ZION STATION RESTORATION PROJECT FINAL STATUS SURVEY RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[2]

PREPARED BY / DATE:

David Montt, Radiological Engineer REVIEWED BY / DATE:

Robert Massengill, Radiological Engineer APPROVED BY / DATE:

D. Wojtkowiak, C/LT Manager 2/28/2019 2/28/2019 2/28/2019

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[3]

TABLE OF CONTENTS

1.

EXECUTIVE

SUMMARY

..................................................................................................... 7

2.

SURVEY UNIT DESCRIPTION......................................................................................... 11

3.

CLASSIFICATION BASIS.................................................................................................. 16

4.

DATA QUALITY OBJECTIVES (DQO)........................................................................... 17

5.

SURVEY DESIGN................................................................................................................ 21

6.

SURVEY IMPLEMENTATION......................................................................................... 25

7.

SURVEY RESULTS............................................................................................................. 27

8.

QUALITY CONTROL......................................................................................................... 30

9.

INVESTIGATIONS AND RESULTS................................................................................. 30

10. REMEDIATION AND RESULTS....................................................................................... 30
11. CHANGES FROM THE FINAL STATUS SURVEY PLAN........................................... 31
12. DATA QUALITY ASSESSMENT (DQA).......................................................................... 31
13. ANOMALIES........................................................................................................................ 31
14. CONCLUSION...................................................................................................................... 31
15. REFERENCES...................................................................................................................... 32
16. ATTACHMENTS.................................................................................................................. 33 ATTACHMENT 1................................................................................................................... 34 ATTACHMENT 2................................................................................................................... 38 ATTACHMENT 3................................................................................................................. 117 ATTACHMENT 4................................................................................................................. 124 ATTACHMENT 5................................................................................................................. 126

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[4]

LIST OF FIGURES Figure 1 - Spent Fuel Transfer Tube Removed Leaving 8 x 8 Access.......................................... 9 Figure 2 - Recirculating Sump Suction Penetrations Grouted........................................................ 10 Figure 3 - Cavity Flood Sump Suction Penetrations Grouted........................................................ 10 LIST OF TABLES Table 1 - Summary of Unit 2 Containment Building Penetrations End State Lengths and Surface Areas from TSD 14-016............................................................... 11 Table 2 - Final Unit 2 Containment Building Penetrations End State Lengths and Surface Areas........................................................................................................... 12 Table 3 - Unit 2 Containment Building Penetrations...................................................................... 12 Table 4 - Dose Significant Radionuclides and Mixture.................................................................. 18 Table 5 - Base Case DCGLs for Containment, Auxiliary Building and Turbine Building Penetrations (BcDCGLPN) from LTP Chapter 5, Table 5-13......................................... 20 Table 6 - Operational DCGLs for Containment Penetrations (OpDCGLPN) from LTP Chapter 5, Table 5-14.................................................................................... 21 Table 7 - Containment Building Surrogate Ratios.......................................................................... 22 Table 8 - Survey Unit #S1-02112AF FSS Instrumentation and Action Levels.............................. 23 Table 9 - Investigation Levels......................................................................................................... 24 Table 10 - Systematic Static Locations for Hand-Held Survey...................................................... 25 Table 11 - Survey Unit 02112 Statistical Summary Using Containment BcDCGLPN................... 29 Table 12 - Survey Unit #02112 Statistical Summary Using Auxiliary Building BcDCGLPN........ 29 Table 13 - Survey Unit #02112 Statistical Summary Using Turbine Building BcDCGLPN.......... 30

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[5]

LIST OF ACRONYMS AND ABBREVIATIONS ALARA As Low As Reasonably Achievable AMCG Average Member of the Critical Group BFM Basement Fill Model CPM Counts Per Minute DCGL Derived Concentration Guideline Level DCGLPN Derived Concentration Guideline Level Penetration DPM Disintegrations Per Minute DQO Data Quality Objective FSS Final Status Survey GPS Global Positioning System GW Ground Water HTD Hard To Detect IC Insignificant Contributor ID Internal Diameter IMB Inner Missile Barrier LTP License Termination Plan MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual MDCR Minimal Detectable Count Rate NAD North American Datum NaI Sodium Iodide QC Quality Control OMB Outer Missile Barrier OpDCGL Operational Derived Concentration Guideline Level RE Radiological Engineer ROC Radionuclides of Concern SOF Sum-of-Fraction TEDE Total Effective Dose Equivalent

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[6]

TSD Technical Support Document UCL Upper Confidence Limit VCC Vertical Concrete Cask ZSRP Zion Station Restoration Project

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[7]

1.

EXECUTIVE

SUMMARY

This Final Status Survey (FSS) Release Record for Survey Unit #S1-02112AF, Unit 2 Containment Building Penetrations, has been generated for the Zion Station Restoration Project (ZSRP) in accordance with ZionSolutions procedure ZS-LT-300-001-005, Final Status Survey Data Reporting (Reference 1) and satisfies the requirements of Section 5.11 of the Zion Station Restoration Project License Termination Plan (LTP)

(Reference 2).

Three (3) Final Status Survey (FSS) sample plans (#S1-02112A-F #1, #S1-02112A-F #2,

  1. S1-02112A-F #3) were developed to perform this work in accordance with ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package Development (Reference 3), the ZSRP LTP, and with guidance from NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (Reference 4).

FSS was performed to demonstrate that the concentrations of residual radioactivity on the interior surfaces of the penetrations were equal to or below site-specific Derived Concentration Guideline Levels (DCGL) corresponding to the dose criterion in 10 CFR 20.1402. Initially, the penetrations were segregated and classified in accordance with the type of system and system use. However, in a conservative measure to ensure that all accessible surfaces within each end-state penetration would be subjected to FSS, the classification of all penetrations was changed to Class 1.

Two (2) different survey approaches were used for FSS depending on the diameter, length and access to the penetrations. FSS measurements acquired under FSS sample plans #1 and #2, which were applicable to penetrations with an internal diameter (ID) less than 12 inches, consisted of a static measurement taken at 1-foot intervals inside the pipe using a sodium iodide (NaI) detector, conservatively assuming a Field-of-View (FOV) of 1-foot for each measurement and thus providing 100% areal coverage of the accessible internal surfaces of the pipe.

FSS measurements acquired under FSS sample plan #3, which was applicable to penetrations with an internal diameter (ID) greater than 12 inches, consisted of a 100%

scan with a hand-held detector of the interior surface area of the pipe and at least one (1) 1-minute static measurement at a biased location based on the highest scan reading. For the five (5) 24 inch diameter penetrations encompassing the Recirculating Pump Suction and Cavity Floor Sump suction pipes (removed), the sodium iodide detector was used (FSS sample plan #2) with recalculated efficiencies for a 24 inch diameter penetration permitting one foot interval static counts along the 50 foot length of each of these. All five were subsequently grouted. See Figures 2 and 3.

For the FSS of the Unit 2 Containment Building Penetrations, three hundred and sixty-nine (369) measurements were obtained. No single measurement taken in any penetration

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[8]

exceeded a sum of fraction (SOF) of one (1) when compared against the Operational DCGLs for Containment Penetrations. The FSS results produced a mean SOF for the survey unit of 0.00824, which equates to a mean dose of 0.2060 mrem/yr. LTP Chapter 6, section 6.4.5 states, The dose from penetrations is summed with the dose from the wall and floor surfaces of both basements that the penetration interface. The Containment penetrations interfaced with the Auxiliary Building and the Turbine Building (through the East and West Main Steam Valve Houses). Consequently, the FSS design employed the DCGLs for the Containment penetrations, which was the most limiting. However, the mean concentration for each Radionuclide-of-Concern (ROC) was compared against the Base Case Penetration DCGLs (BcDCGLPN) for the Auxiliary Building and Turbine Building as well. The resultant dose was added to each Basement to ensure compliance with the LTP.

The mean Sum-of-Fraction (SOF) using the Operational DCGL (OpDCGLPN) for Containment penetrations was 0.00823. None of the measurements exceeded the OpDCGLPN for Containment penetrations. The maximum Operational SOF (OpSOF) for a single measurement using OpDCGLPN for Unit 2 Containment penetrations was 0.6849.

The FSS results produced a mean BcSOF, compared against the BcDCGLPN for the Containment of 0.00823, which equates to a mean dose of 0.2058 mrem/yr. The mean BcSOF for the penetrations that interfaced with the Auxiliary Building, when compared against the BcDCGLPN for the Auxiliary Building was 0.0095, which equates to a mean dose of 0.2386 mrem/yr. The mean BcSOF for the penetrations that interfaced with the Turbine Building, when compared against the BcDCGLPN for the Turbine Building was 0.0002, which equates to a mean dose of 0.0054 mrem/yr.

Penetration No. 249, Fuel Transfer Tube, was completely removed and shipped off site as waste. It was a 24 inch penetration and was completely removed leaving an approximate eight by eight foot opening that facilitated personnel and ISOCS access for the Spent Fuel Building and Transfer Canal final status survey. In accordance with LTP Chapter 5 section 5.5.5, nineteen (19) of the penetrations required grouting as they had measurements with activity greater than the Operational DCGLs for the Containment Building structure. However, ZSRP decided to completely remove fourteen (14) of the Unit 2 Containment Building Penetrations during Containment demolition. Consequently, only five (5) Unit 1 Containment Building Penetrations were grouted; see Figures 2 and 3.

No dose reduction was attributed to the survey unit because of grouting.

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[9]

Figure 1 - Spent Fuel Transfer Tube Removed Leaving 8 x 8 Access

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[10]

Figure 2 - Recirculating Sump Suction Penetrations Grouted Figure 3 - Cavity Flood Sump Suction Penetrations Grouted

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[11]

2.

SURVEY UNIT DESCRIPTION In accordance with the definition of penetrations specified in LTP Chapter 5, section 5.5.5, The end state will include embedded piping and penetrations. An embedded pipe is defined as a pipe that runs vertically through a concrete wall or horizontally through a concrete floor and is contained within a given building. A penetration is defined as a pipe (or remaining pipe sleeve, if the pipe is removed, or concrete, if the pipe and pipe sleeve is removed) that runs through a concrete wall and/or floor, between two buildings, and is open at the wall or floor surface of each building. A penetration could also be a pipe that runs through a concrete wall and/or floor and opens to a building on one end and the outside ground on the other end.

The Unit 2 Containment Building Penetrations survey unit consists of sixty-two (62) penetrations ranging from six (6) inches to fifty (50) inches in diameter. A summary of the original End State lengths and surface areas for the Unit 2 Containment Building Penetrations as depicted in ZionSolutions Technical Support Document (TSD)14-016, Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State (Reference 5) is provided in Table 1 below.

Table 1 - Summary of Unit 2 Containment Building Penetrations End State Lengths and Surface Areas from TSD 14-016 Unit 2 End State Sum of Length(m)

Sum of Length (ft)

Sum of Interior Surface Area (m2)

Open Sleeve 88.19 289.34 119.99 Pipe in Sleeve 81.01 265.78 122.37 Total 169.20 555.12 242.36 The End State condition depicted in TSD 14-016 was altered due to D&D activities and observations made during survey design and walk-down. Eight (8) penetrations listed for Unit 2 Containment in TSD 14-016 are above the basement End State 588 elevation and were not included as part of the FSS. Five (5) penetrations residing in the Recirculating Water Sump and Cavity Flood Sump had an original End State of pipe in sleeve; the D&D contractor removed the piping within the penetrations, leaving only a larger diameter open sleeve for each of the five penetrations. Additionally, a section of wall housing one (1) penetration (the Fuel Transfer Tube) was demolished to allow access to the building, which brings the total number of penetrations to sixty-one (61); See Figure 1.

In accordance with LTP Chapter 5, section 5.5.5, penetration survey units have total surface area that is less than the area of the wall/floor surface survey unit that the penetrations interface. To eliminate the potential for activity levels in penetrations that could lead to releases greater than the adjacent basement walls and floors, the following

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[12]

remediation and grouting action levels were applied to measurements of surface activity in penetrations.

  • If maximum activity exceeded the Base Case DCGLPN from Table 5-13 (BcSOF >1),

then remediation was performed.

  • If the maximum activity in a penetration exceeded the most limiting Operational DCGLB from Table 5-4 of the two basements where a penetrations interface (OpSOF>1), but is below the Base Case DCGLPN from Table 5-13, then the penetration was remediated or grouted.
  • If a penetration was remediated and the maximum activity continued to exceed the most limiting Operational DCGLB from Table 5-4 of the two basements where a penetrations interface (OpSOF>1), but was less than the Operational DCGLPN, then the penetration was grouted.
  • If the maximum activity was below the surface Operational DCGLB from Table 5-4, then grouting of the penetration was not required.

Table 2 provides a summary of the final lengths and surface areas for the FSS of Unit 2 Containment Building Penetrations. The list and descriptions of the penetrations is provided in Table 3. A layout of the Unit 2 Containment Building Penetrations is provided in Figure 1 on Attachment 1.

Table 2 - Final Unit 2 Containment Building Penetrations End State Lengths and Surface Areas Unit 2 End State Sum of Length (m)

Sum of Length (ft)

Sum of Interior Surface Area (m2)

Open Sleeve 154.88 508.14 253.36 Total 154.88 508.14 253.36 Table 3 - Unit 2 Containment Building Penetrations Penetration No.

Description Class Diameter (in)

Surface Area (m2)

Length (ft)

Length (m)

P201 Fire Protection 3

10 1.18 4.83 1.47 P203 Spare 2

6 0.71 4.83 1.47 P204 Boron Injection Tank to Cold Legs 1

8 0.94 4.83 1.47 P205 Main Steam 2

50 4.86 4

1.22 P206 Main Steam 2

50 4.86 4

1.22

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[13]

Penetration No.

Description Class Diameter (in)

Surface Area (m2)

Length (ft)

Length (m)

P207 Main Steam 2

50 4.86 4

1.22 P208 Main Steam 2

50 4.86 4

1.22 P209 Feedwater 2

32 3.11 4

1.22 P210 Feedwater 2

32 3.11 4

1.22 P211 Feedwater 2

32 3.11 4

1.22 P212 Feedwater 2

32 3.11 4

1.22 P217 Reactor Coolant No. 1 Loop to Residual Heat Removal Pumps 1

28 3.29 4.83 1.47 P218 Cavity Fill Pump 1A Discharge 1

18 2.12 4.83 1.47 P219 Component Cooling Water Supply Header to RCPs 2

12 1.41 4.83 1.47 P220 Cavity Fill Pump 1B Discharge 1

18 2.12 4.83 1.47 P221 Spare 2

28 3.29 4.83 1.47 P222 Residual Heat Exchanger to RC Loop Cold Legs 1

28 3.29 4.83 1.47 P223 RC Pumps to Comp Cooling Pump Suction 2

12 1.41 4.83 1.47 P235 Recirculating Sump Suction 1

24 29.87 51.17 15.60 P236 Cavity Flood Sump Suction 1

24 29.62 50.75 15.47 P237 Cavity Flood Sump Suction 1

24 29.67 50.83 15.49 P242 CTMT Sump Pump Discharge to Aux Bldg. Floor Drain Analysis Tank 1

6 0.71 4.83 1.47 P243 RC Drain Pump Discharge to Hold-Up Tank 1

8 0.94 4.83 1.47 P249 Fuel Transfer Tube (removed) 1 24 N/A 8.21 2.50 P250 Spare 2

10 1.18 4.83 1.47 P254 Containment Pressure 2

6 0.71 4.83 1.47

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[14]

Penetration No.

Description Class Diameter (in)

Surface Area (m2)

Length (ft)

Length (m)

P256 Filtered Vents 2

8 0.94 4.83 1.47 P264 Spare 2

8 0.94 4.83 1.47 P266 RC Pump Seal Water Supply Lines 2

14 1.65 4.83 1.47 P267 Spare 2

18 2.12 4.83 1.47 P268 Aux Feedwater to Steam Gen 1C 2

14 1.65 4.83 1.47 P269 Aux Feedwater to Steam Gen 1A 2

14 1.65 4.83 1.47 P270 Refueling Cavity Drain to Purification Pump Suction 1

14 1.65 4.83 1.47 P273 Spare 2

18 2.12 4.83 1.47 P274 Aux Feedwater to Steam Gen 1D 2

14 1.65 4.83 1.47 P281 Non-Filtered Vents 2

8 0.94 4.83 1.47 P286 Press Stem, Press Liq, RC Hot Leg Samples 2

10 1.18 4.83 1.47 P287 Spare 2

10 1.18 4.83 1.47 P288 Heating System Hot Water Supply 2

12 1.41 4.83 1.47 P289 Heating System Hot Water Return 2

12 1.41 4.83 1.47 P290 Spare 2

28 3.29 4.83 1.47 P291 Blowdown Steam Generator 1A 2

16 1.56 4

1.22 P292 Blowdown Steam Generator 1A 2

16 1.56 4

1.22 P293 Blowdown Steam Generator 1C 2

16 1.56 4

1.22 P294 Blowdown Steam Generator 1C 2

16 1.56 4

1.22

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[15]

Penetration No.

Description Class Diameter (in)

Surface Area (m2)

Length (ft)

Length (m)

P295 Blowdown Steam Generator 1A 2

14 1.36 4

1.22 P296 Blowdown Steam Generator 1C 2

14 1.36 4

1.22 P297 Blowdown Steam Generator 1D 2

14 1.36 4

1.22 P298 Blowdown Steam Generator 1B 2

14 1.36 4

1.22 P303 Spare 2

8 0.94 4.83 1.47 P304 SIM to Aux F.S. Pumps 1

24 2.82 4.83 1.47 P305 Residual Heat Exchanger to RC Loop Hot Legs 1

18 2.12 4.83 1.47 P312 Steam Generator Blowdown Sample 2

16 1.56 4

1.22 P313 Steam Generator Blowdown Sample 2

16 1.56 4

1.22 P315 Blowdown (Steam Generator 1D) 2 16 1.56 4

1.22 P316 Blowdown (Steam Generator 1D) 2 16 1.56 4

1.22 P317 Blowdown (Steam Generator 1B) 2 16 1.56 4

1.22 P318 Blowdown (Steam Generator 1B) 2 16 1.56 4

1.22 P323 Recirculating Sump Suction 1

24 30.35 52 15.85 P324 Recirculating Sump Suction 1

24 30.84 52.83 16.10 P327 Steam to Aux FW Pumps 2

16 1.56 4

1.22 P328 Steam to Aux FW Pumps 2

16 1.56 4

1.22

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[16]

Penetrations P205, P206, P207, P208. P209, P210, P211, P212, P291, P292, P293, P294, P295, P296, P297, P298, P312, P313, P315, P316, P317, P318, P327 and P328 interfaced between the Unit 2 Containment and the Turbine Building, through the Unit 2 East and West Main Steam Valve Houses. All other penetrations interfaced between Unit 2 Containment and the Auxiliary Building.

3.

CLASSIFICATION BASIS Survey Unit #S1-02112AF was classified in accordance with ZionSolutions procedure ZS-LT-300-001-002, Survey Unit Classification (Reference 6).

The Unit 2 Containment Building Penetrations were initially classified as Class 1, Class 2, or Class 3, (see Table 3 above), based on historical assessment, exposure to radioactive materials and system use. As a conservative measure, the classifications of all Unit 2 Containment Building Penetrations were changed to Class 1. Consequently, sufficient measurements were taken in all Unit 2 Containment Building Penetrations to ensure 100%

areal coverage of all accessible internal surfaces within the penetrations.

The Unit 2 Containment housed numerous systems containing primary coolant as well as radioactively contaminated support systems. System leakage and maintenance activities over the operating life of the reactor resulted in the radiological contamination of most of the interior surfaces of the structures. Some components, equipment, structural steel and concrete became radioactive due to neutron activation. Based on the building design basis and the operating history, all internal survey units in Unit 2 Containment Building were given an initial classification of Class 1 in accordance with the Zion Station Historical Site Assessment (HSA) (Reference 7).

The Unit 2 Containment Building housed the Unit 2 Reactor Vessel, Steam Generators, and Pressurizers. The Unit 2 Containment Penetrations were building to building pipe pathways for various primary and secondary systems. The location of the penetrations, their function, and the operational history of the Unit 2 Containment Building support the initial classifications. Those shared with the Auxiliary Building and the Turbine Building are included here, as including them here is more conservative with Unit 2 Penetrations surrogate ratios and OpDCGLPN applied than using those for the Auxiliary Building.

From June of 2012 through January of 2013, site characterization was performed in Unit 2 Containment. The results of the site characterization surveys performed from 2010 to 2013 are documented in ZionSolutions TSD 14-028, Radiological Characterization Report (Reference 8) and in Chapter 2 of the LTP. During the time that initial characterization was performed, all radioactive systems and components were still located inside Containment. Consequently, ambient radiation dose rates inside the Containment

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[17]

prohibited the direct assessment of penetrations or system interior surfaces by scanning or direct measurement.

On 07/20/16, the last routine surveys were conducted in Unit 2 Containment, before heavy demolition started and access was no longer possible. Survey 2016-2226, conducted in the Outer Missile Barrier (OMB) area of Unit 2, showed that all smears were less than 1,000 dpm/100cm2 and that the maximum dose rate was 1.5 mR/hr. Survey 2016-2224, conducted in the Inner Missile Barrier (IMB) area of Unit 2, showed a maximum loose contamination level of 6,400 dpm/100cm2 and a maximum dose rate of 5.1 mR/hr.

A Radiological Engineer (RE) performed the visual inspection and walk-down of the survey unit on December 12, 2017. The purpose of the walk-down was to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions. A final classification assessment was performed in accordance with procedure ZS-LT-300-001-002, Survey Unit Classification as part of the survey design for FSS.

The Unit 2 Containment Building Penetrations were initially classified as Class 1, Class 2, or Class 3, based on historical assessment, exposure to radioactive materials and system use. Based upon completion of the Survey Unit Classification Basis for final classification, which included a review of the historical information, the results of the Characterization Survey data and, completion of a final Survey Unit Classification Worksheet, the correct final classification of penetrations within Unit 2 were validated.

As a conservative measure, the classifications of all Unit 2 Containment Building Penetrations were changed to Class 1. Consequently, sufficient measurements were taken in all Unit 2 Containment Building Penetrations to ensure 100% areal coverage of all accessible internal surfaces within the penetrations.

4.

DATA QUALITY OBJECTIVES (DQO)

Final Status Survey planning and design hinges on coherence with the Data Quality Objective (DQO) process to ensure, through compliance with explicitly defined inputs and boundaries, that the primary objective of the survey is satisfied. The DQO process is described in the ZSRP LTP in accordance with MARSSIM. The appropriate design for a given survey will be developed using the DQO process as outlined in Appendix D of MARSSIM.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[18]

for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit would satisfy the primary objective of the FSS sample plan.

The primary objective of the FSS sample plan is to demonstrate that the level of residual radioactivity in the penetrations that comprised survey unit 02112 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

ZionSolutions TSD 11-001, Potential Radionuclides of Concern during the Decommissioning of Zion Station (Reference 9) established the basis for an initial suite of potential ROC for the decommissioning of the Zion Nuclear Power Station (ZNPS).

LTP Chapter 6, section 6.5.2 discusses the process used to derive the ROC for the decommissioning of ZNPS, including the elimination of insignificant dose contributors (IC) from the initial suite. Table 4 presents the ROC for the Containment Basement structural surfaces and the normalized fractions based on the radionuclide mixture.

Table 4 - Dose Significant Radionuclides and Mixture Radionuclide

% of Total Activity (normalized)(1)

H-3 0.08%

Co-60 4.72%

Ni-63 26.50%

Sr-90 0.03%

Cs-134 0.01%

Cs-137 68.17%

Eu-152 0.44%

Eu-154 0.06%

(1) Based on maximum percent of total activity from Table 20 of TSD 14-019, normalized to one for the dose significant radionuclides.

A penetration is defined in the LTP as a pipe (or remaining pipe sleeve, if the pipe is removed, or concrete, if the pipe and pipe sleeve are removed) that runs through a concrete wall and/or floor, between two buildings, and is open at the wall or floor surface of each building. A penetration could also be a pipe that runs through a concrete wall and/or floor and opens to a building on one end and the outside ground on the other end.

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[19]

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs.

The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for penetrations.

The End State Basements are comprised of steel and/or concrete structures which will be covered by at least three feet of clean soil and physically altered to a condition which would not realistically allow the remaining structures, if excavated, to be occupied. The exposure pathways in the Basement Fill Model (BFM) are associated with residual radioactivity in floors and walls that is released through leaching into water contained in the interstitial spaces of the fill material. The BFM assumes that the inventory of residual radioactivity in a given building is released either instantly or over time by diffusion, depending on whether the activity is surficial or volumetric, respectively. The activity released into the fill water will adsorb onto the clean fill, as a function of the radionuclide-specific distribution coefficients, resulting in equilibrium concentrations between the fill and the water. Consequently, the only potential exposure pathways after backfill, assuming the as-left geometry, are associated with the residual radioactivity in the water contained in the fill.

The final outputs of the BFM are the Penetration DCGLs, in units of pCi/m2, which are calculated using the BFM Groundwater (GW) and BFM Drilling Spoils Dose Factors (LTP Chapter 6, Tables 6-24 and 6-25) using Equation 6-9. The BcDCGLPN are radionuclide-specific concentrations that represent the 10 CFR 20.1402 dose criterion of 25 mrem/year and are calculated for each ROC and each backfilled Basement. The unity rule is applied when there is more than one ROC. The measurement results for each singular ROC present in the mixture are compared against their respective DCGL to derive a dose fraction.

The BcDCGLPN for the unrestricted release of the Unit 2 Containment Basement penetrations are provided in Table 5. The IC dose percentage of 10% was used to adjust the Containment Basement DCGLPN to account for the dose from the eliminated IC radionuclides. The BcDCGLPNs, for the unrestricted release of the Auxiliary Building and Turbine Building Basement penetrations, are also provided in Table 5. The IC dose percentage of 5% was used to adjust the Auxiliary Building and Turbine Building Basement BcDCGLPN to account for the dose from the eliminated IC radionuclides.

Each radionuclide-specific BcDCGLPN is equivalent to the level of residual radioactivity (above background levels) that could, when considered independently, result in a Total Effective Dose Equivalent (TEDE) of 25 mrem per year to an Average Member of the Critical Group (AMCG). To ensure that the summation of dose from each source term is 25 mrem/year or less after all FSS is completed, the BcDCGLPN are reduced based on an

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[20]

expected, or a priori, fraction of the 25 mrem/year dose limit from each source term. The reduced DCGLPN, or Operational DCGLPN can be related to the BcDCGLPN as an expected fraction of dose based on an a priori assessment of what the expected dose should be based on the results of site characterization, process knowledge and the extent of planned remediation. The OpDCGLPN is then used as the DCGL for the FSS design of the survey unit (calculation of surrogate DCGLs, investigations levels, etc.). Details of the OpDCGLPN derived for each dose component and the basis for the applied a priori dose fractions are provided in ZionSolutions TSD 17-004, Operational Derived Concentration Guideline Levels for FSS (Reference 10).

Table 5 - Base Case DCGLs for Containment, Auxiliary Building and Turbine Building Penetrations (BcDCGLPN) from LTP Chapter 5, Table 5-13 Radionuclide Containment BcDCGLPN (pCi/m2)

Auxiliary Building BcDCGLPN (pCi/m2)

Turbine Building BcDCGLPN (pCi/m2)

H-3 3.42E+09 3.99E+09 3.23E+09 Co-60 2.26E+09 8.82E+07 1.76E+09 Ni-63 5.78E+10 6.79E+10 5.48E+10 Sr-90 2.06E+07 2.41E+07 1.94E+07 Cs-134 4.32E+08 3.28E+08 4.00E+08 Cs-137 5.66E+08 6.17E+08 5.29E+08 Eu-152 5.26E+09 3.29E+08 4.06E+09 Eu-154 4.58E+09 2.33E+08 3.58E+09 Survey design and investigations used the most limiting OpDCGLPN of the three basements that were impacted by the penetration, which belonged to the Containment.

The OpCGLPN for the unrestricted release of the Containment Basement penetrations are provided in Table 6.

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[21]

Table 6 - Operational DCGLs for Containment Penetrations (OpDCGLPN) from LTP Chapter 5, Table 5-14 Radionuclide Containment OpDCGLPN (pCi/m2)

H-3 2.33E+08 Co-60 1.54E+08 Ni-63 3.93E+09 Sr-90 1.40E+06 Cs-134 2.94E+07 Cs-137 3.85E+07 Eu-152 3.58E+08 Eu-154 3.11E+08 Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the Operational DCGL. Survey instrument response checks were required prior to issuance and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data. The minimum acceptable MDC for measurements obtained using field instruments was 50 percent of the applicable Operational DCGL.

5.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in procedure ZS-LT-300-001-001 Final Status Survey Package Development. The FSS plan uses a sample design that combines hand-held scanning with static measurements and pipe detector survey methodologies.

Section 5.1 of LTP Chapter 5 states that H-3, Co-60, Ni-63, Sr-90, Cs-134, Cs-137, Eu-152, and Eu-154 would be the ROC in Survey Unit #S1-02112AF. During FSS, concentrations for Hard-to-Detect (HTD) ROC H-3, Ni-63, and Sr-90 are inferred using a surrogate approach. Cs-137 is the principle surrogate radionuclide for H-3 and Sr-90, and Co-60 is the principle surrogate radionuclide for Ni-63. The mean, maximum and 95%

Upper Confidence Level (UCL) of the surrogate ratios for concrete core samples taken in the U1/U2 Containment Building basements were calculated in ZionSolutions TSD 14-019, Radionuclides of Concern for Soil and Basement Fill Model Source Terms (Reference 11) and are presented in Table 7. The maximum ratios were used in the surrogate calculations during FSS.

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[22]

Table 7 - Containment Building Surrogate Ratios Ratios Containment Building Mean Max 95%UCL H-3/Cs-137 0.208 1.760 0.961 Ni-63/Co-60 30.623 442 193.910 Sr-90/Cs-137 0.002 0.021 0.010 For the FSS of Survey Unit #S1-02112AF, the surrogate OpDCGLPNs for Co-60 and Cs-137 were computed based on the maximum ratios from Table 7.

The equation for calculating a surrogate DCGL is as follows:

Equation 1

=

1

1

+

2 2+

3 3+

Where:

DCGLSur

= Surrogate radionuclide DCGL DCGL2,3n = DCGL for radionuclides to be represented by the surrogate Rn

= Ratio of concentration (or nuclide mixture fraction) of radionuclide n to surrogate radionuclide Using the OpDCGLPNs presented in Table 6 and the maximum ratios from Table 7, the following surrogate calculations were performed:

Equation 2 (137) =

1

1 3.8507(137)+

1.76 2.3308(3)+

0.021 1.4006(90)

= 2.0607 /2 The surrogate OpDCGLPN that was used for Cs-137 in this survey unit for direct comparison of sample results to demonstrate compliance is 2.06E+07 pCi/m2.

Equation 3 (60) =

1

1 1.5408(60)+

442 3.9309(63)

= 8.4106 /2

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[23]

The surrogate OpDCGLPN that was used for Co-60 in this survey unit for direct comparison of sample results to demonstrate compliance is 8.41E+06 pCi/m2.

The most limiting OpDCGLPN was determined to be Co-60 (8.41E+06 pCi/m2) or 1.87E+05 dpm/100 cm2. This was the action level for hand-held scan and static measurements and pipe detector static measurements in this survey unit. Action levels in counts per minute (cpm) for pipe detector surveys were calculated using the limiting Co-60 OpDCGLPN (1.87E+05 dpm/100cm2), the effective area of detection for the various diameter penetrations, and the limiting efficiency for each size penetration. The action levels in cpm for hand-held surveys were calculated using the limiting Co-60 OpDCGLPN and the efficiency of the instrument/detector combo. Table 8 provides a breakdown of the instrumentation, detector combo efficiencies and action levels used to assess the FSS results of the Unit 2 Containment Building Penetrations.

Table 8 - Survey Unit #S1-02112AF FSS Instrumentation and Action Levels Survey Type Instrument Detector Penetration Diameter (in)

Efficiency Action Level (cpm)(1)

Hand-held Ludlum 2350-1 Ludlum 43-68 14-50 0.2975(1) 53,620 Ludlum 2360 Ludlum 43-93 14-50 0.129(2) 24,160 Pipe Detector Ludlum 2350-1 Ludlum 44-157 6

0.012(3) 32,695 8

0.009(3) 32,751 Ludlum 44-162 10 0.018(3) 81,625 12 0.016(3) 87,186 23 0.0142(3) 148,131

1)

Efficiency determined using Tc-99 source. Derived instrument efficiency of 0.3673 x source efficiency of 0.81 (NUREG-1507, Table 5.4) = 0.2975 (total efficiency)

2)

Efficiency determined using Tc-99 source. Derived instrument efficiency of 0.1593 x source efficiency of 0.81 (NUREG-1507, Table 5.4) = 0.129 (total efficiency)

3)

Efficiency empirically derived using conformable Cs-137 source in various ID pipe jigs For this Class 1 basement survey unit, the Investigation Levels for area scanning and static measurement results are those levels specified in LTP Chapter 5, Table 5-25 and are reproduced below in Table 9.

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[24]

Table 9 - Investigation Levels Classification Scan Investigation Levels Direct Investigation Levels Class 1

>Operational DCGL or

>MDCscan if MDCscan is greater than Operational DCGL

>Operational DCGL Two (2) survey methodologies were utilized for the FSS of the Unit 2 Containment Building Penetrations, pipe detector survey or hand-held survey. This was due to the varying diameters and lengths of the penetrations. The survey designs for the FSS of Survey Unit #S1-02112AF using the different methodologies are detailed below.

Sample plans #1 and #2 required that measurements be collected with a pipe detector.

Penetrations included in plans #1 and #2 were twelve (12) inches in diameter or smaller, with the exception of the five (5) sump penetrations (23 ID) which were designated to be surveyed with a pipe detector because of their length (approximately 50 ft each). Twenty-two (22) of the sixty-one (61) total penetrations were included in the survey design for pipe detectors. Refer to Table 8 for the FSS instrumentation summary. The total length of the penetrations under the pipe detector methodology is 339.69 ft (103.54 m) with a total interior surface area of 162.22 m2. As a Class 1 survey unit, the survey design required a 100% areal coverage. For the survey of pipe or penetration internal surfaces that cannot be practically surveyed using a hand-held detector methodology, areal coverage is achieved by the area of detection for each static measurement taken. Scanning, in the traditional context, is not applicable to this type of survey. With a 1-foot area of detection, one (1) 1-minute static measurement at 1-foot increments throughout the penetration was sufficient to provide 100% areal coverage. For 339.69 feet of penetrations in the survey unit, at least 339 measurements were required to satisfy the 100% coverage requirement.

Sample plan #3 required that measurements be collected with a hand-held detector.

Penetrations included in sample plan #3 were larger than twelve (12) inches in diameter.

Thirty-nine (39) of the sixty-one (61) total penetrations were included in the survey design for hand-held detectors. Refer to Table 8 for the FSS instrumentation summary. The total length of the penetrations under the hand-held methodology is 168.45 ft (51.34 m) with a total interior surface area of 90.87 m2. For the survey of these larger diameter pipes, 100% of the interior surfaces required scanning and at least one (1) 1-minute static measurement at a systematic location or based on highest scan indication was required in each penetration. The sixteen (16) systematic static measurement locations are denoted in Table 10 below. The locations were developed using Visual Sample Plan (VSP) using a pre-determined number of samples (16) with a random start point on a triangular grid superimposed on the laid out interior surface area of the relevant penetrations. See for the VSP graphic.

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[25]

Table 10 - Systematic Static Locations for Hand-Held Survey Measurement No.

Penetration No.

Inches into Penetration Inches Clockwise from 12 oclock 1

P205 13 26 2

P205 13 136 3

P207 13 81 4

P209 12 26 5

P211 12 81 6

P217 11 26 7

P221 28 26 8

P266 5

26 9

P269 22 26 10 P274 39 26 11 P290 14 80 12 P292 13 25 13 P296 12 25 14 P305 1

25 15 P315 38 25 16 P327 37 25 The survey designs required, in total, three hundred and eighty nine (389; 369 measurements and 20 QCs) static measurements for the FSS of the Unit 2 Containment Building Penetrations.

Maps of the penetrations and measurement locations are provided in Attachment 1.

The implementation of quality control measures as referenced by LTP Chapter 5, section 5.9 and ZionSolutions ZS-LT-01, Quality Assurance Project Plan (for Characterization and FSS) (QAPP) (Reference 12) includes the collection of a duplicate measurement on 5% of the measurements taken with the locations selected at random. One (1) measurement out of every twenty (20) was required for QC compliance.

6.

SURVEY IMPLEMENTATION Survey instructions for this FSS were incorporated into and performed in accordance with FSS Sample Plans #S1-02112AF #1, #2, and #3, which were developed in accordance with ZionSolutions procedure ZS-LT-300-001-001, Final Status Survey Package

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[26]

Development. The FSS unit was inspected and controlled in accordance with ZionSolutions procedure ZS-LT-300-001-003, Isolation and Control for Final Status Survey (Reference 13).

Surveys of the Unit 2 Containment Building Penetrations began on January 4, 2018 and concluded on April 19, 2018. The survey design estimated six (6) working days to implement the FSS in parallel with any required decontamination and inspection activities.

In reality, ten (10) working days were necessary to complete this work. Throughout these activities, briefings were conducted on a daily basis to discuss the expectations for job performance and to review the safety aspects of the job.

Visual inspections of the penetrations were performed prior to the start of the survey.

Inspections were performed to ensure that the penetrations were relatively dry and free of debris.

For pipe detector surveys, a background value was determined for the detector/instrument combination to be used prior to deployment. The background value was obtained at the location where the pre-use response check of the instrument was performed. The background value was primarily used to ensure that the detector had not become cross-contaminated by any previous use. Background was not subtracted from any measurement.

Daily, prior to and following use, each detector was subjected to an Operational Response Check in accordance with procedure ZS-LT-300-001-006, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors (Reference 14). The Daily Operational Response Check compared the background response and the response to check sources ranges established for normal background and detector source response to ensure that the detector was working properly.

Once the detector was determined to be fully functional, it was then deployed to the field for insertion into the targeted piping. A one-minute static measurement was acquired at each foot traversed into the pipe. The detector output represented the gamma activity for each one-minute timed measurement in units of gross cpm. The gamma measurement value in units of cpm was then converted to units of dpm using the efficiency factor for the detector applicable to the diameter of the pipe surveyed.

Each measurement assumed a conservative area of detection for the NaI detector of one foot. This assumption is conservative because there is additional instrument response from contamination located in the pipe at distances outside of the area of detection.

Consequently, the total activity from the measurement, in units of dpm is adjusted for the total effective surface area commensurate with the pipe diameter and the assumed area of detection, resulting in measurement results in units of dpm/100 cm2. Using the appropriate conversion factors, the result is then converted to units of pCi/m2. This

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[27]

measurement result represents a commensurate and conservative gamma surface activity for the one foot of pipe surface where the measurement was taken.

For the hand-held detector surveys of larger diameter penetrations, a background value was determined for the detector/instrument combination as the average of five (5) ambient 1-minute static measurements. An Alarm Set Point was developed using the background value plus the Action Levels dictated in Table 8.

The entire surface area (100%) of the interior surface area of the designated penetrations were scanned using either the Ludlum 2350-1 paired with a Ludlum 43-68 detector or a Ludlum 2360 paired with a Ludlum 43-93 detector operated in the rate-meter mode and using audio response. The probe was positioned as close to the surface as possible and was moved at a scan speed of 0.25 meters per second.

Systematic 1-minute static measurements were acquired at the locations denoted in Table

10. Additionally, 1-minute static measurements were taken at the locations of highest scan indication in all the remaining penetrations. Using the established efficiencies (denoted in Table 8), the static measurement activities in cpm were converted to activities in dpm and then to pCi/m2 using the appropriate conversion factor.
7.

SURVEY RESULTS After completion of the FSS measurements in the penetrations, the sample plan was reviewed to confirm the completeness of the survey and the survey data was validated in accordance with procedure ZS-LT-300-001-004, Final Status Survey Data Assessment (Reference 15). Data processing includes converting measurement data into reporting units, validating instrument applicability and sensitivity, calculating relevant statistical quantities, and verification that all DQO have been met.

For measurements acquired with a NaI detector, the gross output of the measurement is converted to units of dpm by dividing by the efficiency. The effective FOV of the measurement is calculated based upon diameter of the pipe at a length of 1 foot. The result, following unit conversion, is a gross gamma measurement result in units of pCi/m2.

For measurements acquired as a direct static measurement with a hand-held detector, the gross gamma output of the measurement is again converted to units of dpm by dividing by the efficiency. As the detector has an area of 100 cm2, the units for the measurement are actually in units of dpm/100cm2. Again, through unit conversion, units of dpm/100cm2 are converted to units of pCi/m2.

Using the mixture from Table 5-2 of LTP Chapter 5 (reproduced as Table 4 of this Release Record), the gross gamma result from each measurement is multiplied by the normalized gamma mixture fractions for C-60, Cs-134 and Cs-137 to derive a radionuclide specific concentration for each gamma ROC. The HTD ROC concentrations

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[28]

for Ni-63 and Sr-90 were then inferred using the maximum surrogate ratios from LTP Chapter 5, Table 5-15 (reproduced as Table 7 of this Release Record). Each concentration for each measurement is then compared against the OpDCGL to produce a OpSOF for each ROC, which when summed results in a OpSOF for the measurement.

LTP Chapter 6, section 6.4.5 states, The dose from penetrations is summed with the dose from the wall and floor surfaces of both basements that the penetration interfaces. The Containment penetrations interfaced with the Auxiliary Building and the Turbine Building (through the East and West Main Steam Valve Houses). Consequently, the FSS design employed the OpDCGLPN for the Containment penetrations, which was the most limiting.

However, the mean concentration for each ROC was compared against the BcDCGLPN for the Containment as well as the Auxiliary Building and Turbine Building. The resultant dose was added to each Basement for compliance.

The OpSOF for seventy-seven (77) measurements, based on the OpDCGLB, were above one (1). In accordance with LTP Chapter 5 section 5.5.5, nineteen (19) of the penetrations required grouting as they had measurements with activity greater than the Operational DCGLs for the Containment Building structure. However, ZSRP decided to completely remove fourteen (14) of the Unit 2 Containment Building Penetrations during Containment demolition. Consequently, only five (5) Unit 2 Containment Building Penetrations were grouted. No dose reduction was attributed to the survey unit because of grouting.

The results of the data assessment for the Unit 2 Containment Building Penetrations are provided in Attachment 2. The data collected passed the Sign Test. The result of the Sign Test is provided in Attachment 3.

The OpSOF for all three hundred and sixty-nine (369) measurements, based on the OpDCGLPN, were below one (1). The mean OpSOF using the OpDCGLPN for Containment penetrations was 0.0082. The maximum OpSOF for a single measurement when compared against the OpDCGLPN was 0.6849.

The mean BcSOF for the systematic measurement population, when compared against the BcDCGLPN for the Containments, Auxiliary Building and Turbine Building are presented in Tables 11, 12 and 13.

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[29]

Table 11 - Survey Unit 02112 Statistical Summary Using Containment BcDCGLPN ROC Mean Conc Median Max Conc Min Conc STD Base Case DCGLPN Nuclide Mean SOF (BcSOFPN)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

H-3 3.75E+06 3.48E+06 2.12E+07 4.10E+04 2.80E+06 3.42E+09 0.00110 Co-60 1.48E+05 1.37E+05 8.35E+05 1.61E+03 1.10E+05 2.26E+09 0.00007 Ni-63 6.53E+07 6.05E+07 3.69E+08 7.12E+05 4.87E+07 5.78E+10 0.00113 Sr-90 4.48E+04 4.15E+04 2.53E+05 4.89E+02 3.34E+04 2.06E+07 0.00217 Cs-134 3.13E+02 2.90E+02 1.77E+03 3.41E+00 2.33E+02 4.32E+08 0.00000 Cs-137 2.13E+06 1.98E+06 1.21E+07 2.33E+04 1.59E+06 5.66E+08 0.00377 Eu-152 1.38E+04 1.28E+04 7.78E+04 1.50E+02 1.03E+04 5.26E+09 0.00000 Eu-154 1.88E+03 1.74E+03 1.06E+04 2.05E+01 1.40E+03 4.58E+09 0.00000 Mean BcSOF = 0.0082 The mean BcSOF for Containment was 0.0082, which equates to a dose for the survey unit of 0.2058 mrem/yr.

Table 12 - Survey Unit #02112 Statistical Summary Using Auxiliary Building BcDCGLPN ROC Mean Conc Median Max Conc Min Conc STD BcDCGLPN Nuclide Mean SOF (BcSOFPN)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

H-3 4.01E+06 3.62E+06 2.12E+07 6.41E+04 2.72E+06 3.99E+09 0.0010 Co-60 1.58E+05 1.42E+05 8.35E+05 2.52E+03 1.07E+05 8.82E+07 0.0018 Ni-63 6.97E+07 6.30E+07 3.69E+08 1.11E+06 4.73E+07 6.79E+10 0.0010 Sr-90 4.78E+04 4.32E+04 2.53E+05 7.64E+02 3.24E+04 2.41E+07 0.0020 Cs-134 3.34E+02 3.02E+02 1.77E+03 5.34E+00 2.27E+02 3.28E+08 0.0000 Cs-137 2.28E+06 2.06E+06 1.21E+07 3.64E+04 1.55E+06 6.17E+08 0.0037 Eu-152 1.47E+04 1.33E+04 7.78E+04 2.35E+02 9.97E+03 3.29E+08 0.0000 Eu-154 2.00E+03 1.81E+03 1.06E+04 3.20E+01 1.36E+03 2.33E+08 0.0000 Mean BcSOF = 0.0095 The mean BcSOF for the Auxiliary Building was 0.0095, which equates to a dose for the survey unit of 0.2386 mrem/yr.

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[30]

Table 13 - Survey Unit #02112 Statistical Summary Using Turbine Building BcDCGLPN ROC Mean Conc Median Max Conc Min Conc STD BcDCGLPN Nuclide Mean SOF (BcSOFPN)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

H-3 8.07E+04 5.91E+04 2.00E+05 3.94E+04 4.60E+04 3.23E+09 0.0000 Co-60 3.18E+03 2.33E+03 7.87E+03 1.55E+03 1.81E+03 1.76E+09 0.0000 Ni-63 1.40E+06 1.03E+06 3.48E+06 6.85E+05 7.99E+05 5.48E+10 0.0000 Sr-90 9.63E+02 7.05E+02 2.39E+03 4.70E+02 5.48E+02 1.94E+07 0.0000 Cs-134 6.73E+00 4.93E+00 1.67E+01 3.28E+00 3.83E+00 4.00E+08 0.0000 Cs-137 4.59E+04 3.36E+04 1.14E+05 2.24E+04 2.61E+04 5.29E+08 0.0001 Eu-152 2.96E+02 2.17E+02 7.33E+02 1.44E+02 1.69E+02 4.06E+09 0.0000 Eu-154 9.88E+04 2.96E+01 2.37E+06 1.97E+01 4.84E+05 3.58E+09 0.0000 Mean BcSOF = 0.0002 The mean SOF for the Turbine Building was 0.0002, which equates to a dose for the survey unit of 0.0054 mrem/yr.

No measurement exceeded the OpDCGLPN for Containment penetrations. Consequently, no adjustment to the mean BcSOF was required to account for dose from elevated measurements.

8.

QUALITY CONTROL In compliance with ZS-LT-01, replicate measurements were performed on 5% of the survey locations chosen at random. Twenty (20) replicate measurements were taken, which equates to 5.4% of the total number of measurements and satisfies the requirement.

The data was evaluated using USNRC acceptance criteria specified in Inspection Procedure No. 84750, Radioactive Waste Treatment, and Effluent and Environmental Monitoring (Reference 16). There was acceptable agreement between field replicate results. Refer to Attachment 4 for data and quality control analysis results.

9.

INVESTIGATIONS AND RESULTS No investigations were performed during the performance or analyses of the FSS.

10.

REMEDIATION AND RESULTS No radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS.

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[31]

11.

CHANGES FROM THE FINAL STATUS SURVEY PLAN There were no addendums to the FSS plan.

12.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with ZionSolutions procedure ZS-LT-300-001-004, Final Status Survey Data Assessment for completeness and consistency. Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly classified.

The analytical results of all samples were less than a SOF of one. Although MARSSIM states that the Sign Test need not be performed in the instance that no measurements surpass the DCGL, the test was conducted to demonstrate coherence to the statistical principles of the DQO process. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results clearly demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

The preliminary data review consisted of calculating basic statistical quantities (e.g.,

mean, median, standard deviation). All data was considered valid including negative values, zeros, values reported below the MDC, and values with uncertainties greater than two standard deviations. The mean and median values for each ROC were well below the respective Operational DCGLs. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.

13.

ANOMALIES No anomalies were observed during the performance or analyses of the survey.

14.

CONCLUSION Survey Unit S1-02112 has met the DQOs of the FSS plan. The ALARA criteria as specified in Chapter 4 of the LTP were achieved. The EMC is not applicable to structural surfaces and remediation was successfully implemented.

All identified ROC were used for statistical testing to determine the adequacy of the survey unit for FSS. Evaluation of the data shows that none of the ROC concentration values exceed the Operational DCGL or any investigational levels; therefore, in accordance with the LTP Section 5.10, the survey unit meets the release criterion.

The sample data passed the Sign Test. The null hypothesis was rejected. The

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[32]

Retrospective Power Curve (see Attachment 5) showed that adequate power was achieved.

The survey unit was properly classified as Class 1.

LTP Chapter 6, section 6.4.5 requires that the dose from a penetration be added to each Basement that the penetration interfaces with. The penetrations in Unit 2 Containment interface both with the Auxiliary Building and with the Turbine Building. LTP Chapter 5, section 5.5.5 also requires that the dose from elevated measurements be added to the mean dose for the survey unit affected. No penetration that interfaced with either the Auxiliary Building or Turbine Building had elevated measurements, consequently no adjustment was required for the BcSOF for the these buildings.

The mean BcSOFPN for the Unit 2 Containment Penetrations is 0.0082 based on the average concentration of the ROCs in samples used for non-parametric statistical sampling after adjustment for the presence of elevated measurements. The dose contribution from the Unit 2 Containment penetrations is 0.2058 mrem/yr TEDE.

The mean BcSOFPN for the Auxiliary Building Penetrations is 0.0095 based on the average concentration of the ROCs in samples used for non-parametric statistical sampling after adjustment for the presence of elevated measurements. The dose contribution from the Auxiliary Building penetrations is 0.2386 mrem/yr TEDE.

The adjusted mean BcSOFPN for the Turbine Building Penetrations is 0.0002 based on the average concentration of the ROCs in samples used for non-parametric statistical sampling. There were no elevated measurements. The dose contribution from the Auxiliary Building penetrations is 0.0054 mrem/yr TEDE.

Survey Unit #S1-02112AF is acceptable for unrestricted release.

15.

REFERENCES

1. ZionSolutions procedure ZS-LT-300-001-005, Revision 5, Final Status Survey Data Reporting
2. Zion Station Restoration Project License Termination Plan, Revision 2
3. ZionSolutions procedure ZS-LT-300-001-001, Revision 6, Final Status Survey Package Development
4. NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM)
5. ZionSolutions TSD 14-016, Revision Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State
6. ZionSolutions procedure ZS-LT-300-001-002, Revision 6, Survey Unit Classification
7. Zion Station Historical Site Assessment (HSA)

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[33]

8. ZionSolutions TSD 14-028, Revision 0, Radiological Characterization Report
9. ZionSolutions TSD 11-001, Revision 1 Potential Radionuclides of Concern during the Decommissioning of Zion Station
10. ZionSolutions TSD 17-004, Revision 2, Operational Derived Concentration Guideline Levels for Final Status Survey
11. ZionSolutions TSD 14-019, Revision 2, Radionuclides of Concern for Soil and Basement Fill Model Source Terms
12. ZionSolutions ZS-LT-01, Revision 6, Quality Assurance Project Plan (for Characterization and FSS), (QAPP)
13. ZionSolutions procedure ZS-LT-300-001-003, Revision 6, Isolation and Control for Final Status Survey
14. ZionSolutions procedure ZS-LT-300-001-006, Revision 5, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors
15. ZionSolutions procedure ZS-LT-300-001-004, Revision 7, Final Status Survey Data Assessment
16. U.S. NRC Inspection Procedure No. 84750, Radioactive Waste Treatment, and Effluent and Environmental Monitoring
16.

ATTACHMENTS

- Figures and Maps

- Sample Data

- Sign Test

- QC Data

- Graphical Representations

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[34]

ATTACHMENT 1 FIGURES AND MAPS

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[35]

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[36]

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[37]

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[38]

ATTACHMENT 2 SAMPLE DATA

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[39]

Unit 2 Penetration Summary Penetration Description Diameter Length Area Accessed From Measurement #s By Direct Scan SOF Requires Grouting (in)

(ft)

(m2)

(side)

OpDCGLPN BcDCGLPN OpDCGLB CTMT P201 Fire Protection 10 5

1.22 U2 Containment 1

thru 4

0.685 0.047 4.895 Yes P203 Spare 6

5 0.73 Auxiliary 15 thru 19 0.102 0.007 0.730 No P204 Boron Injection Tank to Cold Legs 8

5 0.97 U2 Containment 86 thru 90 0.392 0.027 2.805 Yes P219 Component Cooling Water Supply Header to RCPs 12 5

1.46 U2 Containment 57 thru 60 0.230 0.016 1.641 Yes P223 RC Pumps to Comp Cooling Pump Suction 12 5

1.46 U2 Containment 61 thru 64 0.310 0.021 2.214 Yes P235 Recirculating Sump Suction 23 51 28.53 U2 Containment 218 thru 267 0.298 0.020 2.133 Yes P236 Cavity Flood Sump Suction 23 51 28.53 U2 Containment 168 thru 217 0.337 0.023 2.405 Yes P237 Cavity Flood Sump Suction 23 51 28.53 U2 Containment 118 thru 167 0.388 0.026 2.772 Yes P242 CTMT Sump Pump Discharge to Aux Bld Flr Drain Analysis Tank 6

5 0.73 U2 Containment 91 thru 95 0.320 0.022 2.285 Yes P243 RC Drain Pump Discharge to Hold-Up Tank 8

5 0.97 U2 Containment 70 thru 74 0.573 0.039 4.094 Yes P250 Spare 10 5

1.22 Auxiliary 5

thru 9

0.131 0.009 0.936 No P254 Containment Pressure 6

5 0.73 U2 Containment 28 thru 31 0.120 0.008 0.856 No P256 Filtered Vents 8

5 0.97 U2 Containment 81 thru 85 0.400 0.027 2.862 Yes P264 Spare 8

5 0.97 Auxiliary 20 thru 24 0.166 0.011 1.184 Yes P281 Non-Filtered Vents 8

5 0.97 U2 Containment 65 thru 69 0.431 0.029 3.080 Yes P286 Press Stem, Press Liq, RC Hot Leg Samples 10 5

1.22 U2 Containment 45 thru 48 0.489 0.033 3.498 Yes P287 Spare 10 5

1.22 Auxiliary 10 thru 14 0.185 0.013 1.320 Yes P288 Heating System Hot Water Supply 12 5

1.46 U2 Containment 53 thru 56 0.326 0.022 2.332 Yes P289 Heating System Hot Water Return 12 5

1.46 U2 Containment 49 thru 52 0.195 0.013 1.394 Yes P303 Spare 8

5 0.97 U2 Containment 75 thru 80 0.668 0.045 4.776 Yes P323 Recirculating Sump Suction 23 52 29.09 U2 Containment 268 thru 318 0.584 0.040 4.176 Yes P324 Recirculating Sump Suction 23 53 29.65 U2 Containment 319 thru 368 0.379 0.026 2.707 Yes P205 Main Steam 50 4

4.86 U2 Containment 38 thru 38 X

0.005 0.000 0.039 No P206 Main Steam 50 4

4.86 U2 Containment 39 thru 39 X

0.004 0.000 0.030 No P207 Main Steam 50 4

4.86 U2 Containment 43 thru 43 X

0.001 0.000 0.009 No P208 Main Steam 50 4

4.86 U2 Containment 99 thru 99 X

0.002 0.000 0.017 No P209 Feedwater 32 4

3.11 U2 Containment 37 thru 37 X

0.004 0.000 0.026 No P210 Feedwater 32 4

3.11 U2 Containment 110 thru 110 X

0.007 0.000 0.047 No P211 Feedwater 32 4

3.11 U2 Containment 41 thru 41 X

0.003 0.000 0.024 No P212 Feedwater 32 4

3.11 U2 Containment 102 thru 102 X

0.003 0.000 0.022 No P217 Reactor Coolant No. 1 Loop to Residual Heat Removal Pumps 28 5

3.41 U2 Containment 32 thru 32 X

0.003 0.000 0.021 No P218 Cavity Fill Pump 1A Discharge 18 5

2.19 Auxiliary 27 thru 27 X

0.016 0.001 0.115 No P220 Cavity Fill Pump 1B Discharge 18 5

2.19 Auxiliary 369 thru 369 X

0.003 0.000 0.024 No P221 Spare 28 5

3.41 Auxiliary 33 thru 33 X

0.002 0.000 0.017 No P222 28 5

3.41 U2 Containment 116 thru 116 X

0.003 0.000 0.023 No P266 RC Pump Seal Water Supply Lines 14 5

1.70 U2 Containment 96 thru 96 X

0.010 0.001 0.068 No P267 Spare 18 5

2.19 Auxiliary 25 thru 25 X

0.024 0.002 0.170 No P268 Aux Feedwater to Steam Gen 1C 14 5

1.70 U2 Containment 115 thru 115 X

0.010 0.001 0.074 No P269 Aux Feedwater to Steam Gen 1A 14 5

1.70 U2 Containment 97 thru 97 X

0.002 0.000 0.015 No

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[40]

Penetration Description Diameter Length Area Accessed From Measurement #s By Direct Scan SOF Requires Grouting (in)

(ft)

(m2)

(side)

OpDCGLP N

BcDCGLPN OpDCGLB CTMT P270 Refueling Cavity Drain to Purification Pump Suction 14 5

1.70 U2 Containment 114 thru 114 X

0.014 0.001 0.099 No P273 Spare 18 5

2.19 Auxiliary 26 thru 26 X

0.024 0.002 0.170 No P274 Aux Feedwater to Steam Gen 1D 14 5

1.70 U2 Containment 98 thru 98 X

0.002 0.000 0.015 No P290 Spare 28 5

3.41 Auxiliary 34 thru 34 X

0.003 0.000 0.021 No P291 Blowdown Steam Generator 1A 16 4

1.56 U2 Containment 113 thru 113 X

0.005 0.000 0.000 No P292 Blowdown Steam Generator 1A 16 4

1.56 U2 Containment 36 thru 36 X

0.003 0.000 0.018 No P293 Blowdown Steam Generator 1C 16 4

1.56 U2 Containment 109 thru 109 X

0.003 0.000 0.019 No P294 Blowdown Steam Generator 1C 16 4

1.56 U2 Containment 108 thru 108 X

0.002 0.000 0.014 No P295 Blowdown Steam Generator 1A 14 4

1.36 U2 Containment 112 thru 112 X

0.003 0.000 0.000 No P296 Blowdown Steam Generator 1C 14 4

1.36 U2 Containment 44 thru 44 X

0.002 0.000 0.013 No P297 Blowdown Steam Generator 1D 14 4

1.36 U2 Containment 105 thru 105 X

0.002 0.000 0.015 No P298 Blowdown Steam Generator 1B 14 4

1.36 U2 Containment 103 thru 103 X

0.002 0.000 0.016 No P304 SIM to Aux F.S. Pumps 24 5

2.92 U2 Containment 117 thru 117 X

0.011 0.001 0.079 No P305 Residual Heat Exchanger to RC Loop Hot Legs 18 5

2.19 Auxiliary 35 thru 35 X

0.003 0.000 0.023 No P312 Steam Generator Blowdown Sample 16 4

1.56 U2 Containment 111 thru 111 X

0.003 0.000 0.020 No P313 Steam Generator Blowdown Sample 16 4

1.56 U2 Containment 104 thru 104 X

0.002 0.000 0.015 No P315 Blowdown (Steam Generator 1D) 16 4

1.56 U2 Containment 42 thru 42 X

0.002 0.000 0.013 No P316 Blowdown (Steam Generator 1D) 16 4

1.56 U2 Containment 107 thru 107 X

0.004 0.000 0.025 No P317 Blowdown (Steam Generator 1B) 16 4

1.56 U2 Containment 101 thru 101 X

0.003 0.000 0.019 No P318 Blowdown (Steam Generator 1B) 16 4

1.56 U2 Containment 100 thru 100 X

0.003 0.000 0.021 No P327 Steam to Aux FW Pumps 16 4

1.56 U2 Containment 40 thru 40 X

0.003 0.000 0.021 No P328 Steam to Aux FW Pumps 16 4

1.56 U2 Containment 106 thru 106 X

0.002 0.000 0.017 No

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[41]

Penetration NaI* Survey Data Assessment No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 1

P201 Position #1 4

1.30E+07 H-3 1.76 2.12E+07 2.33E+08 0.0911 0.6849 3.42E+09 0.0062 0.0466 3.25E+07 0.6531 4.8948 Co-60 0.06431 8.35E+05 1.54E+08 0.0054 2.26E+09 0.0004 2.15E+07 0.0388 Ni-63 442 3.69E+08 3.93E+09 0.0939 5.78E+10 0.0064 5.50E+08 0.6711 Sr-90 0.021 2.53E+05 1.40E+06 0.1809 2.06E+07 0.0123 1.96E+05 1.2921 Cs-134 0.00014 1.77E+03 2.94E+07 0.0001 4.32E+08 0.0000 4.12E+06 0.0004 Cs-137 0.92875 1.21E+07 3.85E+07 0.3132 5.66E+08 0.0213 5.39E+06 2.2375 Eu-152 0.00599 7.78E+04 3.58E+08 0.0002 5.26E+09 0.0000 5.00E+07 0.0016 Eu-154 0.00082 1.06E+04 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0002 2

P201 Position #2 3

1.79E+06 H-3 1.76 2.93E+06 2.33E+08 0.0126 0.0947 3.42E+09 0.0009 0.0064 3.25E+07 0.0903 0.6765 Co-60 0.06431 1.15E+05 1.54E+08 0.0007 2.26E+09 0.0001 2.15E+07 0.0054 Ni-63 442 5.10E+07 3.93E+09 0.0130 5.78E+10 0.0009 5.50E+08 0.0927 Sr-90 0.021 3.50E+04 1.40E+06 0.0250 2.06E+07 0.0017 1.96E+05 0.1786 Cs-134 0.00014 2.45E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.67E+06 3.85E+07 0.0433 5.66E+08 0.0029 5.39E+06 0.3092 Eu-152 0.00599 1.08E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.47E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 3

P201 Position #3 2

1.14E+06 H-3 1.76 1.87E+06 2.33E+08 0.0080 0.0603 3.42E+09 0.0005 0.0041 3.25E+07 0.0575 0.4312 Co-60 0.06431 7.36E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0034 Ni-63 442 3.25E+07 3.93E+09 0.0083 5.78E+10 0.0006 5.50E+08 0.0591 Sr-90 0.021 2.23E+04 1.40E+06 0.0159 2.06E+07 0.0011 1.96E+05 0.1138 Cs-134 0.00014 1.56E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.06E+06 3.85E+07 0.0276 5.66E+08 0.0019 5.39E+06 0.1971 Eu-152 0.00599 6.86E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 9.35E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 4

P201 Position #4 1

1.14E+06 H-3 1.76 1.87E+06 2.33E+08 0.0080 0.0602 3.42E+09 0.0005 0.0041 3.25E+07 0.0574 0.4302 Co-60 0.06431 7.34E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0034 Ni-63 442 3.24E+07 3.93E+09 0.0083 5.78E+10 0.0006 5.50E+08 0.0590 Sr-90 0.021 2.23E+04 1.40E+06 0.0159 2.06E+07 0.0011 1.96E+05 0.1136 Cs-134 0.00014 1.55E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.06E+06 3.85E+07 0.0275 5.66E+08 0.0019 5.39E+06 0.1967 Eu-152 0.00599 6.84E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 9.33E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 5

P250 Position #1 0

1.00E+06 H-3 1.76 1.64E+06 2.33E+08 0.0070 0.0529 3.42E+09 0.0005 0.0036 3.25E+07 0.0505 0.3782 Co-60 0.06431 6.45E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0030 Ni-63 442 2.85E+07 3.93E+09 0.0073 5.78E+10 0.0005 5.50E+08 0.0519 Sr-90 0.021 1.96E+04 1.40E+06 0.0140 2.06E+07 0.0009 1.96E+05 0.0998 Cs-134 0.00014 1.37E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 9.32E+05 3.85E+07 0.0242 5.66E+08 0.0016 5.39E+06 0.1729 Eu-152 0.00599 6.01E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 8.20E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

  • Direct scans were accomplished with Ludlum ZnS(Ag) scintillation 43-93 and gas proportional 43-68 / detectors

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[42]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 6

P250 Position #2 1

1.06E+06 H-3 1.76 1.72E+06 2.33E+08 0.0074 0.0557 3.42E+09 0.0005 0.0038 3.25E+07 0.0531 0.3977 Co-60 0.06431 6.79E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0032 Ni-63 442 3.00E+07 3.93E+09 0.0076 5.78E+10 0.0005 5.50E+08 0.0545 Sr-90 0.021 2.06E+04 1.40E+06 0.0147 2.06E+07 0.0010 1.96E+05 0.1050 Cs-134 0.00014 1.44E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 9.80E+05 3.85E+07 0.0255 5.66E+08 0.0017 5.39E+06 0.1818 Eu-152 0.00599 6.33E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 8.63E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 7

P250 Position #3 2

1.13E+06 H-3 1.76 1.85E+06 2.33E+08 0.0079 0.0597 3.42E+09 0.0005 0.0041 3.25E+07 0.0569 0.4265 Co-60 0.06431 7.28E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0034 Ni-63 442 3.22E+07 3.93E+09 0.0082 5.78E+10 0.0006 5.50E+08 0.0585 Sr-90 0.021 2.21E+04 1.40E+06 0.0158 2.06E+07 0.0011 1.96E+05 0.1126 Cs-134 0.00014 1.54E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.05E+06 3.85E+07 0.0273 5.66E+08 0.0019 5.39E+06 0.1950 Eu-152 0.00599 6.78E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 9.25E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 8

P250 Position #4 3

1.30E+06 H-3 1.76 2.13E+06 2.33E+08 0.0091 0.0686 3.42E+09 0.0006 0.0047 3.25E+07 0.0654 0.4901 Co-60 0.06431 8.36E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0039 Ni-63 442 3.70E+07 3.93E+09 0.0094 5.78E+10 0.0006 5.50E+08 0.0672 Sr-90 0.021 2.54E+04 1.40E+06 0.0181 2.06E+07 0.0012 1.96E+05 0.1294 Cs-134 0.00014 1.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.21E+06 3.85E+07 0.0314 5.66E+08 0.0021 5.39E+06 0.2240 Eu-152 0.00599 7.79E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.06E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 9

P250 Position #5 4

2.48E+06 H-3 1.76 4.06E+06 2.33E+08 0.0174 0.1310 3.42E+09 0.0012 0.0089 3.25E+07 0.1249 0.9362 Co-60 0.06431 1.60E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0074 Ni-63 442 7.06E+07 3.93E+09 0.0180 5.78E+10 0.0012 5.50E+08 0.1283 Sr-90 0.021 4.84E+04 1.40E+06 0.0346 2.06E+07 0.0024 1.96E+05 0.2471 Cs-134 0.00014 3.38E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.31E+06 3.85E+07 0.0599 5.66E+08 0.0041 5.39E+06 0.4279 Eu-152 0.00599 1.49E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.03E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 10 P287 Position #1 1

7.61E+05 H-3 1.76 1.24E+06 2.33E+08 0.0053 0.0401 3.42E+09 0.0004 0.0027 3.25E+07 0.0383 0.2868 Co-60 0.06431 4.89E+04 1.54E+08 0.0003 2.26E+09 0.0000 2.15E+07 0.0023 Ni-63 442 2.16E+07 3.93E+09 0.0055 5.78E+10 0.0004 5.50E+08 0.0393 Sr-90 0.021 1.48E+04 1.40E+06 0.0106 2.06E+07 0.0007 1.96E+05 0.0757 Cs-134 0.00014 1.04E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.07E+05 3.85E+07 0.0184 5.66E+08 0.0012 5.39E+06 0.1311 Eu-152 0.00599 4.56E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 6.22E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 11 P287 Position #2 2

9.48E+05 H-3 1.76 1.55E+06 2.33E+08 0.0067 0.0500 3.42E+09 0.0005 0.0034 3.25E+07 0.0477 0.3573 Co-60 0.06431 6.10E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0028 Ni-63 442 2.69E+07 3.93E+09 0.0069 5.78E+10 0.0005 5.50E+08 0.0490 Sr-90 0.021 1.85E+04 1.40E+06 0.0132 2.06E+07 0.0009 1.96E+05 0.0943 Cs-134 0.00014 1.29E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 8.80E+05 3.85E+07 0.0229 5.66E+08 0.0016 5.39E+06 0.1633 Eu-152 0.00599 5.68E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.75E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[43]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 12 P287 Position #3 3

1.08E+06 H-3 1.76 1.77E+06 2.33E+08 0.0076 0.0571 3.42E+09 0.0005 0.0039 3.25E+07 0.0544 0.4079 Co-60 0.06431 6.96E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0032 Ni-63 442 3.08E+07 3.93E+09 0.0078 5.78E+10 0.0005 5.50E+08 0.0559 Sr-90 0.021 2.11E+04 1.40E+06 0.0151 2.06E+07 0.0010 1.96E+05 0.1077 Cs-134 0.00014 1.47E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.00E+06 3.85E+07 0.0261 5.66E+08 0.0018 5.39E+06 0.1865 Eu-152 0.00599 6.49E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 8.85E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 13 P287 Position #4 4

1.32E+06 H-3 1.76 2.16E+06 2.33E+08 0.0093 0.0696 3.42E+09 0.0006 0.0047 3.25E+07 0.0663 0.4971 Co-60 0.06431 8.48E+04 1.54E+08 0.0006 2.26E+09 0.0000 2.15E+07 0.0039 Ni-63 442 3.75E+07 3.93E+09 0.0095 5.78E+10 0.0006 5.50E+08 0.0682 Sr-90 0.021 2.57E+04 1.40E+06 0.0184 2.06E+07 0.0012 1.96E+05 0.1312 Cs-134 0.00014 1.80E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.22E+06 3.85E+07 0.0318 5.66E+08 0.0022 5.39E+06 0.2273 Eu-152 0.00599 7.91E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.08E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 14 P287 Position #5 5

3.50E+06 H-3 1.76 5.72E+06 2.33E+08 0.0246 0.1847 3.42E+09 0.0017 0.0126 3.25E+07 0.1761 1.3199 Co-60 0.06431 2.25E+05 1.54E+08 0.0015 2.26E+09 0.0001 2.15E+07 0.0105 Ni-63 442 9.95E+07 3.93E+09 0.0253 5.78E+10 0.0017 5.50E+08 0.1809 Sr-90 0.021 6.83E+04 1.40E+06 0.0488 2.06E+07 0.0033 1.96E+05 0.3484 Cs-134 0.00014 4.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.25E+06 3.85E+07 0.0845 5.66E+08 0.0057 5.39E+06 0.6033 Eu-152 0.00599 2.10E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.86E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 15 P203 Position #1 0

1.71E+06 H-3 1.76 2.79E+06 2.33E+08 0.0120 0.0902 3.42E+09 0.0008 0.0061 3.25E+07 0.0860 0.6444 Co-60 0.06431 1.10E+05 1.54E+08 0.0007 2.26E+09 0.0000 2.15E+07 0.0051 Ni-63 442 4.86E+07 3.93E+09 0.0124 5.78E+10 0.0008 5.50E+08 0.0883 Sr-90 0.021 3.33E+04 1.40E+06 0.0238 2.06E+07 0.0016 1.96E+05 0.1701 Cs-134 0.00014 2.33E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.59E+06 3.85E+07 0.0412 5.66E+08 0.0028 5.39E+06 0.2946 Eu-152 0.00599 1.02E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.40E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 16 P203 Position #2 1

9.95E+05 H-3 1.76 1.63E+06 2.33E+08 0.0070 0.0525 3.42E+09 0.0005 0.0036 3.25E+07 0.0500 0.3750 Co-60 0.06431 6.40E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0030 Ni-63 442 2.83E+07 3.93E+09 0.0072 5.78E+10 0.0005 5.50E+08 0.0514 Sr-90 0.021 1.94E+04 1.40E+06 0.0139 2.06E+07 0.0009 1.96E+05 0.0990 Cs-134 0.00014 1.36E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 9.24E+05 3.85E+07 0.0240 5.66E+08 0.0016 5.39E+06 0.1714 Eu-152 0.00599 5.96E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 8.13E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 17 P203 Position #3 2

8.85E+05 H-3 1.76 1.45E+06 2.33E+08 0.0062 0.0467 3.42E+09 0.0004 0.0032 3.25E+07 0.0445 0.3337 Co-60 0.06431 5.69E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0026 Ni-63 442 2.52E+07 3.93E+09 0.0064 5.78E+10 0.0004 5.50E+08 0.0457 Sr-90 0.021 1.73E+04 1.40E+06 0.0123 2.06E+07 0.0008 1.96E+05 0.0881 Cs-134 0.00014 1.21E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 8.22E+05 3.85E+07 0.0214 5.66E+08 0.0015 5.39E+06 0.1525 Eu-152 0.00599 5.31E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.24E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[44]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 18 P203 Position #4 3

7.83E+05 H-3 1.76 1.28E+06 2.33E+08 0.0055 0.0413 3.42E+09 0.0004 0.0028 3.25E+07 0.0394 0.2951 Co-60 0.06431 5.03E+04 1.54E+08 0.0003 2.26E+09 0.0000 2.15E+07 0.0023 Ni-63 442 2.22E+07 3.93E+09 0.0057 5.78E+10 0.0004 5.50E+08 0.0405 Sr-90 0.021 1.53E+04 1.40E+06 0.0109 2.06E+07 0.0007 1.96E+05 0.0779 Cs-134 0.00014 1.07E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.27E+05 3.85E+07 0.0189 5.66E+08 0.0013 5.39E+06 0.1349 Eu-152 0.00599 4.69E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 6.40E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 19 P203 Position #5 4

1.94E+06 H-3 1.76 3.16E+06 2.33E+08 0.0136 0.1021 3.42E+09 0.0009 0.0069 3.25E+07 0.0974 0.7297 Co-60 0.06431 1.24E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0058 Ni-63 442 5.50E+07 3.93E+09 0.0140 5.78E+10 0.0010 5.50E+08 0.1000 Sr-90 0.021 3.78E+04 1.40E+06 0.0270 2.06E+07 0.0018 1.96E+05 0.1926 Cs-134 0.00014 2.64E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.80E+06 3.85E+07 0.0467 5.66E+08 0.0032 5.39E+06 0.3336 Eu-152 0.00599 1.16E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.58E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 20 P264 Position #1 0

1.11E+06 H-3 1.76 1.82E+06 2.33E+08 0.0078 0.0588 3.42E+09 0.0005 0.0040 3.25E+07 0.0560 0.4199 Co-60 0.06431 7.16E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0033 Ni-63 442 3.17E+07 3.93E+09 0.0081 5.78E+10 0.0005 5.50E+08 0.0576 Sr-90 0.021 2.17E+04 1.40E+06 0.0155 2.06E+07 0.0011 1.96E+05 0.1108 Cs-134 0.00014 1.52E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.03E+06 3.85E+07 0.0269 5.66E+08 0.0018 5.39E+06 0.1919 Eu-152 0.00599 6.68E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 9.11E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 21 P264 Position #2 1

1.09E+06 H-3 1.76 1.78E+06 2.33E+08 0.0077 0.0576 3.42E+09 0.0005 0.0039 3.25E+07 0.0549 0.4114 Co-60 0.06431 7.02E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0033 Ni-63 442 3.10E+07 3.93E+09 0.0079 5.78E+10 0.0005 5.50E+08 0.0564 Sr-90 0.021 2.13E+04 1.40E+06 0.0152 2.06E+07 0.0010 1.96E+05 0.1086 Cs-134 0.00014 1.49E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.01E+06 3.85E+07 0.0263 5.66E+08 0.0018 5.39E+06 0.1881 Eu-152 0.00599 6.54E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 8.92E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 22 P264 Position #3 2

1.01E+06 H-3 1.76 1.65E+06 2.33E+08 0.0071 0.0532 3.42E+09 0.0005 0.0036 3.25E+07 0.0508 0.3806 Co-60 0.06431 6.49E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0030 Ni-63 442 2.87E+07 3.93E+09 0.0073 5.78E+10 0.0005 5.50E+08 0.0522 Sr-90 0.021 1.97E+04 1.40E+06 0.0141 2.06E+07 0.0010 1.96E+05 0.1005 Cs-134 0.00014 1.38E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 9.38E+05 3.85E+07 0.0244 5.66E+08 0.0017 5.39E+06 0.1740 Eu-152 0.00599 6.05E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 8.25E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 23 P264 Position #4 3

1.04E+06 H-3 1.76 1.70E+06 2.33E+08 0.0073 0.0547 3.42E+09 0.0005 0.0037 3.25E+07 0.0522 0.3912 Co-60 0.06431 6.67E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0031 Ni-63 442 2.95E+07 3.93E+09 0.0075 5.78E+10 0.0005 5.50E+08 0.0536 Sr-90 0.021 2.02E+04 1.40E+06 0.0145 2.06E+07 0.0010 1.96E+05 0.1033 Cs-134 0.00014 1.41E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 9.64E+05 3.85E+07 0.0250 5.66E+08 0.0017 5.39E+06 0.1788 Eu-152 0.00599 6.22E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 8.48E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[45]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 24 P264 Position #5 4

3.14E+06 H-3 1.76 5.13E+06 2.33E+08 0.0220 0.1656 3.42E+09 0.0015 0.0113 3.25E+07 0.1579 1.1838 Co-60 0.06431 2.02E+05 1.54E+08 0.0013 2.26E+09 0.0001 2.15E+07 0.0094 Ni-63 442 8.93E+07 3.93E+09 0.0227 5.78E+10 0.0015 5.50E+08 0.1623 Sr-90 0.021 6.12E+04 1.40E+06 0.0437 2.06E+07 0.0030 1.96E+05 0.3125 Cs-134 0.00014 4.28E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.92E+06 3.85E+07 0.0758 5.66E+08 0.0052 5.39E+06 0.5411 Eu-152 0.00599 1.88E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.57E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 25 P267 By Direct Scan N/A 7.24E+04 H-3 1.76 1.18E+05 2.33E+08 0.0005 0.0038 3.42E+09 0.0000 0.0003 3.25E+07 0.0036 0.0273 Co-60 0.06431 4.66E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 2.06E+06 3.93E+09 0.0005 5.78E+10 0.0000 5.50E+08 0.0037 Sr-90 0.021 1.41E+03 1.40E+06 0.0010 2.06E+07 0.0001 1.96E+05 0.0072 Cs-134 0.00014 9.87E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 6.73E+04 3.85E+07 0.0017 5.66E+08 0.0001 5.39E+06 0.0125 Eu-152 0.00599 4.34E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 5.92E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 26 P273 By Direct Scan N/A 4.51E+05 H-3 1.76 7.37E+05 2.33E+08 0.0032 0.0238 3.42E+09 0.0002 0.0016 3.25E+07 0.0227 0.1700 Co-60 0.06431 2.90E+04 1.54E+08 0.0002 2.26E+09 0.0000 2.15E+07 0.0013 Ni-63 442 1.28E+07 3.93E+09 0.0033 5.78E+10 0.0002 5.50E+08 0.0233 Sr-90 0.021 8.80E+03 1.40E+06 0.0063 2.06E+07 0.0004 1.96E+05 0.0449 Cs-134 0.00014 6.15E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 4.19E+05 3.85E+07 0.0109 5.66E+08 0.0007 5.39E+06 0.0777 Eu-152 0.00599 2.70E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 3.69E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 27 P218 By Direct Scan N/A 3.05E+05 H-3 1.76 4.98E+05 2.33E+08 0.0021 0.0161 3.42E+09 0.0001 0.0011 3.25E+07 0.0153 0.1149 Co-60 0.06431 1.96E+04 1.54E+08 0.0001 2.26E+09 0.0000 2.15E+07 0.0009 Ni-63 442 8.67E+06 3.93E+09 0.0022 5.78E+10 0.0001 5.50E+08 0.0158 Sr-90 0.021 5.95E+03 1.40E+06 0.0042 2.06E+07 0.0003 1.96E+05 0.0303 Cs-134 0.00014 4.15E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 2.83E+05 3.85E+07 0.0074 5.66E+08 0.0005 5.39E+06 0.0525 Eu-152 0.00599 1.83E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 2.49E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 28 P254 Position #1 0

2.27E+06 H-3 1.76 3.71E+06 2.33E+08 0.0159 0.1197 3.42E+09 0.0011 0.0081 3.25E+07 0.1142 0.8558 Co-60 0.06431 1.46E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0068 Ni-63 442 6.45E+07 3.93E+09 0.0164 5.78E+10 0.0011 5.50E+08 0.1173 Sr-90 0.021 4.43E+04 1.40E+06 0.0316 2.06E+07 0.0021 1.96E+05 0.2259 Cs-134 0.00014 3.09E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.11E+06 3.85E+07 0.0548 5.66E+08 0.0037 5.39E+06 0.3912 Eu-152 0.00599 1.36E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.86E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 29 P254 Position #2 1

8.56E+05 H-3 1.76 1.40E+06 2.33E+08 0.0060 0.0451 3.42E+09 0.0004 0.0031 3.25E+07 0.0431 0.3227 Co-60 0.06431 5.50E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0026 Ni-63 442 2.43E+07 3.93E+09 0.0062 5.78E+10 0.0004 5.50E+08 0.0442 Sr-90 0.021 1.67E+04 1.40E+06 0.0119 2.06E+07 0.0008 1.96E+05 0.0852 Cs-134 0.00014 1.17E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.95E+05 3.85E+07 0.0206 5.66E+08 0.0014 5.39E+06 0.1475 Eu-152 0.00599 5.13E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.00E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[46]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 30 P254 Position #3 2

7.90E+05 H-3 1.76 1.29E+06 2.33E+08 0.0055 0.0416 3.42E+09 0.0004 0.0028 3.25E+07 0.0397 0.2976 Co-60 0.06431 5.08E+04 1.54E+08 0.0003 2.26E+09 0.0000 2.15E+07 0.0024 Ni-63 442 2.24E+07 3.93E+09 0.0057 5.78E+10 0.0004 5.50E+08 0.0408 Sr-90 0.021 1.54E+04 1.40E+06 0.0110 2.06E+07 0.0007 1.96E+05 0.0786 Cs-134 0.00014 1.08E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.33E+05 3.85E+07 0.0190 5.66E+08 0.0013 5.39E+06 0.1360 Eu-152 0.00599 4.73E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 6.45E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 31 P254 Position #4 3

8.19E+05 H-3 1.76 1.34E+06 2.33E+08 0.0057 0.0432 3.42E+09 0.0004 0.0029 3.25E+07 0.0412 0.3086 Co-60 0.06431 5.27E+04 1.54E+08 0.0003 2.26E+09 0.0000 2.15E+07 0.0024 Ni-63 442 2.33E+07 3.93E+09 0.0059 5.78E+10 0.0004 5.50E+08 0.0423 Sr-90 0.021 1.60E+04 1.40E+06 0.0114 2.06E+07 0.0008 1.96E+05 0.0815 Cs-134 0.00014 1.12E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.60E+05 3.85E+07 0.0198 5.66E+08 0.0013 5.39E+06 0.1411 Eu-152 0.00599 4.91E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 6.69E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 32 P217 By Direct Scan N/A 5.69E+04 H-3 1.76 9.31E+04 2.33E+08 0.0004 0.0030 3.42E+09 0.0000 0.0002 3.25E+07 0.0029 0.0215 Co-60 0.06431 3.66E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.62E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0029 Sr-90 0.021 1.11E+03 1.40E+06 0.0008 2.06E+07 0.0001 1.96E+05 0.0057 Cs-134 0.00014 7.76E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 5.29E+04 3.85E+07 0.0014 5.66E+08 0.0001 5.39E+06 0.0098 Eu-152 0.00599 3.41E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.65E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 33 P221 By Direct Scan N/A 4.41E+04 H-3 1.76 7.20E+04 2.33E+08 0.0003 0.0023 3.42E+09 0.0000 0.0002 3.25E+07 0.0022 0.0166 Co-60 0.06431 2.83E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.25E+06 3.93E+09 0.0003 5.78E+10 0.0000 5.50E+08 0.0023 Sr-90 0.021 8.59E+02 1.40E+06 0.0006 2.06E+07 0.0000 1.96E+05 0.0044 Cs-134 0.00014 6.00E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 4.09E+04 3.85E+07 0.0011 5.66E+08 0.0001 5.39E+06 0.0076 Eu-152 0.00599 2.64E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 3.60E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 34 P290 By Direct Scan N/A 5.62E+04 H-3 1.76 9.18E+04 2.33E+08 0.0004 0.0030 3.42E+09 0.0000 0.0002 3.25E+07 0.0028 0.0212 Co-60 0.06431 3.61E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.60E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0029 Sr-90 0.021 1.10E+03 1.40E+06 0.0008 2.06E+07 0.0001 1.96E+05 0.0056 Cs-134 0.00014 7.65E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 5.22E+04 3.85E+07 0.0014 5.66E+08 0.0001 5.39E+06 0.0097 Eu-152 0.00599 3.37E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.59E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 35 P305 By Direct Scan N/A 6.00E+04 H-3 1.76 9.80E+04 2.33E+08 0.0004 0.0032 3.42E+09 0.0000 0.0002 3.25E+07 0.0030 0.0226 Co-60 0.06431 3.86E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.70E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0031 Sr-90 0.021 1.17E+03 1.40E+06 0.0008 2.06E+07 0.0001 1.96E+05 0.0060 Cs-134 0.00014 8.17E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 5.57E+04 3.85E+07 0.0014 5.66E+08 0.0001 5.39E+06 0.0103 Eu-152 0.00599 3.59E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.90E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[47]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 36 P292 By Direct Scan N/A 4.91E+04 H-3 1.76 8.02E+04 2.33E+08 0.0003 0.0026 3.42E+09 0.0000 0.0002 3.25E+07 0.0025 0.0185 Co-60 0.06431 3.15E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.39E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0025 Sr-90 0.021 9.57E+02 1.40E+06 0.0007 2.06E+07 0.0000 1.96E+05 0.0049 Cs-134 0.00014 6.68E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 4.56E+04 3.85E+07 0.0012 5.66E+08 0.0001 5.39E+06 0.0085 Eu-152 0.00599 2.94E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.01E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 37 P209 By Direct Scan N/A 6.87E+04 H-3 1.76 1.12E+05 2.33E+08 0.0005 0.0036 3.42E+09 0.0000 0.0002 3.25E+07 0.0035 0.0259 Co-60 0.06431 4.42E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.95E+06 3.93E+09 0.0005 5.78E+10 0.0000 5.50E+08 0.0036 Sr-90 0.021 1.34E+03 1.40E+06 0.0010 2.06E+07 0.0001 1.96E+05 0.0068 Cs-134 0.00014 9.37E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 6.38E+04 3.85E+07 0.0017 5.66E+08 0.0001 5.39E+06 0.0118 Eu-152 0.00599 4.12E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 5.62E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 38 P205 By Direct Scan 1

1.03E+05 H-3 1.76 1.68E+05 2.33E+08 0.0007 0.0054 3.42E+09 0.0000 0.0004 3.25E+07 0.0052 0.0388 Co-60 0.06431 6.61E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0003 Ni-63 442 2.92E+06 3.93E+09 0.0007 5.78E+10 0.0001 5.50E+08 0.0053 Sr-90 0.021 2.01E+03 1.40E+06 0.0014 2.06E+07 0.0001 1.96E+05 0.0102 Cs-134 0.00014 1.40E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 9.55E+04 3.85E+07 0.0025 5.66E+08 0.0002 5.39E+06 0.0177 Eu-152 0.00599 6.16E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 8.40E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 39 P206 By Direct Scan 2

7.94E+04 H-3 1.76 1.30E+05 2.33E+08 0.0006 0.0042 3.42E+09 0.0000 0.0003 3.25E+07 0.0040 0.0299 Co-60 0.06431 5.11E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 2.26E+06 3.93E+09 0.0006 5.78E+10 0.0000 5.50E+08 0.0041 Sr-90 0.021 1.55E+03 1.40E+06 0.0011 2.06E+07 0.0001 1.96E+05 0.0079 Cs-134 0.00014 1.08E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.38E+04 3.85E+07 0.0019 5.66E+08 0.0001 5.39E+06 0.0137 Eu-152 0.00599 4.76E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 6.49E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 40 P327 By Direct Scan N/A 5.62E+04 H-3 1.76 9.18E+04 2.33E+08 0.0004 0.0030 3.42E+09 0.0000 0.0002 3.25E+07 0.0028 0.0212 Co-60 0.06431 3.61E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.60E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0029 Sr-90 0.021 1.10E+03 1.40E+06 0.0008 2.06E+07 0.0001 1.96E+05 0.0056 Cs-134 0.00014 7.65E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 5.22E+04 3.85E+07 0.0014 5.66E+08 0.0001 5.39E+06 0.0097 Eu-152 0.00599 3.37E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.59E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 41 P211 By Direct Scan N/A 6.41E+04 H-3 1.76 1.05E+05 2.33E+08 0.0004 0.0034 3.42E+09 0.0000 0.0002 3.25E+07 0.0032 0.0241 Co-60 0.06431 4.12E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.82E+06 3.93E+09 0.0005 5.78E+10 0.0000 5.50E+08 0.0033 Sr-90 0.021 1.25E+03 1.40E+06 0.0009 2.06E+07 0.0001 1.96E+05 0.0064 Cs-134 0.00014 8.73E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 5.95E+04 3.85E+07 0.0015 5.66E+08 0.0001 5.39E+06 0.0110 Eu-152 0.00599 3.84E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 5.24E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[48]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 42 P315 By Direct Scan N/A 3.45E+04 H-3 1.76 5.65E+04 2.33E+08 0.0002 0.0018 3.42E+09 0.0000 0.0001 3.25E+07 0.0017 0.0130 Co-60 0.06431 2.22E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 9.82E+05 3.93E+09 0.0002 5.78E+10 0.0000 5.50E+08 0.0018 Sr-90 0.021 6.74E+02 1.40E+06 0.0005 2.06E+07 0.0000 1.96E+05 0.0034 Cs-134 0.00014 4.71E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 3.21E+04 3.85E+07 0.0008 5.66E+08 0.0001 5.39E+06 0.0060 Eu-152 0.00599 2.07E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 2.82E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 43 P207 By Direct Scan N/A 2.51E+04 H-3 1.76 4.10E+04 2.33E+08 0.0002 0.0013 3.42E+09 0.0000 0.0001 3.25E+07 0.0013 0.0094 Co-60 0.06431 1.61E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 7.12E+05 3.93E+09 0.0002 5.78E+10 0.0000 5.50E+08 0.0013 Sr-90 0.021 4.89E+02 1.40E+06 0.0003 2.06E+07 0.0000 1.96E+05 0.0025 Cs-134 0.00014 3.41E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 2.33E+04 3.85E+07 0.0006 5.66E+08 0.0000 5.39E+06 0.0043 Eu-152 0.00599 1.50E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 2.05E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 44 P296 By Direct Scan N/A 3.40E+04 H-3 1.76 5.55E+04 2.33E+08 0.0002 0.0018 3.42E+09 0.0000 0.0001 3.25E+07 0.0017 0.0128 Co-60 0.06431 2.18E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 9.65E+05 3.93E+09 0.0002 5.78E+10 0.0000 5.50E+08 0.0018 Sr-90 0.021 6.62E+02 1.40E+06 0.0005 2.06E+07 0.0000 1.96E+05 0.0034 Cs-134 0.00014 4.63E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 3.15E+04 3.85E+07 0.0008 5.66E+08 0.0001 5.39E+06 0.0059 Eu-152 0.00599 2.04E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 2.78E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 45 P286 Position #1 4

9.28E+06 H-3 1.76 1.52E+07 2.33E+08 0.0651 0.4894 3.42E+09 0.0044 0.0333 3.25E+07 0.4667 3.4976 Co-60 0.06431 5.97E+05 1.54E+08 0.0039 2.26E+09 0.0003 2.15E+07 0.0278 Ni-63 442 2.64E+08 3.93E+09 0.0671 5.78E+10 0.0046 5.50E+08 0.4795 Sr-90 0.021 1.81E+05 1.40E+06 0.1293 2.06E+07 0.0088 1.96E+05 0.9233 Cs-134 0.00014 1.26E+03 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0003 Cs-137 0.92875 8.62E+06 3.85E+07 0.2238 5.66E+08 0.0152 5.39E+06 1.5988 Eu-152 0.00599 5.56E+04 3.58E+08 0.0002 5.26E+09 0.0000 5.00E+07 0.0011 Eu-154 0.00082 7.58E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0002 46 P286 Position #2 3

1.84E+06 H-3 1.76 3.00E+06 2.33E+08 0.0129 0.0969 3.42E+09 0.0009 0.0066 3.25E+07 0.0924 0.6922 Co-60 0.06431 1.18E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0055 Ni-63 442 5.22E+07 3.93E+09 0.0133 5.78E+10 0.0009 5.50E+08 0.0949 Sr-90 0.021 3.58E+04 1.40E+06 0.0256 2.06E+07 0.0017 1.96E+05 0.1827 Cs-134 0.00014 2.50E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.71E+06 3.85E+07 0.0443 5.66E+08 0.0030 5.39E+06 0.3164 Eu-152 0.00599 1.10E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.50E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 47 P286 Position #3 2

1.38E+06 H-3 1.76 2.26E+06 2.33E+08 0.0097 0.0729 3.42E+09 0.0007 0.0050 3.25E+07 0.0695 0.5209 Co-60 0.06431 8.89E+04 1.54E+08 0.0006 2.26E+09 0.0000 2.15E+07 0.0041 Ni-63 442 3.93E+07 3.93E+09 0.0100 5.78E+10 0.0007 5.50E+08 0.0714 Sr-90 0.021 2.69E+04 1.40E+06 0.0192 2.06E+07 0.0013 1.96E+05 0.1375 Cs-134 0.00014 1.88E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.28E+06 3.85E+07 0.0333 5.66E+08 0.0023 5.39E+06 0.2381 Eu-152 0.00599 8.28E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.13E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[49]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 48 P286 Position #4 1

1.27E+06 H-3 1.76 2.07E+06 2.33E+08 0.0089 0.0667 3.42E+09 0.0006 0.0045 3.25E+07 0.0636 0.4769 Co-60 0.06431 8.14E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0038 Ni-63 442 3.60E+07 3.93E+09 0.0091 5.78E+10 0.0006 5.50E+08 0.0654 Sr-90 0.021 2.47E+04 1.40E+06 0.0176 2.06E+07 0.0012 1.96E+05 0.1259 Cs-134 0.00014 1.72E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.17E+06 3.85E+07 0.0305 5.66E+08 0.0021 5.39E+06 0.2180 Eu-152 0.00599 7.58E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.03E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 49 P289 Position #1 4

3.70E+06 H-3 1.76 6.05E+06 2.33E+08 0.0259 0.1951 3.42E+09 0.0018 0.0133 3.25E+07 0.1860 1.3941 Co-60 0.06431 2.38E+05 1.54E+08 0.0015 2.26E+09 0.0001 2.15E+07 0.0111 Ni-63 442 1.05E+08 3.93E+09 0.0267 5.78E+10 0.0018 5.50E+08 0.1911 Sr-90 0.021 7.21E+04 1.40E+06 0.0515 2.06E+07 0.0035 1.96E+05 0.3680 Cs-134 0.00014 5.04E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.43E+06 3.85E+07 0.0892 5.66E+08 0.0061 5.39E+06 0.6372 Eu-152 0.00599 2.22E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 3.02E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 50 P289 Position #2 3

1.26E+06 H-3 1.76 2.06E+06 2.33E+08 0.0088 0.0664 3.42E+09 0.0006 0.0045 3.25E+07 0.0633 0.4747 Co-60 0.06431 8.10E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0038 Ni-63 442 3.58E+07 3.93E+09 0.0091 5.78E+10 0.0006 5.50E+08 0.0651 Sr-90 0.021 2.46E+04 1.40E+06 0.0175 2.06E+07 0.0012 1.96E+05 0.1253 Cs-134 0.00014 1.72E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.17E+06 3.85E+07 0.0304 5.66E+08 0.0021 5.39E+06 0.2170 Eu-152 0.00599 7.55E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.03E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 51 P289 Position #3 2

1.08E+06 H-3 1.76 1.76E+06 2.33E+08 0.0076 0.0569 3.42E+09 0.0005 0.0039 3.25E+07 0.0542 0.4064 Co-60 0.06431 6.93E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0032 Ni-63 442 3.06E+07 3.93E+09 0.0078 5.78E+10 0.0005 5.50E+08 0.0557 Sr-90 0.021 2.10E+04 1.40E+06 0.0150 2.06E+07 0.0010 1.96E+05 0.1073 Cs-134 0.00014 1.47E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.00E+06 3.85E+07 0.0260 5.66E+08 0.0018 5.39E+06 0.1858 Eu-152 0.00599 6.46E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 8.81E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 52 P289 Position #4 1

1.33E+06 H-3 1.76 2.17E+06 2.33E+08 0.0093 0.0699 3.42E+09 0.0006 0.0048 3.25E+07 0.0667 0.4997 Co-60 0.06431 8.53E+04 1.54E+08 0.0006 2.26E+09 0.0000 2.15E+07 0.0040 Ni-63 442 3.77E+07 3.93E+09 0.0096 5.78E+10 0.0007 5.50E+08 0.0685 Sr-90 0.021 2.59E+04 1.40E+06 0.0185 2.06E+07 0.0013 1.96E+05 0.1319 Cs-134 0.00014 1.81E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.23E+06 3.85E+07 0.0320 5.66E+08 0.0022 5.39E+06 0.2284 Eu-152 0.00599 7.95E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.08E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 53 P288 Position #1 4

6.19E+06 H-3 1.76 1.01E+07 2.33E+08 0.0434 0.3264 3.42E+09 0.0030 0.0222 3.25E+07 0.3112 2.3324 Co-60 0.06431 3.98E+05 1.54E+08 0.0026 2.26E+09 0.0002 2.15E+07 0.0185 Ni-63 442 1.76E+08 3.93E+09 0.0448 5.78E+10 0.0030 5.50E+08 0.3198 Sr-90 0.021 1.21E+05 1.40E+06 0.0862 2.06E+07 0.0059 1.96E+05 0.6157 Cs-134 0.00014 8.43E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 5.75E+06 3.85E+07 0.1493 5.66E+08 0.0102 5.39E+06 1.0662 Eu-152 0.00599 3.71E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0007 Eu-154 0.00082 5.06E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[50]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 54 P288 Position #2 3

1.31E+06 H-3 1.76 2.14E+06 2.33E+08 0.0092 0.0691 3.42E+09 0.0006 0.0047 3.25E+07 0.0659 0.4940 Co-60 0.06431 8.43E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0039 Ni-63 442 3.72E+07 3.93E+09 0.0095 5.78E+10 0.0006 5.50E+08 0.0677 Sr-90 0.021 2.56E+04 1.40E+06 0.0183 2.06E+07 0.0012 1.96E+05 0.1304 Cs-134 0.00014 1.79E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.22E+06 3.85E+07 0.0316 5.66E+08 0.0022 5.39E+06 0.2258 Eu-152 0.00599 7.86E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.07E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 55 P288 Position #3 2

9.83E+05 H-3 1.76 1.61E+06 2.33E+08 0.0069 0.0519 3.42E+09 0.0005 0.0035 3.25E+07 0.0494 0.3706 Co-60 0.06431 6.32E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0029 Ni-63 442 2.79E+07 3.93E+09 0.0071 5.78E+10 0.0005 5.50E+08 0.0508 Sr-90 0.021 1.92E+04 1.40E+06 0.0137 2.06E+07 0.0009 1.96E+05 0.0978 Cs-134 0.00014 1.34E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 9.13E+05 3.85E+07 0.0237 5.66E+08 0.0016 5.39E+06 0.1694 Eu-152 0.00599 5.89E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 8.04E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 56 P288 Position #4 1

1.14E+06 H-3 1.76 1.86E+06 2.33E+08 0.0080 0.0601 3.42E+09 0.0005 0.0041 3.25E+07 0.0573 0.4292 Co-60 0.06431 7.32E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0034 Ni-63 442 3.24E+07 3.93E+09 0.0082 5.78E+10 0.0006 5.50E+08 0.0588 Sr-90 0.021 2.22E+04 1.40E+06 0.0159 2.06E+07 0.0011 1.96E+05 0.1133 Cs-134 0.00014 1.55E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.06E+06 3.85E+07 0.0275 5.66E+08 0.0019 5.39E+06 0.1962 Eu-152 0.00599 6.83E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 9.31E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 57 P219 Position #1 4

4.35E+06 H-3 1.76 7.12E+06 2.33E+08 0.0305 0.2296 3.42E+09 0.0021 0.0156 3.25E+07 0.2190 1.6412 Co-60 0.06431 2.80E+05 1.54E+08 0.0018 2.26E+09 0.0001 2.15E+07 0.0130 Ni-63 442 1.24E+08 3.93E+09 0.0315 5.78E+10 0.0021 5.50E+08 0.2250 Sr-90 0.021 8.49E+04 1.40E+06 0.0607 2.06E+07 0.0041 1.96E+05 0.4332 Cs-134 0.00014 5.93E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 4.04E+06 3.85E+07 0.1050 5.66E+08 0.0071 5.39E+06 0.7502 Eu-152 0.00599 2.61E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.56E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 58 P219 Position #2 3

1.42E+06 H-3 1.76 2.33E+06 2.33E+08 0.0100 0.0751 3.42E+09 0.0007 0.0051 3.25E+07 0.0716 0.5364 Co-60 0.06431 9.15E+04 1.54E+08 0.0006 2.26E+09 0.0000 2.15E+07 0.0043 Ni-63 442 4.04E+07 3.93E+09 0.0103 5.78E+10 0.0007 5.50E+08 0.0735 Sr-90 0.021 2.78E+04 1.40E+06 0.0198 2.06E+07 0.0013 1.96E+05 0.1416 Cs-134 0.00014 1.94E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.32E+06 3.85E+07 0.0343 5.66E+08 0.0023 5.39E+06 0.2452 Eu-152 0.00599 8.53E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.16E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 59 P219 Position #3 2

1.35E+06 H-3 1.76 2.21E+06 2.33E+08 0.0095 0.0712 3.42E+09 0.0006 0.0048 3.25E+07 0.0679 0.5089 Co-60 0.06431 8.68E+04 1.54E+08 0.0006 2.26E+09 0.0000 2.15E+07 0.0040 Ni-63 442 3.84E+07 3.93E+09 0.0098 5.78E+10 0.0007 5.50E+08 0.0698 Sr-90 0.021 2.63E+04 1.40E+06 0.0188 2.06E+07 0.0013 1.96E+05 0.1343 Cs-134 0.00014 1.84E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.25E+06 3.85E+07 0.0326 5.66E+08 0.0022 5.39E+06 0.2326 Eu-152 0.00599 8.09E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.10E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[51]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 60 P219 Position #4 1

1.62E+06 H-3 1.76 2.65E+06 2.33E+08 0.0114 0.0856 3.42E+09 0.0008 0.0058 3.25E+07 0.0816 0.6118 Co-60 0.06431 1.04E+05 1.54E+08 0.0007 2.26E+09 0.0000 2.15E+07 0.0049 Ni-63 442 4.61E+07 3.93E+09 0.0117 5.78E+10 0.0008 5.50E+08 0.0839 Sr-90 0.021 3.17E+04 1.40E+06 0.0226 2.06E+07 0.0015 1.96E+05 0.1615 Cs-134 0.00014 2.21E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.51E+06 3.85E+07 0.0392 5.66E+08 0.0027 5.39E+06 0.2797 Eu-152 0.00599 9.73E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.33E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 61 P223 Position #1 4

5.87E+06 H-3 1.76 9.60E+06 2.33E+08 0.0412 0.3098 3.42E+09 0.0028 0.0211 3.25E+07 0.2955 2.2144 Co-60 0.06431 3.78E+05 1.54E+08 0.0025 2.26E+09 0.0002 2.15E+07 0.0176 Ni-63 442 1.67E+08 3.93E+09 0.0425 5.78E+10 0.0029 5.50E+08 0.3036 Sr-90 0.021 1.15E+05 1.40E+06 0.0818 2.06E+07 0.0056 1.96E+05 0.5846 Cs-134 0.00014 8.00E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 5.46E+06 3.85E+07 0.1417 5.66E+08 0.0096 5.39E+06 1.0122 Eu-152 0.00599 3.52E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0007 Eu-154 0.00082 4.80E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 62 P223 Position #2 3

1.39E+06 H-3 1.76 2.28E+06 2.33E+08 0.0098 0.0736 3.42E+09 0.0007 0.0050 3.25E+07 0.0702 0.5258 Co-60 0.06431 8.97E+04 1.54E+08 0.0006 2.26E+09 0.0000 2.15E+07 0.0042 Ni-63 442 3.96E+07 3.93E+09 0.0101 5.78E+10 0.0007 5.50E+08 0.0721 Sr-90 0.021 2.72E+04 1.40E+06 0.0194 2.06E+07 0.0013 1.96E+05 0.1388 Cs-134 0.00014 1.90E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.30E+06 3.85E+07 0.0336 5.66E+08 0.0023 5.39E+06 0.2404 Eu-152 0.00599 8.36E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.14E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 63 P223 Position #3 2

1.20E+06 H-3 1.76 1.96E+06 2.33E+08 0.0084 0.0632 3.42E+09 0.0006 0.0043 3.25E+07 0.0603 0.4516 Co-60 0.06431 7.70E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0036 Ni-63 442 3.41E+07 3.93E+09 0.0087 5.78E+10 0.0006 5.50E+08 0.0619 Sr-90 0.021 2.34E+04 1.40E+06 0.0167 2.06E+07 0.0011 1.96E+05 0.1192 Cs-134 0.00014 1.63E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.11E+06 3.85E+07 0.0289 5.66E+08 0.0020 5.39E+06 0.2065 Eu-152 0.00599 7.18E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 9.79E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 64 P223 Position #4 1

1.37E+06 H-3 1.76 2.24E+06 2.33E+08 0.0096 0.0723 3.42E+09 0.0007 0.0049 3.25E+07 0.0690 0.5168 Co-60 0.06431 8.82E+04 1.54E+08 0.0006 2.26E+09 0.0000 2.15E+07 0.0041 Ni-63 442 3.90E+07 3.93E+09 0.0099 5.78E+10 0.0007 5.50E+08 0.0708 Sr-90 0.021 2.67E+04 1.40E+06 0.0191 2.06E+07 0.0013 1.96E+05 0.1364 Cs-134 0.00014 1.87E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.27E+06 3.85E+07 0.0331 5.66E+08 0.0022 5.39E+06 0.2362 Eu-152 0.00599 8.22E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.12E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 65 P281 Position #1 0

8.17E+06 H-3 1.76 1.34E+07 2.33E+08 0.0573 0.4309 3.42E+09 0.0039 0.0293 3.25E+07 0.4109 3.0798 Co-60 0.06431 5.25E+05 1.54E+08 0.0034 2.26E+09 0.0002 2.15E+07 0.0244 Ni-63 442 2.32E+08 3.93E+09 0.0591 5.78E+10 0.0040 5.50E+08 0.4222 Sr-90 0.021 1.59E+05 1.40E+06 0.1138 2.06E+07 0.0077 1.96E+05 0.8130 Cs-134 0.00014 1.11E+03 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0003 Cs-137 0.92875 7.59E+06 3.85E+07 0.1971 5.66E+08 0.0134 5.39E+06 1.4078 Eu-152 0.00599 4.90E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0010 Eu-154 0.00082 6.68E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0002

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[52]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 66 P281 Position #2 1

1.14E+06 H-3 1.76 1.86E+06 2.33E+08 0.0080 0.0599 3.42E+09 0.0005 0.0041 3.25E+07 0.0571 0.4283 Co-60 0.06431 7.31E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0034 Ni-63 442 3.23E+07 3.93E+09 0.0082 5.78E+10 0.0006 5.50E+08 0.0587 Sr-90 0.021 2.22E+04 1.40E+06 0.0158 2.06E+07 0.0011 1.96E+05 0.1131 Cs-134 0.00014 1.55E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.06E+06 3.85E+07 0.0274 5.66E+08 0.0019 5.39E+06 0.1958 Eu-152 0.00599 6.81E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 9.29E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 67 P281 Position #3 2

7.79E+05 H-3 1.76 1.27E+06 2.33E+08 0.0055 0.0411 3.42E+09 0.0004 0.0028 3.25E+07 0.0392 0.2938 Co-60 0.06431 5.01E+04 1.54E+08 0.0003 2.26E+09 0.0000 2.15E+07 0.0023 Ni-63 442 2.22E+07 3.93E+09 0.0056 5.78E+10 0.0004 5.50E+08 0.0403 Sr-90 0.021 1.52E+04 1.40E+06 0.0109 2.06E+07 0.0007 1.96E+05 0.0775 Cs-134 0.00014 1.06E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.24E+05 3.85E+07 0.0188 5.66E+08 0.0013 5.39E+06 0.1343 Eu-152 0.00599 4.67E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 6.37E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 68 P281 Position #4 3

7.97E+05 H-3 1.76 1.30E+06 2.33E+08 0.0056 0.0420 3.42E+09 0.0004 0.0029 3.25E+07 0.0401 0.3004 Co-60 0.06431 5.12E+04 1.54E+08 0.0003 2.26E+09 0.0000 2.15E+07 0.0024 Ni-63 442 2.27E+07 3.93E+09 0.0058 5.78E+10 0.0004 5.50E+08 0.0412 Sr-90 0.021 1.55E+04 1.40E+06 0.0111 2.06E+07 0.0008 1.96E+05 0.0793 Cs-134 0.00014 1.09E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.40E+05 3.85E+07 0.0192 5.66E+08 0.0013 5.39E+06 0.1373 Eu-152 0.00599 4.78E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 6.51E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 69 P281 Position #5 4

7.67E+05 H-3 1.76 1.25E+06 2.33E+08 0.0054 0.0404 3.42E+09 0.0004 0.0028 3.25E+07 0.0386 0.2890 Co-60 0.06431 4.93E+04 1.54E+08 0.0003 2.26E+09 0.0000 2.15E+07 0.0023 Ni-63 442 2.18E+07 3.93E+09 0.0055 5.78E+10 0.0004 5.50E+08 0.0396 Sr-90 0.021 1.50E+04 1.40E+06 0.0107 2.06E+07 0.0007 1.96E+05 0.0763 Cs-134 0.00014 1.04E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.12E+05 3.85E+07 0.0185 5.66E+08 0.0013 5.39E+06 0.1321 Eu-152 0.00599 4.60E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 6.27E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 70 P243 Position #1 0

1.09E+07 H-3 1.76 1.78E+07 2.33E+08 0.0762 0.5728 3.42E+09 0.0052 0.0390 3.25E+07 0.5462 4.0938 Co-60 0.06431 6.98E+05 1.54E+08 0.0045 2.26E+09 0.0003 2.15E+07 0.0325 Ni-63 442 3.09E+08 3.93E+09 0.0785 5.78E+10 0.0053 5.50E+08 0.5612 Sr-90 0.021 2.12E+05 1.40E+06 0.1513 2.06E+07 0.0103 1.96E+05 1.0807 Cs-134 0.00014 1.48E+03 2.94E+07 0.0001 4.32E+08 0.0000 4.12E+06 0.0004 Cs-137 0.92875 1.01E+07 3.85E+07 0.2620 5.66E+08 0.0178 5.39E+06 1.8713 Eu-152 0.00599 6.51E+04 3.58E+08 0.0002 5.26E+09 0.0000 5.00E+07 0.0013 Eu-154 0.00082 8.88E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0002 71 P243 Position #2 1

1.27E+06 H-3 1.76 2.07E+06 2.33E+08 0.0089 0.0668 3.42E+09 0.0006 0.0045 3.25E+07 0.0637 0.4776 Co-60 0.06431 8.15E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0038 Ni-63 442 3.60E+07 3.93E+09 0.0092 5.78E+10 0.0006 5.50E+08 0.0655 Sr-90 0.021 2.47E+04 1.40E+06 0.0177 2.06E+07 0.0012 1.96E+05 0.1261 Cs-134 0.00014 1.73E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.18E+06 3.85E+07 0.0306 5.66E+08 0.0021 5.39E+06 0.2183 Eu-152 0.00599 7.60E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.04E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[53]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 72 P243 Position #3 2

9.02E+05 H-3 1.76 1.48E+06 2.33E+08 0.0063 0.0476 3.42E+09 0.0004 0.0032 3.25E+07 0.0454 0.3402 Co-60 0.06431 5.80E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0027 Ni-63 442 2.57E+07 3.93E+09 0.0065 5.78E+10 0.0004 5.50E+08 0.0466 Sr-90 0.021 1.76E+04 1.40E+06 0.0126 2.06E+07 0.0009 1.96E+05 0.0898 Cs-134 0.00014 1.23E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 8.38E+05 3.85E+07 0.0218 5.66E+08 0.0015 5.39E+06 0.1555 Eu-152 0.00599 5.41E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.38E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 73 P243 Position #4 3

8.62E+05 H-3 1.76 1.41E+06 2.33E+08 0.0060 0.0455 3.42E+09 0.0004 0.0031 3.25E+07 0.0434 0.3250 Co-60 0.06431 5.54E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0026 Ni-63 442 2.45E+07 3.93E+09 0.0062 5.78E+10 0.0004 5.50E+08 0.0446 Sr-90 0.021 1.68E+04 1.40E+06 0.0120 2.06E+07 0.0008 1.96E+05 0.0858 Cs-134 0.00014 1.17E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 8.01E+05 3.85E+07 0.0208 5.66E+08 0.0014 5.39E+06 0.1486 Eu-152 0.00599 5.17E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.05E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 74 P243 Position #5 4

8.57E+05 H-3 1.76 1.40E+06 2.33E+08 0.0060 0.0452 3.42E+09 0.0004 0.0031 3.25E+07 0.0431 0.3231 Co-60 0.06431 5.51E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0026 Ni-63 442 2.44E+07 3.93E+09 0.0062 5.78E+10 0.0004 5.50E+08 0.0443 Sr-90 0.021 1.67E+04 1.40E+06 0.0119 2.06E+07 0.0008 1.96E+05 0.0853 Cs-134 0.00014 1.17E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.96E+05 3.85E+07 0.0207 5.66E+08 0.0014 5.39E+06 0.1477 Eu-152 0.00599 5.14E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.01E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 75 P303 Position #1 0

1.27E+07 H-3 1.76 2.07E+07 2.33E+08 0.0889 0.6683 3.42E+09 0.0061 0.0455 3.25E+07 0.6372 4.7760 Co-60 0.06431 8.15E+05 1.54E+08 0.0053 2.26E+09 0.0004 2.15E+07 0.0379 Ni-63 442 3.60E+08 3.93E+09 0.0916 5.78E+10 0.0062 5.50E+08 0.6548 Sr-90 0.021 2.47E+05 1.40E+06 0.1765 2.06E+07 0.0120 1.96E+05 1.2608 Cs-134 0.00014 1.73E+03 2.94E+07 0.0001 4.32E+08 0.0000 4.12E+06 0.0004 Cs-137 0.92875 1.18E+07 3.85E+07 0.3056 5.66E+08 0.0208 5.39E+06 2.1832 Eu-152 0.00599 7.60E+04 3.58E+08 0.0002 5.26E+09 0.0000 5.00E+07 0.0015 Eu-154 0.00082 1.04E+04 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0002 76 P303 Position #2 1

4.17E+06 H-3 1.76 6.82E+06 2.33E+08 0.0293 0.2201 3.42E+09 0.0020 0.0150 3.25E+07 0.2099 1.5731 Co-60 0.06431 2.68E+05 1.54E+08 0.0017 2.26E+09 0.0001 2.15E+07 0.0125 Ni-63 442 1.19E+08 3.93E+09 0.0302 5.78E+10 0.0021 5.50E+08 0.2157 Sr-90 0.021 8.14E+04 1.40E+06 0.0581 2.06E+07 0.0040 1.96E+05 0.4153 Cs-134 0.00014 5.69E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.88E+06 3.85E+07 0.1007 5.66E+08 0.0068 5.39E+06 0.7191 Eu-152 0.00599 2.50E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.41E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 77 P303 Position #3 2

5.51E+06 H-3 1.76 9.00E+06 2.33E+08 0.0386 0.2904 3.42E+09 0.0026 0.0198 3.25E+07 0.2769 2.0753 Co-60 0.06431 3.54E+05 1.54E+08 0.0023 2.26E+09 0.0002 2.15E+07 0.0165 Ni-63 442 1.56E+08 3.93E+09 0.0398 5.78E+10 0.0027 5.50E+08 0.2845 Sr-90 0.021 1.07E+05 1.40E+06 0.0767 2.06E+07 0.0052 1.96E+05 0.5478 Cs-134 0.00014 7.50E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 5.11E+06 3.85E+07 0.1328 5.66E+08 0.0090 5.39E+06 0.9486 Eu-152 0.00599 3.30E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0007 Eu-154 0.00082 4.50E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[54]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 78 P303 Position #4 3

4.95E+06 H-3 1.76 8.10E+06 2.33E+08 0.0347 0.2612 3.42E+09 0.0024 0.0178 3.25E+07 0.2491 1.8668 Co-60 0.06431 3.18E+05 1.54E+08 0.0021 2.26E+09 0.0001 2.15E+07 0.0148 Ni-63 442 1.41E+08 3.93E+09 0.0358 5.78E+10 0.0024 5.50E+08 0.2559 Sr-90 0.021 9.66E+04 1.40E+06 0.0690 2.06E+07 0.0047 1.96E+05 0.4928 Cs-134 0.00014 6.75E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 4.60E+06 3.85E+07 0.1195 5.66E+08 0.0081 5.39E+06 0.8533 Eu-152 0.00599 2.97E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0006 Eu-154 0.00082 4.05E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 79 P303 Position #5 4

4.17E+06 H-3 1.76 6.82E+06 2.33E+08 0.0293 0.2201 3.42E+09 0.0020 0.0150 3.25E+07 0.2099 1.5731 Co-60 0.06431 2.68E+05 1.54E+08 0.0017 2.26E+09 0.0001 2.15E+07 0.0125 Ni-63 442 1.19E+08 3.93E+09 0.0302 5.78E+10 0.0021 5.50E+08 0.2157 Sr-90 0.021 8.14E+04 1.40E+06 0.0581 2.06E+07 0.0040 1.96E+05 0.4153 Cs-134 0.00014 5.69E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.88E+06 3.85E+07 0.1007 5.66E+08 0.0068 5.39E+06 0.7191 Eu-152 0.00599 2.50E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.41E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 80 P303 Position #6 5

5.73E+06 H-3 1.76 9.37E+06 2.33E+08 0.0402 0.3023 3.42E+09 0.0027 0.0206 3.25E+07 0.2883 2.1606 Co-60 0.06431 3.69E+05 1.54E+08 0.0024 2.26E+09 0.0002 2.15E+07 0.0171 Ni-63 442 1.63E+08 3.93E+09 0.0415 5.78E+10 0.0028 5.50E+08 0.2962 Sr-90 0.021 1.12E+05 1.40E+06 0.0798 2.06E+07 0.0054 1.96E+05 0.5704 Cs-134 0.00014 7.81E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 5.32E+06 3.85E+07 0.1383 5.66E+08 0.0094 5.39E+06 0.9876 Eu-152 0.00599 3.44E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0007 Eu-154 0.00082 4.69E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 81 P256 Position #1 0

7.59E+06 H-3 1.76 1.24E+07 2.33E+08 0.0533 0.4004 3.42E+09 0.0036 0.0272 3.25E+07 0.3818 2.8618 Co-60 0.06431 4.88E+05 1.54E+08 0.0032 2.26E+09 0.0002 2.15E+07 0.0227 Ni-63 442 2.16E+08 3.93E+09 0.0549 5.78E+10 0.0037 5.50E+08 0.3923 Sr-90 0.021 1.48E+05 1.40E+06 0.1058 2.06E+07 0.0072 1.96E+05 0.7555 Cs-134 0.00014 1.03E+03 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0003 Cs-137 0.92875 7.05E+06 3.85E+07 0.1831 5.66E+08 0.0125 5.39E+06 1.3082 Eu-152 0.00599 4.55E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0009 Eu-154 0.00082 6.21E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 82 P256 Position #2 1

9.00E+05 H-3 1.76 1.47E+06 2.33E+08 0.0063 0.0475 3.42E+09 0.0004 0.0032 3.25E+07 0.0453 0.3393 Co-60 0.06431 5.79E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0027 Ni-63 442 2.56E+07 3.93E+09 0.0065 5.78E+10 0.0004 5.50E+08 0.0465 Sr-90 0.021 1.76E+04 1.40E+06 0.0125 2.06E+07 0.0009 1.96E+05 0.0896 Cs-134 0.00014 1.23E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 8.36E+05 3.85E+07 0.0217 5.66E+08 0.0015 5.39E+06 0.1551 Eu-152 0.00599 5.39E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.36E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 83 P256 Position #3 2

7.21E+05 H-3 1.76 1.18E+06 2.33E+08 0.0051 0.0381 3.42E+09 0.0003 0.0026 3.25E+07 0.0363 0.2720 Co-60 0.06431 4.64E+04 1.54E+08 0.0003 2.26E+09 0.0000 2.15E+07 0.0022 Ni-63 442 2.05E+07 3.93E+09 0.0052 5.78E+10 0.0004 5.50E+08 0.0373 Sr-90 0.021 1.41E+04 1.40E+06 0.0101 2.06E+07 0.0007 1.96E+05 0.0718 Cs-134 0.00014 9.83E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 6.70E+05 3.85E+07 0.0174 5.66E+08 0.0012 5.39E+06 0.1243 Eu-152 0.00599 4.33E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 5.90E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[55]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 84 P256 Position #4 3

6.74E+05 H-3 1.76 1.10E+06 2.33E+08 0.0047 0.0355 3.42E+09 0.0003 0.0024 3.25E+07 0.0339 0.2540 Co-60 0.06431 4.33E+04 1.54E+08 0.0003 2.26E+09 0.0000 2.15E+07 0.0020 Ni-63 442 1.91E+07 3.93E+09 0.0049 5.78E+10 0.0003 5.50E+08 0.0348 Sr-90 0.021 1.31E+04 1.40E+06 0.0094 2.06E+07 0.0006 1.96E+05 0.0670 Cs-134 0.00014 9.18E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 6.26E+05 3.85E+07 0.0163 5.66E+08 0.0011 5.39E+06 0.1161 Eu-152 0.00599 4.04E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 5.51E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 85 P256 Position #5 4

7.39E+05 H-3 1.76 1.21E+06 2.33E+08 0.0052 0.0390 3.42E+09 0.0004 0.0027 3.25E+07 0.0372 0.2786 Co-60 0.06431 4.75E+04 1.54E+08 0.0003 2.26E+09 0.0000 2.15E+07 0.0022 Ni-63 442 2.10E+07 3.93E+09 0.0053 5.78E+10 0.0004 5.50E+08 0.0382 Sr-90 0.021 1.44E+04 1.40E+06 0.0103 2.06E+07 0.0007 1.96E+05 0.0735 Cs-134 0.00014 1.01E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 6.86E+05 3.85E+07 0.0178 5.66E+08 0.0012 5.39E+06 0.1274 Eu-152 0.00599 4.43E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 6.04E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 86 P204 Position #1 0

7.44E+06 H-3 1.76 1.22E+07 2.33E+08 0.0522 0.3925 3.42E+09 0.0036 0.0267 3.25E+07 0.3743 2.8050 Co-60 0.06431 4.79E+05 1.54E+08 0.0031 2.26E+09 0.0002 2.15E+07 0.0223 Ni-63 442 2.11E+08 3.93E+09 0.0538 5.78E+10 0.0037 5.50E+08 0.3845 Sr-90 0.021 1.45E+05 1.40E+06 0.1037 2.06E+07 0.0070 1.96E+05 0.7405 Cs-134 0.00014 1.01E+03 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 6.91E+06 3.85E+07 0.1795 5.66E+08 0.0122 5.39E+06 1.2822 Eu-152 0.00599 4.46E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0009 Eu-154 0.00082 6.08E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 87 P204 Position #2 1

1.12E+06 H-3 1.76 1.84E+06 2.33E+08 0.0079 0.0593 3.42E+09 0.0005 0.0040 3.25E+07 0.0565 0.4236 Co-60 0.06431 7.23E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0034 Ni-63 442 3.19E+07 3.93E+09 0.0081 5.78E+10 0.0006 5.50E+08 0.0581 Sr-90 0.021 2.19E+04 1.40E+06 0.0157 2.06E+07 0.0011 1.96E+05 0.1118 Cs-134 0.00014 1.53E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.04E+06 3.85E+07 0.0271 5.66E+08 0.0018 5.39E+06 0.1936 Eu-152 0.00599 6.74E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 9.19E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 88 P204 Position #3 2

9.55E+05 H-3 1.76 1.56E+06 2.33E+08 0.0067 0.0504 3.42E+09 0.0005 0.0034 3.25E+07 0.0480 0.3601 Co-60 0.06431 6.14E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0029 Ni-63 442 2.72E+07 3.93E+09 0.0069 5.78E+10 0.0005 5.50E+08 0.0494 Sr-90 0.021 1.86E+04 1.40E+06 0.0133 2.06E+07 0.0009 1.96E+05 0.0951 Cs-134 0.00014 1.30E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 8.87E+05 3.85E+07 0.0230 5.66E+08 0.0016 5.39E+06 0.1646 Eu-152 0.00599 5.73E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.81E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 89 P204 Position #4 3

1.03E+06 H-3 1.76 1.68E+06 2.33E+08 0.0072 0.0544 3.42E+09 0.0005 0.0037 3.25E+07 0.0518 0.3885 Co-60 0.06431 6.63E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0031 Ni-63 442 2.93E+07 3.93E+09 0.0075 5.78E+10 0.0005 5.50E+08 0.0533 Sr-90 0.021 2.01E+04 1.40E+06 0.0144 2.06E+07 0.0010 1.96E+05 0.1026 Cs-134 0.00014 1.40E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 9.57E+05 3.85E+07 0.0249 5.66E+08 0.0017 5.39E+06 0.1776 Eu-152 0.00599 6.18E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 8.43E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[56]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 90 P204 Position #5 4

8.82E+05 H-3 1.76 1.44E+06 2.33E+08 0.0062 0.0465 3.42E+09 0.0004 0.0032 3.25E+07 0.0444 0.3326 Co-60 0.06431 5.67E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0026 Ni-63 442 2.51E+07 3.93E+09 0.0064 5.78E+10 0.0004 5.50E+08 0.0456 Sr-90 0.021 1.72E+04 1.40E+06 0.0123 2.06E+07 0.0008 1.96E+05 0.0878 Cs-134 0.00014 1.20E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 8.20E+05 3.85E+07 0.0213 5.66E+08 0.0014 5.39E+06 0.1520 Eu-152 0.00599 5.29E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.21E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 91 P242 Position #1 0

6.06E+06 H-3 1.76 9.91E+06 2.33E+08 0.0425 0.3197 3.42E+09 0.0029 0.0217 3.25E+07 0.3048 2.2848 Co-60 0.06431 3.90E+05 1.54E+08 0.0025 2.26E+09 0.0002 2.15E+07 0.0181 Ni-63 442 1.72E+08 3.93E+09 0.0438 5.78E+10 0.0030 5.50E+08 0.3132 Sr-90 0.021 1.18E+05 1.40E+06 0.0844 2.06E+07 0.0057 1.96E+05 0.6031 Cs-134 0.00014 8.26E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 5.63E+06 3.85E+07 0.1462 5.66E+08 0.0099 5.39E+06 1.0444 Eu-152 0.00599 3.63E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0007 Eu-154 0.00082 4.95E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 92 P242 Position #2 1

1.11E+06 H-3 1.76 1.81E+06 2.33E+08 0.0078 0.0585 3.42E+09 0.0005 0.0040 3.25E+07 0.0558 0.4179 Co-60 0.06431 7.13E+04 1.54E+08 0.0005 2.26E+09 0.0000 2.15E+07 0.0033 Ni-63 442 3.15E+07 3.93E+09 0.0080 5.78E+10 0.0005 5.50E+08 0.0573 Sr-90 0.021 2.16E+04 1.40E+06 0.0154 2.06E+07 0.0010 1.96E+05 0.1103 Cs-134 0.00014 1.51E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.03E+06 3.85E+07 0.0267 5.66E+08 0.0018 5.39E+06 0.1910 Eu-152 0.00599 6.65E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 9.06E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 93 P242 Position #3 2

9.30E+05 H-3 1.76 1.52E+06 2.33E+08 0.0065 0.0491 3.42E+09 0.0004 0.0033 3.25E+07 0.0468 0.3507 Co-60 0.06431 5.98E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0028 Ni-63 442 2.64E+07 3.93E+09 0.0067 5.78E+10 0.0005 5.50E+08 0.0481 Sr-90 0.021 1.81E+04 1.40E+06 0.0130 2.06E+07 0.0009 1.96E+05 0.0926 Cs-134 0.00014 1.27E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 8.64E+05 3.85E+07 0.0224 5.66E+08 0.0015 5.39E+06 0.1603 Eu-152 0.00599 5.58E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.61E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 94 P242 Position #4 3

9.76E+05 H-3 1.76 1.59E+06 2.33E+08 0.0068 0.0515 3.42E+09 0.0005 0.0035 3.25E+07 0.0491 0.3678 Co-60 0.06431 6.27E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0029 Ni-63 442 2.77E+07 3.93E+09 0.0071 5.78E+10 0.0005 5.50E+08 0.0504 Sr-90 0.021 1.90E+04 1.40E+06 0.0136 2.06E+07 0.0009 1.96E+05 0.0971 Cs-134 0.00014 1.33E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 9.06E+05 3.85E+07 0.0235 5.66E+08 0.0016 5.39E+06 0.1681 Eu-152 0.00599 5.85E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.98E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 95 P242 Position #5 4

9.49E+05 H-3 1.76 1.55E+06 2.33E+08 0.0067 0.0501 3.42E+09 0.0005 0.0034 3.25E+07 0.0477 0.3577 Co-60 0.06431 6.10E+04 1.54E+08 0.0004 2.26E+09 0.0000 2.15E+07 0.0028 Ni-63 442 2.70E+07 3.93E+09 0.0069 5.78E+10 0.0005 5.50E+08 0.0490 Sr-90 0.021 1.85E+04 1.40E+06 0.0132 2.06E+07 0.0009 1.96E+05 0.0944 Cs-134 0.00014 1.29E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 8.81E+05 3.85E+07 0.0229 5.66E+08 0.0016 5.39E+06 0.1635 Eu-152 0.00599 5.69E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0001 Eu-154 0.00082 7.76E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[57]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 96 P266 By Direct Scan N/A 1.81E+05 H-3 1.76 2.95E+05 2.33E+08 0.0013 0.0095 3.42E+09 0.0001 0.0006 3.25E+07 0.0091 0.0681 Co-60 0.06431 1.16E+04 1.54E+08 0.0001 2.26E+09 0.0000 2.15E+07 0.0005 Ni-63 442 5.14E+06 3.93E+09 0.0013 5.78E+10 0.0001 5.50E+08 0.0093 Sr-90 0.021 3.52E+03 1.40E+06 0.0025 2.06E+07 0.0002 1.96E+05 0.0180 Cs-134 0.00014 2.46E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.68E+05 3.85E+07 0.0044 5.66E+08 0.0003 5.39E+06 0.0311 Eu-152 0.00599 1.08E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 1.48E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 97 P269 By Direct Scan N/A 3.85E+04 H-3 1.76 6.29E+04 2.33E+08 0.0003 0.0020 3.42E+09 0.0000 0.0001 3.25E+07 0.0019 0.0145 Co-60 0.06431 2.48E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.09E+06 3.93E+09 0.0003 5.78E+10 0.0000 5.50E+08 0.0020 Sr-90 0.021 7.51E+02 1.40E+06 0.0005 2.06E+07 0.0000 1.96E+05 0.0038 Cs-134 0.00014 5.24E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 3.58E+04 3.85E+07 0.0009 5.66E+08 0.0001 5.39E+06 0.0066 Eu-152 0.00599 2.31E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 3.15E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 98 P274 By Direct Scan N/A 3.85E+04 H-3 1.76 6.29E+04 2.33E+08 0.0003 0.0020 3.42E+09 0.0000 0.0001 3.25E+07 0.0019 0.0145 Co-60 0.06431 2.48E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.09E+06 3.93E+09 0.0003 5.78E+10 0.0000 5.50E+08 0.0020 Sr-90 0.021 7.51E+02 1.40E+06 0.0005 2.06E+07 0.0000 1.96E+05 0.0038 Cs-134 0.00014 5.24E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 3.58E+04 3.85E+07 0.0009 5.66E+08 0.0001 5.39E+06 0.0066 Eu-152 0.00599 2.31E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 3.15E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 99 P208 By Direct Scan N/A 4.43E+04 H-3 1.76 7.24E+04 2.33E+08 0.0003 0.0023 3.42E+09 0.0000 0.0002 3.25E+07 0.0022 0.0167 Co-60 0.06431 2.85E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.26E+06 3.93E+09 0.0003 5.78E+10 0.0000 5.50E+08 0.0023 Sr-90 0.021 8.64E+02 1.40E+06 0.0006 2.06E+07 0.0000 1.96E+05 0.0044 Cs-134 0.00014 6.03E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 4.11E+04 3.85E+07 0.0011 5.66E+08 0.0001 5.39E+06 0.0076 Eu-152 0.00599 2.65E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 3.62E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 100 P318 By Direct Scan N/A 5.47E+04 H-3 1.76 8.95E+04 2.33E+08 0.0004 0.0029 3.42E+09 0.0000 0.0002 3.25E+07 0.0028 0.0206 Co-60 0.06431 3.52E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.56E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0028 Sr-90 0.021 1.07E+03 1.40E+06 0.0008 2.06E+07 0.0001 1.96E+05 0.0054 Cs-134 0.00014 7.46E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 5.08E+04 3.85E+07 0.0013 5.66E+08 0.0001 5.39E+06 0.0094 Eu-152 0.00599 3.28E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.47E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 101 P317 By Direct Scan N/A 4.95E+04 H-3 1.76 8.09E+04 2.33E+08 0.0003 0.0026 3.42E+09 0.0000 0.0002 3.25E+07 0.0025 0.0187 Co-60 0.06431 3.18E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.41E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0026 Sr-90 0.021 9.66E+02 1.40E+06 0.0007 2.06E+07 0.0000 1.96E+05 0.0049 Cs-134 0.00014 6.74E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 4.60E+04 3.85E+07 0.0012 5.66E+08 0.0001 5.39E+06 0.0085 Eu-152 0.00599 2.97E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.05E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[58]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 102 P212 By Direct Scan N/A 5.72E+04 H-3 1.76 9.35E+04 2.33E+08 0.0004 0.0030 3.42E+09 0.0000 0.0002 3.25E+07 0.0029 0.0216 Co-60 0.06431 3.68E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.63E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0030 Sr-90 0.021 1.12E+03 1.40E+06 0.0008 2.06E+07 0.0001 1.96E+05 0.0057 Cs-134 0.00014 7.79E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 5.31E+04 3.85E+07 0.0014 5.66E+08 0.0001 5.39E+06 0.0099 Eu-152 0.00599 3.43E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.67E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 103 P298 By Direct Scan N/A 4.25E+04 H-3 1.76 6.95E+04 2.33E+08 0.0003 0.0022 3.42E+09 0.0000 0.0002 3.25E+07 0.0021 0.0160 Co-60 0.06431 2.74E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.21E+06 3.93E+09 0.0003 5.78E+10 0.0000 5.50E+08 0.0022 Sr-90 0.021 8.30E+02 1.40E+06 0.0006 2.06E+07 0.0000 1.96E+05 0.0042 Cs-134 0.00014 5.79E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 3.95E+04 3.85E+07 0.0010 5.66E+08 0.0001 5.39E+06 0.0073 Eu-152 0.00599 2.55E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 3.48E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 104 P313 By Direct Scan N/A 4.01E+04 H-3 1.76 6.55E+04 2.33E+08 0.0003 0.0021 3.42E+09 0.0000 0.0001 3.25E+07 0.0020 0.0151 Co-60 0.06431 2.58E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.14E+06 3.93E+09 0.0003 5.78E+10 0.0000 5.50E+08 0.0021 Sr-90 0.021 7.82E+02 1.40E+06 0.0006 2.06E+07 0.0000 1.96E+05 0.0040 Cs-134 0.00014 5.46E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 3.72E+04 3.85E+07 0.0010 5.66E+08 0.0001 5.39E+06 0.0069 Eu-152 0.00599 2.40E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 3.28E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 105 P297 By Direct Scan N/A 4.01E+04 H-3 1.76 6.55E+04 2.33E+08 0.0003 0.0021 3.42E+09 0.0000 0.0001 3.25E+07 0.0020 0.0151 Co-60 0.06431 2.58E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.14E+06 3.93E+09 0.0003 5.78E+10 0.0000 5.50E+08 0.0021 Sr-90 0.021 7.82E+02 1.40E+06 0.0006 2.06E+07 0.0000 1.96E+05 0.0040 Cs-134 0.00014 5.46E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 3.72E+04 3.85E+07 0.0010 5.66E+08 0.0001 5.39E+06 0.0069 Eu-152 0.00599 2.40E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 3.28E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 106 P328 By Direct Scan N/A 4.43E+04 H-3 1.76 7.24E+04 2.33E+08 0.0003 0.0023 3.42E+09 0.0000 0.0002 3.25E+07 0.0022 0.0167 Co-60 0.06431 2.85E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.26E+06 3.93E+09 0.0003 5.78E+10 0.0000 5.50E+08 0.0023 Sr-90 0.021 8.64E+02 1.40E+06 0.0006 2.06E+07 0.0000 1.96E+05 0.0044 Cs-134 0.00014 6.03E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 4.11E+04 3.85E+07 0.0011 5.66E+08 0.0001 5.39E+06 0.0076 Eu-152 0.00599 2.65E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 3.62E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 107 P316 By Direct Scan N/A 6.76E+04 H-3 1.76 1.11E+05 2.33E+08 0.0005 0.0036 3.42E+09 0.0000 0.0002 3.25E+07 0.0034 0.0255 Co-60 0.06431 4.35E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.92E+06 3.93E+09 0.0005 5.78E+10 0.0000 5.50E+08 0.0035 Sr-90 0.021 1.32E+03 1.40E+06 0.0009 2.06E+07 0.0001 1.96E+05 0.0067 Cs-134 0.00014 9.21E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 6.28E+04 3.85E+07 0.0016 5.66E+08 0.0001 5.39E+06 0.0117 Eu-152 0.00599 4.05E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 5.53E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[59]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 108 P294 By Direct Scan N/A 3.73E+04 H-3 1.76 6.10E+04 2.33E+08 0.0003 0.0020 3.42E+09 0.0000 0.0001 3.25E+07 0.0019 0.0141 Co-60 0.06431 2.40E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0001 Ni-63 442 1.06E+06 3.93E+09 0.0003 5.78E+10 0.0000 5.50E+08 0.0019 Sr-90 0.021 7.28E+02 1.40E+06 0.0005 2.06E+07 0.0000 1.96E+05 0.0037 Cs-134 0.00014 5.08E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 3.46E+04 3.85E+07 0.0009 5.66E+08 0.0001 5.39E+06 0.0064 Eu-152 0.00599 2.24E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 3.05E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 109 P293 By Direct Scan N/A 5.13E+04 H-3 1.76 8.38E+04 2.33E+08 0.0004 0.0027 3.42E+09 0.0000 0.0002 3.25E+07 0.0026 0.0193 Co-60 0.06431 3.30E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.46E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0026 Sr-90 0.021 1.00E+03 1.40E+06 0.0007 2.06E+07 0.0000 1.96E+05 0.0051 Cs-134 0.00014 6.98E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 4.76E+04 3.85E+07 0.0012 5.66E+08 0.0001 5.39E+06 0.0088 Eu-152 0.00599 3.07E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.19E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 110 P210 By Direct Scan N/A 1.24E+05 H-3 1.76 2.02E+05 2.33E+08 0.0009 0.0065 3.42E+09 0.0001 0.0004 3.25E+07 0.0062 0.0467 Co-60 0.06431 7.96E+03 1.54E+08 0.0001 2.26E+09 0.0000 2.15E+07 0.0004 Ni-63 442 3.52E+06 3.93E+09 0.0009 5.78E+10 0.0001 5.50E+08 0.0064 Sr-90 0.021 2.41E+03 1.40E+06 0.0017 2.06E+07 0.0001 1.96E+05 0.0123 Cs-134 0.00014 1.69E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.15E+05 3.85E+07 0.0030 5.66E+08 0.0002 5.39E+06 0.0213 Eu-152 0.00599 7.42E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 1.01E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 111 P312 By Direct Scan N/A 5.40E+04 H-3 1.76 8.83E+04 2.33E+08 0.0004 0.0029 3.42E+09 0.0000 0.0002 3.25E+07 0.0027 0.0204 Co-60 0.06431 3.48E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.54E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0028 Sr-90 0.021 1.05E+03 1.40E+06 0.0008 2.06E+07 0.0001 1.96E+05 0.0054 Cs-134 0.00014 7.36E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 5.02E+04 3.85E+07 0.0013 5.66E+08 0.0001 5.39E+06 0.0093 Eu-152 0.00599 3.24E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.42E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 112 P295 By Direct Scan N/A 5.30E+04 H-3 1.76 8.66E+04 2.33E+08 0.0004 0.0028 3.42E+09 0.0000 0.0002 3.25E+07 0.0027 0.0200 Co-60 0.06431 3.41E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.51E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0027 Sr-90 0.021 1.03E+03 1.40E+06 0.0007 2.06E+07 0.0001 1.96E+05 0.0053 Cs-134 0.00014 7.22E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 4.92E+04 3.85E+07 0.0013 5.66E+08 0.0001 5.39E+06 0.0091 Eu-152 0.00599 3.18E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.33E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 113 P291 By Direct Scan N/A 8.58E+04 H-3 1.76 1.40E+05 2.33E+08 0.0006 0.0045 3.42E+09 0.0000 0.0003 3.25E+07 0.0043 0.0323 Co-60 0.06431 5.52E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0003 Ni-63 442 2.44E+06 3.93E+09 0.0006 5.78E+10 0.0000 5.50E+08 0.0044 Sr-90 0.021 1.67E+03 1.40E+06 0.0012 2.06E+07 0.0001 1.96E+05 0.0085 Cs-134 0.00014 1.17E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 7.97E+04 3.85E+07 0.0021 5.66E+08 0.0001 5.39E+06 0.0148 Eu-152 0.00599 5.14E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 7.01E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[60]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 114 P270 By Direct Scan N/A 2.63E+05 H-3 1.76 4.30E+05 2.33E+08 0.0018 0.0139 3.42E+09 0.0001 0.0009 3.25E+07 0.0132 0.0992 Co-60 0.06431 1.69E+04 1.54E+08 0.0001 2.26E+09 0.0000 2.15E+07 0.0008 Ni-63 442 7.48E+06 3.93E+09 0.0019 5.78E+10 0.0001 5.50E+08 0.0136 Sr-90 0.021 5.13E+03 1.40E+06 0.0037 2.06E+07 0.0002 1.96E+05 0.0262 Cs-134 0.00014 3.59E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 2.44E+05 3.85E+07 0.0063 5.66E+08 0.0004 5.39E+06 0.0454 Eu-152 0.00599 1.58E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 2.15E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 115 P268 By Direct Scan N/A 1.96E+05 H-3 1.76 3.20E+05 2.33E+08 0.0014 0.0103 3.42E+09 0.0001 0.0007 3.25E+07 0.0098 0.0737 Co-60 0.06431 1.26E+04 1.54E+08 0.0001 2.26E+09 0.0000 2.15E+07 0.0006 Ni-63 442 5.56E+06 3.93E+09 0.0014 5.78E+10 0.0001 5.50E+08 0.0101 Sr-90 0.021 3.81E+03 1.40E+06 0.0027 2.06E+07 0.0002 1.96E+05 0.0195 Cs-134 0.00014 2.66E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.82E+05 3.85E+07 0.0047 5.66E+08 0.0003 5.39E+06 0.0337 Eu-152 0.00599 1.17E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 1.60E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 116 P222 By Direct Scan N/A 6.07E+04 H-3 1.76 9.92E+04 2.33E+08 0.0004 0.0032 3.42E+09 0.0000 0.0002 3.25E+07 0.0031 0.0229 Co-60 0.06431 3.90E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.72E+06 3.93E+09 0.0004 5.78E+10 0.0000 5.50E+08 0.0031 Sr-90 0.021 1.18E+03 1.40E+06 0.0008 2.06E+07 0.0001 1.96E+05 0.0060 Cs-134 0.00014 8.26E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 5.63E+04 3.85E+07 0.0015 5.66E+08 0.0001 5.39E+06 0.0105 Eu-152 0.00599 3.64E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 4.96E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 117 P304 By Direct Scan N/A 2.10E+05 H-3 1.76 3.43E+05 2.33E+08 0.0015 0.0111 3.42E+09 0.0001 0.0008 3.25E+07 0.0106 0.0791 Co-60 0.06431 1.35E+04 1.54E+08 0.0001 2.26E+09 0.0000 2.15E+07 0.0006 Ni-63 442 5.97E+06 3.93E+09 0.0015 5.78E+10 0.0001 5.50E+08 0.0108 Sr-90 0.021 4.09E+03 1.40E+06 0.0029 2.06E+07 0.0002 1.96E+05 0.0209 Cs-134 0.00014 2.86E+01 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 1.95E+05 3.85E+07 0.0051 5.66E+08 0.0003 5.39E+06 0.0362 Eu-152 0.00599 1.26E+03 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 1.72E+02 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 118 P237 Position #1 0

7.35E+06 H-3 1.76 1.20E+07 2.33E+08 0.0516 0.3878 3.42E+09 0.0035 0.0264 3.25E+07 0.3698 2.7719 Co-60 0.06431 4.73E+05 1.54E+08 0.0031 2.26E+09 0.0002 2.15E+07 0.0220 Ni-63 442 2.09E+08 3.93E+09 0.0532 5.78E+10 0.0036 5.50E+08 0.3800 Sr-90 0.021 1.43E+05 1.40E+06 0.1024 2.06E+07 0.0070 1.96E+05 0.7317 Cs-134 0.00014 1.00E+03 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 6.83E+06 3.85E+07 0.1774 5.66E+08 0.0121 5.39E+06 1.2670 Eu-152 0.00599 4.41E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0009 Eu-154 0.00082 6.01E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 119 P237 Position #2 1

3.40E+06 H-3 1.76 5.56E+06 2.33E+08 0.0239 0.1794 3.42E+09 0.0016 0.0122 3.25E+07 0.1711 1.2821 Co-60 0.06431 2.19E+05 1.54E+08 0.0014 2.26E+09 0.0001 2.15E+07 0.0102 Ni-63 442 9.67E+07 3.93E+09 0.0246 5.78E+10 0.0017 5.50E+08 0.1758 Sr-90 0.021 6.63E+04 1.40E+06 0.0474 2.06E+07 0.0032 1.96E+05 0.3385 Cs-134 0.00014 4.63E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.16E+06 3.85E+07 0.0821 5.66E+08 0.0056 5.39E+06 0.5861 Eu-152 0.00599 2.04E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.78E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[61]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 120 P237 Position #3 2

2.52E+06 H-3 1.76 4.12E+06 2.33E+08 0.0177 0.1330 3.42E+09 0.0012 0.0090 3.25E+07 0.1268 0.9503 Co-60 0.06431 1.62E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0075 Ni-63 442 7.17E+07 3.93E+09 0.0182 5.78E+10 0.0012 5.50E+08 0.1303 Sr-90 0.021 4.92E+04 1.40E+06 0.0351 2.06E+07 0.0024 1.96E+05 0.2509 Cs-134 0.00014 3.43E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.34E+06 3.85E+07 0.0608 5.66E+08 0.0041 5.39E+06 0.4344 Eu-152 0.00599 1.51E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.06E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 121 P237 Position #4 3

2.45E+06 H-3 1.76 4.01E+06 2.33E+08 0.0172 0.1294 3.42E+09 0.0012 0.0088 3.25E+07 0.1234 0.9245 Co-60 0.06431 1.58E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.97E+07 3.93E+09 0.0177 5.78E+10 0.0012 5.50E+08 0.1267 Sr-90 0.021 4.78E+04 1.40E+06 0.0342 2.06E+07 0.0023 1.96E+05 0.2441 Cs-134 0.00014 3.34E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.28E+06 3.85E+07 0.0592 5.66E+08 0.0040 5.39E+06 0.4226 Eu-152 0.00599 1.47E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.00E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 122 P237 Position #5 4

2.47E+06 H-3 1.76 4.03E+06 2.33E+08 0.0173 0.1300 3.42E+09 0.0012 0.0088 3.25E+07 0.1240 0.9294 Co-60 0.06431 1.59E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0074 Ni-63 442 7.01E+07 3.93E+09 0.0178 5.78E+10 0.0012 5.50E+08 0.1274 Sr-90 0.021 4.81E+04 1.40E+06 0.0343 2.06E+07 0.0023 1.96E+05 0.2454 Cs-134 0.00014 3.36E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.29E+06 3.85E+07 0.0595 5.66E+08 0.0040 5.39E+06 0.4249 Eu-152 0.00599 1.48E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.02E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 123 P237 Position #6 5

2.39E+06 H-3 1.76 3.90E+06 2.33E+08 0.0167 0.1258 3.42E+09 0.0011 0.0086 3.25E+07 0.1200 0.8991 Co-60 0.06431 1.53E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0071 Ni-63 442 6.78E+07 3.93E+09 0.0173 5.78E+10 0.0012 5.50E+08 0.1233 Sr-90 0.021 4.65E+04 1.40E+06 0.0332 2.06E+07 0.0023 1.96E+05 0.2373 Cs-134 0.00014 3.25E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.22E+06 3.85E+07 0.0575 5.66E+08 0.0039 5.39E+06 0.4110 Eu-152 0.00599 1.43E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.95E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 124 P237 Position #7 6

2.33E+06 H-3 1.76 3.81E+06 2.33E+08 0.0163 0.1228 3.42E+09 0.0011 0.0084 3.25E+07 0.1171 0.8779 Co-60 0.06431 1.50E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0070 Ni-63 442 6.62E+07 3.93E+09 0.0168 5.78E+10 0.0011 5.50E+08 0.1204 Sr-90 0.021 4.54E+04 1.40E+06 0.0324 2.06E+07 0.0022 1.96E+05 0.2317 Cs-134 0.00014 3.17E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.16E+06 3.85E+07 0.0562 5.66E+08 0.0038 5.39E+06 0.4013 Eu-152 0.00599 1.40E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.90E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 125 P237 Position #8 7

2.28E+06 H-3 1.76 3.73E+06 2.33E+08 0.0160 0.1205 3.42E+09 0.0011 0.0082 3.25E+07 0.1149 0.8610 Co-60 0.06431 1.47E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0068 Ni-63 442 6.49E+07 3.93E+09 0.0165 5.78E+10 0.0011 5.50E+08 0.1180 Sr-90 0.021 4.45E+04 1.40E+06 0.0318 2.06E+07 0.0022 1.96E+05 0.2273 Cs-134 0.00014 3.11E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.12E+06 3.85E+07 0.0551 5.66E+08 0.0037 5.39E+06 0.3936 Eu-152 0.00599 1.37E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.87E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[62]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 126 P237 Position #9 8

2.39E+06 H-3 1.76 3.90E+06 2.33E+08 0.0167 0.1259 3.42E+09 0.0011 0.0086 3.25E+07 0.1200 0.8997 Co-60 0.06431 1.53E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0071 Ni-63 442 6.78E+07 3.93E+09 0.0173 5.78E+10 0.0012 5.50E+08 0.1233 Sr-90 0.021 4.66E+04 1.40E+06 0.0333 2.06E+07 0.0023 1.96E+05 0.2375 Cs-134 0.00014 3.25E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.22E+06 3.85E+07 0.0576 5.66E+08 0.0039 5.39E+06 0.4113 Eu-152 0.00599 1.43E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.95E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 127 P237 Position #10 9

2.30E+06 H-3 1.76 3.76E+06 2.33E+08 0.0162 0.1214 3.42E+09 0.0011 0.0083 3.25E+07 0.1158 0.8679 Co-60 0.06431 1.48E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0069 Ni-63 442 6.54E+07 3.93E+09 0.0167 5.78E+10 0.0011 5.50E+08 0.1190 Sr-90 0.021 4.49E+04 1.40E+06 0.0321 2.06E+07 0.0022 1.96E+05 0.2291 Cs-134 0.00014 3.14E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.14E+06 3.85E+07 0.0555 5.66E+08 0.0038 5.39E+06 0.3967 Eu-152 0.00599 1.38E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.88E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 128 P237 Position #11 10 2.28E+06 H-3 1.76 3.72E+06 2.33E+08 0.0160 0.1202 3.42E+09 0.0011 0.0082 3.25E+07 0.1146 0.8589 Co-60 0.06431 1.47E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0068 Ni-63 442 6.48E+07 3.93E+09 0.0165 5.78E+10 0.0011 5.50E+08 0.1177 Sr-90 0.021 4.44E+04 1.40E+06 0.0317 2.06E+07 0.0022 1.96E+05 0.2267 Cs-134 0.00014 3.10E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.12E+06 3.85E+07 0.0550 5.66E+08 0.0037 5.39E+06 0.3926 Eu-152 0.00599 1.37E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.86E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 129 P237 Position #12 11 2.36E+06 H-3 1.76 3.85E+06 2.33E+08 0.0165 0.1243 3.42E+09 0.0011 0.0085 3.25E+07 0.1185 0.8883 Co-60 0.06431 1.52E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0070 Ni-63 442 6.70E+07 3.93E+09 0.0170 5.78E+10 0.0012 5.50E+08 0.1218 Sr-90 0.021 4.60E+04 1.40E+06 0.0328 2.06E+07 0.0022 1.96E+05 0.2345 Cs-134 0.00014 3.21E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.19E+06 3.85E+07 0.0568 5.66E+08 0.0039 5.39E+06 0.4060 Eu-152 0.00599 1.41E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.93E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 130 P237 Position #13 12 2.36E+06 H-3 1.76 3.86E+06 2.33E+08 0.0166 0.1246 3.42E+09 0.0011 0.0085 3.25E+07 0.1188 0.8905 Co-60 0.06431 1.52E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0071 Ni-63 442 6.71E+07 3.93E+09 0.0171 5.78E+10 0.0012 5.50E+08 0.1221 Sr-90 0.021 4.61E+04 1.40E+06 0.0329 2.06E+07 0.0022 1.96E+05 0.2351 Cs-134 0.00014 3.22E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.19E+06 3.85E+07 0.0570 5.66E+08 0.0039 5.39E+06 0.4070 Eu-152 0.00599 1.42E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.93E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 131 P237 Position #14 13 2.31E+06 H-3 1.76 3.77E+06 2.33E+08 0.0162 0.1217 3.42E+09 0.0011 0.0083 3.25E+07 0.1161 0.8698 Co-60 0.06431 1.48E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0069 Ni-63 442 6.56E+07 3.93E+09 0.0167 5.78E+10 0.0011 5.50E+08 0.1192 Sr-90 0.021 4.50E+04 1.40E+06 0.0321 2.06E+07 0.0022 1.96E+05 0.2296 Cs-134 0.00014 3.14E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.14E+06 3.85E+07 0.0557 5.66E+08 0.0038 5.39E+06 0.3976 Eu-152 0.00599 1.38E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.89E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[63]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 132 P237 Position #15 14 2.40E+06 H-3 1.76 3.92E+06 2.33E+08 0.0168 0.1264 3.42E+09 0.0011 0.0086 3.25E+07 0.1205 0.9032 Co-60 0.06431 1.54E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0072 Ni-63 442 6.81E+07 3.93E+09 0.0173 5.78E+10 0.0012 5.50E+08 0.1238 Sr-90 0.021 4.67E+04 1.40E+06 0.0334 2.06E+07 0.0023 1.96E+05 0.2384 Cs-134 0.00014 3.26E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.23E+06 3.85E+07 0.0578 5.66E+08 0.0039 5.39E+06 0.4129 Eu-152 0.00599 1.44E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.96E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 133 P237 Position #16 15 2.29E+06 H-3 1.76 3.75E+06 2.33E+08 0.0161 0.1209 3.42E+09 0.0011 0.0082 3.25E+07 0.1153 0.8641 Co-60 0.06431 1.47E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0069 Ni-63 442 6.52E+07 3.93E+09 0.0166 5.78E+10 0.0011 5.50E+08 0.1185 Sr-90 0.021 4.47E+04 1.40E+06 0.0319 2.06E+07 0.0022 1.96E+05 0.2281 Cs-134 0.00014 3.12E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.13E+06 3.85E+07 0.0553 5.66E+08 0.0038 5.39E+06 0.3950 Eu-152 0.00599 1.37E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.87E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 134 P237 Position #17 16 2.35E+06 H-3 1.76 3.84E+06 2.33E+08 0.0165 0.1239 3.42E+09 0.0011 0.0084 3.25E+07 0.1182 0.8857 Co-60 0.06431 1.51E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0070 Ni-63 442 6.68E+07 3.93E+09 0.0170 5.78E+10 0.0012 5.50E+08 0.1214 Sr-90 0.021 4.58E+04 1.40E+06 0.0327 2.06E+07 0.0022 1.96E+05 0.2338 Cs-134 0.00014 3.20E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.18E+06 3.85E+07 0.0567 5.66E+08 0.0039 5.39E+06 0.4049 Eu-152 0.00599 1.41E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.92E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 135 P237 Position #18 17 2.48E+06 H-3 1.76 4.05E+06 2.33E+08 0.0174 0.1307 3.42E+09 0.0012 0.0089 3.25E+07 0.1246 0.9341 Co-60 0.06431 1.59E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0074 Ni-63 442 7.04E+07 3.93E+09 0.0179 5.78E+10 0.0012 5.50E+08 0.1281 Sr-90 0.021 4.83E+04 1.40E+06 0.0345 2.06E+07 0.0023 1.96E+05 0.2466 Cs-134 0.00014 3.38E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.30E+06 3.85E+07 0.0598 5.66E+08 0.0041 5.39E+06 0.4270 Eu-152 0.00599 1.49E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.03E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 136 P237 Position #19 18 2.41E+06 H-3 1.76 3.93E+06 2.33E+08 0.0169 0.1269 3.42E+09 0.0011 0.0086 3.25E+07 0.1210 0.9067 Co-60 0.06431 1.55E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0072 Ni-63 442 6.84E+07 3.93E+09 0.0174 5.78E+10 0.0012 5.50E+08 0.1243 Sr-90 0.021 4.69E+04 1.40E+06 0.0335 2.06E+07 0.0023 1.96E+05 0.2393 Cs-134 0.00014 3.28E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.23E+06 3.85E+07 0.0580 5.66E+08 0.0039 5.39E+06 0.4145 Eu-152 0.00599 1.44E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.97E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 137 P237 Position #20 19 2.23E+06 H-3 1.76 3.65E+06 2.33E+08 0.0157 0.1177 3.42E+09 0.0011 0.0080 3.25E+07 0.1122 0.8410 Co-60 0.06431 1.43E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0067 Ni-63 442 6.34E+07 3.93E+09 0.0161 5.78E+10 0.0011 5.50E+08 0.1153 Sr-90 0.021 4.35E+04 1.40E+06 0.0311 2.06E+07 0.0021 1.96E+05 0.2220 Cs-134 0.00014 3.04E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.07E+06 3.85E+07 0.0538 5.66E+08 0.0037 5.39E+06 0.3844 Eu-152 0.00599 1.34E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.82E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[64]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 138 P237 Position #21 20 2.03E+06 H-3 1.76 3.33E+06 2.33E+08 0.0143 0.1073 3.42E+09 0.0010 0.0073 3.25E+07 0.1023 0.7671 Co-60 0.06431 1.31E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.78E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1052 Sr-90 0.021 3.97E+04 1.40E+06 0.0283 2.06E+07 0.0019 1.96E+05 0.2025 Cs-134 0.00014 2.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0491 5.66E+08 0.0033 5.39E+06 0.3506 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 139 P237 Position #22 21 2.05E+06 H-3 1.76 3.35E+06 2.33E+08 0.0144 0.1081 3.42E+09 0.0010 0.0074 3.25E+07 0.1030 0.7723 Co-60 0.06431 1.32E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.82E+07 3.93E+09 0.0148 5.78E+10 0.0010 5.50E+08 0.1059 Sr-90 0.021 4.00E+04 1.40E+06 0.0285 2.06E+07 0.0019 1.96E+05 0.2039 Cs-134 0.00014 2.79E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.90E+06 3.85E+07 0.0494 5.66E+08 0.0034 5.39E+06 0.3530 Eu-152 0.00599 1.23E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.67E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 140 P237 Position #23 22 2.02E+06 H-3 1.76 3.30E+06 2.33E+08 0.0142 0.1064 3.42E+09 0.0010 0.0072 3.25E+07 0.1014 0.7603 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.73E+07 3.93E+09 0.0146 5.78E+10 0.0010 5.50E+08 0.1042 Sr-90 0.021 3.93E+04 1.40E+06 0.0281 2.06E+07 0.0019 1.96E+05 0.2007 Cs-134 0.00014 2.75E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.87E+06 3.85E+07 0.0487 5.66E+08 0.0033 5.39E+06 0.3475 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.65E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 141 P237 Position #24 23 1.95E+06 H-3 1.76 3.19E+06 2.33E+08 0.0137 0.1029 3.42E+09 0.0009 0.0070 3.25E+07 0.0981 0.7354 Co-60 0.06431 1.25E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0058 Ni-63 442 5.54E+07 3.93E+09 0.0141 5.78E+10 0.0010 5.50E+08 0.1008 Sr-90 0.021 3.80E+04 1.40E+06 0.0272 2.06E+07 0.0018 1.96E+05 0.1941 Cs-134 0.00014 2.66E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.81E+06 3.85E+07 0.0471 5.66E+08 0.0032 5.39E+06 0.3361 Eu-152 0.00599 1.17E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.59E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 142 P237 Position #25 24 2.02E+06 H-3 1.76 3.30E+06 2.33E+08 0.0142 0.1066 3.42E+09 0.0010 0.0073 3.25E+07 0.1017 0.7620 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.75E+07 3.93E+09 0.0146 5.78E+10 0.0010 5.50E+08 0.1045 Sr-90 0.021 3.94E+04 1.40E+06 0.0282 2.06E+07 0.0019 1.96E+05 0.2011 Cs-134 0.00014 2.75E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.88E+06 3.85E+07 0.0488 5.66E+08 0.0033 5.39E+06 0.3483 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.65E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 143 P237 Position #26 25 1.96E+06 H-3 1.76 3.21E+06 2.33E+08 0.0138 0.1036 3.42E+09 0.0009 0.0070 3.25E+07 0.0988 0.7404 Co-60 0.06431 1.26E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.58E+07 3.93E+09 0.0142 5.78E+10 0.0010 5.50E+08 0.1015 Sr-90 0.021 3.83E+04 1.40E+06 0.0274 2.06E+07 0.0019 1.96E+05 0.1954 Cs-134 0.00014 2.68E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.82E+06 3.85E+07 0.0474 5.66E+08 0.0032 5.39E+06 0.3384 Eu-152 0.00599 1.18E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.61E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[65]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 144 P237 Position #27 26 2.02E+06 H-3 1.76 3.30E+06 2.33E+08 0.0141 0.1064 3.42E+09 0.0010 0.0072 3.25E+07 0.1014 0.7601 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.73E+07 3.93E+09 0.0146 5.78E+10 0.0010 5.50E+08 0.1042 Sr-90 0.021 3.93E+04 1.40E+06 0.0281 2.06E+07 0.0019 1.96E+05 0.2006 Cs-134 0.00014 2.75E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.87E+06 3.85E+07 0.0486 5.66E+08 0.0033 5.39E+06 0.3474 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.65E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 145 P237 Position #28 27 2.02E+06 H-3 1.76 3.31E+06 2.33E+08 0.0142 0.1068 3.42E+09 0.0010 0.0073 3.25E+07 0.1018 0.7632 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.75E+07 3.93E+09 0.0146 5.78E+10 0.0010 5.50E+08 0.1046 Sr-90 0.021 3.95E+04 1.40E+06 0.0282 2.06E+07 0.0019 1.96E+05 0.2015 Cs-134 0.00014 2.76E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.88E+06 3.85E+07 0.0488 5.66E+08 0.0033 5.39E+06 0.3489 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 146 P237 Position #29 28 2.03E+06 H-3 1.76 3.32E+06 2.33E+08 0.0143 0.1072 3.42E+09 0.0010 0.0073 3.25E+07 0.1023 0.7664 Co-60 0.06431 1.31E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.78E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1051 Sr-90 0.021 3.97E+04 1.40E+06 0.0283 2.06E+07 0.0019 1.96E+05 0.2023 Cs-134 0.00014 2.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0490 5.66E+08 0.0033 5.39E+06 0.3503 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 147 P237 Position #30 29 1.98E+06 H-3 1.76 3.24E+06 2.33E+08 0.0139 0.1046 3.42E+09 0.0009 0.0071 3.25E+07 0.0997 0.7476 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.64E+07 3.93E+09 0.0143 5.78E+10 0.0010 5.50E+08 0.1025 Sr-90 0.021 3.87E+04 1.40E+06 0.0276 2.06E+07 0.0019 1.96E+05 0.1974 Cs-134 0.00014 2.70E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.84E+06 3.85E+07 0.0478 5.66E+08 0.0033 5.39E+06 0.3417 Eu-152 0.00599 1.19E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.62E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 148 P237 Position #31 30 1.98E+06 H-3 1.76 3.24E+06 2.33E+08 0.0139 0.1046 3.42E+09 0.0009 0.0071 3.25E+07 0.0997 0.7476 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.64E+07 3.93E+09 0.0143 5.78E+10 0.0010 5.50E+08 0.1025 Sr-90 0.021 3.87E+04 1.40E+06 0.0276 2.06E+07 0.0019 1.96E+05 0.1974 Cs-134 0.00014 2.70E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.84E+06 3.85E+07 0.0478 5.66E+08 0.0033 5.39E+06 0.3417 Eu-152 0.00599 1.19E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.62E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 149 P237 Position #32 31 1.99E+06 H-3 1.76 3.26E+06 2.33E+08 0.0140 0.1052 3.42E+09 0.0010 0.0072 3.25E+07 0.1003 0.7519 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.67E+07 3.93E+09 0.0144 5.78E+10 0.0010 5.50E+08 0.1031 Sr-90 0.021 3.89E+04 1.40E+06 0.0278 2.06E+07 0.0019 1.96E+05 0.1985 Cs-134 0.00014 2.72E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.85E+06 3.85E+07 0.0481 5.66E+08 0.0033 5.39E+06 0.3437 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.63E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[66]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 150 P237 Position #33 32 1.97E+06 H-3 1.76 3.23E+06 2.33E+08 0.0138 0.1041 3.42E+09 0.0009 0.0071 3.25E+07 0.0993 0.7441 Co-60 0.06431 1.27E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.61E+07 3.93E+09 0.0143 5.78E+10 0.0010 5.50E+08 0.1020 Sr-90 0.021 3.85E+04 1.40E+06 0.0275 2.06E+07 0.0019 1.96E+05 0.1964 Cs-134 0.00014 2.69E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.83E+06 3.85E+07 0.0476 5.66E+08 0.0032 5.39E+06 0.3401 Eu-152 0.00599 1.18E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.61E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 151 P237 Position #34 33 1.97E+06 H-3 1.76 3.22E+06 2.33E+08 0.0138 0.1039 3.42E+09 0.0009 0.0071 3.25E+07 0.0991 0.7426 Co-60 0.06431 1.27E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.60E+07 3.93E+09 0.0142 5.78E+10 0.0010 5.50E+08 0.1018 Sr-90 0.021 3.84E+04 1.40E+06 0.0274 2.06E+07 0.0019 1.96E+05 0.1960 Cs-134 0.00014 2.68E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.83E+06 3.85E+07 0.0475 5.66E+08 0.0032 5.39E+06 0.3394 Eu-152 0.00599 1.18E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.61E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 152 P237 Position #35 34 1.98E+06 H-3 1.76 3.24E+06 2.33E+08 0.0139 0.1044 3.42E+09 0.0009 0.0071 3.25E+07 0.0995 0.7461 Co-60 0.06431 1.27E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.63E+07 3.93E+09 0.0143 5.78E+10 0.0010 5.50E+08 0.1023 Sr-90 0.021 3.86E+04 1.40E+06 0.0276 2.06E+07 0.0019 1.96E+05 0.1970 Cs-134 0.00014 2.70E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.84E+06 3.85E+07 0.0477 5.66E+08 0.0032 5.39E+06 0.3410 Eu-152 0.00599 1.19E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.62E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 153 P237 Position #36 35 2.00E+06 H-3 1.76 3.27E+06 2.33E+08 0.0141 0.1057 3.42E+09 0.0010 0.0072 3.25E+07 0.1008 0.7552 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.69E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1035 Sr-90 0.021 3.91E+04 1.40E+06 0.0279 2.06E+07 0.0019 1.96E+05 0.1994 Cs-134 0.00014 2.73E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.86E+06 3.85E+07 0.0483 5.66E+08 0.0033 5.39E+06 0.3452 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 154 P237 Position #37 36 1.99E+06 H-3 1.76 3.26E+06 2.33E+08 0.0140 0.1051 3.42E+09 0.0010 0.0072 3.25E+07 0.1003 0.7515 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.67E+07 3.93E+09 0.0144 5.78E+10 0.0010 5.50E+08 0.1030 Sr-90 0.021 3.89E+04 1.40E+06 0.0278 2.06E+07 0.0019 1.96E+05 0.1984 Cs-134 0.00014 2.72E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.85E+06 3.85E+07 0.0481 5.66E+08 0.0033 5.39E+06 0.3435 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.63E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 155 P237 Position #38 37 1.98E+06 H-3 1.76 3.24E+06 2.33E+08 0.0139 0.1045 3.42E+09 0.0009 0.0071 3.25E+07 0.0996 0.7466 Co-60 0.06431 1.27E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.63E+07 3.93E+09 0.0143 5.78E+10 0.0010 5.50E+08 0.1023 Sr-90 0.021 3.86E+04 1.40E+06 0.0276 2.06E+07 0.0019 1.96E+05 0.1971 Cs-134 0.00014 2.70E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.84E+06 3.85E+07 0.0478 5.66E+08 0.0032 5.39E+06 0.3413 Eu-152 0.00599 1.19E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.62E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[67]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 156 P237 Position #39 38 2.04E+06 H-3 1.76 3.33E+06 2.33E+08 0.0143 0.1074 3.42E+09 0.0010 0.0073 3.25E+07 0.1024 0.7676 Co-60 0.06431 1.31E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.79E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1052 Sr-90 0.021 3.97E+04 1.40E+06 0.0284 2.06E+07 0.0019 1.96E+05 0.2026 Cs-134 0.00014 2.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0491 5.66E+08 0.0033 5.39E+06 0.3509 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 157 P237 Position #40 39 1.97E+06 H-3 1.76 3.22E+06 2.33E+08 0.0138 0.1039 3.42E+09 0.0009 0.0071 3.25E+07 0.0991 0.7426 Co-60 0.06431 1.27E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.60E+07 3.93E+09 0.0142 5.78E+10 0.0010 5.50E+08 0.1018 Sr-90 0.021 3.84E+04 1.40E+06 0.0274 2.06E+07 0.0019 1.96E+05 0.1960 Cs-134 0.00014 2.68E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.83E+06 3.85E+07 0.0475 5.66E+08 0.0032 5.39E+06 0.3394 Eu-152 0.00599 1.18E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.61E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 158 P237 Position #41 40 2.01E+06 H-3 1.76 3.28E+06 2.33E+08 0.0141 0.1059 3.42E+09 0.0010 0.0072 3.25E+07 0.1010 0.7568 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.71E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1038 Sr-90 0.021 3.92E+04 1.40E+06 0.0280 2.06E+07 0.0019 1.96E+05 0.1998 Cs-134 0.00014 2.74E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.86E+06 3.85E+07 0.0484 5.66E+08 0.0033 5.39E+06 0.3459 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 159 P237 Position #42 41 2.00E+06 H-3 1.76 3.26E+06 2.33E+08 0.0140 0.1053 3.42E+09 0.0010 0.0072 3.25E+07 0.1004 0.7523 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.67E+07 3.93E+09 0.0144 5.78E+10 0.0010 5.50E+08 0.1031 Sr-90 0.021 3.89E+04 1.40E+06 0.0278 2.06E+07 0.0019 1.96E+05 0.1986 Cs-134 0.00014 2.72E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.85E+06 3.85E+07 0.0481 5.66E+08 0.0033 5.39E+06 0.3439 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.63E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 160 P237 Position #43 42 2.01E+06 H-3 1.76 3.28E+06 2.33E+08 0.0141 0.1058 3.42E+09 0.0010 0.0072 3.25E+07 0.1009 0.7564 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.70E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1037 Sr-90 0.021 3.91E+04 1.40E+06 0.0280 2.06E+07 0.0019 1.96E+05 0.1997 Cs-134 0.00014 2.73E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.86E+06 3.85E+07 0.0484 5.66E+08 0.0033 5.39E+06 0.3457 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 161 P237 Position #44 43 1.99E+06 H-3 1.76 3.25E+06 2.33E+08 0.0139 0.1047 3.42E+09 0.0009 0.0071 3.25E+07 0.0999 0.7484 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.64E+07 3.93E+09 0.0144 5.78E+10 0.0010 5.50E+08 0.1026 Sr-90 0.021 3.87E+04 1.40E+06 0.0277 2.06E+07 0.0019 1.96E+05 0.1976 Cs-134 0.00014 2.70E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.84E+06 3.85E+07 0.0479 5.66E+08 0.0033 5.39E+06 0.3421 Eu-152 0.00599 1.19E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.62E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[68]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 162 P237 Position #45 44 2.07E+06 H-3 1.76 3.38E+06 2.33E+08 0.0145 0.1089 3.42E+09 0.0010 0.0074 3.25E+07 0.1039 0.7786 Co-60 0.06431 1.33E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.87E+07 3.93E+09 0.0149 5.78E+10 0.0010 5.50E+08 0.1067 Sr-90 0.021 4.03E+04 1.40E+06 0.0288 2.06E+07 0.0020 1.96E+05 0.2055 Cs-134 0.00014 2.81E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.92E+06 3.85E+07 0.0498 5.66E+08 0.0034 5.39E+06 0.3559 Eu-152 0.00599 1.24E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.69E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 163 P237 Position #46 45 2.00E+06 H-3 1.76 3.26E+06 2.33E+08 0.0140 0.1052 3.42E+09 0.0010 0.0072 3.25E+07 0.1003 0.7520 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.67E+07 3.93E+09 0.0144 5.78E+10 0.0010 5.50E+08 0.1031 Sr-90 0.021 3.89E+04 1.40E+06 0.0278 2.06E+07 0.0019 1.96E+05 0.1985 Cs-134 0.00014 2.72E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.85E+06 3.85E+07 0.0481 5.66E+08 0.0033 5.39E+06 0.3438 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.63E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 164 P237 Position #47 46 2.04E+06 H-3 1.76 3.33E+06 2.33E+08 0.0143 0.1074 3.42E+09 0.0010 0.0073 3.25E+07 0.1024 0.7676 Co-60 0.06431 1.31E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.79E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1052 Sr-90 0.021 3.97E+04 1.40E+06 0.0284 2.06E+07 0.0019 1.96E+05 0.2026 Cs-134 0.00014 2.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0491 5.66E+08 0.0033 5.39E+06 0.3509 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 165 P237 Position #48 47 2.04E+06 H-3 1.76 3.34E+06 2.33E+08 0.0143 0.1078 3.42E+09 0.0010 0.0073 3.25E+07 0.1028 0.7702 Co-60 0.06431 1.31E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.81E+07 3.93E+09 0.0148 5.78E+10 0.0010 5.50E+08 0.1056 Sr-90 0.021 3.99E+04 1.40E+06 0.0285 2.06E+07 0.0019 1.96E+05 0.2033 Cs-134 0.00014 2.78E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.90E+06 3.85E+07 0.0493 5.66E+08 0.0034 5.39E+06 0.3521 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.67E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 166 P237 Position #49 48 1.98E+06 H-3 1.76 3.23E+06 2.33E+08 0.0139 0.1042 3.42E+09 0.0009 0.0071 3.25E+07 0.0994 0.7448 Co-60 0.06431 1.27E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.62E+07 3.93E+09 0.0143 5.78E+10 0.0010 5.50E+08 0.1021 Sr-90 0.021 3.85E+04 1.40E+06 0.0275 2.06E+07 0.0019 1.96E+05 0.1966 Cs-134 0.00014 2.69E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.84E+06 3.85E+07 0.0477 5.66E+08 0.0032 5.39E+06 0.3405 Eu-152 0.00599 1.18E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.62E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 167 P237 Position #50 49 2.00E+06 H-3 1.76 3.27E+06 2.33E+08 0.0140 0.1055 3.42E+09 0.0010 0.0072 3.25E+07 0.1006 0.7541 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.69E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1034 Sr-90 0.021 3.90E+04 1.40E+06 0.0279 2.06E+07 0.0019 1.96E+05 0.1991 Cs-134 0.00014 2.73E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.86E+06 3.85E+07 0.0483 5.66E+08 0.0033 5.39E+06 0.3447 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[69]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 168 P236 Position #1 0

6.38E+06 H-3 1.76 1.04E+07 2.33E+08 0.0448 0.3366 3.42E+09 0.0030 0.0229 3.25E+07 0.3209 2.4053 Co-60 0.06431 4.10E+05 1.54E+08 0.0027 2.26E+09 0.0002 2.15E+07 0.0191 Ni-63 442 1.81E+08 3.93E+09 0.0461 5.78E+10 0.0031 5.50E+08 0.3297 Sr-90 0.021 1.24E+05 1.40E+06 0.0889 2.06E+07 0.0060 1.96E+05 0.6349 Cs-134 0.00014 8.69E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 5.93E+06 3.85E+07 0.1539 5.66E+08 0.0105 5.39E+06 1.0995 Eu-152 0.00599 3.83E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0008 Eu-154 0.00082 5.22E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 169 P236 Position #2 1

3.41E+06 H-3 1.76 5.58E+06 2.33E+08 0.0240 0.1801 3.42E+09 0.0016 0.0122 3.25E+07 0.1717 1.2871 Co-60 0.06431 2.20E+05 1.54E+08 0.0014 2.26E+09 0.0001 2.15E+07 0.0102 Ni-63 442 9.71E+07 3.93E+09 0.0247 5.78E+10 0.0017 5.50E+08 0.1765 Sr-90 0.021 6.66E+04 1.40E+06 0.0476 2.06E+07 0.0032 1.96E+05 0.3398 Cs-134 0.00014 4.65E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.17E+06 3.85E+07 0.0824 5.66E+08 0.0056 5.39E+06 0.5884 Eu-152 0.00599 2.05E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.79E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 170 P236 Position #3 2

2.45E+06 H-3 1.76 4.00E+06 2.33E+08 0.0172 0.1292 3.42E+09 0.0012 0.0088 3.25E+07 0.1232 0.9233 Co-60 0.06431 1.57E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.96E+07 3.93E+09 0.0177 5.78E+10 0.0012 5.50E+08 0.1266 Sr-90 0.021 4.78E+04 1.40E+06 0.0341 2.06E+07 0.0023 1.96E+05 0.2437 Cs-134 0.00014 3.34E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.27E+06 3.85E+07 0.0591 5.66E+08 0.0040 5.39E+06 0.4220 Eu-152 0.00599 1.47E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.00E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 171 P236 Position #4 3

2.43E+06 H-3 1.76 3.96E+06 2.33E+08 0.0170 0.1279 3.42E+09 0.0012 0.0087 3.25E+07 0.1220 0.9142 Co-60 0.06431 1.56E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.89E+07 3.93E+09 0.0175 5.78E+10 0.0012 5.50E+08 0.1253 Sr-90 0.021 4.73E+04 1.40E+06 0.0338 2.06E+07 0.0023 1.96E+05 0.2413 Cs-134 0.00014 3.30E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.25E+06 3.85E+07 0.0585 5.66E+08 0.0040 5.39E+06 0.4179 Eu-152 0.00599 1.45E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.98E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 172 P236 Position #5 4

2.41E+06 H-3 1.76 3.93E+06 2.33E+08 0.0169 0.1269 3.42E+09 0.0012 0.0086 3.25E+07 0.1210 0.9072 Co-60 0.06431 1.55E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0072 Ni-63 442 6.84E+07 3.93E+09 0.0174 5.78E+10 0.0012 5.50E+08 0.1244 Sr-90 0.021 4.69E+04 1.40E+06 0.0335 2.06E+07 0.0023 1.96E+05 0.2395 Cs-134 0.00014 3.28E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.24E+06 3.85E+07 0.0581 5.66E+08 0.0039 5.39E+06 0.4147 Eu-152 0.00599 1.44E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.97E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 173 P236 Position #6 5

2.34E+06 H-3 1.76 3.82E+06 2.33E+08 0.0164 0.1234 3.42E+09 0.0011 0.0084 3.25E+07 0.1177 0.8820 Co-60 0.06431 1.50E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0070 Ni-63 442 6.65E+07 3.93E+09 0.0169 5.78E+10 0.0012 5.50E+08 0.1209 Sr-90 0.021 4.56E+04 1.40E+06 0.0326 2.06E+07 0.0022 1.96E+05 0.2328 Cs-134 0.00014 3.19E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.17E+06 3.85E+07 0.0564 5.66E+08 0.0038 5.39E+06 0.4032 Eu-152 0.00599 1.40E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.91E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[70]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 174 P236 Position #7 6

2.23E+06 H-3 1.76 3.65E+06 2.33E+08 0.0157 0.1179 3.42E+09 0.0011 0.0080 3.25E+07 0.1124 0.8423 Co-60 0.06431 1.44E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0067 Ni-63 442 6.35E+07 3.93E+09 0.0162 5.78E+10 0.0011 5.50E+08 0.1155 Sr-90 0.021 4.36E+04 1.40E+06 0.0311 2.06E+07 0.0021 1.96E+05 0.2224 Cs-134 0.00014 3.04E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.08E+06 3.85E+07 0.0539 5.66E+08 0.0037 5.39E+06 0.3850 Eu-152 0.00599 1.34E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.83E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 175 P236 Position #8 7

2.22E+06 H-3 1.76 3.63E+06 2.33E+08 0.0156 0.1173 3.42E+09 0.0011 0.0080 3.25E+07 0.1118 0.8380 Co-60 0.06431 1.43E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0066 Ni-63 442 6.32E+07 3.93E+09 0.0161 5.78E+10 0.0011 5.50E+08 0.1149 Sr-90 0.021 4.34E+04 1.40E+06 0.0310 2.06E+07 0.0021 1.96E+05 0.2212 Cs-134 0.00014 3.03E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.06E+06 3.85E+07 0.0536 5.66E+08 0.0036 5.39E+06 0.3831 Eu-152 0.00599 1.33E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.82E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 176 P236 Position #9 8

2.19E+06 H-3 1.76 3.58E+06 2.33E+08 0.0154 0.1155 3.42E+09 0.0010 0.0079 3.25E+07 0.1101 0.8255 Co-60 0.06431 1.41E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0066 Ni-63 442 6.22E+07 3.93E+09 0.0158 5.78E+10 0.0011 5.50E+08 0.1132 Sr-90 0.021 4.27E+04 1.40E+06 0.0305 2.06E+07 0.0021 1.96E+05 0.2179 Cs-134 0.00014 2.98E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.03E+06 3.85E+07 0.0528 5.66E+08 0.0036 5.39E+06 0.3774 Eu-152 0.00599 1.31E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.79E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 177 P236 Position #10 9

2.22E+06 H-3 1.76 3.62E+06 2.33E+08 0.0156 0.1169 3.42E+09 0.0011 0.0080 3.25E+07 0.1115 0.8358 Co-60 0.06431 1.43E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0066 Ni-63 442 6.30E+07 3.93E+09 0.0160 5.78E+10 0.0011 5.50E+08 0.1146 Sr-90 0.021 4.32E+04 1.40E+06 0.0309 2.06E+07 0.0021 1.96E+05 0.2206 Cs-134 0.00014 3.02E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.06E+06 3.85E+07 0.0535 5.66E+08 0.0036 5.39E+06 0.3820 Eu-152 0.00599 1.33E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.81E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 178 P236 Position #11 10 2.15E+06 H-3 1.76 3.51E+06 2.33E+08 0.0151 0.1132 3.42E+09 0.0010 0.0077 3.25E+07 0.1080 0.8092 Co-60 0.06431 1.38E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0064 Ni-63 442 6.10E+07 3.93E+09 0.0155 5.78E+10 0.0011 5.50E+08 0.1109 Sr-90 0.021 4.19E+04 1.40E+06 0.0299 2.06E+07 0.0020 1.96E+05 0.2136 Cs-134 0.00014 2.92E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.99E+06 3.85E+07 0.0518 5.66E+08 0.0035 5.39E+06 0.3699 Eu-152 0.00599 1.29E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.75E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 179 P236 Position #12 11 2.20E+06 H-3 1.76 3.59E+06 2.33E+08 0.0154 0.1158 3.42E+09 0.0010 0.0079 3.25E+07 0.1105 0.8278 Co-60 0.06431 1.41E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0066 Ni-63 442 6.24E+07 3.93E+09 0.0159 5.78E+10 0.0011 5.50E+08 0.1135 Sr-90 0.021 4.28E+04 1.40E+06 0.0306 2.06E+07 0.0021 1.96E+05 0.2185 Cs-134 0.00014 2.99E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.04E+06 3.85E+07 0.0530 5.66E+08 0.0036 5.39E+06 0.3784 Eu-152 0.00599 1.32E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.80E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[71]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 180 P236 Position #13 12 2.22E+06 H-3 1.76 3.62E+06 2.33E+08 0.0156 0.1169 3.42E+09 0.0011 0.0080 3.25E+07 0.1115 0.8355 Co-60 0.06431 1.43E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0066 Ni-63 442 6.30E+07 3.93E+09 0.0160 5.78E+10 0.0011 5.50E+08 0.1145 Sr-90 0.021 4.32E+04 1.40E+06 0.0309 2.06E+07 0.0021 1.96E+05 0.2206 Cs-134 0.00014 3.02E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.06E+06 3.85E+07 0.0535 5.66E+08 0.0036 5.39E+06 0.3819 Eu-152 0.00599 1.33E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.81E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 181 P236 Position #14 13 2.18E+06 H-3 1.76 3.56E+06 2.33E+08 0.0153 0.1148 3.42E+09 0.0010 0.0078 3.25E+07 0.1095 0.8205 Co-60 0.06431 1.40E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0065 Ni-63 442 6.19E+07 3.93E+09 0.0157 5.78E+10 0.0011 5.50E+08 0.1125 Sr-90 0.021 4.25E+04 1.40E+06 0.0303 2.06E+07 0.0021 1.96E+05 0.2166 Cs-134 0.00014 2.97E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.02E+06 3.85E+07 0.0525 5.66E+08 0.0036 5.39E+06 0.3751 Eu-152 0.00599 1.30E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.78E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 182 P236 Position #15 14 2.19E+06 H-3 1.76 3.58E+06 2.33E+08 0.0154 0.1155 3.42E+09 0.0010 0.0079 3.25E+07 0.1101 0.8254 Co-60 0.06431 1.41E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0065 Ni-63 442 6.22E+07 3.93E+09 0.0158 5.78E+10 0.0011 5.50E+08 0.1132 Sr-90 0.021 4.27E+04 1.40E+06 0.0305 2.06E+07 0.0021 1.96E+05 0.2179 Cs-134 0.00014 2.98E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.03E+06 3.85E+07 0.0528 5.66E+08 0.0036 5.39E+06 0.3773 Eu-152 0.00599 1.31E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.79E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 183 P236 Position #16 15 2.21E+06 H-3 1.76 3.61E+06 2.33E+08 0.0155 0.1166 3.42E+09 0.0011 0.0079 3.25E+07 0.1112 0.8331 Co-60 0.06431 1.42E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0066 Ni-63 442 6.28E+07 3.93E+09 0.0160 5.78E+10 0.0011 5.50E+08 0.1142 Sr-90 0.021 4.31E+04 1.40E+06 0.0308 2.06E+07 0.0021 1.96E+05 0.2199 Cs-134 0.00014 3.01E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.05E+06 3.85E+07 0.0533 5.66E+08 0.0036 5.39E+06 0.3808 Eu-152 0.00599 1.32E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.81E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 184 P236 Position #17 16 2.22E+06 H-3 1.76 3.63E+06 2.33E+08 0.0156 0.1172 3.42E+09 0.0011 0.0080 3.25E+07 0.1117 0.8375 Co-60 0.06431 1.43E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0066 Ni-63 442 6.32E+07 3.93E+09 0.0161 5.78E+10 0.0011 5.50E+08 0.1148 Sr-90 0.021 4.33E+04 1.40E+06 0.0310 2.06E+07 0.0021 1.96E+05 0.2211 Cs-134 0.00014 3.03E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.06E+06 3.85E+07 0.0536 5.66E+08 0.0036 5.39E+06 0.3828 Eu-152 0.00599 1.33E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.82E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 185 P236 Position #18 17 2.24E+06 H-3 1.76 3.66E+06 2.33E+08 0.0157 0.1182 3.42E+09 0.0011 0.0080 3.25E+07 0.1127 0.8450 Co-60 0.06431 1.44E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0067 Ni-63 442 6.37E+07 3.93E+09 0.0162 5.78E+10 0.0011 5.50E+08 0.1158 Sr-90 0.021 4.37E+04 1.40E+06 0.0312 2.06E+07 0.0021 1.96E+05 0.2231 Cs-134 0.00014 3.05E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.08E+06 3.85E+07 0.0541 5.66E+08 0.0037 5.39E+06 0.3863 Eu-152 0.00599 1.34E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.83E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[72]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 186 P236 Position #19 18 2.24E+06 H-3 1.76 3.65E+06 2.33E+08 0.0157 0.1179 3.42E+09 0.0011 0.0080 3.25E+07 0.1124 0.8427 Co-60 0.06431 1.44E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0067 Ni-63 442 6.35E+07 3.93E+09 0.0162 5.78E+10 0.0011 5.50E+08 0.1155 Sr-90 0.021 4.36E+04 1.40E+06 0.0311 2.06E+07 0.0021 1.96E+05 0.2224 Cs-134 0.00014 3.05E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.08E+06 3.85E+07 0.0539 5.66E+08 0.0037 5.39E+06 0.3852 Eu-152 0.00599 1.34E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.83E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 187 P236 Position #20 19 2.12E+06 H-3 1.76 3.47E+06 2.33E+08 0.0149 0.1118 3.42E+09 0.0010 0.0076 3.25E+07 0.1066 0.7993 Co-60 0.06431 1.36E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0063 Ni-63 442 6.03E+07 3.93E+09 0.0153 5.78E+10 0.0010 5.50E+08 0.1096 Sr-90 0.021 4.14E+04 1.40E+06 0.0295 2.06E+07 0.0020 1.96E+05 0.2110 Cs-134 0.00014 2.89E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.97E+06 3.85E+07 0.0511 5.66E+08 0.0035 5.39E+06 0.3654 Eu-152 0.00599 1.27E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.73E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 188 P236 Position #21 20 2.07E+06 H-3 1.76 3.38E+06 2.33E+08 0.0145 0.1092 3.42E+09 0.0010 0.0074 3.25E+07 0.1042 0.7806 Co-60 0.06431 1.33E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.89E+07 3.93E+09 0.0150 5.78E+10 0.0010 5.50E+08 0.1070 Sr-90 0.021 4.04E+04 1.40E+06 0.0288 2.06E+07 0.0020 1.96E+05 0.2061 Cs-134 0.00014 2.82E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.92E+06 3.85E+07 0.0500 5.66E+08 0.0034 5.39E+06 0.3568 Eu-152 0.00599 1.24E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.69E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 189 P236 Position #22 21 2.04E+06 H-3 1.76 3.33E+06 2.33E+08 0.0143 0.1074 3.42E+09 0.0010 0.0073 3.25E+07 0.1024 0.7678 Co-60 0.06431 1.31E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.79E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1053 Sr-90 0.021 3.97E+04 1.40E+06 0.0284 2.06E+07 0.0019 1.96E+05 0.2027 Cs-134 0.00014 2.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0491 5.66E+08 0.0033 5.39E+06 0.3510 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 190 P236 Position #23 22 1.96E+06 H-3 1.76 3.20E+06 2.33E+08 0.0137 0.1033 3.42E+09 0.0009 0.0070 3.25E+07 0.0985 0.7384 Co-60 0.06431 1.26E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.57E+07 3.93E+09 0.0142 5.78E+10 0.0010 5.50E+08 0.1012 Sr-90 0.021 3.82E+04 1.40E+06 0.0273 2.06E+07 0.0019 1.96E+05 0.1949 Cs-134 0.00014 2.67E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.82E+06 3.85E+07 0.0473 5.66E+08 0.0032 5.39E+06 0.3375 Eu-152 0.00599 1.17E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.60E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 191 P236 Position #24 23 1.91E+06 H-3 1.76 3.12E+06 2.33E+08 0.0134 0.1006 3.42E+09 0.0009 0.0068 3.25E+07 0.0960 0.7191 Co-60 0.06431 1.23E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0057 Ni-63 442 5.42E+07 3.93E+09 0.0138 5.78E+10 0.0009 5.50E+08 0.0986 Sr-90 0.021 3.72E+04 1.40E+06 0.0266 2.06E+07 0.0018 1.96E+05 0.1898 Cs-134 0.00014 2.60E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.77E+06 3.85E+07 0.0460 5.66E+08 0.0031 5.39E+06 0.3287 Eu-152 0.00599 1.14E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.56E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[73]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 192 P236 Position #25 24 1.94E+06 H-3 1.76 3.18E+06 2.33E+08 0.0136 0.1025 3.42E+09 0.0009 0.0070 3.25E+07 0.0977 0.7326 Co-60 0.06431 1.25E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0058 Ni-63 442 5.52E+07 3.93E+09 0.0141 5.78E+10 0.0010 5.50E+08 0.1004 Sr-90 0.021 3.79E+04 1.40E+06 0.0271 2.06E+07 0.0018 1.96E+05 0.1934 Cs-134 0.00014 2.65E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.80E+06 3.85E+07 0.0469 5.66E+08 0.0032 5.39E+06 0.3349 Eu-152 0.00599 1.16E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.59E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 193 P236 Position #26 25 1.95E+06 H-3 1.76 3.19E+06 2.33E+08 0.0137 0.1028 3.42E+09 0.0009 0.0070 3.25E+07 0.0981 0.7350 Co-60 0.06431 1.25E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0058 Ni-63 442 5.54E+07 3.93E+09 0.0141 5.78E+10 0.0010 5.50E+08 0.1008 Sr-90 0.021 3.80E+04 1.40E+06 0.0272 2.06E+07 0.0018 1.96E+05 0.1940 Cs-134 0.00014 2.66E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.81E+06 3.85E+07 0.0470 5.66E+08 0.0032 5.39E+06 0.3360 Eu-152 0.00599 1.17E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.59E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 194 P236 Position #27 26 2.01E+06 H-3 1.76 3.28E+06 2.33E+08 0.0141 0.1058 3.42E+09 0.0010 0.0072 3.25E+07 0.1009 0.7560 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.70E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1036 Sr-90 0.021 3.91E+04 1.40E+06 0.0279 2.06E+07 0.0019 1.96E+05 0.1996 Cs-134 0.00014 2.73E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.86E+06 3.85E+07 0.0484 5.66E+08 0.0033 5.39E+06 0.3456 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 195 P236 Position #28 27 2.04E+06 H-3 1.76 3.33E+06 2.33E+08 0.0143 0.1073 3.42E+09 0.0010 0.0073 3.25E+07 0.1024 0.7672 Co-60 0.06431 1.31E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.78E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1052 Sr-90 0.021 3.97E+04 1.40E+06 0.0284 2.06E+07 0.0019 1.96E+05 0.2025 Cs-134 0.00014 2.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0491 5.66E+08 0.0033 5.39E+06 0.3507 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 196 P236 Position #29 28 1.98E+06 H-3 1.76 3.24E+06 2.33E+08 0.0139 0.1046 3.42E+09 0.0009 0.0071 3.25E+07 0.0997 0.7476 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.64E+07 3.93E+09 0.0143 5.78E+10 0.0010 5.50E+08 0.1025 Sr-90 0.021 3.87E+04 1.40E+06 0.0276 2.06E+07 0.0019 1.96E+05 0.1974 Cs-134 0.00014 2.70E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.84E+06 3.85E+07 0.0478 5.66E+08 0.0033 5.39E+06 0.3417 Eu-152 0.00599 1.19E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.62E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 197 P236 Position #30 29 1.99E+06 H-3 1.76 3.25E+06 2.33E+08 0.0140 0.1049 3.42E+09 0.0010 0.0071 3.25E+07 0.1000 0.7496 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.65E+07 3.93E+09 0.0144 5.78E+10 0.0010 5.50E+08 0.1028 Sr-90 0.021 3.88E+04 1.40E+06 0.0277 2.06E+07 0.0019 1.96E+05 0.1979 Cs-134 0.00014 2.71E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.85E+06 3.85E+07 0.0480 5.66E+08 0.0033 5.39E+06 0.3426 Eu-152 0.00599 1.19E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.63E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[74]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 198 P236 Position #31 30 2.02E+06 H-3 1.76 3.31E+06 2.33E+08 0.0142 0.1066 3.42E+09 0.0010 0.0073 3.25E+07 0.1017 0.7622 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.75E+07 3.93E+09 0.0146 5.78E+10 0.0010 5.50E+08 0.1045 Sr-90 0.021 3.94E+04 1.40E+06 0.0282 2.06E+07 0.0019 1.96E+05 0.2012 Cs-134 0.00014 2.75E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.88E+06 3.85E+07 0.0488 5.66E+08 0.0033 5.39E+06 0.3484 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.65E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 199 P236 Position #32 31 2.02E+06 H-3 1.76 3.30E+06 2.33E+08 0.0142 0.1064 3.42E+09 0.0010 0.0072 3.25E+07 0.1014 0.7603 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.73E+07 3.93E+09 0.0146 5.78E+10 0.0010 5.50E+08 0.1042 Sr-90 0.021 3.93E+04 1.40E+06 0.0281 2.06E+07 0.0019 1.96E+05 0.2007 Cs-134 0.00014 2.75E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.87E+06 3.85E+07 0.0487 5.66E+08 0.0033 5.39E+06 0.3475 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.65E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 200 P236 Position #33 32 1.93E+06 H-3 1.76 3.15E+06 2.33E+08 0.0135 0.1017 3.42E+09 0.0009 0.0069 3.25E+07 0.0969 0.7266 Co-60 0.06431 1.24E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0058 Ni-63 442 5.48E+07 3.93E+09 0.0139 5.78E+10 0.0009 5.50E+08 0.0996 Sr-90 0.021 3.76E+04 1.40E+06 0.0269 2.06E+07 0.0018 1.96E+05 0.1918 Cs-134 0.00014 2.63E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.79E+06 3.85E+07 0.0465 5.66E+08 0.0032 5.39E+06 0.3321 Eu-152 0.00599 1.16E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.58E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 201 P236 Position #34 33 2.01E+06 H-3 1.76 3.28E+06 2.33E+08 0.0141 0.1059 3.42E+09 0.0010 0.0072 3.25E+07 0.1010 0.7571 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.71E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1038 Sr-90 0.021 3.92E+04 1.40E+06 0.0280 2.06E+07 0.0019 1.96E+05 0.1998 Cs-134 0.00014 2.74E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.87E+06 3.85E+07 0.0484 5.66E+08 0.0033 5.39E+06 0.3461 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 202 P236 Position #35 34 2.01E+06 H-3 1.76 3.29E+06 2.33E+08 0.0141 0.1061 3.42E+09 0.0010 0.0072 3.25E+07 0.1011 0.7580 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.72E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1039 Sr-90 0.021 3.92E+04 1.40E+06 0.0280 2.06E+07 0.0019 1.96E+05 0.2001 Cs-134 0.00014 2.74E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.87E+06 3.85E+07 0.0485 5.66E+08 0.0033 5.39E+06 0.3465 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 203 P236 Position #36 35 1.96E+06 H-3 1.76 3.20E+06 2.33E+08 0.0137 0.1031 3.42E+09 0.0009 0.0070 3.25E+07 0.0983 0.7371 Co-60 0.06431 1.26E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0058 Ni-63 442 5.56E+07 3.93E+09 0.0141 5.78E+10 0.0010 5.50E+08 0.1011 Sr-90 0.021 3.81E+04 1.40E+06 0.0272 2.06E+07 0.0019 1.96E+05 0.1946 Cs-134 0.00014 2.66E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.82E+06 3.85E+07 0.0472 5.66E+08 0.0032 5.39E+06 0.3369 Eu-152 0.00599 1.17E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.60E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[75]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 204 P236 Position #37 36 2.05E+06 H-3 1.76 3.35E+06 2.33E+08 0.0144 0.1082 3.42E+09 0.0010 0.0074 3.25E+07 0.1032 0.7731 Co-60 0.06431 1.32E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.83E+07 3.93E+09 0.0148 5.78E+10 0.0010 5.50E+08 0.1060 Sr-90 0.021 4.00E+04 1.40E+06 0.0286 2.06E+07 0.0019 1.96E+05 0.2041 Cs-134 0.00014 2.79E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.90E+06 3.85E+07 0.0495 5.66E+08 0.0034 5.39E+06 0.3534 Eu-152 0.00599 1.23E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.68E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 205 P236 Position #38 37 1.98E+06 H-3 1.76 3.24E+06 2.33E+08 0.0139 0.1047 3.42E+09 0.0009 0.0071 3.25E+07 0.0998 0.7482 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.64E+07 3.93E+09 0.0144 5.78E+10 0.0010 5.50E+08 0.1026 Sr-90 0.021 3.87E+04 1.40E+06 0.0277 2.06E+07 0.0019 1.96E+05 0.1975 Cs-134 0.00014 2.70E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.84E+06 3.85E+07 0.0479 5.66E+08 0.0033 5.39E+06 0.3420 Eu-152 0.00599 1.19E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.62E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 206 P236 Position #39 38 2.05E+06 H-3 1.76 3.35E+06 2.33E+08 0.0144 0.1080 3.42E+09 0.0010 0.0073 3.25E+07 0.1030 0.7719 Co-60 0.06431 1.32E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.82E+07 3.93E+09 0.0148 5.78E+10 0.0010 5.50E+08 0.1058 Sr-90 0.021 3.99E+04 1.40E+06 0.0285 2.06E+07 0.0019 1.96E+05 0.2038 Cs-134 0.00014 2.79E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.90E+06 3.85E+07 0.0494 5.66E+08 0.0034 5.39E+06 0.3528 Eu-152 0.00599 1.23E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.67E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 207 P236 Position #40 39 2.08E+06 H-3 1.76 3.40E+06 2.33E+08 0.0146 0.1098 3.42E+09 0.0010 0.0075 3.25E+07 0.1047 0.7848 Co-60 0.06431 1.34E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.92E+07 3.93E+09 0.0151 5.78E+10 0.0010 5.50E+08 0.1076 Sr-90 0.021 4.06E+04 1.40E+06 0.0290 2.06E+07 0.0020 1.96E+05 0.2072 Cs-134 0.00014 2.84E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.93E+06 3.85E+07 0.0502 5.66E+08 0.0034 5.39E+06 0.3587 Eu-152 0.00599 1.25E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.70E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 208 P236 Position #41 40 2.06E+06 H-3 1.76 3.36E+06 2.33E+08 0.0144 0.1085 3.42E+09 0.0010 0.0074 3.25E+07 0.1034 0.7751 Co-60 0.06431 1.32E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.84E+07 3.93E+09 0.0149 5.78E+10 0.0010 5.50E+08 0.1063 Sr-90 0.021 4.01E+04 1.40E+06 0.0286 2.06E+07 0.0019 1.96E+05 0.2046 Cs-134 0.00014 2.80E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.91E+06 3.85E+07 0.0496 5.66E+08 0.0034 5.39E+06 0.3543 Eu-152 0.00599 1.23E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.68E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 209 P236 Position #42 41 2.01E+06 H-3 1.76 3.29E+06 2.33E+08 0.0141 0.1063 3.42E+09 0.0010 0.0072 3.25E+07 0.1013 0.7594 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.73E+07 3.93E+09 0.0146 5.78E+10 0.0010 5.50E+08 0.1041 Sr-90 0.021 3.93E+04 1.40E+06 0.0281 2.06E+07 0.0019 1.96E+05 0.2005 Cs-134 0.00014 2.74E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.87E+06 3.85E+07 0.0486 5.66E+08 0.0033 5.39E+06 0.3471 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.65E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[76]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 210 P236 Position #43 42 2.05E+06 H-3 1.76 3.34E+06 2.33E+08 0.0144 0.1079 3.42E+09 0.0010 0.0073 3.25E+07 0.1029 0.7712 Co-60 0.06431 1.32E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.81E+07 3.93E+09 0.0148 5.78E+10 0.0010 5.50E+08 0.1057 Sr-90 0.021 3.99E+04 1.40E+06 0.0285 2.06E+07 0.0019 1.96E+05 0.2036 Cs-134 0.00014 2.79E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.90E+06 3.85E+07 0.0494 5.66E+08 0.0034 5.39E+06 0.3525 Eu-152 0.00599 1.23E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.67E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 211 P236 Position #44 43 2.04E+06 H-3 1.76 3.33E+06 2.33E+08 0.0143 0.1076 3.42E+09 0.0010 0.0073 3.25E+07 0.1026 0.7691 Co-60 0.06431 1.31E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.80E+07 3.93E+09 0.0148 5.78E+10 0.0010 5.50E+08 0.1054 Sr-90 0.021 3.98E+04 1.40E+06 0.0284 2.06E+07 0.0019 1.96E+05 0.2030 Cs-134 0.00014 2.78E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0492 5.66E+08 0.0033 5.39E+06 0.3515 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.67E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 212 P236 Position #45 44 2.02E+06 H-3 1.76 3.30E+06 2.33E+08 0.0142 0.1065 3.42E+09 0.0010 0.0072 3.25E+07 0.1016 0.7611 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.74E+07 3.93E+09 0.0146 5.78E+10 0.0010 5.50E+08 0.1043 Sr-90 0.021 3.94E+04 1.40E+06 0.0281 2.06E+07 0.0019 1.96E+05 0.2009 Cs-134 0.00014 2.75E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.88E+06 3.85E+07 0.0487 5.66E+08 0.0033 5.39E+06 0.3479 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.65E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 213 P236 Position #46 45 2.08E+06 H-3 1.76 3.39E+06 2.33E+08 0.0146 0.1095 3.42E+09 0.0010 0.0074 3.25E+07 0.1044 0.7826 Co-60 0.06431 1.34E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.90E+07 3.93E+09 0.0150 5.78E+10 0.0010 5.50E+08 0.1073 Sr-90 0.021 4.05E+04 1.40E+06 0.0289 2.06E+07 0.0020 1.96E+05 0.2066 Cs-134 0.00014 2.83E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.93E+06 3.85E+07 0.0501 5.66E+08 0.0034 5.39E+06 0.3577 Eu-152 0.00599 1.24E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.70E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 214 P236 Position #47 46 2.09E+06 H-3 1.76 3.41E+06 2.33E+08 0.0147 0.1102 3.42E+09 0.0010 0.0075 3.25E+07 0.1051 0.7875 Co-60 0.06431 1.34E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.94E+07 3.93E+09 0.0151 5.78E+10 0.0010 5.50E+08 0.1080 Sr-90 0.021 4.07E+04 1.40E+06 0.0291 2.06E+07 0.0020 1.96E+05 0.2079 Cs-134 0.00014 2.85E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.94E+06 3.85E+07 0.0504 5.66E+08 0.0034 5.39E+06 0.3600 Eu-152 0.00599 1.25E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.71E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 215 P236 Position #48 47 2.10E+06 H-3 1.76 3.42E+06 2.33E+08 0.0147 0.1105 3.42E+09 0.0010 0.0075 3.25E+07 0.1054 0.7898 Co-60 0.06431 1.35E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0063 Ni-63 442 5.96E+07 3.93E+09 0.0152 5.78E+10 0.0010 5.50E+08 0.1083 Sr-90 0.021 4.09E+04 1.40E+06 0.0292 2.06E+07 0.0020 1.96E+05 0.2085 Cs-134 0.00014 2.85E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.95E+06 3.85E+07 0.0505 5.66E+08 0.0034 5.39E+06 0.3610 Eu-152 0.00599 1.26E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.71E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[77]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 216 P236 Position #49 48 2.04E+06 H-3 1.76 3.33E+06 2.33E+08 0.0143 0.1076 3.42E+09 0.0010 0.0073 3.25E+07 0.1026 0.7688 Co-60 0.06431 1.31E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.80E+07 3.93E+09 0.0148 5.78E+10 0.0010 5.50E+08 0.1054 Sr-90 0.021 3.98E+04 1.40E+06 0.0284 2.06E+07 0.0019 1.96E+05 0.2030 Cs-134 0.00014 2.78E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0492 5.66E+08 0.0033 5.39E+06 0.3514 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.67E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 217 P236 Position #50 49 2.13E+06 H-3 1.76 3.48E+06 2.33E+08 0.0149 0.1123 3.42E+09 0.0010 0.0076 3.25E+07 0.1071 0.8029 Co-60 0.06431 1.37E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0064 Ni-63 442 6.05E+07 3.93E+09 0.0154 5.78E+10 0.0010 5.50E+08 0.1101 Sr-90 0.021 4.15E+04 1.40E+06 0.0297 2.06E+07 0.0020 1.96E+05 0.2119 Cs-134 0.00014 2.90E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.98E+06 3.85E+07 0.0514 5.66E+08 0.0035 5.39E+06 0.3670 Eu-152 0.00599 1.28E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.74E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 218 P235 Position #1 0

5.66E+06 H-3 1.76 9.25E+06 2.33E+08 0.0397 0.2984 3.42E+09 0.0027 0.0203 3.25E+07 0.2846 2.1327 Co-60 0.06431 3.64E+05 1.54E+08 0.0024 2.26E+09 0.0002 2.15E+07 0.0169 Ni-63 442 1.61E+08 3.93E+09 0.0409 5.78E+10 0.0028 5.50E+08 0.2924 Sr-90 0.021 1.10E+05 1.40E+06 0.0788 2.06E+07 0.0054 1.96E+05 0.5630 Cs-134 0.00014 7.71E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 5.25E+06 3.85E+07 0.1365 5.66E+08 0.0093 5.39E+06 0.9749 Eu-152 0.00599 3.39E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0007 Eu-154 0.00082 4.62E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 219 P235 Position #2 1

3.02E+06 H-3 1.76 4.94E+06 2.33E+08 0.0212 0.1595 3.42E+09 0.0014 0.0108 3.25E+07 0.1521 1.1397 Co-60 0.06431 1.94E+05 1.54E+08 0.0013 2.26E+09 0.0001 2.15E+07 0.0090 Ni-63 442 8.59E+07 3.93E+09 0.0219 5.78E+10 0.0015 5.50E+08 0.1562 Sr-90 0.021 5.90E+04 1.40E+06 0.0421 2.06E+07 0.0029 1.96E+05 0.3009 Cs-134 0.00014 4.12E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.81E+06 3.85E+07 0.0729 5.66E+08 0.0050 5.39E+06 0.5210 Eu-152 0.00599 1.81E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.47E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 220 P235 Position #3 2

2.42E+06 H-3 1.76 3.96E+06 2.33E+08 0.0170 0.1278 3.42E+09 0.0012 0.0087 3.25E+07 0.1219 0.9137 Co-60 0.06431 1.56E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0072 Ni-63 442 6.89E+07 3.93E+09 0.0175 5.78E+10 0.0012 5.50E+08 0.1253 Sr-90 0.021 4.73E+04 1.40E+06 0.0338 2.06E+07 0.0023 1.96E+05 0.2412 Cs-134 0.00014 3.30E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.25E+06 3.85E+07 0.0585 5.66E+08 0.0040 5.39E+06 0.4177 Eu-152 0.00599 1.45E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.98E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 221 P235 Position #4 3

2.45E+06 H-3 1.76 4.01E+06 2.33E+08 0.0172 0.1293 3.42E+09 0.0012 0.0088 3.25E+07 0.1233 0.9241 Co-60 0.06431 1.58E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.97E+07 3.93E+09 0.0177 5.78E+10 0.0012 5.50E+08 0.1267 Sr-90 0.021 4.78E+04 1.40E+06 0.0342 2.06E+07 0.0023 1.96E+05 0.2439 Cs-134 0.00014 3.34E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.28E+06 3.85E+07 0.0591 5.66E+08 0.0040 5.39E+06 0.4224 Eu-152 0.00599 1.47E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.00E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[78]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 222 P235 Position #5 4

2.42E+06 H-3 1.76 3.96E+06 2.33E+08 0.0170 0.1279 3.42E+09 0.0012 0.0087 3.25E+07 0.1219 0.9138 Co-60 0.06431 1.56E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.89E+07 3.93E+09 0.0175 5.78E+10 0.0012 5.50E+08 0.1253 Sr-90 0.021 4.73E+04 1.40E+06 0.0338 2.06E+07 0.0023 1.96E+05 0.2412 Cs-134 0.00014 3.30E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.25E+06 3.85E+07 0.0585 5.66E+08 0.0040 5.39E+06 0.4177 Eu-152 0.00599 1.45E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.98E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 223 P235 Position #6 5

2.44E+06 H-3 1.76 3.99E+06 2.33E+08 0.0171 0.1287 3.42E+09 0.0012 0.0088 3.25E+07 0.1227 0.9198 Co-60 0.06431 1.57E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.94E+07 3.93E+09 0.0176 5.78E+10 0.0012 5.50E+08 0.1261 Sr-90 0.021 4.76E+04 1.40E+06 0.0340 2.06E+07 0.0023 1.96E+05 0.2428 Cs-134 0.00014 3.32E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.27E+06 3.85E+07 0.0589 5.66E+08 0.0040 5.39E+06 0.4204 Eu-152 0.00599 1.46E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.99E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 224 P235 Position #7 6

2.39E+06 H-3 1.76 3.91E+06 2.33E+08 0.0168 0.1262 3.42E+09 0.0011 0.0086 3.25E+07 0.1203 0.9018 Co-60 0.06431 1.54E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0072 Ni-63 442 6.80E+07 3.93E+09 0.0173 5.78E+10 0.0012 5.50E+08 0.1236 Sr-90 0.021 4.67E+04 1.40E+06 0.0333 2.06E+07 0.0023 1.96E+05 0.2381 Cs-134 0.00014 3.26E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.22E+06 3.85E+07 0.0577 5.66E+08 0.0039 5.39E+06 0.4122 Eu-152 0.00599 1.43E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.96E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 225 P235 Position #8 7

2.42E+06 H-3 1.76 3.95E+06 2.33E+08 0.0169 0.1274 3.42E+09 0.0012 0.0087 3.25E+07 0.1215 0.9105 Co-60 0.06431 1.55E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0072 Ni-63 442 6.87E+07 3.93E+09 0.0175 5.78E+10 0.0012 5.50E+08 0.1248 Sr-90 0.021 4.71E+04 1.40E+06 0.0337 2.06E+07 0.0023 1.96E+05 0.2404 Cs-134 0.00014 3.29E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.24E+06 3.85E+07 0.0583 5.66E+08 0.0040 5.39E+06 0.4162 Eu-152 0.00599 1.45E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.97E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 226 P235 Position #9 8

2.45E+06 H-3 1.76 4.01E+06 2.33E+08 0.0172 0.1294 3.42E+09 0.0012 0.0088 3.25E+07 0.1234 0.9245 Co-60 0.06431 1.58E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.97E+07 3.93E+09 0.0177 5.78E+10 0.0012 5.50E+08 0.1267 Sr-90 0.021 4.78E+04 1.40E+06 0.0342 2.06E+07 0.0023 1.96E+05 0.2441 Cs-134 0.00014 3.34E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.28E+06 3.85E+07 0.0592 5.66E+08 0.0040 5.39E+06 0.4226 Eu-152 0.00599 1.47E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.00E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 227 P235 Position #10 9

2.45E+06 H-3 1.76 4.00E+06 2.33E+08 0.0172 0.1290 3.42E+09 0.0012 0.0088 3.25E+07 0.1230 0.9217 Co-60 0.06431 1.57E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.95E+07 3.93E+09 0.0177 5.78E+10 0.0012 5.50E+08 0.1264 Sr-90 0.021 4.77E+04 1.40E+06 0.0341 2.06E+07 0.0023 1.96E+05 0.2433 Cs-134 0.00014 3.33E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.27E+06 3.85E+07 0.0590 5.66E+08 0.0040 5.39E+06 0.4213 Eu-152 0.00599 1.47E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.00E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[79]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 228 P235 Position #11 10 2.38E+06 H-3 1.76 3.88E+06 2.33E+08 0.0167 0.1253 3.42E+09 0.0011 0.0085 3.25E+07 0.1195 0.8957 Co-60 0.06431 1.53E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0071 Ni-63 442 6.75E+07 3.93E+09 0.0172 5.78E+10 0.0012 5.50E+08 0.1228 Sr-90 0.021 4.63E+04 1.40E+06 0.0331 2.06E+07 0.0022 1.96E+05 0.2365 Cs-134 0.00014 3.24E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.21E+06 3.85E+07 0.0573 5.66E+08 0.0039 5.39E+06 0.4094 Eu-152 0.00599 1.42E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.94E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 229 P235 Position #12 11 2.38E+06 H-3 1.76 3.89E+06 2.33E+08 0.0167 0.1256 3.42E+09 0.0011 0.0085 3.25E+07 0.1198 0.8978 Co-60 0.06431 1.53E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0071 Ni-63 442 6.77E+07 3.93E+09 0.0172 5.78E+10 0.0012 5.50E+08 0.1231 Sr-90 0.021 4.65E+04 1.40E+06 0.0332 2.06E+07 0.0023 1.96E+05 0.2370 Cs-134 0.00014 3.24E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.21E+06 3.85E+07 0.0575 5.66E+08 0.0039 5.39E+06 0.4104 Eu-152 0.00599 1.43E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.95E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 230 P235 Position #13 12 2.37E+06 H-3 1.76 3.87E+06 2.33E+08 0.0166 0.1249 3.42E+09 0.0011 0.0085 3.25E+07 0.1191 0.8923 Co-60 0.06431 1.52E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0071 Ni-63 442 6.73E+07 3.93E+09 0.0171 5.78E+10 0.0012 5.50E+08 0.1223 Sr-90 0.021 4.62E+04 1.40E+06 0.0330 2.06E+07 0.0022 1.96E+05 0.2356 Cs-134 0.00014 3.23E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.20E+06 3.85E+07 0.0571 5.66E+08 0.0039 5.39E+06 0.4079 Eu-152 0.00599 1.42E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.94E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 231 P235 Position #14 13 2.37E+06 H-3 1.76 3.87E+06 2.33E+08 0.0166 0.1248 3.42E+09 0.0011 0.0085 3.25E+07 0.1190 0.8920 Co-60 0.06431 1.52E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0071 Ni-63 442 6.73E+07 3.93E+09 0.0171 5.78E+10 0.0012 5.50E+08 0.1223 Sr-90 0.021 4.62E+04 1.40E+06 0.0330 2.06E+07 0.0022 1.96E+05 0.2355 Cs-134 0.00014 3.22E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.20E+06 3.85E+07 0.0571 5.66E+08 0.0039 5.39E+06 0.4077 Eu-152 0.00599 1.42E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.93E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 232 P235 Position #15 14 2.35E+06 H-3 1.76 3.85E+06 2.33E+08 0.0165 0.1241 3.42E+09 0.0011 0.0084 3.25E+07 0.1183 0.8867 Co-60 0.06431 1.51E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0070 Ni-63 442 6.69E+07 3.93E+09 0.0170 5.78E+10 0.0012 5.50E+08 0.1216 Sr-90 0.021 4.59E+04 1.40E+06 0.0328 2.06E+07 0.0022 1.96E+05 0.2341 Cs-134 0.00014 3.20E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.18E+06 3.85E+07 0.0567 5.66E+08 0.0039 5.39E+06 0.4053 Eu-152 0.00599 1.41E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.92E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 233 P235 Position #16 15 2.31E+06 H-3 1.76 3.78E+06 2.33E+08 0.0162 0.1220 3.42E+09 0.0011 0.0083 3.25E+07 0.1163 0.8716 Co-60 0.06431 1.49E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0069 Ni-63 442 6.57E+07 3.93E+09 0.0167 5.78E+10 0.0011 5.50E+08 0.1195 Sr-90 0.021 4.51E+04 1.40E+06 0.0322 2.06E+07 0.0022 1.96E+05 0.2301 Cs-134 0.00014 3.15E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.15E+06 3.85E+07 0.0558 5.66E+08 0.0038 5.39E+06 0.3984 Eu-152 0.00599 1.39E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.89E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[80]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 234 P235 Position #17 16 2.34E+06 H-3 1.76 3.82E+06 2.33E+08 0.0164 0.1232 3.42E+09 0.0011 0.0084 3.25E+07 0.1175 0.8804 Co-60 0.06431 1.50E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0070 Ni-63 442 6.64E+07 3.93E+09 0.0169 5.78E+10 0.0011 5.50E+08 0.1207 Sr-90 0.021 4.56E+04 1.40E+06 0.0325 2.06E+07 0.0022 1.96E+05 0.2324 Cs-134 0.00014 3.18E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.17E+06 3.85E+07 0.0563 5.66E+08 0.0038 5.39E+06 0.4025 Eu-152 0.00599 1.40E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.91E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 235 P235 Position #18 17 2.31E+06 H-3 1.76 3.77E+06 2.33E+08 0.0162 0.1218 3.42E+09 0.0011 0.0083 3.25E+07 0.1161 0.8704 Co-60 0.06431 1.48E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0069 Ni-63 442 6.56E+07 3.93E+09 0.0167 5.78E+10 0.0011 5.50E+08 0.1193 Sr-90 0.021 4.50E+04 1.40E+06 0.0322 2.06E+07 0.0022 1.96E+05 0.2298 Cs-134 0.00014 3.15E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.14E+06 3.85E+07 0.0557 5.66E+08 0.0038 5.39E+06 0.3979 Eu-152 0.00599 1.38E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.89E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 236 P235 Position #19 18 2.26E+06 H-3 1.76 3.70E+06 2.33E+08 0.0159 0.1193 3.42E+09 0.0011 0.0081 3.25E+07 0.1138 0.8526 Co-60 0.06431 1.45E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0068 Ni-63 442 6.43E+07 3.93E+09 0.0164 5.78E+10 0.0011 5.50E+08 0.1169 Sr-90 0.021 4.41E+04 1.40E+06 0.0315 2.06E+07 0.0021 1.96E+05 0.2251 Cs-134 0.00014 3.08E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.10E+06 3.85E+07 0.0546 5.66E+08 0.0037 5.39E+06 0.3897 Eu-152 0.00599 1.36E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.85E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 237 P235 Position #20 19 2.16E+06 H-3 1.76 3.53E+06 2.33E+08 0.0151 0.1138 3.42E+09 0.0010 0.0077 3.25E+07 0.1086 0.8136 Co-60 0.06431 1.39E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0065 Ni-63 442 6.13E+07 3.93E+09 0.0156 5.78E+10 0.0011 5.50E+08 0.1115 Sr-90 0.021 4.21E+04 1.40E+06 0.0301 2.06E+07 0.0020 1.96E+05 0.2148 Cs-134 0.00014 2.94E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.00E+06 3.85E+07 0.0521 5.66E+08 0.0035 5.39E+06 0.3719 Eu-152 0.00599 1.29E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.76E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 238 P235 Position #21 20 2.11E+06 H-3 1.76 3.45E+06 2.33E+08 0.0148 0.1112 3.42E+09 0.0010 0.0076 3.25E+07 0.1061 0.7948 Co-60 0.06431 1.36E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0063 Ni-63 442 5.99E+07 3.93E+09 0.0152 5.78E+10 0.0010 5.50E+08 0.1090 Sr-90 0.021 4.11E+04 1.40E+06 0.0294 2.06E+07 0.0020 1.96E+05 0.2098 Cs-134 0.00014 2.87E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.96E+06 3.85E+07 0.0509 5.66E+08 0.0035 5.39E+06 0.3633 Eu-152 0.00599 1.26E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.72E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 239 P235 Position #22 21 2.06E+06 H-3 1.76 3.37E+06 2.33E+08 0.0145 0.1088 3.42E+09 0.0010 0.0074 3.25E+07 0.1038 0.7778 Co-60 0.06431 1.33E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.86E+07 3.93E+09 0.0149 5.78E+10 0.0010 5.50E+08 0.1066 Sr-90 0.021 4.02E+04 1.40E+06 0.0287 2.06E+07 0.0020 1.96E+05 0.2053 Cs-134 0.00014 2.81E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.92E+06 3.85E+07 0.0498 5.66E+08 0.0034 5.39E+06 0.3555 Eu-152 0.00599 1.24E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.69E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[81]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 240 P235 Position #23 22 2.03E+06 H-3 1.76 3.32E+06 2.33E+08 0.0142 0.1071 3.42E+09 0.0010 0.0073 3.25E+07 0.1021 0.7653 Co-60 0.06431 1.31E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.77E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1049 Sr-90 0.021 3.96E+04 1.40E+06 0.0283 2.06E+07 0.0019 1.96E+05 0.2020 Cs-134 0.00014 2.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0490 5.66E+08 0.0033 5.39E+06 0.3498 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 241 P235 Position #24 23 1.98E+06 H-3 1.76 3.23E+06 2.33E+08 0.0139 0.1042 3.42E+09 0.0009 0.0071 3.25E+07 0.0994 0.7447 Co-60 0.06431 1.27E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0059 Ni-63 442 5.62E+07 3.93E+09 0.0143 5.78E+10 0.0010 5.50E+08 0.1021 Sr-90 0.021 3.85E+04 1.40E+06 0.0275 2.06E+07 0.0019 1.96E+05 0.1966 Cs-134 0.00014 2.69E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.83E+06 3.85E+07 0.0477 5.66E+08 0.0032 5.39E+06 0.3404 Eu-152 0.00599 1.18E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.61E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 242 P235 Position #25 24 2.00E+06 H-3 1.76 3.26E+06 2.33E+08 0.0140 0.1053 3.42E+09 0.0010 0.0072 3.25E+07 0.1004 0.7524 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.67E+07 3.93E+09 0.0144 5.78E+10 0.0010 5.50E+08 0.1031 Sr-90 0.021 3.89E+04 1.40E+06 0.0278 2.06E+07 0.0019 1.96E+05 0.1986 Cs-134 0.00014 2.72E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.85E+06 3.85E+07 0.0481 5.66E+08 0.0033 5.39E+06 0.3439 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.63E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 243 P235 Position #26 25 2.00E+06 H-3 1.76 3.26E+06 2.33E+08 0.0140 0.1053 3.42E+09 0.0010 0.0072 3.25E+07 0.1004 0.7525 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.67E+07 3.93E+09 0.0144 5.78E+10 0.0010 5.50E+08 0.1032 Sr-90 0.021 3.89E+04 1.40E+06 0.0278 2.06E+07 0.0019 1.96E+05 0.1986 Cs-134 0.00014 2.72E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.85E+06 3.85E+07 0.0482 5.66E+08 0.0033 5.39E+06 0.3440 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.63E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 244 P235 Position #27 26 2.07E+06 H-3 1.76 3.39E+06 2.33E+08 0.0145 0.1093 3.42E+09 0.0010 0.0074 3.25E+07 0.1042 0.7811 Co-60 0.06431 1.33E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.89E+07 3.93E+09 0.0150 5.78E+10 0.0010 5.50E+08 0.1071 Sr-90 0.021 4.04E+04 1.40E+06 0.0289 2.06E+07 0.0020 1.96E+05 0.2062 Cs-134 0.00014 2.82E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.92E+06 3.85E+07 0.0500 5.66E+08 0.0034 5.39E+06 0.3570 Eu-152 0.00599 1.24E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.69E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 245 P235 Position #28 27 2.02E+06 H-3 1.76 3.30E+06 2.33E+08 0.0142 0.1065 3.42E+09 0.0010 0.0072 3.25E+07 0.1015 0.7609 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.74E+07 3.93E+09 0.0146 5.78E+10 0.0010 5.50E+08 0.1043 Sr-90 0.021 3.94E+04 1.40E+06 0.0281 2.06E+07 0.0019 1.96E+05 0.2009 Cs-134 0.00014 2.75E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.87E+06 3.85E+07 0.0487 5.66E+08 0.0033 5.39E+06 0.3478 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.65E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[82]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 246 P235 Position #29 28 2.07E+06 H-3 1.76 3.38E+06 2.33E+08 0.0145 0.1092 3.42E+09 0.0010 0.0074 3.25E+07 0.1041 0.7804 Co-60 0.06431 1.33E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.88E+07 3.93E+09 0.0150 5.78E+10 0.0010 5.50E+08 0.1070 Sr-90 0.021 4.04E+04 1.40E+06 0.0288 2.06E+07 0.0020 1.96E+05 0.2060 Cs-134 0.00014 2.82E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.92E+06 3.85E+07 0.0499 5.66E+08 0.0034 5.39E+06 0.3567 Eu-152 0.00599 1.24E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.69E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 247 P235 Position #30 29 2.03E+06 H-3 1.76 3.33E+06 2.33E+08 0.0143 0.1073 3.42E+09 0.0010 0.0073 3.25E+07 0.1023 0.7671 Co-60 0.06431 1.31E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.78E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1052 Sr-90 0.021 3.97E+04 1.40E+06 0.0283 2.06E+07 0.0019 1.96E+05 0.2025 Cs-134 0.00014 2.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0491 5.66E+08 0.0033 5.39E+06 0.3506 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 248 P235 Position #31 30 2.02E+06 H-3 1.76 3.31E+06 2.33E+08 0.0142 0.1066 3.42E+09 0.0010 0.0073 3.25E+07 0.1017 0.7622 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.75E+07 3.93E+09 0.0146 5.78E+10 0.0010 5.50E+08 0.1045 Sr-90 0.021 3.94E+04 1.40E+06 0.0282 2.06E+07 0.0019 1.96E+05 0.2012 Cs-134 0.00014 2.75E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.88E+06 3.85E+07 0.0488 5.66E+08 0.0033 5.39E+06 0.3484 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.65E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 249 P235 Position #32 31 2.03E+06 H-3 1.76 3.31E+06 2.33E+08 0.0142 0.1069 3.42E+09 0.0010 0.0073 3.25E+07 0.1020 0.7643 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.76E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1048 Sr-90 0.021 3.95E+04 1.40E+06 0.0282 2.06E+07 0.0019 1.96E+05 0.2018 Cs-134 0.00014 2.76E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.88E+06 3.85E+07 0.0489 5.66E+08 0.0033 5.39E+06 0.3494 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 250 P235 Position #33 32 1.99E+06 H-3 1.76 3.25E+06 2.33E+08 0.0140 0.1049 3.42E+09 0.0010 0.0071 3.25E+07 0.1001 0.7501 Co-60 0.06431 1.28E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.66E+07 3.93E+09 0.0144 5.78E+10 0.0010 5.50E+08 0.1028 Sr-90 0.021 3.88E+04 1.40E+06 0.0277 2.06E+07 0.0019 1.96E+05 0.1980 Cs-134 0.00014 2.71E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.85E+06 3.85E+07 0.0480 5.66E+08 0.0033 5.39E+06 0.3429 Eu-152 0.00599 1.19E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.63E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 251 P235 Position #34 33 2.00E+06 H-3 1.76 3.27E+06 2.33E+08 0.0140 0.1055 3.42E+09 0.0010 0.0072 3.25E+07 0.1006 0.7539 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.68E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1034 Sr-90 0.021 3.90E+04 1.40E+06 0.0279 2.06E+07 0.0019 1.96E+05 0.1990 Cs-134 0.00014 2.72E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.86E+06 3.85E+07 0.0482 5.66E+08 0.0033 5.39E+06 0.3446 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.63E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[83]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 252 P235 Position #35 34 2.00E+06 H-3 1.76 3.27E+06 2.33E+08 0.0141 0.1056 3.42E+09 0.0010 0.0072 3.25E+07 0.1007 0.7550 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.69E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1035 Sr-90 0.021 3.91E+04 1.40E+06 0.0279 2.06E+07 0.0019 1.96E+05 0.1993 Cs-134 0.00014 2.73E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.86E+06 3.85E+07 0.0483 5.66E+08 0.0033 5.39E+06 0.3451 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 253 P235 Position #36 35 2.03E+06 H-3 1.76 3.31E+06 2.33E+08 0.0142 0.1069 3.42E+09 0.0010 0.0073 3.25E+07 0.1019 0.7638 Co-60 0.06431 1.30E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.76E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1047 Sr-90 0.021 3.95E+04 1.40E+06 0.0282 2.06E+07 0.0019 1.96E+05 0.2016 Cs-134 0.00014 2.76E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.88E+06 3.85E+07 0.0489 5.66E+08 0.0033 5.39E+06 0.3491 Eu-152 0.00599 1.21E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 254 P235 Position #37 36 2.01E+06 H-3 1.76 3.28E+06 2.33E+08 0.0141 0.1058 3.42E+09 0.0010 0.0072 3.25E+07 0.1009 0.7559 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.70E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1036 Sr-90 0.021 3.91E+04 1.40E+06 0.0279 2.06E+07 0.0019 1.96E+05 0.1995 Cs-134 0.00014 2.73E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.86E+06 3.85E+07 0.0484 5.66E+08 0.0033 5.39E+06 0.3455 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 255 P235 Position #38 37 2.07E+06 H-3 1.76 3.38E+06 2.33E+08 0.0145 0.1090 3.42E+09 0.0010 0.0074 3.25E+07 0.1040 0.7791 Co-60 0.06431 1.33E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.87E+07 3.93E+09 0.0149 5.78E+10 0.0010 5.50E+08 0.1068 Sr-90 0.021 4.03E+04 1.40E+06 0.0288 2.06E+07 0.0020 1.96E+05 0.2057 Cs-134 0.00014 2.82E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.92E+06 3.85E+07 0.0499 5.66E+08 0.0034 5.39E+06 0.3561 Eu-152 0.00599 1.24E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.69E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 256 P235 Position #39 38 2.04E+06 H-3 1.76 3.33E+06 2.33E+08 0.0143 0.1075 3.42E+09 0.0010 0.0073 3.25E+07 0.1025 0.7684 Co-60 0.06431 1.31E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.79E+07 3.93E+09 0.0147 5.78E+10 0.0010 5.50E+08 0.1053 Sr-90 0.021 3.98E+04 1.40E+06 0.0284 2.06E+07 0.0019 1.96E+05 0.2028 Cs-134 0.00014 2.78E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.89E+06 3.85E+07 0.0492 5.66E+08 0.0033 5.39E+06 0.3512 Eu-152 0.00599 1.22E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.67E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 257 P235 Position #40 39 2.01E+06 H-3 1.76 3.28E+06 2.33E+08 0.0141 0.1058 3.42E+09 0.0010 0.0072 3.25E+07 0.1009 0.7560 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.70E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1036 Sr-90 0.021 3.91E+04 1.40E+06 0.0279 2.06E+07 0.0019 1.96E+05 0.1996 Cs-134 0.00014 2.73E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.86E+06 3.85E+07 0.0484 5.66E+08 0.0033 5.39E+06 0.3456 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[84]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 258 P235 Position #41 40 2.01E+06 H-3 1.76 3.28E+06 2.33E+08 0.0141 0.1059 3.42E+09 0.0010 0.0072 3.25E+07 0.1010 0.7572 Co-60 0.06431 1.29E+05 1.54E+08 0.0008 2.26E+09 0.0001 2.15E+07 0.0060 Ni-63 442 5.71E+07 3.93E+09 0.0145 5.78E+10 0.0010 5.50E+08 0.1038 Sr-90 0.021 3.92E+04 1.40E+06 0.0280 2.06E+07 0.0019 1.96E+05 0.1999 Cs-134 0.00014 2.74E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.87E+06 3.85E+07 0.0485 5.66E+08 0.0033 5.39E+06 0.3461 Eu-152 0.00599 1.20E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.64E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 259 P235 Position #42 41 2.06E+06 H-3 1.76 3.36E+06 2.33E+08 0.0144 0.1084 3.42E+09 0.0010 0.0074 3.25E+07 0.1034 0.7750 Co-60 0.06431 1.32E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0061 Ni-63 442 5.84E+07 3.93E+09 0.0149 5.78E+10 0.0010 5.50E+08 0.1062 Sr-90 0.021 4.01E+04 1.40E+06 0.0286 2.06E+07 0.0019 1.96E+05 0.2046 Cs-134 0.00014 2.80E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.91E+06 3.85E+07 0.0496 5.66E+08 0.0034 5.39E+06 0.3543 Eu-152 0.00599 1.23E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.68E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 260 P235 Position #43 42 2.07E+06 H-3 1.76 3.38E+06 2.33E+08 0.0145 0.1090 3.42E+09 0.0010 0.0074 3.25E+07 0.1040 0.7791 Co-60 0.06431 1.33E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.87E+07 3.93E+09 0.0149 5.78E+10 0.0010 5.50E+08 0.1068 Sr-90 0.021 4.03E+04 1.40E+06 0.0288 2.06E+07 0.0020 1.96E+05 0.2057 Cs-134 0.00014 2.82E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.92E+06 3.85E+07 0.0499 5.66E+08 0.0034 5.39E+06 0.3561 Eu-152 0.00599 1.24E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.69E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 261 P235 Position #44 43 2.06E+06 H-3 1.76 3.36E+06 2.33E+08 0.0144 0.1085 3.42E+09 0.0010 0.0074 3.25E+07 0.1034 0.7751 Co-60 0.06431 1.32E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.84E+07 3.93E+09 0.0149 5.78E+10 0.0010 5.50E+08 0.1063 Sr-90 0.021 4.01E+04 1.40E+06 0.0286 2.06E+07 0.0019 1.96E+05 0.2046 Cs-134 0.00014 2.80E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.91E+06 3.85E+07 0.0496 5.66E+08 0.0034 5.39E+06 0.3543 Eu-152 0.00599 1.23E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.68E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 262 P235 Position #45 44 2.07E+06 H-3 1.76 3.38E+06 2.33E+08 0.0145 0.1090 3.42E+09 0.0010 0.0074 3.25E+07 0.1040 0.7793 Co-60 0.06431 1.33E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0062 Ni-63 442 5.88E+07 3.93E+09 0.0150 5.78E+10 0.0010 5.50E+08 0.1068 Sr-90 0.021 4.03E+04 1.40E+06 0.0288 2.06E+07 0.0020 1.96E+05 0.2057 Cs-134 0.00014 2.82E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.92E+06 3.85E+07 0.0499 5.66E+08 0.0034 5.39E+06 0.3562 Eu-152 0.00599 1.24E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0002 Eu-154 0.00082 1.69E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 263 P235 Position #46 45 2.15E+06 H-3 1.76 3.52E+06 2.33E+08 0.0151 0.1136 3.42E+09 0.0010 0.0077 3.25E+07 0.1083 0.8119 Co-60 0.06431 1.38E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0064 Ni-63 442 6.12E+07 3.93E+09 0.0156 5.78E+10 0.0011 5.50E+08 0.1113 Sr-90 0.021 4.20E+04 1.40E+06 0.0300 2.06E+07 0.0020 1.96E+05 0.2143 Cs-134 0.00014 2.93E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.00E+06 3.85E+07 0.0520 5.66E+08 0.0035 5.39E+06 0.3711 Eu-152 0.00599 1.29E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.76E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[85]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 264 P235 Position #47 46 2.14E+06 H-3 1.76 3.50E+06 2.33E+08 0.0150 0.1128 3.42E+09 0.0010 0.0077 3.25E+07 0.1076 0.8065 Co-60 0.06431 1.38E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0064 Ni-63 442 6.08E+07 3.93E+09 0.0155 5.78E+10 0.0011 5.50E+08 0.1106 Sr-90 0.021 4.17E+04 1.40E+06 0.0298 2.06E+07 0.0020 1.96E+05 0.2129 Cs-134 0.00014 2.91E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.99E+06 3.85E+07 0.0516 5.66E+08 0.0035 5.39E+06 0.3687 Eu-152 0.00599 1.28E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.75E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 265 P235 Position #48 47 2.10E+06 H-3 1.76 3.43E+06 2.33E+08 0.0147 0.1108 3.42E+09 0.0010 0.0075 3.25E+07 0.1056 0.7918 Co-60 0.06431 1.35E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0063 Ni-63 442 5.97E+07 3.93E+09 0.0152 5.78E+10 0.0010 5.50E+08 0.1086 Sr-90 0.021 4.10E+04 1.40E+06 0.0293 2.06E+07 0.0020 1.96E+05 0.2090 Cs-134 0.00014 2.86E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.95E+06 3.85E+07 0.0507 5.66E+08 0.0034 5.39E+06 0.3619 Eu-152 0.00599 1.26E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.72E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 266 P235 Position #49 48 2.10E+06 H-3 1.76 3.43E+06 2.33E+08 0.0147 0.1106 3.42E+09 0.0010 0.0075 3.25E+07 0.1055 0.7904 Co-60 0.06431 1.35E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0063 Ni-63 442 5.96E+07 3.93E+09 0.0152 5.78E+10 0.0010 5.50E+08 0.1084 Sr-90 0.021 4.09E+04 1.40E+06 0.0292 2.06E+07 0.0020 1.96E+05 0.2087 Cs-134 0.00014 2.86E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 1.95E+06 3.85E+07 0.0506 5.66E+08 0.0034 5.39E+06 0.3613 Eu-152 0.00599 1.26E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.71E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 267 P235 Position #50 49 2.22E+06 H-3 1.76 3.62E+06 2.33E+08 0.0155 0.1168 3.42E+09 0.0011 0.0079 3.25E+07 0.1114 0.8351 Co-60 0.06431 1.42E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0066 Ni-63 442 6.30E+07 3.93E+09 0.0160 5.78E+10 0.0011 5.50E+08 0.1145 Sr-90 0.021 4.32E+04 1.40E+06 0.0309 2.06E+07 0.0021 1.96E+05 0.2204 Cs-134 0.00014 3.02E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.06E+06 3.85E+07 0.0534 5.66E+08 0.0036 5.39E+06 0.3817 Eu-152 0.00599 1.33E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.81E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 268 P323 Position #1 0

8.55E+06 H-3 1.76 1.40E+07 2.33E+08 0.0600 0.4508 3.42E+09 0.0041 0.0307 3.25E+07 0.4299 3.2222 Co-60 0.06431 5.50E+05 1.54E+08 0.0036 2.26E+09 0.0002 2.15E+07 0.0256 Ni-63 442 2.43E+08 3.93E+09 0.0618 5.78E+10 0.0042 5.50E+08 0.4417 Sr-90 0.021 1.67E+05 1.40E+06 0.1191 2.06E+07 0.0081 1.96E+05 0.8506 Cs-134 0.00014 1.16E+03 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0003 Cs-137 0.92875 7.94E+06 3.85E+07 0.2062 5.66E+08 0.0140 5.39E+06 1.4729 Eu-152 0.00599 5.12E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0010 Eu-154 0.00082 6.99E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0002 269 P323 Position #2 1

1.11E+07 H-3 1.76 1.81E+07 2.33E+08 0.0777 0.5843 3.42E+09 0.0053 0.0397 3.25E+07 0.5572 4.1761 Co-60 0.06431 7.12E+05 1.54E+08 0.0046 2.26E+09 0.0003 2.15E+07 0.0331 Ni-63 442 3.15E+08 3.93E+09 0.0801 5.78E+10 0.0054 5.50E+08 0.5725 Sr-90 0.021 2.16E+05 1.40E+06 0.1543 2.06E+07 0.0105 1.96E+05 1.1024 Cs-134 0.00014 1.51E+03 2.94E+07 0.0001 4.32E+08 0.0000 4.12E+06 0.0004 Cs-137 0.92875 1.03E+07 3.85E+07 0.2673 5.66E+08 0.0182 5.39E+06 1.9089 Eu-152 0.00599 6.64E+04 3.58E+08 0.0002 5.26E+09 0.0000 5.00E+07 0.0013 Eu-154 0.00082 9.06E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0002

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[86]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 270 P323 Position #3 2

4.01E+06 H-3 1.76 6.56E+06 2.33E+08 0.0281 0.2116 3.42E+09 0.0019 0.0144 3.25E+07 0.2018 1.5121 Co-60 0.06431 2.58E+05 1.54E+08 0.0017 2.26E+09 0.0001 2.15E+07 0.0120 Ni-63 442 1.14E+08 3.93E+09 0.0290 5.78E+10 0.0020 5.50E+08 0.2073 Sr-90 0.021 7.82E+04 1.40E+06 0.0559 2.06E+07 0.0038 1.96E+05 0.3992 Cs-134 0.00014 5.47E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.73E+06 3.85E+07 0.0968 5.66E+08 0.0066 5.39E+06 0.6912 Eu-152 0.00599 2.40E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.28E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 271 P323 Position #4 3

3.07E+06 H-3 1.76 5.02E+06 2.33E+08 0.0216 0.1620 3.42E+09 0.0015 0.0110 3.25E+07 0.1545 1.1580 Co-60 0.06431 1.98E+05 1.54E+08 0.0013 2.26E+09 0.0001 2.15E+07 0.0092 Ni-63 442 8.73E+07 3.93E+09 0.0222 5.78E+10 0.0015 5.50E+08 0.1588 Sr-90 0.021 5.99E+04 1.40E+06 0.0428 2.06E+07 0.0029 1.96E+05 0.3057 Cs-134 0.00014 4.19E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.85E+06 3.85E+07 0.0741 5.66E+08 0.0050 5.39E+06 0.5293 Eu-152 0.00599 1.84E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.51E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 272 P323 Position #5 4

3.19E+06 H-3 1.76 5.22E+06 2.33E+08 0.0224 0.1683 3.42E+09 0.0015 0.0114 3.25E+07 0.1605 1.2028 Co-60 0.06431 2.05E+05 1.54E+08 0.0013 2.26E+09 0.0001 2.15E+07 0.0095 Ni-63 442 9.07E+07 3.93E+09 0.0231 5.78E+10 0.0016 5.50E+08 0.1649 Sr-90 0.021 6.22E+04 1.40E+06 0.0445 2.06E+07 0.0030 1.96E+05 0.3175 Cs-134 0.00014 4.35E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.96E+06 3.85E+07 0.0770 5.66E+08 0.0052 5.39E+06 0.5498 Eu-152 0.00599 1.91E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.61E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 273 P323 Position #6 5

3.72E+06 H-3 1.76 6.08E+06 2.33E+08 0.0261 0.1963 3.42E+09 0.0018 0.0133 3.25E+07 0.1872 1.4027 Co-60 0.06431 2.39E+05 1.54E+08 0.0016 2.26E+09 0.0001 2.15E+07 0.0111 Ni-63 442 1.06E+08 3.93E+09 0.0269 5.78E+10 0.0018 5.50E+08 0.1923 Sr-90 0.021 7.26E+04 1.40E+06 0.0518 2.06E+07 0.0035 1.96E+05 0.3703 Cs-134 0.00014 5.07E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.46E+06 3.85E+07 0.0898 5.66E+08 0.0061 5.39E+06 0.6412 Eu-152 0.00599 2.23E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 3.04E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 274 P323 Position #7 6

3.74E+06 H-3 1.76 6.12E+06 2.33E+08 0.0262 0.1973 3.42E+09 0.0018 0.0134 3.25E+07 0.1882 1.4102 Co-60 0.06431 2.41E+05 1.54E+08 0.0016 2.26E+09 0.0001 2.15E+07 0.0112 Ni-63 442 1.06E+08 3.93E+09 0.0271 5.78E+10 0.0018 5.50E+08 0.1933 Sr-90 0.021 7.30E+04 1.40E+06 0.0521 2.06E+07 0.0035 1.96E+05 0.3723 Cs-134 0.00014 5.10E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.47E+06 3.85E+07 0.0902 5.66E+08 0.0061 5.39E+06 0.6446 Eu-152 0.00599 2.24E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 3.06E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 275 P323 Position #8 7

3.84E+06 H-3 1.76 6.28E+06 2.33E+08 0.0269 0.2025 3.42E+09 0.0018 0.0138 3.25E+07 0.1931 1.4473 Co-60 0.06431 2.47E+05 1.54E+08 0.0016 2.26E+09 0.0001 2.15E+07 0.0115 Ni-63 442 1.09E+08 3.93E+09 0.0278 5.78E+10 0.0019 5.50E+08 0.1984 Sr-90 0.021 7.49E+04 1.40E+06 0.0535 2.06E+07 0.0036 1.96E+05 0.3821 Cs-134 0.00014 5.23E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.57E+06 3.85E+07 0.0926 5.66E+08 0.0063 5.39E+06 0.6616 Eu-152 0.00599 2.30E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.14E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[87]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 276 P323 Position #9 8

4.75E+06 H-3 1.76 7.77E+06 2.33E+08 0.0334 0.2508 3.42E+09 0.0023 0.0171 3.25E+07 0.2391 1.7923 Co-60 0.06431 3.06E+05 1.54E+08 0.0020 2.26E+09 0.0001 2.15E+07 0.0142 Ni-63 442 1.35E+08 3.93E+09 0.0344 5.78E+10 0.0023 5.50E+08 0.2457 Sr-90 0.021 9.27E+04 1.40E+06 0.0662 2.06E+07 0.0045 1.96E+05 0.4731 Cs-134 0.00014 6.48E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 4.42E+06 3.85E+07 0.1147 5.66E+08 0.0078 5.39E+06 0.8193 Eu-152 0.00599 2.85E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0006 Eu-154 0.00082 3.89E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 277 P323 Position #10 9

4.59E+06 H-3 1.76 7.51E+06 2.33E+08 0.0322 0.2422 3.42E+09 0.0022 0.0165 3.25E+07 0.2310 1.7312 Co-60 0.06431 2.95E+05 1.54E+08 0.0019 2.26E+09 0.0001 2.15E+07 0.0137 Ni-63 442 1.31E+08 3.93E+09 0.0332 5.78E+10 0.0023 5.50E+08 0.2373 Sr-90 0.021 8.96E+04 1.40E+06 0.0640 2.06E+07 0.0043 1.96E+05 0.4570 Cs-134 0.00014 6.26E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 4.27E+06 3.85E+07 0.1108 5.66E+08 0.0075 5.39E+06 0.7913 Eu-152 0.00599 2.75E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0006 Eu-154 0.00082 3.75E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 278 P323 Position #11 10 3.31E+06 H-3 1.76 5.41E+06 2.33E+08 0.0232 0.1746 3.42E+09 0.0016 0.0119 3.25E+07 0.1665 1.2481 Co-60 0.06431 2.13E+05 1.54E+08 0.0014 2.26E+09 0.0001 2.15E+07 0.0099 Ni-63 442 9.41E+07 3.93E+09 0.0239 5.78E+10 0.0016 5.50E+08 0.1711 Sr-90 0.021 6.46E+04 1.40E+06 0.0461 2.06E+07 0.0031 1.96E+05 0.3295 Cs-134 0.00014 4.51E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.08E+06 3.85E+07 0.0799 5.66E+08 0.0054 5.39E+06 0.5705 Eu-152 0.00599 1.98E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.71E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 279 P323 Position #12 11 2.94E+06 H-3 1.76 4.81E+06 2.33E+08 0.0207 0.1553 3.42E+09 0.0014 0.0106 3.25E+07 0.1481 1.1097 Co-60 0.06431 1.89E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0088 Ni-63 442 8.37E+07 3.93E+09 0.0213 5.78E+10 0.0014 5.50E+08 0.1521 Sr-90 0.021 5.74E+04 1.40E+06 0.0410 2.06E+07 0.0028 1.96E+05 0.2930 Cs-134 0.00014 4.01E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.73E+06 3.85E+07 0.0710 5.66E+08 0.0048 5.39E+06 0.5073 Eu-152 0.00599 1.76E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.41E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 280 P323 Position #13 12 2.84E+06 H-3 1.76 4.64E+06 2.33E+08 0.0199 0.1498 3.42E+09 0.0014 0.0102 3.25E+07 0.1429 1.0707 Co-60 0.06431 1.83E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0085 Ni-63 442 8.07E+07 3.93E+09 0.0205 5.78E+10 0.0014 5.50E+08 0.1468 Sr-90 0.021 5.54E+04 1.40E+06 0.0396 2.06E+07 0.0027 1.96E+05 0.2826 Cs-134 0.00014 3.87E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.64E+06 3.85E+07 0.0685 5.66E+08 0.0047 5.39E+06 0.4894 Eu-152 0.00599 1.70E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.32E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 281 P323 Position #14 13 2.75E+06 H-3 1.76 4.49E+06 2.33E+08 0.0193 0.1448 3.42E+09 0.0013 0.0099 3.25E+07 0.1381 1.0351 Co-60 0.06431 1.77E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0082 Ni-63 442 7.80E+07 3.93E+09 0.0199 5.78E+10 0.0014 5.50E+08 0.1419 Sr-90 0.021 5.36E+04 1.40E+06 0.0383 2.06E+07 0.0026 1.96E+05 0.2732 Cs-134 0.00014 3.74E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.55E+06 3.85E+07 0.0662 5.66E+08 0.0045 5.39E+06 0.4732 Eu-152 0.00599 1.65E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.24E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[88]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 282 P323 Position #15 14 2.77E+06 H-3 1.76 4.53E+06 2.33E+08 0.0194 0.1461 3.42E+09 0.0013 0.0099 3.25E+07 0.1393 1.0442 Co-60 0.06431 1.78E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0083 Ni-63 442 7.87E+07 3.93E+09 0.0200 5.78E+10 0.0014 5.50E+08 0.1432 Sr-90 0.021 5.40E+04 1.40E+06 0.0386 2.06E+07 0.0026 1.96E+05 0.2756 Cs-134 0.00014 3.77E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.57E+06 3.85E+07 0.0668 5.66E+08 0.0045 5.39E+06 0.4773 Eu-152 0.00599 1.66E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.26E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 283 P323 Position #16 15 2.81E+06 H-3 1.76 4.59E+06 2.33E+08 0.0197 0.1480 3.42E+09 0.0013 0.0101 3.25E+07 0.1412 1.0580 Co-60 0.06431 1.80E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0084 Ni-63 442 7.98E+07 3.93E+09 0.0203 5.78E+10 0.0014 5.50E+08 0.1450 Sr-90 0.021 5.47E+04 1.40E+06 0.0391 2.06E+07 0.0027 1.96E+05 0.2793 Cs-134 0.00014 3.82E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.61E+06 3.85E+07 0.0677 5.66E+08 0.0046 5.39E+06 0.4836 Eu-152 0.00599 1.68E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.29E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 284 P323 Position #17 16 3.29E+06 H-3 1.76 5.38E+06 2.33E+08 0.0231 0.1735 3.42E+09 0.0016 0.0118 3.25E+07 0.1654 1.2398 Co-60 0.06431 2.11E+05 1.54E+08 0.0014 2.26E+09 0.0001 2.15E+07 0.0098 Ni-63 442 9.35E+07 3.93E+09 0.0238 5.78E+10 0.0016 5.50E+08 0.1700 Sr-90 0.021 6.41E+04 1.40E+06 0.0458 2.06E+07 0.0031 1.96E+05 0.3273 Cs-134 0.00014 4.48E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.05E+06 3.85E+07 0.0793 5.66E+08 0.0054 5.39E+06 0.5667 Eu-152 0.00599 1.97E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.69E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 285 P323 Position #18 17 4.82E+06 H-3 1.76 7.88E+06 2.33E+08 0.0338 0.2543 3.42E+09 0.0023 0.0173 3.25E+07 0.2425 1.8176 Co-60 0.06431 3.10E+05 1.54E+08 0.0020 2.26E+09 0.0001 2.15E+07 0.0144 Ni-63 442 1.37E+08 3.93E+09 0.0349 5.78E+10 0.0024 5.50E+08 0.2492 Sr-90 0.021 9.40E+04 1.40E+06 0.0672 2.06E+07 0.0046 1.96E+05 0.4798 Cs-134 0.00014 6.57E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 4.48E+06 3.85E+07 0.1163 5.66E+08 0.0079 5.39E+06 0.8308 Eu-152 0.00599 2.89E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0006 Eu-154 0.00082 3.94E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 286 P323 Position #19 18 3.69E+06 H-3 1.76 6.04E+06 2.33E+08 0.0259 0.1948 3.42E+09 0.0018 0.0133 3.25E+07 0.1858 1.3925 Co-60 0.06431 2.38E+05 1.54E+08 0.0015 2.26E+09 0.0001 2.15E+07 0.0110 Ni-63 442 1.05E+08 3.93E+09 0.0267 5.78E+10 0.0018 5.50E+08 0.1909 Sr-90 0.021 7.20E+04 1.40E+06 0.0515 2.06E+07 0.0035 1.96E+05 0.3676 Cs-134 0.00014 5.03E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.43E+06 3.85E+07 0.0891 5.66E+08 0.0061 5.39E+06 0.6365 Eu-152 0.00599 2.21E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 3.02E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 287 P323 Position #20 19 3.03E+06 H-3 1.76 4.95E+06 2.33E+08 0.0212 0.1597 3.42E+09 0.0014 0.0109 3.25E+07 0.1522 1.1410 Co-60 0.06431 1.95E+05 1.54E+08 0.0013 2.26E+09 0.0001 2.15E+07 0.0091 Ni-63 442 8.60E+07 3.93E+09 0.0219 5.78E+10 0.0015 5.50E+08 0.1564 Sr-90 0.021 5.90E+04 1.40E+06 0.0422 2.06E+07 0.0029 1.96E+05 0.3012 Cs-134 0.00014 4.12E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.81E+06 3.85E+07 0.0730 5.66E+08 0.0050 5.39E+06 0.5216 Eu-152 0.00599 1.81E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.47E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[89]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 288 P323 Position #21 20 2.80E+06 H-3 1.76 4.58E+06 2.33E+08 0.0197 0.1478 3.42E+09 0.0013 0.0101 3.25E+07 0.1409 1.0561 Co-60 0.06431 1.80E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0084 Ni-63 442 7.96E+07 3.93E+09 0.0203 5.78E+10 0.0014 5.50E+08 0.1448 Sr-90 0.021 5.46E+04 1.40E+06 0.0390 2.06E+07 0.0027 1.96E+05 0.2788 Cs-134 0.00014 3.82E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.60E+06 3.85E+07 0.0676 5.66E+08 0.0046 5.39E+06 0.4828 Eu-152 0.00599 1.68E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.29E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 289 P323 Position #22 21 2.49E+06 H-3 1.76 4.07E+06 2.33E+08 0.0175 0.1313 3.42E+09 0.0012 0.0089 3.25E+07 0.1252 0.9383 Co-60 0.06431 1.60E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0074 Ni-63 442 7.07E+07 3.93E+09 0.0180 5.78E+10 0.0012 5.50E+08 0.1286 Sr-90 0.021 4.85E+04 1.40E+06 0.0347 2.06E+07 0.0024 1.96E+05 0.2477 Cs-134 0.00014 3.39E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.31E+06 3.85E+07 0.0600 5.66E+08 0.0041 5.39E+06 0.4289 Eu-152 0.00599 1.49E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.03E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 290 P323 Position #23 22 2.46E+06 H-3 1.76 4.02E+06 2.33E+08 0.0173 0.1297 3.42E+09 0.0012 0.0088 3.25E+07 0.1237 0.9271 Co-60 0.06431 1.58E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0074 Ni-63 442 6.99E+07 3.93E+09 0.0178 5.78E+10 0.0012 5.50E+08 0.1271 Sr-90 0.021 4.80E+04 1.40E+06 0.0343 2.06E+07 0.0023 1.96E+05 0.2447 Cs-134 0.00014 3.35E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.28E+06 3.85E+07 0.0593 5.66E+08 0.0040 5.39E+06 0.4238 Eu-152 0.00599 1.47E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.01E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 291 P323 Position #24 23 2.37E+06 H-3 1.76 3.87E+06 2.33E+08 0.0166 0.1249 3.42E+09 0.0011 0.0085 3.25E+07 0.1191 0.8929 Co-60 0.06431 1.52E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0071 Ni-63 442 6.73E+07 3.93E+09 0.0171 5.78E+10 0.0012 5.50E+08 0.1224 Sr-90 0.021 4.62E+04 1.40E+06 0.0330 2.06E+07 0.0022 1.96E+05 0.2357 Cs-134 0.00014 3.23E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.20E+06 3.85E+07 0.0571 5.66E+08 0.0039 5.39E+06 0.4082 Eu-152 0.00599 1.42E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.94E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 292 P323 Position #25 24 2.30E+06 H-3 1.76 3.76E+06 2.33E+08 0.0161 0.1214 3.42E+09 0.0011 0.0083 3.25E+07 0.1157 0.8674 Co-60 0.06431 1.48E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0069 Ni-63 442 6.54E+07 3.93E+09 0.0166 5.78E+10 0.0011 5.50E+08 0.1189 Sr-90 0.021 4.49E+04 1.40E+06 0.0321 2.06E+07 0.0022 1.96E+05 0.2290 Cs-134 0.00014 3.13E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.14E+06 3.85E+07 0.0555 5.66E+08 0.0038 5.39E+06 0.3965 Eu-152 0.00599 1.38E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.88E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 293 P323 Position #26 25 2.51E+06 H-3 1.76 4.11E+06 2.33E+08 0.0176 0.1326 3.42E+09 0.0012 0.0090 3.25E+07 0.1265 0.9479 Co-60 0.06431 1.62E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0075 Ni-63 442 7.15E+07 3.93E+09 0.0182 5.78E+10 0.0012 5.50E+08 0.1299 Sr-90 0.021 4.90E+04 1.40E+06 0.0350 2.06E+07 0.0024 1.96E+05 0.2502 Cs-134 0.00014 3.43E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.34E+06 3.85E+07 0.0607 5.66E+08 0.0041 5.39E+06 0.4333 Eu-152 0.00599 1.51E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.06E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[90]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 294 P323 Position #27 26 3.25E+06 H-3 1.76 5.31E+06 2.33E+08 0.0228 0.1714 3.42E+09 0.0016 0.0117 3.25E+07 0.1634 1.2249 Co-60 0.06431 2.09E+05 1.54E+08 0.0014 2.26E+09 0.0001 2.15E+07 0.0097 Ni-63 442 9.24E+07 3.93E+09 0.0235 5.78E+10 0.0016 5.50E+08 0.1679 Sr-90 0.021 6.34E+04 1.40E+06 0.0453 2.06E+07 0.0031 1.96E+05 0.3233 Cs-134 0.00014 4.43E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.02E+06 3.85E+07 0.0784 5.66E+08 0.0053 5.39E+06 0.5599 Eu-152 0.00599 1.95E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 295 P323 Position #28 27 2.82E+06 H-3 1.76 4.62E+06 2.33E+08 0.0198 0.1490 3.42E+09 0.0014 0.0101 3.25E+07 0.1421 1.0647 Co-60 0.06431 1.82E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0084 Ni-63 442 8.03E+07 3.93E+09 0.0204 5.78E+10 0.0014 5.50E+08 0.1460 Sr-90 0.021 5.51E+04 1.40E+06 0.0393 2.06E+07 0.0027 1.96E+05 0.2811 Cs-134 0.00014 3.85E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.62E+06 3.85E+07 0.0681 5.66E+08 0.0046 5.39E+06 0.4867 Eu-152 0.00599 1.69E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.31E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 296 P323 Position #29 28 2.81E+06 H-3 1.76 4.59E+06 2.33E+08 0.0197 0.1481 3.42E+09 0.0013 0.0101 3.25E+07 0.1412 1.0584 Co-60 0.06431 1.81E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0084 Ni-63 442 7.98E+07 3.93E+09 0.0203 5.78E+10 0.0014 5.50E+08 0.1451 Sr-90 0.021 5.48E+04 1.40E+06 0.0391 2.06E+07 0.0027 1.96E+05 0.2794 Cs-134 0.00014 3.83E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.61E+06 3.85E+07 0.0677 5.66E+08 0.0046 5.39E+06 0.4838 Eu-152 0.00599 1.68E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.30E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 297 P323 Position #30 29 2.45E+06 H-3 1.76 4.00E+06 2.33E+08 0.0172 0.1291 3.42E+09 0.0012 0.0088 3.25E+07 0.1231 0.9228 Co-60 0.06431 1.57E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.96E+07 3.93E+09 0.0177 5.78E+10 0.0012 5.50E+08 0.1265 Sr-90 0.021 4.77E+04 1.40E+06 0.0341 2.06E+07 0.0023 1.96E+05 0.2436 Cs-134 0.00014 3.34E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.27E+06 3.85E+07 0.0591 5.66E+08 0.0040 5.39E+06 0.4218 Eu-152 0.00599 1.47E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.00E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 298 P323 Position #31 30 2.31E+06 H-3 1.76 3.78E+06 2.33E+08 0.0162 0.1220 3.42E+09 0.0011 0.0083 3.25E+07 0.1163 0.8719 Co-60 0.06431 1.49E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0069 Ni-63 442 6.57E+07 3.93E+09 0.0167 5.78E+10 0.0011 5.50E+08 0.1195 Sr-90 0.021 4.51E+04 1.40E+06 0.0322 2.06E+07 0.0022 1.96E+05 0.2302 Cs-134 0.00014 3.15E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.15E+06 3.85E+07 0.0558 5.66E+08 0.0038 5.39E+06 0.3986 Eu-152 0.00599 1.39E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.89E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 299 P323 Position #32 31 2.32E+06 H-3 1.76 3.79E+06 2.33E+08 0.0162 0.1222 3.42E+09 0.0011 0.0083 3.25E+07 0.1165 0.8731 Co-60 0.06431 1.49E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0069 Ni-63 442 6.58E+07 3.93E+09 0.0168 5.78E+10 0.0011 5.50E+08 0.1197 Sr-90 0.021 4.52E+04 1.40E+06 0.0323 2.06E+07 0.0022 1.96E+05 0.2305 Cs-134 0.00014 3.16E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.15E+06 3.85E+07 0.0559 5.66E+08 0.0038 5.39E+06 0.3991 Eu-152 0.00599 1.39E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.89E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[91]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 300 P323 Position #33 32 2.32E+06 H-3 1.76 3.79E+06 2.33E+08 0.0163 0.1223 3.42E+09 0.0011 0.0083 3.25E+07 0.1166 0.8739 Co-60 0.06431 1.49E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0069 Ni-63 442 6.59E+07 3.93E+09 0.0168 5.78E+10 0.0011 5.50E+08 0.1198 Sr-90 0.021 4.52E+04 1.40E+06 0.0323 2.06E+07 0.0022 1.96E+05 0.2307 Cs-134 0.00014 3.16E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.15E+06 3.85E+07 0.0559 5.66E+08 0.0038 5.39E+06 0.3995 Eu-152 0.00599 1.39E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.90E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 301 P323 Position #34 33 2.33E+06 H-3 1.76 3.80E+06 2.33E+08 0.0163 0.1227 3.42E+09 0.0011 0.0083 3.25E+07 0.1170 0.8767 Co-60 0.06431 1.50E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0070 Ni-63 442 6.61E+07 3.93E+09 0.0168 5.78E+10 0.0011 5.50E+08 0.1202 Sr-90 0.021 4.54E+04 1.40E+06 0.0324 2.06E+07 0.0022 1.96E+05 0.2314 Cs-134 0.00014 3.17E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.16E+06 3.85E+07 0.0561 5.66E+08 0.0038 5.39E+06 0.4008 Eu-152 0.00599 1.39E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.90E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 302 P323 Position #35 34 2.54E+06 H-3 1.76 4.15E+06 2.33E+08 0.0178 0.1338 3.42E+09 0.0012 0.0091 3.25E+07 0.1276 0.9563 Co-60 0.06431 1.63E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0076 Ni-63 442 7.21E+07 3.93E+09 0.0183 5.78E+10 0.0012 5.50E+08 0.1311 Sr-90 0.021 4.95E+04 1.40E+06 0.0353 2.06E+07 0.0024 1.96E+05 0.2524 Cs-134 0.00014 3.46E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.36E+06 3.85E+07 0.0612 5.66E+08 0.0042 5.39E+06 0.4371 Eu-152 0.00599 1.52E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.07E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 303 P323 Position #36 35 3.16E+06 H-3 1.76 5.16E+06 2.33E+08 0.0222 0.1666 3.42E+09 0.0015 0.0113 3.25E+07 0.1589 1.1909 Co-60 0.06431 2.03E+05 1.54E+08 0.0013 2.26E+09 0.0001 2.15E+07 0.0094 Ni-63 442 8.98E+07 3.93E+09 0.0228 5.78E+10 0.0016 5.50E+08 0.1633 Sr-90 0.021 6.16E+04 1.40E+06 0.0440 2.06E+07 0.0030 1.96E+05 0.3144 Cs-134 0.00014 4.30E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.93E+06 3.85E+07 0.0762 5.66E+08 0.0052 5.39E+06 0.5444 Eu-152 0.00599 1.89E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.58E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 304 P323 Position #37 36 2.65E+06 H-3 1.76 4.33E+06 2.33E+08 0.0186 0.1396 3.42E+09 0.0013 0.0095 3.25E+07 0.1331 0.9977 Co-60 0.06431 1.70E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0079 Ni-63 442 7.52E+07 3.93E+09 0.0191 5.78E+10 0.0013 5.50E+08 0.1368 Sr-90 0.021 5.16E+04 1.40E+06 0.0369 2.06E+07 0.0025 1.96E+05 0.2634 Cs-134 0.00014 3.61E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.46E+06 3.85E+07 0.0638 5.66E+08 0.0043 5.39E+06 0.4560 Eu-152 0.00599 1.59E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.16E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 305 P323 Position #38 37 2.56E+06 H-3 1.76 4.18E+06 2.33E+08 0.0180 0.1350 3.42E+09 0.0012 0.0092 3.25E+07 0.1287 0.9647 Co-60 0.06431 1.65E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0077 Ni-63 442 7.27E+07 3.93E+09 0.0185 5.78E+10 0.0013 5.50E+08 0.1322 Sr-90 0.021 4.99E+04 1.40E+06 0.0357 2.06E+07 0.0024 1.96E+05 0.2547 Cs-134 0.00014 3.49E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.38E+06 3.85E+07 0.0617 5.66E+08 0.0042 5.39E+06 0.4410 Eu-152 0.00599 1.53E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.09E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[92]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 306 P323 Position #39 38 2.43E+06 H-3 1.76 3.98E+06 2.33E+08 0.0171 0.1284 3.42E+09 0.0012 0.0087 3.25E+07 0.1224 0.9174 Co-60 0.06431 1.57E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.92E+07 3.93E+09 0.0176 5.78E+10 0.0012 5.50E+08 0.1258 Sr-90 0.021 4.75E+04 1.40E+06 0.0339 2.06E+07 0.0023 1.96E+05 0.2422 Cs-134 0.00014 3.32E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.26E+06 3.85E+07 0.0587 5.66E+08 0.0040 5.39E+06 0.4194 Eu-152 0.00599 1.46E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.99E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 307 P323 Position #40 39 2.44E+06 H-3 1.76 3.99E+06 2.33E+08 0.0171 0.1288 3.42E+09 0.0012 0.0088 3.25E+07 0.1228 0.9206 Co-60 0.06431 1.57E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.94E+07 3.93E+09 0.0177 5.78E+10 0.0012 5.50E+08 0.1262 Sr-90 0.021 4.76E+04 1.40E+06 0.0340 2.06E+07 0.0023 1.96E+05 0.2430 Cs-134 0.00014 3.33E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.27E+06 3.85E+07 0.0589 5.66E+08 0.0040 5.39E+06 0.4208 Eu-152 0.00599 1.46E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.00E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 308 P323 Position #41 40 2.50E+06 H-3 1.76 4.09E+06 2.33E+08 0.0175 0.1318 3.42E+09 0.0012 0.0090 3.25E+07 0.1257 0.9421 Co-60 0.06431 1.61E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0075 Ni-63 442 7.10E+07 3.93E+09 0.0181 5.78E+10 0.0012 5.50E+08 0.1292 Sr-90 0.021 4.87E+04 1.40E+06 0.0348 2.06E+07 0.0024 1.96E+05 0.2487 Cs-134 0.00014 3.41E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.32E+06 3.85E+07 0.0603 5.66E+08 0.0041 5.39E+06 0.4307 Eu-152 0.00599 1.50E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.04E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 309 P323 Position #42 41 2.50E+06 H-3 1.76 4.09E+06 2.33E+08 0.0175 0.1318 3.42E+09 0.0012 0.0090 3.25E+07 0.1257 0.9421 Co-60 0.06431 1.61E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0075 Ni-63 442 7.10E+07 3.93E+09 0.0181 5.78E+10 0.0012 5.50E+08 0.1292 Sr-90 0.021 4.87E+04 1.40E+06 0.0348 2.06E+07 0.0024 1.96E+05 0.2487 Cs-134 0.00014 3.41E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.32E+06 3.85E+07 0.0603 5.66E+08 0.0041 5.39E+06 0.4307 Eu-152 0.00599 1.50E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.04E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 310 P323 Position #43 42 2.53E+06 H-3 1.76 4.14E+06 2.33E+08 0.0177 0.1334 3.42E+09 0.0012 0.0091 3.25E+07 0.1272 0.9537 Co-60 0.06431 1.63E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0076 Ni-63 442 7.19E+07 3.93E+09 0.0183 5.78E+10 0.0012 5.50E+08 0.1307 Sr-90 0.021 4.93E+04 1.40E+06 0.0352 2.06E+07 0.0024 1.96E+05 0.2518 Cs-134 0.00014 3.45E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.35E+06 3.85E+07 0.0610 5.66E+08 0.0042 5.39E+06 0.4359 Eu-152 0.00599 1.52E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.07E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 311 P323 Position #44 43 2.61E+06 H-3 1.76 4.27E+06 2.33E+08 0.0183 0.1379 3.42E+09 0.0012 0.0094 3.25E+07 0.1315 0.9854 Co-60 0.06431 1.68E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0078 Ni-63 442 7.43E+07 3.93E+09 0.0189 5.78E+10 0.0013 5.50E+08 0.1351 Sr-90 0.021 5.10E+04 1.40E+06 0.0364 2.06E+07 0.0025 1.96E+05 0.2601 Cs-134 0.00014 3.56E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.43E+06 3.85E+07 0.0631 5.66E+08 0.0043 5.39E+06 0.4504 Eu-152 0.00599 1.57E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.14E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[93]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 312 P323 Position #45 44 2.77E+06 H-3 1.76 4.53E+06 2.33E+08 0.0194 0.1462 3.42E+09 0.0013 0.0099 3.25E+07 0.1394 1.0447 Co-60 0.06431 1.78E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0083 Ni-63 442 7.88E+07 3.93E+09 0.0200 5.78E+10 0.0014 5.50E+08 0.1432 Sr-90 0.021 5.41E+04 1.40E+06 0.0386 2.06E+07 0.0026 1.96E+05 0.2758 Cs-134 0.00014 3.78E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.57E+06 3.85E+07 0.0669 5.66E+08 0.0045 5.39E+06 0.4775 Eu-152 0.00599 1.66E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.27E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 313 P323 Position #46 45 4.03E+06 H-3 1.76 6.59E+06 2.33E+08 0.0283 0.2128 3.42E+09 0.0019 0.0145 3.25E+07 0.2029 1.5208 Co-60 0.06431 2.59E+05 1.54E+08 0.0017 2.26E+09 0.0001 2.15E+07 0.0121 Ni-63 442 1.15E+08 3.93E+09 0.0292 5.78E+10 0.0020 5.50E+08 0.2085 Sr-90 0.021 7.87E+04 1.40E+06 0.0562 2.06E+07 0.0038 1.96E+05 0.4015 Cs-134 0.00014 5.50E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.75E+06 3.85E+07 0.0973 5.66E+08 0.0066 5.39E+06 0.6952 Eu-152 0.00599 2.42E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.30E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 314 P323 Position #47 46 3.92E+06 H-3 1.76 6.41E+06 2.33E+08 0.0275 0.2067 3.42E+09 0.0019 0.0141 3.25E+07 0.1971 1.4775 Co-60 0.06431 2.52E+05 1.54E+08 0.0016 2.26E+09 0.0001 2.15E+07 0.0117 Ni-63 442 1.11E+08 3.93E+09 0.0283 5.78E+10 0.0019 5.50E+08 0.2026 Sr-90 0.021 7.64E+04 1.40E+06 0.0546 2.06E+07 0.0037 1.96E+05 0.3900 Cs-134 0.00014 5.34E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.64E+06 3.85E+07 0.0946 5.66E+08 0.0064 5.39E+06 0.6754 Eu-152 0.00599 2.35E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.20E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 315 P323 Position #48 47 3.26E+06 H-3 1.76 5.33E+06 2.33E+08 0.0229 0.1720 3.42E+09 0.0016 0.0117 3.25E+07 0.1640 1.2289 Co-60 0.06431 2.10E+05 1.54E+08 0.0014 2.26E+09 0.0001 2.15E+07 0.0098 Ni-63 442 9.27E+07 3.93E+09 0.0236 5.78E+10 0.0016 5.50E+08 0.1685 Sr-90 0.021 6.36E+04 1.40E+06 0.0454 2.06E+07 0.0031 1.96E+05 0.3244 Cs-134 0.00014 4.44E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.03E+06 3.85E+07 0.0786 5.66E+08 0.0053 5.39E+06 0.5618 Eu-152 0.00599 1.95E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.67E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 316 P323 Position #49 48 3.11E+06 H-3 1.76 5.09E+06 2.33E+08 0.0218 0.1641 3.42E+09 0.0015 0.0112 3.25E+07 0.1565 1.1730 Co-60 0.06431 2.00E+05 1.54E+08 0.0013 2.26E+09 0.0001 2.15E+07 0.0093 Ni-63 442 8.84E+07 3.93E+09 0.0225 5.78E+10 0.0015 5.50E+08 0.1608 Sr-90 0.021 6.07E+04 1.40E+06 0.0433 2.06E+07 0.0029 1.96E+05 0.3096 Cs-134 0.00014 4.24E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.89E+06 3.85E+07 0.0751 5.66E+08 0.0051 5.39E+06 0.5362 Eu-152 0.00599 1.87E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.54E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 317 P323 Position #50 49 3.41E+06 H-3 1.76 5.58E+06 2.33E+08 0.0240 0.1801 3.42E+09 0.0016 0.0122 3.25E+07 0.1717 1.2871 Co-60 0.06431 2.20E+05 1.54E+08 0.0014 2.26E+09 0.0001 2.15E+07 0.0102 Ni-63 442 9.71E+07 3.93E+09 0.0247 5.78E+10 0.0017 5.50E+08 0.1765 Sr-90 0.021 6.66E+04 1.40E+06 0.0476 2.06E+07 0.0032 1.96E+05 0.3398 Cs-134 0.00014 4.65E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.17E+06 3.85E+07 0.0824 5.66E+08 0.0056 5.39E+06 0.5884 Eu-152 0.00599 2.05E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.79E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[94]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 318 P323 Position #1 50 2.71E+06 H-3 1.76 4.43E+06 2.33E+08 0.0190 0.1429 3.42E+09 0.0013 0.0097 3.25E+07 0.1362 1.0210 Co-60 0.06431 1.74E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0081 Ni-63 442 7.70E+07 3.93E+09 0.0196 5.78E+10 0.0013 5.50E+08 0.1400 Sr-90 0.021 5.28E+04 1.40E+06 0.0377 2.06E+07 0.0026 1.96E+05 0.2695 Cs-134 0.00014 3.69E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.52E+06 3.85E+07 0.0653 5.66E+08 0.0044 5.39E+06 0.4667 Eu-152 0.00599 1.62E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.21E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 319 P324 Position #1 0

7.18E+06 H-3 1.76 1.17E+07 2.33E+08 0.0504 0.3788 3.42E+09 0.0034 0.0258 3.25E+07 0.3612 2.7069 Co-60 0.06431 4.62E+05 1.54E+08 0.0030 2.26E+09 0.0002 2.15E+07 0.0215 Ni-63 442 2.04E+08 3.93E+09 0.0519 5.78E+10 0.0035 5.50E+08 0.3711 Sr-90 0.021 1.40E+05 1.40E+06 0.1000 2.06E+07 0.0068 1.96E+05 0.7146 Cs-134 0.00014 9.78E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 6.67E+06 3.85E+07 0.1732 5.66E+08 0.0118 5.39E+06 1.2373 Eu-152 0.00599 4.30E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0009 Eu-154 0.00082 5.87E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 320 P324 Position #2 1

3.25E+06 H-3 1.76 5.31E+06 2.33E+08 0.0228 0.1714 3.42E+09 0.0016 0.0117 3.25E+07 0.1634 1.2249 Co-60 0.06431 2.09E+05 1.54E+08 0.0014 2.26E+09 0.0001 2.15E+07 0.0097 Ni-63 442 9.24E+07 3.93E+09 0.0235 5.78E+10 0.0016 5.50E+08 0.1679 Sr-90 0.021 6.34E+04 1.40E+06 0.0453 2.06E+07 0.0031 1.96E+05 0.3233 Cs-134 0.00014 4.43E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.02E+06 3.85E+07 0.0784 5.66E+08 0.0053 5.39E+06 0.5599 Eu-152 0.00599 1.95E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.66E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 321 P324 Position #3 2

2.58E+06 H-3 1.76 4.22E+06 2.33E+08 0.0181 0.1360 3.42E+09 0.0012 0.0093 3.25E+07 0.1297 0.9721 Co-60 0.06431 1.66E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0077 Ni-63 442 7.33E+07 3.93E+09 0.0187 5.78E+10 0.0013 5.50E+08 0.1333 Sr-90 0.021 5.03E+04 1.40E+06 0.0359 2.06E+07 0.0024 1.96E+05 0.2566 Cs-134 0.00014 3.51E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.40E+06 3.85E+07 0.0622 5.66E+08 0.0042 5.39E+06 0.4444 Eu-152 0.00599 1.55E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.11E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 322 P324 Position #4 3

2.65E+06 H-3 1.76 4.34E+06 2.33E+08 0.0186 0.1400 3.42E+09 0.0013 0.0095 3.25E+07 0.1335 1.0006 Co-60 0.06431 1.71E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0079 Ni-63 442 7.54E+07 3.93E+09 0.0192 5.78E+10 0.0013 5.50E+08 0.1372 Sr-90 0.021 5.18E+04 1.40E+06 0.0370 2.06E+07 0.0025 1.96E+05 0.2641 Cs-134 0.00014 3.62E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.47E+06 3.85E+07 0.0640 5.66E+08 0.0044 5.39E+06 0.4574 Eu-152 0.00599 1.59E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.17E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 323 P324 Position #5 4

2.63E+06 H-3 1.76 4.30E+06 2.33E+08 0.0184 0.1386 3.42E+09 0.0013 0.0094 3.25E+07 0.1322 0.9909 Co-60 0.06431 1.69E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0079 Ni-63 442 7.47E+07 3.93E+09 0.0190 5.78E+10 0.0013 5.50E+08 0.1358 Sr-90 0.021 5.13E+04 1.40E+06 0.0366 2.06E+07 0.0025 1.96E+05 0.2616 Cs-134 0.00014 3.58E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.44E+06 3.85E+07 0.0634 5.66E+08 0.0043 5.39E+06 0.4529 Eu-152 0.00599 1.58E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.15E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[95]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 324 P324 Position #6 5

2.53E+06 H-3 1.76 4.13E+06 2.33E+08 0.0177 0.1332 3.42E+09 0.0012 0.0091 3.25E+07 0.1270 0.9518 Co-60 0.06431 1.62E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0076 Ni-63 442 7.18E+07 3.93E+09 0.0183 5.78E+10 0.0012 5.50E+08 0.1305 Sr-90 0.021 4.92E+04 1.40E+06 0.0352 2.06E+07 0.0024 1.96E+05 0.2513 Cs-134 0.00014 3.44E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.35E+06 3.85E+07 0.0609 5.66E+08 0.0041 5.39E+06 0.4351 Eu-152 0.00599 1.51E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.06E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 325 P324 Position #7 6

2.47E+06 H-3 1.76 4.04E+06 2.33E+08 0.0173 0.1304 3.42E+09 0.0012 0.0089 3.25E+07 0.1244 0.9322 Co-60 0.06431 1.59E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0074 Ni-63 442 7.03E+07 3.93E+09 0.0179 5.78E+10 0.0012 5.50E+08 0.1278 Sr-90 0.021 4.82E+04 1.40E+06 0.0345 2.06E+07 0.0023 1.96E+05 0.2461 Cs-134 0.00014 3.37E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.30E+06 3.85E+07 0.0597 5.66E+08 0.0041 5.39E+06 0.4261 Eu-152 0.00599 1.48E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.02E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 326 P324 Position #8 7

2.62E+06 H-3 1.76 4.29E+06 2.33E+08 0.0184 0.1383 3.42E+09 0.0013 0.0094 3.25E+07 0.1319 0.9887 Co-60 0.06431 1.69E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0078 Ni-63 442 7.45E+07 3.93E+09 0.0190 5.78E+10 0.0013 5.50E+08 0.1355 Sr-90 0.021 5.12E+04 1.40E+06 0.0365 2.06E+07 0.0025 1.96E+05 0.2610 Cs-134 0.00014 3.57E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.44E+06 3.85E+07 0.0633 5.66E+08 0.0043 5.39E+06 0.4519 Eu-152 0.00599 1.57E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.14E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 327 P324 Position #9 8

2.81E+06 H-3 1.76 4.59E+06 2.33E+08 0.0197 0.1480 3.42E+09 0.0013 0.0101 3.25E+07 0.1411 1.0576 Co-60 0.06431 1.80E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0084 Ni-63 442 7.97E+07 3.93E+09 0.0203 5.78E+10 0.0014 5.50E+08 0.1450 Sr-90 0.021 5.47E+04 1.40E+06 0.0391 2.06E+07 0.0027 1.96E+05 0.2792 Cs-134 0.00014 3.82E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.61E+06 3.85E+07 0.0677 5.66E+08 0.0046 5.39E+06 0.4834 Eu-152 0.00599 1.68E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.29E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 328 P324 Position #10 9

2.55E+06 H-3 1.76 4.17E+06 2.33E+08 0.0179 0.1344 3.42E+09 0.0012 0.0091 3.25E+07 0.1282 0.9608 Co-60 0.06431 1.64E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0076 Ni-63 442 7.24E+07 3.93E+09 0.0184 5.78E+10 0.0013 5.50E+08 0.1317 Sr-90 0.021 4.97E+04 1.40E+06 0.0355 2.06E+07 0.0024 1.96E+05 0.2536 Cs-134 0.00014 3.47E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.37E+06 3.85E+07 0.0615 5.66E+08 0.0042 5.39E+06 0.4392 Eu-152 0.00599 1.53E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.08E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 329 P324 Position #11 10 2.43E+06 H-3 1.76 3.98E+06 2.33E+08 0.0171 0.1284 3.42E+09 0.0012 0.0087 3.25E+07 0.1224 0.9177 Co-60 0.06431 1.57E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0073 Ni-63 442 6.92E+07 3.93E+09 0.0176 5.78E+10 0.0012 5.50E+08 0.1258 Sr-90 0.021 4.75E+04 1.40E+06 0.0339 2.06E+07 0.0023 1.96E+05 0.2422 Cs-134 0.00014 3.32E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.26E+06 3.85E+07 0.0587 5.66E+08 0.0040 5.39E+06 0.4195 Eu-152 0.00599 1.46E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.99E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[96]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 330 P324 Position #12 11 2.50E+06 H-3 1.76 4.09E+06 2.33E+08 0.0175 0.1318 3.42E+09 0.0012 0.0090 3.25E+07 0.1257 0.9421 Co-60 0.06431 1.61E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0075 Ni-63 442 7.10E+07 3.93E+09 0.0181 5.78E+10 0.0012 5.50E+08 0.1292 Sr-90 0.021 4.87E+04 1.40E+06 0.0348 2.06E+07 0.0024 1.96E+05 0.2487 Cs-134 0.00014 3.41E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.32E+06 3.85E+07 0.0603 5.66E+08 0.0041 5.39E+06 0.4307 Eu-152 0.00599 1.50E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.04E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 331 P324 Position #13 12 2.47E+06 H-3 1.76 4.03E+06 2.33E+08 0.0173 0.1302 3.42E+09 0.0012 0.0089 3.25E+07 0.1241 0.9303 Co-60 0.06431 1.59E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0074 Ni-63 442 7.01E+07 3.93E+09 0.0178 5.78E+10 0.0012 5.50E+08 0.1275 Sr-90 0.021 4.81E+04 1.40E+06 0.0344 2.06E+07 0.0023 1.96E+05 0.2456 Cs-134 0.00014 3.36E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.29E+06 3.85E+07 0.0595 5.66E+08 0.0040 5.39E+06 0.4252 Eu-152 0.00599 1.48E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.02E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 332 P324 Position #14 13 2.50E+06 H-3 1.76 4.09E+06 2.33E+08 0.0176 0.1320 3.42E+09 0.0012 0.0090 3.25E+07 0.1258 0.9432 Co-60 0.06431 1.61E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0075 Ni-63 442 7.11E+07 3.93E+09 0.0181 5.78E+10 0.0012 5.50E+08 0.1293 Sr-90 0.021 4.88E+04 1.40E+06 0.0349 2.06E+07 0.0024 1.96E+05 0.2490 Cs-134 0.00014 3.41E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.32E+06 3.85E+07 0.0604 5.66E+08 0.0041 5.39E+06 0.4311 Eu-152 0.00599 1.50E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.05E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 333 P324 Position #15 14 2.53E+06 H-3 1.76 4.13E+06 2.33E+08 0.0177 0.1334 3.42E+09 0.0012 0.0091 3.25E+07 0.1272 0.9535 Co-60 0.06431 1.63E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0076 Ni-63 442 7.19E+07 3.93E+09 0.0183 5.78E+10 0.0012 5.50E+08 0.1307 Sr-90 0.021 4.93E+04 1.40E+06 0.0352 2.06E+07 0.0024 1.96E+05 0.2517 Cs-134 0.00014 3.45E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.35E+06 3.85E+07 0.0610 5.66E+08 0.0042 5.39E+06 0.4358 Eu-152 0.00599 1.52E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.07E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 334 P324 Position #16 15 2.58E+06 H-3 1.76 4.22E+06 2.33E+08 0.0181 0.1363 3.42E+09 0.0012 0.0093 3.25E+07 0.1299 0.9739 Co-60 0.06431 1.66E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0077 Ni-63 442 7.34E+07 3.93E+09 0.0187 5.78E+10 0.0013 5.50E+08 0.1335 Sr-90 0.021 5.04E+04 1.40E+06 0.0360 2.06E+07 0.0024 1.96E+05 0.2571 Cs-134 0.00014 3.52E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.40E+06 3.85E+07 0.0623 5.66E+08 0.0042 5.39E+06 0.4452 Eu-152 0.00599 1.55E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.11E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 335 P324 Position #17 16 2.97E+06 H-3 1.76 4.85E+06 2.33E+08 0.0208 0.1565 3.42E+09 0.0014 0.0106 3.25E+07 0.1492 1.1185 Co-60 0.06431 1.91E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0089 Ni-63 442 8.43E+07 3.93E+09 0.0215 5.78E+10 0.0015 5.50E+08 0.1533 Sr-90 0.021 5.79E+04 1.40E+06 0.0413 2.06E+07 0.0028 1.96E+05 0.2953 Cs-134 0.00014 4.04E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.76E+06 3.85E+07 0.0716 5.66E+08 0.0049 5.39E+06 0.5113 Eu-152 0.00599 1.78E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.43E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[97]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 336 P324 Position #18 17 3.14E+06 H-3 1.76 5.13E+06 2.33E+08 0.0220 0.1657 3.42E+09 0.0015 0.0113 3.25E+07 0.1580 1.1840 Co-60 0.06431 2.02E+05 1.54E+08 0.0013 2.26E+09 0.0001 2.15E+07 0.0094 Ni-63 442 8.93E+07 3.93E+09 0.0227 5.78E+10 0.0015 5.50E+08 0.1623 Sr-90 0.021 6.13E+04 1.40E+06 0.0438 2.06E+07 0.0030 1.96E+05 0.3126 Cs-134 0.00014 4.28E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.92E+06 3.85E+07 0.0758 5.66E+08 0.0052 5.39E+06 0.5412 Eu-152 0.00599 1.88E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.57E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 337 P324 Position #19 18 2.70E+06 H-3 1.76 4.41E+06 2.33E+08 0.0189 0.1425 3.42E+09 0.0013 0.0097 3.25E+07 0.1358 1.0181 Co-60 0.06431 1.74E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0081 Ni-63 442 7.68E+07 3.93E+09 0.0195 5.78E+10 0.0013 5.50E+08 0.1396 Sr-90 0.021 5.27E+04 1.40E+06 0.0376 2.06E+07 0.0026 1.96E+05 0.2688 Cs-134 0.00014 3.68E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.51E+06 3.85E+07 0.0652 5.66E+08 0.0044 5.39E+06 0.4654 Eu-152 0.00599 1.62E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.21E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 338 P324 Position #20 19 2.59E+06 H-3 1.76 4.23E+06 2.33E+08 0.0181 0.1364 3.42E+09 0.0012 0.0093 3.25E+07 0.1301 0.9749 Co-60 0.06431 1.66E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0077 Ni-63 442 7.35E+07 3.93E+09 0.0187 5.78E+10 0.0013 5.50E+08 0.1337 Sr-90 0.021 5.04E+04 1.40E+06 0.0360 2.06E+07 0.0024 1.96E+05 0.2574 Cs-134 0.00014 3.52E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.40E+06 3.85E+07 0.0624 5.66E+08 0.0042 5.39E+06 0.4456 Eu-152 0.00599 1.55E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.11E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 339 P324 Position #21 20 2.75E+06 H-3 1.76 4.49E+06 2.33E+08 0.0193 0.1448 3.42E+09 0.0013 0.0099 3.25E+07 0.1381 1.0351 Co-60 0.06431 1.77E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0082 Ni-63 442 7.80E+07 3.93E+09 0.0199 5.78E+10 0.0014 5.50E+08 0.1419 Sr-90 0.021 5.36E+04 1.40E+06 0.0383 2.06E+07 0.0026 1.96E+05 0.2732 Cs-134 0.00014 3.74E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.55E+06 3.85E+07 0.0662 5.66E+08 0.0045 5.39E+06 0.4732 Eu-152 0.00599 1.65E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.24E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 340 P324 Position #22 21 2.55E+06 H-3 1.76 4.16E+06 2.33E+08 0.0179 0.1343 3.42E+09 0.0012 0.0091 3.25E+07 0.1281 0.9598 Co-60 0.06431 1.64E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0076 Ni-63 442 7.24E+07 3.93E+09 0.0184 5.78E+10 0.0013 5.50E+08 0.1316 Sr-90 0.021 4.97E+04 1.40E+06 0.0355 2.06E+07 0.0024 1.96E+05 0.2534 Cs-134 0.00014 3.47E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.36E+06 3.85E+07 0.0614 5.66E+08 0.0042 5.39E+06 0.4387 Eu-152 0.00599 1.53E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.08E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 341 P324 Position #23 22 2.28E+06 H-3 1.76 3.73E+06 2.33E+08 0.0160 0.1204 3.42E+09 0.0011 0.0082 3.25E+07 0.1148 0.8603 Co-60 0.06431 1.47E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0068 Ni-63 442 6.49E+07 3.93E+09 0.0165 5.78E+10 0.0011 5.50E+08 0.1179 Sr-90 0.021 4.45E+04 1.40E+06 0.0318 2.06E+07 0.0022 1.96E+05 0.2271 Cs-134 0.00014 3.11E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.12E+06 3.85E+07 0.0551 5.66E+08 0.0037 5.39E+06 0.3932 Eu-152 0.00599 1.37E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.87E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[98]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 342 P324 Position #24 23 2.26E+06 H-3 1.76 3.69E+06 2.33E+08 0.0158 0.1190 3.42E+09 0.0011 0.0081 3.25E+07 0.1135 0.8506 Co-60 0.06431 1.45E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0067 Ni-63 442 6.41E+07 3.93E+09 0.0163 5.78E+10 0.0011 5.50E+08 0.1166 Sr-90 0.021 4.40E+04 1.40E+06 0.0314 2.06E+07 0.0021 1.96E+05 0.2245 Cs-134 0.00014 3.07E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.10E+06 3.85E+07 0.0544 5.66E+08 0.0037 5.39E+06 0.3888 Eu-152 0.00599 1.35E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.84E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 343 P324 Position #25 24 2.24E+06 H-3 1.76 3.67E+06 2.33E+08 0.0157 0.1183 3.42E+09 0.0011 0.0080 3.25E+07 0.1129 0.8458 Co-60 0.06431 1.44E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0067 Ni-63 442 6.38E+07 3.93E+09 0.0162 5.78E+10 0.0011 5.50E+08 0.1160 Sr-90 0.021 4.38E+04 1.40E+06 0.0313 2.06E+07 0.0021 1.96E+05 0.2233 Cs-134 0.00014 3.06E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.08E+06 3.85E+07 0.0541 5.66E+08 0.0037 5.39E+06 0.3866 Eu-152 0.00599 1.35E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.83E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 344 P324 Position #26 25 3.06E+06 H-3 1.76 5.00E+06 2.33E+08 0.0215 0.1615 3.42E+09 0.0015 0.0110 3.25E+07 0.1540 1.1541 Co-60 0.06431 1.97E+05 1.54E+08 0.0013 2.26E+09 0.0001 2.15E+07 0.0092 Ni-63 442 8.70E+07 3.93E+09 0.0221 5.78E+10 0.0015 5.50E+08 0.1582 Sr-90 0.021 5.97E+04 1.40E+06 0.0427 2.06E+07 0.0029 1.96E+05 0.3047 Cs-134 0.00014 4.17E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.84E+06 3.85E+07 0.0739 5.66E+08 0.0050 5.39E+06 0.5275 Eu-152 0.00599 1.84E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.50E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 345 P324 Position #27 26 3.85E+06 H-3 1.76 6.30E+06 2.33E+08 0.0270 0.2033 3.42E+09 0.0018 0.0138 3.25E+07 0.1939 1.4529 Co-60 0.06431 2.48E+05 1.54E+08 0.0016 2.26E+09 0.0001 2.15E+07 0.0115 Ni-63 442 1.10E+08 3.93E+09 0.0279 5.78E+10 0.0019 5.50E+08 0.1992 Sr-90 0.021 7.52E+04 1.40E+06 0.0537 2.06E+07 0.0036 1.96E+05 0.3835 Cs-134 0.00014 5.25E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.58E+06 3.85E+07 0.0930 5.66E+08 0.0063 5.39E+06 0.6641 Eu-152 0.00599 2.31E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.15E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 346 P324 Position #28 27 2.53E+06 H-3 1.76 4.13E+06 2.33E+08 0.0177 0.1333 3.42E+09 0.0012 0.0091 3.25E+07 0.1271 0.9529 Co-60 0.06431 1.63E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0076 Ni-63 442 7.18E+07 3.93E+09 0.0183 5.78E+10 0.0012 5.50E+08 0.1306 Sr-90 0.021 4.93E+04 1.40E+06 0.0352 2.06E+07 0.0024 1.96E+05 0.2515 Cs-134 0.00014 3.44E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.35E+06 3.85E+07 0.0610 5.66E+08 0.0041 5.39E+06 0.4356 Eu-152 0.00599 1.52E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.07E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 347 P324 Position #29 28 2.27E+06 H-3 1.76 3.71E+06 2.33E+08 0.0159 0.1196 3.42E+09 0.0011 0.0081 3.25E+07 0.1141 0.8550 Co-60 0.06431 1.46E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0068 Ni-63 442 6.45E+07 3.93E+09 0.0164 5.78E+10 0.0011 5.50E+08 0.1172 Sr-90 0.021 4.42E+04 1.40E+06 0.0316 2.06E+07 0.0021 1.96E+05 0.2257 Cs-134 0.00014 3.09E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.11E+06 3.85E+07 0.0547 5.66E+08 0.0037 5.39E+06 0.3908 Eu-152 0.00599 1.36E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.85E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[99]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 348 P324 Position #30 29 2.22E+06 H-3 1.76 3.63E+06 2.33E+08 0.0156 0.1171 3.42E+09 0.0011 0.0080 3.25E+07 0.1117 0.8368 Co-60 0.06431 1.43E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0066 Ni-63 442 6.31E+07 3.93E+09 0.0161 5.78E+10 0.0011 5.50E+08 0.1147 Sr-90 0.021 4.33E+04 1.40E+06 0.0309 2.06E+07 0.0021 1.96E+05 0.2209 Cs-134 0.00014 3.02E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.06E+06 3.85E+07 0.0536 5.66E+08 0.0036 5.39E+06 0.3825 Eu-152 0.00599 1.33E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.81E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 349 P324 Position #31 30 2.16E+06 H-3 1.76 3.53E+06 2.33E+08 0.0152 0.1140 3.42E+09 0.0010 0.0078 3.25E+07 0.1087 0.8146 Co-60 0.06431 1.39E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0065 Ni-63 442 6.14E+07 3.93E+09 0.0156 5.78E+10 0.0011 5.50E+08 0.1117 Sr-90 0.021 4.21E+04 1.40E+06 0.0301 2.06E+07 0.0020 1.96E+05 0.2150 Cs-134 0.00014 2.94E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.01E+06 3.85E+07 0.0521 5.66E+08 0.0035 5.39E+06 0.3723 Eu-152 0.00599 1.30E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.77E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 350 P324 Position #32 31 2.19E+06 H-3 1.76 3.59E+06 2.33E+08 0.0154 0.1158 3.42E+09 0.0010 0.0079 3.25E+07 0.1104 0.8274 Co-60 0.06431 1.41E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0066 Ni-63 442 6.24E+07 3.93E+09 0.0159 5.78E+10 0.0011 5.50E+08 0.1134 Sr-90 0.021 4.28E+04 1.40E+06 0.0306 2.06E+07 0.0021 1.96E+05 0.2184 Cs-134 0.00014 2.99E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.04E+06 3.85E+07 0.0529 5.66E+08 0.0036 5.39E+06 0.3782 Eu-152 0.00599 1.32E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.79E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 351 P324 Position #33 32 2.28E+06 H-3 1.76 3.73E+06 2.33E+08 0.0160 0.1203 3.42E+09 0.0011 0.0082 3.25E+07 0.1147 0.8598 Co-60 0.06431 1.47E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0068 Ni-63 442 6.48E+07 3.93E+09 0.0165 5.78E+10 0.0011 5.50E+08 0.1179 Sr-90 0.021 4.45E+04 1.40E+06 0.0318 2.06E+07 0.0022 1.96E+05 0.2270 Cs-134 0.00014 3.11E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.12E+06 3.85E+07 0.0550 5.66E+08 0.0037 5.39E+06 0.3930 Eu-152 0.00599 1.37E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.86E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 352 P324 Position #34 33 2.57E+06 H-3 1.76 4.21E+06 2.33E+08 0.0181 0.1357 3.42E+09 0.0012 0.0092 3.25E+07 0.1294 0.9699 Co-60 0.06431 1.65E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0077 Ni-63 442 7.31E+07 3.93E+09 0.0186 5.78E+10 0.0013 5.50E+08 0.1330 Sr-90 0.021 5.02E+04 1.40E+06 0.0358 2.06E+07 0.0024 1.96E+05 0.2560 Cs-134 0.00014 3.51E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.39E+06 3.85E+07 0.0621 5.66E+08 0.0042 5.39E+06 0.4434 Eu-152 0.00599 1.54E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.10E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 353 P324 Position #35 34 4.27E+06 H-3 1.76 6.98E+06 2.33E+08 0.0299 0.2251 3.42E+09 0.0020 0.0153 3.25E+07 0.2146 1.6086 Co-60 0.06431 2.74E+05 1.54E+08 0.0018 2.26E+09 0.0001 2.15E+07 0.0128 Ni-63 442 1.21E+08 3.93E+09 0.0309 5.78E+10 0.0021 5.50E+08 0.2205 Sr-90 0.021 8.32E+04 1.40E+06 0.0594 2.06E+07 0.0040 1.96E+05 0.4246 Cs-134 0.00014 5.81E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.96E+06 3.85E+07 0.1029 5.66E+08 0.0070 5.39E+06 0.7353 Eu-152 0.00599 2.56E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.49E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[100]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 354 P324 Position #36 35 4.92E+06 H-3 1.76 8.05E+06 2.33E+08 0.0345 0.2598 3.42E+09 0.0024 0.0177 3.25E+07 0.2477 1.8564 Co-60 0.06431 3.17E+05 1.54E+08 0.0021 2.26E+09 0.0001 2.15E+07 0.0147 Ni-63 442 1.40E+08 3.93E+09 0.0356 5.78E+10 0.0024 5.50E+08 0.2545 Sr-90 0.021 9.61E+04 1.40E+06 0.0686 2.06E+07 0.0047 1.96E+05 0.4901 Cs-134 0.00014 6.71E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0002 Cs-137 0.92875 4.57E+06 3.85E+07 0.1188 5.66E+08 0.0081 5.39E+06 0.8486 Eu-152 0.00599 2.95E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0006 Eu-154 0.00082 4.03E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 355 P324 Position #37 36 3.90E+06 H-3 1.76 6.37E+06 2.33E+08 0.0274 0.2057 3.42E+09 0.0019 0.0140 3.25E+07 0.1961 1.4700 Co-60 0.06431 2.51E+05 1.54E+08 0.0016 2.26E+09 0.0001 2.15E+07 0.0117 Ni-63 442 1.11E+08 3.93E+09 0.0282 5.78E+10 0.0019 5.50E+08 0.2015 Sr-90 0.021 7.61E+04 1.40E+06 0.0543 2.06E+07 0.0037 1.96E+05 0.3881 Cs-134 0.00014 5.31E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.62E+06 3.85E+07 0.0941 5.66E+08 0.0064 5.39E+06 0.6720 Eu-152 0.00599 2.34E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.19E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 356 P324 Position #38 37 2.86E+06 H-3 1.76 4.67E+06 2.33E+08 0.0200 0.1507 3.42E+09 0.0014 0.0102 3.25E+07 0.1437 1.0767 Co-60 0.06431 1.84E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0085 Ni-63 442 8.12E+07 3.93E+09 0.0207 5.78E+10 0.0014 5.50E+08 0.1476 Sr-90 0.021 5.57E+04 1.40E+06 0.0398 2.06E+07 0.0027 1.96E+05 0.2842 Cs-134 0.00014 3.89E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.65E+06 3.85E+07 0.0689 5.66E+08 0.0047 5.39E+06 0.4922 Eu-152 0.00599 1.71E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.33E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 357 P324 Position #39 38 2.53E+06 H-3 1.76 4.13E+06 2.33E+08 0.0177 0.1332 3.42E+09 0.0012 0.0091 3.25E+07 0.1270 0.9518 Co-60 0.06431 1.62E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0076 Ni-63 442 7.18E+07 3.93E+09 0.0183 5.78E+10 0.0012 5.50E+08 0.1305 Sr-90 0.021 4.92E+04 1.40E+06 0.0352 2.06E+07 0.0024 1.96E+05 0.2513 Cs-134 0.00014 3.44E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.35E+06 3.85E+07 0.0609 5.66E+08 0.0041 5.39E+06 0.4351 Eu-152 0.00599 1.51E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.06E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 358 P324 Position #40 39 2.30E+06 H-3 1.76 3.76E+06 2.33E+08 0.0162 0.1215 3.42E+09 0.0011 0.0083 3.25E+07 0.1158 0.8682 Co-60 0.06431 1.48E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0069 Ni-63 442 6.55E+07 3.93E+09 0.0167 5.78E+10 0.0011 5.50E+08 0.1190 Sr-90 0.021 4.49E+04 1.40E+06 0.0321 2.06E+07 0.0022 1.96E+05 0.2292 Cs-134 0.00014 3.14E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.14E+06 3.85E+07 0.0556 5.66E+08 0.0038 5.39E+06 0.3969 Eu-152 0.00599 1.38E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.88E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 359 P324 Position #41 40 2.26E+06 H-3 1.76 3.69E+06 2.33E+08 0.0159 0.1192 3.42E+09 0.0011 0.0081 3.25E+07 0.1137 0.8520 Co-60 0.06431 1.45E+05 1.54E+08 0.0009 2.26E+09 0.0001 2.15E+07 0.0068 Ni-63 442 6.42E+07 3.93E+09 0.0163 5.78E+10 0.0011 5.50E+08 0.1168 Sr-90 0.021 4.41E+04 1.40E+06 0.0315 2.06E+07 0.0021 1.96E+05 0.2249 Cs-134 0.00014 3.08E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.10E+06 3.85E+07 0.0545 5.66E+08 0.0037 5.39E+06 0.3895 Eu-152 0.00599 1.35E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.85E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[101]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 360 P324 Position #42 41 2.28E+06 H-3 1.76 3.72E+06 2.33E+08 0.0160 0.1201 3.42E+09 0.0011 0.0082 3.25E+07 0.1146 0.8586 Co-60 0.06431 1.46E+05 1.54E+08 0.0010 2.26E+09 0.0001 2.15E+07 0.0068 Ni-63 442 6.47E+07 3.93E+09 0.0165 5.78E+10 0.0011 5.50E+08 0.1177 Sr-90 0.021 4.44E+04 1.40E+06 0.0317 2.06E+07 0.0022 1.96E+05 0.2267 Cs-134 0.00014 3.10E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.12E+06 3.85E+07 0.0549 5.66E+08 0.0037 5.39E+06 0.3925 Eu-152 0.00599 1.37E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 1.86E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 361 P324 Position #43 42 2.57E+06 H-3 1.76 4.20E+06 2.33E+08 0.0180 0.1355 3.42E+09 0.0012 0.0092 3.25E+07 0.1292 0.9686 Co-60 0.06431 1.65E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0077 Ni-63 442 7.30E+07 3.93E+09 0.0186 5.78E+10 0.0013 5.50E+08 0.1328 Sr-90 0.021 5.01E+04 1.40E+06 0.0358 2.06E+07 0.0024 1.96E+05 0.2557 Cs-134 0.00014 3.50E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.39E+06 3.85E+07 0.0620 5.66E+08 0.0042 5.39E+06 0.4428 Eu-152 0.00599 1.54E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.10E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000 362 P324 Position #44 43 4.38E+06 H-3 1.76 7.17E+06 2.33E+08 0.0308 0.2313 3.42E+09 0.0021 0.0157 3.25E+07 0.2205 1.6529 Co-60 0.06431 2.82E+05 1.54E+08 0.0018 2.26E+09 0.0001 2.15E+07 0.0131 Ni-63 442 1.25E+08 3.93E+09 0.0317 5.78E+10 0.0022 5.50E+08 0.2266 Sr-90 0.021 8.55E+04 1.40E+06 0.0611 2.06E+07 0.0042 1.96E+05 0.4363 Cs-134 0.00014 5.97E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 4.07E+06 3.85E+07 0.1058 5.66E+08 0.0072 5.39E+06 0.7556 Eu-152 0.00599 2.63E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0005 Eu-154 0.00082 3.58E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 363 P324 Position #45 44 3.67E+06 H-3 1.76 6.00E+06 2.33E+08 0.0257 0.1935 3.42E+09 0.0018 0.0132 3.25E+07 0.1845 1.3829 Co-60 0.06431 2.36E+05 1.54E+08 0.0015 2.26E+09 0.0001 2.15E+07 0.0110 Ni-63 442 1.04E+08 3.93E+09 0.0265 5.78E+10 0.0018 5.50E+08 0.1896 Sr-90 0.021 7.16E+04 1.40E+06 0.0511 2.06E+07 0.0035 1.96E+05 0.3651 Cs-134 0.00014 5.00E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.41E+06 3.85E+07 0.0885 5.66E+08 0.0060 5.39E+06 0.6321 Eu-152 0.00599 2.20E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 3.00E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 364 P324 Position #46 45 2.71E+06 H-3 1.76 4.43E+06 2.33E+08 0.0190 0.1428 3.42E+09 0.0013 0.0097 3.25E+07 0.1362 1.0206 Co-60 0.06431 1.74E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0081 Ni-63 442 7.70E+07 3.93E+09 0.0196 5.78E+10 0.0013 5.50E+08 0.1399 Sr-90 0.021 5.28E+04 1.40E+06 0.0377 2.06E+07 0.0026 1.96E+05 0.2694 Cs-134 0.00014 3.69E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.51E+06 3.85E+07 0.0653 5.66E+08 0.0044 5.39E+06 0.4665 Eu-152 0.00599 1.62E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.21E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 365 P324 Position #47 46 2.65E+06 H-3 1.76 4.34E+06 2.33E+08 0.0186 0.1399 3.42E+09 0.0013 0.0095 3.25E+07 0.1334 0.9999 Co-60 0.06431 1.71E+05 1.54E+08 0.0011 2.26E+09 0.0001 2.15E+07 0.0079 Ni-63 442 7.54E+07 3.93E+09 0.0192 5.78E+10 0.0013 5.50E+08 0.1371 Sr-90 0.021 5.17E+04 1.40E+06 0.0370 2.06E+07 0.0025 1.96E+05 0.2639 Cs-134 0.00014 3.61E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.46E+06 3.85E+07 0.0640 5.66E+08 0.0044 5.39E+06 0.4571 Eu-152 0.00599 1.59E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.17E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[102]

No.

Sample ID Feet into Pipe Gamma Result ROC Gamma Mixture/

HTD Ratio Activity per ROC CTMT OpDCGLPN Nuclide SOF Total SOF CTMT BcDCGLPN Nuclide SOF Total SOF CTMT OpDCGLB Nuclide SOF Total SOF (pCi/m2)

(pCi/m2)

(pCi/m2)

OpSOFPN OpSOFPN (pCi/m2)

BcSOFPN BcSOFPN (pCi/m2)

OpSOFB OpSOFB 366 P324 Position #48 47 2.90E+06 H-3 1.76 4.74E+06 2.33E+08 0.0203 0.1528 3.42E+09 0.0014 0.0104 3.25E+07 0.1457 1.0924 Co-60 0.06431 1.86E+05 1.54E+08 0.0012 2.26E+09 0.0001 2.15E+07 0.0087 Ni-63 442 8.24E+07 3.93E+09 0.0210 5.78E+10 0.0014 5.50E+08 0.1498 Sr-90 0.021 5.65E+04 1.40E+06 0.0404 2.06E+07 0.0027 1.96E+05 0.2884 Cs-134 0.00014 3.95E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 2.69E+06 3.85E+07 0.0699 5.66E+08 0.0048 5.39E+06 0.4993 Eu-152 0.00599 1.74E+04 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0003 Eu-154 0.00082 2.37E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 367 P324 Position #49 48 3.66E+06 H-3 1.76 5.99E+06 2.33E+08 0.0257 0.1932 3.42E+09 0.0018 0.0131 3.25E+07 0.1843 1.3810 Co-60 0.06431 2.36E+05 1.54E+08 0.0015 2.26E+09 0.0001 2.15E+07 0.0110 Ni-63 442 1.04E+08 3.93E+09 0.0265 5.78E+10 0.0018 5.50E+08 0.1893 Sr-90 0.021 7.15E+04 1.40E+06 0.0510 2.06E+07 0.0035 1.96E+05 0.3646 Cs-134 0.00014 4.99E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.40E+06 3.85E+07 0.0884 5.66E+08 0.0060 5.39E+06 0.6313 Eu-152 0.00599 2.20E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.99E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 368 P324 Position #50 49 3.49E+06 H-3 1.76 5.70E+06 2.33E+08 0.0245 0.1839 3.42E+09 0.0017 0.0125 3.25E+07 0.1754 1.3144 Co-60 0.06431 2.24E+05 1.54E+08 0.0015 2.26E+09 0.0001 2.15E+07 0.0104 Ni-63 442 9.91E+07 3.93E+09 0.0252 5.78E+10 0.0017 5.50E+08 0.1802 Sr-90 0.021 6.80E+04 1.40E+06 0.0486 2.06E+07 0.0033 1.96E+05 0.3470 Cs-134 0.00014 4.75E+02 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0001 Cs-137 0.92875 3.24E+06 3.85E+07 0.0841 5.66E+08 0.0057 5.39E+06 0.6008 Eu-152 0.00599 2.09E+04 3.58E+08 0.0001 5.26E+09 0.0000 5.00E+07 0.0004 Eu-154 0.00082 2.85E+03 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0001 369 P220 By Direct Scan N/A 6.35E+04 H-3 1.76 1.04E+05 2.33E+08 0.0004 0.0033 3.42E+09 0.0000 0.0002 3.25E+07 0.0032 0.0239 Co-60 0.06431 4.08E+03 1.54E+08 0.0000 2.26E+09 0.0000 2.15E+07 0.0002 Ni-63 442 1.80E+06 3.93E+09 0.0005 5.78E+10 0.0000 5.50E+08 0.0033 Sr-90 0.021 1.24E+03 1.40E+06 0.0009 2.06E+07 0.0001 1.96E+05 0.0063 Cs-134 0.00014 8.65E+00 2.94E+07 0.0000 4.32E+08 0.0000 4.12E+06 0.0000 Cs-137 0.92875 5.90E+04 3.85E+07 0.0015 5.66E+08 0.0001 5.39E+06 0.0109 Eu-152 0.00599 3.81E+02 3.58E+08 0.0000 5.26E+09 0.0000 5.00E+07 0.0000 Eu-154 0.00082 5.19E+01 3.11E+08 0.0000 4.58E+09 0.0000 4.36E+07 0.0000

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[103]

ROC Concentrations per Measurement (Unit 2 Containment)

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P201 Position #1 2.12E+07 8.35E+05 3.69E+08 2.53E+05 1.77E+03 1.21E+07 7.78E+04 1.06E+04 0.6849 P201 Position #2 2.93E+06 1.15E+05 5.10E+07 3.50E+04 2.45E+02 1.67E+06 1.08E+04 1.47E+03 0.0947 P201 Position #3 1.87E+06 7.36E+04 3.25E+07 2.23E+04 1.56E+02 1.06E+06 6.86E+03 9.35E+02 0.0603 P201 Position #4 1.87E+06 7.34E+04 3.24E+07 2.23E+04 1.55E+02 1.06E+06 6.84E+03 9.33E+02 0.0602 P250 Position #1 1.64E+06 6.45E+04 2.85E+07 1.96E+04 1.37E+02 9.32E+05 6.01E+03 8.20E+02 0.0529 P250 Position #2 1.72E+06 6.79E+04 3.00E+07 2.06E+04 1.44E+02 9.80E+05 6.33E+03 8.63E+02 0.0557 P250 Position #3 1.85E+06 7.28E+04 3.22E+07 2.21E+04 1.54E+02 1.05E+06 6.78E+03 9.25E+02 0.0597 P250 Position #4 2.13E+06 8.36E+04 3.70E+07 2.54E+04 1.77E+02 1.21E+06 7.79E+03 1.06E+03 0.0686 P250 Position #5 4.06E+06 1.60E+05 7.06E+07 4.84E+04 3.38E+02 2.31E+06 1.49E+04 2.03E+03 0.1310 P287 Position #1 1.24E+06 4.89E+04 2.16E+07 1.48E+04 1.04E+02 7.07E+05 4.56E+03 6.22E+02 0.0401 P287 Position #2 1.55E+06 6.10E+04 2.69E+07 1.85E+04 1.29E+02 8.80E+05 5.68E+03 7.75E+02 0.0500 P287 Position #3 1.77E+06 6.96E+04 3.08E+07 2.11E+04 1.47E+02 1.00E+06 6.49E+03 8.85E+02 0.0571 P287 Position #4 2.16E+06 8.48E+04 3.75E+07 2.57E+04 1.80E+02 1.22E+06 7.91E+03 1.08E+03 0.0696 P287 Position #5 5.72E+06 2.25E+05 9.95E+07 6.83E+04 4.77E+02 3.25E+06 2.10E+04 2.86E+03 0.1847 P203 Position #1 2.79E+06 1.10E+05 4.86E+07 3.33E+04 2.33E+02 1.59E+06 1.02E+04 1.40E+03 0.0902 P203 Position #2 1.63E+06 6.40E+04 2.83E+07 1.94E+04 1.36E+02 9.24E+05 5.96E+03 8.13E+02 0.0525 P203 Position #3 1.45E+06 5.69E+04 2.52E+07 1.73E+04 1.21E+02 8.22E+05 5.31E+03 7.24E+02 0.0467 P203 Position #4 1.28E+06 5.03E+04 2.22E+07 1.53E+04 1.07E+02 7.27E+05 4.69E+03 6.40E+02 0.0413 P203 Position #5 3.16E+06 1.24E+05 5.50E+07 3.78E+04 2.64E+02 1.80E+06 1.16E+04 1.58E+03 0.1021 P264 Position #1 1.82E+06 7.16E+04 3.17E+07 2.17E+04 1.52E+02 1.03E+06 6.68E+03 9.11E+02 0.0588 P264 Position #2 1.78E+06 7.02E+04 3.10E+07 2.13E+04 1.49E+02 1.01E+06 6.54E+03 8.92E+02 0.0576 P264 Position #3 1.65E+06 6.49E+04 2.87E+07 1.97E+04 1.38E+02 9.38E+05 6.05E+03 8.25E+02 0.0532 P264 Position #4 1.70E+06 6.67E+04 2.95E+07 2.02E+04 1.41E+02 9.64E+05 6.22E+03 8.48E+02 0.0547 P264 Position #5 5.13E+06 2.02E+05 8.93E+07 6.12E+04 4.28E+02 2.92E+06 1.88E+04 2.57E+03 0.1656 P267 By Direct Scan 1.18E+05 4.66E+03 2.06E+06 1.41E+03 9.87E+00 6.73E+04 4.34E+02 5.92E+01 0.0038 P273 By Direct Scan 7.37E+05 2.90E+04 1.28E+07 8.80E+03 6.15E+01 4.19E+05 2.70E+03 3.69E+02 0.0238 P218 By Direct Scan 4.98E+05 1.96E+04 8.67E+06 5.95E+03 4.15E+01 2.83E+05 1.83E+03 2.49E+02 0.0161

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[104]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P254 Position #1 3.71E+06 1.46E+05 6.45E+07 4.43E+04 3.09E+02 2.11E+06 1.36E+04 1.86E+03 0.1197 P254 Position #2 1.40E+06 5.50E+04 2.43E+07 1.67E+04 1.17E+02 7.95E+05 5.13E+03 7.00E+02 0.0451 P254 Position #3 1.29E+06 5.08E+04 2.24E+07 1.54E+04 1.08E+02 7.33E+05 4.73E+03 6.45E+02 0.0416 P254 Position #4 1.34E+06 5.27E+04 2.33E+07 1.60E+04 1.12E+02 7.60E+05 4.91E+03 6.69E+02 0.0432 P217 By Direct Scan 9.31E+04 3.66E+03 1.62E+06 1.11E+03 7.76E+00 5.29E+04 3.41E+02 4.65E+01 0.0030 P221 By Direct Scan 7.20E+04 2.83E+03 1.25E+06 8.59E+02 6.00E+00 4.09E+04 2.64E+02 3.60E+01 0.0023 P290 By Direct Scan 9.18E+04 3.61E+03 1.60E+06 1.10E+03 7.65E+00 5.22E+04 3.37E+02 4.59E+01 0.0030 P305 By Direct Scan 9.80E+04 3.86E+03 1.70E+06 1.17E+03 8.17E+00 5.57E+04 3.59E+02 4.90E+01 0.0032 P292 By Direct Scan 8.02E+04 3.15E+03 1.39E+06 9.57E+02 6.68E+00 4.56E+04 2.94E+02 4.01E+01 0.0026 P209 By Direct Scan 1.12E+05 4.42E+03 1.95E+06 1.34E+03 9.37E+00 6.38E+04 4.12E+02 5.62E+01 0.0036 P205 By Direct Scan 1.68E+05 6.61E+03 2.92E+06 2.01E+03 1.40E+01 9.55E+04 6.16E+02 8.40E+01 0.0054 P206 By Direct Scan 1.30E+05 5.11E+03 2.26E+06 1.55E+03 1.08E+01 7.38E+04 4.76E+02 6.49E+01 0.0042 P327 By Direct Scan 9.18E+04 3.61E+03 1.60E+06 1.10E+03 7.65E+00 5.22E+04 3.37E+02 4.59E+01 0.0030 P211 By Direct Scan 1.05E+05 4.12E+03 1.82E+06 1.25E+03 8.73E+00 5.95E+04 3.84E+02 5.24E+01 0.0034 P315 By Direct Scan 5.65E+04 2.22E+03 9.82E+05 6.74E+02 4.71E+00 3.21E+04 2.07E+02 2.82E+01 0.0018 P207 By Direct Scan 4.10E+04 1.61E+03 7.12E+05 4.89E+02 3.41E+00 2.33E+04 1.50E+02 2.05E+01 0.0013 P296 By Direct Scan 5.55E+04 2.18E+03 9.65E+05 6.62E+02 4.63E+00 3.15E+04 2.04E+02 2.78E+01 0.0018 P286 Position #1 1.52E+07 5.97E+05 2.64E+08 1.81E+05 1.26E+03 8.62E+06 5.56E+04 7.58E+03 0.4894 P286 Position #2 3.00E+06 1.18E+05 5.22E+07 3.58E+04 2.50E+02 1.71E+06 1.10E+04 1.50E+03 0.0969 P286 Position #3 2.26E+06 8.89E+04 3.93E+07 2.69E+04 1.88E+02 1.28E+06 8.28E+03 1.13E+03 0.0729 P286 Position #4 2.07E+06 8.14E+04 3.60E+07 2.47E+04 1.72E+02 1.17E+06 7.58E+03 1.03E+03 0.0667 P289 Position #1 6.05E+06 2.38E+05 1.05E+08 7.21E+04 5.04E+02 3.43E+06 2.22E+04 3.02E+03 0.1951 P289 Position #2 2.06E+06 8.10E+04 3.58E+07 2.46E+04 1.72E+02 1.17E+06 7.55E+03 1.03E+03 0.0664 P289 Position #3 1.76E+06 6.93E+04 3.06E+07 2.10E+04 1.47E+02 1.00E+06 6.46E+03 8.81E+02 0.0569 P289 Position #4 2.17E+06 8.53E+04 3.77E+07 2.59E+04 1.81E+02 1.23E+06 7.95E+03 1.08E+03 0.0699 P288 Position #1 1.01E+07 3.98E+05 1.76E+08 1.21E+05 8.43E+02 5.75E+06 3.71E+04 5.06E+03 0.3264 P288 Position #2 2.14E+06 8.43E+04 3.72E+07 2.56E+04 1.79E+02 1.22E+06 7.86E+03 1.07E+03 0.0691 P288 Position #3 1.61E+06 6.32E+04 2.79E+07 1.92E+04 1.34E+02 9.13E+05 5.89E+03 8.04E+02 0.0519

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[105]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P288 Position #4 1.86E+06 7.32E+04 3.24E+07 2.22E+04 1.55E+02 1.06E+06 6.83E+03 9.31E+02 0.0601 P219 Position #1 7.12E+06 2.80E+05 1.24E+08 8.49E+04 5.93E+02 4.04E+06 2.61E+04 3.56E+03 0.2296 P219 Position #2 2.33E+06 9.15E+04 4.04E+07 2.78E+04 1.94E+02 1.32E+06 8.53E+03 1.16E+03 0.0751 P219 Position #3 2.21E+06 8.68E+04 3.84E+07 2.63E+04 1.84E+02 1.25E+06 8.09E+03 1.10E+03 0.0712 P219 Position #4 2.65E+06 1.04E+05 4.61E+07 3.17E+04 2.21E+02 1.51E+06 9.73E+03 1.33E+03 0.0856 P223 Position #1 9.60E+06 3.78E+05 1.67E+08 1.15E+05 8.00E+02 5.46E+06 3.52E+04 4.80E+03 0.3098 P223 Position #2 2.28E+06 8.97E+04 3.96E+07 2.72E+04 1.90E+02 1.30E+06 8.36E+03 1.14E+03 0.0736 P223 Position #3 1.96E+06 7.70E+04 3.41E+07 2.34E+04 1.63E+02 1.11E+06 7.18E+03 9.79E+02 0.0632 P223 Position #4 2.24E+06 8.82E+04 3.90E+07 2.67E+04 1.87E+02 1.27E+06 8.22E+03 1.12E+03 0.0723 P281 Position #1 1.34E+07 5.25E+05 2.32E+08 1.59E+05 1.11E+03 7.59E+06 4.90E+04 6.68E+03 0.4309 P281 Position #2 1.86E+06 7.31E+04 3.23E+07 2.22E+04 1.55E+02 1.06E+06 6.81E+03 9.29E+02 0.0599 P281 Position #3 1.27E+06 5.01E+04 2.22E+07 1.52E+04 1.06E+02 7.24E+05 4.67E+03 6.37E+02 0.0411 P281 Position #4 1.30E+06 5.12E+04 2.27E+07 1.55E+04 1.09E+02 7.40E+05 4.78E+03 6.51E+02 0.0420 P281 Position #5 1.25E+06 4.93E+04 2.18E+07 1.50E+04 1.04E+02 7.12E+05 4.60E+03 6.27E+02 0.0404 P243 Position #1 1.78E+07 6.98E+05 3.09E+08 2.12E+05 1.48E+03 1.01E+07 6.51E+04 8.88E+03 0.5728 P243 Position #2 2.07E+06 8.15E+04 3.60E+07 2.47E+04 1.73E+02 1.18E+06 7.60E+03 1.04E+03 0.0668 P243 Position #3 1.48E+06 5.80E+04 2.57E+07 1.76E+04 1.23E+02 8.38E+05 5.41E+03 7.38E+02 0.0476 P243 Position #4 1.41E+06 5.54E+04 2.45E+07 1.68E+04 1.17E+02 8.01E+05 5.17E+03 7.05E+02 0.0455 P243 Position #5 1.40E+06 5.51E+04 2.44E+07 1.67E+04 1.17E+02 7.96E+05 5.14E+03 7.01E+02 0.0452 P303 Position #1 2.07E+07 8.15E+05 3.60E+08 2.47E+05 1.73E+03 1.18E+07 7.60E+04 1.04E+04 0.6683 P303 Position #2 6.82E+06 2.68E+05 1.19E+08 8.14E+04 5.69E+02 3.88E+06 2.50E+04 3.41E+03 0.2201 P303 Position #3 9.00E+06 3.54E+05 1.56E+08 1.07E+05 7.50E+02 5.11E+06 3.30E+04 4.50E+03 0.2904 P303 Position #4 8.10E+06 3.18E+05 1.41E+08 9.66E+04 6.75E+02 4.60E+06 2.97E+04 4.05E+03 0.2612 P303 Position #5 6.82E+06 2.68E+05 1.19E+08 8.14E+04 5.69E+02 3.88E+06 2.50E+04 3.41E+03 0.2201 P303 Position #6 9.37E+06 3.69E+05 1.63E+08 1.12E+05 7.81E+02 5.32E+06 3.44E+04 4.69E+03 0.3023 P256 Position #1 1.24E+07 4.88E+05 2.16E+08 1.48E+05 1.03E+03 7.05E+06 4.55E+04 6.21E+03 0.4004 P256 Position #2 1.47E+06 5.79E+04 2.56E+07 1.76E+04 1.23E+02 8.36E+05 5.39E+03 7.36E+02 0.0475

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[106]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P256 Position #3 1.18E+06 4.64E+04 2.05E+07 1.41E+04 9.83E+01 6.70E+05 4.33E+03 5.90E+02 0.0381 P256 Position #4 1.10E+06 4.33E+04 1.91E+07 1.31E+04 9.18E+01 6.26E+05 4.04E+03 5.51E+02 0.0355 P256 Position #5 1.21E+06 4.75E+04 2.10E+07 1.44E+04 1.01E+02 6.86E+05 4.43E+03 6.04E+02 0.0390 P204 Position #1 1.22E+07 4.79E+05 2.11E+08 1.45E+05 1.01E+03 6.91E+06 4.46E+04 6.08E+03 0.3925 P204 Position #2 1.84E+06 7.23E+04 3.19E+07 2.19E+04 1.53E+02 1.04E+06 6.74E+03 9.19E+02 0.0593 P204 Position #3 1.56E+06 6.14E+04 2.72E+07 1.86E+04 1.30E+02 8.87E+05 5.73E+03 7.81E+02 0.0504 P204 Position #4 1.68E+06 6.63E+04 2.93E+07 2.01E+04 1.40E+02 9.57E+05 6.18E+03 8.43E+02 0.0544 P204 Position #5 1.44E+06 5.67E+04 2.51E+07 1.72E+04 1.20E+02 8.20E+05 5.29E+03 7.21E+02 0.0465 P242 Position #1 9.91E+06 3.90E+05 1.72E+08 1.18E+05 8.26E+02 5.63E+06 3.63E+04 4.95E+03 0.3197 P242 Position #2 1.81E+06 7.13E+04 3.15E+07 2.16E+04 1.51E+02 1.03E+06 6.65E+03 9.06E+02 0.0585 P242 Position #3 1.52E+06 5.98E+04 2.64E+07 1.81E+04 1.27E+02 8.64E+05 5.58E+03 7.61E+02 0.0491 P242 Position #4 1.59E+06 6.27E+04 2.77E+07 1.90E+04 1.33E+02 9.06E+05 5.85E+03 7.98E+02 0.0515 P242 Position #5 1.55E+06 6.10E+04 2.70E+07 1.85E+04 1.29E+02 8.81E+05 5.69E+03 7.76E+02 0.0501 P266 By Direct Scan 2.95E+05 1.16E+04 5.14E+06 3.52E+03 2.46E+01 1.68E+05 1.08E+03 1.48E+02 0.0095 P269 By Direct Scan 6.29E+04 2.48E+03 1.09E+06 7.51E+02 5.24E+00 3.58E+04 2.31E+02 3.15E+01 0.0020 P274 By Direct Scan 6.29E+04 2.48E+03 1.09E+06 7.51E+02 5.24E+00 3.58E+04 2.31E+02 3.15E+01 0.0020 P208 By Direct Scan 7.24E+04 2.85E+03 1.26E+06 8.64E+02 6.03E+00 4.11E+04 2.65E+02 3.62E+01 0.0023 P318 By Direct Scan 8.95E+04 3.52E+03 1.56E+06 1.07E+03 7.46E+00 5.08E+04 3.28E+02 4.47E+01 0.0029 P317 By Direct Scan 8.09E+04 3.18E+03 1.41E+06 9.66E+02 6.74E+00 4.60E+04 2.97E+02 4.05E+01 0.0026 P212 By Direct Scan 9.35E+04 3.68E+03 1.63E+06 1.12E+03 7.79E+00 5.31E+04 3.43E+02 4.67E+01 0.0030 P298 By Direct Scan 6.95E+04 2.74E+03 1.21E+06 8.30E+02 5.79E+00 3.95E+04 2.55E+02 3.48E+01 0.0022 P313 By Direct Scan 6.55E+04 2.58E+03 1.14E+06 7.82E+02 5.46E+00 3.72E+04 2.40E+02 3.28E+01 0.0021 P297 By Direct Scan 6.55E+04 2.58E+03 1.14E+06 7.82E+02 5.46E+00 3.72E+04 2.40E+02 3.28E+01 0.0021 P328 By Direct Scan 7.24E+04 2.85E+03 1.26E+06 8.64E+02 6.03E+00 4.11E+04 2.65E+02 3.62E+01 0.0023 P316 By Direct Scan 1.11E+05 4.35E+03 1.92E+06 1.32E+03 9.21E+00 6.28E+04 4.05E+02 5.53E+01 0.0036 P294 By Direct Scan 6.10E+04 2.40E+03 1.06E+06 7.28E+02 5.08E+00 3.46E+04 2.24E+02 3.05E+01 0.0020 P293 By Direct Scan 8.38E+04 3.30E+03 1.46E+06 1.00E+03 6.98E+00 4.76E+04 3.07E+02 4.19E+01 0.0027

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[107]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P210 By Direct Scan 2.02E+05 7.96E+03 3.52E+06 2.41E+03 1.69E+01 1.15E+05 7.42E+02 1.01E+02 0.0065 P312 By Direct Scan 8.83E+04 3.48E+03 1.54E+06 1.05E+03 7.36E+00 5.02E+04 3.24E+02 4.42E+01 0.0029 P295 By Direct Scan 8.66E+04 3.41E+03 1.51E+06 1.03E+03 7.22E+00 4.92E+04 3.18E+02 4.33E+01 0.0028 P291 By Direct Scan 1.40E+05 5.52E+03 2.44E+06 1.67E+03 1.17E+01 7.97E+04 5.14E+02 7.01E+01 0.0045 P270 By Direct Scan 4.30E+05 1.69E+04 7.48E+06 5.13E+03 3.59E+01 2.44E+05 1.58E+03 2.15E+02 0.0139 P268 By Direct Scan 3.20E+05 1.26E+04 5.56E+06 3.81E+03 2.66E+01 1.82E+05 1.17E+03 1.60E+02 0.0103 P222 By Direct Scan 9.92E+04 3.90E+03 1.72E+06 1.18E+03 8.26E+00 5.63E+04 3.64E+02 4.96E+01 0.0032 P304 By Direct Scan 3.43E+05 1.35E+04 5.97E+06 4.09E+03 2.86E+01 1.95E+05 1.26E+03 1.72E+02 0.0111 P237 Position #1 1.20E+07 4.73E+05 2.09E+08 1.43E+05 1.00E+03 6.83E+06 4.41E+04 6.01E+03 0.3878 P237 Position #2 5.56E+06 2.19E+05 9.67E+07 6.63E+04 4.63E+02 3.16E+06 2.04E+04 2.78E+03 0.1794 P237 Position #3 4.12E+06 1.62E+05 7.17E+07 4.92E+04 3.43E+02 2.34E+06 1.51E+04 2.06E+03 0.1330 P237 Position #4 4.01E+06 1.58E+05 6.97E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.1294 P237 Position #5 4.03E+06 1.59E+05 7.01E+07 4.81E+04 3.36E+02 2.29E+06 1.48E+04 2.02E+03 0.1300 P237 Position #6 3.90E+06 1.53E+05 6.78E+07 4.65E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.1258 P237 Position #7 3.81E+06 1.50E+05 6.62E+07 4.54E+04 3.17E+02 2.16E+06 1.40E+04 1.90E+03 0.1228 P237 Position #8 3.73E+06 1.47E+05 6.49E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.87E+03 0.1205 P237 Position #9 3.90E+06 1.53E+05 6.78E+07 4.66E+04 3.25E+02 2.22E+06 1.43E+04 1.95E+03 0.1259 P237 Position #10 3.76E+06 1.48E+05 6.54E+07 4.49E+04 3.14E+02 2.14E+06 1.38E+04 1.88E+03 0.1214 P237 Position #11 3.72E+06 1.47E+05 6.48E+07 4.44E+04 3.10E+02 2.12E+06 1.37E+04 1.86E+03 0.1202 P237 Position #12 3.85E+06 1.52E+05 6.70E+07 4.60E+04 3.21E+02 2.19E+06 1.41E+04 1.93E+03 0.1243 P237 Position #13 3.86E+06 1.52E+05 6.71E+07 4.61E+04 3.22E+02 2.19E+06 1.42E+04 1.93E+03 0.1246 P237 Position #14 3.77E+06 1.48E+05 6.56E+07 4.50E+04 3.14E+02 2.14E+06 1.38E+04 1.89E+03 0.1217 P237 Position #15 3.92E+06 1.54E+05 6.81E+07 4.67E+04 3.26E+02 2.23E+06 1.44E+04 1.96E+03 0.1264 P237 Position #16 3.75E+06 1.47E+05 6.52E+07 4.47E+04 3.12E+02 2.13E+06 1.37E+04 1.87E+03 0.1209 P237 Position #17 3.84E+06 1.51E+05 6.68E+07 4.58E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.1239 P237 Position #18 4.05E+06 1.59E+05 7.04E+07 4.83E+04 3.38E+02 2.30E+06 1.49E+04 2.03E+03 0.1307 P237 Position #19 3.93E+06 1.55E+05 6.84E+07 4.69E+04 3.28E+02 2.23E+06 1.44E+04 1.97E+03 0.1269

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[108]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P237 Position #20 3.65E+06 1.43E+05 6.34E+07 4.35E+04 3.04E+02 2.07E+06 1.34E+04 1.82E+03 0.1177 P237 Position #21 3.33E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.1073 P237 Position #22 3.35E+06 1.32E+05 5.82E+07 4.00E+04 2.79E+02 1.90E+06 1.23E+04 1.67E+03 0.1081 P237 Position #23 3.30E+06 1.30E+05 5.73E+07 3.93E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.1064 P237 Position #24 3.19E+06 1.25E+05 5.54E+07 3.80E+04 2.66E+02 1.81E+06 1.17E+04 1.59E+03 0.1029 P237 Position #25 3.30E+06 1.30E+05 5.75E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.1066 P237 Position #26 3.21E+06 1.26E+05 5.58E+07 3.83E+04 2.68E+02 1.82E+06 1.18E+04 1.61E+03 0.1036 P237 Position #27 3.30E+06 1.30E+05 5.73E+07 3.93E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.1064 P237 Position #28 3.31E+06 1.30E+05 5.75E+07 3.95E+04 2.76E+02 1.88E+06 1.21E+04 1.66E+03 0.1068 P237 Position #29 3.32E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.1072 P237 Position #30 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.1046 P237 Position #31 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.1046 P237 Position #32 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.1052 P237 Position #33 3.23E+06 1.27E+05 5.61E+07 3.85E+04 2.69E+02 1.83E+06 1.18E+04 1.61E+03 0.1041 P237 Position #34 3.22E+06 1.27E+05 5.60E+07 3.84E+04 2.68E+02 1.83E+06 1.18E+04 1.61E+03 0.1039 P237 Position #35 3.24E+06 1.27E+05 5.63E+07 3.86E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.1044 P237 Position #36 3.27E+06 1.29E+05 5.69E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.1057 P237 Position #37 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.1051 P237 Position #38 3.24E+06 1.27E+05 5.63E+07 3.86E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.1045 P237 Position #39 3.33E+06 1.31E+05 5.79E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.1074 P237 Position #40 3.22E+06 1.27E+05 5.60E+07 3.84E+04 2.68E+02 1.83E+06 1.18E+04 1.61E+03 0.1039 P237 Position #41 3.28E+06 1.29E+05 5.71E+07 3.92E+04 2.74E+02 1.86E+06 1.20E+04 1.64E+03 0.1059 P237 Position #42 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.1053 P237 Position #43 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.1058 P237 Position #44 3.25E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.1047 P237 Position #45 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.81E+02 1.92E+06 1.24E+04 1.69E+03 0.1089 P237 Position #46 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.1052

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[109]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P237 Position #47 3.33E+06 1.31E+05 5.79E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.1074 P237 Position #48 3.34E+06 1.31E+05 5.81E+07 3.99E+04 2.78E+02 1.90E+06 1.22E+04 1.67E+03 0.1078 P237 Position #49 3.23E+06 1.27E+05 5.62E+07 3.85E+04 2.69E+02 1.84E+06 1.18E+04 1.62E+03 0.1042 P237 Position #50 3.27E+06 1.29E+05 5.69E+07 3.90E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.1055 P236 Position #1 1.04E+07 4.10E+05 1.81E+08 1.24E+05 8.69E+02 5.93E+06 3.83E+04 5.22E+03 0.3366 P236 Position #2 5.58E+06 2.20E+05 9.71E+07 6.66E+04 4.65E+02 3.17E+06 2.05E+04 2.79E+03 0.1801 P236 Position #3 4.00E+06 1.57E+05 6.96E+07 4.78E+04 3.34E+02 2.27E+06 1.47E+04 2.00E+03 0.1292 P236 Position #4 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.1279 P236 Position #5 3.93E+06 1.55E+05 6.84E+07 4.69E+04 3.28E+02 2.24E+06 1.44E+04 1.97E+03 0.1269 P236 Position #6 3.82E+06 1.50E+05 6.65E+07 4.56E+04 3.19E+02 2.17E+06 1.40E+04 1.91E+03 0.1234 P236 Position #7 3.65E+06 1.44E+05 6.35E+07 4.36E+04 3.04E+02 2.08E+06 1.34E+04 1.83E+03 0.1179 P236 Position #8 3.63E+06 1.43E+05 6.32E+07 4.34E+04 3.03E+02 2.06E+06 1.33E+04 1.82E+03 0.1173 P236 Position #9 3.58E+06 1.41E+05 6.22E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.1155 P236 Position #10 3.62E+06 1.43E+05 6.30E+07 4.32E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.1169 P236 Position #11 3.51E+06 1.38E+05 6.10E+07 4.19E+04 2.92E+02 1.99E+06 1.29E+04 1.75E+03 0.1132 P236 Position #12 3.59E+06 1.41E+05 6.24E+07 4.28E+04 2.99E+02 2.04E+06 1.32E+04 1.80E+03 0.1158 P236 Position #13 3.62E+06 1.43E+05 6.30E+07 4.32E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.1169 P236 Position #14 3.56E+06 1.40E+05 6.19E+07 4.25E+04 2.97E+02 2.02E+06 1.30E+04 1.78E+03 0.1148 P236 Position #15 3.58E+06 1.41E+05 6.22E+07 4.27E+04 2.98E+02 2.03E+06 1.31E+04 1.79E+03 0.1155 P236 Position #16 3.61E+06 1.42E+05 6.28E+07 4.31E+04 3.01E+02 2.05E+06 1.32E+04 1.81E+03 0.1166 P236 Position #17 3.63E+06 1.43E+05 6.32E+07 4.33E+04 3.03E+02 2.06E+06 1.33E+04 1.82E+03 0.1172 P236 Position #18 3.66E+06 1.44E+05 6.37E+07 4.37E+04 3.05E+02 2.08E+06 1.34E+04 1.83E+03 0.1182 P236 Position #19 3.65E+06 1.44E+05 6.35E+07 4.36E+04 3.05E+02 2.08E+06 1.34E+04 1.83E+03 0.1179 P236 Position #20 3.47E+06 1.36E+05 6.03E+07 4.14E+04 2.89E+02 1.97E+06 1.27E+04 1.73E+03 0.1118 P236 Position #21 3.38E+06 1.33E+05 5.89E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.1092 P236 Position #22 3.33E+06 1.31E+05 5.79E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.1074 P236 Position #23 3.20E+06 1.26E+05 5.57E+07 3.82E+04 2.67E+02 1.82E+06 1.17E+04 1.60E+03 0.1033

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[110]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P236 Position #24 3.12E+06 1.23E+05 5.42E+07 3.72E+04 2.60E+02 1.77E+06 1.14E+04 1.56E+03 0.1006 P236 Position #25 3.18E+06 1.25E+05 5.52E+07 3.79E+04 2.65E+02 1.80E+06 1.16E+04 1.59E+03 0.1025 P236 Position #26 3.19E+06 1.25E+05 5.54E+07 3.80E+04 2.66E+02 1.81E+06 1.17E+04 1.59E+03 0.1028 P236 Position #27 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.1058 P236 Position #28 3.33E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.1073 P236 Position #29 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.1046 P236 Position #30 3.25E+06 1.28E+05 5.65E+07 3.88E+04 2.71E+02 1.85E+06 1.19E+04 1.63E+03 0.1049 P236 Position #31 3.31E+06 1.30E+05 5.75E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.1066 P236 Position #32 3.30E+06 1.30E+05 5.73E+07 3.93E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.1064 P236 Position #33 3.15E+06 1.24E+05 5.48E+07 3.76E+04 2.63E+02 1.79E+06 1.16E+04 1.58E+03 0.1017 P236 Position #34 3.28E+06 1.29E+05 5.71E+07 3.92E+04 2.74E+02 1.87E+06 1.20E+04 1.64E+03 0.1059 P236 Position #35 3.29E+06 1.29E+05 5.72E+07 3.92E+04 2.74E+02 1.87E+06 1.21E+04 1.64E+03 0.1061 P236 Position #36 3.20E+06 1.26E+05 5.56E+07 3.81E+04 2.66E+02 1.82E+06 1.17E+04 1.60E+03 0.1031 P236 Position #37 3.35E+06 1.32E+05 5.83E+07 4.00E+04 2.79E+02 1.90E+06 1.23E+04 1.68E+03 0.1082 P236 Position #38 3.24E+06 1.28E+05 5.64E+07 3.87E+04 2.70E+02 1.84E+06 1.19E+04 1.62E+03 0.1047 P236 Position #39 3.35E+06 1.32E+05 5.82E+07 3.99E+04 2.79E+02 1.90E+06 1.23E+04 1.67E+03 0.1080 P236 Position #40 3.40E+06 1.34E+05 5.92E+07 4.06E+04 2.84E+02 1.93E+06 1.25E+04 1.70E+03 0.1098 P236 Position #41 3.36E+06 1.32E+05 5.84E+07 4.01E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.1085 P236 Position #42 3.29E+06 1.30E+05 5.73E+07 3.93E+04 2.74E+02 1.87E+06 1.21E+04 1.65E+03 0.1063 P236 Position #43 3.34E+06 1.32E+05 5.81E+07 3.99E+04 2.79E+02 1.90E+06 1.23E+04 1.67E+03 0.1079 P236 Position #44 3.33E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.1076 P236 Position #45 3.30E+06 1.30E+05 5.74E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.1065 P236 Position #46 3.39E+06 1.34E+05 5.90E+07 4.05E+04 2.83E+02 1.93E+06 1.24E+04 1.70E+03 0.1095 P236 Position #47 3.41E+06 1.34E+05 5.94E+07 4.07E+04 2.85E+02 1.94E+06 1.25E+04 1.71E+03 0.1102 P236 Position #48 3.42E+06 1.35E+05 5.96E+07 4.09E+04 2.85E+02 1.95E+06 1.26E+04 1.71E+03 0.1105 P236 Position #49 3.33E+06 1.31E+05 5.80E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.1076 P236 Position #50 3.48E+06 1.37E+05 6.05E+07 4.15E+04 2.90E+02 1.98E+06 1.28E+04 1.74E+03 0.1123

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[111]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P235 Position #1 9.25E+06 3.64E+05 1.61E+08 1.10E+05 7.71E+02 5.25E+06 3.39E+04 4.62E+03 0.2984 P235 Position #2 4.94E+06 1.94E+05 8.59E+07 5.90E+04 4.12E+02 2.81E+06 1.81E+04 2.47E+03 0.1595 P235 Position #3 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.1278 P235 Position #4 4.01E+06 1.58E+05 6.97E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.1293 P235 Position #5 3.96E+06 1.56E+05 6.89E+07 4.73E+04 3.30E+02 2.25E+06 1.45E+04 1.98E+03 0.1279 P235 Position #6 3.99E+06 1.57E+05 6.94E+07 4.76E+04 3.32E+02 2.27E+06 1.46E+04 1.99E+03 0.1287 P235 Position #7 3.91E+06 1.54E+05 6.80E+07 4.67E+04 3.26E+02 2.22E+06 1.43E+04 1.96E+03 0.1262 P235 Position #8 3.95E+06 1.55E+05 6.87E+07 4.71E+04 3.29E+02 2.24E+06 1.45E+04 1.97E+03 0.1274 P235 Position #9 4.01E+06 1.58E+05 6.97E+07 4.78E+04 3.34E+02 2.28E+06 1.47E+04 2.00E+03 0.1294 P235 Position #10 4.00E+06 1.57E+05 6.95E+07 4.77E+04 3.33E+02 2.27E+06 1.47E+04 2.00E+03 0.1290 P235 Position #11 3.88E+06 1.53E+05 6.75E+07 4.63E+04 3.24E+02 2.21E+06 1.42E+04 1.94E+03 0.1253 P235 Position #12 3.89E+06 1.53E+05 6.77E+07 4.65E+04 3.24E+02 2.21E+06 1.43E+04 1.95E+03 0.1256 P235 Position #13 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.1249 P235 Position #14 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.22E+02 2.20E+06 1.42E+04 1.93E+03 0.1248 P235 Position #15 3.85E+06 1.51E+05 6.69E+07 4.59E+04 3.20E+02 2.18E+06 1.41E+04 1.92E+03 0.1241 P235 Position #16 3.78E+06 1.49E+05 6.57E+07 4.51E+04 3.15E+02 2.15E+06 1.39E+04 1.89E+03 0.1220 P235 Position #17 3.82E+06 1.50E+05 6.64E+07 4.56E+04 3.18E+02 2.17E+06 1.40E+04 1.91E+03 0.1232 P235 Position #18 3.77E+06 1.48E+05 6.56E+07 4.50E+04 3.15E+02 2.14E+06 1.38E+04 1.89E+03 0.1218 P235 Position #19 3.70E+06 1.45E+05 6.43E+07 4.41E+04 3.08E+02 2.10E+06 1.36E+04 1.85E+03 0.1193 P235 Position #20 3.53E+06 1.39E+05 6.13E+07 4.21E+04 2.94E+02 2.00E+06 1.29E+04 1.76E+03 0.1138 P235 Position #21 3.45E+06 1.36E+05 5.99E+07 4.11E+04 2.87E+02 1.96E+06 1.26E+04 1.72E+03 0.1112 P235 Position #22 3.37E+06 1.33E+05 5.86E+07 4.02E+04 2.81E+02 1.92E+06 1.24E+04 1.69E+03 0.1088 P235 Position #23 3.32E+06 1.31E+05 5.77E+07 3.96E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.1071 P235 Position #24 3.23E+06 1.27E+05 5.62E+07 3.85E+04 2.69E+02 1.83E+06 1.18E+04 1.61E+03 0.1042 P235 Position #25 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.1053 P235 Position #26 3.26E+06 1.28E+05 5.67E+07 3.89E+04 2.72E+02 1.85E+06 1.20E+04 1.63E+03 0.1053 P235 Position #27 3.39E+06 1.33E+05 5.89E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.1093

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[112]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P235 Position #28 3.30E+06 1.30E+05 5.74E+07 3.94E+04 2.75E+02 1.87E+06 1.21E+04 1.65E+03 0.1065 P235 Position #29 3.38E+06 1.33E+05 5.88E+07 4.04E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.1092 P235 Position #30 3.33E+06 1.31E+05 5.78E+07 3.97E+04 2.77E+02 1.89E+06 1.22E+04 1.66E+03 0.1073 P235 Position #31 3.31E+06 1.30E+05 5.75E+07 3.94E+04 2.75E+02 1.88E+06 1.21E+04 1.65E+03 0.1066 P235 Position #32 3.31E+06 1.30E+05 5.76E+07 3.95E+04 2.76E+02 1.88E+06 1.22E+04 1.66E+03 0.1069 P235 Position #33 3.25E+06 1.28E+05 5.66E+07 3.88E+04 2.71E+02 1.85E+06 1.19E+04 1.63E+03 0.1049 P235 Position #34 3.27E+06 1.29E+05 5.68E+07 3.90E+04 2.72E+02 1.86E+06 1.20E+04 1.63E+03 0.1055 P235 Position #35 3.27E+06 1.29E+05 5.69E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.1056 P235 Position #36 3.31E+06 1.30E+05 5.76E+07 3.95E+04 2.76E+02 1.88E+06 1.21E+04 1.66E+03 0.1069 P235 Position #37 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.1058 P235 Position #38 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.1090 P235 Position #39 3.33E+06 1.31E+05 5.79E+07 3.98E+04 2.78E+02 1.89E+06 1.22E+04 1.67E+03 0.1075 P235 Position #40 3.28E+06 1.29E+05 5.70E+07 3.91E+04 2.73E+02 1.86E+06 1.20E+04 1.64E+03 0.1058 P235 Position #41 3.28E+06 1.29E+05 5.71E+07 3.92E+04 2.74E+02 1.87E+06 1.20E+04 1.64E+03 0.1059 P235 Position #42 3.36E+06 1.32E+05 5.84E+07 4.01E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.1084 P235 Position #43 3.38E+06 1.33E+05 5.87E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.1090 P235 Position #44 3.36E+06 1.32E+05 5.84E+07 4.01E+04 2.80E+02 1.91E+06 1.23E+04 1.68E+03 0.1085 P235 Position #45 3.38E+06 1.33E+05 5.88E+07 4.03E+04 2.82E+02 1.92E+06 1.24E+04 1.69E+03 0.1090 P235 Position #46 3.52E+06 1.38E+05 6.12E+07 4.20E+04 2.93E+02 2.00E+06 1.29E+04 1.76E+03 0.1136 P235 Position #47 3.50E+06 1.38E+05 6.08E+07 4.17E+04 2.91E+02 1.99E+06 1.28E+04 1.75E+03 0.1128 P235 Position #48 3.43E+06 1.35E+05 5.97E+07 4.10E+04 2.86E+02 1.95E+06 1.26E+04 1.72E+03 0.1108 P235 Position #49 3.43E+06 1.35E+05 5.96E+07 4.09E+04 2.86E+02 1.95E+06 1.26E+04 1.71E+03 0.1106 P235 Position #50 3.62E+06 1.42E+05 6.30E+07 4.32E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.1168 P323 Position #1 1.40E+07 5.50E+05 2.43E+08 1.67E+05 1.16E+03 7.94E+06 5.12E+04 6.99E+03 0.4508 P323 Position #2 1.81E+07 7.12E+05 3.15E+08 2.16E+05 1.51E+03 1.03E+07 6.64E+04 9.06E+03 0.5843 P323 Position #3 6.56E+06 2.58E+05 1.14E+08 7.82E+04 5.47E+02 3.73E+06 2.40E+04 3.28E+03 0.2116 P323 Position #4 5.02E+06 1.98E+05 8.73E+07 5.99E+04 4.19E+02 2.85E+06 1.84E+04 2.51E+03 0.1620

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[113]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P323 Position #5 5.22E+06 2.05E+05 9.07E+07 6.22E+04 4.35E+02 2.96E+06 1.91E+04 2.61E+03 0.1683 P323 Position #6 6.08E+06 2.39E+05 1.06E+08 7.26E+04 5.07E+02 3.46E+06 2.23E+04 3.04E+03 0.1963 P323 Position #7 6.12E+06 2.41E+05 1.06E+08 7.30E+04 5.10E+02 3.47E+06 2.24E+04 3.06E+03 0.1973 P323 Position #8 6.28E+06 2.47E+05 1.09E+08 7.49E+04 5.23E+02 3.57E+06 2.30E+04 3.14E+03 0.2025 P323 Position #9 7.77E+06 3.06E+05 1.35E+08 9.27E+04 6.48E+02 4.42E+06 2.85E+04 3.89E+03 0.2508 P323 Position #10 7.51E+06 2.95E+05 1.31E+08 8.96E+04 6.26E+02 4.27E+06 2.75E+04 3.75E+03 0.2422 P323 Position #11 5.41E+06 2.13E+05 9.41E+07 6.46E+04 4.51E+02 3.08E+06 1.98E+04 2.71E+03 0.1746 P323 Position #12 4.81E+06 1.89E+05 8.37E+07 5.74E+04 4.01E+02 2.73E+06 1.76E+04 2.41E+03 0.1553 P323 Position #13 4.64E+06 1.83E+05 8.07E+07 5.54E+04 3.87E+02 2.64E+06 1.70E+04 2.32E+03 0.1498 P323 Position #14 4.49E+06 1.77E+05 7.80E+07 5.36E+04 3.74E+02 2.55E+06 1.65E+04 2.24E+03 0.1448 P323 Position #15 4.53E+06 1.78E+05 7.87E+07 5.40E+04 3.77E+02 2.57E+06 1.66E+04 2.26E+03 0.1461 P323 Position #16 4.59E+06 1.80E+05 7.98E+07 5.47E+04 3.82E+02 2.61E+06 1.68E+04 2.29E+03 0.1480 P323 Position #17 5.38E+06 2.11E+05 9.35E+07 6.41E+04 4.48E+02 3.05E+06 1.97E+04 2.69E+03 0.1735 P323 Position #18 7.88E+06 3.10E+05 1.37E+08 9.40E+04 6.57E+02 4.48E+06 2.89E+04 3.94E+03 0.2543 P323 Position #19 6.04E+06 2.38E+05 1.05E+08 7.20E+04 5.03E+02 3.43E+06 2.21E+04 3.02E+03 0.1948 P323 Position #20 4.95E+06 1.95E+05 8.60E+07 5.90E+04 4.12E+02 2.81E+06 1.81E+04 2.47E+03 0.1597 P323 Position #21 4.58E+06 1.80E+05 7.96E+07 5.46E+04 3.82E+02 2.60E+06 1.68E+04 2.29E+03 0.1478 P323 Position #22 4.07E+06 1.60E+05 7.07E+07 4.85E+04 3.39E+02 2.31E+06 1.49E+04 2.03E+03 0.1313 P323 Position #23 4.02E+06 1.58E+05 6.99E+07 4.80E+04 3.35E+02 2.28E+06 1.47E+04 2.01E+03 0.1297 P323 Position #24 3.87E+06 1.52E+05 6.73E+07 4.62E+04 3.23E+02 2.20E+06 1.42E+04 1.94E+03 0.1249 P323 Position #25 3.76E+06 1.48E+05 6.54E+07 4.49E+04 3.13E+02 2.14E+06 1.38E+04 1.88E+03 0.1214 P323 Position #26 4.11E+06 1.62E+05 7.15E+07 4.90E+04 3.43E+02 2.34E+06 1.51E+04 2.06E+03 0.1326 P323 Position #27 5.31E+06 2.09E+05 9.24E+07 6.34E+04 4.43E+02 3.02E+06 1.95E+04 2.66E+03 0.1714 P323 Position #28 4.62E+06 1.82E+05 8.03E+07 5.51E+04 3.85E+02 2.62E+06 1.69E+04 2.31E+03 0.1490 P323 Position #29 4.59E+06 1.81E+05 7.98E+07 5.48E+04 3.83E+02 2.61E+06 1.68E+04 2.30E+03 0.1481 P323 Position #30 4.00E+06 1.57E+05 6.96E+07 4.77E+04 3.34E+02 2.27E+06 1.47E+04 2.00E+03 0.1291 P323 Position #31 3.78E+06 1.49E+05 6.57E+07 4.51E+04 3.15E+02 2.15E+06 1.39E+04 1.89E+03 0.1220

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[114]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P323 Position #32 3.79E+06 1.49E+05 6.58E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.89E+03 0.1222 P323 Position #33 3.79E+06 1.49E+05 6.59E+07 4.52E+04 3.16E+02 2.15E+06 1.39E+04 1.90E+03 0.1223 P323 Position #34 3.80E+06 1.50E+05 6.61E+07 4.54E+04 3.17E+02 2.16E+06 1.39E+04 1.90E+03 0.1227 P323 Position #35 4.15E+06 1.63E+05 7.21E+07 4.95E+04 3.46E+02 2.36E+06 1.52E+04 2.07E+03 0.1338 P323 Position #36 5.16E+06 2.03E+05 8.98E+07 6.16E+04 4.30E+02 2.93E+06 1.89E+04 2.58E+03 0.1666 P323 Position #37 4.33E+06 1.70E+05 7.52E+07 5.16E+04 3.61E+02 2.46E+06 1.59E+04 2.16E+03 0.1396 P323 Position #38 4.18E+06 1.65E+05 7.27E+07 4.99E+04 3.49E+02 2.38E+06 1.53E+04 2.09E+03 0.1350 P323 Position #39 3.98E+06 1.57E+05 6.92E+07 4.75E+04 3.32E+02 2.26E+06 1.46E+04 1.99E+03 0.1284 P323 Position #40 3.99E+06 1.57E+05 6.94E+07 4.76E+04 3.33E+02 2.27E+06 1.46E+04 2.00E+03 0.1288 P323 Position #41 4.09E+06 1.61E+05 7.10E+07 4.87E+04 3.41E+02 2.32E+06 1.50E+04 2.04E+03 0.1318 P323 Position #42 4.09E+06 1.61E+05 7.10E+07 4.87E+04 3.41E+02 2.32E+06 1.50E+04 2.04E+03 0.1318 P323 Position #43 4.14E+06 1.63E+05 7.19E+07 4.93E+04 3.45E+02 2.35E+06 1.52E+04 2.07E+03 0.1334 P323 Position #44 4.27E+06 1.68E+05 7.43E+07 5.10E+04 3.56E+02 2.43E+06 1.57E+04 2.14E+03 0.1379 P323 Position #45 4.53E+06 1.78E+05 7.88E+07 5.41E+04 3.78E+02 2.57E+06 1.66E+04 2.27E+03 0.1462 P323 Position #46 6.59E+06 2.59E+05 1.15E+08 7.87E+04 5.50E+02 3.75E+06 2.42E+04 3.30E+03 0.2128 P323 Position #47 6.41E+06 2.52E+05 1.11E+08 7.64E+04 5.34E+02 3.64E+06 2.35E+04 3.20E+03 0.2067 P323 Position #48 5.33E+06 2.10E+05 9.27E+07 6.36E+04 4.44E+02 3.03E+06 1.95E+04 2.67E+03 0.1720 P323 Position #49 5.09E+06 2.00E+05 8.84E+07 6.07E+04 4.24E+02 2.89E+06 1.87E+04 2.54E+03 0.1641 P323 Position #50 5.58E+06 2.20E+05 9.71E+07 6.66E+04 4.65E+02 3.17E+06 2.05E+04 2.79E+03 0.1801 P323 Position #1 4.43E+06 1.74E+05 7.70E+07 5.28E+04 3.69E+02 2.52E+06 1.62E+04 2.21E+03 0.1429 P324 Position #1 1.17E+07 4.62E+05 2.04E+08 1.40E+05 9.78E+02 6.67E+06 4.30E+04 5.87E+03 0.3788 P324 Position #2 5.31E+06 2.09E+05 9.24E+07 6.34E+04 4.43E+02 3.02E+06 1.95E+04 2.66E+03 0.1714 P324 Position #3 4.22E+06 1.66E+05 7.33E+07 5.03E+04 3.51E+02 2.40E+06 1.55E+04 2.11E+03 0.1360 P324 Position #4 4.34E+06 1.71E+05 7.54E+07 5.18E+04 3.62E+02 2.47E+06 1.59E+04 2.17E+03 0.1400 P324 Position #5 4.30E+06 1.69E+05 7.47E+07 5.13E+04 3.58E+02 2.44E+06 1.58E+04 2.15E+03 0.1386 P324 Position #6 4.13E+06 1.62E+05 7.18E+07 4.92E+04 3.44E+02 2.35E+06 1.51E+04 2.06E+03 0.1332 P324 Position #7 4.04E+06 1.59E+05 7.03E+07 4.82E+04 3.37E+02 2.30E+06 1.48E+04 2.02E+03 0.1304

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[115]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P324 Position #8 4.29E+06 1.69E+05 7.45E+07 5.12E+04 3.57E+02 2.44E+06 1.57E+04 2.14E+03 0.1383 P324 Position #9 4.59E+06 1.80E+05 7.97E+07 5.47E+04 3.82E+02 2.61E+06 1.68E+04 2.29E+03 0.1480 P324 Position #10 4.17E+06 1.64E+05 7.24E+07 4.97E+04 3.47E+02 2.37E+06 1.53E+04 2.08E+03 0.1344 P324 Position #11 3.98E+06 1.57E+05 6.92E+07 4.75E+04 3.32E+02 2.26E+06 1.46E+04 1.99E+03 0.1284 P324 Position #12 4.09E+06 1.61E+05 7.10E+07 4.87E+04 3.41E+02 2.32E+06 1.50E+04 2.04E+03 0.1318 P324 Position #13 4.03E+06 1.59E+05 7.01E+07 4.81E+04 3.36E+02 2.29E+06 1.48E+04 2.02E+03 0.1302 P324 Position #14 4.09E+06 1.61E+05 7.11E+07 4.88E+04 3.41E+02 2.32E+06 1.50E+04 2.05E+03 0.1320 P324 Position #15 4.13E+06 1.63E+05 7.19E+07 4.93E+04 3.45E+02 2.35E+06 1.52E+04 2.07E+03 0.1334 P324 Position #16 4.22E+06 1.66E+05 7.34E+07 5.04E+04 3.52E+02 2.40E+06 1.55E+04 2.11E+03 0.1363 P324 Position #17 4.85E+06 1.91E+05 8.43E+07 5.79E+04 4.04E+02 2.76E+06 1.78E+04 2.43E+03 0.1565 P324 Position #18 5.13E+06 2.02E+05 8.93E+07 6.13E+04 4.28E+02 2.92E+06 1.88E+04 2.57E+03 0.1657 P324 Position #19 4.41E+06 1.74E+05 7.68E+07 5.27E+04 3.68E+02 2.51E+06 1.62E+04 2.21E+03 0.1425 P324 Position #20 4.23E+06 1.66E+05 7.35E+07 5.04E+04 3.52E+02 2.40E+06 1.55E+04 2.11E+03 0.1364 P324 Position #21 4.49E+06 1.77E+05 7.80E+07 5.36E+04 3.74E+02 2.55E+06 1.65E+04 2.24E+03 0.1448 P324 Position #22 4.16E+06 1.64E+05 7.24E+07 4.97E+04 3.47E+02 2.36E+06 1.53E+04 2.08E+03 0.1343 P324 Position #23 3.73E+06 1.47E+05 6.49E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.87E+03 0.1204 P324 Position #24 3.69E+06 1.45E+05 6.41E+07 4.40E+04 3.07E+02 2.10E+06 1.35E+04 1.84E+03 0.1190 P324 Position #25 3.67E+06 1.44E+05 6.38E+07 4.38E+04 3.06E+02 2.08E+06 1.35E+04 1.83E+03 0.1183 P324 Position #26 5.00E+06 1.97E+05 8.70E+07 5.97E+04 4.17E+02 2.84E+06 1.84E+04 2.50E+03 0.1615 P324 Position #27 6.30E+06 2.48E+05 1.10E+08 7.52E+04 5.25E+02 3.58E+06 2.31E+04 3.15E+03 0.2033 P324 Position #28 4.13E+06 1.63E+05 7.18E+07 4.93E+04 3.44E+02 2.35E+06 1.52E+04 2.07E+03 0.1333 P324 Position #29 3.71E+06 1.46E+05 6.45E+07 4.42E+04 3.09E+02 2.11E+06 1.36E+04 1.85E+03 0.1196 P324 Position #30 3.63E+06 1.43E+05 6.31E+07 4.33E+04 3.02E+02 2.06E+06 1.33E+04 1.81E+03 0.1171 P324 Position #31 3.53E+06 1.39E+05 6.14E+07 4.21E+04 2.94E+02 2.01E+06 1.30E+04 1.77E+03 0.1140 P324 Position #32 3.59E+06 1.41E+05 6.24E+07 4.28E+04 2.99E+02 2.04E+06 1.32E+04 1.79E+03 0.1158 P324 Position #33 3.73E+06 1.47E+05 6.48E+07 4.45E+04 3.11E+02 2.12E+06 1.37E+04 1.86E+03 0.1203 P324 Position #34 4.21E+06 1.65E+05 7.31E+07 5.02E+04 3.51E+02 2.39E+06 1.54E+04 2.10E+03 0.1357

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[116]

MEASUREMENT ID H-3 Co-60 Ni-63 Sr-90 Cs-134 Cs-137 Eu-152 Eu-154 OpSOF (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P324 Position #35 6.98E+06 2.74E+05 1.21E+08 8.32E+04 5.81E+02 3.96E+06 2.56E+04 3.49E+03 0.2251 P324 Position #36 8.05E+06 3.17E+05 1.40E+08 9.61E+04 6.71E+02 4.57E+06 2.95E+04 4.03E+03 0.2598 P324 Position #37 6.37E+06 2.51E+05 1.11E+08 7.61E+04 5.31E+02 3.62E+06 2.34E+04 3.19E+03 0.2057 P324 Position #38 4.67E+06 1.84E+05 8.12E+07 5.57E+04 3.89E+02 2.65E+06 1.71E+04 2.33E+03 0.1507 P324 Position #39 4.13E+06 1.62E+05 7.18E+07 4.92E+04 3.44E+02 2.35E+06 1.51E+04 2.06E+03 0.1332 P324 Position #40 3.76E+06 1.48E+05 6.55E+07 4.49E+04 3.14E+02 2.14E+06 1.38E+04 1.88E+03 0.1215 P324 Position #41 3.69E+06 1.45E+05 6.42E+07 4.41E+04 3.08E+02 2.10E+06 1.35E+04 1.85E+03 0.1192 P324 Position #42 3.72E+06 1.46E+05 6.47E+07 4.44E+04 3.10E+02 2.12E+06 1.37E+04 1.86E+03 0.1201 P324 Position #43 4.20E+06 1.65E+05 7.30E+07 5.01E+04 3.50E+02 2.39E+06 1.54E+04 2.10E+03 0.1355 P324 Position #44 7.17E+06 2.82E+05 1.25E+08 8.55E+04 5.97E+02 4.07E+06 2.63E+04 3.58E+03 0.2313 P324 Position #45 6.00E+06 2.36E+05 1.04E+08 7.16E+04 5.00E+02 3.41E+06 2.20E+04 3.00E+03 0.1935 P324 Position #46 4.43E+06 1.74E+05 7.70E+07 5.28E+04 3.69E+02 2.51E+06 1.62E+04 2.21E+03 0.1428 P324 Position #47 4.34E+06 1.71E+05 7.54E+07 5.17E+04 3.61E+02 2.46E+06 1.59E+04 2.17E+03 0.1399 P324 Position #48 4.74E+06 1.86E+05 8.24E+07 5.65E+04 3.95E+02 2.69E+06 1.74E+04 2.37E+03 0.1528 P324 Position #49 5.99E+06 2.36E+05 1.04E+08 7.15E+04 4.99E+02 3.40E+06 2.20E+04 2.99E+03 0.1932 P324 Position #50 5.70E+06 2.24E+05 9.91E+07 6.80E+04 4.75E+02 3.24E+06 2.09E+04 2.85E+03 0.1839 P220 By Direct Scan 1.04E+05 4.08E+03 1.80E+06 1.24E+03 8.65E+00 5.90E+04 3.81E+02 5.19E+01 0.0033

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[117]

ATTACHMENT 3 SIGN TEST

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[118]

Sign Test Unit 2 Containment Basement Penetrations Survey Area 02112 Description Unit 2 Containment Basement Survey Unit S1-02112F Description Penetrations Classification 1

Type I Error 0.05

  1. of Measurements 369 SOF 1-Ws Sign SOF 1-Ws Sign (Ws)

(Ws) 0 0.6849 0.32

+1 185 0.1179 0.88

+1 1

0.0947 0.91

+1 186 0.1118 0.89

+1 2

0.0603 0.94

+1 187 0.1092 0.89

+1 3

0.0602 0.94

+1 188 0.1074 0.89

+1 4

0.0529 0.95

+1 189 0.1033 0.90

+1 5

0.0557 0.94

+1 190 0.1006 0.90

+1 6

0.0597 0.94

+1 191 0.1025 0.90

+1 7

0.0686 0.93

+1 192 0.1028 0.90

+1 8

0.1310 0.87

+1 193 0.1058 0.89

+1 9

0.0401 0.96

+1 194 0.1073 0.89

+1 10 0.0500 0.95

+1 195 0.1046 0.90

+1 11 0.0571 0.94

+1 196 0.1049 0.90

+1 12 0.0696 0.93

+1 197 0.1066 0.89

+1 13 0.1847 0.82

+1 198 0.1064 0.89

+1 14 0.0902 0.91

+1 199 0.1017 0.90

+1 15 0.0525 0.95

+1 200 0.1059 0.89

+1 16 0.0467 0.95

+1 201 0.1061 0.89

+1 17 0.0413 0.96

+1 202 0.1031 0.90

+1 18 0.1021 0.90

+1 203 0.1082 0.89

+1 19 0.0588 0.94

+1 204 0.1047 0.90

+1 20 0.0576 0.94

+1 205 0.1080 0.89

+1 21 0.0532 0.95

+1 206 0.1098 0.89

+1 22 0.0547 0.95

+1 207 0.1085 0.89

+1 23 0.1656 0.83

+1 208 0.1063 0.89

+1 24 0.0026 1.00

+1 209 0.1079 0.89

+1 25 0.0162 0.98

+1 210 0.1076 0.89

+1 26 0.0110 0.99

+1 211 0.1065 0.89

+1 27 0.1197 0.88

+1 212 0.1095 0.89

+1 28 0.0451 0.95

+1 213 0.1102 0.89

+1

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[119]

SOF 1-Ws Sign SOF 1-Ws Sign (Ws)

(Ws) 29 0.0416 0.96

+1 214 0.1105 0.89

+1 30 0.0432 0.96

+1 215 0.1076 0.89

+1 31 0.0036 1.00

+1 216 0.1123 0.89

+1 32 0.0028 1.00

+1 217 0.2984 0.70

+1 33 0.0035 1.00

+1 218 0.1595 0.84

+1 34 0.0038 1.00

+1 219 0.1278 0.87

+1 35 0.0031 1.00

+1 220 0.1293 0.87

+1 36 0.0043 1.00

+1 221 0.1279 0.87

+1 37 0.0065 0.99

+1 222 0.1287 0.87

+1 38 0.0062 0.99

+1 223 0.1262 0.87

+1 39 0.0035 1.00

+1 224 0.1274 0.87

+1 40 0.0041 1.00

+1 225 0.1294 0.87

+1 41 0.0022 1.00

+1 226 0.1290 0.87

+1 42 0.0016 1.00

+1 227 0.1253 0.87

+1 43 0.0022 1.00

+1 228 0.1256 0.87

+1 44 0.4894 0.51

+1 229 0.1249 0.88

+1 45 0.0969 0.90

+1 230 0.1248 0.88

+1 46 0.0729 0.93

+1 231 0.1241 0.88

+1 47 0.0667 0.93

+1 232 0.1220 0.88

+1 48 0.1951 0.80

+1 233 0.1232 0.88

+1 49 0.0664 0.93

+1 234 0.1218 0.88

+1 50 0.0569 0.94

+1 235 0.1193 0.88

+1 51 0.0699 0.93

+1 236 0.1138 0.89

+1 52 0.3264 0.67

+1 237 0.1112 0.89

+1 53 0.0691 0.93

+1 238 0.1088 0.89

+1 54 0.0519 0.95

+1 239 0.1071 0.89

+1 55 0.0601 0.94

+1 240 0.1042 0.90

+1 56 0.2296 0.77

+1 241 0.1053 0.89

+1 57 0.0751 0.92

+1 242 0.1053 0.89

+1 58 0.0712 0.93

+1 243 0.1093 0.89

+1 59 0.0856 0.91

+1 244 0.1065 0.89

+1 60 0.3098 0.69

+1 245 0.1092 0.89

+1 61 0.0736 0.93

+1 246 0.1073 0.89

+1 62 0.0632 0.94

+1 247 0.1066 0.89

+1

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[120]

SOF 1-Ws Sign SOF 1-Ws Sign (Ws)

(Ws) 63 0.0723 0.93

+1 248 0.1069 0.89

+1 64 0.4309 0.57

+1 249 0.1049 0.90

+1 65 0.0599 0.94

+1 250 0.1055 0.89

+1 66 0.0411 0.96

+1 251 0.1056 0.89

+1 67 0.0420 0.96

+1 252 0.1069 0.89

+1 68 0.0404 0.96

+1 253 0.1058 0.89

+1 69 0.5728 0.43

+1 254 0.1090 0.89

+1 70 0.0668 0.93

+1 255 0.1075 0.89

+1 71 0.0476 0.95

+1 256 0.1058 0.89

+1 72 0.0455 0.95

+1 257 0.1059 0.89

+1 73 0.0452 0.95

+1 258 0.1084 0.89

+1 74 0.6683 0.33

+1 259 0.1090 0.89

+1 75 0.2201 0.78

+1 260 0.1085 0.89

+1 76 0.2904 0.71

+1 261 0.1090 0.89

+1 77 0.2612 0.74

+1 262 0.1136 0.89

+1 78 0.2201 0.78

+1 263 0.1128 0.89

+1 79 0.3023 0.70

+1 264 0.1108 0.89

+1 80 0.4004 0.60

+1 265 0.1106 0.89

+1 81 0.0475 0.95

+1 266 0.1168 0.88

+1 82 0.0381 0.96

+1 267 0.4508 0.55

+1 83 0.0355 0.96

+1 268 0.5843 0.42

+1 84 0.0390 0.96

+1 269 0.2116 0.79

+1 85 0.3925 0.61

+1 270 0.1620 0.84

+1 86 0.0593 0.94

+1 271 0.1683 0.83

+1 87 0.0504 0.95

+1 272 0.1963 0.80

+1 88 0.0544 0.95

+1 273 0.1973 0.80

+1 89 0.0465 0.95

+1 274 0.2025 0.80

+1 90 0.3197 0.68

+1 275 0.2508 0.75

+1 91 0.0585 0.94

+1 276 0.2422 0.76

+1 92 0.0491 0.95

+1 277 0.1746 0.83

+1 93 0.0515 0.95

+1 278 0.1553 0.84

+1 94 0.0501 0.95

+1 279 0.1498 0.85

+1 95 0.0109 0.99

+1 280 0.1448 0.86

+1 96 0.0023 1.00

+1 281 0.1461 0.85

+1

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[121]

SOF 1-Ws Sign SOF 1-Ws Sign (Ws)

(Ws) 97 0.0023 1.00

+1 282 0.1480 0.85

+1 98 0.0015 1.00

+1 283 0.1735 0.83

+1 99 0.0019 1.00

+1 284 0.2543 0.75

+1 100 0.0017 1.00

+1 285 0.1948 0.81

+1 101 0.0019 1.00

+1 286 0.1597 0.84

+1 102 0.0014 1.00

+1 287 0.1478 0.85

+1 103 0.0014 1.00

+1 288 0.1313 0.87

+1 104 0.0014 1.00

+1 289 0.1297 0.87

+1 105 0.0015 1.00

+1 290 0.1249 0.88

+1 106 0.0023 1.00

+1 291 0.1214 0.88

+1 107 0.0013 1.00

+1 292 0.1326 0.87

+1 108 0.0017 1.00

+1 293 0.1714 0.83

+1 109 0.0042 1.00

+1 294 0.1490 0.85

+1 110 0.0018 1.00

+1 295 0.1481 0.85

+1 111 0.0018 1.00

+1 296 0.1291 0.87

+1 112 0.0029 1.00

+1 297 0.1220 0.88

+1 113 0.0090 0.99

+1 298 0.1222 0.88

+1 114 0.0067 0.99

+1 299 0.1223 0.88

+1 115 0.0021 1.00

+1 300 0.1227 0.88

+1 116 0.0072 0.99

+1 301 0.1338 0.87

+1 117 0.3878 0.61

+1 302 0.1666 0.83

+1 118 0.1794 0.82

+1 303 0.1396 0.86

+1 119 0.1330 0.87

+1 304 0.1350 0.87

+1 120 0.1294 0.87

+1 305 0.1284 0.87

+1 121 0.1300 0.87

+1 306 0.1288 0.87

+1 122 0.1258 0.87

+1 307 0.1318 0.87

+1 123 0.1228 0.88

+1 308 0.1318 0.87

+1 124 0.1205 0.88

+1 309 0.1334 0.87

+1 125 0.1259 0.87

+1 310 0.1379 0.86

+1 126 0.1214 0.88

+1 311 0.1462 0.85

+1 127 0.1202 0.88

+1 312 0.2128 0.79

+1 128 0.1243 0.88

+1 313 0.2067 0.79

+1 129 0.1246 0.88

+1 314 0.1720 0.83

+1 130 0.1217 0.88

+1 315 0.1641 0.84

+1

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[122]

SOF 1-Ws Sign SOF 1-Ws Sign (Ws)

(Ws) 131 0.1264 0.87

+1 316 0.1801 0.82

+1 132 0.1209 0.88

+1 317 0.1429 0.86

+1 133 0.1239 0.88

+1 318 0.3788 0.62

+1 134 0.1307 0.87

+1 319 0.1714 0.83

+1 135 0.1269 0.87

+1 320 0.1360 0.86

+1 136 0.1177 0.88

+1 321 0.1400 0.86

+1 137 0.1073 0.89

+1 322 0.1386 0.86

+1 138 0.1081 0.89

+1 323 0.1332 0.87

+1 139 0.1064 0.89

+1 324 0.1304 0.87

+1 140 0.1029 0.90

+1 325 0.1383 0.86

+1 141 0.1066 0.89

+1 326 0.1480 0.85

+1 142 0.1036 0.90

+1 327 0.1344 0.87

+1 143 0.1064 0.89

+1 328 0.1284 0.87

+1 144 0.1068 0.89

+1 329 0.1318 0.87

+1 145 0.1072 0.89

+1 330 0.1302 0.87

+1 146 0.1046 0.90

+1 331 0.1320 0.87

+1 147 0.1046 0.90

+1 332 0.1334 0.87

+1 148 0.1052 0.89

+1 333 0.1363 0.86

+1 149 0.1041 0.90

+1 334 0.1565 0.84

+1 150 0.1039 0.90

+1 335 0.1657 0.83

+1 151 0.1044 0.90

+1 336 0.1425 0.86

+1 152 0.1057 0.89

+1 337 0.1364 0.86

+1 153 0.1051 0.89

+1 338 0.1448 0.86

+1 154 0.1045 0.90

+1 339 0.1343 0.87

+1 155 0.1074 0.89

+1 340 0.1204 0.88

+1 156 0.1039 0.90

+1 341 0.1190 0.88

+1 157 0.1059 0.89

+1 342 0.1183 0.88

+1 158 0.1053 0.89

+1 343 0.1615 0.84

+1 159 0.1058 0.89

+1 344 0.2033 0.80

+1 160 0.1047 0.90

+1 345 0.1333 0.87

+1 161 0.1089 0.89

+1 346 0.1196 0.88

+1 162 0.1052 0.89

+1 347 0.1171 0.88

+1 163 0.1074 0.89

+1 348 0.1140 0.89

+1 164 0.1078 0.89

+1 349 0.1158 0.88

+1

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[123]

SOF 1-Ws Sign SOF 1-Ws Sign (Ws)

(Ws) 165 0.1042 0.90

+1 350 0.1203 0.88

+1 166 0.1055 0.89

+1 351 0.1357 0.86

+1 167 0.3366 0.66

+1 352 0.2251 0.77

+1 168 0.1801 0.82

+1 353 0.2598 0.74

+1 169 0.1292 0.87

+1 354 0.2057 0.79

+1 170 0.1279 0.87

+1 355 0.1507 0.85

+1 171 0.1269 0.87

+1 356 0.1332 0.87

+1 172 0.1234 0.88

+1 357 0.1215 0.88

+1 173 0.1179 0.88

+1 358 0.1192 0.88

+1 174 0.1173 0.88

+1 359 0.1201 0.88

+1 175 0.1155 0.88

+1 360 0.1355 0.86

+1 176 0.1169 0.88

+1 361 0.2313 0.77

+1 177 0.1132 0.89

+1 362 0.1935 0.81

+1 178 0.1158 0.88

+1 363 0.1428 0.86

+1 179 0.1169 0.88

+1 364 0.1399 0.86

+1 180 0.1148 0.89

+1 365 0.1528 0.85

+1 181 0.1155 0.88

+1 366 0.1932 0.81

+1 182 0.1166 0.88

+1 367 0.1839 0.82

+1 183 0.1172 0.88

+1 368 0.0033 1.00

+1 184 0.1182 0.88

+1 369 0.0000 1.00

+1 Number of Positive Differences (S+) =

369 Critical Value =

200 Survey Unit Meets the Acceptance Criteria

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[124]

ATTACHMENT 4 QC DATA

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[125]

Duplicate Sample Assessment Form Duplicate Sample Assessment Form Survey Unit #:

02112 Survey Unit Name:

U2 Containment Building Penetrations Sample Plan#:

S102112AF Sample

Description:

Comparison of replicate measurements collected from measurement locations P254, Position #4, 4'; P242, Position #5, 4'; P237, Position #6, 15'; P237, Position #36, 35'; P237, Position #46, 45'; P236, Position #16, 15'; P236, Position

  1. 28, 27'; P236, Position #28, 27'; P236, Position #42, 41'; P235, Position #18, 17'; P235, Position #33, 32'; P235, Position #45, 44';

P323, Position #14, 13'; P323, Position #28, 27'; P323, Position #42, 41'; P324, Position #14, 13'; P324, Position #27, 26'; P324, Position #41, 40'; P287, Position #5, 4'; P203, Position #5, 4'; P267 Standard Measurement Duplicate ID Activity Value

+20%

-20%

ID Activity Value Acceptable (Y/N)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

P254, Position #5, 4' 8.19E+05 9.83E+05 6.55E+05 P254, Position #5, 4' QC 8.21E+05 Y

P242, Position #5, 4' 9.49E+05 1.14E+06 7.59E+05 P242, Position #5, 4' QC 9.49E+05 Y

P237, Position #16, 15' 2.29E+06 2.75E+06 1.83E+06 P237, Position #16, 15' QC 2.31E+06 Y

P237, Position #36, 35' 2.00E+06 2.40E+06 1.60E+06 P237, Position #36, 35' QC 2.03E+06 Y

P237, Position #46, 45' 2.00E+06 2.39E+06 1.60E+06 P237, Position #46, 45' QC 2.02E+06 Y

P236, Position #16, 15' 2.21E+06 2.65E+06 1.77E+06 P236, Position #16, 15' QC 2.23E+06 Y

P236, Position #28, 27' 2.04E+06 2.44E+06 1.63E+06 P236, Position #28, 27' QC 1.97E+06 Y

P236, Position #42, 41' 2.01E+06 2.42E+06 1.61E+06 P236, Position #42, 41' QC 2.02E+06 Y

P235, Position #18, 17' 2.31E+06 2.77E+06 1.85E+06 P235, Position #18, 17' QC 2.38E+06 Y

P235, Position #33, 32' 1.99E+06 2.39E+06 1.59E+06 P235, Position #33, 32' QC 2.09E+06 Y

P235, Position #45, 44' 2.07E+06 2.48E+06 1.65E+06 P235, Position #45, 44' QC 2.07E+06 Y

P323, Position #14, 13' 2.75E+06 3.30E+06 2.20E+06 P323, Position #14, 13' QC 2.77E+06 Y

P323, Position #28, 27' 2.82E+06 3.39E+06 2.26E+06 P323, Position #28, 27' QC 2.81E+06 Y

P323, Position #42, 41' 2.53E+06 3.04E+06 2.02E+06 P323, Position #42, 41' QC 2.51E+06 Y

P324, Position #14, 13' 2.50E+06 3.00E+06 2.00E+06 P324, Position #14, 13' QC 2.47E+06 Y

P324, Position #27, 26' 3.85E+06 4.63E+06 3.08E+06 P324, Position #27, 26' QC 2.55E+06 N

P324, Position #41, 40' 2.26E+06 2.71E+06 1.81E+06 P324, Position #41, 40' QC 2.27E+06 Y

P287, Position #5, 4' 3.50E+06 4.20E+06 2.80E+06 P287, Position #5, 4' QC 3.53E+06 Y

P203, Position #5, 4' 1.94E+06 2.32E+06 1.55E+06 P203, Position #5, 4' QC 1.89E+06 Y

P267 7.24E+04 8.69E+04 5.79E+04 P267 QC 7.44E+04 Y

Comments/Corrective Actions: The replicate measurement results are in acceptable agreement with the exception of measurement position 27 for 26 inch pipe P324. While the replicate measurement did fall out of the +20% range, the detector successfully passed the post use response check. The discrepancy was attributed to differing geometry and no further action was deemed necessary.

The acceptance criteria for replicate static measurements and scan surveys is that the same conclusion is reached for each measurement. This is defined as + 20% of the standard Performed By:

Date:

Reviewed By:

Date:

2/28/2019 2/28/2019

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT S1-02112F

[126]

ATTACHMENT 5 GRAPHICAL PRESENTATIONS

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[127]

QUANTILE PLOT FOR Co-60 Survey Unit: S1-02112A-F Survey Unit Name: Unit 2 CTMT Penetrations Mean:

1.48E+05 pCi/m2 0.00E+00 1.00E+05 2.00E+05 3.00E+05 4.00E+05 5.00E+05 6.00E+05 7.00E+05 8.00E+05 9.00E+05 0%

20%

40%

60%

80%

100%

Concentration (pCi/m2)

Percentage Quantile Plot For Co-60

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[128]

HISTOGRAM FOR Co-60 Survey Unit: S1-02112A-F Survey Unit Name: Unit 2 CTMT Penetrations Mean:

1.48E+05 pCi/m2 Median:

1.37E+05 pCi/m2 ST DEV:

1.10E+05 Skew:

2.69E+00 Upper Value Observation Frequency Observation %

8.51E+04 86 23%

1.69E+05 202 55%

2.52E+05 50 14%

3.36E+05 13 4%

4.19E+05 7

2%

5.03E+05 4

1%

5.86E+05 2

1%

6.70E+05 1

0%

7.53E+05 2

1%

8.37E+05 2

1%

TOTAL 369 100%

0%

10%

20%

30%

40%

50%

60%

8.51E+04 2.52E+05 4.19E+05 5.86E+05 7.53E+05 Frequency Upper End Value (pCi/m2)

Frequency Plot For Co-60

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[129]

QUANTILE PLOT FOR Cs-137 Survey Unit: S1-02112A-F Survey Unit Name: Unit 2 CTMT Penetrations Mean:

2.13E+06 pCi/m2 0.00E+00 2.00E+06 4.00E+06 6.00E+06 8.00E+06 1.00E+07 1.20E+07 1.40E+07 0%

20%

40%

60%

80%

100%

Concentration (pCi/m2)

Percentage Quantile Plot For Cs-137

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[130]

HISTOGRAM FOR Cs-137 Survey Unit: S1-02112A-F Survey Unit Name: Unit 2 CTMT Penetrations Mean:

2.13E+06 pCi/m2 Median:

1.98E+06 pCi/m2 ST DEV:

1.59E+06 Skew:

2.69E+00 Upper Value Observation Frequency Observation %

1.23E+06 86 23%

2.44E+06 202 55%

3.64E+06 50 14%

4.85E+06 13 4%

6.05E+06 7

2%

7.26E+06 4

1%

8.47E+06 2

1%

9.67E+06 1

0%

1.09E+07 2

1%

1.21E+07 2

1%

TOTAL 369 100%

0%

10%

20%

30%

40%

50%

60%

1.23E+06 3.64E+06 6.05E+06 8.47E+06 1.09E+07 Frequency Upper End Value (pCi/m2)

Frequency Plot For Cs-137

FSS RELEASE RECORD UNIT 2 CONTAINMENT BUILDING PENETRATIONS SURVEY UNIT SI-02112F

[131]

RETROSPECTIVE POWER CURVE