Draft Table 1 of TSTF-505, Revision 2, Affected Technical Specifications
ML17290A097
Person / Time
Site: Technical Specifications Task Force
Issue date: 06/14/2011
From:
Office of Nuclear Reactor Regulation
To:
Technical Specifications Task Force
Honcharik M
Shared Package
ML17290A003 List:
References
TSTF-505, Rev 2
Download: ML17290A097 (8)


Text

TABLE 1 AFFECTED TECHNICAL SPECIFCATIONS Action Number TS Title Applicable NUREG Action Description 1.3 Completion Times NUREG(s)- 1430 Only 5.5.18 Risk Informed Completion Time Program NUREG(s)- 1430 Only Action 3.3.1.B.1 RPS Instrumentation NUREG(s)- 1430 Only Two channels inoperable.

Action 3.3.11.A.2 EFIC System Instrumentation NUREG(s)- 1430 Only One or more EFW Initiation, Main Steam Line Isolation, or MFW Isolation Functions listed in Table 3.3.11-1 with one channel inoperable.

Action 3.3.11.B.2 EFIC System Instrumentation NUREG(s)- 1430 Only One or more EFW Initiation, Main Steam Line Isolation, or MFW Isolation Functions listed in Table 3.3.11-1 with two channels inoperable.

Action 3.3.11.B.3 EFIC System Instrumentation NUREG(s)- 1430 Only One or more EFW Initiation, Main Steam Line Isolation, or MFW Isolation Functions listed in Table 3.3.11-1 with two channels inoperable.

Action 3.3.11.C EFIC System Instrumentation NUREG(s)- 1430 Only One EFW Vector Valve Control channel inoperable.

Action 3.3.12.A EFIC Manual Initiation NUREG(s)- 1430 Only One or more EFIC Function(s) with one or both manual initiation switches inoperable in one actuation channel.

Action 3.3.13.A EFIC Logic NUREG(s)- 1430 Only One or more channel A(B) Functions inoperable with all channel B(A)

Functions OPERABLE.

Action 3.3.14.A EFIC-EFW-Vector Valve Logic NUREG(s)- 1430 Only One vector valve logic channel inoperable.

Action 3.3.5.A ESFAS Instrumentation NUREG(s)- 1430 Only One or more paramters with one channel inoperable.

Action 3.3.6.A ESFAS Manual Initiation NUREG(s)- 1430 Only One or more ESFAS Functions with one channel inoperable.

Action 3.3.8.A EDG LOPS NUREG(s)- 1430 Only One or more Functions with one channel per EDG inoperable.

Action 3.4.5.A RCS Loops - MODE 3 NUREG(s)- 1430 Only One RCS loop inoperable.

Action 3.5.2.A ECCS - Operating NUREG(s)- 1430 Only One LPCI subsystem inoperable.

Action 3.6.3.A Containment Isolation Valves NUREG(s)- 1430 Only One or more penetration flow paths with one containment isolation valve inoperable (for paths with two or more isolation valves).

Action 3.6.3.C Containment Isolation Valves NUREG(s)- 1430 Only One or more penetration flow paths with one containment isolation valve inoperable (for paths with one isolation valve and a closed system).

Action 3.7.4.A AVVs NUREG(s)- 1430 Only One required AVV [line] inoperable.

Action 3.7.5.A EFW System NUREG(s)- 1430 Only One steam supply to turbine driven EFW pump inoperable or one turbine driven EFW pump inoperable in Mode 3 following Refueling.

Action 3.7.5.B EFW System NUREG(s)- 1430 Only One EFW train inoperable [for reasons other than Conidtion A] in Mode 1, 2, or 3.

This Table contains the Conditions within the scope of TSTF-505, Revision 2. These Conditions are eligible for inclusion in the Risk Informed Completion Time Program.

NOTE: The Action Numbers are in reference to Revision 3 of the STS NUREGs

2 of 9 Action Number TS Title Applicable NUREG Action Description Action 3.7.7.A CCW System NUREG(s)- 1430 Only One CCW train inoperable.

Action 3.7.8.A SWS System NUREG(s)- 1430 Only One SWS train inoperable.

Action 3.7.9.A UHS NUREG(s)- 1430 Only

[One or more cooling towers with one cooling tower fan inoperable.]

Action 3.8.1.A.3 AC Sources - Operating NUREG(s)- 1430 Only One [required] offsite circuit inoperable.

Action 3.8.1.B.4 AC Sources - Operating NUREG(s)- 1430 Only One [required] DG inoperable.

Action 3.8.1.C.2 AC Sources - Operating NUREG(s)- 1430 Only Two [required] offsite circuits inoperable.

Action 3.8.1.D AC Sources - Operating NUREG(s)- 1430 Only One [required] offsite circuit inoperable and one [required] DG inoperable.

Action 3.8.1.F AC Sources - Operating NUREG(s)- 1430 Only One [required][automatic loac sequencer] inoperable.

Action 3.8.4.A.3 DC Sources - Operating NUREG(s)- 1430 Only One [or two] battery charger[s on one train] inoperable.

Action 3.8.4.B DC Sources - Operating NUREG(s)- 1430 Only One [or two] batter[y][ies on one train] inoperable.

Action 3.8.4.C DC Sources - Operating NUREG(s)- 1430 Only One DC electrical power subsystem inoperable for reasons other than Condition A [or B].

Action 3.8.7.A Inverters - Operating NUREG(s)- 1430 Only One [required] inverter inoperable.

Action 3.8.9.A Distribution Systems - Operating NUREG(s)- 1430 Only One or more AC electrical power distribution subsystems inoperable.

Action 3.8.9.B Distribution Systems - Operating NUREG(s)- 1430 Only One or more AC vital buses inoperable.

Action 3.8.9.C Distribution Systems - Operating NUREG(s)- 1430 Only One or more DC electrical power distribution subsystems inoperable.

1.3 Completion Times NUREG(s)- 1431 Only 5.5.18 Risk Informed Completion Time Program NUREG(s)- 1431 Only Action 3.3.1.B RTS Instrumentation NUREG(s)- 1431 Only One Manual Reactor Trip channel Inoperable Action 3.3.1.C RTS Instrumentation NUREG(s)- 1431 Only One channel or train inoperable Action 3.3.1.E RTS Instrumentation NUREG(s)- 1431 Only One channel inoperable.

Action 3.3.1.J RTS Instrumentation NUREG(s)- 1431 Only One Source Range Neutron Flux channel inoperable.

Action 3.3.1.K RTS Instrumentation NUREG(s)- 1431 Only One channel inoperable.

Action 3.3.1.N RTS Instrumentation NUREG(s)- 1431 Only One Turbine Trip channel inoperable.

Action 3.3.1.O RTS Instrumentation NUREG(s)- 1431 Only One train inoperable.

Action 3.3.1.Q RTS Instrumentation NUREG(s)- 1431 Only One or more channels inoperable.

Action 3.3.1.S RTS Instrumentation NUREG(s)- 1431 Only One trip mechanism inoperable for one RTB.

Action 3.3.2.B ESFAS Instrumentation NUREG(s)- 1431 Only One channel or train inoperable Action 3.3.2.C ESFAS Instrumentation NUREG(s)- 1431 Only One train inoperable.

Action 3.3.2.D ESFAS Instrumentation NUREG(s)- 1431 Only One channel inoperable.

Action 3.3.2.E ESFAS Instrumentation NUREG(s)- 1431 Only One Containment Pressure channel inoperable.

Action 3.3.2.F ESFAS Instrumentation NUREG(s)- 1431 Only One channel or train inoperable.

Action 3.3.2.G ESFAS Instrumentation NUREG(s)- 1431 Only One train inoperable.

3 of 9 Action Number TS Title Applicable NUREG Action Description Action 3.3.2.H ESFAS Instrumentation NUREG(s)- 1431 Only One train inoperable.

Action 3.3.2.I ESFAS Instrumentation NUREG(s)- 1431 Only One channel inoperable.

Action 3.3.2.J ESFAS Instrumentation NUREG(s)- 1431 Only One Main Feedwater Pumps trip channel inoperable.

Action 3.3.2.L ESFAS Instrumentation NUREG(s)- 1431 Only One or more channels inoperable.

Action 3.3.5.A LOP DG Start Instrumentation NUREG(s)- 1431 Only One or more Functions with one channel per bus inoperable.

Action 3.4.11.B.3 Pressurizer PORVs NUREG(s)- 1431 Only One [or two] PORV[s] inoperable an not capable of being manually cycled Action 3.4.11.C.2 Pressurizer PORVs NUREG(s)- 1431 Only One [or two] block valves(s) inoperable.

Action 3.4.5.A RCS Loops - MODE 3 NUREG(s)- 1431 Only One required RCS loop inoperable.

Action 3.4.5.C RCS Loops - MODE 3 NUREG(s)- 1431 Only

[One required RCS loop not in operation with Rod control System capable of rod withdrawal.]

Action 3.6.10.A HIS (Ice Condenser)

NUREG(s)- 1431 Only One HIS train inoperable.

Action 3.6.10.B HIS (Ice Condenser)

NUREG(s)- 1431 Only One containment region with no OPERABLE hydrogen ignitor.

Action 3.6.14.A ARS (Ice Condenser)

NUREG(s)- 1431 Only One ARS train inoperalbe.

Action 3.6.16.B.2 Ice Condenser Doors (Ice Condenser)

NUREG(s)- 1431 Only One or more ice condenser doors inoperable for reasons other than condition A or not closed.

Action 3.6.17.A Divider Barrier Integrity (Ice Condenser)

NUREG(s)- 1431 Only Action 3.6.3.A Containment Isolation Valves (Atmospheric, Subatmospheric, Ice Condenser, and Dual)

NUREG(s)- 1431 Only One or more penetration flow paths with one containment isolation valve inoperable (for paths with two or more isolation valves).

Action 3.6.3.C Containment Isolation Valves (Atmospheric, Subatmospheric, Ice Condenser, and Dual)

NUREG(s)- 1431 Only One or more penetration flow paths with one containment isolation valve inoperable (for paths with one isolation valve and a closed system).

Action 3.7.4.A ADVs NUREG(s)- 1431 Only One required ADV line inoperable.

Action 3.7.5.A AFW System NUREG(s)- 1431 Only One steam supply to turbine driven AFW pump inoperable or one turbine driven AFW pump inoperable in Mode 3 following Refueling.

Action 3.7.5.B AFW System NUREG(s)- 1431 Only One AFW train inoperable [for reasons other than Conidtion A] in Mode 1, 2, or 3.

Action 3.7.7.A CCW System NUREG(s)- 1431 Only One CCW train inoperable.

Action 3.7.8.A SWS NUREG(s)- 1431 Only One SWS train inoperable.

Action 3.7.9.A UHS NUREG(s)- 1431 Only

[One or more cooling towers with one cooling tower fan inoperable.]

Action 3.8.1.A.3 AC Sources - Operating NUREG(s)- 1431 Only One [required] offsite circuit inoperable.

Action 3.8.1.B.4 AC Sources - Operating NUREG(s)- 1431 Only One [required] DG inoperable.

Action 3.8.1.C.2 AC Sources - Operating NUREG(s)- 1431 Only Two [required] offsite circuits inoperable.

Action 3.8.1.D AC Sources - Operating NUREG(s)- 1431 Only One [required] offsite circuit inoperable and one [required] DG inoperable.

Action 3.8.1.F AC Sources - Operating NUREG(s)- 1431 Only One [required][automatic loac sequencer] inoperable.

Action 3.8.4.A.3 DC Sources - Operating NUREG(s)- 1431 Only One [or two] battery charger[s on one train] inoperable.

4 of 9 Action Number TS Title Applicable NUREG Action Description Action 3.8.4.B DC Sources - Operating NUREG(s)- 1431 Only One [or two] batter[y][ies on one train] inoperable.

Action 3.8.4.C DC Sources - Operating NUREG(s)- 1431 Only One DC electrical power subsystem inoperable for reasons other than Condition A [or B].

Action 3.8.7.A Inverters - Operating NUREG(s)- 1431 Only One [required] inverter inoperable.

Action 3.8.9.A Distribution Systems - Operating NUREG(s)- 1431 Only One or more AC electrical power distribution subsystems inoperable.

Action 3.8.9.B Distribution Systems - Operating NUREG(s)- 1431 Only One or more AC vital buses inoperable.

Action 3.8.9.C Distribution Systems - Operating NUREG(s)- 1431 Only One or more DC electrical power distribution subsystems inoperable.

1.3 Completion Times NUREG(s)- 1432 Only 5.5.18 Risk Informed Completion Time Program NUREG(s)- 1432 Only Action 3.3.1.A.2.1 RPS Instrumentation - Operating (Analog)

NUREG(s)- 1432 Only One or more Functions with one RPS trip unit or associated instrument achannel inoperalb eexcept for Condition C Action 3.3.1.A.2.2 RPS Instrumentation - Operating (Analog)

NUREG(s)- 1432 Only One or more Functions with one RPS trip unit or associated instrument channel inoperalbe except for Condition C Action 3.3.1.B.2 RPS Instrumentation - Operating (Analog)

NUREG(s)- 1432 Only One or more Functions with two RPS trip units or associated instrument channel inoperalbe except for Condition C Action 3.3.1.D.2.2.1 RPS Instrumentation - Operating (Analog)

NUREG(s)- 1432 Only One or more functions with one automatic bypass removal channel inoperable.

Action 3.3.1.D.2.2.2 RPS Instrumentation - Operating (Analog)

NUREG(s)- 1432 Only One or more functions with one automatic bypass removal channel inoperable.

Action 3.3.1.E.2.2 RPS Instrumentation - Operating (Analog)

NUREG(s)- 1432 Only One or more Functions with two automatic bypass removal channels inoperable.

Action 3.3.4.A RPS Logic and Trip Initiation (Analog)

NUREG(s)- 1432 Only One Matrix Logic channel inoperable or Three Matrix Logic channels inoperable due to a common power source failure.

Action 3.3.5.A ESFAS Logic and Manual Trip (Analog)

NUREG(s)- 1432 Only One or more Functions with one Auxiliary Feedwater Acutation Signal (AFAS) Manual Trip or Actuation Logic channel inoperable.

Action 3.3.5.C ESFAS Logic and Manual Trip (Analog)

NUREG(s)- 1432 Only One or more Functions with one Manual Trip or Actuation Logic channel inoperalbe except AFAS.

Action 3.3.6.A.2.1 DG LOVS (Analog)

NUREG(s)- 1432 Only One or more Functions with one channel per DG inoperable.

Action 3.3.6.A.2.2 DG LOVS (Analog)

NUREG(s)- 1432 Only One or more Functions with one channel per DG inoperable.

Action 3.3.6.B.2.2 DG LOVS (Analog)

NUREG(s)- 1432 Only One or more Functions with two channels per DG inoperable.

Action 3.3.4.A RPS Logic and Trip Initiation (Digital)

NUREG(s)- 1432 Only One Matrix Logic channel inoperable or Three Matrix Logic channels inoperable due to a common power source failure.

Action 3.3.6.B ESFAS Logic and Manual Trip (Digital)

NUREG(s)- 1432 Only One or more Functions with one Manual Trip or Initiation Logic channel inoperable.

Action 3.3.6.D ESFAS Logic and Manual Trip (Digital)

NUREG(s)- 1432 Only One or more Functions with one Actuation Logic channel inoperable.

Action 3.4.11.B.3 Pressurizer PORVs NUREG(s)- 1432 Only One PORV inoperable and capable of being manually cycled.

Action 3.4.11.C.2 Pressurizer PORVs NUREG(s)- 1432 Only One block valve inoperable.

5 of 9 Action Number TS Title Applicable NUREG Action Description Action 3.4.5.A RCS Loops - MODE 3 NUREG(s)- 1432 Only One RCS loop inoperable.

Action 3.5.2.A ECCS - Operating NUREG(s)- 1432 Only One LPCI subsystem inoperable.

Action 3.6.3.A Containment Isolation Valves (Atmospheric and Dual)

NUREG(s)- 1432 Only One or more penetration flow paths with one containment isolation valve inoperable (for sump supply valves to ECCS and CS pumps).

Action 3.6.3.B Containment Isolation Valves (Atmospheric and Dual)

NUREG(s)- 1432 Only One or more penetration flow paths with one containment isolation valve inoperable (for paths with two or more isolation valves).

Action 3.6.3.D Containment Isolation Valves (Atmospheric and Dual)

NUREG(s)- 1432 Only One or more penetration flow paths with one containment isolation valve inoperable (for paths with one isolation valve and a closed system).

Action 3.7.10.A ECW NUREG(s)- 1432 Only One ECW train inoperable.

Action 3.7.4.A ADVs NUREG(s)- 1432 Only One required ADV line inoperable.

Action 3.7.5.A AFW System NUREG(s)- 1432 Only One steam supply to turbine driven AFW pump inoperable or one turbine driven AFW pump inoperable in Mode 3 following Refueling.

Action 3.7.5.B AFW System NUREG(s)- 1432 Only One AFW train inoperable [for reasons other than Conidtion A] in Mode 1, 2, or 3.

Action 3.7.7.A CCW System NUREG(s)- 1432 Only One CCW train inoperable.

Action 3.7.8.A SWS NUREG(s)- 1432 Only One SWS train inoperable.

Action 3.7.9.A UHS NUREG(s)- 1432 Only One or more cooling towers with one cooling tower fan inoperable.

Action 3.8.1.A.3 AC Sources - Operating NUREG(s)- 1432 Only One AC train inoperable.

Action 3.8.1.B.4 AC Sources - Operating NUREG(s)- 1432 Only One AC train inoperable.

Action 3.8.1.C.2 AC Sources - Operating NUREG(s)- 1432 Only One AC train inoperable.

Action 3.8.1.D AC Sources - Operating NUREG(s)- 1432 Only One AC train inoperable.

Action 3.8.1.F AC Sources - Operating NUREG(s)- 1432 Only One AC train inoperable.

Action 3.8.4.A.3 DC Sources - Operating NUREG(s)- 1432 Only One DC train inoperable.

Action 3.8.4.B DC Sources - Operating NUREG(s)- 1432 Only One DC train inoperable.

Action 3.8.4.C DC Sources - Operating NUREG(s)- 1432 Only One DC train inoperable.

Action 3.8.7.A Inverters - Operating NUREG(s)- 1432 Only One Inverters train inoperable.

Action 3.8.9.A Distribution Systems - Operating NUREG(s)- 1432 Only One Distribution train inoperable.

Action 3.8.9.B Distribution Systems - Operating NUREG(s)- 1432 Only One Distribution train inoperable.

Action 3.8.9.C Distribution Systems - Operating NUREG(s)- 1432 Only One Distribution train inoperable.

Action 3.3.1.A RPS Instrumentation - Operating (Analog)

NUREG(s)- 1432 Only One or more functions with one RPS trip unit or associated instrument channel inoperable except Condition C Action 3.3.1.B RPS Instrumentation - Operating (Analog)

NUREG(s)- 1432 Only One or more functions with two RPS trip units or associated instrument channel inoperable except Condition C Action 3.3.1.D RPS Instrumentation - Operating (Analog)

NUREG(s)- 1432 Only One or more Functions with one automatic bypass removal channel inoperable.

Action 3.3.1.E RPS Instrumentation - Operating (Analog)

NUREG(s)- 1432 Only One or more Functions with two automatic bypass removal channels inoperable.

6 of 9 Action Number TS Title Applicable NUREG Action Description Action 3.3.3.A RPS Logic and Trip Initiation (Analog)

NUREG(s)- 1432 Only One Matrix Logic channel inoperable OR Three Matrix Logic Channels inoperable due to a common power source failure Action 3.3.4.B ESFAS Instrumentation (Analog)

NUREG(s)- 1432 Only One or more Functions with one ESFAS trip unit or assoicated instrument channel (except CSAS) inoperable.

Action 3.3.4.C ESFAS Instrumentation (Analog)

NUREG(s)- 1432 Only One or more Functions with two ESFAS trip units or associated instrumentat channels (except CSAS) inoperable.

Action 3.3.4.D ESFAS Instrumentation (Analog)

NUREG(s)- 1432 Only One or more Functions with one automatic bypass removal channel inoperable.

Action 3.3.4.E ESFAS Instrumentation (Analog)

NUREG(s)- 1432 Only One or more Functions with two automatic bypass removal channels inoperable.

Action 3.3.5.C ESFAS Lofic and Manual Trip (Analog)

NUREG(s)- 1432 Only One or more Functions with one Manual Trip or Actuation Logic channel inoperable except AFAS.

Action 3.3.6.A DG - LOVS (Analog)

NUREG(s)- 1432 Only One or more Functions with one channel per DG inoperable.

Action 3.3.6.B DG - LOVS (Analog)

NUREG(s)- 1432 Only One or more Functions with two channels per DG inoperable.

1.3 Completion Times NUREG(s)- 1433 Only One Completion train inoperable.

5.5.15 Risk Informed Completion Time Program NUREG(s)- 1433 Only One Risk train inoperable.

Action 3.1.7.B SLC System NUREG(s)- 1433 Only One SLC subsystem inoperable (for reasons other than Condition A).

Action 3.3.1.1.A RPS Instrumentation NUREG(s)- 1433 Only One or more required channels inoperable.

Action 3.3.1.1.B RPS Instrumentation NUREG(s)- 1433 Only One or more Functions with one or more required channels inoperable in both trip systems.

Action 3.3.2.2.A Feedwater and Main Turbine High Water Level Trip Instrumentation NUREG(s)- 1433 Only One feedwater and main turbine high water level trip channel inoperable.

Action 3.3.4.2.A ATWS-RPT Instrumentation NUREG(s)- 1433 Only One or more channels inoperable.

Action 3.3.5.1.B.3 ECCS Instrumentation NUREG(s)- 1433 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.1.C.2 ECCS Instrumentation NUREG(s)- 1433 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.1.D.2.1 ECCS Instrumentation NUREG(s)- 1433 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.1.E.2 ECCS Instrumentation NUREG(s)- 1433 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.1.F.2 ECCS Instrumentation NUREG(s)- 1433 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.1.G.2 ECCS Instrumentation NUREG(s)- 1433 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.2.B.2 RCIC System Instrumentation NUREG(s)- 1433 Only As required by Required Action A.1 and referenced in Table 3.3.5.2-1.

Action 3.3.5.2.D.2.1 RCIC System Instrumentation NUREG(s)- 1433 Only As required by Required Action A.1 and referenced in Table 3.3.5.2-1.

7 of 9 Action Number TS Title Applicable NUREG Action Description Action 3.3.6.1.A Primary Containment Isolation Instrumentation NUREG(s)- 1433 Only One or more required channels inoperable.

Action 3.4.3.A S/RVs NUREG(s)- 1433 Only

[One [or two] [required] S/RVs ] inoperable.

Action 3.5.1.A ECCS - Operating NUREG(s)- 1433 Only One low pressure ECCS injection/spray subsystem inoperable or one LPCI pump in both LPCI subsystems inoperable.

Action 3.5.1.C ECCS - Operating NUREG(s)- 1433 Only HPCI system inoperable.

Action 3.5.1.D ECCS - Operating NUREG(s)- 1433 Only HPCI system inoperable and Condition A entered.

Action 3.5.1.E ECCS - Operating NUREG(s)- 1433 Only One ADS valve inoperable.

Action 3.5.1.F ECCS - Operating NUREG(s)- 1433 Only One ADS valve inoperable and Condition A entered.

Action 3.5.3.A.2 RCIC System NUREG(s)- 1433 Only RCIC system inoperable.

Action 3.6.1.3.A PCIVs NUREG(s)- 1433 Only One or more penetration flow paths with one PCIV inoperable for reasons other than Condition D or E (for paths with two [or more] PCIVs.

Action 3.6.1.7.C Reactor Building-to-Suppression Chamber Vacuum Breakers NUREG(s)- 1433 Only One line with one or more reactor building-to-suppression chamber vacuum breakers inoperable for opening.

Action 3.6.1.8.A Suppression Chamber-to-Drywell Vacuum Breakers NUREG(s)- 1433 Only One required suppression chamber-to-drywell vacuum breaker inoperable for opening.

Action 3.6.2.3.A RHR Suppression Pool Cooling NUREG(s)- 1433 Only One RHR suppression pool cooling subsystem inoperable.

Action 3.6.2.4.A RHR Suppression Pool Spray NUREG(s)- 1433 Only One RHR suppression pool spray subsystem inoperable.

Action 3.6.3.1.B.2

[Drywell Cooling system Fans]

NUREG(s)- 1433 Only Two [required] [drywell cooling system fans] inoperable.

Action 3.7.1.B RHRSW System NUREG(s)- 1433 Only One RHRSW pump in each subsystem inoperable.

Action 3.7.1.C RHRSW System NUREG(s)- 1433 Only One RHRSW subsystem inoperable for reasons other than Condition A.

Action 3.7.2.B

[PSW] System and [UHS]

NUREG(s)- 1433 Only One [PSW] pump in each subsystem inoperable.

Action 3.7.2.C

[PSW] System and [UHS]

NUREG(s)- 1433 Only

[One or more cooling towers with one cooling tower fan inoperable.].

Action 3.7.2.E

[PSW] System and [UHS]

NUREG(s)- 1433 Only One [PSW] subsystem inoperabl efor reasosn other than Condition[s] A

[and C].

Action 3.8.1.A.3 AC Sources - Operating NUREG(s)- 1433 Only One AC train inoperable.

Action 3.8.1.B.4 AC Sources - Operating NUREG(s)- 1433 Only One [required] offsite circuit inoperable.

Action 3.8.1.C.2 AC Sources - Operating NUREG(s)- 1433 Only One [required] DG inoperable.

Action 3.8.1.D AC Sources - Operating NUREG(s)- 1433 Only Two [required] offsite circuits inoperable.

Action 3.8.1.F AC Sources - Operating NUREG(s)- 1433 Only One [required] offsite circuit inoperable and one [required] DG inoperable.

Action 3.8.4.A.3 DC Sources - Operating NUREG(s)- 1433 Only One [required][automatic loac sequencer] inoperable.

Action 3.8.4.B DC Sources - Operating NUREG(s)- 1433 Only One [or two] battery charger[s on one train] inoperable.

Action 3.8.4.C DC Sources - Operating NUREG(s)- 1433 Only One [or two] batter[y][ies on one train] inoperable.

Action 3.8.7.A Inverters - Operating NUREG(s)- 1433 Only One DC electrical power subsystem inoperable for reasons other than Condition A [or B].

8 of 9 Action Number TS Title Applicable NUREG Action Description Action 3.8.9.A Distribution Systems - Operating NUREG(s)- 1433 Only One [required] inverter inoperable.

Action 3.8.9.B Distribution Systems - Operating NUREG(s)- 1433 Only One or more AC electrical power distribution subsystems inoperable.

Action 3.8.9.C Distribution Systems - Operating NUREG(s)- 1433 Only One or more AC vital buses inoperable.

1.3 Completion Times NUREG(s)- 1434 Only 5.5.15 Risk Informed Completion Time Program NUREG(s)- 1434 Only Action 3.1.7.B SLC System NUREG(s)- 1434 Only One SLC subsystem inoperable [for reasons other than Condition A]

Action 3.3.1.1.A RPS Instrumentation NUREG(s)- 1434 Only One or more required channels inoperable.

Action 3.3.1.1.B RPS Instrumentation NUREG(s)- 1434 Only One or more Functions with one or more required channels inoperable in both trip systems.

Action 3.3.4.2.A ATWS-RPT Instrumentation NUREG(s)- 1434 Only One or more channels inoperable.

Action 3.3.5.1.B.3 ECCS Instrumentation NUREG(s)- 1434 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.1.C.2 ECCS Instrumentation NUREG(s)- 1434 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.1.D.2.1 ECCS Instrumentation NUREG(s)- 1434 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.1.E.2 ECCS Instrumentation NUREG(s)- 1434 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.1.F.2 ECCS Instrumentation NUREG(s)- 1434 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.1.G.2 ECCS Instrumentation NUREG(s)- 1434 Only As required by Required Action A.1 and referenced in Table 3.3.5.1-1.

Action 3.3.5.2.B.2 RCIC System Instrumentation NUREG(s)- 1434 Only As required by Required Action A.1 and referenced in Table 3.3.5.2-1.

Action 3.3.5.2.D.2.1 RCIC System Instrumentation NUREG(s)- 1434 Only As required by Required Action A.1 and referenced in Table 3.3.5.2-1.

Action 3.3.6.1.A Primary Containment Isolation Instrumentation NUREG(s)- 1434 Only One or more required channels inoperable.

Action 3.3.6.3.B.2 RHR Containment Spray System Instrumentation NUREG(s)- 1434 Only As required by Required Action A.1 and referenced in Table 3.3.5.3-1.

Action 3.3.6.3.C.2 RHR Containment Spray System Instrumentation NUREG(s)- 1434 Only As required by Required Action A.1 and referenced in Table 3.3.5.3-1.

Action 3.4.4.A S/RVs NUREG(s)- 1434 Only

[One [required] S/RV inoperable.]

Action 3.5.1.A ECCS - Operating NUREG(s)- 1434 Only One low pressure ECCS injection/spray subsystem inoperable.

Action 3.5.1.B.2 ECCS - Operating NUREG(s)- 1434 Only High Pressure Core Spray (HPCS) System inoperable.

Action 3.5.1.C ECCS - Operating NUREG(s)- 1434 Only Two ECCS injection subsystems inoperable OR One ECCS injection and one ECCS spray subsystem inoperable.

Action 3.5.1.E ECCS - Operating NUREG(s)- 1434 Only One ADS valve inoperable.

9 of 9 Action Number TS Title Applicable NUREG Action Description Action 3.5.1.F ECCS - Operating NUREG(s)- 1434 Only One ADS valve inoperable AND One low pressure ECCS injection/spray subsystem inoperable.

Action 3.5.3.A.2 RCIC System NUREG(s)- 1434 Only RCIC System inoperable.

Action 3.6.1.3.A PCIVs NUREG(s)- 1434 Only One or more penetration flow paths with one PCIV inoperable for reasons other than Condition[s] D [and E] (for paths with two [or more] PCIVs.

Action 3.6.2.3.A RHR Suppression Pool Cooling NUREG(s)- 1434 Only One RHR suppression pool cooling subsystem inoperable.

Action 3.6.2.4.C SPMU System NUREG(s)- 1434 Only One SPMU subsystem inoperable for reasons other than Condition A or B.

Action 3.6.5.3.A.1 Drywell Isolation Valves NUREG(s)- 1434 Only One or more penetration flow paths with one drywell isolation valve inoperable.

Action 3.7.1.A

[SSW] System and [UHS]

NUREG(s)- 1434 Only

[One or more cooling towers with one cooling tower fan inoperable.]

Action 3.7.1.C

[SSW] System and [UHS]

NUREG(s)- 1434 Only One [SSW] subsystem inoperable [for reasons other than Condition A].

Action 3.8.1.A.3 AC Sources - Operating NUREG(s)- 1434 Only One [required] offsite circuit inoperable.

Action 3.8.1.B.4 AC Sources - Operating NUREG(s)- 1434 Only One [required] DG inoperable.

Action 3.8.1.C.2 AC Sources - Operating NUREG(s)- 1434 Only Two [required] offsite circuits inoperable.

Action 3.8.1.D AC Sources - Operating NUREG(s)- 1434 Only One [required] offsite circuit inoperable and one [required] DG inoperable.

Action 3.8.1.F AC Sources - Operating NUREG(s)- 1434 Only One [required][automatic loac sequencer] inoperable.

Action 3.8.4.A.3 DC Sources - Operating NUREG(s)- 1434 Only One [or two] battery charger[s on one train] inoperable.

Action 3.8.4.B DC Sources - Operating NUREG(s)- 1434 Only One [or two] batter[y][ies on one train] inoperable.

Action 3.8.4.C DC Sources - Operating NUREG(s)- 1434 Only One DC electrical power subsystem inoperable for reasons other than Condition A [or B].

Action 3.8.7.A Inverters - Operating NUREG(s)- 1434 Only One [required] inverter inoperable.

Action 3.8.9.A Distribution Systems - Operating NUREG(s)- 1434 Only One or more AC electrical power distribution subsystems inoperable.

Action 3.8.9.B Distribution Systems - Operating NUREG(s)- 1434 Only One or more AC vital buses inoperable.

Action 3.8.9.C Distribution Systems - Operating NUREG(s)- 1434 Only One or more DC electrical power distribution subsystems inoperable.