ML111801200

From kanterella
Revision as of 06:31, 30 January 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search

E-mail, Request for Additional Information Steam Generator Tube Inspection Report During Refueling Outage 15 (TAC No. ME6244)
ML111801200
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 06/29/2011
From: Gibson L K
Division of Operating Reactor Licensing
To: Stephenson C
Arizona Public Service Co
Gibson, Lauren, NRR/DORL/LPL4, 415-1056
References
TAC ME6244
Download: ML111801200 (1)


Text

From: Gibson, Lauren Sent: Wednesday, June 29, 2011 1:55 PM To: Carl.Stephenson@aps.com Cc: Russell.Stroud@aps.com

Subject:

Questions concerning the Steam Generator Tube Inspection Report for Unit 3 RFO 15 Carl, The NRC staff has a few questions from their review of the Steam Generator Tube Inspection Report for Unit 3 RFO 15, which was submitted on May 5, 2011. Please provide the answers to the questions below via e-mail no later than July 29, 2011.

1. Please confirm that no other secondary side inspections other than FOSAR and the inspection of the patch plate were performed during RFO 15 2. Please provide the cumulative effective full power years on the steam generators at the time of the RFO 14 and RFO 15 outages.

Please contact me if you would like to have a clarification call.

Thank you, Lauren Gibson

Lauren K. Gibson Project Manager, Palo Verde Nuclear Generating Station Division of Operating Reactor Licensing U.S. Nuclear Regulatory Commission (301) 415-1056