MONTHYEARML20195B3021999-05-0606 May 1999 Rev 0 to PECO-COLR-L2R5, COLR for Lgs,Unit 2 Reload 5 Cycle 6 ML20206D8971999-04-22022 April 1999 Rev 2 to PECO-COLR-L1R7, COLR for Lgs,Unit 2 Reload 7, Cycle 8 ML20198C7151998-12-10010 December 1998 Rev 1 to COLR for LGS Unit 1,Reload 7,Cycle 8 ML20199E3281998-11-23023 November 1998 Rev 2 to PECO-COLR-L2R4, COLR for Lgs,Unit 2,Reload 4,Cycle 5 ML20249B3501998-06-11011 June 1998 Rev 1 to PECO-COLR-L2R4, COLR for LGS Unit 2 Reload 4,Cycle 5 ML20199J6771998-01-0606 January 1998 Rev 3 to COLR for LGS Unit 1 Reload 6,Cycle 7 ML20249B3561997-05-0707 May 1997 Rev 0 to PECO-COLR-L1R7, COLR for LGS Unit 1 Reload 7,Cycle 8 ML20135C6901997-01-22022 January 1997 Rev 0 to COLR for Lgs,Unit 2,Reload 4,Cycle 5 ML20128L9651996-07-0808 July 1996 Rev 1 to PECO-COLR-L2R3, COLR for Limerick Generating Station Unit 2 Reload 3,Cycle 4 ML20100K3601996-01-23023 January 1996 COLR for LGS Unit 1 Reload 6,Cycle 7 ML20097D1821995-11-0101 November 1995 Rev 4 to PECO-COLR-L1R5, Core Operating Limits Rept for Limerick Generating Station Unit 1 Reload 5,Cycle 6 ML20097D7611995-08-23023 August 1995 COLR for Limerick Generating Station Unit 1 Reload 5,Cycle 6 ML20081B8261995-01-30030 January 1995 Rev 0 to COLR-L2R3, Core Operating Limits Rept for Limerick Generating Station Unit 2 Reload 3,Cycle 4 ML20064M5631994-02-17017 February 1994 COLR for Limerick Generating Station Unit 1,Reload 5,Cycle 6 ML20058J1851993-09-28028 September 1993 Rev 2 to Core Operating Limits Rept for Limerick Generating Station Unit 1 Reload 4,Cycle 5 ML20045D5981993-05-18018 May 1993 Rev 1 to COLR for Limerick Generating Station,Unit 2,Reload 2,Cycle 3. ML20116C0201992-09-28028 September 1992 Rev 4 to Core Operating Limits Rept for Limerick Generating Station,Unit2,Cycle 2 ML20101S6851992-05-11011 May 1992 Rev 0 to Core Operating Limits Rept for Limerick Generating Station,Unit 1,Reload 4,Cycle 5 ML20101S6861992-03-23023 March 1992 Rev 3 to Core Operating Limits Rept for Limerick Generating Station,Unit 2,Cycle 2 ML20092A9021991-12-31031 December 1991 Rev 2 to Core Operating Limits Rept for Limerick Generating Station,Unit 2,Cycle 2 ML20082M8231991-08-0909 August 1991 Rev 1 to Core Operating Limits Rept for Limerick Generating Station Unit 1,Reload 3,Cycle 4 ML20082M8271991-08-0909 August 1991 Rev 1 to Core Operating Limits Rept for Limerick Generating Station Unit 2,Cycle 2 ML20082F8751991-05-0808 May 1991 Rev 0 to Core Operating Limits Rept for Limerick Generating Station Unit 2,Cycle 2 ML20024F7931990-09-14014 September 1990 Core Operating Limits Rept for Limerick Generating Station Unit 1,Reload 3,Cycle 4, Rev 0 ML20043H0001990-05-15015 May 1990 Rev 1,to Core Operating Limits Rept for Unit 1,Reload 2, Cycle 3. ML20043H0011990-05-15015 May 1990 Rev 1 to, Core Operating Limits Rept for Unit 2,Cycle 1. ML20206A5761987-02-28028 February 1987 Rev 0 to Supplemental Reload Licensing Submittal for Limerick Generating Station Unit 1,Reload 1 1999-05-06
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217D1211999-09-30030 September 1999 Monthly Operating Repts for Sept 1999 for Lgs,Units 1 & 2. with ML20217A1691999-09-22022 September 1999 Part 21 Rept Re Engine Sys,Inc Controllers,Manufactured Between Dec 1997 & May 1999,that May Have Questionable Soldering Workmanship.Caused by Inadequate Personnel Training.Sent Rept to All Nuclear Customers ML20212A8861999-09-13013 September 1999 Safety Evaluation Authorizing First & Second 10 Yr Interval Inservice Insp Plan Requestss for Relief RR-01 ML20212A4481999-08-31031 August 1999 Monthly Operating Repts for Aug 1999 for Limerick Generating Station,Units 1 & 2.With ML20211E9891999-08-20020 August 1999 LGS Unit 2 Summary Rept for 970228 to 990525 Periodic ISI Rept Number 5 ML20210L7051999-07-31031 July 1999 Monthly Operating Repts for July 1999 for Limerick Generating Station,Units 1 & 2.With ML20209G0211999-06-30030 June 1999 GE-NE-B13-02010-33NP, Evaluation of Limerick Unit 2 Shroud Cracking for at Least One Fuel Cycle of Operation ML20209D7741999-06-30030 June 1999 Monthly Operating Repts for June 1999 for Limerick Generating Station,Units 1 & 2 ML20207H8331999-05-31031 May 1999 Non-proprietary Rev 0 to 1H61R, LGS - Unit 2 Core Shroud Ultrasonic Exam ML20195G4651999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Lgs,Units 1 & 2 ML20209D7791999-05-31031 May 1999 Revised Monthly Operating Repts for May 1999 for Limerick Generating Station,Units 1 & 2 ML20195B3021999-05-0606 May 1999 Rev 0 to PECO-COLR-L2R5, COLR for Lgs,Unit 2 Reload 5 Cycle 6 ML20206N2901999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for Limerick Generating Station,Units 1 & 2.With ML20195G4761999-04-30030 April 1999 Revised Monthly Operating Repts for Apr 1999 for Lgs,Units 1 & 2 ML20206D8971999-04-22022 April 1999 Rev 2 to PECO-COLR-L1R7, COLR for Lgs,Unit 2 Reload 7, Cycle 8 ML20205N8341999-04-0101 April 1999 Part 21 Rept Re Automatic Switch Co Nuclear Grade Series X206380 & X206832 Solenoid Valves Ordered Without Lubricants That Were Shipped with Std Lubrication to PECO & Tva.Affected Plants Were Notified ML20205N9311999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for Limerick Generating Station,Units 1 & 2.With ML20204G9851999-03-11011 March 1999 Safety Evaluation Re Revised Emergency Action Levels for Limerick Generating Station,Units 1 & 2 ML20207J7461999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for Limerick,Units 1 & 2.With ML20199G2371999-01-31031 January 1999 Rev 0 to NEDO-32645, Limerick Generating Station,Units 1 & 2 SRV Setpoint Tolerance Relaxation Licensing Rept ML20199L5301999-01-19019 January 1999 Special Rept:On 981214,seismic Monitor Was Declared Inoperable.Caused by Spectral Analyzer Not Running.Attempted to Reboot Sys & Then Sent Spectral Analyzer to Vendor for Analysis & Rework.Upgraded Sys Will Be Operable by 990331 B110078, Rev 1 to GE-NE-B1100786-01, Surveillance Specimen Program Evaluation for Limerick Generating Station,Unit 11998-12-31031 December 1998 Rev 1 to GE-NE-B1100786-01, Surveillance Specimen Program Evaluation for Limerick Generating Station,Unit 1 ML20205K0381998-12-31031 December 1998 PECO Energy 1998 Annual Rept. with ML20199F9611998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for Limerick Generating Station.With ML20198C7151998-12-10010 December 1998 Rev 1 to COLR for LGS Unit 1,Reload 7,Cycle 8 ML20198A3871998-12-10010 December 1998 Safety Evaluation Supporting Licensee Response to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power- Operated Gate Valves ML20206N4061998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for Limerick Generating Station,Units 1 & 2.With ML20199E3281998-11-23023 November 1998 Rev 2 to PECO-COLR-L2R4, COLR for Lgs,Unit 2,Reload 4,Cycle 5 ML20195C9771998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for Limerick Generating Station,Units 1 & 2.With ML20154H5691998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for Limerick Generating Station,Units 1 & 2.With ML20151X3511998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for Limerick Generating Station Units 1 & 2.With ML20237F0291998-08-27027 August 1998 Special Suppl Rept:On 960425,one Loose Part Detection Sys (Lpds) Was Identified to Be Inoperable.Initially Reported on 960531.Caused by Loose Parts Detector Module.Repairs Performed & Intermittent Ground No Longer Present ML20237D1041998-08-17017 August 1998 Books 1 & 2 of LGS Unit 1 Summary Rept for 960301-980521 Periodic ISI Rept 7 ML20237A7761998-08-10010 August 1998 SER Accepting Licensee Response to NRC Bulleting 95-002, Unexpected Clogging of RHR Pump Strainer While Operating in Suppression Pool Cooling Mode ML20236X7641998-07-31031 July 1998 Rev 0 to SIR-98-079, Response to NRC RAI Re RPV Structural Integrity at Lgs,Units 1 & 2 ML20237B4711998-07-31031 July 1998 Monthly Operating Repts for July 1998 for Limerick Generating Station,Units 1 & 2 ML20236N6751998-07-0909 July 1998 Part 21 & Deficiency Rept Re Notification of Potential Safety Hazard from Breakage of Cast Iron Suction Heads in Apkd Type Pumps.Caused by Migration of Suction Head Journal Sleeve Along Lower End of Pump Shaft.Will Inspect Pumps ML20151Z4881998-06-30030 June 1998 GE-NE-B1100786-02, Surveillance Specimen Program Evaluation for Limerick Generating Station,Unit 2 ML20236P9781998-06-30030 June 1998 Monthly Operating Repts for June 1998 for Limerick Generating Station,Units 1 & 2 ML20196K1801998-06-30030 June 1998 Annual 10CFR50.59 & Commitment Rev Rept for 970701-980630 for Lgs,Units 1 & 2. with ML20249B3501998-06-11011 June 1998 Rev 1 to PECO-COLR-L2R4, COLR for LGS Unit 2 Reload 4,Cycle 5 ML20249A5331998-05-31031 May 1998 Monthly Operating Repts for May 1998 for Limerick Units 1 & 2 ML20247M7071998-05-14014 May 1998 Safety Evaluation Supporting Amend 128 to License NPF-39 ML20217Q5101998-05-0404 May 1998 Safety Evaluation Supporting Amend 127 to License NPF-39 ML20247H5071998-04-30030 April 1998 Monthly Operating Repts for Apr 1998 for Limerick Generating Station ML20216F3601998-03-31031 March 1998 Monthly Operating Repts for Mar 1998 for Limerick Generating Station,Units 1 & 2 ML20217M0791998-03-31031 March 1998 Safety Evaluation Supporting Amends 125 & 89 to Licenses NPF-39 & NPF-85,respectively ML20217D5701998-03-20020 March 1998 Part 21 Rept 40 Re Governor Valve Stems Made of Inconel 718 Matl Which Caused Loss of Governor Control.Control Problems Have Been Traced to Valve Stems Mfg by Bw/Ip.Id of Carbon Spacer Should Be Increased to at Least .5005/.5010 ML20216F9471998-02-28028 February 1998 Monthly Operating Repts for Feb 1998 for Limerick Generating Station,Units 1 & 2 ML20216F3471998-02-28028 February 1998 Revised Monthly Operating Rept for Feb 1998 for Limerick Genrating Station,Unit 1 1999-09-30
[Table view] |
Text
.
~
. I PECO Fuel and Services Section' PECO-COLR-L1R4 LIR4 Core Operating Limits Report Page 1, Rev. 2 f
i I
\
i
?
i CORE OPERATING LIMITS REPORT -
t FOR l i
LIMERICK GENERATING STATION UNIT 1 j RELOAD 4, CYCLE 5 l i
i i
r Prepared By: k.
V J.
.W L. M' Hale Data: b38-93 '
Engineer ;
i Reviewed By: - -
Date: $!2[ 42 A. M. Olson / / '
Independent Reviewer r
'i I
Approved By: l # - Date: P[f.7
/ J. M. Carmod9 {
Manager ;
Nuclear Design Branch
~
931213044A 931202 5 PDR ADOCh 05000352 ,
t p PDR g f
.c . . . - . .
1 PECO Fuel and-Services Section' PECO-COLR-L1R4' L1R4 Core Operating Limits Report Page 2, Rev. 2 I
LIST OF EFFECTIVE PAGES l
Page(s) Revision 5-11, 18-22 0 1-4, 12-17 2 i
I e
i I;
)
i
PECO Fuel and Services Section's PECO-COLR-L1R4 L1R4 Core Operating Limits Report Page 3, Rev. 2 i
INTRODUCTION AND
SUMMARY
This report provides the cycle-specific parameter limits for: l Average Planar Linear Heat Generation Rate ( APLHGR) ; Minimum ;
4 Critical Power Ratio (MCPR); Flow Adjustment Factor (K ; Linear l Heat Generation Rate (LHGR) ; Rod Block Monitor flow biase,)d upscale 1 and high flow clamped setpoints; and Turbine Bypass Valve ,
parameters for Limerick Generating Station Unit 1, Cycle 5, Reload !
- 4. These values have been determined using NRC-approved ;
methodology and are established such that all applicable limits of i the plant safety analysis are met. I i
The revision, Rev. 2, accounts for the changes in MCPR due to the new upper limits for Increased Core Flow (from 105% to 110% of j rated core flow) and Final Feedwater Temperature Reduction (from j 60*F to 105*F). This revision makes changes to Rev. O of this !
document and not Rev. 1. Revision 1 was not issued.
This report is submitted in accordance with Technical Specification 6.9.1 of Reference (1). Preparation of this report j was performed in accordance with PECO Fuel Management Section j
. Procedure FM-105. j 4
l APLHGR LIMITS ,
The limiting APLHGR value for the most limiting lattice l (excluding natural uranium) of each fuel type as a function of i average planar exposure is given in Figures 1 through 6. These j figures are used when hand calculations are required as specified ;
in Technical Specification 3.2.1. The reduction factor for use i during single recirculation loop operation is given in Table 1. j l
l MCPR LIMITS The MCPR value for use in Technical Specification 3.2.3 for !
each fuel type is given in Figures 7 through 13. These values are j j based on the most limiting results provided in References 2 and 4. -
The K, core flow adjustment factor for use in Technical
. Specification 3.2.3 is given in Figure 14. j i
The MCPR values shown in these figures are the bounding values for Increased Core Flow (up to 110% of rated core flow), Rated Core l f Flow (100% of rated core flow), Extended Load Line (down to 87% of l rated core flow), Feedwater Temperature Reduction (up to 105*F), l J power coastdown, and a combination of all of these options. l However, Feedwater Heater Out-of-Service (FWHOOS) temperature ,
reduction is still limited to 60*F. The curves labelled " Increased l Core Flow and Feedwater Temperature Reduction" represent bounding i operating limit MCPRs for the ELL, RCF, ICF, and ICF plus FWTR '
operating domains. Curves are also provided for inoperable Recirc Pump Trip or inoperable Steam Bypass System. l i
PECO Fuel and Services Section's PECO-COLR-L1R4 LIR4 Core Operating Limits Report Page 4, Rev. 2 ;
BOD BLOCK MONITOR SETPOINTS The N value for the RBM flow b#ased upscale and high flow '
clamped setpoints for use in Technical Specification 3.3.6 is given in Table 2.
LINEAR HEAT GENERhTION RATES The LHGR value for use in Technical Specification 3.2.4 for i each fuel type is given in Table 3.
S_TJ:lR BYPASS SYSTEM OPERABILITY The operability requirements for the steam bypass system for use in Technical Specifications 3.7.8 and 4.7.8.C are found in Table 4. If these requirements cannot be met the MCPR limits for inoperable steam bypass system must be used.
REFERENCES i
=
- 1) " Technical Specifications and Bases for Limerick Generating ,
Station Unit 1", Docket No. 50-352 Appendix A to License No. NPF- ,
- 39. I i
- 2) " Supplemental Reload Licensing Report for Limerick l Generating Station Unit 1, Reload 4, Cycle 5", General Electric Company Document No. 23A7156, Rev. O.
- 3) " Basis of M. 'LJiGR Technical Specitications for Limerick .1", l NEDE-31401-P, E&A No. 4, April 1992. I
- 4) " Safety Review for Limerick Generating Station Units 1 and 2 110% Increased Core Flow Operation and Final Feedwater '
Temperature Reduction", General Electric Company Document No. NEDC-32224P, July 1993. 3 i
[
i i
i i
)
M: \f Ull\KMS\W51\ COL RR2. l1R b
- a w ..n.. , . , . ,
.}
PECO Fuel Management Section PECO-COLR-L1 R4' l t
L1R4 Core Operating Limits Report Page 12, Rev. 2 +
4 I
FIGURE 8 Has Been Deleted i From Revision 2 l 1
I I
l I
I I
j
, -c !
. 'i s -l 1
i PECO Fuel Management Sec; ion PECO-COLh-L1R4 l L1R4 Core Operating Limits Peport Page 13, Rev. 2 l 1.54 1,54 >
I i
1.52 - THIS FIGURE IS REFERRED TO BY .-
1.52 l TECHNICAL SPECIFICATION 3.2.3
,/ !
1.50 - - - - -
1.50 ;
.l i
- 1.48 -
otop --
- . 1.48 l
,9 # - ;
1.46 -- 1 - - -
1.46 pow3 '.
1.44 l - - - - - - - - - - - --
1.44 t
j CC / -
.i h 1.42 1.42 2 - 1 1.40 -- - - - - --- --- - -- --
1.40 ,
i 1.38 - - - - -- -- - --
1.38-1.36 -- ' - - - - - -
1.36 f j
1.34 - - - - - - - - - --
1.34 1.32 - - - - -
1.32 j 1.30 1.30 !
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 i I !
- i I
MCPR VS TAU FUEL TYPE GE11 i
OVITHOUT RPT and/or TBVOOS) l f
e FIGURE 9
'5
.I
?- , , . . _ , . , , .- .. , - _ . . i. . . - . _ - . - _ _ _ _-- - .
. . . . . . . . , _ . . _ _ . _ _ _ . - = . _ _ - _ _ . _ _ _ .- .
s FECO Fuel Management Section PECO-COLR-L1R4 L1R4 Core Operating Limits Report Page 14, Rev. 2 1.46 1,46 ,
1.44 -
THIS FIGURE IS REFERRED TO BY - _ _
3,44 ,
I !
TECHNICAL SPECIFICATION 3.2.3
~ -
- l 1.42 -- -
1.42 l 1.40 - -
1.40 1.38 - - --- - --
1.38 f 1.36 - -~ - - ---
1.36 a- - -
h 1.34 1.34
~
- - - - ~ - - --
2 ._ _ i BOC5 TO EOC5 t 1.32 1.32 1.30 - - - -- - - - - - - - - - - - - - - - - -
1.30 {
1.28 - - - - --- - -- - - - -- ~ - - -- -
1.28 -l
_ _ i 1.26 -- - - - - -- --- -- - - - - - - - - - - - - -
1.26 ,
1.24 -- -
1.24 i 1.22 1.22 '!
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 l T .l MCPR VS TAU f FUEL TYPES GE98, GE84WR, GE82WR, and BP8x8R j t i'
(INCREASED CORE FLOW and FEEDWATER TEMPERATURE REDUCTION)
( l FIGURE 10 f
6 t
. l
)
l b-PECO Fuel and Services Section PECO-COLR-L1R4 L1R4 Core Operating Umits Report Page 15, Rev. 2 I i
1.46 1.46 .,
1.44 -. THIS FIGURE IS REFERRED TO BY - ._
3,44 TECHNICAL SPECIFICATION 3.2.3 1.42 - - -
1.42 i i
1.40 -- --- -
1.40 l 1.38 --
,;3730socs-1.38 i
1.36 - - - - - - - -- -
1.36 t
- g. X' _
- c. 1.34 o 1.34 g j uworst-2 ..
1.32 ' -- -- - - --
1.32 l
.t 1.30 -- - - - - - --
1.30 ;
1.28 - - - - - -- - - - - --
1.28 1.26 - - - - - ~ - - - - - - -
1.26 i 1.24 - ' -
1.24 .
i 1.22 1.22 '
O 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 i
\
T MCPR VS TAU ;
FUEL TYPE GE9B .
(WITHOUT RPT and/or TBVOOS) l
)
FIGURE 11 l l
1 a
1
j
-s l PECO Fuel Management Section PECO-COLR-L184 .
L1R4 Core Operating Limits Report Page 16, Rev. 2 !
1.46 --
1,46 'l i
1.44 -
THIS FIGURE IS REFERRED TO BY _
3,44 l TECHNICAL SPECIFICATION 3.2.3 l
1.42 -
L - -
1.42' l 1.40 -
1.40 ,
i
@O Mgg737 To E 1.36 -
1.36 l
/ \
eccsTo tocs-20mg!
[1.34 o -
~ -
1.34 -
2 -
l 1.32 -- - - -- - - -
1,32 f
1.30 - -
c- 1.30-f 1.28 - --
1.28 1 26 -- --- - - - - - -~ --
1.26 'I f'
1.24 - --
1.24 i 1 ' ' ' ' ' ' ' '
1.22 1.22 i O U.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 i T l MCPR VS TAU ;
FUEL TYPE GE84WR .
(WITHOUT RPT and/or TSVOOS) .
-l ,
o FIGURE 12 I i
)
h
.t
~- !
i
. l DECO Fuel and Services Section PECO-COLR-L1R4 L1R4 Core Operating Umits Report Page 17, Rev. 2 j 1.46 1.46 ,f 1.44 -
THIS FIGURE IS REFERRED TO BY _ ---
1,44 .
TECHNICAL SPECIFICATION 3.2.3 1.42 -
1.42
^
1.40 - - - -
1.40 P
EOC&2%
1.36 - -~ - - - - - -
1.36 !
Q~ '!
Q. _ socg ro EOCE2p MwolsT -
o 1.34 1.34_
1 .
1.32 - - -- - --
1.32 .!
1 I
1.30 - - - - - - ----- -- --
-1.30 1.28 - -- - - - - - - -
--' 1.28 l t
1.26 - - - -
1.26 i 1.24 - -
1.24 ,
1.22 1.22 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 - j T !
t MCPR VS TAU ,
FUEL TYPES GE82WR and BP8x8R
]
(WiTHOUT RPT and/or TBVOOS) j ;
t FIGURE 13 !
I I