05000275/FIN-2018003-01

From kanterella
Revision as of 00:29, 4 December 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
01
Site: Diablo Canyon Pacific Gas & Electric icon.png
Report IR 05000275/2018003 Section 1R05
Date counted Sep 30, 2018 (2018Q3)
Type: NCV: Green
cornerstone Mitigating Systems
Identified by: NRC identified
Inspection Procedure: IP 71111.05
Inspectors (proximate) C Newport
J Reynoso
R Alexander
L Carson
N Greene
P Hernandez
E Simpson
L Brookhart
C Osterholtz
M Haire
Violation of: 10 CFR 50 Appendix B

10 CFR 50 Appendix B Criterion V

10 CFR 50.59
CCA P.2, Evaluation
INPO aspect PI.2
'