ML19317F342 | 4 April 1978 | LER 78-003/03L-0:on 780301,during Performance Test,Control Rod Group 5 Experienced Momentary Loss of Power.Cause Undetermined.Mod to Increase Rod Control Power Source Reliability Planned for All Units | |
ML19322C160 | 3 February 1978 | LER 78-001/03L-0:on 780105,Valve FDW-108 Failed to Close After Sample Removal.Similar Valve Failures Occured Previously.Probably Caused by Inability to Withstand environ.FDW-1-6,108 Replaced W/Appropriately Designed Valve | |
ML19338D587 | 19 September 1980 | LER 80-014/03L-0:on 800822,concentrated Boric Acid Storage Tank Pump Removed from Svc Due to Oil & Flange Leaks.Caused by Torn Oil Seal,Worn Worm Gear,Bad Flange Gasket & Stuck Pressure Relief Valve.Items Replaced | Boric Acid Shutdown Margin |
ML19340A136 | 21 April 1978 | LER 78-010/03L-0:on 780322,no Flow Found Through B LPIS Cooler During Performance Test.Caused by Broken Valve Position Indicator.Valve Opened & Indicator Repaired | |
ML19340A150 | 19 April 1978 | LER 78-009/03L-0:on 780320,valve HP-24 Failed to Open When Manually Actuated During Performance Test.Caused Probably by Dirt on Operator Contacts.Contacts Cleaned & Valve Operated Properly | |
ML19340B937 | 6 November 1980 | LER 80-022/01T-0:on 801011,four Holes Were Knocked in Fire Barrier Between Cable Spread Room & Turbine Bldg W/O Establishment of Hourly Fire Watch.Caused by Failure to Provide Proper Notificaion.Hourly Fire Watch Established | Fire Barrier Hourly Fire Watch |
ML20005A314 | 9 April 1981 | LER 81-004/03L-0:on 810304,motor Driven Emergency Feedwater Pump 2B Was Declared Inoperable Due to Arcing in Motor.Cause Unknown.Motor Was Disassembled & Failure Found in Coil Slot | |
ML20005A424 | 10 March 1981 | LER 80-040/01T-0:on 801226,removable Instrument Assembly 40 Count Rate Increased,Apparently Due to Leak in once-through Steam Generator Tube.Caused by High Cycle Fatigue.Tube Replaced.Leak Procedure Implemented | |
ML20005A793 | 25 February 1981 | LER 81-002/01T-0:on 810211,electrical Penetration EMV-2 Could Not Be Pressurized.Caused by Leak at Interior Bushing. Penetration to Be Repaired or Replaced During Next Outage | |
ML20005A804 | 24 February 1981 | LER 81-003/03L-0:on 810125,dc Input Fuse in 1DID Vital Inverter Blew,Causing Inverter to Lose Power source.1DIB Inverter Tripped When Ac Output Breaker Apparently Opened. 1DID Trip Caused by Blown Fuse.Cause of 1DIB Trip Unknown | |
ML20005A824 | 13 March 1981 | LER 81-004/03L-0:on 810212,primary Level Indication for Elevated Water Storage Tank Was Declared Inoperable Following Low Water Level Alarms.Caused by Loose Connectors on Air Compressor Starter Terminals.Connections Tightened | |
ML20005A872 | 9 March 1981 | LER 81-005/01T-0:on 810222,low Power Injection Check Valve Discovered Leaking Excessively During Intersystem LOCA Leak Test.Caused by Buildup of Crud in Pivot Gap Area.Disc Hinge & Hinge Pin Replaced.Crud to Be Analyzed | |
ML20009C091 | 13 May 1981 | LER 81-006/03X-1:on 810409,valve 2PR-8 Failed to Open During on Line Engineering Safety Testing.Caused by Faulty Valve Operator Diaphragm.Valve 2PR-8 Repaired & Verified Operable | |
ML20009C098 | 19 February 1981 | LER 80-016/03L-1:on 801123,fire Detectors String B-2 Went Into Alarm Condition.Caused by Dust Buildup in Detector. Detector Cleaned & Verified Operable | |
ML20009C107 | 5 June 1981 | LER 81-009/03L-0:on 810507,containment Isolation Valve 3CS-6 Was Discovered in Intermediate Position,Resulting in Loss of Containment Integrity.Cause Undetermined.Valve 3CS-6 Verified Operable | |
ML20009C115 | 17 June 1981 | LER 81-011/03L-0:on 810518,safety-related Mechanical Snubber Was Discovered Inoperable During Visual Insp.Caused by Ball Screw Shaft of Snubber Being Slightly Scored,Prohibiting Ball Bearings from Running Smoothly.Snubber Replaced | |
ML20009C122 | 19 June 1981 | LER 81-001/03X-1:on 810120,discovered That Low Pressure Svc Water Was Not Flowing to HPI Pump 2A.Caused by Blockage Due to Crud Buildup.Portions of Carbon Steel Piping Will Be Replaced W/Stainless Steel | |
ML20009C136 | 10 June 1981 | LER 81-003/01X-1:on 810226,steam Generator B Was Pressurized to 550 Psig.Caused by Procedural Deficiency.Valves Opened to Lower Once Through Steam Generator Pressure.Condensate & Feedwater Procedure Will Be Revised | |
ML20009C148 | 10 June 1981 | LER 81-008/01T-0:on 810513,loss of Valve Position Noticed. Valve CCW-8 Determined to Be Electrically Inoperable.Caused by Open Circuit in Several Conductors in Control Cable. Control Cable Replaced & Valve Electrically Cycled | |
ML20009C154 | 16 June 1981 | LER 81-010/03L-0:on 810517,broken Airline to Valve 3LPSW-525 Was Discovered.Caused by Breakage of Brass Nipple Between Air Supply Isolation Valve & Accumulator Tank.Brass Nipple Replaced | |
ML20009C158 | 4 March 1981 | LER 81-005/01T-0:on 810318,four Closure Studs on Reactor Coolant Pump 2A2 Had Corrosion Wastage in Pump Closure Area. Caused by Leakage from Pump Closure Gaskets.Stud 20 Replaced.Studs 1,2 & 3 Left in Place | Time of Discovery |
ML20009C181 | 5 June 1981 | LER 81-012/03L-0:on 810506,turbine Driven Emergency Feedwater Pump Oil Sump Was Discovered Empty.Cause Unknown. Pump Control Switch Placed in Locked Out Position to Prevent Automatic Start of Pump.Oil Level Restored | |
ML20009C213 | 8 May 1981 | LER 81-006/03L-0:on 810409,valve 2PR-8 Failed to Open During on-line Insp.Caused by Faulty Valve Operator Diaphragm.Valve Repaired & Verified Operable | |
ML20009C234 | 8 June 1981 | LER 81-008/03L-0:on 810508,solenoid Valve for 2FDW-316 Stuck in Manual Position,Disabling Automatic Level Control of B Steam Generator from Emergency Feedwater Sys.Valve Replaced Per Procedure | |
ML20009C313 | 8 May 1981 | LER 81-007/01T-0:on 810410,fire Barrier Door for West Penetration Room Was Inoperable W/O Proper Fire Watches Maintained.Caused by Personnel Error.Individual Involved Counseled Re Importance of Communication | Fire Barrier |
ML20009C323 | 15 May 1981 | LER 81-009/03L-0:on 810415,during Low Pressure Svc Water Pump Periodic Test,Valves 2LPSW-19 & 2LPSW-21 Were Closed Resulting in RB Rbcu Being Out of Svc.Caused by Personnel Error.Valve 2LPSW-19 Opened & Personnel Counseled | |
ML20009C368 | 12 March 1981 | LER 81-003/01T-0:on 810226,B Steam Generator Was Pressurized to 550 Psig.Caused by Procedural Deficiency. Once-through Steam Generator Pressure Lowered.Procedures for Opening Startup Block Valves Will Be Revised | |
ML20009F501 | 14 July 1981 | LER 81-013/01T-0:on 810630,backup Function of Isolating & Transfer Diodes in Instrumentation & Control Sys Disabled on All Channels on All Units.Caused by Misinterpretation of Tech Specs.Proposed Tech Spec Change Initiated | |
ML20009F513 | 2 July 1981 | LER 81-010/03L-0:on 810602,turbine Driven Emergency Feedwater Pump Declared Inoperable.Caused by Governor Valve Sticking in Open Position Due to Sys Contamination.Linkage Pin Removed,Governor Valve Freed & Stem Cleaned | |
ML20009F909 | 23 July 1981 | LER 81-011/01T-0:on 810715,during Visual Exam of Reactor Vessel Internal Components,Thermal Shield Bolts & Guide Block Discovered Missing.Cause Not Determined.Program Defined to Determine Cause & Effect Repairs | |
ML20009G087 | 26 June 1981 | LER 81-013/03L-0:on 810528,1-inch Breach Discovered in 3-h Fire Barrier in Floor of Control Room Outside Shift Supervisor Ofc.Cause Undefined Due to Breach Being Covered Since Const of Control Room | Fire Barrier |
ML20009G471 | 22 July 1981 | LER 81-009/03L-0:on 810622,during Normal Operations,Startup Transformer CT-1 Locked Out.Cause Not stated.CT-1 Transformer & Bus Work Checked & Protective Relaying Checked for Malfunction Prior to Return to Svc | |
ML20009G633 | 24 July 1981 | LER 81-012/03L-0:on 810624,discovered safety-related Hydraulic Snubber on Atmospheric Dump Line B Was Broken at Rod Eye.Caused by Vibration.Snubber Repaired | Earthquake |
ML20009G774 | 24 July 1981 | LER 81-012/03L-0:on 810624,valve 3PR-8 Failed in Closed Position,Isolating Radiation Monitors 3 RIA-47,48 & 49. Caused by Ruptured Diaphragm in Air Operator on Valve. Diaphragm Replaced | |
ML20010D237 | 17 August 1981 | LER 81-015/01T-0:on 810720,while Attempting to Perform Engineered Safeguard Periodic Test,Low Pressure Injection Pump 3-B Failed to Start.Caused by Personnel Error.Pump Motor Bearings Replaced & Personnel Counseled | |
ML20010E778 | 25 August 1981 | LER 81-015/01T-0:on 810811,modules in Reactor Protection Sys Were Found to Have Errors Larger than Originally Calculated Values.Errors re-evaluated & Setpoints Changed to New Settings | |
ML20010F451 | 31 July 1981 | LER 81-014/01L-0:on 810717,A & B High Pressure Svc Water Pumps Discovered W/O Control Power Indication & Elevated Water Storage Tank Showed Zero Level.Caused by Control Breaker Source a & B Breakers Being Open & Blown Fuse | |
ML20010F828 | 4 September 1981 | LER 81-011/03L-0:on 810806 & 07,RCS Subcooling Margin Monitor Was Inoperable & Backup Method Unavailable.Caused by out-of-svc Unit 2 Operator Aid Computer Due to Malfunction of AGRA2 Group Relay Board & Matrix Card | |
ML20010H922 | 14 September 1981 | LER 81-013/03L-0:on 810815,reactor Bldg Spray Pump 2A Declared Inoperable Due to Oil Leak on Bearing Oil Reservoir.Caused by Loose Piping Allowing Leakage.Reservoir Refilled W/Oil | |
ML20010J023 | 17 September 1981 | LER 81-016/01T-0:on 810903,magnetic Particle Testing on 1A2 Reactor Coolant Pressure Seal Housing Bolts Revealed Linear Indications.Bolts W/Rejectable Indications Will Be Replaced | |
ML20011A747 | 20 October 1981 | LER 81-018/03L-1:on 810911,safety-related Battery Surveillance Procedures Found Out of Compliance W/Revised Tech Spec 4.6.9.Caused by Personnel Failure to Identify Necessary Procedure Changes.Procedures Revised | |
ML20023C446 | 22 April 1983 | LER 83-012/01T-0:on 830408,emergency Discharge Valve to Keowee Tailrace CCW-8 Opened W/O Command,Rendering Condenser Circulating Water Emergency Discharge Sys Inoperable.Caused by Shorted Conductor.Conductor Replaced | |
ML20023C711 | 5 May 1983 | Updated LER 83-012/01T-1:on 830421,emergency Discharge Valve to Keowee Tailrace CCW-8 Opened W/O Command,Rendering Condenser Circulating Water Emergency Discharge Sys Inoperable.Caused by Component Failure | |
ML20024B988 | 30 June 1983 | LER 83-008/03L-0:on 830531,motor Driven Emergency Feedwater Pump Became Inoperable When Power Removed from Circuitry for Repair of Automatic Initiation Switch 2PS-388.Caused by Component Failure.Switch Replaced & recalibr.W/830630 Ltr | |
ML20024C423 | 24 June 1983 | LER 83-011/03L-0:on 830525,lockout Indication Received for Startup Transformer CT3.Cause unknown.CT3 Energized. W/830624 Ltr | |
ML20027B462 | 10 September 1982 | LER 82-009/01T-0:on 820804,during Refueling Insp of Reactor Coolant Pump,Five Closure Studs Found Degraded in Size Below Tech Spec Min.Caused by Boric Acid Corrosion Due to Closure Gasket Leakage.Studs Replaced | Boric Acid |
ML20027B839 | 21 September 1982 | LER 82-011/03L-0:on 820822,erratic Indication Observed on Channel a Borated Water Storage Tank Level Instrumentation. Caused by Boiling Water in Level Transmitter Line.Heat Tracing Disconnected & Transmitter Lines Refilled | |
ML20027D633 | 28 October 1982 | LER 82-018/01T-0:on 821014,three of Six Installed Safety Valves Determined to Have Degraded Performance Based on Valve Ring Settings.Cause of Difference in Ring Settings Unknown.Valves Reset Using EPRI Tested Settings | |
ML20027D854 | 3 November 1982 | LER 82-011/03L-0:on 821004,while Inspecting Snubber Installed on 821002,mechanic Found Snubber Inoperable.Caused by Misreading of Hanger Sketch.Snubber Removed,Tested & Reinstalled | |
ML20028D177 | 6 January 1983 | LER 82-019/03L-0:on 821207,valve 1HP-25 Failed to Open Remotely During Operational Valve Function Test.Caused by Component Failure.Valve Manually Cracked Open,Cycled & Stroke Tested |