Text

Here are the changes requested upon the initial review. I will determine if more changes are required as I develop exam questions. The password is the same as before.

PVNGS Draft Outline Comments (completed 9/13/04)

Changes marked in red and line outs Operating Exam

1. The outline only shows one JPM as a repeat - Emergency/Abnormal Plant Evolutions (EAPE)

Item 3, A032 Loss of a Startup Channel During Refueling@ from the 2002 exam. However EAPE Item 1 (loss of inventory in the refuel pool) could possibly be similar to JPM B4 from the 2002 exam which dealt with loss of spent fuel pool level. I need to check this JPM once the exam comes in for review. This JPM is significantly different from the previous JPM given in 2002. (Completed)

2. Need K/A numbers for Systems and EAPE JPMs and importance ratings for all JPMs.

Completed on 9/9/04, when Phil sent in completed written and operating outline. Discussed this with him verbally. (Completed)

Written Exam

3. Reviewed the licensee random and systematic process for selecting K/As and I followed this up with a phone conversation. I have no concerns with their selection process. Ensured that their selection process was random and systematic all the way to the actual K/A selection.
4. Under the heading K/A Topic(s), include a short written description of the K/A.

(Completed)

5. For Tier 2 - K/A 034A1.02 similar to K/A 002A1.11 -> both deal with inventory loss. Need to review questions for these two K/As to ensure not oversampling. 002A1.11 rejected and resampled within the same sytem. 034A1.02 rejected and resampled within same system.

(Also, this is the same as item 6.b below) (Completed)

6. Possible duplication between written and operating outlines as follows:

a) JPM EAPE #3 (K/A 032AA2.02), loss of startup channel during refueling and written outline Tier 1, K/A 032AK3.02, guidance contained in EOP for loss of source-range nuclear instrumentation. 032AK3.02 rejected and resampled within SR NI system.

(Completed) b) JPM EAPE #1 (K/A 025AA1.02), loss of SDC - loss of inventory in refuel pool and written outline K/A 034A1.02 similar to K/A 002A1.11 -> both deal with inventory loss. Recommend changing one of the written K/As or the JPM. Oversampling on dealing with loss of inventory. 002A1.11 rejected and resampled within the same sytem.(Completed)

(Changed 034 Fuel Handling Equipment from A1.02 to A1.01, load limit KA)

7. Rejected a previous outline KA (Tier 2, 32002A1.11) as not being applicable to the LSRO Job Function and replaced with 32002K6.14. This was discussed via telecom with Mark Haire on 10/01/04.
8. Rejected a previous outline KA (Tier 1, 42032AK3.02). There is no EOP/AOP guidance for loss of SR NI. Another KA was randomly sampled from within the same system.

(42032AK201). Reviewed with Mark Haire on site the week of 11/30/04.

ES-701 LSRO PWR Written Examination Outline Form ES-701-2 Facility: PVNGS Units 1,2,3 Date of Exam: 12/13/04 - 12/16/04 K/A Category Points Tier K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G* Total 1.

1 2 1 2 2 2 10 Emergency &

Abnormal Plant Evolutions 2.

2 2 2 2 1 1 2 2 2 2 2 20 Plant Systems

3. Generic Knowledge and 1 2 3 4 GFE Abilities Categories 10 2 2 2 2 2 Note: 1. Ensure that at least one topic from every K/A category is sampled within each tier.
2. The point total for each tier in the proposed outline must match that specified in the table.

The final point total for each tier may deviate by +/-1 from that specified in the table based on NRC revisions.

The final exam must total 40 points.

3. Select topics from many systems and evolutions; avoid selecting more than two K/A topics from a given system (except fuel handling equipment) or evolution (except refueling accident).
4. The shaded areas are not applicable to the category/tier.

5.* The generic (G) K/As in Tiers 1 and 2 shall be selected from Section 2 of the K/A Catalog, but the topics must be relevant to the applicable evolution or system.

6. If the applicants have not previously taken the GFE, Tier 3 shall include basic reactor theory, component, and thermodynamic topics that apply to fuel handling operations.
7. Systems/evolutions within each tier are identified on the associated outline. Enter the K/A numbers, a brief description of each topic, the topics importance ratings (IR) for the SRO license level, and the point totals (#)

for each system and category. Enter the tier totals for each category in the table above.

8. For Tier 3, select topics from Section 2 of the K/A catalog, and enter the K/A numbers, descriptions, importance ratings, and point totals (#) on Form ES-701-3.
9. Refer to ES-401, Attachment 2, for guidance regarding the elimination of inappropriate K/A statements. The facility licensees JTA for fuel handlers should be used as the basis for eliminating or adding testable topics.

ES-701 LSRO PWR Written Examination Outline Emergency and Abnormal Plant Evolutions -Tier 1 Form ES-701-2 Question K1 K2 K3 A1 A2 G K/A Topic(s) IR #

2.4.15 Knowledge of communications procedures 1 000025 Loss of RHR Sys X associated with EOP implementation. 3.5 1 AA1.03 Ability to operate and / or monitor the following as 2 000026 Loss of X they apply to the Loss of Component Cooling 3.6 1 Component Cooling Water: SWS as a backup to the CCWS Water AK2.01 Knowledge of the interrelations between the Loss 3 000032 Loss of Source X of Source Range Nuclear Instrumentation and the 3.1 1 Range NI following: Power supplies, including proper switch positions.

AA2.02 Ability to determine and interpret the following as 4 000036 (BW/A08) Fuel X they apply to the Fuel Handling Incidents: 4.1 1 Handling Accident Occurrence of a fuel handling incident 5 000061 ARM System X AA1.01 Ability to operate and / or monitor the following as 3.6 1 Alarms they apply to the Area Radiation Monitoring (ARM)

System Alarms: Automatic actuation 000033 Loss of Intermediate Range NI 000055 Station Blackout AA2.08 Ability to determine and interpret the following as 6 000056 Loss of Offsite X they apply to the Loss of Offsite Power: 2.3* 1 Power Operational status of fuel-handling building exhaust fan 000057 Loss of Vital AC Inst. Bus AK1.01 Knowledge of the operational implications of the 7 000058 Loss of DC X following concepts as they apply to Loss of DC 3.1 1 Power Power: Battery charger equipment and instrumentation AK3.02 Knowledge of the reasons for the following 8 000062 Loss of Nuclear X responses as they apply to the Loss of Nuclear 3.9 1 Svc Water Service Water: The automatic actions (alignments) within the nuclear service water resulting from the actuation of the ESFAS 9 000065 Loss of X 2.1.27 Knowledge of system purpose and or function. 2.9 1 Instrument Air 000067 Plant Fire On Site AK2.03 Knowledge of the interrelations between the Loss 10 000069 (W/E14) Loss of X of Containment Integrity and the following: 2.9 1 CTMT Integrity Personnel access hatch and emergency access hatch W/E16 High Containment Radiation K/A Category Totals: 1 2 1 2 2 2 Tier Point Total: 10 Note:

  • items rated < 2.5 in the KA catalog have been rated > 2.5 for PVNGS LSROs JTA.

System 033 Loss of Intermediate Range NI and System W/E16 High Containment Radiation are not CE Systems and were therefore eliminated.

ES-701 LSRO PWR Written Examination Outline Emergency and Abnormal Plant Evolutions - Form ES-701-2 Tier 2 Question K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G K/A Topic(s) IR #

K6.03 Knowledge of the effect of a loss 11 005 Residual X or malfunction on the following 2.6 1 Heat Removal will have on the RHRS: RHR heat exchanger 2.2.31 Knowledge of procedures and 12 015 Nuclear X limitations involved in initial core 2.9 1 Instrumentation loading.

K5.04 Knowledge of the operational 2.3*

13 033 Spent Fuel X X implication of the following 2.9 2 14 Pool Cooling concepts as they apply to the Spent Fuel Pool Cooling System:

Keff A4.03 Ability to manually operate and/or monitor in the control room:

Support systems for fill and transfer of SFPCS water A3.01 Ability to monitor automatic 3.1 15 034 Fuel X X operation of the Fuel Handling 3.2 2 16 Handling System including: Travel limits Equipment A1.01 Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with operating the Fuel Handling System controls including: Load limits K4.06 Knowledge of containment 17 103 X system design feature(s) and/or 3.7 1 Containment interlock(s) which provide for the following: Containment isolation system 18 062 AC X A2.01 Ability to (a) predict the impacts of 3.9 1 Electrical the following malfunctions or Distribution operations on the ac distribution system; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Types of loads that, if de-energized, would degrade or hinder plant operation K2.01 Knowledge of bus power supplies 19 063 DC X to the following: Major DC loads 3.1 1 Electrical Distribution K6.14 Knowledge of the effect or a loss 20 002 Reactor X or malfunction on the following 2.8 1 Coolant RCS components: Core components A4.03 Ability to manually operate and/or 21 004 Chemical X monitor in the control room: 3.2 1 and Volume Construction and use of 1/M plots Control (inverse multiplication, criticality prediction method)

K4.06 Knowledge of CCWS design 22 008 Component X feature(s) and/or interlock(s) 2.6* 1 Cooling Water which provide for the following:

Auxiliary building CCWS isolation 23 013 Engineered X 2.2.25 Knowledge of bases in technical 3.7 1 Safety Features specifications for limiting Actuation conditions for operations and safety limits A3.07 Ability to monitor automatic 24 064 Emergency X operation of the ED/G system, 3.7 1 Diesel including: Load sequencing Generator

ES-701 LSRO PWR Written Examination Outline Emergency and Abnormal Plant Evolutions - Form ES-701-2 Tier 2 Question K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G K/A Topic(s) IR #

K1.04 Knowledge of the physical 25 072 Area X connections and/or cause effect 3.5 1 Radiation relationships between the ARM Monitoring system and the following systems:

Control room ventilation K1.01 Knowledge of the physical 26 076 Service X connections and/or cause- effect 3.3 1 Water relationships between the SWS and the following systems: CCW system 078 Instrument Air 079 Station Air K3.01 Knowledge of the effect that a loss 27 086 Fire X or malfunction of the Fire 3.2 1 Protection Protection System will have on the following: Shutdown capability with redundant equipment K3.02 Knowledge of the effect that a loss 28 006 ECCS X or malfunction of the ECCS will 4.4 1 have on the following: Fuel A2.05 Ability to (a) predict the impacts of 29 022 X the following malfunctions or 3.5 1 Containment operations on the CCS; and (b)

Cooling based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:

Major leak in CCS K2.01 Knowledge of bus power supplies 30 026 X to the following: Containment 3.6 1 Containment spray pumps Spray K/A Category 2 2 2 2 1 2 1 2 2 2 2 Tier Point Total: 20 Totals:

System 026, Containment Spray has been added per NOTE 9 of ES 701-2: The facility licensees JTA for fuel handlers should be used as the basis for eliminating or adding testable topics.

Systems 006 ECCS and 022 Containment Cooling are more IPE/PRA risk related systems than 078 Instrument Air and 070 Station Air Systems and were therefore used to replace these two systems. These two systems are also part of the LSRO JTA. System 070 Station Air System is not part of the LSRO JTA.

Note:

  • items rated < 2.5 in the KA catalog have been rated > 2.5 for PVNGS LSROs JTA.

ES-701 LSRO Generic Knowledge and Abilities Outline (Tier 3) Form ES-701-3 Facility: PVNGS Units 1,2,3 Date of Examination: 12/13/04-12/16/04 Category K/A # Topic IR #

2.1.5 Use procedures & directives related to 3.4 1

1. shift staffing and activities Conduct of Operations 2.1.8 Ability to coordinate activities outside 3.6 1 the control room 2.1 Subtotal 2.2.18 Managing maintenance activities while 3.6 1
2. shutdown Equipment Control 2.2.20 Knowledge of the process for 3.3 1 troubleshooting 2.2 2.2 Subtotal 2.3.2 Knowledge of ALARA 2.9 1 3.

Radiation Control 2.3.11 Ability to control radiation release 3.2 1 2.3 Subtotal 2.4.44 Knowledge of Emergency Plan PARs 4.0 1 4.

Emergency 2.4.4 Entry level conditions for AOP/EOP 4.3 1 Procedures /

Plan 2.4 Subtotal K1.07 5.191006 Heat Exchangers and 2.6 1

5. Condensers Generic Fundamentals K1.05 6.192001 Good characteristics of a 2.1* 1 moderator Subtotal Tier 3 Point Total 10 Note:
  • items rated < 2.5 in the KA catalog rate > 2.5 for PVNGS LSROs JTA.

ES-701 LSRO Operating Test Outline Form ES-701-4 Applicant Docket Number: 55- Page 2 of 2 Facility: PVNGS Units 1,2,3 Date of Examination: 12/13/04-12/17/04 Title / Description of Tasks (JPMs) KA / IR Type Evaluation Comment Codes* (S or U) Page Administrative 1 Knowledge of the refueling process. 2.2.27 N, A, T 3.5 JPM: Given an MBA transfer form set to review find 2 errors and the resulting impact on Tech Spec LCO 3.7.17.

2 Knowledge of 10 CFR: 20 and related facility radiation 2.3.1 D control requirements. 3.0 JPM: Determine proper REP and task, contact RP, and enter the RCA. Upon entering your EPD alarms.

3 Knowledge of the Emergency Plan. 2.4.29 N 4.0 JPM: Given a plant condition and references, identify the E-Plan classification.

Systems

1. Fuel Handling Equipment - Lift/Lower a component 034K402 P, A, I using the New Fuel Elevator. 3.3
2. Fuel Handling Equipment - Perform Refueling 034A101 N, A, I, T Machine Load Test and address TRM LCO 3.9.102 3.2
3. Area Radiation Monitors -Verify SFHM bridge ARM 072A201 N, A, I alarm function is operable. 2.9
4. AC Electrical Distribution - Complete the Electrical 062A404 N, I Checklist for the SFHM 2.7 Emergency / Abnormal Plant Evolutions
1. Loss of SDC - Loss of Inventory in the Refuel Pool 025AA102 N, A, I, 3.9 R, T
2. Respond to Irradiated Fuel Damage in the Fuel Bldg 036AA202 N, A, I, R 4.1
3. Loss of a Startup Channel during Refueling 032AA202 P, T 3.9 Type Codes & Criteria:

(A)lternate path ( 2 systems; 1 E/APE)

(C)ontrol room (D)irect from bank ( 7)

(I)n-plant (N)ew or (M)odified from bank including 1(A) ( 1 / section)

(P)revious two exams ( 1 / section)

(R)efueling accident (1)

(T)echnical specification ( 2)

Tier / Randomly Reason for Rejection Selected K/A Group 1 058AK3.01 Not relevant to the LSRO job position 1 058AK3.02 This procedure is used by the CRS not the LSRO 1 062AK3.03 Guidance given in the EOP is not a LSRO function 1 032AK3.03 Not a LSRO function 1 056AK1.01 Not a LSRO function 1 056AK1.03 Not a LSRO function 1 056AK1.04 Not a LSRO function 1 026AA1.01 Not a LSRO function 1 026AA1.02 Not a LSRO function 2 072A2.01 Selected for Operating Test 2 072A2.02 Not a LSRO function 2 072A2.03 Not a LSRO function 2 033A4.01 The RO / CRS monitor this in the Control Room. Not an LSRO function.

2 033A4.02 The RO / CRS monitor this in the Control Room. Not an LSRO function.

2 033A4.03 The RO / CRS monitor this in the Control Room. Not an LSRO function.

2 022A4.01-4.05 The RO / CRS monitor this in the Control Room. Not an LSRO function.

2 076A4.01-4.05 The RO / CRS monitor this in the Control Room. Not an LSRO function.

1 032AK3.02 There is no guidance in either the EOPs or AOPs @ PVNGS for loss of SR NIs. Resampled KA within same system.

2 002A1.11 This is not an LSRO Job Task. KA rejected and resampled within same system.

2 034A1.02 Rejected due to oversampling loss of inventory and resampled within same KA category.