ML20024A863

From kanterella
Jump to navigation Jump to search
LER 83-022/03L-0:on 830607,during Performance of Local Leak Rate Testing of Containment Spray,Penetration X-39A Found W/ Leakage That May Exceed Tech Spec Limits.Cause Undetermined. Details Will Be Provided within 30 days.W/830616 Ltr
ML20024A863
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 06/16/1983
From: Keith H, Corbin McNeil
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Allan J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
JAFP-83-0632, JAFP-83-632, LER-83-022-03L, LER-83-22-3L, NUDOCS 8307010060
Download: ML20024A863 (2)


Text

.

Nr.C FORM 366 U.S. NUCLEAR REGULATORY COMMISSION t%77) %

LICENSEE EVENT REPORT CONTROL BLOCK: l 1

l l l l l lh e

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATiON)

Io I i8 l9l Nl UCENSEE F

Y l Jl CODE A l Fl 1 l@l 0 l Ol- l 010 14 15 l 0 l0 l - l0 l 0 l 0l@{4 LICCNSE NUMSER 25 26 l UCENSE 1 l 1l TYPE1l 1]@l40 l

S7 CAT $8 l@

COR*T lolil

? 8 Z "C I60L l@l015l0 61 l 010 l 313 l 31@lo DOCK ET NUMSER 68 69 in EVENT lo 17 OATE I R l a @lo 16REPORT 74 75 l 11DA ATEl e I 80x l@

EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h ,

lo l2l l " Interim Report"--During the performance of Local Leak Rate Testing (LLRT) I g l Containnent Spray, penetration X-39A was found with leakage that may exceed the I g l limit of 0.6La Contained in Technical Specifications 4.7. A.2.b.2. I I

lo Isl I 1016 I I l 10 l 71 i l I

t o ta l i DE CODE SUSC E COMPONENT CODE SLB DE SU E 1o191 I s i o l@ W@ l x l@ I v l A l L l V I E l X l@ [E_j@ [Hj 19 20 F S 9 10 11 12 13 18 SEQUENTI AL 3CCURRENCE REPORT REVISION tgp go EVENTYEAR REPORT NO. CODE TYPE NO.

@ ,ay,g 1813 l l-l Ioi2l2l j. I Ioi3i LL_j 30 L-J 31 LaJ 32

_JI 22 2J 24 26 27 28 29 K N AC ON ON PL NT tET HOURS S8 67 FOR 8. SUP LIE MANUFACTLRER lx 3J l@LILJ@

J4 121@

JS IzlO 36 101010101 31 40 LN_J@

41 LLIO 42 LAJ@

43 Iv I ol si sl@

44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l i l 0 l lCause of the Icakage has not been determined. Additional Local tenk Rnte Tnstint- 1 lilijtremains incomplete at this time. Additional valves mnv rnnnirn vnnnirc no+ ,i p I I i i 21 Iwill be provided 30 davs after the comoletion of thn "loRt" onf,,nting ni,+,no I l

tilal I t i l41 l 80 l

7 8 9

$A S  % POWeiR OTHER STATUS I Y DISCOVERY DESCRIPTION ii Is i lnJ@ LnLoJ_aJ@l n I LaJ@l e. . ~ m ,- I ACTIVITY CO TENT RELEASED OF RELE ASE AMOUNT OF ACTIVITY LOCATION OF RELEASE li l6 l l Zl @ [Zj@l NA l l NA l 7 8 9 10 tt 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE li 171 l0 l 0 l 0l@l '

Zl@lDESCRIPTthN l

PERSONNE'L iNau' RIES NUMBER oESCRiPnONO NA l li la s9l 10 10 l 0l@lt2 7 in 8307010060 830616 8

'fS,S 05 0 o,4"'

CR PT' oTO r AciuTY @

DR ADOCK 05000333 PDR

frlT1 Lzj@l NA 80 l

7 8 9 to PUBLICITY NRC USE ONLY

  • ISSUED ,

g J@ DESCRIPTION 7 3 9 l

10 W. I 68 lIIIlllIIII!l*$.

69 80 NAME OF PREPARER liartford N. Keith PHONE: 315-342-3840 Ext. 230 {

James A. Fit: Patrick

' , .e Nuclear Power Plant PO. Box 41 Lycomag, New York 13093 315 342.3840

  1. > NewYorkPower 4# Authority June 16, 1983 JAFP-83-0632 James M. Allan, Acting Regional Administrator United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, Pa. 19406

REFERENCE:

DOCKET NO. 50-333 Licensee Event , Report: 83-022

Dear Mr. Allan:

We have enclosed the referenced Licensee Event Report in accordance with Section 6.0 of Technical Specifications and USNRC Regulatory Guide 1.16.

If there are any questions concerning this report, please contact Mr. Hartford N. Keith at (315) 342-3840, Extension 230.

Very truly yours,

./ /h m

CORBIN A. McNEILL, JR.

RESIDENT MANAGER CAM /HNK/cm Enclosure CC: USNRC Document Control Desk (1)

! Asst. Director of Operating Reactors, USNRC Directorate of Licensing (1)

INPO Records Center, Atlanta, Georgia (1)

Internal Power Authority Distribution NRC Resident Inspector Document Control Center LER/OR File al 1? 43