ZION STATION RESTORATION PROJECT FINAL STATUS SURVEY RELEASE RECORD TURBINE BUILDING 560 FOOT ELEVATION EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 PREPARED BY / DATE: P. Giza 1/19/2019 Radiological Engineer REVIEWED BY / DATE: R. Massengill 1/19/2019 Radiological Engineer APPROVED BY / DATE: D. Wojtkowiak 1/19/2019 C/LT Manager
[2]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 TABLE OF CONTENTS
- 1. EXECUTIVE
SUMMARY
................................................................................................... 5
- 2. SURVEY UNIT DESCRIPTION ......................................................................................... 5
- 3. CLASSIFICATION BASIS .................................................................................................. 6
- 4. DATA QUALITY OBJECTIVES (DQO) ........................................................................... 6
- 5. SURVEY DESIGN ................................................................................................................ 8
- 6. SURVEY IMPLEMENTATION........................................................................................ 14
- 7. SURVEY RESULTS............................................................................................................ 16
- 8. QUALITY CONTROL ....................................................................................................... 17
- 9. INVESTIGATIONS AND RESULTS ............................................................................... 17
- 10. REMEDIATION AND RESULTS ..................................................................................... 17
- 11. CHANGES FROM THE SURVEY PLAN ....................................................................... 17
- 12. DATA QUALITY ASSESSMENT (DQA) ........................................................................ 18
- 13. ANOMALIES....................................................................................................................... 18
- 14. CONCLUSION .................................................................................................................... 18
- 15. REFERENCES .................................................................................................................... 18
- 16. ATTACHMENTS ................................................................................................................ 19 ATTACHMENT 1 - MAPS ................................................................................................. 20 ATTACHMENT 2 - SAMPLE DATA ............................................................................... 22 ATTACHMENT 3 - SIGN TEST ....................................................................................... 27 ATTACHMENT 4 - QC SAMPLE ASSESSMENT ......................................................... 31 ATTACHMENT 5 - GRAPHICAL PRESENTATIONS ................................................ 33
[3]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 LIST OF TABLES Table 1 - Dose Significant Radionuclides and Mixture............................................................................ 7 Table 2 - Base Case and Operational DCGLs for the Turbine Building Embedded Drain Pipe ............. 8 Table 3 - Surrogate Ratios ........................................................................................................................ 9 Table 4 - Surrogate Base Case and Operational DCGLs ........................................................................ 10 Table 5 - Typical FSS Instrument Detection Sensitivities...................................................................... 12 Table 6 - Synopsis of Survey Design ..................................................................................................... 13 Table 7 - Survey Data Collected ............................................................................................................. 15 Table 8 - Instrument and Detector .......................................................................................................... 15 Table 9 - Turbine Building 560 ft. Elevation Embedded Floor Drains - Statistical Summary.............. 17
[4]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105
- 1. EXECUTIVE
SUMMARY
This Final Status Survey (FSS) Release Record for Survey Unit #S3-06105BF, the embedded floor drain pipe located in the concrete floor of the Turbine Building 560 foot elevation, has been generated for the Zion Station Restoration Project (ZSRP). The release record was developed in accordance with ZionSolutions procedure ZS-LT-300-001-005, Final Status Survey Data Reporting (Reference 1) and satisfies the requirements of Section 5.11 of the Zion Station Restoration Project License Termination Plan (LTP) (Reference 2).
FSS Sample Plan S3-06105BF was developed in accordance with ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package Development (Reference 3) the ZSRP LTP, and guidance from NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (Reference 4).
FSS was conducted to demonstrate that the concentrations of residual radioactivity are equal to or below site-specific Derived Concentration Guideline Levels (DCGL) corresponding to the dose criterion in 10 CFR 20.1402. The embedded floor drain pipe located in the concrete floor of the Turbine Building 560 foot elevation, or Turbine Building Embedded Pipe was classified as MARSSIM Class 3.
The Turbine Building Embedded Pipe was surveyed with a Ludlum 2350-1 Data Logger paired with a 44-157 and a 44-159 gamma detector. Access to the pipe interior surfaces was achieved through pipe outlets in the two Equipment Sump Pits, the Turbine Building Floor Sump and the Fire Sump Pit. The total linear feet of embedded pipe is approximately 1,250 feet and pipe diameter ranged from an interior diameter (ID) of 4 to 10 inches. One hundred and thirty-three (133) measurements were acquired at one-foot intervals in sections of the pipe that were accessible. This resulted in an areal coverage of 11%, which provided sufficient measurements to allow for the 10% coverage requirement for a Class 3 survey unit.
Of the 133 measurements obtained in the Turbine Building embedded pipe, no measurement exceeded a SOF of 0.5 when compared against the Operational DCGL for embedded pipe in the Turbine Building (OpDCGLEP). The mean Sum-of-Fraction when compared against the Operational DCGL (OpSOF) was 0.0114 with a maximum OpSOF of 0.0278. When compared against the Base Case DCGL for the Turbine Building (BcDCGLEP), the mean BcSOF was 0.0005, which results in the dose calculated for this survey unit to be 0.0114 mrem/yr.
- 2. SURVEY UNIT DESCRIPTION The embedded drain piping in the Turbine Building consisted of 4-inch, 6-inch, 8-inch and 10-inch diameter pipe that is approximately 1,250 linear feet in length. The floor of the Turbine Building is at 560 foot elevation, with the drain piping embedded in the concrete approximately 2 feet deep.
[5]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105
- 3. CLASSIFICATION BASIS Survey Unit #S3-06105BF was classified in accordance with ZionSolutions procedure ZS-LT-300-001-002, Survey Unit Classification (Reference 5).
The Turbine Building was initially classified as a Class 2 structure by the Zion Station Historical Site Assessment (HSA) (Reference 6). LTP Section 5.5.2.1.2 changed the classification of the Turbine Building basement from Class 2 to Class 3. The LTP states The FSS units for the basements of the Turbine Building, the Crib House/Forebay, WWTF and the Circulating Water Discharge Tunnels are designated as Class 3 as defined in MARSSIM, section 2.2 in that the FSS units are expected to contain levels of residual activity at a small fraction of the DCGLs, based on site operating history and previous radiation surveys.
- 4. DATA QUALITY OBJECTIVES (DQO)
Final Status Survey planning and design hinges on coherence with the Data Quality Objective (DQO) process to ensure, through compliance with explicitly defined inputs and boundaries, that the primary objective of the survey is satisfied. The DQO process is described in the ZSRP LTP in accordance with MARSSIM. The appropriate design for a given survey will be developed using the DQO process as outlined in Appendix D of MARSSIM.
The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria.
Therefore, the survey unit would satisfy the primary objective of the FSS sample plan.
The primary objective of the FSS sample plan is to demonstrate that the level of residual radioactivity in Survey Unit #S3-06105BF did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
LTP Chapter 6, section 6.5.2 discusses the process used to derive the ROC for the decommissioning of ZNPS, including the elimination of insignificant dose contributors (IC) from the initial suite. Based upon the analysis of the mixture, it was determined that Co-60, Ni-63, Sr-90, Cs-134 and Cs-137 accounted for 99.5% of all dose in the non-activated contaminated concrete mixes.
[6]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 The residual radioactivity in embedded piping located below the 588 foot grade that will remain and be subjected to FSS is discussed in LTP Chapter 2, section 2.3.3.7 and TSD 14-016, Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State (Reference 7). The DCGLs for embedded piping are listed in LTP Chapter 5, sections 5.2.7 and 5.2.8.
Due to absence of significant source term in the Turbine Building, the suite of ROC and radionuclide mixture derived for the Auxiliary Building concrete was considered as a reasonable conservative mixture to apply to the Turbine Building embedded pipe for FSS planning and implementation. Table 1 reproduces the ROC from LTP Chapter 5, Table 5-2.
Table 1 - Dose Significant Radionuclides and Mixture Auxiliary Building Radionuclide % of Total Activity (normalized)(1)
Co-60 0.92%
Ni-63 23.71%
Sr-90 0.05%
Cs-134 0.01%
Cs-137 75.32%
(1) Based on maximum percent of total activity from Table 20 of TSD 14-019, normalized to one for the dose significant radionuclides.
A FSS is conducted on the interior surfaces of embedded piping to demonstrate that the concentrations of residual activity are equal to or below DCGLs corresponding to the dose criterion in 10CFR20.1402 (DCGLEP). DCGLEP were calculated for each of the remaining embedded pipe systems. The DCGLEP values for the Turbine Building embedded drain pipe system from LTP Chapter 6, section 6.13 are referred to as Base Case DCGLs.
At ZNPS, compliance is demonstrated through the summation of dose from four distinct source terms for the end-state (basements, soils, buried pipe and groundwater). Each radionuclide-specific Base Case DCGL is equivalent to the level of residual radioactivity (above background levels) that could, when considered independently, result in a Total Effective Dose Equivalent (TEDE) of 25 mrem per year to an Average Member of the Critical Group (AMCG). To ensure that the summation of dose from each source term is 25 mrem/year or less after all FSS is completed, the Base Case DCGLs are reduced based on an expected, or a priori, fraction of the 25 mrem/year dose limit from each source term. The reduced DCGLs, or Operational DCGLs can be related to the Base Case DCGLs as an expected fraction of dose based on an a priori assessment of what the expected dose should be based on the results of site characterization, process knowledge and the extent of planned remediation. The Operational
[7]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 DCGL is then used as the DCGL for the FSS design of the survey unit (calculation of surrogate DCGLs, investigations levels, etc.). Details of the Operational DCGLs derived for each dose component and the basis for the applied a priori dose fractions are provided in ZionSolutions TSD 17-004, Operational Derived Concentration Guideline Levels for Final Status Survey (Reference 8).
The Base Case and Operational DCGLs for the Turbine Building embedded drain pipe are listed in Tables 5-11 and 5-12 of the LTP and are reproduced in Table 2 below.
Table 2 - Base Case and Operational DCGLs for the Turbine Building Embedded Drain Pipe Base Case Operational Radionuclide Embedded Pipe DCGL Embedded Pipe DCGL 2
pCi/m
- pCi/m2 Co-60 6.31E+09 2.52E+08 Cs-134 1.43E+09 5.72E+07 Cs-137 1.89E+09 7.56E+07 Ni-63 1.96E+11 7.84E+09 Sr-90 6.94E+07 2.78E+06
- 5. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in procedure ZS-LT-300-001-001 Final Status Survey Package Development.
During FSS, concentrations for Hard-to-Detect (HTD) ROC Ni-63 and Sr-90 are inferred using a surrogate approach. Cs-137 is the principle surrogate radionuclide for Sr-90 and Co-60 is the principle surrogate radionuclide for Ni-63. The mean, maximum and 95% Upper Confidence Level (UCL) of the surrogate ratios for concrete core samples taken in the Auxiliary Building basement were calculated in ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms (Reference 9) and are presented in Table 3. The maximum ratios will be used in the surrogate calculations during this FSS. Equations 2 through 5 show the results of the calculations. The results of the surrogate calculations are listed in Table 4.
[8]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 Table 3 - Surrogate Ratios Auxiliary Building Ratios Mean Max 95%UCL Ni-63/Co-60 44.143 180.450 154.632 Sr-90/Cs-137 0.001 0.002 0.002 The equation for calculating a surrogate DCGL is as follows:
Equation 1 1
=
1 2 3
+ + +
2 3 Using the Base Case and Operational DCGLs presented in Table 2 and the maximum ratios from Table 3, the following surrogate calculations were performed:
Equation 2 (Cs-137 Surrogate Base Case DCGL) 1 (137) = = 1.7909 /2 1 0.002
+
1.8909(137) 6.9407(90)
Equation 3 (Cs-137 Surrogate Operational DCGL) 1 (137) = = 7.1707 /2 1 0.002
+
7.5607(137) 2.7806(90)
Equation 4 (Co-60 Surrogate Base Case DCGL) 1 (60) = = 9.2708 /2 1 180.45
+
6.3109(060) 1.9611(63)
Equation 5 (Co-60 Surrogate Operational DCGL) 1 (60) = = 3.7107 /2 1 180.45
+
2.5208(060) 7.8409(63)
[9]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 Table 4 - Surrogate Base Case and Operational DCGLs Base Case Operational Radionuclide Buried Pipe DCGL Buried Pipe DCGL 2
pCi/m pCi/m2 Co-60 9.27E+08 3.71E+07 Cs-134 1.43E+09 5.72E+07 Cs-137 1.79E+09 7.17E+07 Using the radionuclide mixture from Table 1, a gross gamma Operational DCGL of 1.75E+08 pCi/m2 was calculated. The Action Level used for the FSS of this survey unit was 50% of that value or 3.56E+07 pCi/m2.
The Turbine Building 560 foot elevation embedded drain system is Class 3 embedded pipe.
For the survey of pipe internal surfaces, areal coverage is achieved by the area of detection for each static measurement taken. Scanning, in the traditional context, is not applicable to the survey of pipe internal surfaces. For the survey of these pipes, the pipe detector was calibrated for the specific geometry of the 4-inch, 6-inch, 8-inch or 10-inch pipes. For a 4-inch ID pipe, each measurement has a calculated Field-of-View (FOV) of 1.08 ft2 (0.10 m2), for a 6-inch ID pipe, each measurement has a calculated Field-of-View (FOV) of 1.61 ft2 (0.15 m2), for an 8-inch ID pipe, each measurement has a calculated Field-of-View (FOV) of 2.05 ft2 (0.19 m2) and, for a 10-inch ID pipe, each measurement has a calculated Field-of-View (FOV) of 2.58 ft2 (0.24 m2)
The Turbine Building 560 foot elevation embedded drain system was comprised of approximately 1,250 linear feet of 4-inch, 6-inch, 8-inch or 10-inch ID piping, which equates to a surface area of approximately 237.5 m2. The LTP states that a FSS Class 3 survey unit shall have a minimum areal coverage of 10%. As some of the pipe was inaccessible due to blockages or pipe configuration, one measurement was taken every foot of all accessible pipe for a total of 133 distinct measurements over the entire accessible pathway of the piping system. For quality control purposes, a minimum of 5% of the measurements collected were to be duplicated. This required an additional 7 measurements to be collected throughout the length of the accessible surface of the piping system at locations selected at random.
Each static measurement represents the gamma activity in gross cpm for each specific measurement location. This gamma measurement value in cpm was then converted to dpm using an efficiency factor based on the calibration source. The total activity in dpm is then adjusted for the assumed total effective surface area commensurate with the pipe/penetration diameter, resulting in measurement results in units of dpm per m2. Unit conversion converted dpm to units of pCi. The measurement result, in units of pCi/m2, represents a commensurate and conservative gamma surface activity. The total gamma surface activity for each FSS
[10]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 measurement is converted to a gamma measurement result (in units of pCi/m2) for each gamma ROC based on the normalized gamma mixture from Table 1. Concentrations for HTD ROC are inferred using the surrogate approach in accordance with LTP Chapter 5. Cs-137 is the principle surrogate radionuclide for H-3 and Sr-90. Co-60 is the principle surrogate radionuclide for Ni-63. The maximum ratios from Table 3, which are reproduced from Table 5-15 of the LTP, are be used in the surrogate calculations.
The unity rule is applied when there is more than one ROC. The measurement results for each singular ROC present in the mixture are compared against their respective DCGL to derive a dose fraction. The summation of the dose fractions for each ROC produces a SOF for the measurement. When compared against the Base Case DCGL, the term is defined as BcSOF. When compared against the Operational DCGL, the term is defined as OpSOF.
To demonstrate that each survey unit satisfies the Operational DCGL, the ROC concentration for each measurement taken in the Turbine Building 560 ft. Embedded Floor Drain Pipe was divided by its applicable Operational DCGL (OpDCGLEP for embedded pipe) to derive a OpSOF for the ROC. The OpSOF for each ROC was then summed to determine the total OpSOF for all ROC that represents the measurement and was used as the summed value (Ws) for performing the Sign Test.
If the OpSOF for a random or judgmental measurement exceeded 0.5 in a Class 3 survey unit, then an investigation would be initiated in accordance with LTP Chapter 5, section 5.6.4.6 (Table 5-25). In a Class 3 FSS unit, the result of the investigation could prompt the reclassification of the survey unit (or a portion of the survey unit).
Embedded pipe survey units have a relatively small surface area leading to Operational DCGLs that are higher than the wall/floor Operational DCGLs. The reason for this fact is that the total internal surface area of the embedded pipe survey unit in a given basement is much less than the total wall/floor surface area of the basement containing them. To eliminate the potential for activity levels in embedded pipe that could lead to releases greater than surrounding walls and floors, the following remediation and grouting action levels were applied to measurements of surface activity in embedded pipe.
- If maximum activity exceeds the Base Case DCGLEP from Table 2 (SOF >1), then remediation was performed.
- If the maximum activity in an embedded pipe exceeded the surface Operational DCGLB from LTP Chapter 5, Table 5-4 (SOF>1) in the building that contains it, but was below the Base Case DCGLEP from Table 2, then the embedded pipe was remediated or grouted.
- If an embedded pipe was remediated and the maximum activity continues to exceed the surface Operational DCGLB from LTP Chapter 5, Table 5-4 (SOF>1), but is less than the Operational DCGLEP from Table 3, then the embedded pipe was grouted.
[11]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105
- If the maximum activity was below the surface Operational DCGLB from LTP Chapter 5, Table 5-4 (SOF>1), then grouting of the pipe was not required.
The instrumentation used for the FSS of the Turbine Building 560 foot elevation embedded drain system was the Ludlum Model 2350-1 and either the Model 44-157 detector or the Model 44-159 detector. The instrumentation sensitivities are provided in Chapter 5 of the LTP and are reproduced in Table 5.
In compliance with ZS-LT-01, Quality Assurance Project Plan (QAPP) for Characterization and Final Status Survey (Reference 10), replicate measurements were to be performed on 5%
of the static measurement locations.
Table 5 - Typical FSS Instrument Detection Sensitivities BKGD Typical Typical Count Instrument Static MDC Scan MDC Radiation count time BKGD Instrument Time
/Detector (dpm/100 cm2) (dpm/100 cm2)
(min.) (cpm) Efficiencyab (min.)
Ludlum 2350-1/
Gamma 1 6,300 0.212 1 1,750 N/A 44-157 Ludlum 2350-1/
Gamma 1 700 0.024 1 5,250 N/A 44-159 a) Typical calibration source used is Cs-137. The efficiency is determined by counting the source with the detector in a fixed position from the source (reproducible geometry). The t value is based on ISO-7503-1 and conditions noted for each detector.
b) The efficiency varies for the pipe detectors depending on the pipe diameter used. The efficiency used for the table is the average efficiency value for the pipe diameters. The detectors and diameters are: Model 44-159: 2-4 in. dia., Model 44-157: 4-8 in. dia., Model 44-162: 8-12 in. diameter.
[12]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 Table 6 - Synopsis of Survey Design FEATURE DESIGN CRITERIA BASIS 1,250 linear feet of 4, 6, 8 and 10 Survey Unit Area 237.5 m2 inch ID pipe Number of Static 133 10% areal coverage, Class 3 Measurements Measurement As needed to obtain sufficient 10% areal coverage, Class 3 Spacing measurements for 10% areal coverage
- Co 2.52E+08 pCi/m2
- Cs-134 - 5.72E+07 pCi/m2 Operational DCGLs for Turbine Building Basement Drain DCGLs
- Cs-137 - 7.56E+07 pCi/m2 Embedded Pipe,
- Ni 7.84E+09 pCi/m2 (LTP Chapter 5, Table 5-12)
- Sr 2.78E+06 pCi/m2 Gross Gamma DCGL adjusted for HTD HTD ROC Analysis LTP 5.7.1.9 based on the isotopic mixture Measurement
>0.5 Gross Gamma Operational DCGL (LTP Chapter 5, Table 5-25)
Investigation Level Scan Survey Area N/A LTP 5.7.1.9 Coverage Replicate measurements will be QC performed on 5% of the static QAPP measurement locations
[13]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105
- 6. SURVEY IMPLEMENTATION Survey instructions for this FSS were incorporated into and performed in accordance with FSS Sample Plan #S3-06105BF, which was developed in accordance with ZionSolutions procedure ZS-LT-300-001-001. The FSS unit was inspected and controlled in accordance with ZionSolutions procedure ZS-LT-300-001-003, Isolation and Control for Final Status Survey (Reference 11).
The approach used for the radiological survey of the interior surfaces of the Turbine Building 560 foot elevation embedded drain system involved the insertion of a 1 x 1 CsI or 2 x 2 NaI detector that was attached to the See Snake camera system and transported through the pipe to the maximum deployment length, or to a location of drain drop. A simple push-pull methodology was used, whereby the position of the detector in the piping system could be easily determined in a reproducible manner. Footage was tabulated on the See Snake, then measurements were obtained at 1 foot intervals while backing out of the pipe section.
A background value was also determined for the detector/instrument combination to be used prior to deployment. The background value was obtained at the location where the pre-use response check of the instrument was performed. The background value was primarily used to ensure that the detector had not become cross-contaminated by any previous use. Background was not subtracted from any measurement.
Daily prior to use and daily following use, each detector was subjected to an Operational Response Check in accordance with procedure ZS-LT-300-001-006, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors (Reference 12). The Daily Operational Response Check compared the background response and the response to check sources ranges established for normal background and detector source response to ensure that the detector was working properly.
Surveys of the Turbine Building 560 foot elevation embedded drain system were performed between April 18, 2016 and April 25, 2016. The floor drain system consisted of 26 floor drain openings, the floor drains from the Clean and Dirty Oil Storage tank rooms, and headers from floor drains on the upper elevations of the Turbine Building. The system terminated at one of the four Turbine Building basement sumps.
The See Snake and detector were inserted into the pipe from the sump openings. Because the entire length of the pipe was not available for survey, it was decided to take measurements at 1-foot intervals to obtain sufficient readings to meet the 10% coverage required for the Class 3 survey unit. Table 7 summarizes the data collected:
[14]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 Table 7 - Survey Data Collected
- of Length Pipe run Pipe ID measurements Comment surveyed taken U1 Equipment Drain Sump, 6 7 7 Pipe 1 U1 Equipment Drain Sump, 6 7 7 Pipe 2 U1 Equipment Drain Sump, 6 7 7 Pipe 3 TB Fire Sump, 13 QC 4 35 35 Pipe 6 Measurements Taken TB Floor Drain Sump, 6 28 28 Pipe 4 TB Floor Drain Sump, 4 7 7 Pipe 5 TB Fire Sump, 8 14 14 Pipe 7 TB Fire Sump, 10 8 8 Pipe 9 TB Fire Sump, 10 8 8 Pipe 10 TB Fire Sump, 8 12 12 Pipe 8 The instrument and detectors used for this survey are presented in Table 8. The instrument and detector were verified to be properly calibrated prior to use.
Table 8 - Instrument and Detector Instrument/Detector Calibration Due Serial #
Type Date Ludlum 2350-1 304718 10/29/16 Ludlum 44-157 PR327899 10/29/16 Ludlum 44-159 PR327897 10/29/16 Daily prior to use (Pre-Test) and daily upon completion of surveys (Post-Test), response checks were performed in accordance with procedure ZS-LT-300-001-006 for each detector and data logger pairing. In addition, all instruments and detectors were physically inspected for mechanical damage as part of the response check process. During the FSS, no instances were encountered where an instrument and/or detector failed a Pre or Post response check or were found to be physically damaged during the inspection.
[15]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105
- 7. SURVEY RESULTS After completion of the FSS measurements in the pipe, the sample plan was reviewed to confirm the completeness of the survey and the survey data was validated in accordance with procedure ZS-LT-300-001-004, Final Status Survey Data Assessment (Reference 13). Data processing includes converting measurement data into reporting units, validating instrument applicability and sensitivity, calculating relevant statistical quantities, and verification that all DQO have been met. In accordance with the procedure, a preliminary Data Assessment was prepared.
The primary gamma emitting ROC for the FSS of the Turbine Building 560 foot elevation embedded drain system survey unit are Co-60, Cs-134 and Cs-137. Ni-63 and Sr-90 are also ROC for the Turbine Building 560 foot elevation. Ni-63 is inferred from the measured concentration of Co-60, while Sr-90 is inferred from the measured concentration of Cs-137.
All measurements were less than 50% of the OpDCGL, meeting the requirement for a Class 3 area.
The mean of the OpSOF for all 133 samples was 0.0114.
The activity in this pipe must also compared to the OpDCGLB for the building that contains it.
The results of this comparison show that 2 of the 133 measurements were greater than 1 when compared to the OpDCGLB for the Turbine Building, with a maximum SOF of 1.17. The two pipes affected were Unit 1 Equipment Drain Sump, pipe #3, position 0 and Turbine Building Floor Drain Sump, pipe #5, position 2. Revision 2 of the LTP would require that both of these pipes be grouted in accordance with Chapter 5, section 5.5.5. However, this compliance survey was performed prior to the acceptance of the grouting commitments and since completion of the survey, the building was completely backfilled. Due to the low dose consequence, no further action is deemed necessary.
The results of the data assessment for the embedded floor drain pipe are provided in Attachment 2. A statistical summary of the data is presented in Table 9.
The data collected passed the Sign Test. The result of the Sign Test is provided in Attachment 3.
[16]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 Table 9 - Turbine Building 560 ft. Elevation Embedded Floor Drains - Statistical Summary Standard Base Case Mean Max Min Nuclide Deviation DCGLEP Radionuclide Mean SOF (BcDCGLEP)
(pCi/m2) (pCi/m2) (pCi/m2) (pCi/m2) (pCi/m2)
Co-60 9.69E+03 2.37E+04 5.25E+03 4.10E+03 5.98E+06 0.0000 Cs-134 1.07E+02 2.61E+02 5.79E+01 4.51E+01 1.35E+06 0.0000 Cs-137 7.96E+05 1.95E+06 4.32E+05 3.37E+05 1.79E+06 0.0004 Ni-63(1) 1.75E+06 4.27E+06 9.48E+05 7.39E+05 1.85E+08 0.0000 Sr-90(1) 1.59E+03 3.89E+03 8.63E+02 6.73E+02 6.58E+04 0.0000 (1) Concentrations for Ni-63 and Sr-90 are inferred Mean BcSOF 0.0005 Assigned Dose 0.0114
- 8. QUALITY CONTROL In compliance with ZS-LT-01, replicate measurements were performed on 5% of the survey locations chosen at random. Thirteen (13) replicate measurements were taken. Using the acceptance criteria specified ZS-LT-01, Quality Assurance Project Plan (QAPP) for Characterization and Final Status Survey, there was acceptable agreement between the replicate readings and the original readings. Refer to Attachment 4 for quality control analysis results.
- 9. INVESTIGATIONS AND RESULTS As all measurements in the accessible pipe interior surface area was below a SOF of 0.5, no investigations were required or performed.
- 10. REMEDIATION AND RESULTS No remediation was performed in this piping Survey Unit.
- 11. CHANGES FROM THE SURVEY PLAN Only 133 feet of the piping was accessible for survey, therefore readings were taken at 1-foot intervals in the pipe run to obtain enough measurements to meet the 10% coverage requirement for Class 3 survey units.
The survey instructions called for a 44-157 detector to be used for the survey. Due to the size limitation for a 4 pipe, the smaller 44-159 detector was used instead.
[17]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105
- 12. DATA QUALITY ASSESSMENT (DQA)
In accordance with procedure ZS-LT-300-001-004, the DQOs, sample design, and data were reviewed for completeness, accuracy, and consistency. Documentation was complete and legible. The FSS unit was properly classified as Class 3. All measurement results were individually reviewed and validated. The number of measurements was sufficient to meet the requirement of 10% areal coverage of accessible surfaces. The instrumentation used to perform the FSS were in calibration, capable of detecting the activity with an adequate MDC and successfully response checked prior to and following use. An adequate number of replicate measurements were taken and the results meet the acceptance criteria as specified in the QAPP.
The data for Gross Gamma Activity is represented graphically through a frequency plot and a quantile plot. All graphical representations are provided in Attachment 5.
- 13. ANOMALIES No anomalies were observed during the performance or analyses of the survey.
- 14. CONCLUSION One hundred and thirty-three (133) static measurements were taken in the Turbine Building 560 foot elevation embedded drain system, taken at 1 foot intervals. The total length of pipe was 1,250 feet, therefore the 10% areal survey coverage required for Class 3 survey units was met.
All of the measurements were below a SOF of 0.5, when compared to the OpDCGLEP. The average BcSOF for the survey unit is 0.0005. The requirements for a Class 3 survey unit have been met.
The Sign Test was passed, and the Null Hypothesis was rejected. A Retrospective Power Curve showed that adequate power was achieved.
The dose contribution from embedded pipe in Survey Unit #S3-06105BF, Turbine Building 560 ft. Embedded Drain Pipe, is 0.0114 mrem/yr TEDE, based on the average concentration of the ROC in samples used for non-parametric statistical sampling.
Survey Unit #S3-06105BF, Turbine Building 560 ft. Embedded Drain Pipe is acceptable for unrestricted release.
- 15. REFERENCES
- 1. ZionSolutions procedure ZS-LT-300-001-005, Final Status Survey Data Reporting
- 2. Zion Station Restoration Project License Termination Plan (LTP)
- 3. ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package Development
[18]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105
- 4. NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM)
- 5. ZionSolutions procedure ZS-LT-300-001-002, Survey Unit Classification
- 6. Zion Station Historical Site Assessment (HSA)
- 7. ZionSolutions TSD 14-016, Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State
- 8. ZionSolutions TSD 17-004, Operational Derived Concentration Guideline Levels for Final Status Survey
- 9. ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms
- 10. ZionSolutions procedure ZS-LT-01, Quality Assurance Project Plan (QAPP) for Characterization and Final Status Survey
- 11. ZionSolutions procedure ZS-LT-300-001-003, Isolation and Control for Final Status Survey
- 12. ZionSolutions procedure ZS-LT-300-001-006, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors
- 13. ZionSolutions procedure ZS-LT-300-001-004, Final Status Survey Data Assessment
- 16. ATTACHMENTS
- 1. Attachment 1 - Maps
- 2. Attachment 2 - Sample Data
- 3. Attachment 3 - Sign Test
- 4. Attachment 4 - QC Sample Assessment
- 5. Attachment 5 - Graphical Presentations
[19]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 ATTACHMENT 1 - MAPS
[20]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 FIGURE 1
[21]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 ATTACHMENT 2 - SAMPLE DATA
[22]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 TURBINE BUILDING 560 FOOT ELEVATION EMBEDDED FLOOR DRAIN PIPE MEASUREMENTS GROSS PIPE Co-60 Cs-134 Cs-137 Ni-63 Sr-90 OpSOF GAMMA U1 Eq Drain Sump Pipe 1 Position 0 6.49E+05 7.80E+03 8.59E+01 6.41E+05 1.41E+06 1.28E+03 0.0091542 U1 Eq Drain Sump Pipe 1 Position 1 6.73E+05 8.09E+03 8.91E+01 6.65E+05 1.46E+06 1.33E+03 0.0094927 U1 Eq Drain Sump Pipe 1 Position 2 6.54E+05 7.86E+03 8.66E+01 6.46E+05 1.42E+06 1.29E+03 0.0092248 U1 Eq Drain Sump Pipe 1 Position 3 6.69E+05 8.04E+03 8.86E+01 6.61E+05 1.45E+06 1.32E+03 0.0094363 U1 Eq Drain Sump Pipe 1 Position 4 7.15E+05 8.60E+03 9.47E+01 7.06E+05 1.55E+06 1.41E+03 0.0100852 U1 Eq Drain Sump Pipe 1 Position 5 7.00E+05 8.42E+03 9.27E+01 6.91E+05 1.52E+06 1.38E+03 0.0098736 U1 Eq Drain Sump Pipe 1 Position 6 6.96E+05 8.37E+03 9.22E+01 6.88E+05 1.51E+06 1.38E+03 0.0098172 U1 Eq Drain Sump Pipe 2 Position 0 7.68E+05 9.23E+03 1.02E+02 7.59E+05 1.67E+06 1.52E+03 0.0108327 U1 Eq Drain Sump Pipe 2 Position 1 7.46E+05 8.97E+03 9.88E+01 7.37E+05 1.62E+06 1.47E+03 0.0105224 U1 Eq Drain Sump Pipe 2 Position 2 7.45E+05 8.96E+03 9.87E+01 7.36E+05 1.62E+06 1.47E+03 0.0105083 U1 Eq Drain Sump Pipe 2 Position 3 7.75E+05 9.32E+03 1.03E+02 7.66E+05 1.68E+06 1.53E+03 0.0109315 U1 Eq Drain Sump Pipe 2 Position 4 7.70E+05 9.26E+03 1.02E+02 7.61E+05 1.67E+06 1.52E+03 0.0108609 U1 Eq Drain Sump Pipe 2 Position 5 7.79E+05 9.37E+03 1.03E+02 7.70E+05 1.69E+06 1.54E+03 0.0109879 U1 Eq Drain Sump Pipe 2 Position 6 7.84E+05 9.43E+03 1.04E+02 7.74E+05 1.70E+06 1.55E+03 0.0110584 U1 Eq Drain Sump Pipe 3 Position 0 1.97E+06 2.37E+04 2.61E+02 1.95E+06 4.27E+06 3.89E+03 0.0277871 U1 Eq Drain Sump Pipe 3 Position 0 1.01E+06 1.21E+04 1.34E+02 9.98E+05 2.19E+06 2.00E+03 0.0142462 U1 Eq Drain Sump Pipe 3 Position 1 6.70E+05 8.06E+03 8.87E+01 6.62E+05 1.45E+06 1.32E+03 0.0094504 U1 Eq Drain Sump Pipe 3 Position 2 6.41E+05 7.71E+03 8.49E+01 6.33E+05 1.39E+06 1.27E+03 0.0090414 U1 Eq Drain Sump Pipe 3 Position 3 6.41E+05 7.71E+03 8.49E+01 6.33E+05 1.39E+06 1.27E+03 0.0090414 U1 Eq Drain Sump Pipe 3 Position 4 6.52E+05 7.84E+03 8.63E+01 6.44E+05 1.41E+06 1.29E+03 0.0091965 U1 Eq Drain Sump Pipe 3 Position 5 6.46E+05 7.77E+03 8.55E+01 6.38E+05 1.40E+06 1.28E+03 0.0091119 TB Fire Sump Pipe 6, Position 0 1.15E+06 1.38E+04 1.52E+02 1.14E+06 2.50E+06 2.27E+03 0.0162209 TB Fire Sump Pipe 6, Position 1 1.07E+06 1.29E+04 1.42E+02 1.06E+06 2.32E+06 2.11E+03 0.0150925 TB Fire Sump Pipe 6, Position 2 1.11E+06 1.33E+04 1.47E+02 1.10E+06 2.41E+06 2.19E+03 0.0156567 TB Fire Sump Pipe 6, Position 3 1.09E+06 1.31E+04 1.44E+02 1.08E+06 2.37E+06 2.15E+03 0.0153746 TB Fire Sump Pipe 6, Position 4 1.18E+06 1.42E+04 1.56E+02 1.17E+06 2.56E+06 2.33E+03 0.016644 TB Fire Sump Pipe 6, Position 5 1.11E+06 1.33E+04 1.47E+02 1.10E+06 2.41E+06 2.19E+03 0.0156567 TB Fire Sump Pipe 6, Position 6 1.09E+06 1.31E+04 1.44E+02 1.08E+06 2.37E+06 2.15E+03 0.0153746 TB Fire Sump Pipe 6, Position 7 1.13E+06 1.36E+04 1.50E+02 1.12E+06 2.45E+06 2.23E+03 0.0159388 TB Fire Sump Pipe 6, Position 8 1.06E+06 1.27E+04 1.40E+02 1.05E+06 2.30E+06 2.09E+03 0.0149514 TB Fire Sump Pipe 6, Position 9 9.22E+05 1.11E+04 1.22E+02 9.11E+05 2.00E+06 1.82E+03 0.0130049 TB Fire Sump Pipe 6, Position 10 1.10E+06 1.32E+04 1.46E+02 1.09E+06 2.39E+06 2.17E+03 0.0155156 TB Fire Sump Pipe 6, Position 11 1.13E+06 1.36E+04 1.50E+02 1.12E+06 2.45E+06 2.23E+03 0.0159388
[23]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 GROSS PIPE Co-60 Cs-134 Cs-137 Ni-63 Sr-90 OpSOF GAMMA TB Fire Sump Pipe 6, Position 12 1.09E+06 1.31E+04 1.44E+02 1.08E+06 2.37E+06 2.15E+03 0.0153746 TB Fire Sump Pipe 6, Position 13 1.06E+06 1.27E+04 1.40E+02 1.05E+06 2.30E+06 2.09E+03 0.0149514 TB Fire Sump Pipe 6, Position 14 1.19E+06 1.43E+04 1.58E+02 1.18E+06 2.58E+06 2.35E+03 0.0167851 TB Fire Sump Pipe 6, Position 15 1.20E+06 1.44E+04 1.59E+02 1.19E+06 2.60E+06 2.37E+03 0.0169261 TB Fire Sump Pipe 6, Position 16 1.27E+06 1.53E+04 1.68E+02 1.25E+06 2.76E+06 2.51E+03 0.0179135 TB Fire Sump Pipe 6, Position 17 1.21E+06 1.45E+04 1.60E+02 1.20E+06 2.63E+06 2.39E+03 0.0170672 TB Fire Sump Pipe 6, Position 18 1.16E+06 1.39E+04 1.54E+02 1.15E+06 2.52E+06 2.29E+03 0.0163619 TB Fire Sump Pipe 6, Position 19 1.19E+06 1.43E+04 1.58E+02 1.18E+06 2.58E+06 2.35E+03 0.0167851 TB Fire Sump Pipe 6, Position 20 9.91E+05 1.19E+04 1.31E+02 9.79E+05 2.15E+06 1.96E+03 0.0139782 TB Fire Sump Pipe 6, Position 21 1.17E+06 1.41E+04 1.55E+02 1.16E+06 2.54E+06 2.31E+03 0.016503 TB Fire Sump Pipe 6, Position 22 1.19E+06 1.43E+04 1.58E+02 1.18E+06 2.58E+06 2.35E+03 0.0167851 TB Fire Sump Pipe 6, Position 23 1.25E+06 1.50E+04 1.66E+02 1.23E+06 2.71E+06 2.47E+03 0.0176314 TB Fire Sump Pipe 6, Position 24 1.22E+06 1.47E+04 1.62E+02 1.21E+06 2.65E+06 2.41E+03 0.0172083 TB Fire Sump Pipe 6, Position 25 1.27E+06 1.53E+04 1.68E+02 1.25E+06 2.76E+06 2.51E+03 0.0179135 TB Fire Sump Pipe 6, Position 26 1.21E+06 1.45E+04 1.60E+02 1.20E+06 2.63E+06 2.39E+03 0.0170672 TB Fire Sump Pipe 6, Position 27 1.28E+06 1.54E+04 1.70E+02 1.26E+06 2.78E+06 2.53E+03 0.0180546 TB Fire Sump Pipe 6, Position 28 1.42E+06 1.71E+04 1.88E+02 1.40E+06 3.08E+06 2.81E+03 0.0200293 TB Fire Sump Pipe 6, Position 29 1.26E+06 1.52E+04 1.67E+02 1.24E+06 2.73E+06 2.49E+03 0.0177725 TB Fire Sump Pipe 6, Position 30 1.23E+06 1.48E+04 1.63E+02 1.22E+06 2.67E+06 2.43E+03 0.0173493 TB Fire Sump Pipe 6, Position 31 1.30E+06 1.56E+04 1.72E+02 1.28E+06 2.82E+06 2.57E+03 0.0183367 TB Fire Sump Pipe 6, Position 32 1.11E+06 1.33E+04 1.47E+02 1.10E+06 2.41E+06 2.19E+03 0.0156567 TB Fire Sump Pipe 6, Position 33 1.44E+06 1.73E+04 1.91E+02 1.42E+06 3.12E+06 2.84E+03 0.0203114 TB Fire Sump Pipe 6, Position 34 1.38E+06 1.66E+04 1.83E+02 1.36E+06 2.99E+06 2.73E+03 0.0194651 TB FD Sump Pipe 4 Position 0 6.22E+05 7.48E+03 8.24E+01 6.14E+05 1.35E+06 1.23E+03 0.0087734 TB FD Sump Pipe 4 Position 1 6.15E+05 7.39E+03 8.14E+01 6.08E+05 1.33E+06 1.22E+03 0.0086747 TB FD Sump Pipe 4 Position 2 6.02E+05 7.24E+03 7.97E+01 5.95E+05 1.31E+06 1.19E+03 0.0084913 TB FD Sump Pipe 4 Position 3 6.05E+05 7.27E+03 8.01E+01 5.98E+05 1.31E+06 1.20E+03 0.0085336 TB FD Sump Pipe 4 Position 4 6.26E+05 7.53E+03 8.29E+01 6.18E+05 1.36E+06 1.24E+03 0.0088298 TB FD Sump Pipe 4 Position 5 6.25E+05 7.52E+03 8.28E+01 6.17E+05 1.36E+06 1.23E+03 0.0088157 TB FD Sump Pipe 4 Position 6 6.22E+05 7.48E+03 8.24E+01 6.14E+05 1.35E+06 1.23E+03 0.0087734 TB FD Sump Pipe 4 Position 7 6.28E+05 7.55E+03 8.32E+01 6.20E+05 1.36E+06 1.24E+03 0.008858 TB FD Sump Pipe 4 Position 8 6.03E+05 7.25E+03 7.99E+01 5.96E+05 1.31E+06 1.19E+03 0.0085054 TB FD Sump Pipe 4 Position 9 5.85E+05 7.03E+03 7.75E+01 5.78E+05 1.27E+06 1.16E+03 0.0082515 TB FD Sump Pipe 4 Position 10 6.10E+05 7.33E+03 8.08E+01 6.03E+05 1.32E+06 1.21E+03 0.0086041
[24]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 GROSS PIPE Co-60 Cs-134 Cs-137 Ni-63 Sr-90 OpSOF GAMMA TB FD Sump Pipe 4 Position 11 6.43E+05 7.73E+03 8.51E+01 6.35E+05 1.40E+06 1.27E+03 0.0090696 TB FD Sump Pipe 4 Position 12 6.18E+05 7.43E+03 8.18E+01 6.10E+05 1.34E+06 1.22E+03 0.008717 TB FD Sump Pipe 4 Position 13 6.01E+05 7.23E+03 7.96E+01 5.94E+05 1.30E+06 1.19E+03 0.0084772 TB FD Sump Pipe 4 Position 14 6.11E+05 7.35E+03 8.09E+01 6.04E+05 1.33E+06 1.21E+03 0.0086182 TB FD Sump Pipe 4 Position 15 5.91E+05 7.11E+03 7.83E+01 5.84E+05 1.28E+06 1.17E+03 0.0083361 TB Fire Sump Pipe 6, Position 15 1.20E+06 1.44E+04 1.59E+02 1.19E+06 2.60E+06 2.37E+03 0.0169261 TB FD Sump Pipe 4 Position 16 6.43E+05 7.73E+03 8.51E+01 6.35E+05 1.40E+06 1.27E+03 0.0090696 TB FD Sump Pipe 4 Position 17 5.95E+05 7.15E+03 7.88E+01 5.88E+05 1.29E+06 1.18E+03 0.0083925 TB FD Sump Pipe 4 Position 18 5.65E+05 6.79E+03 7.48E+01 5.58E+05 1.23E+06 1.12E+03 0.0079694 TB FD Sump Pipe 4 Position 19 6.02E+05 7.24E+03 7.97E+01 5.95E+05 1.31E+06 1.19E+03 0.0084913 TB FD Sump Pipe 4 Position 20 6.21E+05 7.47E+03 8.22E+01 6.13E+05 1.35E+06 1.23E+03 0.0087593 TB FD Sump Pipe 4 Position 21 6.21E+05 7.47E+03 8.22E+01 6.13E+05 1.35E+06 1.23E+03 0.0087593 TB FD Sump Pipe 4 Position 22 5.97E+05 7.18E+03 7.91E+01 5.90E+05 1.30E+06 1.18E+03 0.0084208 TB FD Sump Pipe 4 Position 23 6.14E+05 7.38E+03 8.13E+01 6.07E+05 1.33E+06 1.21E+03 0.0086605 TB FD Sump Pipe 4 Position 24 5.92E+05 7.12E+03 7.84E+01 5.85E+05 1.28E+06 1.17E+03 0.0083502 TB FD Sump Pipe 4 Position 25 6.05E+05 7.27E+03 8.01E+01 5.98E+05 1.31E+06 1.20E+03 0.0085336 TB FD Sump Pipe 4 Position 26 6.07E+05 7.30E+03 8.04E+01 6.00E+05 1.32E+06 1.20E+03 0.0085618 TB FD Sump Pipe 4 Position 27 6.18E+05 7.43E+03 8.18E+01 6.10E+05 1.34E+06 1.22E+03 0.008717 TB FD Sump Pipe 5 Position 0 1.61E+06 1.94E+04 2.13E+02 1.59E+06 3.49E+06 3.18E+03 0.0227092 TB FD Sump Pipe 5 Position 1 1.64E+06 1.97E+04 2.17E+02 1.62E+06 3.56E+06 3.24E+03 0.0231324 TB FD Sump Pipe 5 Position 2 1.79E+06 2.15E+04 2.37E+02 1.77E+06 3.88E+06 3.54E+03 0.0252482 TB FD Sump Pipe 5 Position 3 1.42E+06 1.71E+04 1.88E+02 1.40E+06 3.08E+06 2.81E+03 0.0200293 TB FD Sump Pipe 5 Position 4 1.38E+06 1.66E+04 1.83E+02 1.36E+06 2.99E+06 2.73E+03 0.0194651 TB FD Sump Pipe 5 Position 5 1.46E+06 1.76E+04 1.93E+02 1.44E+06 3.17E+06 2.88E+03 0.0205935 TB FD Sump Pipe 5 Position 6 1.38E+06 1.66E+04 1.83E+02 1.36E+06 2.99E+06 2.73E+03 0.0194651 TB Fire Sump Pipe 7, Position 0 5.95E+05 7.15E+03 7.88E+01 5.88E+05 1.29E+06 1.18E+03 0.0083925 TB Fire Sump Pipe 7, Position 1 5.71E+05 6.87E+03 7.56E+01 5.64E+05 1.24E+06 1.13E+03 0.008054 TB Fire Sump Pipe 7, Position 2 5.75E+05 6.91E+03 7.61E+01 5.68E+05 1.25E+06 1.14E+03 0.0081104 TB Fire Sump Pipe 7, Position 3 5.68E+05 6.83E+03 7.52E+01 5.61E+05 1.23E+06 1.12E+03 0.0080117 TB Fire Sump Pipe 7, Position 4 5.93E+05 7.13E+03 7.85E+01 5.86E+05 1.29E+06 1.17E+03 0.0083643 TB Fire Sump Pipe 7, Position 5 5.77E+05 6.94E+03 7.64E+01 5.70E+05 1.25E+06 1.14E+03 0.0081387 TB Fire Sump Pipe 7, Position 6 5.35E+05 6.43E+03 7.08E+01 5.28E+05 1.16E+06 1.06E+03 0.0075462 TB Fire Sump Pipe 7, Position 7 5.47E+05 6.58E+03 7.24E+01 5.40E+05 1.19E+06 1.08E+03 0.0077155 TB Fire Sump Pipe 7, Position 8 5.26E+05 6.32E+03 6.97E+01 5.20E+05 1.14E+06 1.04E+03 0.0074193
[25]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 GROSS PIPE Co-60 Cs-134 Cs-137 Ni-63 Sr-90 OpSOF GAMMA TB Fire Sump Pipe 7, Position 9 5.24E+05 6.30E+03 6.94E+01 5.18E+05 1.14E+06 1.04E+03 0.0073911 TB Fire Sump Pipe 7, Position 10 5.22E+05 6.28E+03 6.91E+01 5.16E+05 1.13E+06 1.03E+03 0.0073629 TB Fire Sump Pipe 7, Position 11 5.97E+05 7.18E+03 7.91E+01 5.90E+05 1.30E+06 1.18E+03 0.0084208 TB Fire Sump Pipe 7, Position 12 5.95E+05 7.15E+03 7.88E+01 5.88E+05 1.29E+06 1.18E+03 0.0083925 TB Fire Sump Pipe 7, Position 13 5.59E+05 6.72E+03 7.40E+01 5.52E+05 1.21E+06 1.10E+03 0.0078848 TB Fire Sump Pipe 9, Position 0 4.60E+05 5.53E+03 6.09E+01 4.54E+05 9.98E+05 9.09E+02 0.0064884 TB Fire Sump Pipe 9, Position 1 4.52E+05 5.43E+03 5.99E+01 4.47E+05 9.81E+05 8.93E+02 0.0063755 TB Fire Sump Pipe 9, Position 2 4.65E+05 5.59E+03 6.16E+01 4.59E+05 1.01E+06 9.19E+02 0.0065589 TB Fire Sump Pipe 9, Position 3 4.57E+05 5.50E+03 6.05E+01 4.51E+05 9.92E+05 9.03E+02 0.006446 TB Fire Sump Pipe 9, Position 4 4.51E+05 5.42E+03 5.97E+01 4.46E+05 9.79E+05 8.91E+02 0.0063614 TB Fire Sump Pipe 9, Position 5 4.57E+05 5.50E+03 6.05E+01 4.51E+05 9.92E+05 9.03E+02 0.006446 TB Fire Sump Pipe 9, Position 6 4.59E+05 5.52E+03 6.08E+01 4.53E+05 9.96E+05 9.07E+02 0.0064743 TB Fire Sump Pipe 9, Position 7 4.47E+05 5.37E+03 5.92E+01 4.42E+05 9.70E+05 8.83E+02 0.006305 TB Fire Sump Pipe 10, Position 0 4.57E+05 5.50E+03 6.05E+01 4.51E+05 9.92E+05 9.03E+02 0.006446 TB Fire Sump Pipe 10, Position 1 4.60E+05 5.53E+03 6.09E+01 4.54E+05 9.98E+05 9.09E+02 0.0064884 TB Fire Sump Pipe 10, Position 2 4.50E+05 5.41E+03 5.96E+01 4.45E+05 9.76E+05 8.89E+02 0.0063473 TB Fire Sump Pipe 10, Position 3 4.45E+05 5.35E+03 5.89E+01 4.40E+05 9.66E+05 8.79E+02 0.0062768 TB Fire Sump Pipe 10, Position 4 4.47E+05 5.37E+03 5.92E+01 4.42E+05 9.70E+05 8.83E+02 0.006305 TB Fire Sump Pipe 10, Position 5 4.56E+05 5.48E+03 6.04E+01 4.50E+05 9.89E+05 9.01E+02 0.0064319 TB Fire Sump Pipe 10, Position 6 4.67E+05 5.62E+03 6.18E+01 4.61E+05 1.01E+06 9.23E+02 0.0065871 TB Fire Sump Pipe 10, Position 7 4.37E+05 5.25E+03 5.79E+01 4.32E+05 9.48E+05 8.63E+02 0.0061639 TB Fire Sump Pipe 8, Position 0 5.06E+05 6.08E+03 6.70E+01 5.00E+05 1.10E+06 1.00E+03 0.0071372 TB Fire Sump Pipe 8, Position 1 5.10E+05 6.13E+03 6.75E+01 5.04E+05 1.11E+06 1.01E+03 0.0071936 TB Fire Sump Pipe 8, Position 2 5.14E+05 6.18E+03 6.81E+01 5.08E+05 1.12E+06 1.02E+03 0.00725 TB Fire Sump Pipe 8, Position 3 5.27E+05 6.34E+03 6.98E+01 5.21E+05 1.14E+06 1.04E+03 0.0074334 TB Fire Sump Pipe 8, Position 4 5.32E+05 6.40E+03 7.04E+01 5.26E+05 1.15E+06 1.05E+03 0.0075039 TB Fire Sump Pipe 8, Position 5 5.62E+05 6.76E+03 7.44E+01 5.55E+05 1.22E+06 1.11E+03 0.0079271 TB Fire Sump Pipe 8, Position 6 5.66E+05 6.81E+03 7.50E+01 5.59E+05 1.23E+06 1.12E+03 0.0079835 TB Fire Sump Pipe 8, Position 7 5.93E+05 7.13E+03 7.85E+01 5.86E+05 1.29E+06 1.17E+03 0.0083643 TB Fire Sump Pipe 8, Position 8 5.81E+05 6.99E+03 7.69E+01 5.74E+05 1.26E+06 1.15E+03 0.0081951 TB Fire Sump Pipe 8, Position 9 5.99E+05 7.20E+03 7.93E+01 5.92E+05 1.30E+06 1.18E+03 0.008449 TB Fire Sump Pipe 8, Position 10 6.20E+05 7.45E+03 8.21E+01 6.12E+05 1.35E+06 1.22E+03 0.0087452 TB Fire Sump Pipe 8, Position 11 6.00E+05 7.21E+03 7.95E+01 5.93E+05 1.30E+06 1.19E+03 0.0084631
[26]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 ATTACHMENT 3 - SIGN TEST
[27]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 Sign Test Turbine Building 560 Foot Elevation Embedded Floor Drain Pipe Survey Area 06100 Description Turbine Building Survey Unit S3-06105AF Description 560 ft. Embedded Floor Pipe Classification 31 Type I Error 0.05 # of Measurements 133 SOF SOF
- 1-Ws Sign # 1-Ws Sign (Ws) (Ws) 0 0.0092 0.9908 +1 63 0.0088 0.9912 +1 1 0.0095 0.9905 +1 64 0.0089 0.9911 +1 2 0.0092 0.9908 +1 65 0.0085 0.9915 +1 3 0.0094 0.9906 +1 66 0.0083 0.9917 +1 4 0.0101 0.9899 +1 67 0.0086 0.9914 +1 5 0.0099 0.9901 +1 68 0.0091 0.9909 +1 6 0.0098 0.9902 +1 69 0.0087 0.9913 +1 7 0.0108 0.9892 +1 70 0.0085 0.9915 +1 8 0.0105 0.9895 +1 71 0.0086 0.9914 +1 9 0.0105 0.9895 +1 72 0.0083 0.9917 +1 10 0.0109 0.9891 +1 73 0.0091 0.9909 +1 11 0.0109 0.9891 +1 74 0.0084 0.9916 +1 12 0.0110 0.9890 +1 75 0.0080 0.9920 +1 13 0.0111 0.9889 +1 76 0.0085 0.9915 +1 14 0.0278 0.9722 +1 77 0.0088 0.9912 +1 15 0.0142 0.9858 +1 78 0.0088 0.9912 +1 16 0.0095 0.9905 +1 79 0.0084 0.9916 +1 17 0.0090 0.9910 +1 80 0.0087 0.9913 +1 18 0.0090 0.9910 +1 81 0.0084 0.9916 +1 19 0.0092 0.9908 +1 82 0.0085 0.9915 +1 20 0.0091 0.9909 +1 83 0.0086 0.9914 +1 21 0.0162 0.9838 +1 84 0.0087 0.9913 +1 22 0.0151 0.9849 +1 85 0.0227 0.9773 +1 23 0.0157 0.9843 +1 86 0.0231 0.9769 +1 24 0.0154 0.9846 +1 87 0.0252 0.9748 +1 25 0.0166 0.9834 +1 88 0.0200 0.9800 +1 26 0.0157 0.9843 +1 89 0.0195 0.9805 +1 27 0.0154 0.9846 +1 90 0.0206 0.9794 +1 28 0.0092 0.9908 +1 91 0.0195 0.9805 +1
[28]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 Sign Test (continued)
SOF SOF
- 1-Ws Sign # 1-Ws Sign (Ws) (Ws) 29 0.0159 0.9841 +1 92 0.0084 0.9916 +1 30 0.0150 0.9850 +1 93 0.0081 0.9919 +1 31 0.0130 0.9870 +1 94 0.0081 0.9919 +1 32 0.0155 0.9845 +1 95 0.0080 0.9920 +1 33 0.0159 0.9841 +1 96 0.0084 0.9916 +1 34 0.0154 0.9846 +1 97 0.0081 0.9919 +1 35 0.0150 0.9850 +1 98 0.0075 0.9925 +1 36 0.0168 0.9832 +1 99 0.0077 0.9923 +1 37 0.0169 0.9831 +1 100 0.0074 0.9926 +1 38 0.0179 0.9821 +1 101 0.0074 0.9926 +1 39 0.0171 0.9829 +1 102 0.0074 0.9926 +1 40 0.0164 0.9836 +1 103 0.0084 0.9916 +1 41 0.0168 0.9832 +1 104 0.0084 0.9916 +1 42 0.0140 0.9860 +1 105 0.0079 0.9921 +1 43 0.0165 0.9835 +1 106 0.0065 0.9935 +1 44 0.0168 0.9832 +1 107 0.0064 0.9936 +1 45 0.0176 0.9824 +1 108 0.0066 0.9934 +1 46 0.0172 0.9828 +1 109 0.0064 0.9936 +1 47 0.0179 0.9821 +1 110 0.0064 0.9936 +1 48 0.0171 0.9829 +1 111 0.0064 0.9936 +1 49 0.0181 0.9819 +1 112 0.0065 0.9935 +1 50 0.0200 0.9800 +1 113 0.0063 0.9937 +1 51 0.0178 0.9822 +1 114 0.0064 0.9936 +1 52 0.0173 0.9827 +1 115 0.0065 0.9935 +1 53 0.0183 0.9817 +1 116 0.0063 0.9937 +1 54 0.0157 0.9843 +1 117 0.0063 0.9937 +1 55 0.0203 0.9797 +1 118 0.0063 0.9937 +1 56 0.0195 0.9805 +1 119 0.0064 0.9936 +1 57 0.0088 0.9912 +1 120 0.0066 0.9934 +1 58 0.0087 0.9913 +1 121 0.0062 0.9938 +1 59 0.0085 0.9915 +1 122 0.0071 0.9929 +1 60 0.0085 0.9915 +1 123 0.0072 0.9928 +1 61 0.0088 0.9912 +1 124 0.0073 0.9927 +1 62 0.0088 0.9912 +1 125 0.0074 0.9926 +1
[29]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 Sign Test (continued)
SOF
- 1-Ws Sign (Ws) 126 0.0075 0.9925 +1 127 0.0079 0.9921 +1 128 0.0080 0.9920 +1 129 0.0084 0.9916 +1 130 0.0082 0.9918 +1 131 0.0084 0.9916 +1 132 0.0087 0.9913 +1 133 0.0085 0.9915 +1 Number of Positive Differences (S+) = 325 Critical Value = 76 Survey Unit Meets the Acceptance Criteria
[30]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 ATTACHMENT 4 - QC SAMPLE ASSESSMENT
[31]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 Turbine Building 560 ft. Embedded Drain Pipe - QC Agreement Reading QC Reading Location +20% -20% QC Pass (pCi/m2) (pCi/m2)
TB Fire Sump Pipe 6, 1.15E+06 1.14E+06 1.38E+06 9.20E+05 Yes Position 0 TB Fire Sump Pipe 6, 1.07E+06 1.22E+06 1.28E+06 8.56E+05 Yes Position 1 TB Fire Sump Pipe 6, 1.11E+06 1.04E+06 1.33E+06 8.88E+05 Yes Position 2 TB Fire Sump Pipe 6, 1.09E+06 1.18E+06 1.31E+06 8.72E+05 Yes Position 3 TB Fire Sump Pipe 6, 1.18E+06 1.13E+06 1.42E+06 9.44E+05 Yes Position 4 TB Fire Sump Pipe 6, 1.11E+06 1.14E+06 1.33E+06 8.88E+05 Yes Position 5 TB Fire Sump Pipe 6, 1.09E+06 1.15E+06 1.31E+06 8.72E+05 Yes Position 6 TB Fire Sump Pipe 6, 1.13E+06 1.15E+06 1.36E+06 9.04E+05 Yes Position 7 TB Fire Sump Pipe 6, 1.06E+06 1.13E+06 1.27E+06 8.48E+05 Yes Position 8 TB Fire Sump Pipe 6, 9.22E+05 1.07E+06 1.11E+06 7.38E+05 Yes Position 9 TB Fire Sump Pipe 6, 1.10E+06 1.08E+06 1.32E+06 8.80E+05 Yes Position 10 TB Fire Sump Pipe 6, 1.13E+06 9.01E+05 1.36E+06 9.04E+05 No Position 11 TB Fire Sump Pipe 6, 1.09E+06 1.09E+06 1.31E+06 8.72E+05 Yes Position 12 TB Fire Sump Pipe 6, 1.15E+06 1.11E+06 1.38E+06 9.20E+05 Yes Position 0 One measurement out of the 13 QC measurements taken did not fall within the range of
+20% of the original measurement. The detector successfully passed the required post-use source and quality checks. Twelve (12) of the 13 QC measurements taken with the same detector fell within the range of +20% of the original measurement and, the measurement that did fall outside low was essentially just below the lower range limit
(-20.3%). No further action was deemed necessary.
[32]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 ATTACHMENT 5 - GRAPHICAL PRESENTATIONS
[33]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 QUANTILE PLOT FOR GROSS GAMMA Survey Unit: S3-06105A-F Survey Unit Name: Turbine Building 560 ft Embedded Pipe Mean: 8.06E+05 pCi/m2 Quantile Plot For Co-60 2.50E+06 2.00E+06 Concentration (pCi/m2) 1.50E+06 1.00E+06 5.00E+05 0.00E+00 0% 20% 40% 60% 80% 100%
Percentage
[34]
FSS RELEASE RECORD TURBINE BUILDING 560 FT EL. EMBEDDED FLOOR DRAIN PIPE SURVEY UNIT 06105 HISTOGRAM FOR GROSS GAMMA Survey Unit: S3-06105A-F Survey Unit Name: Turbine Building 560 ft Embedded Pipe Mean: 8.06E+05 pCi/m2 Median: 8.26E+05 pCi/m2 ST DEV: 3.41E+05 Skew: 1.06E+00 Frequency Plot For Co-60 60%
50%
40%
Frequency 30%
20%
10%
0%
6.34E+05 1.03E+06 1.42E+06 1.82E+06 2.21E+06 Upper End Value (pCi/m2)
Upper Value Observation Observation %
Frequency 6.34E+05 68 51%
8.31E+05 21 16%
1.03E+06 3 2%
1.23E+06 23 17%
1.42E+06 10 8%
1.62E+06 5 4%
1.82E+06 2 2%
2.01E+06 1 1%
2.21E+06 0 0%
2.41E+06 0 0%
TOTAL 133 100%