REGULATOhl INFORMATION DISTRIBUTION b aTEM (RIDS)

ACCESSION NBR+ 7908210090 DOC ~ DATE: 79/08/16 NOTARIZED; NO DOCKET FACIL:50-244 Robert Emmet Ginna Nuclear Plantg Unit, li Rochester G

05000244 AUTH BYNAME AUTHOR AFFILIATION HHITEeLeDe Rochester Gas L Electric Corp<

REC IP,NAME, RECIPIENT AFF ILIATION ZIEMANNgD ~ L, Operating Reactors Branch 2

SUBJECT:

Responds to conversation w/NRC re dependence of turbine driven auxiliary feedwater sys on AC power K request to

'ommit to demonstrate operability of sys w/o reliance on AC powers Believes no sys changes necessary'ISTRIBUTION GODET A001S COPIES RECEIVED;LTR g

ENCL SIZE+

TITLE: GENERAL DISTRIBUTION FOR AFTER ISSUANCE OF OPERATING LIC OTES ~ /l~

~4%lpYw ~erta~te~~w+sotRM~oa~~~~~frrgw&~IPAss~eh~oe~

<<ewoe~4fMptplwwww~laweeww~peRMIawwww~~~M RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR EN L

ID CODE/NAME LTTR ENCL ACTION:

05 BC J

INTERNAL:

0 AEG F

L 12 15 CORE PERF BR 17 ENGR BR 19 PLANT SYS BR 21 EFLT TRT SYS

OELD, EXTERNAL: 03 LPDR 23 ACRS 1

16 1

02 NRC PDR TA/EDO 16 AD SYS/PROJ 18 REAC SFTY BR 20 EEB 22 BR INKMAN 04 NSIC CCP 4/

0 TOTAL NUMBER 'OF COPIES REQUIRED:

LTTR ~

ENCI

I

'5,,

Il f

n S

S I

I(

W J

I

.S S

lI 5

l 5 '

l 5'I 1/

jj jjjjjjjjjjjj/

jjjjjjjjjjjj/

l AAro

(/f /!fig//

jll/ill/Ill//

Illistzst(ZSI j//j//j//////

ROCHESTER GAS AND ELECTRIC CORPORATION o

89 EAST AVENUE, ROCHESTER, N.Y. 14649 LEON D. WHITE, JR.

VICE PRESIDENT TELEPHONE ARE* CODE 7 la 546-2700 August 16, 1979 Director of Nuclear Reactor Regulation Attention:

Mr. Dennis L. Ziemann, Chief Operating Reactors Branch No.

2 U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Auxiliary Feedwater System R.E.

Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Ziemann:

In recent conversations with members of the NRC Staff regarding the preliminary recommendations of the "Bulletins and Orders Task Force", questions were raised concerning the dependence of the Ginna turbine driven auxiliary feedwater (TDAFW) system on AC power.

Our TDAFW pump uses service water for cooling of the turbine bearing lube oil and pump end bearing, and thus, relies on either offsite or emergency onsite AC power.

We were asked to commit to demonstrate operability of the system without any reliance on AC power or to commit to a modification which would accomplish this.

A loss of all AC power (including offsite power and both diesel generators) is not, a credible sequence of events in the Ginna accident analysis design basis.

During ten years of commercial operation at Ginna, there have been only three instances of diesel generator failure; none of these instances involved the failure of both diesel generators.

Furthermore, there have been only two loss of offsite power transients at Ginna.

During these losses of offsite power, the diesel generators have never failed to start.

It is thus apparent that the reliability of the Ginna AC systems is very high.

Without specific negative findings for Ginna, we do not find it appropriate that the Staff require Ginna to evaluate a new, very low probability, accident scenario.

P

ROCHESTER GAS AND ELECT C CORP.

oATE August 16, 1979 TO Director of Nuclear Reactor Regulation SHEET NO.

Further, it is useful to note that this loss of all AC power is an NRC Category B Generic Activity (Station Blackout-B57) for which the NRC has not yet developed analysis groundrules or acceptance criteria. It is apparent from the previous NRC effort in this area that this event is considered of sufficiently low probability that questions regarding Ginna capability to mitigate such an event do not pose any immediate danger to the health and safety of the public.

Nevertheless, based on our confidence that the Ginna TDAFW pump could operate for an acceptably long period of time without any reliance on AC power, we have performed a test to confirm this confidence.

The pump which was tested is a Worthington Corporation Model 3WTL-87 with a Worthington Type S turbine drive.

Temperature limits on the turbine bearing lube oil and the pump end bearing, the only two items cooled by the service water, are 180'F and 150'F, respectively.

In the test performed on August 10,

1979, the TDAFW pump was success-fully operated for one hour forty-five minutes with no service water; thus with no reliance on AC power.

For the first thirty minutes, the pump was operated with only a small amount of steam admission. flow to the turbine.

Only a small temperature rise was noted at the affected bearings.

Steam admission flow was then increased, and for the subsequent 75 minutes, the pump was on full recirculation flow (25% of full flow, which is 50% of the minimum safeguards required flow).

Even though the pump was running at less than full capacity, the pump and turbine speeds were the same as which would have been attained at full flow.

Thus, bearing friction loads were comparable.

Also, steam admission flow to the turbine increases only slightly when pump flow is increased, and thus steam heat, addition to the lube oil would be only slightly greater at either minimum safeguards flow or full pump capacity.

It is thus considered that the recircu-lation flow test, which was conducted was representative of a full-flow test.

During the entire test, the pump was monitored and all pertinent parameters remained within acceptable ranges (specifically, the lube oil and bearing reached a final test temperature of about 120'F).

Further, operating parameters were stable over the last fifteen minutes of the test so that the operation could have continued without problems, had it been deemed necessary.

Based on this test, it is our position that the Ginna TDAFW system is operable without reliance on AC power for an acceptably long period of time and that no system changes, either in the short term or the long term, are necessary.

Very truly yours, L.D. White, Jr..

~

~