ML18193A074

From kanterella
Revision as of 14:16, 11 December 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Palo Verde Units 1, 2 & 3 - Figure 10.4-1, Condenser Air Removal System.
ML18193A074
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 07/12/2018
From:
Arizona Nuclear Power Project
To:
Office of Nuclear Reactor Regulation
References
10.4-1
Download: ML18193A074 (1)


Text

LP TURBINE A LP TURBINE B LP TURBINE C O C PT PT PT CONDENSER A CONDENSER B CONDENSER C VENT POST F ILTER ACTIVATED CHARCOAL FILTER PRE FILTER I L~PC POST FILTER BLOWER MO ISTU R E SEPARATOR POST FILTER ACTIVATED CHARCOAL FILTER PRE FILTER AS POST FILTER BLOWER MOISTURE SEPARATOR AS FROM TGSS 7~HS CR Y-----i 2ND STAGE EJECTOR AFTER CONDENSER INTER CONDENSER AS AS TO CONDENSER C TO CONDENSER C IST STAGE EJECTOR CONDENSER VACUUM PUMPS START PUMPS ON HIGH PRESSURE OF CONDENSER AND OPENS VALVE FROM MAIN STEAM CROSS TIE NOTE: THIS SYSTEM IS NON-SEISMIC CATEGORY I Arizona Nuclear Power Project Palo Verde Nuclear Generating Station Units 1, 2&3 I 0 4 0 7" I I A 5 A 04.4 5 CONDENSER AIR REMOVAL SYSTEM Figure 10.4-1 37