Ro:On 881005,eddy Current Exam of Steam Generator 24 Revealed 20 Defective Tubes of 204 Tubes Inspected in Row 1. Tubes Showed Indications of Single or Multiple Circumferential Cracking in Tangent Area
ML18093B213
Person / Time
Site: Salem PSEG icon.png
Issue date: 10/05/1988
From: Miller L
Public Service Enterprise Group
To: Russell W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 8810170502
Download: ML18093B213 (2)


Text

ACCELERATED .srRIBUTION DEMON.RATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8810170502 DOC.DATE: 88/10/05 NOTARIZED: NO DOCKET #

FACIL:50-311 Salem Nuclear Generating Station, Unit 2, Public Serv 05000311 AUTH.NAME AUTHOR AFFILIATION MILLER,L.K. Public Service Electric & Gas Co. of New Jersey RECIP.NAME RECIPIENT AFFILIATION RUSSELL,W.T. Region 1, Ofc of the Director

SUBJECT:

Notifies that 881005 eddy current exam of Steam Generator 24 revealed 20 defective tubes of 204 inspected in Row 1. R DISTRIBUTION CODE: IE29D COPIES RECEIVED:LTR 1-: ENCL 0 SIZE:---=-~1--,..-~~ I TITLE: Licensee Event Rept (50 DKT)-Prompt Notification/24-Hour Rept D

NOTES:

s RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL I INTERNAL: AEOD/DOA 2 1 A NRC OP CNTR 1 1 NRR/DOEA/TSB 11 1 1 D NRR/DREP/RAB 10 1 2 NRR/DRIS/SIB 9A 1 1 NUDOCS-ABSTRACT 1 1 D RES DEPY GI 1 1 RES/DSIR/EIB 1 1 s "EXTERNAL: H ST LOBBY WARD 1 LPDR 1 NRC PDR 1 NSIC 1 R

I D

s I

A D

NOl'E 'IO ALL "RIOO" RECIPIENTS:

D PIFASE HELP US 'IO REDUCE '1imm'E ! CDNI'ACT 'IHE IXXlJMENI' CDN.mOL DESK, RCX:l-1 Pl-37 (Dcr'. 20079) 'l'O ELIMINM'E !OtJR !mME FR:H DJ:S'l'RIBOTIClN s

LISTS FOR IXlCCMENl'S 'mtJ Ial'T NEED!

0 TOTAL NUMBER OF COPIES REQUIRED: LTTR 22 ENCL ~

OPS~G

  • Public Service Electric and Gas Company P.O. Box E Hancocks_Bridge, New Jersey 08038 Salem Generating Station October 5, 1988 Mr. W. T. Russell Regional Administrator USNRC, Region 1 475 Allendale Road King of Prussia, Pa. 19406

Dear Sir:

SALEM GENERATING STATION LICENSE NO. DPR-75 DOCKET NO. 50-311 UNIT NO. 2 TECHNICAL SPECIFICATION SURVEILLANCE PROMPT NOTIFICATION REQUIREMENT 4.4.6.4.B, TABLE 4.2-2 On October 5, 1988, eddy current examination of No. 24 Steam Generator (S/G) revealed twenty (20) defective tubes of 204 inspected in Row 1. The tubes showed indications of single or multiple circumferential cracking in the tangent area. As per Technical Specification Surveillance 4.4.6.2 this places the S/G in category C-3.

This notification is being made as required by Technical Specification Table 4.2-2 prompt notification (i.e., C-3 categorization) to the Nuclear Regulatory Commission pursuant to Technical Specification 6.9.1.8.

Sincerely yours, L. K. Miller General Manager -

Salem Operations MJP:pc 8810170502 881005 PDR ADOCK 05000311 P PDC The Energy People 95*2189 1 I; MJ 1 2*84