Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
ML17299A30910 May 1985Ro:On 850505,plant Security Sys Did Not Return to Svc as Expected After Planned Electrical Outage.Security Compensatory Measures Established Per Station Security Plan. Event Determined Not Reportable Under 10CFR73.71
ML17299A35624 May 1985Special Rept:On 850424,72-h Action Statement for Operability of Containment Area Radiation Monitors RU-148 & RU-149 Exceeded.Justification for Interim Operation Submitted by Licensee.Detectors Will Be Installed by 850731
ML17299A36725 May 1985Special Rept:On 850425,diesel Generator a Determined Inoperable Due to Start Failure While Testing Oscillographic Device.Caused by Oil in Control Air Sys.Fuel Rack Cylinder Shaft Thoroughly Cleaned.Generator Tested Satisfactorily
ML17299A38410 June 1985Special Rept Re 850509 Failure of Diesel Generator to Start. Caused by Failure of turbo-charger Manifold Temp Control Valve in Vent to Atmosphere Position & Major Starting Air Sys Leak.Control Air Supply Plugged to Temp Control ValvesTemporary Modification
ML17299A4135 June 1985Special Rept:On 850426,72 H Action Statement for Inoperability of Condenser Evacuation Sys high-range Noble Gas Activity Monitor Exceeded.Caused by Failure of Associated Sample Pump.Setpoint Adjusted
ML17299A42925 June 1985Special Rept:On 850526,containment Atmosphere Radiation Monitor RU-1 Particulate Channel Declared Inoperable.Caused by Misunderstanding of Channel Operation.Radiation Protection Dept Procedures RevisedGrab sample
ML17299A46519 July 1985Special Rept 1-SR-85-013:on 850618,diesel Generator B Failed to Start within 10 Acceptance Criteria of Surveillance Test 41ST-1DG02.Cause Not Determined.Valves Inspected & Cleaned
ML17299A4957 August 1985Special Rept 1-SR-85-014:on 850708,containment High Range Monitor RU-149 Declared Inoperable Due to Erroneous Readings.Caused by Exceeding 72 H Action Statement for Operability of Monitor.Circuit Board Replaced
ML17299A70825 October 1985RO-1-SR-85-025:on 851024,reactor Trip Resulted from Low Steam Generator Level Signal Following Turbine Trip.Caused by High Pressure Pulse Initiated by Rapid Closure of Turbine Throttle.Safety Injection Signal Reset
ML17299A70925 October 1985Special Rept 1-SR-85-018:on 850925,condenser Evacuation Sys High Range Monitor RU-142 Inoperable for More than 72 H. Caused by Random Loss of Stored Data.Schedule Being Developed to Resolve Problem
ML17299A76415 November 1985Special Rept 1-SR-85-024 & Suppl to Special Rept 1-SR-85-018:on 851013,condenser Evacuation Sys Radiation Monitor Noble Gas Channel Declared Inoperable.Flow Rate Being Estimatd Every 4 H Per Tech Spec Table 3.3-13
ML17299A8562 December 1985Special Rept (1-SR-85-027):on 851030,diesel Generator a Failed to Start from Control Room While Performing Surveillance Test Procedure 41ST-1DG01.Caused by Faulty Fiber Optic Cable.Cable Replaced
ML17299A8572 December 1985Special Rept 1-SR-85-030:on 851028,containment high-range Radiation Monitor RU-149 Inoperable for More than 72 H. Caused by Spurious High Radiation Alarms Coincident W/ Spurious Detector Failure Alarms.Addl Rept by 851230
ML17300A27017 July 1986Special Rept 1-SR-86-079:on 860712,Channel a & B Steam Generator 2 Tripped on Low Reactor Coolant Flow,Initiating Reactor Trip.Cause Under Investigation.Ler Will Be Submitted within 30 Days
ML17300A39223 June 1986Corrected Special Rept 1-SR-86-071:on 860513,Unit 1 Steam Generator 1A & 2B Sensors Experienced Excessive Alarms.On 860616,Unit 2 Steam Generator 1A Sensor Emitted Spurious Alarms.Caused by Improper Alarm Setpoints
ML17300A71220 March 1987Ro:On 861104,MSIV SGE-UV-1709 Opened,Causing Cooldown of Rcs.Valve Closed & Plant Stabilized.Occurrence Could Not Be Duplicated.No Problems W/Valve Identified.Removal of Fast Open Circuitry After Installation of Valves VerifiedStroke time
ML17300A74630 March 1987Special Rept 1-SR-87-014:on 870212,containment Bldg Area Radiation Monitor RU-148 Declared Inoperable Due to Implementation of Plant Change Package 85-01-SQ-039-00. Monitor RU-148 Returned to Svc on 870306
ML17300A74830 March 1987Special Rept 2-SR-87-007:on 870312,time Limit for Restoring Channel of Reactor Vessel Water Level Instrumentation Exceeded.Cause of Inoperability Under Investigation.Channel Expected to Be Returned to Svc at Next Refueling OutageReactor Vessel Water Level
ML17300A7511 April 1987Special Rept 1-SR-87-013:on 870130,while in Mode 5,fuel Bldg Ventilation Sys Low Range Monitor RU-145 Declared Inoperable Due to Alarms.On 870304,while in Mode 3,monitor RU-146 Declared Inoperable.No Cause Identified
ML17300A75326 March 1987Special Rept 1-SR-87-011:on 870228,72 H Limit for Inoperability of High Range Noble Gas Activity Monitor RU-144 Was Exceeded.Caused by Removal of RU-144 for Testing for Associated RU-143 Monitor.Monitor Returned to Svc
ML17300A75430 March 1987Special Rept 1-SR-87-010:on 870224,condenser Evacuation Sys high-range Radiation Monitors Declared Inoperable When Continuous Low Flow Alarms Received.Caused by Water in Sample Tube.Boards Replaced & Monitors Retested
ML17300A75530 March 1987Special Rept 1-SR-87-012:on 870302,following Cleaning of Contacts,Diesel Generator a Failed to Start in Emergency Mode.Caused by Defective Power Resistor.Root Cause of Failure Data Sheet Initiated & Further Action Will Be Taken
ML17300A75630 March 1987Special Rept 2-SR-87-006:on 870309,radiation Monitor RU-139B Continuously Alarmed Due to Erroneous High Radiation Levels. Caused by Broken Wire in Microcomputer Preamplifier. Preamplifier Replaced & Root Cause of Failure Initiated
ML17300A76130 March 1987Special Rept 1-SR-87-016:on 870303,Tech Spec 3.3.3.6 Action 32 Entered Due to Inoperability of Both Channels of Reactor Vessel Water Level Instrumentation.On 870305,time for Restoring Channels to Svc Exceeded.Cause UnknownReactor Vessel Water Level
ML17300A76230 March 1987Special Rept 2-SR-87-004:on 870305,low & High Range Noble Gas Activity Monitors Inoperable for More than 72 H.Caused by Failure of Flow Control Valve Coupling to Perform Intended Function.Coupling Replaced
ML17300A7643 April 1987Special Rept 2-SR-87-005:on 870308,high-range Noble Gas Activity Monitor RU-146 Inoperable for Greater than 72 H. Caused by Random Cycling Alarms to Microcomputer Software. Plant Change Request PCR 87-13-SQ-020 Initiated
ML17300A77617 April 1987Special Rept 1-SR-87-015:on 870408,30-day Action Statement for Operability of Seismic Monitoring Sys Exceeded.Caused by Ribbon Cable Wire Separating from Connector.Cable RepairedEarthquake
ML17300A8254 May 1987Special Rept 2-SR-87-008:on 870406,condenser Evacuation Sys Radioactive Gaseous Effluent monitors,low-range RU-141 & high-range RU-142 Declared Inoperable for Greater than 72 H. Water Found in RU-141 Due to Holes in Detector Mylar
ML17300A85515 May 1987Special Rept 2-SR-87-012:on 870416,Containment Bldg Atmosphere RU-1 Declared Inoperable Due to Ground Identified in Monitor.Check for Grounds Conducted But No Grounds Found. Functional Test Performed & Monitor Returned to Operation
ML17300A86018 May 1987Special Rept 1-SR-87-017:on 870419,containment Bldg Area Radiation Monitor (RU-149) Declared Inoperable Due to Spurious Detector Failure Alarms.Cause Undetermined. Surveillance Testing Conducted & RU-149 Restored
ML17300A86718 May 1987Special Rept 2-SR-87-013:on 870421,process Monitor RU-1 Inoperable for More than 72 H Due to Frequent Failure Alarms.Caused by Voltage Spikes on Grounding Sys.Mod Initiated to Replace Moving Filter Assembly W/Fixed Filter
ML17300A86822 May 1987Special Rept 2-SR-87-014:on 870426,radioactive Gaseous Effluent Monitors RU-144 Inoperable for More than 72 H. Caused by Test Performance & Subsequent Gm Detector Failure. Monitor Will Be Returned to Svc by 870529Temporary Modification
ML17300A94122 June 1987Special Rept 2-SR-87-018:on 870523,high & Low Range Noble Gas Activity Monitors Inoperable for Greater than 72 H. Caused by Defective Amplifier Displacement Card Which Caused Low Readings.Card Replaced
ML17300A9793 August 1987Special Rept 2-SR-87-023:on 870717,condenser Vacuum Pump/ Gland Seal Exhaust Monitors Inoperable for Greater than 72 H.Caused by Broken Directional Wire.Mod/Design Enchancement Currently Being Evaluated.Monitors Restored
ML17300B0371 September 1987Special Rept 2-SR-87-022:on 870828,unusual Event Declared Due to Release in Excess of 6.62 E-4 Mci Per Cubic Centimeter.Cause Under Investigation.Corrective Action Will Be Developed Based on Investigation Results
ML17300B06814 October 1987Special Rept 2-SR-87-024:on 870915,fuel Bldg B Vent Exhaust Low & High Range Monitors Declared Inoperable & Placed in Bypass Due to Problems W/Recurrent Voltage Spiking & False Background Readings.Engineering Evaluation UnderwayGrab sample
ML17300B13414 December 1987Special Rept 1-SR-87-025:on 871205,insp Resulted in Plugging of II Tubes in Steam Generator 1 & One Tube in Steam Generator 2
ML17300B13714 December 1987Special Rept 1-SR-87-024:on 871120,plant Vent high-range Gaseous Activity Monitor RU-144 Inoperable for More than 72 H.Caused by Detector Aging.Detector Replaced & Calibr
ML17300B15624 December 1987Special Rept 2-SR-87-029:on 871126,high Range Noble Gas Monitor (RU-142) Found Inoperable for More than 72 H.Caused by Water in RU-141 Sample Line.Moisture Traps Will Be Installed in Sample Lines During Next Refueling OutageGrab sample
ML17300B18225 January 1988Special Rept 3-SR-87-006:on 880117,loose-part Instrumentation Inoperable for More than 30 Days.Calibr Will Be Performed by End of First Outage.Periodic Audio Check Will Be Performed Until Instrument Operable
ML17300B20916 February 1988Special Rept 1-SR-88-001:on 880122,72 H Limit for High Range Noble Gas Monitor RU-142 Inoperability Exceeded.Caused by Defective Low Voltage Power Supply for RU-142 Microcomputer. Replacement Power Supply Installed & Calibr
ML17300B23128 December 1989Special Rept 2-SR-89-010:on 891124,Tech 3.3.1,Action 28 Violated.Caused by 7-day Limit of Initiation of Preplanned Alternate Sampling Program Exceeded.Preventive Maint Completed.Leaking Valves Replaced & Pump Ordered
ML17300B23221 December 1989Suppl 1 to Special Rept 3-SR-89-003:on 890215,72 H Limit for Inoperability of Condenser Evacuation Sys high-range Effluent Monitor (RU-142)exceeded.Design of Subj Evacuation Sys Reviewed & Addl Electric Resistance Heating InstalledGrab sample
ML17300B23323 December 1989Suppl to Special Rept 3-SR-89-006:on 890812,radiation Monitors RU-145 & RU-146 Exceeded 72 H Limit for Returning Monitors to Operable Status.Caused by Malfunction of Monitor RU-146 Resulting in Loss of Capability to Monitor Effluents
ML17300B23423 December 1989Special Rept 2-SR-89-008:on 891124,gaseous Effluent Monitors RU-142 & RU-144 Taken Out of Svc & Declared Inoperable for More than 72 H to Implement Site Mod.Caused by Use of Rectifier in Power Supply Circuit.Site Mod Completed
ML17300B23928 December 1989Special Rept 2-SR-89-004,Suppl 1:on 890330 & 0406,PASS Inoperable for More than 7 Days.Caused by Planned Isolation of Demineralized Water Supply to Pass.On 890331,temporary Mod Approved to Isolate Demineralized Water SysTemporary Modification
ML17303A4268 June 1987Special Rept 2-SR-87-015:on 870509,containment Area Monitor Channel a Inoperable for Greater than 72 H.Caused by Repairing Single Channel Area Monitor Board.Analysis Begun to Determine Cause of Board Failure on 870506
ML17303A4278 June 1987Special Rept 2-SR-87-016:on 870509,radioactive Gaseous Effluent Monitor Exceeded 72 H Limit for Operability.Caused by Maint of Low Flow Alarm.Surveillance Test Performed & Monitor Declared Operable on 870512
ML17303A4288 June 1987Special Rept 1-SR-87-019:on 870504,radiation Monitor Declared Inoperable Due to Spurious Detector Failure Alarms. Cause of Alarms Unknown.Monitor Returned to Operability After Completion of Surveillance Testing
ML17303A4298 June 1987Special Rept 3-SR-87-001:on 870514,high Range Noble Gas Activity Monitor RU-144 Inoperable for Greater than 72 H. Caused by Low & High Range Plant Vent Monitors Being Taken Out of Svc on 870511 for Implementation of Change Package