TSTF-11-02, Correction to TSTF-510, Revision 2, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection

From kanterella
Revision as of 23:29, 9 November 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Correction to TSTF-510, Revision 2, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection
ML110610350
Person / Time
Site: Technical Specifications Task Force
Issue date: 03/01/2011
From: Browning R A, Croft W E, Steelman W J, Stringfellow N J
BWR Owners Group, Combustion Engineering, PWR Owners Group, Technical Specifications Task Force, Westinghouse
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
TSTF-11-02, TSTF-510, Rev 2
Download: ML110610350 (74)


Text

11921 Rockville Pike, Suite 100, Rockville, MD 20852 Phone: 301

-984-4400, Fax: 301

-984-7600 Administration by EXCEL Services Corporation TECHNICAL SPECIFICATIONS TASK FORCE A JOINT OWNERS GROUP ACTIVITY TSTF March 1, 2011 TSTF-1 1-0 2 PROJ0753

Attn: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555

-0001

SUBJECT:

Correction to TSTF

-510, Revision 2, "Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection

"

Dear Sir or Madam:

Revision 2 of TSTF

-510, "Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection

," was submitted to the NRC on October 11, 2010.

We have been informed that Page 1 of the justification was inadvertently omitted from the submitted Traveler. Enclosed is a complete copy of TSTF

-510, Revision 2.

Should you have any questions, please do not hesitate to contact us.

Norman J. Stringfellow (PWROG/W) Roy A. Browning (BWROG)

William J. Steelman (PWROG/CE)

Wend y E. Croft (PWROG/B&W)

Enclosure cc: Robert Elliott, Technical Specifications Branch, NRC Michelle Honcharik, Licensing Processes Branch, NRC

TSTF-510, Rev. 2WOG-195, Rev. 0NUREGs Affected:Revision to Steam Generator Program Inspection Frequencies and Tube Sample SelectionTechnical Specification Task Force Improved Standard Technical Specifications Change Traveler14301431143214331434Classification1) Technical ChangeRecommended for CLIIP?:YesCorrection or Improvement:Im provementNRC Fee Status:ExemptBenefit: Allows Less Stringent Testing See attached.Revision History OG Revision 0Revision Status:ClosedOriginal IssueRevision Descri ption:Revision Proposed by:NEI SGTFOwners Group Review InformationDate Originated by OG:27-Feb-09Owners Group Comments(No Comments)Date:13-Mar-08Owners Group Resolution:ApprovedTSTF Review InformationTSTF Received Date:15-Mar-08Date Distributed for Review15-Mar-08TSTF Comments:(No Comments)Date:26-Mar-09TSTF Resolution:ApprovedOG Review Completed:BWOG CEOGWOG BWROGNRC Review InformationNRC Received Date:26-Mar-09Fee exemption letter dated 7/20/09.The NRC provided an RAI by e-mail on 2/4/2010.Superceded by RevisionNRC Comments:Final Resolution:TSTF Revision 1Revision Status:Closed11-Oct-10Traveler Rev. 3. Copyright(C) 2010, EXCEL Services Corporation. Use by EXCEL Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.

TSTF-510, Rev. 2WOG-195, Rev. 0TSTF Revision 1Revision Status:ClosedTSTF-510 is revised to reflect the responses to an RAI provided by the NRC on February 4, 2010.1. Pages 5 and Section 2 of the justification are revised to clarify that the 20% minimum SG tube sample size appears in the EPRI guideline documents, not the Technical Specifications.2. Page 16 of the justification is revised to eliminate the discussion of changes made to SG tubes under 10 CFR 50.59.

3. TS 5.5.9.c and the Steam Generator Tube Integrity Specification are revised to state "alternate tube plugging [or repair] criteria" instead of "alternate tube repair criteria."
4. The Revision 0 proposed change to replace "flaw" and "indication" with "degradation" is removed in Revision 1.
5. TS 5.5.9.d.2 is revised to clarify that the inspection frequency is a minimum requirement.
6. TS 5.5.9.d.2 for Alloy 600 mill annealed tubing is revised to make clear that the inspection interval is 60 EFPM.7. TS 5.5.9.d.2 for all material types is revised to clarify the treatment of new degradation types at unexamined locations.8. TS 5.5.9.d.2 for Alloy 600 mill annealed tubing is revised to reorder the discussion to improve clarity.A new change is added to TS 5.5.9.d.3 to clarify which SGs are to be tested when a crack indication is found.

A new change is made to consistently refer to "inspection periods" instead of sometimes using the term "inspection intervals."Revision Descri ption:Revision Proposed by:NRCOwners Group Review InformationDate Originated by OG:30-Apr-10Owners Group Comments(No Comments)Date:14-May-10Owners Group Resolution:ApprovedTSTF Review InformationTSTF Received Date:29-Apr-10Date Distributed for Review15-Jun-10TSTF Comments:(No Comments)Date:29-Jun-10TSTF Resolution:ApprovedOG Review Completed:BWOG CEOGWOG BWROGNRC Review InformationNRC Received Date:29-Jun-1011-Oct-10Traveler Rev. 3. Copyright(C) 2010, EXCEL Services Corporation. Use by EXCEL Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.

TSTF-510, Rev. 2WOG-195, Rev. 0 Affected Technical SpecificationsTSTF Revision 1Revision Status:ClosedAt a public meeting between the NRC and the Nuclear Energy Institute (NEI) Steam Generator Task Force (SGTF) held on August 12, 2010, the NRC disagreed with the change in Revision 1 to replace the term "interval" with "period." The NRC believes the terms "interval" and "period" to mean the "interval between steam generator inspections" and "the overall inspection period", respectively.12-Aug-10NRC Requests Changes: TSTF Will ReviseNRC Comments:Final Resolution:Final Resolution Date:TSTF Revision 2Revision Status:ActiveAt a public meeting between the NRC and the Nuclear Energy Institute (NEI) Steam Generator Task Force (SGTF) held on August 12, 2010, the NRC provided the following comments on TSTF-510, Rev. 1. In Revision 2, the TSTF-510 justification, Technical Specifications, and Bases are revised to use the terms "interval" and "period" to mean the "interval between steam generator inspections" and "the overall inspection period" respectively. A description of the terms is added to the justification. The only change to the TS is in paragrph d of the Steam Generator Program, in which the term "periods" is replaced with "intervals."Revision Descri ption:Revision Proposed by:NRCOwners Group Review InformationDate Originated by OG:31-Aug-10Owners Group Comments(No Comments)Date:22-Sep-10Owners Group Resolution:ApprovedTSTF Review InformationTSTF Received Date:22-Sep-10Date Distributed for Review22-Sep-10TSTF Comments:(No Comments)Date:11-Oct-10TSTF Resolution:ApprovedOG Review Completed:BWOG CEOGWOG BWROGNRC Review InformationNRC Received Date:11-Oct-10 5.5.9Steam Generator (SG) Program11-Oct-10Traveler Rev. 3. Copyright(C) 2010, EXCEL Services Corporation. Use by EXCEL Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.

TSTF-510, Rev. 2WOG-195, Rev. 0 5.6.7Steam Generator Tube Inspection ReportLCO 3.4.17NUREG(s)- 1430 OnlySG Tube IntegrityLCO 3.4.17 BasesNUREG(s)- 1430 OnlySG Tube IntegrityAction 3.4.17.ANUREG(s)- 1430 OnlySG Tube IntegrityAction 3.4.17.A BasesNUREG(s)- 1430 OnlySG Tube IntegritySR 3.4.17.1 BasesNUREG(s)- 1430 OnlySG Tube IntegritySR 3.4.17.2NUREG(s)- 1430 OnlySG Tube IntegritySR 3.4.17.2 BasesNUREG(s)- 1430 OnlySG Tube IntegrityLCO 3.4.20NUREG(s)- 1431 OnlySG Tube IntegrityLCO 3.4.20 BasesNUREG(s)- 1431 OnlySG Tube IntegrityAction 3.4.20.ANUREG(s)- 1431 OnlySG Tube IntegrityAction 3.4.20.A BasesNUREG(s)- 1431 OnlySG Tube IntegritySR 3.4.20.1 BasesNUREG(s)- 1431 OnlySG Tube IntegritySR 3.4.20.2NUREG(s)- 1431 OnlySG Tube IntegritySR 3.4.20.2 BasesNUREG(s)- 1431 OnlySG Tube IntegrityLCO 3.4.18NUREG(s)- 1432 OnlySG Tube IntegrityLCO 3.4.18 BasesNUREG(s)- 1432 OnlySG Tube IntegrityAction 3.4.18.ANUREG(s)- 1432 OnlySG Tube IntegrityAction 3.4.18.A BasesNUREG(s)- 1432 OnlySG Tube IntegritySR 3.4.18.1 BasesNUREG(s)- 1432 OnlySG Tube IntegritySR 3.4.18.2NUREG(s)- 1432 OnlySG Tube IntegritySR 3.4.18.2 BasesNUREG(s)- 1432 OnlySG Tube Integrity11-Oct-10Traveler Rev. 3. Copyright(C) 2010, EXCEL Services Corporation. Use by EXCEL Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.

TSTF-510, Rev. 2 Page 1 of 20

1.0 DESCRIPTION

The proposed change revises the Improved Standard Technical Specification (ISTS), NUREGs 1430, 1431, and 1432, Specif ication 5.5.9, "Steam Generator (SG) Program," 5.6.7, "Steam Generator Tube Inspecti on Report," and the St eam Generator Tube Integrity specification, (LCO 3.4.17, LCO 3.4.20, and LCO 3.4.18 in ISTS NUREG-1430, -1431, and -1432, respectively) The proposed changes are necessary to address implementation issues associated with t he inspection periods, and address other administrative changes and clarifications.

2.0 PROPOSED

CHANGE The proposed change will revise Technical Specif ication 5.5.9, "St eam Generator (SG)

Program."

An editorial correction is made to the intr oductory paragraph. The last sentence is revised from "In addition, the Steam Gener ator Program shall include the following provisions" to "In addition, the Steam Gener ator Program shall in clude the following." The subsequent paragraphs start with "Provisions for -" and stating "provisions" in the introductory paragraph is duplicative.

An editorial correction is made to Paragraph 5.5.9.b.1. The clos ing parenthesis is misplaced. It currently states "All in-s ervice steam generator tubes shall retain structural integrity over t he full range of normal operating conditions (including startup, operation in the power range, hot standby, a nd cool down, and all anticipated transients included in the design specification) and design basis acci dents." This inappropriately includes anticipated transient s in the description of norma l operating conditions. The sentence is revised to, "All in-service steam generator tubes shall retain structural integrity over the full range of normal operating conditions (inc luding startup, operation in the power range, hot standby, and cool do wn), all anticipated transients included in the design specification, and design basis accidents." An editorial correction is made to add a mi ssing closing bracket to the end of Paragraph 5.5.9.b.2.

Clarifications are made to Paragraph 5.5.9.c.

The title is revised from "Provisions for SG tube repair criteria" to "Provisions for SG tube plugging [or repa ir] criteria" to be consistent with the treatment of SG tube re pair throughout Specific ation 5.5.9. All references in Paragraph 5.

5.9.c to "SG tube repair crit eria" are changed to "SG tube plugging [or repair] criteria. To be consist ent with this change, references to the "tube repair criteria" are revised to "tube plugging

[or repair] criteria in the Steam Generator (SG) Tube Integrity Specification (LCO 3.4.17 in NUREG-1430, LCO 3.4.20 in NUREG-1431, and LCO 3.4.18 in NUREG-1432) and the associated Bases.

Clarifications are made to Paragraph 5.5.9.d. Reference to "tube repair criteria" is revised to "tube plugging [or repair] criteria" to be consist ent with the treatment of SG tube repair throughout Specificat ion 5.5.9. The term "assessment of degradation" is replaced with "degradation assessment" to be consistent with the terminology used in TSTF-510, Rev. 2 Page 2 of 20 the industry program documents.

Paragraph 5.5.9.d.1 is revised from "Inspect 100% of the t ubes in each SG during the first refueling outage following SG replacement" to "Inspect 100% of the tubes in each SG during the first refueling outage following SG installati on." This wording change will allow the Steam Generator Program to appl y to both existing plants and new plants. The proposed change revises TS 5.

5.9.d.2 within the Steam G enerator (SG) Program to modify the frequency of verification of SG tube integrity and SG tube sample selection to reduce implementation issues experienced with the current specification. The revised specification is consistent with the exis ting specification in that it continues to be based on SG tube material type, age, c ondition and cycle length, and continues to address the time dependence of degradation and prevent front end or back end loading

of inspections. In addition, the maximum interval allowed between inspections is the same as in the current Technical Specification.

Paragraph 5.5.9.d.3 refers to "next inspection for each SG - shall not exceed 24 effective full power months or one refueling outage (whichever is less)." An editorial change is made to the parenthetical statement in order to clarify the intent. It is revised to "(whichever results in more frequent inspections)". Paragraph 5.5.9.d.3 is also revised to clarify the SG inspection requirements when crack indications are found.

Specification 5.6.7, "Steam Generator Tube Inspection Report," is revised to change the reporting requirements. Paragraph f is revised to require reporting the effective plugging

percentage. Optional paragraph h, which required reportin g the effective plugging percentage, is deleted. The word "active" was removed from 5.6.7.b and e to be consistent with Spec ification 5.5.9.

Technical Specification 5.5.

9 and the Bases of the Stea m Generator Tube Integrity Specification use the terms "interval" and "p eriod" when referring to the steam generator inspections. For consistency, the term "per iod" is used when referring to the overall inspection period and the term "interval" is used when referring to the time between steam generator inspections.

3.0 BACKGROUND

The SG tubes in pressurized water reacto rs have a number of important safety functions. Steam generator tube s are an integral part of t he reactor coolant pressure boundary (RCPB) and, as such, are relied on to maintain the primary system's pressure and inventory. As part of the RC PB, the SG tubes are unique in that they act as a heat transfer surface between t he primary and secondary systems to remove heat from the primary system. In addition, the SG tubes is olate the radioactive fission products in the primary coolant from the secondary system.

Steam generator tube int egrity is necessary in order to satisfy the tubing's safety functions. Maintaining tube integrity ensures that the t ubes are capable of TSTF-510, Rev. 2 Page 3 of 20 performing their intended safety functions consistent with the plant licensing basis, including applicable r egulatory requirements.

Concerns relating to the integr ity of the tubing stem from the fact that the SG tubing is subject to a variety of degradation mechanisms. St eam generator tubes have experienced tube degradation related to co rrosion phenomena, such as wastage, pitting, intergranular attack, and stress corrosion cracking, along with other mechanically induced phenomena such as wear. These degradation mechanisms can impair tube integrity if they are not managed effectively.

When the degradat ion of the tube wall reaches a prescribed criterion for action, the tube is considered defective and corrective action is taken. Note that not all plants have approved repair techniques.

Therefore, references to "r epair" are bracketed in the pr oposed TS changes. Plants without approved repair techniques should remove the bracketed references to repair

and make editorial changes to the text as needed for proper English usage.

The industry, through the Electric Power Research Institute (EPR I) Steam Generator Management Program (SGMP), has previously developed a generic approach to improving SG performance referred to as "Steam Generator D egradation Specific Management" (SGDSM). Under this approach , different methods of inspection and different repair criteria ma y be developed for different types of degradation. A degradation specific approach to managing SG tube integrit y has several important benefits. These include:

  • increased scope and improved met hods for SG inspection,
  • industry incentive to continue to improve inspection methods, and
  • development of plugging and repair criteria based on appropriate NDE parameters.

As a result, the assurance of SG tube integrity is improved. Over the course of this effort, the SGMP has developed a series of EPRI guidelines that define the elements of a successful SG Program. These guidelines include:

  • "PWR Primary-to-Secondary Lea k Guideline" (Ref. 4),
  • "Primary Water Chemistry Guideline" (Ref. 5), and
  • "Secondary Water Chemistry Guideline" (Ref. 6).

TSTF-510, Rev. 2 Page 4 of 20 These EPRI Guidelines, along with NEI 97-06 (Ref. 7), tie the ent ire Steam Generator Program together, while defin ing a comprehensive, performance based approach to managing SG performance. In parallel with the industry efforts, t he NRC pursued resolution of SG performance issues. In December of 1998, the NRC Staff acknowledged that the Steam Generator Program described by NEI 97-06 (Ref. 7) and its referenced EPRI Guidelines provides an acceptable starting point to use in the resolution of differences between it and the staff's proposed Generic Letter and draft Regulatory Guide (DG-1074). Since then the industry and the NRC have participated in a se ries of meetings to resolve the differences and develop the regulatory framework necessary to implement a comprehensive Steam G enerator Program.

As a result of these interactions, the r egulatory framework was recently revised via Reference 8 to accommodate degradation specific management and to address the issues of regulatory stability, resource expenditure, use of state-of-the-art inservice inspection techniques, repair criteria, and enf orceability. The NRC Staff has stated that an integrated approach for addressing SG tube integrity is essential and that materials, systems, and radiological issues that pertain to tube integrity need to be considered in the development of the new regulatory framework. The NRC Staff approved Reference 8 and it was posted for adoption by licensees in the NRC Federal Register Notice of Availability published on May 6, 2005 (70 FR 24126). All US PWR licensees have now

adopted this approach.

4.0 TECHNICAL

ANALYSIS The proposed changes do not affect the design of the SGs, their method of operation, the operational leakage limi t, the accident analyses or primary coolant chemistry controls. The primary coolant activity limit and its assumptions are not affected by the proposed changes to the standard technical specifications. The proposed changes are an improvement to the existing SG inspection requirements and continue to provide assurance that the plant licens ing basis will be maintained between SG inspections. The proposed changes contain a number of editorial corrections, changes, and clarifications intended to improve internal consistency, consistency with the implementing industry documents, and usability without changing t he intent of the requirements.

The proposed changes to TS 5.5.9.d.2 are mo re effective in managing the frequency of verification of tube integrity and sample selection than those required by current technical specifications. As a resul t, the proposed changes will not reduce the assurance of the function and integrity of SG tubes.

The table below and associated sections des cribe in detail the proposed changes and provide the technical justification .

TSTF-510, Rev. 2 Page 5 of 20 Condition or Requirement Current Licensing

Basis Location - Proposed Change Sec.Frequency of

verification of

SG tube integrity SG Tube Integrity SR 3.4.17.1 (NUREG-1430),

SR 3.4.20.1 (NUREG-

1431), and SR 3.4.18.1 (NUREG-1432) The

Frequency is in accordance with TS

5.5.9, Steam Generator Program. Frequency is

dependent on tubing

material and the previous

inspection results and

the anticipated defect

growth rate. The Steam

Generator Program establishes maximum inspection periods.

The SG Tube Integrity Surveillance Requirements are unchanged.

Steam Generator Program TS 5.5.9.d.2 for Alloy 600TT and Alloy

690TT tubing, (1) Inspection period

midpoint requirement is deleted, (2)

the 2 nd and subsequent inspection periods lengths are lengthened

marginally and (3) for all tube

material types, a provision is added to allow extending each inspection

period by up to three effective full

power months.

For all tubing types, a provision is added to clarify prorating of new

sample plans. Frequency remains dependent on tubing material and the previous inspection results and the

anticipated defect growth rate. The

maximum inspection periods are

unchanged.

A conforming change is made to the parenthetical expression "(whichever

is less)" in TS 5.5.9.d.3 for consistency with changes proposed

for TS 5.5.9.d.2.

1 Tube sample

selection Implementing procedures required by the Steam

Generator Program -

Dependent on a

preoutage evaluation of actual degradation

locations and mechanisms, and

operating experience -

minimum 20% of all

tubes as required by

Reference 1.

Implementing procedures required by

the Steam Generat or Program - Dependent on a pre-outage

evaluation of actual degradation

locations and mechanisms, and

operating experience - minimum

20% of all tubes as required by

Reference 1. Adds provisions to

increase minimum sample size based

on the number of inspections

scheduled in each inspection period

for 600TT and 690TT tubing types.

2 TSTF-510, Rev. 2 Page 6 of 20 Condition or Requirement Current Licensing

Basis Location - Proposed Change Sec.Steam Generator

Tube Inspection

Report TS 5.6.7 - 180 days after the initial entry into MODE 4 after performing

a SG inspection The term "active" is removed from 5.6.7.b and 5.6.7.e as this term is not defined in the specifications.

TS 5.6.7.h is combined with TS 5.6.7.f and, theref ore, 5.6.7.h is deleted. TS 5.6.7.i is changed to TS 5.6.7.h as a conforming change.

3 Section 1: Frequency of Verifi cation of SG Tube Integrity Minor wording changes are made to the surveillance Frequency in Technical Specification 5.5.9.d.

2 as detailed in the discussion below. The maximum surveillance interval between inspections in the existing Steam Generator Tube Integrity specification, which is spec ified in the Steam Generator Program, is unchanged. The interval between inspections is dependent on tubing material and whether any

degradation is found. The interval between inspections is limited by existing and potential degradation mechanisms and their anticipated growth rate.

The current Technical Specif ication 5.5.9.d.2 establishes sequential periods for inspection of steam generator tubes. T he length of each inspection period is based on tubing material type and the age of the steam generators. Materi als that are more susceptible to corrosion degradation have s horter inspection periods in which to complete all inspections. The inspection period length for Alloy 600 mill annealed

tubing (600MA) is fixed at 60 effective full power months (EFPM) because this material is more susceptible to degradation than other materials. The inspection period length for Alloy 600 thermally treated tubing (600TT) and Alloy 690 thermally treated tubing (690TT) tubing are longer early in the life of the steam generators and shorten as the steam generators age and become more su sceptible to degradation. These fundamental aspects of the current specification are retained. Within each inspection period for 600 TT tubing and 690TT tubing, the current specification establishes inspection require ments for the midpoint and end point of each period such that 50% of the tubes are inspected by the refueling outage nearest the midpoint, and the remaining 50% is inspected by the refueling outage nearest the end point. After all US PWR licensees amended their Tec hnical Specifications to incorporate the current specifications, plants with 600 TT and 690TT tubing have or will experience implementation issues associated with the cu rrent TS 5.5.9.d.2.

Generally, these issues interfere with a plant's ability to operate for the maximum inspection inverval allowed by the specific ation even when no degradati on is present. Sampling requirements for the midpoint and end point of each inspection period, and TSTF-510, Rev. 2 Page 7 of 20 requirements for addition of new sample plans after the start of a inspection period are not well defined (this issue also applies to plants with 600MA tubing) and frequently require a plant to adjust the si ze of the inspection sample to meet these requirements.

The current TS 5.5.9.d.2 for plants with 600MA tubing states: "Inspect 100% of the tubes at sequentia l periods of 60 effective full power months. The first sequential period shall be considered to begin after the first inservice inspection of the SGs.

No SG shall operat e for more than 24 effective full power months or one refueling outage (whichever is less) without being inspected." The current TS 5.5.9.d.2 for plants with 600TT tubing states: "Inspect 100% of the tubes at sequential periods of 120, 90, and, thereafter, 60 effective full power months. The first sequential period shall be considered to begin after the first in service inspection of the SGs. In addition, inspect 50% of the tubes by the refueling outage nearest the midpoint of the period and the remaining 50% by the refueling outage

nearest the end of the period. No SG shall operate for more than 48 effective full power months or two re fueling outages (whichever is less)

without being inspected." The current TS 5.5.9.d.2 for plants with 690TT tubing states: "Inspect 100% of the tubes at sequent ial periods of 144, 108, 72, and, thereafter, 60 effective full power mont hs. The first sequential period shall be considered to begin after the first in service inspection of the SGs. In addition, inspect 50% of the tubes by the refueling outage nearest the

midpoint of the period and the remaining 50% by the refueling outage

nearest the end of the period. No SG shall operate for more than 72 effective full power months or three re fueling outages (whichever is less) without being inspected." Specifically, the implement ation issues with the curr ent TS 5.5.9.d.2 are:

  • As originally envisioned by the Indus try, the current wo rding would provide flexibility in completion of inspection requirements by the midpoint and end point of the period such that it would permit us ing a refueling outage that occurs after the midpoint or end point provided it was cl oser than the prior refueling outage.

NRC Staff, however, determined in Referenc e 9 that the specification requires

completion of all inspections within the inspection period and does not permit completion of inspections at a refue ling outage after the end point. This determination resulted in a significant lo ss of flexibility in scheduling inspections to meet the end point requirement.

  • As plants with 600TT and 690TT tubing age, they progress from longer to shorter inspection periods. In addition, each period has inspection requirements TSTF-510, Rev. 2 Page 8 of 20 associated with the midpoint and end poin
t. It has been recognized that the shorter inspection periods in combination with the midpoint and end point requirements prevent 600TT and 690TT plant s from operating for the maximum interval between inspections permitted by the specification, even if no degradation has been detected.

The limitation is most severe for 690TT plants with 24 month fuel cycles during the 60-mont h inspection periods. For example:

A 690TT plant with no degradation would be allowed to operate for 72 effective full power months or three refueling outages (whichever is less) between inspections during the longer inspection periods, but can operate only one cycle between inspections during the 60EFPM inspection period because there are only 30 EFPM before the midpoint or end point is reached.

  • Sampling requirements for the midpoint and end point of each inspection period are not well defined and fr equently require a plant to adjust the size of the inspection sample to meet these require ments. For example, a plant may have two inspections scheduled in the first hal f of the inspection period and only one inspection scheduled in the second half of the inspection period. The plant can select a sample size of 25% for each inspection in the first half to meet the midpoint requirement, but must increase the sample size to 50% in the second half to meet the end point requirement when it would be preferable to maintain a set sample size of 33.3% at each ins pection throughout the inspection period.

The current specification, however, r equires the sample size for the only inspection scheduled in the later half of the inspection period to be adjusted to at least 50%.

  • The current specification does not cl arify sampling requirements when a new sampling plan is added to the inspection scope after the start of an inspection period (this issue also applies to plants with 600MA tubing). For example: if a licensee adds a new sample plan during their last inspection in a given inspection

period, and the licensee has already comp leted two prior inspections during the inspection period, it is unclear if the licensee must sample 100%

of the tubing to meet the end point requirement or if the sample can be prorated in some manner. The NRC Staff has determined in Reference 9 that prorating of new sample plans would be acceptable. T hus, it is appropriate to include such provisions in the Steam Generator Program.

To address these implementation issues, t he following changes to TS 5.5.9.d.2 are proposed: 1. For 600MA tubing, a provision is added to clarify prorating for inspection of new degradation types or locations. The inspection period length, inspection requirements and maximum inspection interval between inspections are unchanged. A provision is added to allow extending each inspection period by up to three EFPM to resolve the inflex ible nature of a fixed end point in the

current specification, and a pr ovision is added to clarify pr orating for inspection of new degradation types or locations. T hese provisions are discussed in detail TSTF-510, Rev. 2 Page 9 of 20 below. The maximum intervals betw een inspections for 600MA tubing are unchanged.

Also for 600MA tubing, minor wording cha nges are made for greater clarity as follows:

  • The phrase "After the first refueling outage following SG installation " is added to the beginning of t he specification to clarify the timing of the applicability.
  • The phrase "every 24 effective full power months" is changed to "at least every 24 effective full power months" for greater clarity.
  • The parenthetical expression "(whichever is less)" is changed to

"(whichever results in more frequent inspections)" since effective full power months reflect an operating time, whereas one refueling outage reflects an event.

  • The phrase "one refueling outage" is changed to "at least every refueling outage" for greater clarity. 2. For 600TT and 690TT tubing, the inspection period midpoint requirement is deleted. The length of the second and subsequent inspection periods is increased marginally for consistency with typical fuel cycle lengths and, thus, better accommodates scheduling of inspections. A provision is added to allow extending each inspection period by up to three EFPM to resolve the inflexible nature of a fixed end point in the current specification, and a provision is added to clarify prorating for inspection of new degradation types or locations. The maximum intervals between inspec tions for 600TT and 690TT tubing are unchanged.

Also, minor wording changes are made for greater clarity as follows:

  • For 600TT and 690TT tubing the phrase "A fter the first refueling outage following SG installation" is added to the beginning of the specification to clarify the timing of the applicability.
  • For 600TT tubing, the phrase "every 48 effective full power months" is changed to "at least every 48 effective full power months" for greater clarity.
  • For 690TT tubing, the phrase "every 72 effective full power months" is changed to "at least every 72 effective full power months" for greater

clarity.

  • For 600TT and 690TT tubing the parenthetical expression "(whichever is less)" is changed to "(whichever results in more frequent inspections)"

TSTF-510, Rev. 2 Page 10 of 20 since effective full power months reflect an operating time, whereas one refueling outage reflects an event.

A conforming change is also made to TS 5.5.9.d.3 to modify the parenthetical expression "(whichever is less)" is changed to "(whichever results in more frequent inspections)".

  • For 600TT tubing the phrase "or two refueling outages" is changed to "or at least every other refueling outage" for greater clarity.
  • For 690TT tubing the phrase "or thr ee refueling outages" is changed to "or at least every third refueling outage" for greater clarity.

A provision is added to TS 5.5.9.d.2 [600MA, 600TT and 690TT] to clarify prorating of inspections for new degradation types or locations for each of the tube material types. It requires that the fraction of locations to be inspected for new potential degradation types or locations at the end of the inspecti on period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradati on could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. This is expressed in the fo llowing equation:

I f I s / I t Where: I f = the prorated fraction of tubes/locations scheduled to be inspected by the end of the inspection period.

I s = the number of SG inspection out ages scheduled to be performed in the inspection period subsequent to the determination that a new degradation type may occur or that new locations may be susceptible to degradation.

I t = the total number of SG inspection outages scheduled to be performed in the inspection period.

For example, a licensee has comp leted one of three inspections (I t) in a given inspection period. The licensee's degradat ion assessment indicates that tubes/new locations may be susceptible to degradati on at the next scheduled inspection and, therefore, is adding tubes/new locations to the two remaining inspections (I s) in that inspection period. Therefore, at the end of the inspection period (i.e., when the two remaining inspections in that inspecti on period are completed), the licensee must ensure that the fraction of tubes/locations inspected is equal to at least 2/3 of the total number of tubes/new locations susceptible.

Thus, in each of the two inspections subsequent to the determination that a new degradation type may o ccur or that new locations may be susceptible to degradation, the licensee would inspect at least 1/3 of

the tubes/new locations.

Specification 5.5.9.

d.2 [600TT and 690TT] is revis ed to lengthen some inspection TSTF-510, Rev. 2 Page 11 of 20 periods in order to better align the inspec tions with fuel cycle length. For 600TT tube material, the inspection periods are changed from 120 EFPM, 90 EFPM, and 60 EFPM to 120 EFPM, 96 EFPM, and 72 EFPM. For 690TT tube material, the inspection periods are changed from 144 EFPM, 108 EFPM, 72 EFPM, and 60 EFPM to 144 EFPM, 120 EFPM, 96 EFPM, and 72 EFPM.

The maximum interval between inspections (48 EFPM for 600TT and 72 EFPM for 690TT) is unchanged, so the proposed increase in the total length of each inspection period does not increase the maximum time of the surveill ance frequency. The interval between inspections must be supported by an assessment that concludes tube integrity will be maintained for the period of planned operations. Industry guidanc e requires this assessment to consider operating experience of ot her units and the potential need for more frequent inspections. This guidance also requires timely reporting of significant operating experience, including potentially new degradation mechanisms, to EPRI issue groups

for consideration of generic action among members. Thus, incorporation of relevant operating experience is considered as an industry approach and is less subject to isolation of individual experiences. The asse ssment must be reviewed at each refueling outage regardless of whether a SG inspection is planned. If this assessment concludes that tube integrity cannot be ensured for the maximum interval between inspections, more frequent inspections are required. In addi tion, if crack-like indications are found in any SG, the interval to the nex t inspection is limited by TS 5.5.9.d.3 to 24 effective full power months or one refueling outage (whichever results in more frequent inspections).

The specification would allo w a plant with cracking to return to a longer inspection frequency if cracking was not detected in a subsequent inspection provided it is supported with adequate justification in the degradation and operational assessments. The potential that the total number of SG inspections completed during a given inspection period may be less is offset by the addition of provisions to increase the minimum sample size at each inspection to ensure that 100% of tubes are inspected. This justification also supports the provis ion to allow a 3 effective full power month extension of the inspection period to incl ude a SG inspection outage in an inspection period. Thus, the proposed increase in the total length of each inspection period for 600TT and 690TT tubing does not reduc e or adversely impact the integrity of SG tubing. Taken in total, the proposed changes provide an acceptable margin of safety compared

to the current requirements because the maximum allowable interval between inspections is the same as the current technical specifications. The minimum sample size at each inspection is also the same as that required by the SG Program (20 percent of the tubes in each SG). A provision is added to clarify prorating of new sample plans. A provision is added to allo w extending each inspec tion period by up to three effective full power months to resolve t he inflexible nature of a fixed end point in the current specification.

A requirement is added to increas e the minimum sample size based on the number of inspections performed in each inspection period. For example; if only one inspection is performed during a given inspection period, the minimum sample size would be 100% of the tubes in each steam generator, thus providing added assurance that any degradation within the SGs will be det ected and accounted for in establishing the inspection period.

TSTF-510, Rev. 2 Page 12 of 20 The proposed maximum inspection periods are based on the historical performance of advanced SG tubing materials. Reference 10 shows that the performance of Alloy 600TT and 690TT is significantly better than t he performance of 600MA tubing. There

have been relatively few instances of crack-like indications reported in 600TT tubes in U.S. SGs. To date, there are no known instances of cracking in 690TT tubes, sleeves, or plugs in either the U.S.

or international SGs.

TS 5.5.9.d.2 for the 600TT and 690TT includes a Reviewer's Note that states that licensees may elect to retain historical and existing inspection period lengths in order to

not revise those inspection periods. For example, a 600TT plant at the end of the second SG inspection period may elect to reta in the 90 effective full power month length of the second inspection period instead of the revised 96 effective full power month length so that the second period may be completed under the current inspection plan. The proposed TS 5.5.9.d.

2 for 600MA tubing is: "After the first refueling outage following SG installation, inspect each steam generator at least every 24 effective fu ll power months or at least every refueling outage (whichever results in more frequent inspections). In addition, inspect 100% of the tubes at sequential periods of 60 effective full power months beginning after the first refueling outage inspection following SG installation. Each 60 effective full power month inspection period may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins

at the conclusion of the included SG inspection outage. If a degradation assessment indicates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locati ons to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period afte r the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period." The proposed TS 5.5.9.d.

2 for 600TT tubing is: "After the first refueling outage following SG installation, inspect each SG at least every 48 effective full power months or at least every other refueling outage (whichever results in more frequent inspections). In addition, the minimum number of tubes inspected at each scheduled inspection shall be the number of tubes in all SGs divided by the num ber of SG inspection outages scheduled in each inspection per iod as defined in a, b, and c below. If a degradation assessment i ndicates the potential for a type of TSTF-510, Rev. 2 Page 13 of 20 degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspecti on technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degr adation at this location at the end of the inspection period shall be no less t han the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period.

Each inspection period defined below may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage.



Re viewer's Note ----------



A licensee may elect to retain historical and existing inspection period

lengths in order to not revi se those inspection periods. ---------------------------------------------------------------------------------


a) After the first refueling outage follo wing SG installation, inspect 100% of the tubes during the next 120 effective full power months. This constitutes the first inspection period; b) During the next 96 effective full power months, inspect 100% of the tubes.

This constitutes the second inspection period; and c) During the remaining life of the SGs, inspect 100% of the tubes every 72 effective full power months. This c onstitutes the third and subsequent inspection periods." The proposed TS 5.5.9.d.

2 for 690TT tubing is: "After the first refueling outage following SG installation, inspect each SG at

least every 72 effective full power months or at least every third refueling outage (whichever results in more frequent inspections). In addition, the minimum number of tubes inspected at each scheduled inspection shall be the number of tubes in all SGs divided by the num ber of SG inspection outages scheduled in each inspection per iod as defined in a, b, c and d below. If a degradation assessment indi cates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspecti on technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degr adation at this location at the end of the inspection period shall be no less t han the ratio of the number of times TSTF-510, Rev. 2 Page 14 of 20 the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period.

Each inspection period defined below may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage.



Re viewer's Note ----------



A licensee may elect to retain historical and existing inspection period

lengths in order to not revi se those inspection periods. ---------------------------------------------------------------------------------


a) After the first refueling outage follo wing SG installation, inspect 100% of the tubes during the next 144 effective full power months. This constitutes the first inspection period; b) During the next 120 effective full pow er months, inspect 100% of the tubes. This constitutes the second inspection period; c) During the next 96 effective full power months, inspect 100% of the tubes. This constitutes the third inspection period; and d) During the remaining life of the SG s, inspect 100% of the tubes every 72 effective full power months. This constitutes the fourth and subsequent

inspection periods." The current TS 5.

5.9.d.3 states: "If crack indications are found in any SG tube, then the next inspection for each SG for the degradation mechanism that caused the crack indication shall not exceed 24 effective full power months or one refueling outage (whichever is

less). If definitive information, such as from examination of a pulled tube, diagnostic non-destructive testing, or engineering evaluation indicates that a crack-like indication is not associated with a crack(s), then the indication need not be treated as a crack." For conformance with TS 5.5.9.d.2, the proposed TS 5.

5.9.d.3 states: "If crack indications are found in any SG tube, then the next inspection for each affected and potentially affected SG for the degradation mechanism that caused the crack indication shall not exceed 24 effective full power months or one refueling outage (whichever results in more frequent inspections). If definitive information, such as from examinat ion of a pulled t ube, diagnostic non-destructive testing, or engi neering evaluation indicates that a crack-like indication is not associated with a crack(s), then the indication need not be treated as a

crack."

TSTF-510, Rev. 2 Page 15 of 20 Specification 5.5.9.d.3 is revised to clarify the term "each SG". The existing wording can be misinterpreted. The intention is that those SGs that are affected and those SGs that are potentially affected must be ins pected for the degradation mechanism that caused the crack indication. However, some licensees have questioned whether the current reference to "each SG" requires only the SGs that ar e affected to be inspected for the degradation mechanism.

Paragraph d.3 is altered as shown to eliminate this ambiguity. The Bases of the Steam Generator Tube Integrity Surveillance (Surveillance 3.4.17.1 in NUREG-1430, Su rveillance 3.4.20.1 in NUR EG-1431, and Surveillance 3.4.18.1 in NUREG-1432) are revised to reflect this clarification.

TS 5.5.9.d.2 [600TT and 690TT] changed the parenthetical expression "(whichever is less)" to "(whichever results in more frequent inspections)" since effective full power months reflect an operating time, whereas o ne refueling outage reflects an event. A conforming change is also made to TS 5.5.9.d.3 to modify the parenthetical expression

"(whichever is less)" is changed to "(whichever results in more frequent inspections)".

Section 2: SG Tube Sample Selection The current technical specifications refe r to the Steam Generat or Program degradation assessment guidance for sampling requirements.

The minimum sample size is 20% of all tubes as a minimum, as required by Reference 1. The proposed change adds a new requirement to increase the minimum number of tubes inspected at each SG inspection based on the number of tubes in all SGs divided by the number of SG outage inspections scheduled during each inspection period.

The Steam Generator Pr ogram requires the prepar ation of a degradation assessment. The degradation assessment is the key document used for planning a SG inspection, where inspection plans and related actions are determined, documented, and communicated. The degradation assessment addresses the various reactor coolant pressure boundary components within the SG (e.g., plugs, sleeves, tubes, and components that suppor t the pressure boundary.) In a degradation assessment, tube sample selection is performance based and is dependent upon actual SG conditions and pl ant operational experience and of the industry in general. Existing and potential degradation mechanisms and their locations are evaluated to determine which tubes will be inspected. Tube sample selection is adjusted to minimize the potential for tube integrit y to degrade during an operating cycle beyond the lim its defined by the performanc e criteria. NEI 97-06 (Ref. 7) and the EPRI Steam Generator Int egrity Assessment Guidelines (Ref. 2) provide guidance on d egradation assessment.

The sample selection considerations requi red by the SG Program (Ref. 1) and the requirements as proposed by this change are consistent. However, added assurance that degradation will be detected is provided by a new requirement to increase the minimum number of tubes inspected at eac h SG inspection based on the number of tubes in all SGs divided by the number of SG outage in spections scheduled during each inspection period. For example; if only one inspection is scheduled during a given inspection period, the minimum sample size would be 100% of the tubes in each steam TSTF-510, Rev. 2 Page 16 of 20 generator. Therefore the sample selection method proposed by this change is more conservative than the current technical specification requirements.

Section 3: Steam Generat or Tube Inspection Report Specification 5.6.7, "Steam Generator Tube Inspection Report," is revised to change the reporting requirements. Paragraph f is re vised to require reporting the effective plugging percentage. Optional paragraph h, which required repor ting the effective plugging percentage, is deleted. Vendors of t ube repair methods provide the equivalent RCS flow reduction to licensees for effective plugging percentage. A licensee may state that the plugging perc entage and the effective plugging percentage are the same.

In addition, the word "active" was removed from paragraphs 5.6.7.b and e. This term is not defined in the specifications.

Conclusion The proposed changes will provide an acceptable level of assurance of SG tube integrity compared to the current technical specifications. The proposed requirements resolve implementation issues associated wi th the current specifications. These changes are consistent with the guidance in NEI 97-06, "Steam Generator Program Guidelines," (Ref. 7). Adopting the proposed changes will provide reasonable assurance th at SG tubing will remain capable of fulfilling its specified safe ty function of maintain ing RCPB integrity. 5.0 REGULATORY ANALYSIS 5.1 No Significant Hazards Consideration The proposed change revises the Improved St andard Technical Spec ification (ISTS)

Specification 5.5.9, "Steam Generator (SG) Program," 5.

6.7, "Steam Generator Tube Inspection Report," and the Steam Generator Tube Integrity Technical Specification (LCO 3.4.17, LCO 3.4.20, and LCO 3.4.18 in ISTS NUREG-1430, -1431, and -1432, respectively) to address inspection peri ods and other administrative changes and clarifications. The TSTF has evaluated whether or not a significant hazards consideration is involved wit h the proposed generic change by focusing on the three standards set forth in 10 CFR 50.92, "Issuanc e of amendment," as discussed below: 1. Does the proposed change involve a significant increa se in the probability or consequences of an accident previously evaluated? Response: No The proposed change revises the Steam Gener ator (SG) Program to modify the frequency of verification of SG tube integrity and SG tube sa mple selection. A steam generator tube rupture (SGTR) event is one of the design basis accidents that are analyzed as part of a plant's licensing basis. The proposed SG tube inspection frequency and sample selection criteria will c ontinue to ensure that the SG tubes are TSTF-510, Rev. 2 Page 17 of 20 inspected such that the probability of a SGTR is not increased. The consequences of a SGTR are bounded by the conservative a ssumptions in the design basis accident analysis. The proposed change will not cause the consequences of a SGTR to exceed those assumptions. The proposed change to reporting requirements and

clarifications of the existing requirem ents have no affect on the probability or consequences of SGTR.

Therefore, it is concluded that the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated. 2. Does the proposed change cr eate the possibility of a new or different kind of accident from any accident previously evaluated? Response: No The proposed changes to the St eam Generator Program will not introduce any adverse changes to the plant design basis or postulated accidents resulting from potential tube degradation. The proposed change does not a ffect the design of the SGs or their method of operation. In addition, the proposed change does not impact any other plant system or component.

Therefore, the proposed change does not create the possibilit y of a new or different type of accident from any accident previously evaluated.

3. Does the proposed change involve a significant reduction in a margin of safety? Response: No

The SG tubes in pressurized water reactors are an integral part of the reactor coolant pressure boundary and, as such, are relied upon to maintain the primary system's pressure and inventory. As part of the reac tor coolant pressure boundary, the SG tubes are unique in that they are also relied up on as a heat transfer surface between the primary and secondary systems such that residual heat can be removed from the primary system. In addi tion, the SG tubes also isolate the radioactive fission products in the primary coolant from the secondary system. In summary, the safety function of a SG is maintained by ensuring the integrity of its tubes.

Steam generator tube int egrity is a function of the desi gn, environment, and the physical condition of the tube. The proposed change does not affect tube design or operating environment. The proposed cha nge will continue to require monitoring of the physical condition of the SG tubes such that there will not be a reduction in the margin of safety compared to the current requirements.

Therefore, it is concluded that the proposed change does not involve a significant reduction in a margin of safety.

TSTF-510, Rev. 2 Page 18 of 20 5.2 Applicable Regulatory Requirements/Criteria The regulatory requirements applicable to SG tube integrity are the following: 10 CFR 50.55a, Codes and Standards - Section (b), ASME Code - c)

Reactor coolant pressure boundary. (1) Components which are part of the reactor coolant pressure boundary must meet the requi rements for Class 1 component s in Section III of the ASME Boiler and Pressure Vessel Code, except as provided in paragraphs (c)(2), (c)(3), and (c)(4) of this section. The proposed change and the Steam Generator Program r equirements which underlie it are in full compliance with the ASME Code. The proposed technical specifications are more effective at ensuring tube integrit y and, therefore, compliance with the ASME Code, than the current technical specifications as described in Section 4.0 (Technical Analysis). 10 CFR 50.65 Maintenance Rule

- Each holder of a license to operate a nuclear power plant under 50.21(b) or 50.22 shall monitor t he performance or condition of structures, systems, or components, against licensee-established goals, in a manner sufficient to provide reasonable assurance that such st ructures, systems, and components, as defined in paragraph (b), are capable of fulfilling their intended functions. Such goals shall be established commensurate with safety and, where practical, take into account industry-wide operating experienc

e. When the performance or condition of a structure, system, or component does not meet established goals, appropriate corrective action shall be taken. For a nuclear power plant for which the licensee has submitted the certifications specified in 50.82(a)(1), this se ction only shall apply to the extent that the licensee shall monitor the performance or c ondition of all struct ures, systems, or components associated with the storage, control, and maintenance of spent fuel in a safe condition, in a manner sufficient to provide reasonable assurance that such structures, systems, and components are capable of fulfilli ng their intended functions. Under the Maintenance Rule, licensees cla ssify SGs as risk significant components because they are relied on to remain function al during and after design basis events.

The performance criteria included in the proposed technical specifications are used to demonstrate that the condition of the SG "is being effect ively controlled through the performance of appropriate preventive maintenance" (Maintenance Rule §(a)(2)). If the performance criteria are not met, a root cause determinat ion of appropriate depth is done and the results evaluated to determine if goals should be established per §(a)(1) of the Maintenance Rule.

NEI 97-06, Steam Generator Program Gui delines, and its referenced EPRI guidelines define a SG program that pr ovides the appropriate prevent ive maintenance that meets the intent of the Maintenanc e Rule. NUMARC 93-01, "Industr y Guideline for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants," (Re

f. 11) offers guidance for implementing the Maintenance Rule should a licensee elect to incorporate additional monitoring goals beyond the scope of those documented in NEI 97-06.

TSTF-510, Rev. 2 Page 19 of 20 10 CFR 50, Appendix A, GDC 14

- Reactor Coolant Pressure Boundary.

The reactor coolant pressure boundary shall be designed, fabricated, erected, and tested so as to have an extremely low probability of abnormal leakage, or rapidly propagating failure, and of gross rupture.

There are no changes to the SG design that impact this general design criteria. The evaluation performed in Section 4.0 concludes that the proposed change will continue to comply with this regulatory requirement.

10 CFR 50, Appendix A, GDC 30 -Quality of reactor co olant pressure boundary. Components which are part of the reactor coolant pressure boundary shall be designed, fabricated, erected, and test ed to the highest quality standards practical. Means shall be provided for detecting and, to the extent practical, identifying the location of the source of reactor coolant leakage.

There are no changes to the SG design that impact this general design criteria. The evaluation performed in Section 4.0 conclude s that the proposed change will continue to comply with this regulatory requirement.

10 CFR 50, Appendix A, GDC 32 - Inspection of reactor coolant pressure boundary.

Components which are part of the reactor coolant pressure boundary shall be designed to (1) periodic inspection and testing of impor tant areas and features to assess their structural and leaktight integrity, and (2) an appropriate material surveillance program

for the reactor pressure vessel.

There are no changes to the SG design that impact this general design criteria. The evaluation performed in Section 4.0 concl udes that the proposed change will continue to comply with this regulatory requirement.

General Design Criteria (GDC) 14, 30, and 32 of 10 CFR Pa rt 50, Appendix A , define requirements for the reactor coolant pressu re boundary with respect to structural and leakage integrity. Steam gener ator tubing and tube repairs constitute a major fraction of the reactor coolant pressu re boundary surface area.

Steam generator tubing and associated repair techniques and components, such as plugs and sleeves, must be capable of maintaining reactor coolant inventory and pressure. The Steam Generator Program required by the proposed technica l specification establishes performance criteria, repair criteria, repair methods, inspection periods and the methods necessary to meet them. These requirements provide reasonable assurance t hat tube integrity will be met in the interval between SG inspections.

The proposed change provides requi rements that are at least as effective in detecting SG degradation and prescribing corrective ac tions. The proposed change results in added assurance of the function and integrity of SG tubes. Therefore, based on the considerations discussed above: 1) There is reasonable assu rance that the health and safety of the public will not be endangered by operation in the proposed manner; TSTF-510, Rev. 2 Page 20 of 20 2) Such activities will be conduct ed in compliance with the Commission's regulations; and 3) Issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.

6.0 ENVIRONMENTAL CONSIDERATION

A review has determined that the proposed change would change a requirement with respect to installation or use of a facility component located within t he restricted areas, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or signifi cant increase in the am ounts of any effluent that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingl y, the proposed change meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c

)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental impac t statement or environmental assessment need be prepared in connection with the proposed change.

7.0 REFERENCES

1. EPRI, "PWR Steam Generator Examination Guidelines" 2. EPRI, "Steam Generator Int egrity Assessment Guidelines" 3. EPRI, "Steam Generator In Si tu Pressure Test Guidelines" 4. EPRI, "PWR Primary-to-Secondary Leak Guidelines" 5. EPRI, "PWR Primary Water Chemistry Guidelines" 6. EPRI, "PWR Secondary Water Chemistry Guidelines"
7. NEI 97-06, "Steam Generat or Program Guidelines." 8. Technical Specification Task Force (TSTF) Standard Technical Specification Change Traveler, TSTF-449 Rev. 4 "Steam Generator Tube Integrity." 9. NRC memo from Catherine Haney to Jim Riley of NEI dated November 9, 2007, "Steam Generator Ins pection Requirements." 10. EPRI Report R-5515-00-2, "Experience of US and Foreign PWR Steam Generators with Alloy 600TT and Alloy 690TT Tubes and Sleeves," June 5, 2002. 11. NUMARC 93-01, "Industry Guideline for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants," Revision 3.

SG Tube Integrity 3.4.17 BWOG STS 3.4.17-1 Rev. 3.1, 12/01/05 3.4 REACTOR COOLANT SYSTEM (RCS)

3.4.17 Steam Generator (SG) Tube Integrity

LCO 3.4.17 SG tube integrity shall be maintained.

AND All SG tubes satisfying the tube plugging [or repair] criteria shall be plugged [or repaired] in accordance with the Steam Generator Program.

APPLICABILITY: MODES 1, 2, 3, and 4.

ACTIONS


NOTE-----------------------------------------------------------

Separate Condition entry is allowed for each SG tube.


CONDITION REQUIRED ACTION COMPLETION TIME

A. One or more SG tubes satisfying the tube plugging [or repair] criteria and not plugged [or repaired] in accordance with the Steam Generator Program.

A.1 Verify tube integrity of the affected tube(s) is maintained until the next refueling outage or SG tube inspection.

AND A.2 Plug [or repair] the affected tube(s) in accordance with the Steam Generator Program.

7 days

Prior to entering MODE 4 following the

next refueling outage or SG tube inspection

B. Required Action and associated Completion

Time of Condition A not met.

OR SG tube integrity not maintained.

B.1 Be in MODE 3.

AND B.2 Be in MODE 5.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SG Tube Integrity 3.4.17 BWOG STS 3.4.17-2 Rev. 3.1, 12/01/05 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.17.1 Verify SG tube integrity in accordance with the Steam Generator Program.

In accordance with the Steam Generator

Program

SR 3.4.17.2 Verify that each inspected SG tube that satisfies the tube plugging [or repair] criteria is plugged [or repaired] in accordance with the Steam Generator Program. Prior to entering

MODE 4 following

a SG tube inspection

Programs and Manuals 5.5 BWOG STS 5.5-5 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.8 Inservice

Testing Program (continued)

ASME OM Code and applicable Addenda terminology for inservice testing activities Required Frequencies for performing inservice testing

activities Weekly At least once per 7 days Monthly At least once per 31 days Quarterly or every 3 months At least once per 92 days Semiannually or every 6 months At least once per 184 days Every 9 months At least once per 276 days Yearly or annually At least once per 366 days Biennially or every 2 years At least once per 731 days

b. The provisions of SR 3.0.2 are applicable to the above required Frequencies and other normal and accelerated Frequencies specified in the Inservice Testing Program for performing inservice testing activities,
c. The provisions of SR 3.0.3 are applicable to inservice testing activities, and
d. Nothing in the ASME OM Code shall be construed to supersede the requirements of any TS.

5.5.9 Steam

Generator (SG) Program A Steam Generator Program shall be established and implemented to ensure that SG tube integrity is maintained. In addition, the Steam Generator Program shall include the following provisions

a. Provisions for condition monitoring assessments. Condition monitoring assessment means an evaluation of the "as found" condition of the tubing with respect to the performance criteria for structural integrity and accident induced leakage. The "as found" condition refers to the condition of the tubing during an SG inspection outage, as determined from the inservice inspection results or by other means, prior to the plugging [or repair] of tubes. Condition monitoring assessments shall be conducted during each outage during which the SG tubes are inspected, plugged, [or repaired] to confirm that the performance criteria are being met.

Programs and Manuals 5.5 BWOG STS 5.5-6 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.9 Steam

Generator (SG) Program (continued)

b. Performance criteria for SG tube integrity. SG tube integrity shall be maintained by meeting the performance criteria for tube structural integrity, accident induced leakage, and operational LEAKAGE.
1. Structural integrity performance criterion: All in-service steam generator tubes shall retain structural integrity over the full range of normal operating conditions (including startup, operation in the power range, hot standby, and cool down

), and all anticipated transients included in the design specification

,) and design basis accidents. This includes retaining a safety factor of 3.0 against burst under normal steady state full power operation primary-to-secondary pressure differential and a safety factor of 1.4 against burst applied to the design basis accident primary-to-secondary pressure differentials.

Apart from the above requirements, additional loading conditions associated with the design basis accidents, or combination of accidents in accordance with the design and licensing basis, shall also be evaluated to determine if the associated loads contribute significantly to burst or collapse. In the assessment of tube integrity, those loads that do significantly affect burst or collapse shall be determined and assessed in combination with the loads due to pressure with a safety factor of 1.2 on the combined primary loads and 1.0 on axial secondary loads.

2. Accident induced leakage performance criterion: The primary to secondary accident induced leakage rate for any design basis accident, other than a SG tube rupture, shall not exceed the leakage rate assumed in the accident analysis in terms of total leakage rate for all SGs and leakage rate for an individual SG. Leakage is not to exceed [1 gpm] per SG [, except for specific types of degradation at specific locations as described in paragraph c of the Steam Generator

Program].

3. The operational LEAKAGE performance criterion is specified in LCO 3.4.13, "RCS Operational LEAKAGE."
c. Provisions for SG tube plugging [or repair] criteria. Tubes found by inservice inspection to contain flaws with a depth equal to or exceeding

[40%] of the nominal tube wall thickness shall be plugged [or repaired].

Programs and Manuals 5.5 BWOG STS 5.5-7 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.9 Steam

Generator (SG) Program (continued)


REVIEWER'S NOTE----------------------------------------

Alternate tube plugging [or repair] criteria currently permitted by plant technical specifications are listed here. The description of these alternate tube plugging

[or repair] criteria should be equivalent to the descriptions in current technical specifications and should also include any allowed accident induced leakage rates for specific types of degradation at specific locations associated with tube plugging [or repair] criteria. ------------------------------------------------------------------------------------------------------------

[The following alternate tube plugging [or repair] criteria may be applied as an alternative to the 40% depth based criteria:

1. . . .]
d. Provisions for SG tube inspections. Periodic SG tube inspections shall be performed. The number and portions of the tubes inspected and methods of inspection shall be performed with the objective of detecting flaws of any type (e.g., volumetric flaws, axial and circumferential cracks) that may be present along the length of the tube, from the tube-to-tubesheet weld at the tube inlet to the tube-to-tubesheet weld at the tube outlet, and that may satisfy the applicable tube plugging [or repair] criteria. The tube-to-tubesheet weld is not part of the tube. In addition to meeting the requirements of d.1, d.2, and d.3 below, the inspection scope, inspection methods, and inspection intervals shall be such as to ensure that SG tube integrity is maintained until the next SG inspection. A n assessment of degradation assessment shall be performed to determine the type and location of flaws to which the tubes may be susceptible and, based on this assessment, to determine which inspection methods need to be employed and at what locations.

REVIEWER'S NOTE------------------------------------- Plants are to include the appropriate Frequency (e.g., select the appropriate Item 2.) for their SG design. The first Item 2 is applicable to SGs with Alloy 600 mill annealed tubing. The second Item 2 is applicable to SGs with Alloy 600 thermally treated tubing. The third Item 2 is applicable to SGs with Alloy 690 thermally treated tubing. ----------------------------------------------------------------------------------------------------

1. Inspect 100% of the tubes in each SG during the first refueling outage following SG installation replacement.

[2. After the first refueling outage following SG installation, inspect each steam generator at least every 24 effective full power months or at least every refueling outage (whichever results in more frequent inspections). In addition, inspect 100% of the tubes at sequential periods of 60 effective full power months beginning after the first Programs and Manuals 5.5 BWOG STS 5.5-8 Rev. 3.1, 12/01/05 refueling outage inspection following SG installation. Each 60 effective full power month inspection period may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage. If a degradation assessment indicates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. Inspect 100% of the tubes at sequential periods of 60 effective full power months. The first sequential period shall be considered to begin after the first inservice inspection of the SGs. No SG shall operate for more than 24 effective full power months or one refueling outage (whichever is less) without being inspected.]

Programs and Manuals 5.5 BWOG STS 5.5-9 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.9 Steam

Generator (SG) Program (continued)

[2. After the first refueling outage following SG installation, inspect each SG at least every 48 effective full power months or at least every other refueling outage (whichever results in more frequent inspections). In addition, the minimum number of tubes inspected at each scheduled inspection shall be the number of tubes in all SGs divided by the number of SG inspection outages scheduled in each inspection period as defined in a, b, and c below. If a degradation assessment indicates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. Each inspection period defined below may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage.


Reviewer's Note ------------------------------------

A licensee may elect to retain historical and existing inspection period lengths in order to not revise those inspection periods.


a) After the first refueling outage following SG installation, inspect 100% of the tubes during the next 120 effective full power months. This constitutes the first inspection period; b) During the next 96 effective full power months, inspect 100% of the tubes. This constitutes the second inspection period; and c) During the remaining life of the SGs, inspect 100% of the tubes every 72 effective full power months. This constitutes the third and subsequent inspection periods.

Inspect 100% of the tubes at sequential periods of 120, 90, and, thereafter, 60 effective full power months. The first sequential period shall be considered to begin after the first inservice inspection of the SGs. In addition, inspect 50% of the tubes by the refueling outage nearest the midpoint of the period and the remaining 50% by the refueling outage nearest the end of the period. No SG shall operate Programs and Manuals 5.5 BWOG STS 5.5-10 Rev. 3.1, 12/01/05 for more than 48 effective full power months or two refueling outages (whichever is less) without being inspected.]

[2. After the first refueling outage following SG installation, inspect each SG at least every 72 effective full power months or at least every third refueling outage (whichever results in more frequent inspections). In addition, the minimum number of tubes inspected at each scheduled inspection shall be the number of tubes in all SGs divided by the number of SG inspection outages scheduled in each inspection period as defined in a, b, c and d below. If a degradation assessment indicates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. Each inspection period defined below may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage.


Reviewer's Note ------------------------------------

A licensee may elect to retain historical and existing inspection period lengths in order to not revise those inspection periods.


a) After the first refueling outage following SG installation, inspect 100% of the tubes during the next 144 effective full power months. This constitutes the first inspection period; b) During the next 120 effective full power months, inspect 100% of the tubes. This constitutes the second inspection period; c) During the next 96 effective full power months, inspect 100% of the tubes. This constitutes the third inspection period; and d) During the remaining life of the SGs, inspect 100% of the tubes every 72 effective full power months. This constitutes the fourth and subsequent inspection periods.

Inspect 100% of the tubes at sequential periods of 144, 108, 72, an d, thereafter, 60 effective full power months. The first sequential period shall be considered to begin after the first inservice inspection of the SGs. In addition, inspect 50% of the tubes by the refueling outage Programs and Manuals 5.5 BWOG STS 5.5-11 Rev. 3.1, 12/01/05 nearest the midpoint of the period and the remaining 50% by the refueling outage nearest the end of the period. No SG shall operate for more than 72 effective full power months or three refueling outages (whichever is less) without being inspected.]

3. If crack indications are found in any SG tube, then the next inspection for each affected and potentially affected SG for the degradation mechanism that caused the crack indication shall not exceed 24 effective full power months or one refueling outage (whichever results in more frequent inspectionsis less). If definitive information, such as from examination of a pulled tube, diagnostic non-destructive testing, or engineering evaluation indicates that a crack-like indication is not associated with a crack(s), then the indication need not be treated as a crack.
e. Provisions for monitoring operational primary to secondary LEAKAGE.

[f. Provisions for SG tube repair methods. Steam generator tube repair methods shall provide the means to reestablish the RCS pressure boundary integrity of SG tubes without removing the tube from service. For the purposes of these Specifications, tube plugging is not a repair. All acceptable tube repair methods are listed below.


REVIEWER'S NOTE---------------------------------------- Tube repair methods currently permitted by plant technical specifications are to be listed here. The description of these tube repair methods should be equivalent to the descriptions in current technical specifications. If there are no approved tube repair methods, this section should not be used. ------------------------------------------------------------------------------------------------------------

1. . . .]

Reporting Requirements 5.6 BWOG STS 5.6-4 Rev. 3.1, 12/01/05 5.6 Reporting Requirements

5.6.5 Post Accident Monitoring Report

When a report is required by Condition B or F of LCO 3.3.[17], "Post Accident Monitoring (PAM) Instrumentation," a report shall be submitted within the following 14 days. The report shall outline the preplanned alternate method of monitoring, the cause of the inoperability, and the plans and schedule for restoring the instrumentation channels of the Function to OPERABLE status.

5.6.6 [ Tendon Surveillance Report Any abnormal degradation of the containment structure detected during the tests required by the Pre-stressed Concrete Containment Tendon Surveillance Program shall be reported to the NRC within 30 days. The report shall include a description of the tendon condition, the condition of the concrete (especially at tendon anchorages), the inspection procedures, the tolerances on cracking, and the corrective action taken. ]

5.6.7 Steam

Generator Tube Inspection Report A report shall be submitted within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.9, "Steam Generator (SG) Program." The report shall include:

a. The scope of inspections performed on each SG, b. Active D degradation mechanisms found,
c. Nondestructive examination techniques utilized for each degradation mechanism, d. Location, orientation (if linear), and measured sizes (if available) of service induced indications, e. Number of tubes plugged [or repaired] during the inspection outage for each active degradation mechanism,
f. The number and percentage of tubes plugged [or repaired] to date, and the effective plugging percentage in each steam generatorTotal number and percentage of tubes plugged [or repaired] to date ,
g. The results of condition monitoring, including the results of tube pulls and in-situ testing,

[h. The effective plugging percentage for all plugging [and tube repairs] in each SG, and] [h i. Repair method utilized and the number of tubes repaired by each repair method.]

SG Tube Integrity B 3.4.17 BWOG STS B 3.4.17-2 Rev. 3.1, 12/01/05 BASES

APPLICABLE The steam generator tube rupture (SGTR) accident is the limiting design SAFETY basis event for SG tubes and avoiding an SGTR is the basis for this ANALYSES Specification. The analysis of a SGTR event assumes a bounding primary to secondary LEAKAGE rate equal to the operational LEAKAGE rate limits in LCO 3.4.13, "RCS Operational LEAKAGE," plus the leakage rate associated with a double-ended rupture of a single tube. The accident analysis for a SGTR assumes the contaminated secondary fluid is only briefly released to the atmosphere via safety valves and the majority is discharged to the main condenser.

The analysis for design basis accidents and transients other than a SGTR assume the SG tubes retain their structural integrity (i.e., they are assumed not to rupture.) In these analyses, the steam discharge to the atmosphere is based on the total primary to secondary LEAKAGE from all SGs of [1 gallon per minute] or is assumed to increase to [1 gallon per minute] as a result of accident induced conditions. For accidents that do not involve fuel damage, the primary coolant activity level of DOSE EQUIVALENT I-131 is assumed to be equal to the LCO 3.4.16, "RCS Specific Activity," limits. For accidents that assume fuel damage, the primary coolant activity is a function of the amount of activity released from the damaged fuel. The dose consequences of these events are

within the limits of GDC 19 (Ref. 2), 10 CFR 100 (Ref. 3) or the NRC

approved licensing basis (e.g., a small fraction of these limits).

Steam generator tube integrity satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii).

LCO The LCO requires that SG tube integrity be maintained. The LCO also requires that all SG tubes that satisfy the plugging [or repair] criteria be plugged [or repaired] in accordance with the Steam Generator Program.

During an SG inspection, any inspected tube that satisfies the Steam

Generator Program plugging [or repair] criteria is [repaired or] removed from service by plugging. If a tube was determined to satisfy the plugging [or repair] criteria but was not plugged [or repaired], the tube may still have tube integrity.

In the context of this Specification, a SG tube is defined as the entire length of the tube, including the tube wall [and any repairs made to it],

between the tube-to-tubesheet weld at the tube inlet and the tube-to-tubesheet weld at the tube outlet. The tube-to-tubesheet weld is not considered part of the tube.

A SG tube has tube integrity when it satisfies the SG performance criteria.

The SG performance criteria are defined in Specification 5.5.9, "Steam Generator Program," and describe acceptable SG tube performance. The Steam Generator Program also pr ovides the evaluation process for determining conformance with the SG performance criteria.

SG Tube Integrity B 3.4.17 BWOG STS B 3.4.17-4 Rev. 3.1, 12/01/05 BASES

LCO (continued)

The operational LEAKAGE performance criterion provides an observable indication of SG tube conditions during plant operation. The limit on operational LEAKAGE is contained in LCO 3.4.13, "RCS Operational LEAKAGE," and limits primary to secondary LEAKAGE through any one SG to 150 gallons per day. This limit is based on the assumption that a single crack leaking this amount would not propagate to a SGTR under the stress conditions of a LOCA or a main steam line break. If this amount of LEAKAGE is due to more than one crack, the cracks are very small, and the above assumption is conservative.

APPLICABILITY Steam generator tube integrity is challenged when the pressure differential across the tubes is large. Large differential pressures across SG tubes can only be experienced in MODE 1, 2, 3, or 4.

RCS conditions are far less challenging in MODES 5 and 6 than during MODES 1, 2, 3, and 4. In MODES 5 and 6, primary to secondary differential pressure is low, resulting in lower stresses and reduced potential for LEAKAGE.

ACTIONS The ACTIONS are modified by a Note clarifying that the Conditions may be entered independently for each SG tube. This is acceptable because the Required Actions provide appropriate compensatory actions for each affected SG tube. Complying with the Required Actions may allow for continued operation, and subsequent affected SG tubes are governed by subsequent Condition entry and application of associated Required Actions.

A.1 and A.2 Condition A applies if it is discovered that one or more SG tubes examined in an inservice inspection satisfy the tube plugging [or repair] criteria but were not plugged [or repaired] in accordance with the Steam Generator Program as required by SR 3.4.17.2. An evaluation of SG tube integrity of the affected tube(s) must be made. Steam generator tube integrity is based on meeting the SG performance criteria described in the Steam Generator Program. The SG plugging [or repair] criteria define limits on SG tube degradation that allow for flaw growth between inspections while still providing assurance that the SG performance criteria will continue to be met. In order to determine if a SG tube that should have been plugged [or repaired] has tube integrity, an evaluation must be completed that demonstrates that the SG performance criteria will continue to be met until the next refueling outage or SG tube inspection. The tube integrity SG Tube Integrity B 3.4.17 BWOG STS B 3.4.17-6 Rev. 3.1, 12/01/05 BASES

SURVEILLANCE REQUIREMENTS (continued)

The Steam Generator Program determines the scope of the inspection and the methods used to determine whether the tubes contain flaws satisfying the tube plugging [or repair] criteria. Inspection scope (i.e., which tubes or areas of tubing within the SG are to be inspected) is a function of existing and potential degradation locations. The Steam Generator Program also specifies the inspection methods to be used to find potential degradation. Inspection methods are a function of degradation morphology, non-destructive examination (NDE) technique capabilities, and inspection locations.

The Steam Generator Program defines the Frequency of SR 3.4.17.1. The Frequency is determined by the operational assessment and other limits in the SG examination guidelines (Ref. 6). The Steam Generator Program uses information on existing degradations and growth rates to determine an inspection Frequency that provides reasonable assurance that the tubing will meet the SG performance criteria at the next scheduled inspection. In addition, Specification 5.5.9 contains prescriptive requirements concerning inspection intervals to provide added assurance that the SG performance criteria will be met between scheduled inspections. If crack indications are found in any SG tube, the maximum inspection interval for all affected and potentially affected SGs is restricted by Specification 5.5.9 until subsequent inspections support extending the inspection interval.

SR 3.4.17.2

During an SG inspection, any inspected tube that satisfies the Steam Generator Program plugging [or repair] criteria is [repaired or] removed from service by plugging. The tube plugging [or repair] criteria delineated in Specification 5.5.9 are intended to ensure that tubes accepted for continued service satisfy the SG performance criteria with allowance for error in the flaw size measurement and for future flaw growth. In addition, the tube plugging [or repair] criteria, in conjunction with other elements of the Steam Generator Program, ensure that the SG performance criteria will continue to be met until the next inspection of the subject tube(s).

Reference 1 provides guidance for performing operational assessments to verify that the tubes remaining in service will continue to meet the SG performance criteria.

[Steam generator tube repairs are only performed using approved repair methods as described in the Steam Generator Program.]

The Frequency of prior to entering MODE 4 following a SG inspection ensures that the Surveillance has been completed and all tubes meeting SG Tube Integrity B 3.4.17 BWOG STS B 3.4.17-7 Rev. 3.1, 12/01/05 the plugging [or repair] criteria are plugged [or repaired] prior to subjecting the SG tubes to significant primary to secondary pressure differential.

SG Tube Integrity 3.4.20 WOG STS 3.4.20-1 Rev. 3.1, 12/01/05 3.4 REACTOR COOLANT SYSTEM (RCS)

3.4.20 Steam Generator (SG) Tube Integrity

LCO 3.4.20 SG tube integrity shall be maintained.

AND All SG tubes satisfying the tube plugging [or repair] criteria shall be plugged [or repaired] in accordance with the Steam Generator Program.

APPLICABILITY: MODES 1, 2, 3, and 4.

ACTIONS


NOTE-----------------------------------------------------------

Separate Condition entry is allowed for each SG tube.


CONDITION REQUIRED ACTION COMPLETION TIME

A. One or more SG tubes satisfying the tube

plugging [or repair] criteria and not plugged

[or repaired] in accordance with the Steam Generator Program.

A.1 Verify tube integrity of the affected tube(s) is

maintained until the next refueling outage or SG tube inspection.

AND A.2 Plug [or repair] the affected tube(s) in accordance with the Steam Generator Program.

7 days

Prior to entering MODE 4 following the next refueling outage or SG tube inspection

B. Required Action and associated Completion Time of Condition A not met.

OR SG tube integrity not maintained.

B.1 Be in MODE 3.

AND B.2 Be in MODE 5.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SG Tube Integrity 3.4.20 WOG STS 3.4.20-2 Rev. 3.1, 12/01/05 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.20.1 Verify SG tube integrity in accordance with the Steam Generator Program.

In accordance with the Steam Generator

Program

SR 3.4.20.2 Verify that each inspected SG tube that satisfies the tube plugging [or repair] criteria is plugged [or repaired] in accordance with the Steam Generator Program. Prior to entering

MODE 4 following

a SG tube inspection

Programs and Manuals 5.5 WOG STS 5.5-5 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.7 Reactor

Coolant Pump Flywheel Inspection Program (continued)


REVIEWER'S NOTE---------------------------------------- The inspection interval and scope for RCP flywheels stated above can be applied to plants that satisfy the requirements in WCAP-15666, "Extension of Reactor Coolant Pump Motor Flywheel Examination." ------------------------------------------------------------------------------------------------------------

5.5.8 Inservice

Testing Program This program provides controls for inservice testing of ASME Code Class 1, 2, and 3 components. The program shall include the following:

a. Testing frequencies applicable to the ASME Code for Operations and Maintenance of Nuclear Power Plants (ASME OM Code) and applicable Addenda as follows:

ASME OM Code and applicable Addenda terminology for inservice testing activities Required Frequencies for performing inservice testing activities Weekly At least once per 7 days Monthly At least once per 31 days Quarterly or every 3 months At least once per 92 days Semiannually or every 6 months At least once per 184 days Every 9 months At least once per 276 days Yearly or annually At least once per 366 days Biennially or every 2 years At least once per 731 days

b. The provisions of SR 3.0.2 are applicable to the above required Frequencies and other normal and accelerated Frequencies specified in the Inservice Testing Program for performing inservice testing activities,
c. The provisions of SR 3.0.3 are applicable to inservice testing activities, and
d. Nothing in the ASME OM Code shall be construed to supersede the requirements of any TS.

Programs and Manuals 5.5 WOG STS 5.5-6 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.9 Steam

Generator (SG) Program A Steam Generator Program shall be established and implemented to ensure that SG tube integrity is maintained. In addition, the Steam Generator Program shall include the following provisions

a. Provisions for condition monitoring assessments. Condition monitoring assessment means an evaluation of the "as found" condition of the tubing with respect to the performance criteria for structural integrity and accident induced leakage. The "as found" condition refers to the condition of the tubing during an SG inspection outage, as determined from the inservice inspection results or by other means, prior to the plugging [or repair] of tubes. Condition monitoring assessments shall be conducted during each outage during which the SG tubes are inspected, plugged, [or repaired] to confirm that the performance criteria are being met.
b. Performance criteria for SG tube integrity. SG tube integrity shall be maintained by meeting the performance criteria for tube structural integrity, accident induced leakage, and operational LEAKAGE.
1. Structural integrity performance criterion: All in-service steam generator tubes shall retain structural integrity over the full range of normal operating conditions (including startup, operation in the power range, hot standby, and cool down

), and all anticipated transients included in the design specification

,) and design basis accidents. This includes retaining a safety factor of 3.0 against burst under normal steady state full power operation primary-to-secondary pressure differential and a safety factor of 1.4 against burst applied to the design basis accident primary-to-secondary pressure differentials. Apart from the above requirements, additional loading conditions associated with the design basis accidents, or combination of accidents in accordance with the design and licensing basis, shall also be evaluated to determine if the associated loads contribute significantly to burst or collapse. In the assessment of tube integrity, those loads that do significantly affect burst or collapse shall be determined and assessed in combination with the loads due to pressure with a safety factor of 1.2 on the combined primary loads and 1.0 on axial secondary loads.

2. Accident induced leakage performance criterion: The primary to secondary accident induced leakage rate for any design basis accident, other than a SG tube rupture, shall not exceed the leakage rate assumed in the accident analysis in terms of total leakage rate for all SGs and leakage rate for an individual SG. Leakage is not to exceed [1 gpm] per SG [, except for specific types of degradation at specific locations as described in paragraph c of the Steam Generator

Program].

Programs and Manuals 5.5 WOG STS 5.5-7 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.9 Steam

Generator (SG) Program (continued)

3. The operational LEAKAGE performance criterion is specified in LCO 3.4.13, "RCS Operational LEAKAGE."
c. Provisions for SG tube plugging [or repair] criteria. Tubes found by inservice inspection to contain flaws with a depth equal to or exceeding

[40%] of the nominal tube wall thickness shall be plugged [or repaired].


REVIEWER'S NOTE----------------------------------------

Alternate tube plugging [or repair] criteria currently permitted by plant technical specifications are listed here. The description of these alternate tube plugging [or repair] criteria should be equivalent to the descriptions in current technical specifications and should also include any allowed accident induced leakage rates for specific types of degradation at specific locations associated with tube plugging [or repair] criteria. ---------------------------------------------------------------------------------------------------------------

[The following alternate tube plugging [or repair] criteria may be applied as an alternative to the 40% depth based criteria:

1. . . .]
d. Provisions for SG tube inspections. Periodic SG tube inspections shall be performed. The number and portions of the tubes inspected and methods of inspection shall be performed with the objective of detecting flaws of any type (e.g., volumetric flaws, axial and circumferential cracks) that may be present along the length of the tube, from the tube-to-tubesheet weld at the tube inlet to the tube-to-tubesheet weld at the tube outlet, and that may satisfy the applicable tube plugging [or repair] criteria. The tube-to-tubesheet weld is not part of the tube. In addition to meeting the requirements of d.1, d.2, and d.3 below, the inspection scope, inspection methods, and inspection intervals shall be such as to ensure that SG tube integrity is maintained until the next SG inspection. A n assessment of degradation assessment shall be performed to determine the type and location of flaws to which the tubes may be susceptible and, based on this assessment, to determine which inspection methods need to be employed and at what locations.

Programs and Manuals 5.5 WOG STS 5.5-8 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.9 Steam

Generator (SG) Program (continued)


REVIEWER'S NOTE---------------------------------------- Plants are to include the appropriate Frequency (e.g., select the appropriate Item 2.) for their SG design. The first Item 2 is applicable to SGs with Alloy 600 mill annealed tubing. The second Item 2 is applicable to SGs with Alloy 600 thermally treated tubing. The third Item 2 is applicable to SGs with Alloy 690 thermally treated tubing. ------------------------------------------------------------------------------------------------------------

1. Inspect 100% of the tubes in each SG during the first refueling outage following SG installation replacement. [2. After the first refueling outage following SG installation, inspect each steam generator at least every 24 effective full power months or at least every refueling outage (whichever results in more frequent inspections). In addition, inspect 100% of the tubes at sequential periods of 60 effective full power months beginning after the first refueling outage inspection following SG installation. Each 60 effective full power month inspection period may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage. If a degradation assessment indicates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. Inspect 100% of the tubes at sequential periods of 60 effective full power months. The first sequential period shall be considered to begin after the first inservice inspection of the SGs. No SG shall operate for more than 24 effective full power months or one refueling outage (whichever is less) without being inspected.]

[2. After the first refueling outage following SG installation, inspect each SG at least every 48 effective full power months or at least every other refueling outage (whichever results in more frequent inspections). In addition, the minimum number of tubes inspected at each scheduled inspection shall be the number of tubes in all SGs divided by the number of SG inspection outages scheduled in each inspection period as defined in a, b, and c below. If a degradation assessment indicates Programs and Manuals 5.5 WOG STS 5.5-9 Rev. 3.1, 12/01/05 the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. Each inspection period defined below may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage.


Reviewer's Note ------------------------------------

A licensee may elect to retain historical and existing inspection period lengths in order to not revise those inspection periods.


a) After the first refueling outage following SG installation, inspect 100% of the tubes during the next 120 effective full power months. This constitutes the first inspection period; b) During the next 96 effective full power months, inspect 100% of the tubes. This constitutes the second inspection period; and c) During the remaining life of the SGs, inspect 100% of the tubes every 72 effective full power months. This constitutes the third and subsequent inspection periods.

Inspect 100% of the tubes at sequential periods of 120, 90, and, thereafter, 60 effective full power months. The first sequential period shall be considered to begin after the first inservice inspection of the SGs. In addition, inspect 50% of the tubes by the refueling outage nearest the midpoint of the period and the remaining 50% by the refueling outage nearest the end of the period. No SG shall operate for more than 48 effective full power months or two refueling outages (whichever is less) without being inspected.]

[2. After the first refueling outage following SG installation, inspect each SG at least every 72 effective full power months or at least every third refueling outage (whichever results in more frequent inspections). In addition, the minimum number of tubes inspected at each scheduled inspection shall be the number of tubes in all SGs divided by the number of SG inspection outages scheduled in each inspection period as defined in a, b, c and d below. If a degradation assessment indicates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type Programs and Manuals 5.5 WOG STS 5.5-10 Rev. 3.1, 12/01/05 of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. Each inspection period defined below may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage.


Reviewer's Note ------------------------------------

A licensee may elect to retain historical and existing inspection period lengths in order to not revise those inspection periods.


a) After the first refueling outage following SG installation, inspect 100% of the tubes during the next 144 effective full power months. This constitutes the first inspection period; b) During the next 120 effective full power months, inspect 100% of the tubes. This constitutes the second inspection period; c) During the next 96 effective full power months, inspect 100% of the tubes. This constitutes the third inspection period; and d) During the remaining life of the SGs, inspect 100% of the tubes every 72 effective full power months. This constitutes the fourth and subsequent inspection periods.

Inspect 100% of the tubes at sequential periods of 144, 108, 72, and, thereafter, 60 effective full power months. The first sequential period shall be considered to begin after the first inservice inspection of the SGs. In addition, inspect 50% of the tubes by the refueling outage nearest the midpoint of the period and the remaining 50% by the refueling outage nearest the end of the period. No SG shall operate for more than 72 effective full power months or three refueling outages (whichever is less) without being inspected.]

3. If crack indications are found in any SG tube, then the next inspection for each affected and potentially affected SG for the degradation mechanism that caused the crack indication shall not exceed 24 effective full power months or one refueling outage (whichever results in more frequent inspectionsis less). If definitive information, such as from examination of a pulled tube, diagnostic non-destructive testing, or engineering evaluation indicates that a crack-like indication Programs and Manuals 5.5 WOG STS 5.5-11 Rev. 3.1, 12/01/05 is not associated with a crack(s), then the indication need not be treated as a crack.
e. Provisions for monitoring operational primary to secondary LEAKAGE.

Programs and Manuals 5.5 WOG STS 5.5-12 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.9 Steam

Generator (SG) Program (continued)

[f. Provisions for SG tube repair methods. Steam generator tube repair methods shall provide the means to reestablish the RCS pressure boundary integrity of SG tubes without removing the tube from service. For the purposes of these Specifications, tube plugging is not a repair. All acceptable tube repair methods are listed below.


REVIEWER'S NOTE---------------------------------------- Tube repair methods currently permitted by plant technical specifications are to be listed here. The description of these tube repair methods should be equivalent to the descriptions in current technical specifications. If there are no approved tube repair methods, this section should not be used. ------------------------------------------------------------------------------------------------------------

1. . . .]

5.5.10 Secondary Water Chemistry Program This program provides controls for monitoring secondary water chemistry to inhibit SG tube degradation and low pressure turbine disc stress corrosion cracking. The program shall include:

a. Identification of a sampling schedule for the critical variables and control points for these variables,
b. Identification of the procedures used to measure the values of the critical variables,
c. Identification of process sampling points, which shall include monitoring the discharge of the condensate pumps for evidence of condenser in leakage,
d. Procedures for the recording and management of data,
e. Procedures defining corrective actions for all off control point chemistry conditions, and
f. A procedure identifying the authority responsible for the interpretation of the data and the sequence and timing of administrative events, which is required to initiate corrective action.

Reporting Requirements 5.6 WOG STS 5.6-4 Rev. 3.1, 12/01/05 5.6 Reporting Requirements

5.6.5 Post Accident Monitoring Report

When a report is required by Condition B or F of LCO 3.3.[3], "Post Accident Monitoring (PAM) Instrumentation," a report shall be submitted within the following 14 days. The report shall outline the preplanned alternate method of monitoring, the cause of the inoperability, and the plans and schedule for restoring the instrumentation channels of the Function to OPERABLE status.

5.6.6 [ Tendon Surveillance Report Any abnormal degradation of the containment structure detected during the tests required by the Pre-stressed Concrete Containment Tendon Surveillance Program shall be reported to the NRC within 30 days. The report shall include a description of the tendon condition, the condition of the concrete (especially at tendon anchorages), the inspection procedures, the tolerances on cracking, and the corrective action taken. ]

5.6.7 Steam

Generator Tube Inspection Report A report shall be submitted within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.9, "Steam Generator (SG) Program." The report shall include:

a. The scope of inspections performed on each SG, b. Active D degradation mechanisms found,
c. Nondestructive examination techniques utilized for each degradation mechanism, d. Location, orientation (if linear), and measured sizes (if available) of service induced indications, e. Number of tubes plugged [or repaired] during the inspection outage for each active degradation mechanism,
f. The number and percentage of tubes plugged [or repaired] to date, and the effective plugging percentage in each steam generatorTotal number and percentage of tubes plugged [or repaired] to date ,
g. The results of condition monitoring, including the results of tube pulls and in-situ testing, [h. The effective plugging percentage for all plugging [and tube repairs] in each SG, and] [h i. Repair method utilized and the number of tubes repaired by each repair method.]

SG Tube Integrity B 3.4.20 WOG STS B 3.4.20-2 Rev. 3.1, 12/01/05 BASES

APPLICABLE The steam generator tube rupture (SGTR) accident is the limiting design SAFETY basis event for SG tubes and avoiding an SGTR is the basis for this ANALYSES Specification. The analysis of a SGTR event assumes a bounding primary to secondary LEAKAGE rate equal to the operational LEAKAGE rate limits in LCO 3.4.13, "RCS Operational LEAKAGE," plus the leakage rate associated with a double-ended rupture of a single tube. The accident analysis for a SGTR assumes the contaminated secondary fluid is only briefly released to the atmosphere via safety valves and the majority is discharged to the main condenser.

The analysis for design basis accidents and transients other than a SGTR assume the SG tubes retain their structural integrity (i.e., they are assumed not to rupture.) In these analyses, the steam discharge to the atmosphere is based on the total primary to secondary LEAKAGE from all SGs of [1 gallon per minute] or is assumed to increase to [1 gallon per minute] as a result of accident induced conditions. For accidents that do not involve fuel damage, the primary coolant activity level of DOSE EQUIVALENT I-131 is assumed to be equal to the LCO 3.4.16, "RCS Specific Activity," limits. For accidents that assume fuel damage, the primary coolant activity is a function of the amount of activity released from the damaged fuel. The dose consequences of these events are

within the limits of GDC 19 (Ref. 2), 10 CFR 100 (Ref. 3) or the NRC

approved licensing basis (e.g., a small fraction of these limits).

Steam generator tube integrity satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii).

LCO The LCO requires that SG tube integrity be maintained. The LCO also requires that all SG tubes that satisfy the plugging [or repair] criteria be plugged [or repaired] in accordance with the Steam Generator Program.

During an SG inspection, any inspected tube that satisfies the Steam

Generator Program plugging [or repair] criteria is [repaired or] removed from service by plugging. If a tube was determined to satisfy the plugging [or repair] criteria but was not plugged [or repaired], the tube may still have tube integrity.

In the context of this Specification, a SG tube is defined as the entire length of the tube, including the tube wall [and any repairs made to it],

between the tube-to-tubesheet weld at the tube inlet and the tube-to-tubesheet weld at the tube outlet. The tube-to-tubesheet weld is not considered part of the tube.

A SG tube has tube integrity when it satisfies the SG performance criteria.

The SG performance criteria are defined in Specification 5.5.9, "Steam Generator Program," and describe acceptable SG tube performance. The Steam Generator Program also pr ovides the evaluation process for determining conformance with the SG performance criteria.

SG Tube Integrity B 3.4.20 WOG STS B 3.4.20-4 Rev. 3.1, 12/01/05 BASES

LCO (continued)

The operational LEAKAGE performance criterion provides an observable indication of SG tube conditions during plant operation. The limit on operational LEAKAGE is contained in LCO 3.4.13, "RCS Operational LEAKAGE," and limits primary to secondary LEAKAGE through any one SG to 150 gallons per day. This limit is based on the assumption that a single crack leaking this amount would not propagate to a SGTR under the stress conditions of a LOCA or a main steam line break. If this amount of LEAKAGE is due to more than one crack, the cracks are very small, and the above assumption is conservative.

APPLICABILITY Steam generator tube integrity is challenged when the pressure differential across the tubes is large. Large differential pressures across SG tubes can only be experienced in MODE 1, 2, 3, or 4.

RCS conditions are far less challenging in MODES 5 and 6 than during MODES 1, 2, 3, and 4. In MODES 5 and 6, primary to secondary differential pressure is low, resulting in lower stresses and reduced potential for LEAKAGE.

ACTIONS The ACTIONS are modified by a Note clarifying that the Conditions may be entered independently for each SG tube. This is acceptable because the Required Actions provide appropriate compensatory actions for each affected SG tube. Complying with the Required Actions may allow for continued operation, and subsequent affected SG tubes are governed by subsequent Condition entry and application of associated Required Actions.

A.1 and A.2 Condition A applies if it is discovered that one or more SG tubes examined in an inservice inspection satisfy the tube plugging [or repair] criteria but were not plugged [or repaired] in accordance with the Steam Generator Program as required by SR 3.4.20.2. An evaluation of SG tube integrity of the affected tube(s) must be made. Steam generator tube integrity is based on meeting the SG performance criteria described in the Steam Generator Program. The SG plugging [or repair] criteria define limits on SG tube degradation that allow for flaw growth between inspections while still providing assurance that the SG performance criteria will continue to be met. In order to determine if a SG tube that should have been plugged [or repaired] has tube integrity, an evaluation must be completed that demonstrates that the SG performance criteria will continue to be met until the next refueling outage or SG tube inspection. The tube integrity SG Tube Integrity B 3.4.20 WOG STS B 3.4.20-6 Rev. 3.1, 12/01/05 BASES

SURVEILLANCE REQUIREMENTS (continued)

The Steam Generator Program determines the scope of the inspection and the methods used to determine whether the tubes contain flaws satisfying the tube plugging [or repair] criteria. Inspection scope (i.e., which tubes or areas of tubing within the SG are to be inspected) is a function of existing and potential degradation locations. The Steam Generator Program also specifies the inspection methods to be used to find potential degradation. Inspection methods are a function of degradation morphology, non-destructive examination (NDE) technique capabilities, and inspection locations.

The Steam Generator Program defines the Frequency of SR 3.4.20.1. The Frequency is determined by the operational assessment and other limits in the SG examination guidelines (Ref. 6). The Steam Generator Program uses information on existing degradations and growth rates to determine an inspection Frequency that provides reasonable assurance that the tubing will meet the SG performance criteria at the next scheduled inspection. In addition, Specification 5.5.9 contains prescriptive requirements concerning inspection intervals to provide added assurance that the SG performance criteria will be met between scheduled inspections. If crack indications are found in any SG tube, the maximum inspection interval for all affected and potentially affected SGs is restricted by Specification 5.5.9 until subsequent inspections support extending the inspection interval.

SR 3.4.20.2

During an SG inspection, any inspected tube that satisfies the Steam Generator Program plugging [or repair] criteria is [repaired or] removed from service by plugging. The tube plugging [or repair] criteria delineated in Specification 5.5.9 are intended to ensure that tubes accepted for continued service satisfy the SG performance criteria with allowance for error in the flaw size measurement and for future flaw growth. In addition, the tube plugging [or repair] criteria, in conjunction with other elements of the Steam Generator Program, ensure that the SG performance criteria will continue to be met until the next inspection of the subject tube(s).

Reference 1 provides guidance for performing operational assessments to verify that the tubes remaining in service will continue to meet the SG performance criteria.

[Steam generator tube repairs are only performed using approved repair methods as described in the Steam Generator Program.]

The Frequency of prior to entering MODE 4 following a SG inspection ensures that the Surveillance has been completed and all tubes meeting SG Tube Integrity B 3.4.20 WOG STS B 3.4.20-7 Rev. 3.1, 12/01/05 the plugging [or repair] criteria are plugged [or repaired] prior to subjecting the SG tubes to significant primary to secondary pressure differential.

SG Tube Integrity 3.4.18 CEOG STS 3.4.18-1 Rev. 3.1, 12/01/05 3.4 REACTOR COOLANT SYSTEM (RCS)

3.4.18 Steam Generator (SG) Tube Integrity

LCO 3.4.18 SG tube integrity shall be maintained.

AND All SG tubes satisfying the tube plugging [or repair] criteria shall be plugged [or repaired] in accordance with the Steam Generator Program.

APPLICABILITY: MODES 1, 2, 3, and 4.

ACTIONS


NOTE-----------------------------------------------------------

Separate Condition entry is allowed for each SG tube.


CONDITION REQUIRED ACTION COMPLETION TIME

A. One or more SG tubes satisfying the tube

plugging [or repair] criteria and not plugged

[or repaired] in accordance with the Steam Generator Program.

A.1 Verify tube integrity of the affected tube(s) is

maintained until the next refueling outage or SG tube inspection.

AND A.2 Plug [or repair] the affected tube(s) in accordance with the Steam Generator Program.

7 days

Prior to entering MODE 4 following the next refueling outage or SG tube inspection

B. Required Action and associated Completion Time of Condition A not met.

OR SG tube integrity not maintained.

B.1 Be in MODE 3.

AND B.2 Be in MODE 5.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SG Tube Integrity 3.4.18 CEOG STS 3.4.18-2 Rev. 3.1, 12/01/05 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.18.1 Verify SG tube integrity in accordance with the Steam Generator Program.

In accordance with the Steam Generator

Program

SR 3.4.18.2 Verify that each inspected SG tube that satisfies the tube plugging [or repair] criteria is plugged [or repaired] in accordance with the Steam Generator Program. Prior to entering

MODE 4 following

a SG tube inspection

Programs and Manuals 5.5 CEOG STS 5.5-5 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.8 Inservice

Testing Program (continued)

ASME OM Code and applicable Addenda terminology for inservice testing activities Required Frequencies for performing inservice testing

activities Weekly At least once per 7 days Monthly At least once per 31 days Quarterly or every 3 months At least once per 92 days Semiannually or every 6 months At least once per 184 days Every 9 months At least once per 276 days Yearly or annually At least once per 366 days Biennially or every 2 years At least once per 731 days

b. The provisions of SR 3.0.2 are applicable to the above required Frequencies and other normal and accelerated Frequencies specified in the Inservice Testing Program for performing inservice testing activities,
c. The provisions of SR 3.0.3 are applicable to inservice testing activities, and
d. Nothing in the ASME OM Code shall be construed to supersede the requirements of any TS.

5.5.9 Steam

Generator (SG) Program A Steam Generator Program shall be established and implemented to ensure that SG tube integrity is maintained. In addition, the Steam Generator Program shall include the following provisions

a. Provisions for condition monitoring assessments. Condition monitoring assessment means an evaluation of the "as found" condition of the tubing with respect to the performance criteria for structural integrity and accident induced leakage. The "as found" condition refers to the condition of the tubing during an SG inspection outage, as determined from the inservice inspection results or by other means, prior to the plugging [or repair] of tubes. Condition monitoring assessments shall be conducted during each outage during which the SG tubes are inspected, plugged, [or repaired] to confirm that the performance criteria are being met.
b. Performance criteria for SG tube integrity. SG tube integrity shall be maintained by meeting the performance criteria for tube structural integrity, accident induced leakage, and operational LEAKAGE.

Programs and Manuals 5.5 CEOG STS 5.5-6 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.9 Steam

Generator (SG) Program (continued)

1. Structural integrity performance criterion: All in-service steam generator tubes shall retain structural integrity over the full range of normal operating conditions (including startup, operation in the power range, hot standby, and cool down

), and all anticipated transients included in the design specification

,) and design basis accidents. This includes retaining a safety factor of 3.0 against burst under normal steady state full power operation primary-to-secondary pressure differential and a safety factor of 1.4 against burst applied to the design basis accident primary-to-secondary pressure differentials. Apart from the above requirements, additional loading conditions associated with the design basis accidents, or combination of accidents in accordance with the design and licensing basis, shall also be evaluated to determine if the associated loads contribute significantly to burst or collapse. In the assessment of tube integrity, those loads that do significantly affect burst or collapse shall be determined and assessed in combination with the loads due to pressure with a safety factor of 1.2 on the combined primary loads and 1.0 on axial secondary loads.

2. Accident induced leakage performance criterion: The primary to secondary accident induced leakage rate for any design basis accident, other than a SG tube rupture, shall not exceed the leakage rate assumed in the accident analysis in terms of total leakage rate for all SGs and leakage rate for an individual SG. Leakage is not to exceed [1 gpm] per SG [, except for specific types of degradation at specific locations as described in paragraph c of the Steam Generator

Program.]

3. The operational LEAKAGE performance criterion is specified in LCO 3.4.13, "RCS Operational LEAKAGE."
c. Provisions for SG tube plugging [or repair] criteria. Tubes found by inservice inspection to contain flaws with a depth equal to or exceeding

[40%] of the nominal tube wall thickness shall be plugged [or repaired].


REVIEWER'S NOTE----------------------------------------

Alternate tube plugging [or repair] criteria currently permitted by plant technical specifications are listed here. The description of these alternate tube plugging [or repair] criteria should be equivalent to the descriptions in current technical specifications and should also include any allowed accident induced leakage rates for specific types of degradation at specific locations associated with tube plugging [or repair] criteria. ---------------------------------------------------------------------------------------------------------------

Programs and Manuals 5.5 CEOG STS 5.5-7 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.9 Steam

Generator (SG) Program (continued)

[The following alternate tube plugging [or repair] criteria may be applied as an alternative to the 40% depth based criteria:

1. . . .]
d. Provisions for SG tube inspections. Periodic SG tube inspections shall be performed. The number and portions of the tubes inspected and methods of inspection shall be performed with the objective of detecting flaws of any type (e.g., volumetric flaws, axial and circumferential cracks) that may be present along the length of the tube, from the tube-to-tubesheet weld at the tube inlet to the tube-to-tubesheet weld at the tube outlet, and that may satisfy the applicable tube plugging [or repair] criteria. The tube-to-tubesheet weld is not part of the tube. In addition to meeting the requirements of d.1, d.2, and d.3 below, the inspection scope, inspection methods, and inspection intervals shall be such as to ensure that SG tube integrity is maintained until the next SG inspection. A n assessment of degradation assessment shall be performed to determine the type and location of flaws to which the tubes may be susceptible and, based on this assessment, to determine which inspection methods need to be employed and at what locations.

REVIEWER'S NOTE---------------------------------------- Plants are to include the appropriate Frequency (e.g., select the appropriate Item 2.) for their SG design. The first Item 2 is applicable to SGs with Alloy 600 mill annealed tubing. The second Item 2 is applicable to SGs with Alloy 600 thermally treated tubing. The third Item 2 is applicable to SGs with Alloy 690 thermally treated tubing. ------------------------------------------------------------------------------------------------------------

1. Inspect 100% of the tubes in each SG during the first refueling outage following SG installation replacement.

[2. After the first refueling outage following SG installation, inspect each steam generator at least every 24 effective full power months or at least every refueling outage (whichever results in more frequent inspections). In addition, inspect 100% of the tubes at sequential periods of 60 effective full power months beginning after the first refueling outage inspection following SG installation. Each 60 effective full power month inspection period may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage. If a degradation assessment indicates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a Programs and Manuals 5.5 CEOG STS 5.5-8 Rev. 3.1, 12/01/05 capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. Inspect 100% of the tubes at sequential periods of 60 effective full power months. The first sequential period shall be considered to begin after the first inservice inspection of the SGs. No SG shall operate for more than 24 effective full power months or one refueling outage (whichever is less) without being inspected.]

[2. After the first refueling outage following SG installation, inspect each SG at least every 48 effective full power months or at least every other refueling outage (whichever results in more frequent inspections). In addition, the minimum number of tubes inspected at each scheduled inspection shall be the number of tubes in all SGs divided by the number of SG inspection outages scheduled in each inspection period as defined in a, b, and c below. If a degradation assessment indicates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. Each inspection period defined below may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage.


Reviewer's Note ------------------------------------

A licensee may elect to retain historical and existing inspection period lengths in order to not revise those inspection periods.


a) After the first refueling outage following SG installation, inspect 100% of the tubes during the next 120 effective full power months. This constitutes the first inspection period; b) During the next 96 effective full power months, inspect 100% of the tubes. This constitutes the second inspection period; and

Programs and Manuals 5.5 CEOG STS 5.5-9 Rev. 3.1, 12/01/05 c) During the remaining life of the SGs, inspect 100% of the tubes every 72 effective full power months. This constitutes the third and subsequent inspection periods.

Inspect 100% of the tubes at sequential periods of 120, 90, and, thereafter, 60 effective full power months. The first sequential period shall be considered to begin after the first inservice inspection of the SGs. In addition, inspect 50% of the tubes by the refueling outage nearest the midpoint of the period and the remaining 50% by the refueling outage nearest the end of the period. No SG shall operate for more than 48 effective full power months or two refueling outages (whichever is less) without being inspected.]

Programs and Manuals 5.5 CEOG STS 5.5-10 Rev. 3.1, 12/01/05 5.5 Programs and Manuals

5.5.9 Steam

Generator (SG) Program (continued)

[2. After the first refueling outage following SG installation, inspect each SG at least every 72 effective full power months or at least every third refueling outage (whichever results in more frequent inspections). In addition, the minimum number of tubes inspected at each scheduled inspection shall be the number of tubes in all SGs divided by the number of SG inspection outages scheduled in each inspection period as defined in a, b, c and d below. If a degradation assessment indicates the potential for a type of degradation to occur at a location not previously inspected with a technique capable of detecting this type of degradation at this location and that may satisfy the applicable tube repair criteria, the minimum number of locations inspected with such a capable inspection technique during the remainder of the inspection period may be prorated. The fraction of locations to be inspected for this potential type of degradation at this location at the end of the inspection period shall be no less than the ratio of the number of times the SG is scheduled to be inspected in the inspection period after the determination that a new form of degradation could potentially be occurring at this location divided by the total number of times the SG is scheduled to be inspected in the inspection period. Each inspection period defined below may be extended up to 3 effective full power months to include a SG inspection outage in an inspection period and the subsequent inspection period begins at the conclusion of the included SG inspection outage.


Reviewer's Note ------------------------------------

A licensee may elect to retain historical and existing inspection period lengths in order to not revise those inspection periods.


a) After the first refueling outage following SG installation, inspect 100% of the tubes during the next 144 effective full power months. This constitutes the first inspection period; b) During the next 120 effective full power months, inspect 100% of the tubes. This constitutes the second inspection period; c) During the next 96 effective full power months, inspect 100% of the tubes. This constitutes the third inspection period; and d) During the remaining life of the SGs, inspect 100% of the tubes every 72 effective full power months. This constitutes the fourth and subsequent inspection periods.

Inspect 100% of the tubes at sequential periods of 144, 108, 72, and, thereafter, 60 effective full power months. The first sequential period shall be considered to begin after the first inservice inspection of the Programs and Manuals 5.5 CEOG STS 5.5-11 Rev. 3.1, 12/01/05 SGs. In addition, inspect 50% of the tubes by the refueling outage nearest the midpoint of the period and the remaining 50% by the refueling outage nearest the end of the period. No SG shall operate for more than 72 effective full power months or three refueling ou tages (whichever is less) without being inspected.]

3. If crack indications are found in any SG tube, then the next inspection for each affected and potentially affected SG for the degradation mechanism that caused the crack indication shall not exceed 24 effective full power months or one refueling outage (whichever results in more frequent inspectionsis less). If definitive information, such as from examination of a pulled tube, diagnostic non-destructive testing, or engineering evaluation indicates that a crack-like indication is not associated with a crack(s), then the indication need not be treated as a crack.
e. Provisions for monitoring operational primary to secondary LEAKAGE.

[f. Provisions for SG tube repair methods. Steam generator tube repair methods shall provide the means to reestablish the RCS pressure boundary integrity of SG tubes without removing the tube from service. For the purposes of these Specifications, tube plugging is not a repair. All acceptable tube repair methods are listed below.


REVIEWER'S NOTE---------------------------------------- Tube repair methods currently permitted by plant technical specifications are to be listed here. The description of these tube repair methods should be equivalent to the descriptions in current technical specifications. If there are no approved tube repair methods, this section should not be used.


1. . . .]

5.5.10 Secondary Water Chemistry Program

This program provides controls for monitoring secondary water chemistry to inhibit SG tube degradation and low pressure turbine disc stress corrosion cracking. The program shall include:

a. Identification of a sampling schedule for the critical variables and control points for these variables, Reporting Requirements 5.6 CEOG STS 5.6-4 Rev. 3.1, 12/01/05 5.6 Reporting Requirements

5.6.5 Post Accident Monitoring Report

When a report is required by Condition B or F of LCO 3.3.[11], "Post Accident Monitoring (PAM) Instrumentation," a report shall be submitted within the following 14 days. The report shall outline the preplanned alternate method of monitoring, the cause of the inoperability, and the plans and schedule for restoring the instrumentation channels of the Function to OPERABLE status.

5.6.6 Tendon

Surveillance Report

[ Any abnormal degradation of the containment structure detected during the tests required by the Pre-stressed Concrete Containment Tendon Surveillance Program shall be reported to the NRC within 30 days. The report shall include a description of the tendon condition, the condition of the concrete (especially at tendon anchorages), the inspection procedures, the tolerances on cracking, and the corrective action taken. ]

5.6.7 Steam

Generator Tube Inspection Report A report shall be submitted within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.9, "Steam Generator (SG) Program." The report shall include:

a. The scope of inspections performed on each SG, b. Active D degradation mechanisms found,
c. Nondestructive examination techniques utilized for each degradation mechanism, d. Location, orientation (if linear), and measured sizes (if available) of service induced indications, e. Number of tubes plugged [or repaired] during the inspection outage for each active degradation mechanism,
f. The number and percentage of tubes plugged [or repaired] to date, and the effective plugging percentage in each steam generatorTotal number and percentage of tubes plugged [or repaired] to date ,
g. The results of condition monitoring, including the results of tube pulls and in-situ testing,

[h. The effective plugging percentage for all plugging [and tube repairs] in each SG, and] [h i. Repair method utilized and the number of tubes repaired by each repair method.]

SG Tube Integrity B 3.4.18 CEOG STS B 3.4.18-2 Rev. 3.1, 12/01/05 BASES

APPLICABLE The steam generator tube rupture (SGTR) accident is the limiting design SAFETY basis event for SG tubes and avoiding an SGTR is the basis for this ANALYSES Specification. The analysis of a SGTR event assumes a bounding primary to secondary LEAKAGE rate equal to the operational LEAKAGE rate limits in LCO 3.4.13, "RCS Operational LEAKAGE," plus the leakage rate associated with a double-ended rupture of a single tube. The accident analysis for a SGTR assumes the contaminated secondary fluid is only briefly released to the atmosphere via safety valves and the majority is discharged to the main condenser.

The analysis for design basis accidents and transients other than a SGTR assume the SG tubes retain their structural integrity (i.e., they are assumed not to rupture.) In these analyses, the steam discharge to the atmosphere is based on the total primary to secondary LEAKAGE from all SGs of [1 gallon per minute] or is assumed to increase to [1 gallon per minute] as a result of accident induced conditions. For accidents that do not involve fuel damage, the primary coolant activity level of DOSE EQUIVALENT I-131 is assumed to be equal to the LCO 3.4.16, "RCS Specific Activity," limits. For accidents that assume fuel damage, the primary coolant activity is a function of the amount of activity released from the damaged fuel. The dose consequences of these events are

within the limits of GDC 19 (Ref. 2), 10 CFR 100 (Ref. 3) or the NRC

approved licensing basis (e.g., a small fraction of these limits).

Steam generator tube integrity satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii).

LCO The LCO requires that SG tube integrity be maintained. The LCO also requires that all SG tubes that satisfy the plugging [or repair] criteria be plugged [or repaired] in accordance with the Steam Generator Program.

During an SG inspection, any inspected tube that satisfies the Steam

Generator Program plugging [or repair] criteria is [repaired or] removed from service by plugging. If a tube was determined to satisfy the plugging [or repair criteria

] but was not plugged [or repaired], the tube may still have tube integrity.

In the context of this Specification, a SG tube is defined as the entire length of the tube, including the tube wall [and any repairs made to it],

between the tube-to-tubesheet weld at the tube inlet and the tube-to-tubesheet weld at the tube outlet. The tube-to-tubesheet weld is not considered part of the tube.

A SG tube has tube integrity when it satisfies the SG performance criteria.

The SG performance criteria are defined in Specification 5.5.9, "Steam Generator Program," and describe acceptable SG tube performance. The Steam Generator Program also pr ovides the evaluation process for determining conformance with the SG performance criteria.

SG Tube Integrity B 3.4.18 CEOG STS B 3.4.18-4 Rev. 3.1, 12/01/05 BASES

LCO (continued)

The operational LEAKAGE performance criterion provides an observable indication of SG tube conditions during plant operation. The limit on operational LEAKAGE is contained in LCO 3.4.13, "RCS Operational LEAKAGE," and limits primary to secondary LEAKAGE through any one SG to 150 gallons per day. This limit is based on the assumption that a single crack leaking this amount would not propagate to a SGTR under the stress conditions of a LOCA or a main steam line break. If this amount of LEAKAGE is due to more than one crack, the cracks are very small, and the above assumption is conservative.

APPLICABILITY Steam generator tube integrity is challenged when the pressure differential across the tubes is large. Large differential pressures across SG tubes can only be experienced in MODE 1, 2, 3, or 4.

RCS conditions are far less challenging in MODES 5 and 6 than during MODES 1, 2, 3, and 4. In MODES 5 and 6, primary to secondary differential pressure is low, resulting in lower stresses and reduced potential for LEAKAGE.

ACTIONS The ACTIONS are modified by a Note clarifying that the Conditions may be entered independently for each SG tube. This is acceptable because the Required Actions provide appropriate compensatory actions for each affected SG tube. Complying with the Required Actions may allow for continued operation, and subsequent affected SG tubes are governed by subsequent Condition entry and application of associated Required Actions.

A.1 and A.2 Condition A applies if it is discovered that one or more SG tubes examined in an inservice inspection satisfy the tube plugging [or repair] criteria but were not plugged [or repaired] in accordance with the Steam Generator Program as required by SR 3.4.18.2. An evaluation of SG tube integrity of the affected tube(s) must be made. Steam generator tube integrity is based on meeting the SG performance criteria described in the Steam Generator Program. The SG plugging [or repair ]criteria define limits on SG tube degradation that allow for flaw growth between inspections while still providing assurance that the SG performance criteria will continue to be met. In order to determine if a SG tube that should have been plugged [or repaired] has tube integrity, an evaluation must be completed that demonstrates that the SG performance criteria will continue to be met until the next refueling outage or SG tube inspection. The tube integrity SG Tube Integrity B 3.4.18 CEOG STS B 3.4.18-6 Rev. 3.1, 12/01/05 BASES

SURVEILLANCE REQUIREMENTS (continued)

The Steam Generator Program determines the scope of the inspection and the methods used to determine whether the tubes contain flaws satisfying the tube plugging [or repair] criteria. Inspection scope (i.e., which tubes or areas of tubing within the SG are to be inspected) is a function of existing and potential degradation locations. The Steam Generator Program also specifies the inspection methods to be used to find potential degradation. Inspection methods are a function of degradation morphology, non-destructive examination (NDE) technique capabilities, and inspection locations.

The Steam Generator Program defines the Frequency of SR 3.4.18.1. The Frequency is determined by the operational assessment and other limits in the SG examination guidelines (Ref. 6). The Steam Generator Program uses information on existing degradations and growth rates to determine an inspection Frequency that provides reasonable assurance that the tubing will meet the SG performance criteria at the next scheduled inspection. In addition, Specification 5.5.9 contains prescriptive requirements concerning inspection intervals to provide added assurance that the SG performance criteria will be met between scheduled inspections. If crack indications are found in any SG tube, the maximum inspection interval for all affected and potentially affected SGs is restricted by Specification 5.5.9 until subsequent inspections support extending the inspection interval.

SR 3.4.18.2

During an SG inspection, any inspected tube that satisfies the Steam Generator Program plugging [or repair] criteria is [repaired or] removed from service by plugging. The tube plugging [or repair] criteria delineated in Specification 5.5.9 are intended to ensure that tubes accepted for continued service satisfy the SG performance criteria with allowance for error in the flaw size measurement and for future flaw growth. In addition, the tube plugging [or repair] criteria, in conjunction with other elements of the Steam Generator Program, ensure that the SG performance criteria will continue to be met until the next inspection of the subject tube(s).

Reference 1 provides guidance for performing operational assessments to verify that the tubes remaining in service will continue to meet the SG performance criteria.

[Steam generator tube repairs are only performed using approved repair methods as described in the Steam Generator Program.]

The Frequency of prior to entering MODE 4 following a SG inspection ensures that the Surveillance has been completed and all tubes meeting SG Tube Integrity B 3.4.18 CEOG STS B 3.4.18-7 Rev. 3.1, 12/01/05 the plugging [or repair] criteria are plugged [or repaired] prior to subjecting the SG tubes to significant primary to secondary pressure differential.

TSTF-5 10, Rev. 2 Attachment 1 Model Application for Adoption of TSTF-510 TSTF-5 10, Rev. 2 Page 1 [DATE] 10 CFR 50.90

ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

PLANT NAME DOCKET NO. 50-[xxx] Application to Revise Technical Specifications to Adopt TSTF-510, "Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection," Using The Consolidated Line Item Improvement Process

Dear Sir or Madam:

Pursuant to 10 CFR 50.90, [LICENSEE] is submitting a request for an amendment to the Technical Specifications (TS) for [PLANT NAME, UNIT NOS.].

The proposed amendment would modify TS requirements regarding steam generator tube inspections and reporting as described in TSTF-510, Revision , "Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection." provides a description and assessment of the proposed changes, the requested confirmation of applicability, and plant-specific verifications. Attachment 2 provides the existing TS pages marked up to show the proposed changes. [Attachment 3 provides revised (clean) TS pages.] Attachment [4] provides existing TS Bases pages marked up to show the proposed changes.

Approval of the proposed amendment is requested by [date]. Once approved, the amendment shall be implemented within [ ] days.

In accordance with 10 CFR 50.91, a copy of this application, with attachments, is being provided to the designated [STATE] Official.

TSTF-5 10, Rev. 2 Page 2 [In accordance with 10 CFR 50.30(b), a license amendment request must be executed in a signed original under oath or affirmation. This can be accomplished by attaching a notarized affidavit confirming the signature authority of the signatory, or by including the following statement in the cover letter: "I declare under penalty of perjury that the foregoing is true and correct. Executed on (date)." The alternative statement is pursuant to 28 USC 1746. It does not require notarization.]

If you should have any questions regarding this submittal, please contact [NAME, TELEPHONE NUMBER]. Sincerely,

[Name, Title]

Attachments: 1. Description and Assessment

2. Proposed Technical Specification Changes (Mark-Up) 3. Revised Technical Specification Pages
4. Proposed Technical Specification Bases Changes (Mark

-Up)

cc: NRC Project Manager NRC Regional Office NRC Resident Inspector State Contact

TSTF-5 10, Rev. 2 Page 3 ATTACHMENT 1 - DESCRIPTION AND ASSESSMENT

1.0 DESCRIPTION

The proposed change revises Specification 5.5.9, "Steam Generator (SG) Program" and 5.6.7, "Steam Generator Tube Inspection Report." The proposed changes are needed to address implementation issues associated with the inspection periods, and address other administrative changes and clarifications.

The proposed amendment is consistent with TSTF-510, Revision , "Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection."

2.0 ASSESSMENT

2.1 Applicability

of Published Safety Evaluation

[LICENSEE] has reviewed TSTF-510, Revision , "Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection," and the model safety evaluation dated [DATE] as part of the Federal Register Notice for Comment. [As described in the subsequent paragraphs, ][LICENSEE] has concluded that the justifications presented in

TSTF-510 and the model safety evaluation prepared by the NRC staff are applicable to

[PLANT, UNIT NOS.] and justify this amendment for the incorporation of the changes to the

[PLANT] TS.

2.2 Optional

Changes and Variations

[LICENSEE is not proposing any variations or deviations from the TS changes described in the TSTF-510, Revision , or the applicable parts of the NRC staff's model safety evaluation dated [DATE].] [LICENSEE is proposing the following variations from the TS changes described in the TSTF-510, Revision , or the applicable parts of the NRC staff's model safety evaluation dated [DATE

].]

[The [PLANT] TS utilize different [numbering][and][titles] than the Standard Technical Specifications on which TSTF-510 was based. Specifically, [describe differences between the pla nt-specific TS numbering and/or titles and the TSTF-510 numbering and titles.] These differences are administrative and do not affect the applicability of TSTF-510 to the [PLANT] TS.]

3.0 REGULATORY

ANALYSIS 3.1 No Significant Hazards Consideration Determination

[PLANT NAME, UNIT NOS.] requests adoption of an approved change to the standard technical specifications (STS) into the plant specific technical specifications (TS), to revise the Specification 5.5.9, "Steam Generator (SG) Program," 5.6.7, "Steam Generator Tube TSTF-5 10, Rev. 2 Page 4 Inspection Report," and LCO [3.4.20], "Steam Generator Tube Integrity," to address inspection period s and other administrative changes and clarifications.

As required by 10 CFR 50.91(a), an analysis of the issue of no significant hazard s

consideration is presented below:

1. Does the proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?

Response: No.

The proposed change revises the Steam Generator (SG) Program to modify the frequency of verification of SG tube integrity and SG tube sample selection. A steam generator tube rupture (SGTR) event is one of the design basis accidents that are analyzed as part of a plant's licensing basis. The proposed SG tube inspection frequency and sample selection criteria will continue to ensure that the SG tubes are inspected such that the probability of a SGTR is not increased. The consequences of a SGTR are bounded by the conservative assumptions in the design basis accident analysis. The proposed change will not cause the consequences of a SGTR to exceed those assumptions. Therefore, it is concluded that this change does not involve a significant increase in the probability or consequences of an accident previously evaluated.

2. Does the proposed change create the possibility of a new or different kind of accident from any accident previously evaluated? Response: No.

The proposed changes to the Steam Generator Program will not introduce any adverse changes to the plant design basis or postulated accidents resulting from potential tube degradation. The proposed change does not affect the design of the SGs or their method of operation. In addition, the proposed change does not impact any other plant system or component.

Therefore, it is concluded that this change does not create the possibility of a new or different kind of accident from any accident previously evaluated.

3. Does the proposed change involve a significant reduction in a margin of safety? Response: No. The SG tubes in pressurized water reactors are an integral part of the reactor coolant pressure boundary and, as such, are relied upon to maintain the primary system's pressure and inventory. As part of the reactor coolant pressure boundary, the SG tubes are unique in that they are also relied upon as a heat transfer surface between the primary and secondary systems such that residual heat can be removed from the primary system. In addition, the SG tubes also isolate the radioactive fission products in the primary coolant from the secondary system. In summary, the safety function of a SG is maintained by ensuring the integrity of its tubes.

TSTF-5 10, Rev. 2 Page 5 Steam generator tube integrity is a function of the design, environment, and the physical condition of the tube. The proposed change does not affect tube design or operating environment. The proposed change will continue to require monitoring of the physical condition of the SG tubes such that there will not be a reduction in the margin of safety compared to the current requirements. Therefore, it is concluded that the proposed change does not involve a significant reduction in a margin of safety. Based on the above, [LICENSEE] concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.

4.0 ENVIRONMENTAL

EVALUATION The proposed change would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluent that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure.

Accordingly, the proposed change meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.