Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML17244A535 | 25 May 1979 | Forwards LER 79-011/01T-0 | |
ML17244A537 | 20 April 1979 | Confirms 790420 Telcon W/W Lasurus Re LER 79-10,boric Acid Storage Tanks out-of-spec for Vol & Weight.Orderly Load Reduction Initiated to Restore Tanks to Required Specs | Boric Acid |
ML17244A538 | 28 April 1979 | Responds to IE Bulletins 79-06A & 79-06A,Revision I, Review of Operational Errors & Sys Misalignments Identified During TMI-2 Incident. Plant Procedures Are Being Reviewed & Updated | Boric Acid |
ML17244A539 | 29 May 1979 | Forwards Offsite Dose Calculating Manual | |
ML17244A543 | 16 April 1979 | Confirms 790416 Telcon to W Raymond Reporting LER-79-09, Boric Acid Storage Tanks Out of Spec for Vol & Weight of Boric Acid.Orderly Load Reduction & Batching Operations Commenced;Tanks within Specs | Boric Acid |
ML17244A544 | 30 April 1979 | Forwards Response to IE Bulleitn 79-04,Incorrect Weights for Swing Valves Mfg by Velan Engineering Corp. Valves Used insafety-related Sys Are in Close Proximity to Pipe Supports.No Mods Planned | |
ML17244A546 | 25 April 1979 | Responds to IE Bulletin 79-07 Re Seismic Stress Analysis of safety-related Piping.Confirms Capability of Plant to Withstand Seismic Event | |
ML17244A556 | 14 June 1979 | Forwards Endorsements 49,50 & 51 to Maelu Policy MF-47 & Endorsements 60 & 61 of Nelia Policy NF-170 | |
ML17244A557 | 14 June 1979 | Responds to NRC 790606 Ltr Requesting Info Re Systematic Evaluation Program Topic VI-I.Suggests NRC Review Info Already Docketed,Including FSAR App 6E & Discussion of Reg Guide 1.54 in Util 731220 Ltr | |
ML17244A558 | 18 June 1979 | Forwards Addl Info Re PWR Feedwater Lines in Response to NRC 790525 request.W/3 Oversized Drawings | Hydrostatic Flow Induced Vibration |
ML17244A559 | 14 June 1979 | Notifies Replacement of Computer Room Ceiling Is Delayed Until 790831 | |
ML17244A560 | 20 June 1979 | Forwards LER 79-012/01T-0 | |
ML17244A569 | 20 June 1979 | Requests Notification of Date for Meeting W/Nrc to Discuss Computer Models Which Reflect Upper Plenum Injection of ECCS | |
ML17244A570 | 18 May 1979 | Responds to IE Bulletins 79-06A & 79-06A,Revision 1.No Tech Spec Changes Required at This Time.Change Will Be Requested When Design & Safety Evaluations Are Prepared | |
ML17244A571 | 11 May 1979 | Confirms 790510 Discussion W/D Beckman Re LER 79-011.New Valve Internals Being Mfg to Correct Problem.Will Be Available in June | |
ML17244A573 | 25 June 1979 | Notifies Revision 6 to Suppl IV of full-term License Application Will Be Submitted in Early July,As Requested by NRC 790605 Ltr.Revision 6 Will Exclude Reg Guide 1.94 from Listing of ANSI Stds | |
ML17244A575 | 27 June 1979 | Forwards Summary of Status of Mods & Insp Program Re 731101 Evaluation of OL Effects of Postulated High Energy Line Breaks Outside Containment.All Mods Completed & Inservice Insp Program Initiated | Boric Acid |
ML17244A576 | 18 May 1979 | Requests Extension to 790801 for Response to IE Bulletins 78-12A & 78-12B | |
ML17244A577 | 25 May 1979 | Responds to IE Bulletin 79-10, Requalifiction Training Program Statistics. Forwards Util Requalification Training Program Statistics | |
ML17244A580 | 29 June 1979 | Responds to Item 3.2.7 of Fire Protection Safety Evaluation Dtd 790214.Performance Tests on Two Fire Pumps Conducted on 790516.Presently Analyzing Test Methods & Instrumentation | |
ML17244A581 | 18 May 1979 | Responds to IE Bulletin 79-09.No GE Type AK-2 Circuit Breakers Installed or Planned for Use in safety-related Sys at Facility | |
ML17244A585 | 2 July 1979 | Forwards Inservice Insp Program for 1980-89 (App B of QA Manual) | |
ML17244A588 | 2 July 1979 | Responds to NRC 781129 Ltr Re Containment Purging During Normal Plant Operation.Discusses Mfg Analyses & Confirmation That Containment Isolation Valves Will Close Under Postulated Design Basis Accident | |
ML17244A589 | 12 June 1979 | Forwards Monthly Operating Rept for May 1979 | |
ML17244A601 | 6 July 1979 | Responds to 790618 Request Re Info Available to Control Room Operator to Indicate Status of Class IE Batteries,Associated Chargers & Direct Current Buses | |
ML17244A604 | 6 July 1979 | Forwards Addl Info Re Pressure Shielding Steel Diaphragm, in Response to Questions Raised During Review of Util 790517 Submittal | |
ML17244A605 | 10 July 1979 | Forwards LER 79-012/01X-1 | |
ML17244A613 | 16 July 1979 | Forwards Addl SEP Seismic Review Info Including Summary Analysis of Equipment Inside Containment,W/Tank & Foundation Drawings for Diesel Generator Air Tanks,Boric Acid Storage Tanks & Refueling Water Storage Tank.Encl in Central Files | Boric Acid Earthquake |
ML17244A691 | 1 June 1979 | Submits Addl Info to Encl B&W 790313 Response Re IE Bulletins 78-12A & 78-12B, Atypical Weld Matl in Reactor Pressure Vessel Welds. Forwards Vendor 790313 Ltr to Westinghouse.Util Maintains Requirements Met | |
ML17244A707 | 19 July 1979 | Responds to 790620 Telcon Request.Forwards NPDES & Permit Supporting Info | |
ML17244A712 | 23 July 1979 | Forwards LER 79-013/01T-0 | |
ML17244A723 | 26 July 1979 | Responds to NRC 790611 Ltr Requesting Addl Info Re Westinghouse Small Break LOCA Analysis.Relevant Westinghouse Rept Was Transmitted to NRC W/C Reed 790629 Ltr to DF Ross | |
ML17244A725 | 25 July 1979 | Confirms 790724 Telcon.Compilation of Info Re Mgt & Technical Staffs Will Be Completed by 790814 | |
ML17244A726 | 25 July 1979 | Forwards Review Fee for Safeguards Contingency Plan Submitted on 790323 | |
ML17244A732 | 27 July 1979 | Discusses Reasons for Delay from July 1979 to 791001 for Installation of Curbs in Screenhouse Around Diesel Fire Pump Area | |
ML17244A735 | 12 July 1979 | Responds to IE Bulletin 79-13, Cracking in Feedwater Sys Piping, Item 5.Feedwater Nozzle Inspected & Evaluated. Emergency Procedures Adequately Cover Feedwater Line Break Accident | |
ML17244A737 | 6 July 1979 | Responds to IE Bulletin 79-02 Re Pipe Support Base Plate Designs Using Concrete Expansion Anchor Bolts.Discusses Base Plate Flexibility,Safety Factors,Cyclical Loads & QC Documentation | Safe Shutdown |
ML17244A743 | 25 June 1979 | Responds to IE Bulletin 79-11 Re Faulty Overcurrent Trip Devices in Westinghouse Type DB-75 & DB-50 Circuit Breakers for Engineered Safety Sys.Numerous Devices Presently Installed at Plant | |
ML17244A744 | 22 June 1979 | Responds to IE Bulletins 79-06A & 06A,Revision 1, Review of Operational Errors & Sys Misalignments Identified During TMI Incident. | Boric Acid |
ML17244A750 | 7 August 1979 | Forwards LER 79-015/01T-0 | |
ML17244A752 | 10 August 1979 | Forwards Endorsement 62 to Nelia Policy NF-170 & Endorsement 52 to Maelu Policy MF-52 | |
ML17244A753 | 8 August 1979 | Forwards LER 79-014/03L-0 | |
ML17244A763 | 13 August 1979 | Forwards Monthly Operating Rept for Jul 1979 | |
ML17244A766 | 11 July 1979 | Confirms 790710 Telcon Rept Re Cracking Found in Feedwater Lines.Final Rept Will Be Submitted within 30 Days | |
ML17244A767 | 16 August 1979 | Responds to Conversation W/Nrc Re Dependence of Turbine Driven Auxiliary Feedwater Sys on Ac Power & Request to Commit to Demonstrate Operability of Sys W/O Reliance on Ac Power.Believes No Sys Changes Necessary | |
ML17244A768 | 16 August 1979 | Forwards LER 79-016/01T-0 | |
ML17244A778 | 27 July 1979 | Forwards Response to IE Bulletin 79-13 Re Cracking in Feedwater Piping.Forwards 30-day Rept on Examniation, Evaluation & Corrective Action Taken at Plant | Nondestructive Examination Liquid penetrant |
ML17244A779 | 26 July 1979 | Forwards Supplemental Response to IE Bulletin 79-02 Re Pipe Support Base Plate Designs Using Concrete Expansion Bolts. Submits Info Re Testing & Replacement Program,Base Plate Flexibility & Replacement Program | Safe Shutdown Boric Acid |
ML17244A782 | 16 August 1979 | Forwards Statement Released to Media on 790815 Re Claim Brought Against Util by Contractor Employee Claiming Injury Due to Overexposure to Radiation.Damages of $5 Million Sought | |
ML17244A785 | 24 July 1979 | Confirms Discussion W/D Beckman & R Markowsky Re 790724 Rept of LER 79-015.Pipe Supports in Containment Vessel Identified as Nonconforming to Original Design Drawings.Supports to Be Reworked to Original Design Requirements |