9.14 pCi/g 6.22 (0%-20%)

Uncert: +/-0.945 +/-0.995 TPU: +/-1.28 +/-1.36 Thallium-208 0.0537 0.0925 pCi/g 53.2 (0% - 100%)

Uncert: +/-0.0358 +/-0.0408 TPU: +/-0.0362 +/-0.0415 QC1205129733 LCS Americium-241 485 538 pCi/g 111 (75%-125%) RXF2 07/01/22 14:48 Page 45 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 584595 Page 2 of 7 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2284568 Uncert: +/-9.04 TPU: +/-47.7 Actinium-228 U -0.827 pCi/g Uncert: +/-1.79 TPU: +/-1.83 Bismuth-211 U -0.319 pCi/g Uncert: +/-2.23 TPU: +/-2.23 Bismuth-212 U 1.09 pCi/g Uncert: +/-4.52 TPU: +/-4.54 Bismuth-214 U 0.550 pCi/g Uncert: +/-0.649 TPU: +/-0.696 Cesium-134 U 0.0266 pCi/g Uncert: +/-0.417 TPU: +/-0.417 Cesium-137 157 154 pCi/g 97.8 (75%-125%)

Uncert: +/-2.74 TPU: +/-13.3 Cobalt-60 75.4 73.2 pCi/g 97 (75%-125%)

Uncert: +/-2.31 TPU: +/-6.94 Europium-152 U 0.611 pCi/g Uncert: +/-1.11 TPU: +/-1.14 Europium-154 U -0.446 pCi/g Uncert: +/-0.634 TPU: +/-0.666 Lead-212 U 0.272 pCi/g Uncert: +/-0.548 TPU: +/-0.562 Lead-214 U -0.299 pCi/g Uncert: +/-0.842 TPU: +/-0.853 Potassium-40 U -1.00 pCi/g Uncert: +/-1.71 TPU: +/-1.77 Thallium-208 U -0.125 pCi/g Uncert: +/-0.340 TPU: +/-0.345 QC1205129731 MB Actinium-228 U 0.0189 pCi/g RXF2 07/01/2212:27 Uncert: +/-0.100 TPU: +/-0.101 Bismuth-211 U 0.0918 pCi/g Page 46 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 584595 Page 3 of 7 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2284568 Uncert: +/-0.136 TPU: +/-0.136 Bismuth-212 U -0.00854 pCi/g Uncert: +/-0.171 TPU: +/-0.171 Bismuth-214 U 0.000333 pCi/g Uncert: +/-0.0311 TPU: +/-0.0311 Cesium-134 U -0.00527 pCi/g Uncert: +/-0.0130 TPU: +/-0.0132 Cesium-137 U -0.00591 pCi/g Uncert: +/-0.0145 TPU: +/-0.0148 Cobalt-60 U -0.00192 pCi/g Uncert: +/-0.0110 TPU: +/-0.0110 Europium-152 U -0.00728 pCi/g Uncert: +/-0.0330 TPU: +/-0.0332 Europium-154 U 0.0100 pCi/g Uncert: +/-0.0315 TPU: +/-0.0318 Lead-212 U 0.0493 pCi/g Uncert: +/-0.0567 TPU: +/-0.0610 Lead-214 U 0.0333 pCi/g Uncert: +/-0.0493 TPU: +/-0.0516 Potassium-40 U 0.0731 pCi/g Uncert: +/-0.198 TPU: +/-0.201 Thallium-208 U -0.00565 pCi/g Uncert: +/-0.0154 TPU: +/-0.0156 Batch 2284624 QC1205129814 584595021 DUP Actinium-228 0.162 U 0.0166 pCi/g 22.1 (0% - 100%) RXF2 07/01/2219:17 Uncert: +/-0.126 +/-0.135 TPU: +/-0.127 +/-0.135 Bismuth-211 U 0.0137 UI 0.000 pCi/g 0 N/A Uncert: +/-0.608 +/-0.493 TPU: +/-0.612 +/-0.495 Bismuth-212 U 0.226 U 0.159 pCi/g 0 N/A Uncert: +/-0.264 +/-0.222 TPU: +/-0.283 +/-0.234 Page 47 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 584595 Page 4 of 7 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2284624 Bismuth-214 0.172 0.168 pCi/g 2.47 (0% - 100%)

Uncert: +/-0.0943 +/-0.0743 TPU: +/-0.0955 +/-0.0759 Cesium-134 U 0.00495 U 0.0123 pCi/g 0 N/A Uncert: +/-0.0240 +/-0.0170 TPU: +/-0.0241 +/-0.0179 Cesium-137 U -0.00487 U 0.0173 pCi/g 0 N/A Uncert: +/-0.0213 +/-0.0165 TPU: +/-0.0214 +/-0.0183 Cobalt-60 U -0.0269 U 0.00531 pCi/g 0 N/A Uncert: +/-0.0250 +/-0.0177 TPU: +/-0.0279 +/-0.0179 Europium-152 U 0.0115 U -0.0144 pCi/g 0 N/A Uncert: +/-0.0529 +/-0.0476 TPU: +/-0.0531 +/-0.0481 Europium-154 U 0.0465 U -0.0260 pCi/g 0 N/A Uncert: +/-0.0860 +/-0.0608 TPU: +/-0.0886 +/-0.0619 Lead-212 0.311 0.161 pCi/g 63.5 * (0%-20%)

Uncert: +/-0.0633 +/-0.0634 TPU: +/-0.0683 +/-0.0647 Lead-214 0.230 0.238 pCi/g 3.29 (0% - 100%)

Uncert: +/-0.100 +/-0.0836 TPU: +/-0.102 +/-0.0858 Potassium-40 10.9 11.6 pCi/g 6.68 (0%-20%)

Uncert: +/-1.10 +/-0.913 TPU: +/-1.53 +/-1.38 Thallium-208 0.0706 0.0477 pCi/g 38.8 (0% - 100%)

Uncert: +/-0.0460 +/-0.0289 TPU: +/-0.0464 +/-0.0292 QC1205129815 LCS Americium-241 485 540 pCi/g 111 (75%-125%) RXF2 07/01/2219:19 Uncert: +/-8.82 TPU: +/-47.8 Actinium-228 U 1.40 pCi/g Uncert: +/-1.81 TPU: +/-1.92 Bismuth-211 U 0.230 pCi/g Uncert: +/-2.01 TPU: +/-2.01 Bismuth-212 U -0.521 pCi/g Uncert: +/-4.48 TPU: +/-4.48 Bismuth-214 U -0.333 pCi/g Uncert: +/-0.690 TPU: +/-0.706 Page 48 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 584595 Page 5 of 7 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2284624 Cesium-134 U 0.161 pCi/g Uncert: +/-0.404 TPU: +/-0.411 Cesium-137 157 152 pCi/g 96.6 (75%-125%)

Uncert: +/-2.74 TPU: +/-13.2 Cobalt-60 75.4 72.1 pCi/g 95.6 (75%-125%)

Uncert: +/-2.29 TPU: +/-6.84 Europium-152 U -0.175 pCi/g Uncert: +/-1.03 TPU: +/-1.04 Europium-154 U -0.104 pCi/g Uncert: +/-0.658 TPU: +/-0.660 Lead-212 U -0.00932 pCi/g Uncert: +/-0.563 TPU: +/-0.563 Lead-214 U 0.721 pCi/g Uncert: +/-1.50 TPU: +/-1.53 Potassium-40 U 0.101 pCi/g Uncert: +/-1.63 TPU: +/-1.63 Thallium-208 U 0.100 pCi/g Uncert: +/-0.349 TPU: +/-0.352 QC1205129813 MB Actinium-228 U -0.0255 pCi/g RXF2 07/01/2217:41 Uncert: +/-0.0626 TPU: +/-0.0637 Bismuth-211 U -0.0680 pCi/g Uncert: +/-0.0866 TPU: +/-0.0920 Bismuth-212 U 0.0587 pCi/g Uncert: +/-0.202 TPU: +/-0.204 Bismuth-214 U 0.0476 pCi/g Uncert: +/-0.0587 TPU: +/-0.0589 Cesium-134 U 0.000389 pCi/g Uncert: +/-0.0158 TPU: +/-0.0158 Cesium-137 U 0.00709 pCi/g Uncert: +/-0.00976 TPU: +/-0.0103 Page 49 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 584595 Page 6 of 7 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 2284624 Cobalt-60 U -0.00341 pCi/g Uncert: +/-0.00724 TPU: +/-0.00741 Europium-152 U -0.0247 pCi/g Uncert: +/-0.0400 TPU: +/-0.0416 Europium-154 U 0.00345 pCi/g Uncert: +/-0.0361 TPU: +/-0.0361 Lead-212 U 0.0119 pCi/g Uncert: +/-0.0448 TPU: +/-0.0451 Lead-214 U -0.0268 pCi/g Uncert: +/-0.0312 TPU: +/-0.0336 Potassium-40 U 0.106 pCi/g Uncert: +/-0.233 TPU: +/-0.234 Thallium-208 U 0.00215 pCi/g Uncert: +/-0.0149 TPU: +/-0.0149 Notes:

TPU and Counting Uncertainty are calculated at the 95% confidence level (1.96-sigma).

The Qualifiers in this report are defined as follows:

    • Analyte is a Tracer compound

< Result is less than value reported

> Result is greater than value reported BD Results are either below the MDC or tracer recovery is low FA Failed analysis.

H Analytical holding time was exceeded J See case narrative for an explanation J Value is estimated K Analyte present. Reported value may be biased high. Actual value is expected to be lower.

L Analyte present. Reported value may be biased low. Actual value is expected to be higher.

M M if above MDC and less than LLD M REMP Result > MDC/CL and < RDL N/A RPD or %Recovery limits do not apply.

N1 See case narrative ND Analyte concentration is not detected above the detection limit NJ Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Q One or more quality control criteria have not been met. Refer to the applicable narrative or DER.

R Sample results are rejected Page 50 of 60 SDG: 584595

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 584595 Page 7 of 7 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time U Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.

UI Gamma Spectroscopy--Uncertain identification UJ Gamma Spectroscopy--Uncertain identification UL Not considered detected. The associated number is the reported concentration, which may be inaccurate due to a low bias.

X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y Other specific qualifiers were required to properly define the results. Consult case narrative.

^ RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more or %RPD not applicable.

    • Indicates analyte is a surrogate/tracer compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

Page 51 of 60 SDG: 584595

Page 52 of 60 SDG: 584595 Page 53 of 60 SDG: 584595 Page 54 of 60 SDG: 584595 Page 55 of 60 SDG: 584595 List of current GEL Certifications as of 06 July 2022 State Certification Alabama 42200 Alaska 17018 Alaska Drinking Water SC00012 Arkansas 880651 CLIA 42D0904046 California 2940 Colorado SC00012 Connecticut PH0169 DoD ELAP/ ISO17025 A2LA 2567.01 Florida NELAP E87156 Foreign Soils Permit P3301500283, P3301500253 Georgia SC00012 Georgia SDWA 967 Hawaii SC00012 Idaho SC00012 Illinois NELAP 200029 Indiana CSC01 Kansas NELAP E10332 Kentucky SDWA 90129 Kentucky Wastewater 90129 Louisiana Drinking Water LA024 Louisiana NELAP 03046 (AI33904)

Maine 2019020 Maryland 270 Massachusetts MSC012 Massachusetts PFAS Approv Letter Michigan 9976 Mississippi SC00012 Nebraska NEOS2613 Nevada SC0001220225 New Hampshire NELAP 2054 New Jersey NELAP SC002 New Mexico SC00012 New York NELAP 11501 North Carolina 233 North Carolina SDWA 45709 North Dakota R158 Oklahoma 2019165 Pennsylvania NELAP 6800485 Puerto Rico SC00012 S. Carolina Radiochem 10120002 Sanitation Districts of L 9255651 South Carolina Chemistry 10120001 Tennessee TN 02934 Texas NELAP T1047042352220 Utah NELAP SC00012202136 Vermont VT87156 Virginia NELAP 460202 Washington C780 Page 56 of 60 SDG: 584595

Radiochemistry Technical Case Narrative Zion Solutions SDG #: 584595 Product: Dry Weight Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2284254 The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 584595021 L1-10202D-FSGS-218-SS The samples in this SDG were analyzed on an "as received" basis.

Data Summary:

There are no exceptions, anomalies or deviations from the specified methods. All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable.

Product: Gammaspec, Gamma, Solid (Requested List)

Analytical Method: DOE HASL 300, 4.5.2.3/Ga-01-R Analytical Procedure: GL-RAD-A-013 REV# 27 Analytical Batch: 2284568 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2284252 The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 584595001 L1-10202D-FSGS-201-SS 584595002 L1-10202D-FQGS-201-SS 584595003 L1-10202D-FSGS-202-SS 584595004 L1-10202D-FSGS-203-SS 584595005 L1-10202D-FSGS-204-SS 584595006 L1-10202D-FSGS-205-SS 584595007 L1-10202D-FSGS-206-SS 584595008 L1-10202D-FSGS-207-SS 584595009 L1-10202D-FSGS-208-SS 584595010 L1-10202D-FSGS-209-SS 584595011 L1-10202D-FSGS-210-SS 584595012 L1-10202D-FSGS-211-SS 584595013 L1-10202D-FSGS-211-SB Page 57 of 60 SDG: 584595

584595014 L1-10202D-FSGS-212-SS 584595015 L1-10202D-FSGS-213-SS 584595016 L1-10202D-FSGS-214-SS 584595017 L1-10202D-FSGS-215-SS 584595018 L1-10202D-FSGS-216-SS 584595019 L1-10202D-FSGS-216-SB 584595020 L1-10202D-FSGS-217-SS 1205129731 Method Blank (MB) 1205129732 584595001(L1-10202D-FSGS-201-SS) Sample Duplicate (DUP) 1205129733 Laboratory Control Sample (LCS)

The samples in this SDG were analyzed on a "dry weight" basis.

Data Summary:

All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable, with the following exceptions.

Quality Control (QC) Information Duplication Criteria between QC Sample and Duplicate Sample The Sample and the Duplicate, (See Below), did not meet the relative percent difference requirement; however, they do meet the relative error ratio requirement with the value listed below.

Sample Analyte Value 1205129732 (L1-10202D-FSGS-201-SSDUP) Lead-212 RPD 34* (0.00%-20.00%) RER 1.95 (0-3)

Technical Information Recounts Sample was recounted due to a detector error. The recount is being reported. 584595002 (L1-10202D-FQGS-201-SS).

Qualifier Information Qualifier Reason Analyte Sample Client Sample Results are considered a false UI positive due to high counting Bismuth-211 584595007 L1-10202D-FSGS-206-SS uncertainty.

Bismuth-211 584595017 L1-10202D-FSGS-215-SS Bismuth-211 584595020 L1-10202D-FSGS-217-SS Thallium-208 584595020 L1-10202D-FSGS-217-SS Results are considered a false UI positive due to high Bismuth-212 584595005 L1-10202D-FSGS-204-SS peak-width.

Page 58 of 60 SDG: 584595

Bismuth-212 584595019 L1-10202D-FSGS-216-SB Cesium-137 584595004 L1-10202D-FSGS-203-SS Cesium-137 584595010 L1-10202D-FSGS-209-SS Results are considered a false UI Actinium-228 584595003 L1-10202D-FSGS-202-SS positive due to low abundance.

Actinium-228 584595005 L1-10202D-FSGS-204-SS Actinium-228 584595006 L1-10202D-FSGS-205-SS Actinium-228 584595014 L1-10202D-FSGS-212-SS Bismuth-211 584595003 L1-10202D-FSGS-202-SS Bismuth-211 584595005 L1-10202D-FSGS-204-SS Bismuth-211 584595006 L1-10202D-FSGS-205-SS Bismuth-211 584595009 L1-10202D-FSGS-208-SS Bismuth-211 584595010 L1-10202D-FSGS-209-SS Bismuth-211 584595011 L1-10202D-FSGS-210-SS Bismuth-211 584595012 L1-10202D-FSGS-211-SS Bismuth-211 584595013 L1-10202D-FSGS-211-SB Bismuth-211 584595018 L1-10202D-FSGS-216-SS Bismuth-211 584595019 L1-10202D-FSGS-216-SB Bismuth-214 584595003 L1-10202D-FSGS-202-SS Bismuth-214 584595005 L1-10202D-FSGS-204-SS Bismuth-214 584595007 L1-10202D-FSGS-206-SS Bismuth-214 584595010 L1-10202D-FSGS-209-SS Bismuth-214 584595011 L1-10202D-FSGS-210-SS Bismuth-214 584595014 L1-10202D-FSGS-212-SS Product: Gammaspec, Gamma, Solid (Requested List)

Analytical Method: DOE HASL 300, 4.5.2.3/Ga-01-R Analytical Procedure: GL-RAD-A-013 REV# 27 Analytical Batch: 2284624 Preparation Method: Dry Soil Prep Preparation Procedure: GL-RAD-A-021 REV# 24 Preparation Batch: 2284254 Page 59 of 60 SDG: 584595

The following samples were analyzed using the above methods and analytical procedure(s).

GEL Sample ID# Client Sample Identification 584595021 L1-10202D-FSGS-218-SS 1205129813 Method Blank (MB) 1205129814 584595021(L1-10202D-FSGS-218-SS) Sample Duplicate (DUP) 1205129815 Laboratory Control Sample (LCS)

The samples in this SDG were analyzed on a "dry weight" basis.

Data Summary:

All sample data provided in this report met the acceptance criteria specified in the analytical methods and procedures for initial calibration, continuing calibration, instrument controls and process controls where applicable, with the following exceptions.

Quality Control (QC) Information Duplication Criteria between QC Sample and Duplicate Sample The Sample and Duplicate did not meet the duplication criteria. All other identified nuclides met the duplication criteria.

Sample Analyte Value 1205129814 (L1-10202D-FSGS-218-SSDUP) Lead-212 RPD 63.5* (0.00%-20.00%)

Qualifier Information Qualifier Reason Analyte Sample Client Sample Results are considered a false positive UI Bismuth-211 1205129814 L1-10202D-FSGS-218-SS(584595021DUP) due to high counting uncertainty.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Page 60 of 60 SDG: 584595