ML19296D169

From kanterella
Revision as of 03:45, 8 November 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
LER 80-018/03L-0:on 800201,during Normal Operation,Core Spray Sys Pipe Break Detector Was Outside of Tech Spec Limits for Nine Days.Caused by Change in Tech Specs.Detector Recalibr to New Tech Spec Value
ML19296D169
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/25/1980
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19296D162 List:
References
LER-80-018-03L, LER-80-18-3L, NUDOCS 8002290429
Download: ML19296D169 (2)


Text

. ...

47 771 i LICENSEE EVENT REPORT (PLEASE PRINT OH TYPE ALL REQUIRED INFORMATION)

CONTROL BLOCK: l i

l l l l l b

lh Imlil8 9lti ly IJ l A lF ll l@l 010l -l 0l O! O! 0l -l 0l 0 0l@l4l1lIl1l1l@l 7 14 1$ LICE NSE NU'.te E H 15 26 LICENSE T YPE Jo S7 LAI 58 l@

LICENSEE CODE CON'T ITITl  %'nN buI L l@l0151010101313 I 31@lb3 i EVENT 2 0l1l8i0 gl0l2]2ls]8]0lg 14 75 HEPORT O ATE da I 8 61 DOCKET NUYUEn e.d OATE EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h

[ol2ll During normal operation Core Spray System pipe break detector was outside l o 3 l of T.S. limits in tabic 3.2-2 for nine days due to a change in T.S. No l

[ o l .1 j l significant hazard existed. See attachment for details. I lo lSI I I o c I I O 7 l l

0 H l 7 ft ') 6L OY$7 E V C AUSE CEM C O*.* P VALVf CCDE CCCE SU C DE C C '.* 5 '. E N T CO D E SU8 CODE S U S C L';., E O ') l1l0l lX l l Zl l 2l 2l 2l El Z 2l l2 20 7 8 9 10 11 12 13 1M IJ

_ M C'.TN'tAl OCCU4PFNCE HEPPDT HEVISION g pp ng t V E'd f Y E A H H t. + di*O COLC ivPL NC.

R E PC R T l 8[ 0l l- l l0 1l 8l l/l l0l3l l I, l l---I Ol

_ 21 12 2J 4

. /t> 21 2d 29 Ju 31 3 .

A C T 10 '.1 FUTURE FFFECT OHu T T n'sN A TT ACu'n N T NP R D.4 PRIMF CO*AP. COYPONENT TAFEN AC TION CN PL A N T '.' E l H C D Hat f p % SUBY1 T T E D FOH'ASUM SUPPLIE 4 UANUFACTUHFH

'

I33 til@l zl@ l3531 @ Lz_J@

%

l of o of ol 3/

LIJ@

43 L1]@ 71@ 171919191 JS 40 42 43 44 41 CAUCE DECCillPTION AND CORRECTIVE AC flONL h) i o l NitC issued T.S. Amendment 48 on 1/23/80. Was received by licer.see on 2/1/80 l 1

,

[ but was effective on date of issue. Itocalibrated detector to new T.S. value. i

, ,

g See attachment f'or details.  ;

4 i :t L I i .i I l 1 8 3 NO Sr .t , *. Po?, ' a OTHEH OT A TUS I C Y DICCOVE HY DESCRIPTION

[iIsl l Ill @ l 0l 91 6l g l xA 44 l lzj@l NA I 7 a 9 19 12 f1 'l i  % 80 ACTIVI T Y CeNTENT ,

H f t. E A *.f D OF HitrAsE A*.10VNT or ACilV! ry LOCAT!GN OF HEEE ASE r, llA IIA

/

1 d 'J Q l2l@l 10 LI 44 l l 4U dJ PE HSONNI L E p r o,us tE s

'

Nip.*I. E n TYPI OCSLDtPTION 1 7 l0 l0 0 l@j Zl@[ f1A l 7 8 9 51 17 13 PEH SON NE L INJUHIE S Ni J pe r a GL LCRIP TION i j; l0 10 l0 lhl NA 1 8 3 it 12 (n-- e . - -* * , r t - e e-* O rr m zl e,Cm.ir I d 'a i

13 PU B LICI TY nA 800s e9 0 Y2? NRC USE ONLY

D

[2lHj 105UF lN l@ Dr l E SC AIPTION tJA II,llIIIlIlll i

j 7 e 2 io ba 69 so NAME OF PREPAPEH W. Verne Childs PH O.J E -

(315) 3'i2-3840

POWER AUT110RITY OF Tile STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT

~

  • DOCKET NO. 50-333 ATTACIIMENT TO LER 80-018/03L-0 Page 1 of 1 During normal operation, the licensee staff received Technical Specification Amendment No. 48 on February 1,1980. Amendment No. 48 was effective upon its day of issue (January 23, 1980). Since the amendment changed the required set point of the Core Spray System Pipe Break Detection from equal to or less than 5.0 psid between the Core Spray Sparger and the Reactor Vessel, to equal to or less than 0.5 psid, the leak detector differential pressure instruments for both Core Spray loops were out of calibration from the date of issue of Amendment No.

48 until the Instruments were recalibrated immediately following receipt of the Amendment on February 1,1980.

As noted above, the instruments were recalibrated to within the limits of Technical Specification tabic 3.2-2, therefore the event did not represent any significant hazard to the public heal +h and safety.

-

With respect to action taken to preclude recurrence, it should be noted that the Authority, in a 1ctter dated October 11, 1978, requested the NRC change its policy of making License Amendments effective on the date of issue except where situations dictate immediate implementation. In view of this earlier request, no additional action to prevent recurrence is required.