Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
ML19211D26020 December 1979Inservice Insp Examination Summary from 791203-15 Per IE Bulletin 79-17 & ASME Class 2 Examinations.Describes Examinations Performed on Circumferential Pipe Welds in Sys Identified as Containing Stagnant Oxygenated Borated WaterBoric Acid
Liquid penetrant
ML19260B2287 November 1979Inservice Insp,Examination Summary,791003-16,Insp Period 2, Steam Generator Tube Eddy Current Exam.
ML19323A3441 April 1980Inservice Insp Rept/Exam Summary for Refueling Outage Number 4 on 800102-0204Boric Acid
Liquid penetrant
ML19339A26421 October 1980Inservice Insp Examination Summary, 800818-1013Boric Acid
Liquid penetrant
ML19343B5871 December 1980Inservice Insp Rept for 800902-1013,Refueling Outage 5,Insp Period 2.Discusses Examination of Pressure Retaining Components & Supports of Reactor Coolant & Associated Sys Classified as ASME Class 1 & Class 2Liquid penetrant
ML19344E32528 July 1980Inservice Insp - Examination Summary for Prairie Island Nuclear Generating Plant - Unit 1,800705-18,Insp Period 2, Steam Generator Tube - Eddy Current Examination.
ML19347F30327 April 1981Inservice Insp Rept on 810223-0323.Describes Exam Results of Pressure Retaining Components & Supports of Reactor Coolant, Reactor Pressure Vessel & Bolting of Seismic Supports. Integrity of Sys Has Been MaintainedBoric Acid
Liquid penetrant
ML20010H4683 September 1981Inservice Insp Rept on 810701-13.Describes Exams Performed During Reactor Coolant Pump Maint Outage
ML20012E42922 February 1990Inservice Insp-Exam Summary 900103-0219 Refueling Outage 13,Insp Period 2,Second Interval.
ML20027C19115 September 1982Inservice Insp Rept on 820601-0709.Rept Summarizes Exam Results of balance-of-plant & Eddy Current Exam of Steam Generator TubingBoric Acid
Liquid penetrant
ML20039E08323 December 1981to ASME Code Section XI Inservice Insp & Testing Program & Info Required for NRC Review of Requests for Refief from ASME Code Section XI Requirements.
ML20056C42815 June 1993Rev 0 to Prairie Island Nuclear Generating Plant,Units 1 & 2 IST Program ManualSafe Shutdown
Boric Acid
Loop seal
Stroke time
ML20064J82716 March 1994Refueling Outage Number 16,Outage Dates 931029-1216,ISI Interval 2, Period 3Boric Acid
Nondestructive Examination
VT-2
ML20066C92316 October 1990Plant,Inservice Insp Exam Summary,901029-1002,Refueling Outage 14,Insp Period 2, Second Interval
ML20071D69410 February 1983Inservice Insp - Exam Summary Prairie Island Nuclear Generating Plant - Unit 1 821115 to 830110Boric Acid
Liquid penetrant
ML20072P33225 March 1983Corrected Page 5 of Introduction to Inservice Insp - Exam Summary for Prairie Island Nuclear Generating Plant - Unit 1,
ML20073H78329 September 1994ISI Summary Rept Refueling Outage 16Boric Acid
Nondestructive Examination
VT-2
ML20079E54928 December 1983Inservice Insp - Exam Summary:Prairie Island Nuclear Generating Plant,Unit 2,830829-1001Boric Acid
Liquid penetrant
ML20083D71426 September 1991Refueling Outage Number 14 Outage Dates 910601-910630 Commercial Svc Date 731216 Inservice Insp Interval 2,Period 2Boric Acid
Nondestructive Examination
VT-2
ML20083J03228 December 1983Inservice Insp - Exam Summary,Prairie Island Nuclear Generating Plant,Unit 1,830927-29. Rept Summarizes Safety Injection Sys Boric Acid Suction Line InspBoric Acid
ML20087L39615 March 1984Inservice Insp Exam Summary,831204-23Boric Acid
Liquid penetrant
ML20091J4769 May 1984Inservice Insp - Exam Summary Prairie Island Nuclear Generating Plant - Unit 1,840327-30. Rept Summarizes Circumferential Pipe Welds Containing Stagnant Oxygenated Borated WaterBoric Acid
ML20092L68921 September 1995NSP ISI Summary Rept Prairie Island Unit 2,1995
ML20097G18410 June 1992Inservice Insp Interval 2,Period 3 Summary Rept, for 920220-0315 for Unit 2Boric Acid
Nondestructive Examination
VT-2
ML20107B3788 January 1985Inservice Insp Rept for 841023-1104.On 841021,Unit 1 Began Shutting Down Due to primary-to-secondary Steam Generator Tube Leakage.Westinghouse Provided Necessary Eddy Current Exams & Tube Plugging SvcsHydrostatic
ML20112D68329 May 1996Pings Unit 1 ISI Summary Rept for First Period of Third IntervalBoric Acid
Hydrostatic
Nondestructive Examination
VT-2
ML20114B4513 January 1985Inservice Insp Rept for 840919-22 Re Exams Performed on Circumferential Pipe Welds to Determine If Oxygenated Borated Water Stagnated Inside Welds to Prevent Transgranular Stress Corrosion CrackingBoric Acid
ML20114B6833 January 1985Inservice Insp - Exam Summary,Prairie Island Nuclear Generating Plant - Unit 2,840905-1002Boric Acid
Liquid penetrant
ML20126A34714 December 1992Steam Generator Insp Repts. Following Recent Insp of Unit 1 SGs,21 Tubes Plugged for First TimeBoric Acid
ML20128D7096 May 1985Inservice Insp Rept for 850114-0222.Balance-of-plant & Reactor Pressure Vessel Remote Tool Exams,Eddy Current Exams of Steam Generator Tubing & Safety Injection Line Replacement Exam Results Summarized
ML20128E5881 May 1985Inservice Insp-Exam Summary Prairie Island Nuclear Generating Plant-Unit 1,850114-0222,First 10-Yr Final ReptLiquid penetrant
ML20137P63414 January 1986Inservice Insp Exam Summary,850909-1021,Refueling Outage 9, Insp Period 3,First Interval. Integrity of RCS & Associated Sys MaintainedBoric Acid
Liquid penetrant
ML20137P75014 January 1986Inservice Insp - Exam Summary,850909-1021,Refueling Outage 9,Insp Period 1,Second Interval. Sys Integrity MaintainedBoric Acid
Liquid penetrant
Dissimilar Metal Weld
ML20141D80620 June 1997Nsp,Unit 2 ISI Interval 3,Period 1 Refueling Outage 18,on 970125-0327Boric Acid
Hydrostatic
Nondestructive Examination
VT-2
ML20150D16620 February 1988Inservice Insp - Exam Summary 880104-0210,Refueling Outage 12,Insp Period 2,Second Interval
ML20204F95819 April 1983Rev 8 to ASME Code Section XI Inservice Insp & Testing Program & Info Required for NRC Review of Requests for Relief from ASME Code Section XI RequirementsStroke time
Power Operated Valves
ML20205Q51015 March 1999Inservice Insp Summary Rept Interval 3,Period 1 & 2 Refueling Outage Dates 981109-1229 Cycle 19,970327-981229
ML20206K37325 October 1988Unit 1,Inservice Insp - Exam Summary,880815 to 880914,Refueling Outage 12, Insp Period 2,Second IntervalBoric Acid
Liquid penetrant
Dissimilar Metal Weld
ML20206U91328 May 1986Inservice Insp - Exam Summary,860308-0407,Refueling Outage 10,Insp Period 1,Second IntervalBoric Acid
VT-2
Liquid penetrant
Dissimilar Metal Weld
ML20211C2534 August 1999Unit 1 ISI Summary Rept Interval 3,Period 2 Refueling Outage Dates 990425-990526 Cycle 19 971212-990526Boric Acid
Hydrostatic
Nondestructive Examination
VT-2
ML20211Q65820 January 1987Inservice Insp-Exam Summary for 861020-1119Boric Acid
VT-2
Liquid penetrant
Dissimilar Metal Weld
ML20214U4875 May 1987Inservice Insp Exam Summary,870220-0303,Forced Eddy Current Outage,Insp Period 1,Second IntervalBoric Acid
Liquid penetrant
Dissimilar Metal Weld
ML20236E86326 June 1987Inservice Insp - Exam Summary,870407-0514,Refueling Outage 11,Insp Period 1,Second IntervalB.5.b Mitigating Strategies
Liquid penetrant
ML20248C10728 April 1989Inservice Insp - Exam Summary,890320-0425,Refueling Outage 13,Insp Period 2, Second IntervalBoric Acid
B.5.b Mitigating Strategies
Liquid penetrant
ML20248L39310 March 1998ISI Summary Rept Interval 3,Period 1 & 2 Refueling Outage Dates 971018-971212 Cycle 18,960303-971212Boric Acid
Hydrostatic
Nondestructive Examination
VT-2